Maytag MSD2357HEB Specifications

Service Specifications
Side-by-Side RefrigeratorTechnical Information
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
3. Release the refrigerator door light switch.
4. The control will display Fd to confirm entry into the Forced Defrost Mode.
Freezer
ASD2626HEB
ASD2626HES
ASD2628HEB
ASD2628HES
ASD2626HEB0, ASD2626HEQ
ASD2626HES0, ASD2626HEW
ASD2628HEB0, ASD2628HEQ
ASD2628HES0, ASD2628HEW
Due to a possibility of personal injury or property damage, always contact an authorized technician for
service or repair of this refrigerator.
!
Refrigerator
F
CAUTION
All safety information must be followed as provided in Service Manual 16022689.
key once more. The unit is off and in the Defrost Mode.
5. Entry is confirmed by pressing the Refrigerator Down
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will
remain in its current position)
6. The control will default to the short run period test as shown here
Freezer
Refrigerator
S
Note: You can toggle between the (S)hort and (L)ong test mode by pressing the Refrigerator UP
Long Test mode is used for factory test and should not be used in the field.
Freezer
Key.
!
Refrigerator
down Key once.
7. Once the desired mode is displayed, confirm the forced defrost by pressing the Refrigerator
The defrost will begin immediately and the display will return to a normal operating display with set point values.
Freezer
Refrigerator
4
4
Kw/24 hr ±0.4
Ambient °F
26 cu ft
Service Test Mode:
1. Hold the refrigerator door light switch closed.
70°
1.2
90°
1.85
110°
2.6
No-Load Performance, Controls in Normal Position
Refrigerator Center
Compartment
Percent Run Time
Average Food
Cycles/24 hr
±10%
Temperature ±3°F
±25%
70°
35
90°
55
110°
75
70°
24
90°
24
110°
19
70°
37
90°
39
110°
42
Freezer Compartment
Average Food
Temperature ±3°F
70°
0
90°
0
110°
-2
Temperature Relationship Test Chart
8. Close the Refrigerator door(s). You are in the defrost mode
Note: Forced Defrost mode can be exited at any time prior to step 7 by closing the Refrigerator Door(s).
The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode
by performing the following sequence of events
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
L
2. Press the Refrigerator Temperature Up
ASD2626HEQ0,
ASD2626HEW0,
ASD2628HEQ0,
ASD2628HEW0
Ambient °F
26 cu ft
Evaporator
Outlet
±3°F
70°
90°
-15
-15
Evaporator
Inlet
±3°F
70°
90°
-16
-16
Suction Line
±7°F
70°
72
90°
98
Average Total
Wattage ±10%
70°
132
90°
138
Suction
Pressure
±2 PSIG
70°
6"(Vac.)
90°
0
Head Pressure
± 5 PSIG
70°
87
Schematic
keypad 3 times consecutively.
Note: The 3 Keystrokes must be done consecutively and within 10 seconds.
3. Release the refrigerator door light switch.
4. The control will display SE to confirm entry into the service mode.
Freezer
Refrigerator
E
S
5. Entry to the Service Menu is confirmed by pressing the Refrigerator Up
6. The control will display its software version for 3 seconds.
Freezer
key once more.
Refrigerator
2
5
7. Following the software revision display the freezer display will read the first test number in the
diagnostic tree. The refrigerator display will be blank
Freezer
Refrigerator
1
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will
remain in its current position)
8. You are now in the SERVICES TEST operational mode and may use the diagnostic tests
The Service Test Mode can be exited at any time by closing the Refrigerator Door(s).
April 2004
© 2004 Maytag Services
4
16023095
April 2004
© 2004 Maytag Services
1
16023095
90°
137
Component Specifications
!
Service Specifications
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Programming Mode:
Component
Specifications all parts
115VAC/60HZ unless noted
Compressor run capacitor
Volt .....................................................
Capacitance ......................................
Compressor
BTUH .................................................
Watt ...................................................
Current Lock rotor ..............................
Current Full load ................................
Resistance Run windings...................
Resistance Start windings..................
220 VAC
15 µfd ± 10%
905 BTUH
60 Hz / 153 watts
19.0 amps± 15%
1.26 amps± 15%
3.33 ohms± 15%
4.28 ohms± 15%
Electric damper control
Maximum closing time
Temperature Rating
RPM
36 seconds
20°F- 110°F
1
Thermistor
Temperature
77°F....................................................
36°F ...................................................
0°F......................................................
Resistance
10,000 ohms± 1.8%
29,500 ohms± 1.0%
86,300 ohms± 1.8%
Rotation (facing end opposite shaft)
RPM
Watt....................................................
Current ...............................................
Clockwise
1250 RPM
4.2 watts±15%@115VAC
0.63 amps± 15%@115VAC
Rotation (facing end opposite shaft)
RPM……………………………………
Watt…………………………………….
Note: Fan blade must be fully seated
on shaft to achieve proper airflow.
Clockwise
2800 RPM
5.9 ±15% watts@115VAC
Overload/Relay
Ult. trip amps @ 158°F (70°C) ...........
Close temperature ...........................
Open temperature ............................
Short time trip (seconds)....................
Short time trip (amps @77°F (25°C) ..
2.67 amps± 15%
142°F ±9°F
284°F ±9°F
10 seconds ±5
11 amps ±2amps
Thermostat (Defrost)
Volt ....................................................
Watt ...................................................
Current ...............................................
Resistance across terminals:
Above 42°F ±5°..................................
Below 12°F ±7° ..................................
Volt.....................................................
Wattage..............................................
Resistance .........................................
120/240 VAC
495 watts
5.8/2.9 amps
Control board
Volt.....................................................
120VAC, 60 HZ
See Control board troubleshooting section
Auger Motor
Rotation (facing end opposite shaft)
Water Valve (Primary)
Water Valve (Secondary)
Light switch
RPM ...................................................
Watts
Watts
Type……………………………………..
Volt………………………………………
Current…………………………………..
Power to blue and white is clockwise. Power to
orange and white is counterclockwise
17± 3 RPM
Brown side 35w,Yellow side 20w
Brown side 35w,Yellow side 20w
SPST NC
125/250 VAC
8/4 amps
Type……………………………………..
Volt………………………………………
Current…………………………………..
Resistance across leads ....................
SPDT NO/NC
125/250 VAC
8/4 amps
101ohms ± 10%
Condenser motor
Evaporator fan motor
Evaporator heater
Light switch / Interlock
Solenoid (Ice Chute)
April 2004
© 2004 Maytag Services
Note: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Open the Fresh Food door and hold the Fresh Food door light switch closed while pushing the Freezer
Temperature Down
Key pad 3 times consecutively.
Note: The 3 Keystrokes must be done consecutively and within 10 seconds.
2. Release the Fresh Food door light switch.
3. The control will display PE to confirm entry into the programming mode.
Freezer
P
4. Entry is confirmed by pressing the Freezer Down
E
key once more.
Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will
remain in its current position)
5. The control will display the current Program Code. This value should be validated with the Program Code
printed on the unit serial plate.
Freezer
2
Refrigerator
5
Note: If the Program Code is correct, the Programming Mode is exited by closing the Refrigerator door(s).
6. To set the desired Program Code number press the Freezer and Refrigerator UP
keys. The
corresponding digit will be advanced with each key press.
7. Once the desired Program Code is displayed, press the Freezer DOWN
Key until the Program Code
begins flashing indicating it has been saved.
Note: If you attempt to enter an invalid Program Code the control will not save the new code, but will flash the old
code and this will be displayed. (The unit will NOT run with a Program Code of 00).
8. Once the Program Code has been saved the Programming Mode is exited by closing the Refrigerator
door(s). If the new code is incorrect this process should be repeated after closing the Refrigerator door(s).
The Programming mode can be exited at any time by closing the Refrigerator Door(s).
Open
Closed
115 VAC
450 ±5% watts @ 115VAC
29 ±7.5% ohms
2
Refrigerator
Defrost Operation:
The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by
monitoring the length of time the defrost heater is on.
After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours.
Note: Once unit is ready to defrost there is a 4 minute wait time prior to the beginning of the defrost cycle.
Optimum defrost is 15 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted from
the previous defrost interval. Each minute the thermostat opens prior to optimum defrost, it extends the next defrost
interval 1 hr. When defrost thermostat opens there is a 4-6 minute drip time before compressor restarts or Control
Board will terminate defrost at 25 minutes if defrost thermostat has not opened and will reset the defrost interval to the
8 hr. minimum setting.
4 hours of continuous compressor run resets the next defrost interval to 8 hours and will initiate a defrost, if 8 hours of
compressor run time has also occurred.
Forced Defrost Mode:
Power up Refrigeration mode will occur unless both the cold control and defrost terminator are open, in that case the
defrost mode will occur for 2 minutes.
The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost
Mode by performing the following sequence of events:
16023095
1. Hold the refrigerator door light switch closed.
keypad 3 times consecutively.
2. Press the Refrigerator Temperature Down
Note: The 3 keystrokes must be consecutive and within 10 seconds.
April 2004
3
© 2004 Maytag Services
16023095
Wiring Diagram
Service Specifications
!
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Service Test 1 – Defrost Thermostat & Defrost Circuit Test
When selected this test will display the state of the defrost thermostat. In order to perform this test the defrost heater will
be energized. The test is activated and deactivated using the Refrigerator Up
key. Once activated, this test must be
de-activated to move to another test number. The Freezer Up
/ Down
keys allow selection of the test to be
performed.
This test also allows observation and measurement of proper defrost function. You can observe defrost heat and voltages
while the test is activated.
Freezer
Refrigerator
O
1
DEFROST THERMOSTAT OPEN
Freezer
Refrigerator
1
S
DEFROST THERMOSTAT SHORTED (CLOSED)
Service Test 2 – Compressor/Condenser Fan Test
When selected and activated this test will operate the Compressor/Condenser Fan circuit. You should evaluate proper
operation of the compressor and condenser fan. The Refrigerator Up
key will toggle between “O” / “F” (ON & OFF)
the compressor drive circuit. The test must be “deactivated” or in the OFF position to move to another test selection.
Freezer
Refrigerator
2
O
Freezer
Refrigerator
2
F
OBSERVE COMPRESSOR & CONDENSER FAN FUNCTION
Service Test 3 – Evaporator/Freezer Fan Test
When selected and activated this test will operate the freezer fan. The Refrigerator Up
key will toggle between “O” /
“F” (ON & OFF) the fan drive circuit. You will have to inspect the fan for proper function. The test must be “deactivated” or
in the OFF position to move to another test selection.
Refrigerator
Freezer
O
3
Freezer
Refrigerator
3
F
OBSERVE FAN OPERATION
April 2004
© 2004 Maytag Services
8
16023095
April 2004
© 2004 Maytag Services
5
16023095
Service Specifications
Service Specifications
!
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Service Test 6 – Open Damper Test
Service Test 4 – Fresh Food Thermistor Test
When selected and activated this test will display Pass, Open, Short result for a test on the Fresh Food Thermistor
circuit as show below. The test is activated and de-activated via the Refrigerator Up
key, and must be
de-activated to move to another test selection.
Freezer
When selected this test will indicate the current position “O” / “C” (OPEN / CLOSED) of the refrigerator damper. The
Refrigerator Up
key will toggle the damper open and closed. You must allow 1 minute for each attempt to change the
damper position. You should observe proper damper function.
Freezer
6
Refrigerator
4
P
! CAUTION
Adjustments of Service Test 7 or Service Test 8 will alter the performance of the unit.
OPEN RESULT
Service Test 7 – FF Performance Adjustment
Refrigerator
4
This test will allow adjustment of the control performance points. Each step will incrementally change the Refrigerator
performance warmer (towards 1) or colder towards (9) as adjusted. The default value is 5.
S
The refrigerator
/
Up/Down keys are used to adjust the Performance Offset value.
WARMER Í(1 2 3 4 (5) 6 7 8 9) Î COLDER.
SHORT RESULT
Freezer
Service Test 5 – Freezer Thermistor Test
DEFAULT
Service Test 8 – FZ Performance Adjustment
This test will allow the adjustment of the control performance points. Each step will incrementally change the Freezer
performance warmer (towards 1) or colder towards (9) as adjusted. The default value is 5.
The refrigerator
/
Up/Down keys are used to adjust the Performance Offset value.
WARMER Í(1 2 3 4 (5) 6 7 8 9) Î COLDER
Refrigerator
O
Freezer
OPEN RESULT
Freezer
Refrigerator
5
8
Refrigerator
5
6
COLDER
The last FF Performance Offset value displayed before leaving test 7 will be saved when the refrigerator door(s) is closed.
PASS RESULT
5
Refrigerator
7
P
Freezer
5
Freezer
Refrigerator
5
Refrigerator
7
When selected this test will display Pass, Open, Short result for a test on the Freezer Thermistor circuit as
show below. The test is activated and de-activated via the Refrigerator Up
key, and must be de-activated
to move to another test selection.
Freezer
C
OBSERVE DAMPER FUNCTION
O
Freezer
Refrigerator
6
Refrigerator
4
O
Freezer
PASS RESULT
Freezer
Refrigerator
S
DEFAULT
Freezer
SHORT RESULT
Refrigerator
8
4
WARMER
The last FZ Performance Offset value displayed before leaving test 8 will be saved when the refrigerator door(s) is closed.
April 2004
© 2004 Maytag Services
6
16023095
April 2004
© 2004 Maytag Services
7
16023095