Adaptec Serial Attached SCSI RAID 4805SAS User's Guide

Add to my manuals
109 Pages

advertisement

Adaptec Serial Attached SCSI RAID 4805SAS User's Guide | Manualzz

SAS, SATA, and SCSI RAID Controllers

Installation and User’s Guide

2

Copyright

©2005-2006 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035.

Trademarks

Adaptec, Adaptec Storage Manager, SCSISelect, SATASelect, and the Adaptec logo are trademarks of Adaptec, Inc., which may be registered in some jurisdictions.

Microsoft and Windows are trademarks of Microsoft Corporation in the US and other countries, used under license.

Red Hat is a trademark of Red Hat, Inc. in the US and other countries, used under license.

Novell and NetWare are trademarks of Novell, Inc. in the US and other countries, used under license.

All other trademarks are the property of their respective owners.

Changes

The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Adaptec, Inc. assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein.

Adaptec reserves the right to make changes in the product design without reservation and without notification to its users.

Disclaimer

IF THIS PRODUCT DIRECTS YOU TO COPY MATERIALS, YOU MUST HAVE PERMISSION FROM THE COPYRIGHT

OWNER OF THE MATERIALS TO AVOID VIOLATING THE LAW WHICH COULD RESULT IN DAMAGES OR OTHER

REMEDIES.

3

Adaptec Customer Support

If you have questions about installing or using your Adaptec product, check this document first—you will find answers to most of your questions. If you need further assistance, use the support options listed below. To expedite your service, have your computer in front of you.

Technical Support Identification (TSID) Number

Before contacting Technical Support, you need your unique 12-digit TSID number. The TSID number identifies your product and support status.

The TSID number is included on a white, bar-coded label, like this example:

● Affix a copy of the TSID label to the CD jacket so that you don’t lose it.

North America

● Visit our Web site at www.adaptec.com

.

Search the Adaptec Support Knowledgebase (ASK) at ask.adaptec.com

for articles, troubleshooting tips, and frequently asked questions for your product.

For information about Adaptec’s support options, call +1 408-957-2550,

24 hours per day, 7 days per week. To speak with a Technical Support Specialist,

For Hardware products call +1 408-934-7274,

Monday to Friday, 3:00 A .

M . to 5:00 P .

M ., Pacific Time.

For RAID and Fibre Channel products call +1 321-207-2000,

Monday to Friday, 3:00 A .

M . to 5:00 P .

M ., Pacific Time.

For support via e-mail, submit your question at ask.adaptec.com

.

You can order Adaptec products, including accessories and cables, by calling +1 408-957-7274. Or, you can order cables online at www.adaptec.com/buy-cables .

Europe

● Visit our Web site at www.adaptec-europe.com

.

German: Call +49 89 43 66 55 22, Monday to Friday, 9:00 to 17:00, CET. For support via e-mail, submit your question at ask-de.adaptec.com

.

French: Call +49 89 43 66 55 33, Monday to Friday, 9:00 to 17:00, CET. For support via e-mail, submit your question at ask-fr.adaptec.com

.

English: Call +49 89 43 66 55 44, Monday to Friday, 9:00 to 17:00, GMT. For support via e-mail, submit your question at ask.adaptec.com

.

You can order Adaptec cables online at www.adaptec.com/buy-cables .

Japan

● Visit our Web site at www.adaptec.co.jp

.

● Call +81 3 5308 6120, Monday–Friday, 9:00 A .

M . to 12:00 P .

M and 1:00 P .

M . to 6:00 P .

M .

4

Limited 3-Year Hardware Warranty

1. Adaptec, Inc. (“Adaptec”) warrants to the purchaser of this product that it will be free from defects in material and workmanship for a period of three (3) years from the date of purchase. If the product should become defective within the warranty period, Adaptec, at its option, will repair or replace the product, or refund the purchaser’s purchase price for the product, provided it is delivered at the purchaser’s expense to an authorized Adaptec service facility or to Adaptec.

2. Repair or replacement parts or products will be furnished on an exchange basis and will either be new or reconditioned. All replaced parts or products shall become the property of Adaptec. This warranty shall not apply if the product has been damaged by accident, misuse, abuse or as a result of unauthorized service or parts.

3. Warranty service is available to the purchaser by delivering the product during the warranty period to an authorized Adaptec service facility or to Adaptec and providing proof of purchase price and date. The purchaser shall bear all shipping, packing and insurance costs and all other costs, excluding labor and parts, necessary to effectuate repair, replacement or refund under this warranty.

4. For more information on how to obtain warranty service, write or telephone Adaptec at 691 South Milpitas Boulevard,

Milpitas, CA 95035, (800) 959-7274.

5. THIS LIMITED WARRANTY DOES NOT EXTEND TO ANY PRODUCT WHICH HAS BEEN DAMAGED AS A RESULT OF

ACCIDENT, MISUSE, ABUSE, OR AS A RESULT OF UNAUTHORIZED SERVICE OR PARTS.

6. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES WHICH NOW OR HEREAFTER MIGHT

OTHERWISE ARISE RESPECT TO THIS PRODUCT. IMPLIED WARRANTIES, INCLUDING THOSE OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT SHALL (A) HAVE NO

GREATER DURATION THAN 3 YEARS FROM THE DATE OF PURCHASE, (B) TERMINATE AUTOMATICALLY AT THE

EXPIRATION OF SUCH PERIOD AND (C) TO THE EXTENT PERMITTED BY LAW BE EXCLUDED. IN THE EVENT THIS

PRODUCT BECOMES DEFECTIVE DURING THE WARRANTY PERIOD, THE PURCHASER’S EXCLUSIVE REMEDY SHALL

BE REPAIR, REPLACEMENT OR REFUND AS PROVIDED ABOVE. INCIDENTAL OR CONSEQUENTIAL DAMAGES,

INCLUDING WITHOUT LIMITATION LOSS OF DATA, ARISING FROM BREACH OF ANY EXPRESS OR IMPLIED

WARRANTY ARE NOT THE RESPONSIBILITY OF ADAPTEC AND, TO THE EXTENT PERMITTED BY LAW, ARE HEREBY

EXCLUDED BOTH FOR PROPERTY DAMAGE, AND TO THE EXTENT NOT UNCONSCIONABLE, FOR PERSONAL INJURY

DAMAGE.

7. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL

DAMAGES FOR CONSUMER PRODUCTS, AND SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN

IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU.

8. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

5

Regulatory Compliance Statements

Federal Communications Commission Radio Frequency Interference Statement

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. However, if this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between equipment and receiver.

Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/television technician for help.

Use a shielded and properly grounded I/O cable and power cable to ensure compliance of this unit to the specified limits of the rules.

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Adaptec, Inc.

ASR-4000SAS/ASR-4800SAS/ASR-4805SAS

AAR-2420SA/AAR-2820SA

ASR-2130SLP/ASR-2230SLP

Tested to Comply

With FCC Standards

FOR HOME OR OFFICE USE

European Union Compliance Statement

This Information Technology Equipment has been tested and found to comply with EMC Directive 89/336/EEC, as amended by 92/31/EEC and 93/68/EEC, in accordance with:

● EN55022 (1998) Emissions

● EN55024 (1998) Immunity:

– EN61000-4-2 (1998) Electrostatic discharge: ±4 kV contact, ±8 kV air

– EN61000-4-3 (1998) Radiated immunity

– EN61000-4-4 (1995) Electrical fast transients/burst: ±1 kV AC, ±0.5 kV I/O

– EN61000-4-5 (1995) Surges ±1 kV differential mode, ±2 kV common mode

– EN61000-4-6 (1996) Conducted immunity: 3 V

– EN61000-4-11 (1994) Supply dips and variation: 30% and 100%

In addition, all equipment requiring U.L. listing has been found to comply with EMC Directive 73/23/EEC as amended by 93/68/EEC in accordance with EN60950 with amendments A1, A2, A3, A4, A11.

Australian/New Zealand Compliance Statement

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to the Australian/New Zealand standard AS/NZS 3548 set out by the Spectrum Management Agency.

Canadian Compliance Statement

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Japanese Compliance (Voluntary Control Council Initiative)

This equipment complies to class B Information Technology equipment based on VCCI (Voluntary Control Council for Interface). This equipment is designed for home use but it may causes radio frequency interference problem if used too near to a television or radio. Please handle it correctly per this documentation.

Contents

About This Guide

What You Need to Know Before You Begin ................................................... 12

Terminology Used in this Guide ...................................................................... 12

How to Find More Information....................................................................... 12

Kit Contents and System Requirements

Kit Contents ...................................................................................................... 14

System Requirements........................................................................................ 14

About Your RAID Controller

Standard RAID Controller Features ................................................................ 17

Array-level Features .................................................................................... 17

Advanced Data Protection Suite ................................................................ 17

Adding Enhanced Features............................................................................... 18

Using a Feature Key to Unlock Enhanced Features .................................. 18

Adding a Battery Backup Module .................................................................... 18

Upgrading the Controller Firmware ................................................................ 18

About the Adaptec 4000SAS............................................................................. 19

About the Adaptec 4800SAS............................................................................. 20

About the Adaptec 4805SAS............................................................................. 21

About the Adaptec 2420SA............................................................................... 22

About the Adaptec 2820SA............................................................................... 23

About the Adaptec 2130SLP............................................................................. 24

About the Adaptec 2230SLP............................................................................. 25

Contents ●

7

Getting Started

Choosing a RAID Level..................................................................................... 27

Selecting Disk Drives ........................................................................................ 28

Disk Drives for SAS Controllers................................................................. 28

Disk Drives for SATA Controllers ............................................................. 28

Disk Drives for SCSI Controllers ............................................................... 28

Selecting Cables ................................................................................................. 29

SAS Cables................................................................................................... 29

SATA Cables................................................................................................ 29

SCSI Cables ................................................................................................. 30

Installation Options .......................................................................................... 30

Basic Installation Steps...................................................................................... 30

Installing with an Operating System.......................................................... 30

Installing on an Existing Operating System .............................................. 30

Installing the Controller and Disk Drives

Before You Begin............................................................................................... 32

Installing the Controller ................................................................................... 32

Connecting Disk Drives to SAS RAID Controllers ......................................... 33

Connecting Directly to the Controller....................................................... 33

Connecting to a System Backplane ............................................................ 34

Connecting Disk Drives to SATA RAID Controllers ...................................... 34

Connecting Disk Drives to SCSI RAID Controllers........................................ 35

Connecting External Devices............................................................................ 35

Next Steps.................................................................................................... 35

Creating a Bootable Array

Setting the Boot Controller .............................................................................. 37

Creating an Array.............................................................................................. 37

Creating an Array with the ACU ............................................................... 37

Creating an Array with Adaptec Storage Manager ................................... 39

Making Your Array Bootable ........................................................................... 40

Installing the Driver and an Operating System

Before You Begin............................................................................................... 42

Creating a Driver Disk ...................................................................................... 42

Installing with Windows................................................................................... 43

Installing with Red Hat Linux .......................................................................... 43

Installing with SuSE Linux ............................................................................... 44

Installing with NetWare.................................................................................... 44

Installing with OpenServer ............................................................................... 45

Installing with UnixWare ................................................................................. 45

Installing with FreeBSD .................................................................................... 46

Contents ●

8

Installing the Driver on an Existing Operating System

Before You Begin............................................................................................... 48

Creating a Driver Disk ...................................................................................... 48

Installing on Windows...................................................................................... 49

Installing on Red Hat or SuSE Linux ............................................................... 49

Installing on NetWare....................................................................................... 49

Installing on OpenServer .................................................................................. 50

Installing on UnixWare .................................................................................... 50

Installing on Solaris........................................................................................... 51

Installing on FreeBSD ....................................................................................... 51

Managing Your Storage Space

About Adaptec Storage Manager ..................................................................... 53

Installing Adaptec Storage Manager .......................................................... 53

About the Adaptec RAID Controller Configuration Utility........................... 53

About the Adaptec RAID Controller Utility ................................................... 54

About the Adaptec Flash Utility ....................................................................... 54

Which Utility Should I Use? ............................................................................. 54

Solving Problems

Troubleshooting Checklist ............................................................................... 56

Silencing the Alarm........................................................................................... 56

Recovering from a Disk Drive Failure ............................................................. 56

Failed Disk Drive Protected by a Hot Spare .............................................. 57

Failed Disk Drive Not Protected by a Hot Spare ....................................... 57

Failure in Multiple Arrays Simultaneously................................................ 57

Disk Drive Failure in a RAID 0 Array........................................................ 57

Multiple Failures in the Same Array .......................................................... 58

Resetting the Controller.................................................................................... 58

Introduction to Serial Attached SCSI (SAS)

Terminology Used in This Chapter ................................................................. 60

What is SAS?...................................................................................................... 60

How Do SAS Devices Communicate?.............................................................. 61

What’s a Phy? .................................................................................................... 61

What’s a SAS Port? ............................................................................................ 62

What’s a SAS Address?...................................................................................... 62

What’s a SAS Connector? ................................................................................. 62

What do SAS Cables Look Like?....................................................................... 63

How are Disk Drives Identified in SAS? .......................................................... 63

What are the SAS Connection Options?.......................................................... 63

Direct-attach Connections ......................................................................... 63

Backplane Connections .............................................................................. 64

SAS Expander Connections........................................................................ 64

How is SAS Different from Parallel SCSI? ....................................................... 65

Contents ●

9

Understanding RAID

Understanding Drive Segments ....................................................................... 67

RAID 0 (Non-RAID Arrays) ............................................................................ 67

RAID 1 Arrays ................................................................................................... 68

RAID 1 Enhanced Arrays.................................................................................. 68

RAID 10 Arrays ................................................................................................. 69

RAID 5 Arrays ................................................................................................... 70

RAID 5EE Arrays............................................................................................... 71

RAID 50 Arrays ................................................................................................. 72

RAID 6 Arrays ................................................................................................... 73

RAID 60 Arrays ................................................................................................. 73

Selecting the Best RAID Level .......................................................................... 74

Using the Adaptec RAID Controller Utility

Introduction to the Adaptec RAID Controller Utility .................................... 76

Running the Adaptec RAID Controller Utility ............................................... 76

Navigating the Adaptec RAID Controller Utility...................................... 76

Using the ACU to Create and Manage Arrays................................................. 76

Creating a New Array ................................................................................. 76

Managing Existing Arrays .......................................................................... 77

Initializing Disk Drives ............................................................................... 77

Rescanning Disk Drives.............................................................................. 77

Secure Erasing Disk Drives......................................................................... 78

Using the -Select Utility to Modify Controller Settings .................................. 78

Opening a -Select Utility............................................................................. 78

Applying Changes and Exiting................................................................... 78

Modifying Your Controller’s Configuration............................................. 79

General Controller Settings........................................................................ 79

SAS-specific Controller Settings ................................................................ 80

SATA-specific Controller Settings ............................................................. 80

SCSI-specific Controller Settings ............................................................... 81

Formatting and Verifying Disk Drives............................................................. 82

Viewing the Event Log ...................................................................................... 82

Using the ACU for DOS

Getting Started .................................................................................................. 84

Working in the ACU Using Menus.................................................................. 84

Running the ACU Using Scripts ...................................................................... 85

About Playback Mode ................................................................................ 85

About Record Mode ................................................................................... 86

Creating the Script File Manually .............................................................. 86

Array Definition Block Keywords.............................................................. 87

Channel Definition Block Keywords—SCSI only..................................... 90

ACU Error Codes........................................................................................ 91

Sample Scripts ............................................................................................. 92

Contents ●

10

Using the Adaptec Flash Utility

System Requirements........................................................................................ 95

Before You Begin............................................................................................... 95

Obtaining the Firmware ............................................................................. 95

Creating the Firmware Floppy Disks ......................................................... 96

Running the Menu-based AFU ........................................................................ 96

Running the AFU from the Command Line ................................................... 97

AFU Commands ......................................................................................... 97

Updating the Flash Using the AFU Command Line..................................... 100

Safety Information

Electrostatic Discharge (ESD) ........................................................................ 101

Technical Specifications

Environmental Specifications ........................................................................ 103

DC Power Requirements ................................................................................ 103

Current Requirements ................................................................................... 103

Index

About This Guide

1

In this chapter...

What You Need to Know Before You Begin .......................................................................... 12

Terminology Used in this Guide............................................................................................ 12

How to Find More Information ............................................................................................ 12

This Installation and User’s Guide explains how to install your Adaptec

®

RAID controller. It also describes the utilities included in your controller kit, and provides a basic overview of

Serial Attached SCSI (SAS) and Redundant Array of Independent Disk (RAID) technology.

These RAID controller models are described in this Guide:

● Adaptec 4000SAS

Adaptec 4800SAS

Adaptec 4805SAS

Adaptec 2420SA

Adaptec 2820SA

Adaptec 2130SLP

Adaptec 2230SLP

Chapter 1: About This Guide ●

12

What You Need to Know Before You Begin

You should be familiar with computer hardware, data storage, RAID technology, and the input/output (I/O) technology—Small Computer System Interface (SCSI), SAS, or Serial ATA

(SATA)—used by your controller. (For an introduction to SAS, see page 59

.)

You should also be familiar with Direct Attached Storage (DAS) and Storage Area Network

(SAN) concepts and technology.

Note: Because this Guide covers multiple Adaptec RAID products, some of the features and

functions described may not be available for your controller. For more information, see About

Your RAID Controller on page 16

.

Terminology Used in this Guide

Because you can use your Adaptec RAID controller to manage data storage in a variety of configurations from DAS to SAN, the generic term “storage space” is used to refer to controller(s) and disk drives being managed with Adaptec Storage Manager TM or the other utilities described in this Guide.

Many of the terms and concepts referred to in this Guide are known to computer users by multiple names. This Guide uses these terms:

Controller (also known as adapter, board, or card)

Disk drive (also known as hard disk, hard drive, or hard disk drive)

Array (also known as a container or logical drive)

Note: The Adaptec Storage Manager User’s Guide refers to arrays as logical drives. Why?

Your RAID controller creates arrays, which your operating system (and Adaptec Storage

Manager) recognizes as logical drives.

How to Find More Information

You can find more information about your Adaptec RAID controller and the software and utilities included with it by referring to these documents:

Readme.txt—Includes updated product information and known issues; located on the

RAID Installation CD.

Adaptec Storage Manager User’s Guide—Describes how to install and use the Adaptec

Storage Manager software (see

page 53 ); located on the Adaptec Storage Manager

Installation CD.

Adaptec Storage Manager online Help—Describes how to use the Adaptec Storage Manager software; accessible from the main window of Adaptec Storage Manager.

Command Line Utility User’s Guide—Describes how to use the command line utility

(ARCCONF—see page 53

) to perform basic array and configuration management functions; located on the Adaptec Storage Manager Installation CD.

Kit Contents and System

Requirements

2

In this chapter...

Kit Contents............................................................................................................................ 14

System Requirements ............................................................................................................. 14

This chapter lists the contents of your Adaptec RAID controller kit and the system requirements that must be met for you to successfully install and use your controller.

Chapter 2: Kit Contents and System Requirements ●

14

Kit Contents

● Adaptec RAID controller

RAID Installation CD (bootable), including controller drivers, and this Guide

Adaptec Storage Manager

Installation CD (not bootable), including user guides for

Adaptec Storage Manager and the Adaptec RAID controller configuration command line utility (ARCCONF)

Cables (type and quantity vary—for cable information about your controller, see About

Your RAID Controller on page 16 )

(Selected models only) Low-profile bracket

Adaptec RAID Controller Quick Start Guide

System Requirements

● PC-compatible computer with Intel Pentium, or equivalent, processor

Motherboard with these features:

Compliant with PCI Local Bus Specification, Revision 2.2 or later

Support for multifunction devices where one of the devices is a PCI bridge

Large memory-mapped address ranges

Refer to the Readme file on the RAID installation CD for additional motherboard compatibility information.

One of these operating systems:

Microsoft

®

Windows

®

2000, Windows Server 2003, Windows XP

Red Hat

®

Linux

SuSE Linux

Note: For the latest on Adaptec’s support of Linux, or to download driver sources, visit the Support area of the Adaptec Web site at www.adaptec.com.

Novell

®

NetWare

®

SCO

®

OpenServer

®

6.0

UnixWare

®

7.1.4

Sun

®

Solaris TM 10 (supports secondary controllers only, not boot controller; storage management must be done through the Adaptec Configuration Utility—see

page 76 )

FreeBSD 5.4, 6.0 (driver support only; storage management must be done through the

Adaptec Configuration Utility—see

page 76 )

Note: For up-to-date operating system version support, refer to the Adaptec Web Site at www.adaptec.com.

● 128 MB (or more) of RAM

Chapter 2: Kit Contents and System Requirements ●

15

● Available compatible PCI/PCI-X/PCI-E slot (depending on your controller model—see

the descriptions starting on page 16

)

20 MB of free disk drive space

16-bit SVGA color monitor with a resolution of at least 800 x 600

CD drive

About Your RAID Controller

3

In this chapter...

Standard RAID Controller Features ...................................................................................... 17

Adding Enhanced Features .................................................................................................... 18

Adding a Battery Backup Module ......................................................................................... 18

Upgrading the Controller Firmware ..................................................................................... 18

About the Adaptec 4000SAS .................................................................................................. 19

About the Adaptec 4800SAS .................................................................................................. 20

About the Adaptec 4805SAS .................................................................................................. 21

About the Adaptec 2420SA .................................................................................................... 22

About the Adaptec 2820SA .................................................................................................... 23

About the Adaptec 2130SLP .................................................................................................. 24

About the Adaptec 2230SLP .................................................................................................. 25

This chapter provides an overview of standard Adaptec RAID controller features, and describes the unique features of your controller. It also explains how to upgrade your controller with enhanced features.

Chapter 3: About Your RAID Controller ●

17

Standard RAID Controller Features

● Flash ROM for updates to controller firmware, BIOS, and the Adaptec RAID

Configuration utility

Disk drive hot-swapping

Event logging and broadcasting including email and SNMP messages

Multiple options for creating and managing RAID arrays—A full software application

(Adaptec Storage Manager), a BIOS-based utility, a command line utility, and a DOS utility. See

Managing Your Storage Space on page 52 for more information.

(SAS and SATA RAID controllers only) Native command queuing (NCQ), which lets disk drives arrange commands into the most efficient order for optimum performance

(SAS and SCSI RAID controllers only) Support for disk drive enclosures with SAF-TE enclosure management hardware

● (SAS RAID controllers only) Support for disk drive enclosures with SES2 enclosure management hardware

Some RAID controllers support a battery backup module (see page 18

).

Array-level Features

Note: For more information, refer to the Adaptec Storage Manager User’s Guide or online Help.

Support for RAID 0, RAID 1, RAID 5, RAID 10, RAID 50

1

, simple volumes, and spanned volumes

Support for hot spares (global and dedicated)

Support for automatic failover, so arrays are automatically rebuilt when a failed disk drive is replaced (applies to redundant arrays in SES2- or SAF-TE-enabled disk drive enclosures only)

Optimized disk utilization, which ensures that the full capacity of all disk drives can be used, even if the disk drives vary in size

Online capacity expansion, so you can increase the capacity of an array without recreating it

Support for array migration from one RAID level to another ●

Advanced Data Protection Suite

Copyback Hot Spare—You can use this feature to move data from a hot spare back to its original location after a failed disk drive is replaced.

Striped Mirror (RAID 1E)—A RAID 1 Enhanced array is similar to a RAID 1 array except that data is both mirrored and striped, and more disk drives can be included.

Hot Space (RAID 5EE)—A RAID 5EE array is similar to a RAID 5 array except that it includes a distributed spare and must be built from a minimum of four disk drives.

Dual Drive Failure Protection (RAID 6)—A RAID 6 array is similar to a RAID 5 array except that it includes two independent sets of parity data instead of one.

Dual Drive Failure Protection (RAID 60

1

)—A RAID 60 array is similar to a RAID 50 array except that it includes four independent sets of parity data instead of two.

1

The Adaptec 2420SA RAID controller does not support RAID 50 or RAID 60.

Chapter 3: About Your RAID Controller ●

18

Adding Enhanced Features

As your storage needs change, you can enhance data protection and improve performance by upgrading your Adaptec controller with extra features.

Currently, Adaptec offers the snapshot function as an upgrade feature which can be activated with a feature key (sold separately). A snapshot is a frozen image of a logical drive at a particular point in time. You can use this feature to back up your data to tape, clone a disk drive, or copy the data to multiple servers.

Note: Snapshots are supported by Windows and Linux operating systems only.

To purchase a feature key, contact your Adaptec Reseller or refer to the Adaptec Web site at www.adaptec.com

. To unlock the enhanced features with a feature key, see

page 18 .

Using a Feature Key to Unlock Enhanced Features

When you receive a feature key, use Adaptec Storage Manager to unlock the new features. For step-by-step instructions, follow the instructions in the online Help or the Adaptec Storage

Manager User’s Guide on the Adaptec Storage Manager Installation CD.

Adding a Battery Backup Module

This table shows the battery model supported by your Adaptec RAID controller.

RAID Controller

Adaptec 4800SAS / Adaptec 4805SAS

Adaptec 2420SA / Adaptec 2820SA

Adaptec 2130SLP / Adaptec 2230SLP

Battery Model

Adaptec Battery Module 600

Adaptec Battery Module 500

Adaptec Battery Module 400

To purchase a backup battery module, refer to the Adaptec Web site at www.adaptec.com

.

Upgrading the Controller Firmware

To upgrade the firmware on your Adaptec RAID controller, follow the instructions in Using the

Adaptec Flash Utility on page 94 .

Chapter 3: About Your RAID Controller ●

19

About the Adaptec 4000SAS

The Adaptec 4000SAS is a low-profile SAS Zero Channel RAID controller with these features:

Mode 0 Flash connector LED connector

I2C connector

Mounting bracket

PCI-X connector

Bus compatibility

Maximum bus width

Maximum bus speed

Standard cache

Maximum number of disk drives

Audible alarm

PCI-X

64-bit

133 MHz

128 MB

8

No

Chapter 3: About Your RAID Controller ●

20

About the Adaptec 4800SAS

The Adaptec 4800SAS is a SAS RAID controller with these features:

Alarm connector

Mounting bracket

Two 4-wide internal

SAS connectors

Mode 0 Flash connector

Activity LED connector

(top 2 left/right pins)

One external

SAS connector

Battery connector

PCI-X connector

Bus compatibility

Maximum bus width

PCI-X

64-bit

Maximum bus speed 133 MHz

I/O processor clock frequency 500 MHz

Standard cache

128 MB DDR2

1

Maximum number of disk drives 8 (or up to 128 with expanders)

SAS cables included 2 (internal)

Battery backup module

Audible alarm

1

256 MB also available

Adaptec Battery Module 600 (sold separately—see

page 18 )

Yes

Note: Although this controller has an onboard speaker, you can connect it to an internal speaker with these specifications: 3.0 V, 90.0 mA. The internal speaker is not required, as the onboard speaker volume is appropriate for most environments.

Chapter 3: About Your RAID Controller ●

21

About the Adaptec 4805SAS

The Adaptec 4805SAS is a SAS RAID controller with these features:

Mounting bracket

Alarm connector

Two 4-wide internal

SAS connectors

Mode 0 Flash connector

Activity LED connector

(top 2 left/right pins)

One external

SAS connector

PCI-E connector

Battery connector

Bus compatibility PCI-E x8

I/O processor clock frequency 500 MHz

Standard cache

128 MB DDR2

1

Maximum number of disk drives 8 (or up to 128 with expanders)

SAS cables included 2 (internal)

Battery backup module

Audible alarm

1

256 MB also available

Adaptec Battery Module 600 (sold separately—see page 18 )

Yes

Note: Although this controller has an onboard speaker, you can connect it to an internal speaker with these specifications: 3.0 V, 90.0 mA. The internal speaker is not required, as the onboard speaker volume is appropriate for most environments.

About the Adaptec 2420SA

The Adaptec 2420SA is a SATA RAID controller with these features:

0

SATA ports

3

1

2

Mode 0 Flash connector

Activity LED connector

I2C connector

Chapter 3: About Your RAID Controller ●

22

Mounting bracket

Battery connector

PCI-X connector

Bus compatibility

Bus width

Bus speed

Standard cache

PCI-X, 3.3 V

64-bit

133 MHz

128 MB

1

Maximum number of disk drives 4

SATA cables included 4

Battery backup module

Audible alarm

Adaptec Battery Module 500 (sold separately—see page 18 )

Yes

1

256 MB also available

Note: A low-profile bracket is included with this controller. However, this controller may not fit in all low-profile systems.

Chapter 3: About Your RAID Controller ●

23

About the Adaptec 2820SA

The Adaptec 2820SA is a SATA RAID controller with these features:

0

1

2

3

4

SATA ports

7

5

6

Mode 0 Flash connector

Activity LED connectors

I2C connector

Mounting bracket

Battery connector

PCI-X connector

Bus compatibility

Bus width

Bus speed

Standard cache

133 MHz

128 MB

1

Maximum number of disk drives 8

SATA cables included 8

Battery backup module

Audible alarm

Adaptec Battery Module 500 (sold separately—see page 18 )

Yes

1

256 MB also available

PCI-X, 3.3 V

64-bit

Note: A low-profile bracket is included with this controller. However, this controller may not fit in all low-profile systems.

Chapter 3: About Your RAID Controller ●

24

About the Adaptec 2130SLP

The Adaptec 2130SLP is a low-profile controller with these features:

Mode 0 Flash connector

Activity LED connector

Internal HD SCSI connector

Battery connector

Mounting bracket

External VHDCI

SCSI connector

PCI/PCI-X connector

Bus compatibility

Maximum bus width

Maximum bus speed

Standard cache

Number of channels

PCI / PCI-X, 3.3 V

64-bit

133 MHz

128 MB or 256 MB (depending on your controller configuration)

1

Maximum number of disk drives 15

SCSI cables included 1 (internal)

Battery backup module

Audible alarm

Adaptec Battery Module 400 (sold separately—see page 18 )

Yes

Chapter 3: About Your RAID Controller ●

25

About the Adaptec 2230SLP

The Adaptec 2230SLP is a low-profile controller with these features:

Mode 0 Flash connector

Activity LED connector

Battery connector

2 internal HD SCSI connectors

2 external VHDCI SCSI connectors

Mounting bracket

PCI/PCI-X connector

Bus compatibility

Maximum bus width

Maximum bus speed

Standard cache

Number of channels

Maximum number of disk drives

SCSI cables included

Battery backup module

Audible alarm

PCI / PCI-X, 3.3 V

64-bit

133 MHz

128 MB or 256 MB (depending on your controller configuration)

2

30 (15 per channel)

1 (internal)

Adaptec Battery Module 400 (sold separately—see

page 18

)

Yes

Getting Started

4

In this chapter...

Choosing a RAID Level.......................................................................................................... 27

Selecting Disk Drives.............................................................................................................. 28

Selecting Cables ...................................................................................................................... 29

Installation Options ............................................................................................................... 30

Basic Installation Steps........................................................................................................... 30

This chapter provides the basic information you need to set up your disk drives and arrays the way you want them. It also describes the options you have for installing your Adaptec controller and disk drives, and creating arrays for data storage.

Note: Before you begin, familiarize yourself with your Adaptec controller’s physical features

and the RAID levels that it supports (see About Your RAID Controller on page 16

).

Chapter 4: Getting Started ●

27

Choosing a RAID Level

This section provides a brief overview of the RAID levels supported by your Adaptec RAID controller, including the minimum and maximum number of disk drives required by each.

RAID 0 (Non-redundant Array)—Stripes data across multiple disk drives. Improved performance but no redundancy (see

page 67 ).

RAID 1 Array—Created from two disk drives where one disk drive is a mirror of the other

(the same data is stored on each disk drive). Redundancy, but reduced capacity (see

page 68

).

RAID 1E Array—Similar to a RAID 1 array except that data is mirrored and striped, and more

disk drives can be included (see page 68

).

RAID 5 Array—Stripes data for improved performance and uses parity data to provide redundancy (see

page 70 ).

RAID 5EE Array—Similar to a RAID 5 array, but includes a distributed spare and must

include a minimum of four disk drives (see page 71

).

RAID 10 Array—Built from two or more equal-sized RAID 1 arrays, stripes and mirrors data across multiple disk drives. Redundancy and improved performance (see

page 69 ).

RAID 50

1

Array—Built from multiple disk drives configured as two or more RAID 5

arrays, stripes stored data and parity data across all disk drives (see page 72

).

RAID 6 Array—Similar to a RAID 5 array except that it includes two independent sets of parity data instead of one (see

page 73 ).

● RAID 60

*

Array—Similar to a RAID 50 array except that it includes four independent sets of parity data instead of two (see

page 73 ).

Use the table on page 74

to see how many disk drives you must connect to your RAID controller to support the RAID level you want.

1

Because it supports four disk drives only, the Adaptec 2420SA RAID controller can’t support RAID 50 or RAID 60.

Chapter 4: Getting Started ●

28

Selecting Disk Drives

When selecting disk drives for your RAID array, ensure that all the disk drives have the same performance level. You can use different-sized disk drives in the array, but the array will be limited to the capacity of the smallest and slowest disk drive.

For more information, refer to the Adaptec Storage Manager User’s Guide or online Help.

Disk Drives for SAS Controllers

Your SAS controller supports both SAS and SATA disk drives. For cable information, see page 29

.

Disk Drives for SATA Controllers

Your SATA controller supports SATA disk drives only. You need one SATA cable for each disk drive you are connecting to your SATA controller.

Disk Drives for SCSI Controllers

Your SCSI controller supports Ultra320 SCSI disk drives. It also supports Ultra2 or higher SCSI disk drives and peripherals, but at performance levels less than Ultra320. Adaptec does not recommend using SCSI disk drives or peripherals older than Ultra2.

Note: High-voltage Differential (HVD) disk drives are not supported and will damage your controller.

If you are mixing single-ended (SE) disk drives with Low-voltage Differential (LVD) disk drives:

● Ensure proper termination by using a cable (like the one included in the kit) with a built-in multimode terminator and proper adapters.

Disable termination on all the SE disk drives.

Put LVD and SE disk drives on separate channels for the best performance.

Note: If you mix SE and Ultra320 disk drives on the same channel, the performance of the

Ultra320 disk drives is reduced to SE levels.

Chapter 4: Getting Started ●

29

Selecting Cables

This section describes the cable options and requirements for your Adaptec controller:

For SAS cables, see this page.

SATA cables, see this page.

SCSI cables, see

page 30 .

SAS Cables

You need one SAS cable for each disk drive you are connecting to your Adaptec SAS RAID controller.

Depending on your requirements, you can use any of these cables:

Internal cable—Connects to a backplane.

Internal fan-out cable—Connects to four internal SATA disk drives.

(SAS-to-SAS fan-out cables—not shown—are also available.)

External cable—Connects to an external SAS enclosure.

Cable connectors are keyed so that you can’t insert them incorrectly.

Adaptec recommends using only Adaptec SAS cables. For more information or to purchase cables, visit the Adaptec Web site at www.adaptec.com

.

SATA Cables

You need one SATA cable for each disk drive you are connecting to your Adaptec SATA RAID controller. SATA cables are included in the kit.

All SATA cables have the same connectors, as shown in the following figure, and the connectors are keyed so that you can’t insert them incorrectly.

Adaptec recommends using only Adaptec SATA cables. For more information or to purchase cables, visit the Adaptec Web site at www.adaptec.com

.

Chapter 4: Getting Started ●

30

SCSI Cables

Depending on your requirements, you may need one or two internal cables. You may also need one external SCSI cable. Ensure that you have cables with the proper connectors for your RAID controller. One internal SCSI cable is included in the kit.

Internal SCSI cable—Connects to up to seven internal SCSI disk drives and devices.

External SCSI cable—Connects to an external SCSI disk drive or device.

Adaptec recommends using only high-quality Ultra320-rated cables with multimode terminators for all disk drives that share a channel with Ultra320 disk drives. Avoid poor quality cables, as they may degrade reliability. Do not use cables not rated for Ultra320 operation.

Adaptec recommends using only Adaptec SCSI cables. For more information or to purchase cables, visit the Adaptec Web site at www.adaptec.com

.

Installation Options

When you install your Adaptec controller, you can choose to create a bootable array and then install your operating system and the controller driver on that array.

Alternatively, you can complete a standard installation, where the controller driver is installed on an existing operating system.

Basic Installation Steps

This section describes the installation process. Follow the steps for the installation option you’ve chosen.

Installing with an Operating System

1 Install and connect your controller and internal disk drives (see

page 31 ).

2

3

4

5

If your controller has an external connector, you can connect external disk drives as well

(or instead).

Set the boot controller (see page 37

).

Create a bootable array (see

page 37 ).

Install your operating system and the controller driver (see page 41

.)

Install Adaptec Storage Manager and begin to manage your data storage (see page 52

).

Installing on an Existing Operating System

1 Install and connect your controller and internal disk drives (see

page 31 ).

2

If your controller has an external connector, you can connect external disk drives as well

(or instead).

Install the controller driver (see

page 47 ).

3

Install Adaptec Storage Manager and begin to manage your data storage (see page 52

).

Installing the Controller and Disk

Drives

5

In this chapter...

Before You Begin .................................................................................................................... 32

Installing the Controller......................................................................................................... 32

Connecting Disk Drives to SAS RAID Controllers............................................................... 33

Connecting Disk Drives to SATA RAID Controllers ............................................................ 34

Connecting Disk Drives to SCSI RAID Controllers ............................................................. 35

Connecting External Devices................................................................................................. 35

This chapter explains how to install your Adaptec RAID controller, and how to install and connect internal and external disk drives.

Chapter 5: Installing the Controller and Disk Drives ●

32

Before You Begin

Read Safety Information on page 101 .

Familiarize yourself with your Adaptec RAID controller’s physical features and the RAID levels that it supports (see

page 16 ).

Ensure you have the right quantity of disk drives for the RAID level you want to use for

your arrays (see page 28

).

Ensure that you have the proper cables for your controller and disk drives (see

page 29 ).

If you are installing a low-profile RAID controller into a low-profile computer cabinet, replace the original full-height bracket with the low-profile bracket included in the kit.

Caution: Handle the controller by its bracket or edges only.

!

Installing the Controller

This section describes how to install your Adaptec RAID controller into your computer cabinet.

1

2

Turn off your computer and disconnect the power cord. Open the cabinet, following the manufacturer’s instructions.

Select an available PCI expansion slot that’s compatible with your RAID controller and remove the PCI slot cover, as shown at right. (PCI bus compatibility is marked on the controller

figures in About Your RAID Controller on page 16

.)

For the best performance, use the fastest available PCI slot that’s compatible with your RAID controller.

!

Caution: Touch a grounded metal object before handling the RAID controller.

3

4

5

As shown at right, insert the RAID controller into the PCI expansion slot and press down gently but firmly until it clicks into place. When installed properly, the RAID controller should appear level with the PCI expansion slot.

Secure the bracket in the PCI slot, using the retention device

(for instance, a screw or lever) supplied with your computer.

Connect your computer’s disk activity LED cable to the LED

connector on the controller (marked on the figures in About

Your RAID Controller on page 16

).

Ensure that the positive lead of the LED cable (usually a red wire or a wire marked with a red stripe) is attached to pin 1.

Note: Adaptec 4000SAS only—Controller installation is complete. If you are installing the controller driver and an operating system on a bootable array, continue with

Creating a

Bootable Array on page 36 .

If you are completing a standard installation onto an existing operating system, continue with

Installing the Driver on an Existing Operating System on page 47 .

6 Optional—Connect your RAID controller’s I2C connector (not available on all models) to an I2C connector on an internal backplane or enclosure, using an I2C cable.

Chapter 5: Installing the Controller and Disk Drives ●

33

7 Prepare and install your internal disk drives, following the instructions for your type of controller:

For SAS RAID controllers, see

page 33 .

For SATA RAID controllers, see

page 34 .

For SCSI RAID controllers, see

page 35 .

If you are not installing internal disk drives, close your computer cabinet, reattach the

power cord, then continue with Connecting External Devices on page 35 .

Connecting Disk Drives to SAS RAID Controllers

You can connect SAS disk drives, SATA disk drives, or a combination of both to your SAS RAID controller. There are no jumpers or switches to set before installation.

If you plan to build a bootable array using internal disk drives, ensure you install at least the

minimum number disk drives required to support the RAID level you want. See page 27

for more information.

Note: Although you can connect both SAS and SATA disk drives to your SAS controller, Adaptec recommends that you not combine SAS and SATA disk drives within the same array or logical

drive. See page 60

for more information.

You have two connection options:

● To connect directly to the controller, see the following section.

To connect to a backplane, see page 34

.

Connecting Directly to the Controller

In a direct-attach connection, SAS or SATA disk drives are connected directly to a SAS card with SAS cables.The number of direct-attached disk drives is limited to four per internal SAS

connector. (For more information about direct-attach connections, see page 63 .)

1

2

Install your internal SAS or SATA disk drives, following the instructions in your system’s documentation.

Use internal SAS cables to attach the disk drives to the controller. (SATA disk drives are shown in the following figure.)

SATA disk drives attached to controller with fan-out cable

3 When all internal disk drives have been installed and attached to the controller, close your

computer cabinet, reattach the power cord, then continue with Connecting External

Devices on page 35 .

Chapter 5: Installing the Controller and Disk Drives ●

34

Connecting to a System Backplane

In a backplane connection, disk drives and SAS cards are attached to and communicate with each other through a system backplane.

The number of disk drives is limited to the number of slots available on the backplane. Some backplanes have embedded SAS expanders and can support up to 128 end devices. (For more

information about backplane and expander connections, see page 63

.)

1

2

Connect one or more internal SAS or SATA disk drives to the backplane. (Refer to your system’s documentation for more information.)

Use an internal SAS cable to connect the controller to the backplane.

Disk drives on backplane

Controller connected to backplane with fan-out cable

3 When all internal disk drives have been installed and connected, close your computer

cabinet, reattach the power cord, then continue with Connecting External Devices on page 35

.

Connecting Disk Drives to SATA RAID Controllers

1 Install your SATA disk drives, following the instructions in your system’s documentation.

There are no jumpers or switches to set on the SATA controller or disk drives.

2

3

Use one SATA cable to connect each disk drive to a SATA port on the controller.

When all internal disk drives have been installed and connected, close your computer cabinet, and reattach the power cord.

Continue by either setting the boot controller (see

page 36 ) or by installing the controller

driver on an existing operating system (see

page 47 ), depending on the type of installation

you are completing.

Chapter 5: Installing the Controller and Disk Drives ●

35

Connecting Disk Drives to SCSI RAID Controllers

1 For each controller channel, set the SCSI ID of each disk drive to a unique number between

0 and 15.

The controller is set to ID 7 by default. Although not recommended, you can change the controller ID by using the Adaptec RAID Controller utility (see

page 75 ).

Note: Do not change the controller ID unless absolutely necessary.

2

3

4

Install a terminator (or enable termination) on the disk drive at the end of each cable, or the end of the cable itself.

Remove any terminators (or disable termination) on disk drives between the ends of each cable.

Install your SCSI disk drives, following the instructions in your system’s documentation.

If space inside your computer cabinet is limited, connect your disk drives to the SCSI cable

before installing them. (For installation instructions, refer to your computer’s documentation.)

!

Caution: To avoid causing unstable operation, do not attach a cable to the controller unless the other end of the cable is attached to a least one disk drive.

Alternatively, install your disk drives, then connect them to the controller.

When all internal disk drives have been installed and connected, close your computer

cabinet, reattach the power cord, then continue with Connecting External Devices on page 35

.

Connecting External Devices

Note: If you are not connecting any external devices, see the following section,

Next Steps .

1

2

(SCSI controllers only) Ensure that SCSI IDs and termination are set before completing the

connections to external disk drives or devices. See page 35

.

Use high-quality cables to connect your controller to your external device(s), such as disk drives or disk drive enclosures.

Adaptec recommends using only Adaptec cables. For more information or to purchase cables, visit the Adaptec Web site at www.adaptec.com

..

Next Steps

If you are installing the controller driver and an operating system onto a bootable array, continue with

Creating a Bootable Array on page 36

.

If you are completing a standard installation onto an existing operating system, continue with

Installing the Driver on an Existing Operating System on page 47

.

Creating a Bootable Array

6

In this chapter...

Setting the Boot Controller.................................................................................................... 37

Creating an Array ................................................................................................................... 37

Making Your Array Bootable ................................................................................................. 40

This chapter explains how to set your Adaptec controller to be the boot controller, and how to create a bootable array.

Note: If you are completing a standard installation onto an existing operating system, you

don’t have to complete this task. Skip to Installing the Driver on an Existing Operating System on page 47 .

Chapter 6: Creating a Bootable Array ●

37

Setting the Boot Controller

Note: If your system won’t contain more than one bootable controller, skip to the next section,

Creating an Array

.

Your Adaptec RAID controller supports bootable disk drives and bootable arrays. To enable your system to boot from either a disk drive or an array connected to your controller:

1

2

Enter the system setup.

Navigate to the drive boot sequence.

3 Move the boot controller to the top of the list.

For more information, refer to your computer’s documentation.

Creating an Array

This section explains how to create an array.

A RAID 5 array is created in the examples shown in this section because RAID 5 provides the most security and best performance with a minimum of three disk drives. However, you can choose to create an array with a different RAID level; you can also change array level later, after the operating system is installed.

You can create an array using either of these tools:

Array Configuration Utility—BIOS-based menus and keyboard navigation (see the following section).

Adaptec Storage Manager—Graphical software application (running from a bootable CD) that you can navigate with your mouse (see

page 53

).

You can use either tool, but the Adaptec RAID Controller utility is the quicker and easier tool for this task.

Note: Adaptec recommends that you not combine SAS and SATA disk drives within the same array. Adaptec Storage Manager generates a warning if you try to create a logical drive using a

combination of SAS and SATA disk drives. See page 60 for more information.

Creating an Array with the ACU

The ACU is menu-based and instructions for completing tasks appear on-screen. Menus can be navigated using the arrows, Enter, Esc, and other keys on your keyboard.

To create a RAID 5 array:

1 Power on your computer. When prompted, press Ctrl+A to enter the Adaptec RAID

Controller utility.

2

3

4

If you have more than one controller of the same model or family in your computer, select your controller, then press Enter.

Select Array Configuration Utility, then press Enter.

Select Initialize Drives, then press Enter.

Chapter 6: Creating a Bootable Array ●

38

7

8

5

6

9

Select at least three disk drives for the array, press Insert for each selected disk drive, then press Enter.

!

Caution: During initialization, all data is deleted from the disk. Before continuing, back up any data you want to keep.

Press Y, then press Enter.

The selected disk drives are initialized, then the Adaptec Configuration Utility screen appears.

Select Create Array, then press Enter.

Select the disk drives that were just initialized, press Insert for each selected disk drive, then press Enter.

When the Array Properties screen opens, follow the instructions in the following table:

Property Line

Array Type

Array Label

Array Size

Stripe Size

Entry or Selection

Select RAID 5, then press Enter.

Type a name, then press Enter.

Press Enter, then press Enter again to use the default granularity of GB.

Press Enter to use the default (256KB).

Read Caching

Write Caching

Press Enter to use the default (Yes).

Press Enter to use the default (Enable always).

Create RAID via Press Enter to use the default (Build/Verify).

[Done] Press Enter.

10 When a cache warning message displays, type Y.

11 Once the array is created, a message displays telling you that the array can now be used.

Press any key to return to the ACU Menu.

You can start using the array immediately. However, performance is reduced until the build process is complete.

12 Press Esc until the Exit Utility window appears.

13 Select Yes, then press Enter.

The computer restarts.

14 Continue with

Making Your Array Bootable on page 40

.

Chapter 6: Creating a Bootable Array ●

39

Creating an Array with Adaptec Storage Manager

This section describes how to use the Adaptec Storage Manager configuration wizard to build a

RAID 5 array.

Note: You will need the RAID Installation CD to complete this task.

To create a RAID 5 array:

1 Insert the RAID Installation CD into your CD drive, then restart your computer.

2

3

When prompted, select the language you want, then press Enter.

Review the license information, then press Enter.

4

5

The main menu opens.

Click Launch Configuration Utility.

Adaptec Storage Manager opens.

Click Create.

The Configuration wizard opens.

6 Select Express configuration..., then click Next.

Chapter 6: Creating a Bootable Array ●

40

7 Review the information that is displayed.

Note: Adaptec Storage Manager uses the term logical drives when referring to arrays (see

page 12

).

In this example, Adaptec Storage Manager has used four equal-sized disk drives to automatically create one logical drive with RAID 5 and a hot spare.

8

To specify a size for the logical drives, or to make other changes to the configuration, click

Modify logical devices.

Click Apply, then click Yes when prompted to confirm applying your new configuration.

Adaptec Storage Manager builds the logical drive(s).

9

The configuration is saved on the Adaptec controller (as an “array”, see page 12 ) and on the

physical disk drives.

Partition and format your logical drive.

The logical drive you created appears as a physical disk drive on your operating system.

You must partition and format these logical drives before you can use them to store data.

10 Close all windows, then click Reboot to restart your system.

11 Remove the RAID Installation CD.

For information on installing and using Adaptec Storage Manager as a full software application, refer to the Adaptec Storage Manager User’s Guide or online Help.

12 Continue with

Making Your Array Bootable on page 40

.

Making Your Array Bootable

Use the ACU to make the array bootable (see

Creating Bootable Arrays on page 77

).

Then continue with Installing the Driver and an Operating System on page 41

.

Installing the Driver and an

Operating System

7

In this chapter...

Before You Begin .................................................................................................................... 42

Creating a Driver Disk ........................................................................................................... 42

Installing with Windows ........................................................................................................ 43

Installing with Red Hat Linux ............................................................................................... 43

Installing with SuSE Linux..................................................................................................... 44

Installing with NetWare ......................................................................................................... 44

Installing with OpenServer .................................................................................................... 45

Installing with UnixWare ....................................................................................................... 45

Installing with FreeBSD ......................................................................................................... 46

This chapter explains how to install your Adaptec RAID controller driver and an operating

system onto a bootable array (see page 36

).

Note: Solaris users only—You cannot use your Adaptec RAID controller as a boot controller. To install the driver on a computer with Solaris already installed, see

page 51

.

To install the driver on an existing operating system, see

page 47

.

Chapter 7: Installing the Driver and an Operating System ●

42

Before You Begin

Install and connect your Adaptec RAID controller and internal disk drives (see page 31

).

Create a bootable array (see

page 36 ).

Create a driver disk (see the following section).

Creating a Driver Disk

Note: You will need a floppy disk to complete this task.

To create a driver disk:

1

2

Set your system BIOS so that your computer boots from the CD drive. (For instructions, refer to your computer’s documentation.)

Turn on your computer, then insert the RAID Installation CD included in your RAID controller kit.

3

4

Follow the on-screen instructions to get to the Adaptec Start Menu.

Click Create Driver Disk, then select your operating system.

5

6

7

8

Linux only—If prompted, select your operating system and the architecture:

Intel 386 or 486 computers—Select i386.

Pentium I or II computers—Select i586.

Pentium III, IV, or AMD K-6 computers—Select i686.

AMD Athlon computers—Select Athlon.

Select your floppy disk drive letter, then select the format you want. (You need a full format only if your floppy disk has never been formatted or may have bad sectors.)

Insert the floppy disk, then click OK.

The system creates the driver disk.

Remove and label the driver disk.

Continue with the instructions for your operating system:

For Windows, see

page 43 .

For Red Hat Linux, see page 43

.

For SuSE Linux, see

page 44 .

For NetWare, see

page 44 .

For OpenServer, see page 45

.

For UnixWare, see page 45

.

For FreeBSD, see page 46

.

Chapter 7: Installing the Driver and an Operating System ●

43

Installing with Windows

Note: You will need your Windows installation CD to complete this task.

4

5

6

7

8

To install the Adaptec RAID controller driver while installing Windows:

1 Insert your Windows CD, then restart the computer.

2

3

Follow the on-screen instructions to begin the Windows installation.

When prompted to install a third-party driver, press F6.

Note: When F6 is active, a prompt appears at the bottom of the screen for only 5 seconds.

If you miss your chance to press F6, restart your computer.

Insert the driver disk, then wait until you are prompted to install a driver.

Press S to specify that the driver is on a floppy disk, then press Enter.

The computer reads the disk.

When the Adaptec driver is found, press Enter.

Follow the on-screen instructions to complete the installation.

Continue with

Managing Your Storage Space on page 52

.

Installing with Red Hat Linux

Note: You will need your Red Hat installation CD to complete this task.

To install the Adaptec RAID controller driver while installing Red Hat Linux:

1 Insert the first Red Hat installation CD.

2

3

Restart your computer.

When the Red Hat Welcome screen appears, type linux dd at the Boot: prompt.

4

5

6

7

8

When prompted, insert the driver disk, then select OK.

Follow the prompts to set up the environment you want.

If you are installing other third-party devices, install them now. Otherwise, select Done.

Complete the Linux installation, following the instructions included with your operating system.

Continue with

Managing Your Storage Space on page 52

.

Chapter 7: Installing the Driver and an Operating System ●

44

Installing with SuSE Linux

To install the Adaptec RAID controller driver while installing SuSE Linux:

1

2

3

4

5

6

7

8

Insert the first SuSE installation CD.

Restart your computer.

When the SuSE installation selection screen appears, choose the type of installation you want, then press the F6 key to indicate the use of a driver disk. (If F6 is not shown on the screen, you may have an older version of SuSE; press the Alt key instead.)

When prompted, insert the driver disk, then press any key to continue.

Follow the prompts to set up the environment you want.

If you are installing other third-party devices, install them now. Otherwise, select Back.

Complete the Linux installation, following the instructions included with your operating system.

Continue with

Managing Your Storage Space on page 52

.

Installing with NetWare

Note: You will need your NetWare installation CD to complete this task.

To install the driver when installing NetWare:

1 Restart your computer, then install NetWare. (For instructions, refer to your NetWare documentation.)

2

To be able to load additional drivers later, select Manual install mode during the first part of the installation.

To load additional drivers: a Select Modify when the storage adapters are displayed.

b Select Storage adapters and press the Insert key to add an unlisted driver from the floppy disk.

When the Device Types screen appears, check the Storage adapters list and select Modify to add another driver.

3

4

5

6

7

Select Storage adapters, then press Enter.

All recognized controllers are displayed.

If AACRAID is detected, delete it.

Press Insert to add another driver.

The available drivers are displayed.

Insert the driver floppy disk.

Press the Insert key to scan the floppy disk drive.

Once the driver is selected, the Parameter screen is displayed.

Chapter 7: Installing the Driver and an Operating System ●

45

8

9

From the lower window menu, select Continue, then press Enter.

If the driver installation process fails, the server console is displayed so you can see the cause of the failure.

To modify disk partitions, apply hot fixes, or perform volume maintenance, refer to your

NetWare documentation.

Continue with

Managing Your Storage Space on page 52

.

Installing with OpenServer

Note: You will need your OpenServer installation CD to complete this task.

To install the driver when installing OpenServer:

1 Insert the OpenServer installation CD.

2

3

4

Restart your computer.

Follow the on-screen instructions to begin the OpenServer installation.

When prompted to load more HBA drivers, insert the driver disk, then select Yes. (To load more HBA drivers, repeat this step.)

5

6

7

When all drivers have loaded, select No.

Complete the OpenServer installation, following the instructions included with your operating system.

Continue with

Managing Your Storage Space on page 52

.

Installing with UnixWare

Note: You will need your UnixWare installation CD to complete this task.

To install the driver when installing UnixWare:

1 Insert the UnixWare installation CD.

2

3

4

Restart your computer.

Follow the on-screen instructions to begin the UnixWare installation.

When prompted to load more HBA drivers, insert the driver disk, then select Yes. (To load more HBA drivers, repeat this step.)

5

6

7

When all drivers have loaded, select No.

Complete the UnixWare installation, following the instructions included with your operating system.

Continue with

Managing Your Storage Space on page 52

.

Chapter 7: Installing the Driver and an Operating System ●

46

Installing with FreeBSD

Note: You will need your FreeBSD installation CD to complete this task.

To install the driver when installing FreeBSD:

1 Insert the FreeBSD installation CD.

2

3

Restart your computer.

When the FreeBSD start screen appears, select 6 to escape to loader prompt.

4

5

6

7

Type load kernel

.

Type load disk0:aacu.ko

.

If the driver fails to load, run lsdev and check for the floppy disk drive. Then, try again with the appropriate device.

Type boot

.

Complete the FreeBSD installation, following the instructions included with your operating system.

8

9

Reboot your computer, then remove the driver disk.

Repeat Steps

3 through 6 the first time you boot the operating system boot to load the

drivers again for the initial bootup.

10

Install the driver package permenantly, following the instructions in Installing on FreeBSD on page 51

.

11 Continue with

Managing Your Storage Space on page 52

.

Note: Currently, Adaptec Storage Manager is not supported on FreeBSD. To create and

manage arrays, use the Adaptec RAID Controller Utility (ACU). See page 54 for more

information.

Installing the Driver on an Existing

Operating System

8

In this chapter...

Before You Begin .................................................................................................................... 48

Creating a Driver Disk ........................................................................................................... 48

Installing on Windows ........................................................................................................... 49

Installing on Red Hat or SuSE Linux .................................................................................... 49

Installing on NetWare ............................................................................................................ 49

Installing on OpenServer ....................................................................................................... 50

Installing on UnixWare .......................................................................................................... 50

Installing on Solaris................................................................................................................ 51

Installing on FreeBSD ............................................................................................................ 51

This chapter explains how to install your Adaptec RAID controller driver.

Note: To install the driver while you’re installing an operating system, see

page 41 .

Chapter 8: Installing the Driver on an Existing Operating System ●

48

Before You Begin

Before you begin, install and connect your Adaptec RAID controller and internal disk drives

(see

page 31

).

You must also create a driver disk (see page 42 ) before you begin installing the controller driver.

Creating a Driver Disk

Note: You will need a floppy disk to complete this task.

To create a driver disk:

1 Set your system BIOS so that your computer boots from the CD drive. (For instructions, refer to your computer’s documentation.)

2

3

4

5

Turn on your computer, then insert the RAID Installation CD included in your RAID controller kit.

Follow the on-screen instructions to get to the Adaptec Start Menu.

Click Create Driver Disk, then select your operating system.

Linux only—Select your operating system and the architecture:

Intel 386 or 486 computers—Select i386.

Pentium I or II computers—Select i586.

Pentium III, IV, or AMD K-6 computers—Select i686.

AMD Athlon computers—Select Athlon.

Select your floppy disk drive letter, then select the format you want. (You need a full format only if your floppy disk has never been formatted or may have bad sectors.)

6

7

8

Insert the floppy disk, then click OK. The system creates the driver disk.

Remove and label the driver disk.

Continue the driver installation for your operating system:

For Windows, see

page 49 .

For Red Hat or SuSE Linux, see

page 49 .

For NetWare, see

page 49 .

For OpenServer, see page 50

.

For UnixWare, see page 50

.

For Solaris, see

page 51 .

For FreeBSD, see page 51

.

Chapter 8: Installing the Driver on an Existing Operating System ●

49

Installing on Windows

To install the driver on Windows:

1

2

3

4

5

6

Start or restart Windows.

The Found New Hardware Wizard opens and searches for the driver.

Insert the driver disk, select Floppy drive, then click Next.

Click Next, then click Next again.

Follow the on-screen instructions to complete the driver installation.

Remove the driver disk and restart your computer.

Continue with

Managing Your Storage Space on page 52

.

Installing on Red Hat or SuSE Linux

To install the module on Red Hat or SuSE Linux:

1 Insert and mount the RAID Installation CD:

2

Red Hat: mount /dev/cdrom /mnt/cdrom

SuSE: mount /dev/cdrom /media/cdrom

Install the module RPM: rpm -Uvh mount-point/xxx/yyy.rpm

3

4

5 where mount-point is the specific mount point on the Linux system, xxx is the driver path, and yyy.rpm

is the rpm file.

Reboot your computer to ensure the driver loaded correctly.

Run fdisk, mkfs, and create mount points for any new disk drives.

Continue with

Managing Your Storage Space on page 52

.

Installing on NetWare

Note: Before you begin, ensure that your NetWare OS has been upgraded to the minimum patch level specified by Novell. Refer to the Novell Web site for more information.

To install the driver on NetWare:

1 Start your computer.

2 At the NetWare server console prompt, type load hdetect

, then press Enter if it has not be loaded automatically.

3

4

5

6

7

At the Device types menu, select Continue, then press Enter.

At the Device type option, select Modify, then press Enter.

Select Storage Adapters, then press Enter.

At the Additional Driver Options menu, select Modify, then press Enter.

If aacraid.ham has already been detected, delete it.

Chapter 8: Installing the Driver on an Existing Operating System ●

50

8

9

At the Driver Name menu, press the Insert key.

Insert the driver disk, press the Insert key, then press F3.

10 At the A:\ prompt, press Enter.

The driver installs.

11 At the Additional Driver Option menu, select Return to driver summary, then press Enter.

12 At the Driver type menu, select Load on Additional Driver Options.

13 After the driver loads, select Continue.

14 Continue with

Managing Your Storage Space on page 52

.

Installing on OpenServer

To install the driver on OpenServer:

1

2

Start your computer, then insert the driver disk.

Begin the driver package installer: pkgadd -d diskette1

3

4

5

6

7

At the installer prompt, type go

.

Select 1 for the aacraid package.

When the installation is complete, select q to quit the installer.

Reboot your computer and remove the driver disk.

Continue with

Managing Your Storage Space on page 52

.

Installing on UnixWare

To install the driver on UnixWare:

1

2

Start your computer, then insert the driver disk.

Begin the driver package installer: pkgadd -d diskette1

3

4

5

6

7

At the installer prompt, type go

.

Select 1 for the aacraid package.

When the installation is complete, select q to quit the installer.

Reboot your computer and remove the driver disk.

Continue with

Managing Your Storage Space on page 52

.

Chapter 8: Installing the Driver on an Existing Operating System ●

51

Installing on Solaris

To install the driver on Solaris:

1

2

Start your computer.

Insert and mount the driver disk: volcheck

5

6

3

4

Change to the driver installer directory: cd /floppy/floppy0/DU/sol_210/i86pc/Tools

Start the driver installer:

./install.sh -i

Reboot your computer, then remove the driver disk.

Continue with

Managing Your Storage Space on page 52

.

Note: Currently, Adaptec Storage Manager is not supported on Solaris. To create and manage arrays, use the Adaptec RAID Controller Utility (ACU). See

page 54 for more information.

Installing on FreeBSD

To install the driver on FreeBSD:

1

2

Start your computer.

Insert and mount the driver disk:

3 mount -t msdos /dev/fd0 /mnt

Copy the driver package to the /tmp directory:

4 cp /mnt/aac-02.00.00-x.tgz /tmp

Install the driver package:

5

6 pkg_add aac-02.00.00-x.tgz

Reboot your computer, then remove the driver disk.

Continue with

Managing Your Storage Space on page 52

.

Note: Currently, Adaptec Storage Manager is not supported on FreeBSD. To create and

manage arrays, use the Adaptec RAID Controller Utility (ACU). See page 54 for more

information.

Managing Your Storage Space

9

In this chapter...

About Adaptec Storage Manager ........................................................................................... 53

About the Adaptec RAID Controller Configuration Utility ................................................ 53

About the Adaptec RAID Controller Utility ......................................................................... 54

About the Adaptec Flash Utility ............................................................................................ 54

Which Utility Should I Use? .................................................................................................. 54

Once you have installed your Adaptec RAID controller, disk drives (or other devices), and device driver, you can begin to build and manage your storage space.

This chapter introduces Adaptec Storage Manager, and describes the other utilities included with your Adaptec RAID controller.

Chapter 9: Managing Your Storage Space ●

53

About Adaptec Storage Manager

Adaptec Storage Manager is a full-featured software application that helps you build a storage space for your online data, using Adaptec RAID controllers and disk drives.

With Adaptec Storage Manager, you can group disk drives into logical drives and build in redundancy to protect your data and improve system performance.

You can also use Adaptec Storage Manager to monitor and manage all the controllers and disk drives in your storage space from a single location.

When Adaptec Storage Manager is installed on a computer, the Adaptec Storage Manager agent is also installed automatically. The agent is like a service that keeps your storage space running.

It’s designed to run in the background, without user intervention, and its job is to monitor and manage system health, event notifications, task schedules, and other on-going processes on that system. It sends notices when tasks are completed successfully, and sounds an alarm when errors or failures occur on that system.

The agent uses less memory than the full application. If your storage space includes systems that won’t be connected to monitors (and therefore won’t require the user interface), you can choose to run the agent only on those systems instead of the full application. For more information, refer to the Adaptec Storage Manager User’s Guide or online Help.

Installing Adaptec Storage Manager

Adaptec Storage Manager is included on the Adaptec Storage Manager Installation CD. For installation instructions, refer to the Adaptec Storage Manager User’s Guide, also included on the Adaptec Storage Manager Installation CD.

About the Adaptec RAID Controller Configuration Utility

The Adaptec RAID Controller Configuration Utility (ARCCONF) is a command line utility that you can use to perform some basic array and configuration management functions.

With ARCCONF, you can:

● Create and delete logical drives

Modify and copy configuration settings

Recover from disk drive failures and troubleshoot

ARCCONF and the Command Line Interface (CLI) User’s Reference, which describes how to use

ARCCONF, are included on the Adaptec Storage Manager Installation CD.

Note: Adaptec recommends that only advanced users familiar with command line interfaces use ARCCONF.

Chapter 9: Managing Your Storage Space ●

54

About the Adaptec RAID Controller Utility

The Adaptec RAID Controller utility is a BIOS-based utility that you can use to create and manage controllers, disk drives and other devices, and arrays. The Adaptec RAID Controller utility comprises these tools:

Array Configuration Utility (ACU)—For creating and managing arrays, and initializing and rescanning disk drives. (ACU for DOS is also available. See

page 83

.)

A -Select utility—SerialSelect, SATASelect®, or SCSISelect®, for modifying your controller and disk drive settings.

Disk Utilities—For formatting or verifying disk drives.

The Adaptec RAID Controller utility is included in your controller’s BIOS. For more information, see

Using the Adaptec RAID Controller Utility on page 75 .

Note: The Adaptec RAID Controller utility is primarily intended for pre-operating system installation configuration.

About the Adaptec Flash Utility

The Adaptec Flash Utility (AFU) is a text-based DOS utility that you can use to update, save, or verify your RAID controller’s firmware BIOS and Non-Volatile Random Access Memory

(NVRAM).

!

Caution: Although the AFU contains safeguards to prevent you from accidentally damaging your RAID controller’s flash contents, it is still important to use the AFU carefully and correctly to avoid rendering your RAID controller inoperable.

Adaptec recommends that only advanced users familiar with working in DOS use the AFU.

Which Utility Should I Use?

To create a bootable array, Adaptec recommends that you use the BIOS-based ACU (see

page 54

).

For all subsequent storage management tasks, Adaptec recommends that you install and use

Adaptec Storage Manager (see page 53 ). As a full-featured software application with a graphical

user interface, it is the easiest to use and offers the widest range of management functions.

Solving Problems

10

In this chapter...

Troubleshooting Checklist ..................................................................................................... 56

Silencing the Alarm ................................................................................................................ 56

Recovering from a Disk Drive Failure ................................................................................... 56

Resetting the Controller ......................................................................................................... 58

This chapter provides basic troubleshooting information and solutions for solving controller problems.

Chapter 10: Solving Problems ●

56

Troubleshooting Checklist

If you encounter difficulties installing or using your Adaptec RAID controller, check these items first:

With your computer powered off, check the connections to each disk drive, to the power supply, to the LED connector, and so on.

Try disconnecting and reconnecting disk drives from the Adaptec RAID controller.

Check that your Adaptec RAID controller installed in a compatible expansion slot (PCI,

PCI-X, or PCI-E). To double-check the bus compatibility of your controller, see About Your

RAID Controller on page 16

.

Ensure that your Adaptec RAID controller firmly seated and secured in the PCI/PCI-X/

PCI-E expansion slot.

If your Adaptec RAID controller is not detected during system boot, try installing it in a different compatible expansion slot. (See

page 32

for instructions.)

SCSI RAID controllers only—Ensure that each SCSI disk drive (or other device) on each

SCSI bus assigned a unique SCSI ID.

Check that termination set correctly on each SCSI bus.

Did the driver install correctly? ●

● If you have external disk drives (or other devices), are they powered on?

If you are still unable to resolve a problem, you can find additional troubleshooting information and direction on the Adaptec Web site at www.adaptec.com

or the Support

Knowledgebase at ask.adaptec.com

.

Silencing the Alarm

If your Adaptec RAID controller includes an alarm, the alarm will sound when an error occurs.

To silence the alarm, use Adaptec Storage Manager (see Managing Your Storage Space on page 52

.)

Recovering from a Disk Drive Failure

This section explains how to recover when a disk drive fails:

If the array was protected by a hot spare (see page 57 ).

If the array was not protected by a hot spare (see

page 57 ).

If there is a disk drive failure in more than one array simultaneously (see

page 57 ).

If it is a RAID 0 array (see page 57

).

If multiple disk drives fail within the same array (see

page 58 ).

Note: Adaptec Storage Manager uses the term logical drives when referring to arrays (see

page 12

).

Chapter 10: Solving Problems ●

57

Failed Disk Drive Protected by a Hot Spare

When an array is protected by a hot spare, if a disk drive in that array fails the hot spare is automatically incorporated into the array and takes over for the failed drive.

To recover from the failure:

1 Remove and replace the failed disk drive (following manufacturer’s instructions).

2 If copyback is not enabled—In Adaptec Storage Manager, remove the ‘hot spare’ designation from the original hot spare (the disk drive that was built into the array). Then, designate a new hot spare to protect the arrays on that controller.

If copyback is enabled—Data is automatically moved back to its original location once the controller detects that the failed drive has been replaced. No action is required.

Failed Disk Drive Not Protected by a Hot Spare

When a array is not protected by a hot spare, if a disk drive in that array fails, remove and replace the failed disk drive. The controller detects the new disk drive and begins to rebuild the array.

If the controller fails to rebuild the array, check that the cables, disk drives, and controllers are properly installed and connected. Then, if necessary, use Adaptec Storage Manager to rebuild the array. For instructions, refer to the Adaptec Storage Manager User’s Guide or online Help.

Failure in Multiple Arrays Simultaneously

If there’s a disk drive failure in more than one array at the same time (one failure per array), and the arrays have hot spares protecting them, the controller rebuilds the arrays with these limitations:

A hot spare must be of equal or greater size than the failed disk drive it’s replacing.

Failed disk drives are replaced with hot spares in the order in which they failed. (The array that includes the disk drive that failed first is rebuilt first, assuming an appropriate hot spare is available—see bullet above.)

If there are more disk drive failures than hot spares, see

Failed Disk Drive Not Protected by a Hot

Spare on page 57 .

If copyback is enabled, data is moved back to its original location once the controller detects that the failed drive has been replaced.

Disk Drive Failure in a RAID 0 Array

Because RAID 0 volumes do not include redundancy, if a disk drive fails in a RAID 0 array, the data can’t be recovered.

Correct the cause of the failure or replace the failed disk drives. Then, restore your data (if available).

Chapter 10: Solving Problems ●

58

Multiple Failures in the Same Array

Except in RAID 6 and RAID 60 arrays (see page 66

), if more than one disk drive fails at the same time in the same array, the data can’t be recovered.

Correct the cause of the failure or replace the failed disk drives. Then, restore your data (if available).

Note: In some instances, RAID 10 and RAID 50 arrays may survive multiple disk drive failures, depending on which disk drives fail. For more information, refer to the Adaptec Storage

Manager User’s Guide or online Help.

Resetting the Controller

This section explains how to reset (or flash) your Adaptec RAID controller. You may want to do this if the controller becomes inoperable, or if a firmware upgrade is unsuccessful.

To reset your Adaptec RAID controller:

1

2

Download the firmware version currently installed on your controller from www.adaptec.com

Extract the downloaded files to a folder on your local hard drive (for example,

C:\Download\Drivers).

3

4

Create a bootable MS–DOS floppy disk and copy the AFU.exe file to it. Copy the first firmware image to the same floppy disk.

Create additional bootable MS–DOS floppy disks and copy each additional firmware image to its own floppy disk.

5

6

7

8

Power off your computer, disconnect the power cord, then open the cabinet following the manufacturer’s instructions.

Disconnect all cables from the controller, then attach a shorting jumper to the Mode 0 flash connector. (To locate the Mode 0 flash connector on your Adaptec RAID controller,

see the figures in About Your RAID Controller on page 16

.)

Reconnect the power cord, power on your computer, then boot to the floppy disk containing the AFU.exe file (see

Step 3 ).

At the prompt, type a:\afu update /c x where x

is the controller number.

9 Insert the other floppy disks when prompted.

10 When the flash is complete, power off your computer, disconnect the power cord, then remove the jumper.

11 Close the computer cabinet, reconnect the power cord, then power on your computer.

The controller should boot correctly.

Introduction to Serial Attached

SCSI (SAS)

A

In this appendix...

Terminology Used in This Chapter ....................................................................................... 60

What is SAS? ........................................................................................................................... 60

How Do SAS Devices Communicate? ................................................................................... 61

What’s a Phy? .......................................................................................................................... 61

What’s a SAS Port?.................................................................................................................. 62

What’s a SAS Address?............................................................................................................ 62

What’s a SAS Connector? ....................................................................................................... 62

What do SAS Cables Look Like? ............................................................................................ 63

How are Disk Drives Identified in SAS? ................................................................................ 63

What are the SAS Connection Options? ............................................................................... 63

How is SAS Different from Parallel SCSI?............................................................................. 65

This section provides a basic overview of the main features of Serial Attached

SCSI (SAS), introduces some common SAS terms, and explains how SAS differs from parallel SCSI.

Note: For technical articles and tutorials about SAS, refer to the SCSI Trade Association

(STA

TM

) Web site at www.scsita.org.

Chapter A: Introduction to Serial Attached SCSI (SAS) ●

60

Terminology Used in This Chapter

For convenience, SAS HBAs and SAS RAID controllers are referred to generically in this chapter as SAS cards. HBAs, RAID controllers, disk drives, and external disk drive enclosures are referred to as end devices and expanders are referred to as expander devices.

For convenience, this chapter refers to end devices and expander devices collectively as SAS

devices.

What is SAS?

Legacy parallel SCSI is an interface that lets devices such as computers and disk drives communicate with each other. Parallel SCSI moves multiple bits of data in parallel (at the same time), using the SCSI command set.

Serial Attached SCSI (SAS) is an evolution of parallel SCSI to a point-to-point serial interface.

SAS also uses the SCSI command set, but moves multiple bits of data one at a time. SAS links end devices through direct-attach connections, or through expander devices.

SAS cards can typically support up to 128 end devices and can communicate with both SAS and SATA devices. (You can add 128 end devices—or even more—with the use of SAS

expanders. See page 64

.)

Note:

Although you can use both SAS and SATA disk drives in the same SAS domain (see page

64 ), Adaptec recommends that you not combine SAS and SATA disk drives within the same

array or logical drive. The difference in performance between the two types of disk drives may adversely affect the performance of the array.

Data can move in both directions simultaneously across a SAS connection (called a link—see

page 61 ). Link speed is 600 MB/sec in full-duplex mode. A SAS card with eight links has a

maximum bandwidth of 4800 MB/sec in full-duplex mode.

Although they share the SCSI command set, SAS is conceptually different from parallel SCSI physically, and has its own types of connectors, cables, connection options, and terminology, as described in the rest of this chapter.

To compare SAS to parallel SCSI, see

How is SAS Different from Parallel SCSI? on page 65 .

Chapter A: Introduction to Serial Attached SCSI (SAS) ●

61

How Do SAS Devices Communicate?

SAS devices communicate with each other through links. A link is a physical connection between two phys.

As shown in the following figure, SAS devices contain ports (see

page 62 ), ports contain phys,

and each phy contains one transmitter and one receiver—one transceiver. A phy can belong to one port only.

SAS Device

Narrow

Port

Phy

Receiver

Transmitter link

SAS Device

Transmitter

Receiver

Phy

Narrow

Port

SAS Device

Wide

Port

Phy

Receiver

Transmitter

Phy

Receiver

Transmitter

Transmitter

Receiver

Phy

Transmitter

Receiver

Phy

Wide

Port

Wide

Port

Phy

Receiver

Transmitter

Phy

Receiver

Transmitter

Phy

Receiver

Transmitter

Phy

Receiver

Transmitter

SAS Device

Transmitter

Receiver

Phy

Transmitter

Receiver

Phy

Transmitter

Receiver

Phy

Transmitter

Receiver

Phy

Wide

Port

What’s a Phy?

Phys are part of the physical communication connection between SAS devices. Each phy contains a transceiver that sends data back and forth between SAS devices.

When a connection is formed between two end devices, a link is established from a phy in one port to a phy in the other port. As shown in the figure above, a wide port can support multiple independent links simultaneously.

Phys are internal, within SAS connectors (see page 62

).

SAS cables physically connect one or more phys on one SAS device to one or more phys on another SAS device.

Chapter A: Introduction to Serial Attached SCSI (SAS) ●

62

What’s a SAS Port?

Note: Because the physical link between SAS devices is from phy to phy, rather than port to port, a “port” is more of a virtual concept, different from what is normally considered a port on other types of RAID controllers and storage devices.

A port is one or more phys. A narrow port contains one phy. A wide port typically contains four phys.

Each port has its own unique SAS address (see page 63

), and all the phys in a port share that same SAS address.

SAS card port options vary. A SAS card with four phys could be configured with one wide port, with two wide ports that comprise two phys, or with four narrow ports each containing one phy. (A wide port with four phys is referred to as a 4-wide or 4x port.)

What’s a SAS Address?

Each SAS port is identified with a unique SAS address, which is shared by all phys on that port.

For example, a SAS disk drive might have two narrow ports. Each port has one unique SAS address. The single phy in each port uses its port’s SAS address.

In another example, a SAS device might have one 4-wide port. That port has one SAS address, which is shared by all four phys in the port.

Unlike SCSI devices and SCSI IDs, SAS devices self-configure their SAS addresses. User intervention is not required to set SAS addresses, and SAS addresses cannot be modified.

What’s a SAS Connector?

A SAS connector is the physical plug or receptacle that you see on a SAS device. It supports the power and signal line cable. It’s what you plug a SAS cable into, or the end of the SAS cable that’s being plugged in.

A connector is what forms physical links between phys.

SAS fan-out cable

4-wide internal SAS connector

External SAS connector

Single-port connector

External SAS cable

Some SAS connectors can support multiple links. The number of links a SAS connector can support is referred to as its width. Narrow connectors support a single link; wide connectors support up to four links.

A single SAS device may have one or more connectors. A single SAS connector may help form links between more than two SAS devices. (For instance, as shown in the figure above, the 4wide internal SAS connector forms links with four independent disk drives.)

Chapter A: Introduction to Serial Attached SCSI (SAS) ●

63

What do SAS Cables Look Like?

Internal SAS cables are narrower than internal parallel SCSI cables. The connectors vary in size depending on the number of links they support, from single link connectors to 4-wide (or larger) connectors. Internal fan-out cables (shown in the next figure) let you attach four disk drives to a single 4-wide connector.

4x wide-to-4x wide internal SAS cable

Internal SAS-to-SATA fan-out cable (SAS-to-SAS fan-out cables are also available)

External SAS cable

An example of some internal SAS cables and an external SAS cable are shown in the figure above.

How are Disk Drives Identified in SAS?

In the BIOS and in the management utilities (see

page 52

), disk drives are identified with numbers in this format:

XX:YY:ZZ where XX is the disk drive count number, YY is the enclosure number, and ZZ is the slot number (within the enclosure). If the disk drive is not installed in an enclosure, a double dashes (--) appear instead of YY and ZZ (for instance, 01:--:--).

In parallel SCSI, XX is the disk drive’s channel number, YY is the target number, and ZZ is the logical unit number (LUN).

What are the SAS Connection Options?

You can connect end devices to each other through direct cable connections and through backplane connections. When you use one or more expander devices (see

page 64 ), you can

create large configurations.

Direct-attach Connections

In a direct-attach connection, SAS or SATA disk drives are connected directly to a SAS card with SAS cables. One disk drive is attached to one SAS connector with one SAS cable (or multiple disk drives are attached to one SAS connector with one fan-out cable). The figure on

page 62 shows an example of direct-attach connections.

The number of direct-attached disk drives is limited to the number of phys supported by the

SAS card. (Note that there may be multiple phys within a single connector. See

page 63 .)

Chapter A: Introduction to Serial Attached SCSI (SAS) ●

64

Backplane Connections

In a backplane connection, disk drives and SAS cards are attached to and communicate with each other through a system backplane.

The number of end devices is limited to the number of slots available on the backplane. For example, the Adaptec S50 enclosure, which contains an expander, is a backplane connection that supports up to 12 SAS or SATA disk drives.

Some backplanes support daisy-chain expansion to other backplanes. For example, you can daisy-chain (connect one to the next) up to nine Adaptec S50 enclosures to a single SAS card in a host system.

SAS Expander Connections

A SAS expander device literally expands the number of end devices that you can connect

together. Expander devices, typically embedded into a system backplane (see page 64

), support large configurations of SAS end devices, including SAS cards and SAS and SATA disk drives.

With expander devices, you can build large and complex storage topologies.

There are two types of SAS expanders: fanout expanders and edge expanders. Each performs a different role in a storage system. (For more information about how SAS expanders work, refer to the STA Web site at www.scsita.org.)

You can connect up to 128 SAS ports to an edge expander. (A single edge expander can therefore support up to 128 SAS addresses.)

You can connect up to 128 edge expanders to a fanout expander.

You can use only one fanout expander in any single SAS domain (a topology of SAS—and possibly SATA—end devices and expander devices). A single SAS domain can therefore comprise up to 16,384 SAS ports (and therefore up to 16,384 SAS addresses).

The next figure illustrates (in very basic terms) a SAS domain and shows how SAS cards, SAS and SATA disk drives, and expander devices can fit together in a large data storage topology.

Disk Drives

SAS

SAS SATA

Disk Drives

SATA

Disk Drives

SATA SAS

Fanout Expander

SAS Card

SAS SATA

Disk Drives

SAS Card

SAS SATA

Disk Drives

SATA

Disk Drives

SATA

SAS Card

SATA

Disk Drives

SAS

Chapter A: Introduction to Serial Attached SCSI (SAS) ●

65

How is SAS Different from Parallel SCSI?

In summary, although SAS and parallel SCSI both use the SCSI command set, how they move data from one place to another is very different. To support point-to-point serial data transport, SAS introduces new types of connectors, cables, connection options, and terminology.

Generally speaking, SAS is faster and more flexible than parallel SCSI, and provides more options for building your storage space. SAS lets you mix SAS and SATA disk drives together, and lets you connect many, many more devices.

This table describes many of the main differences between the two interfaces.

Parallel SCSI

Parallel interface

Maximum speed 320 MB/sec shared by all devices on the bus

Supports SCSI devices only

Up to 16 devices per SCSI channel

Supports single-port devices only

Uses SCSI IDs to differentiate between devices connected to the same adapter

User intervention required to set SCSI IDs

Requires bus termination

Standard SCSI connectors

Serial Attached SCSI

Serial interface

Maximum speed 600 MB/sec per phy when in fullduplex mode

Supports SATA and SAS disk drives simultaneously

More than 128 disk drives per SAS card, using an

expander (see page 64

)

Supports single- and dual-port devices

Uses unique SAS addresses to differentiate between devices

SAS addresses self-configured by SAS devices

Requires no bus termination

SAS connectors (see

page 63

)

Understanding RAID

B

In this appendix...

Understanding Drive Segments............................................................................................. 67

RAID 0 (Non-RAID Arrays).................................................................................................. 67

RAID 1 Arrays ........................................................................................................................ 68

RAID 1 Enhanced Arrays ....................................................................................................... 68

RAID 10 Arrays ...................................................................................................................... 69

RAID 5 Arrays ........................................................................................................................ 70

RAID 5EE Arrays.................................................................................................................... 71

RAID 50 Arrays ...................................................................................................................... 72

RAID 6 Arrays ........................................................................................................................ 73

RAID 60 Arrays ...................................................................................................................... 73

Selecting the Best RAID Level................................................................................................ 74

When you create arrays (or logical drives), you can assign a RAID level to protect your data.

Each RAID level offers a unique combination of performance and redundancy. RAID levels also vary by the number of disk drives they support.

This appendix describes the RAID levels supported by your Adaptec RAID controller, and provides a basic overview of each to help you select the best level of protection for your data storage.

Appendix B: Understanding RAID ●

67

Understanding Drive Segments

A drive segment is a disk drive or portion of a disk drive that is used to create an array. A disk drive can include both RAID segments (segments that are part of an array) and available segments. Each segment can be part of only one logical device at a time. If a disk drive is not part of any logical device, the entire disk is an available segment.

RAID 0 (Non-RAID Arrays)

An array with RAID 0 includes two or more disk drives and provides data striping, where data is distributed evenly across the disk drives in equal-sized sections.

RAID 0 arrays do not maintain redundant data, so they offer no data protection. However, compared to an equal-sized group of independent disks, a RAID 0 array provides improved I/

O performance.

Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an array with two 250 GB disk drives and two 400 GB disk drives can create a RAID 0 drive segment of 250 GB, for a total of 1000 GB for the volume, as shown in this figure.

Disk Drive 1 250 GB

Drive Segment Size

(Smallest Disk Drive)

Disk Drive 2 250 GB

Disk Drive 3 400 GB

Disk Drive 4 400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 5 ...

997

Disk Drive 2 2 6 ...

998

Disk Drive 3 3 7 ...

999

Unused Space = 150 GB

Disk Drive 4 4 8 ... 1000

Unused Space = 150 GB

RAID 0 Logical Drive = 1000 GB

Appendix B: Understanding RAID ●

68

RAID 1 Arrays

A RAID 1 array is built from two disk drives, where one disk drive is a mirror of the other (the same data is stored on each disk drive). Compared to independent disk drives, RAID 1 arrays provide improved performance, with twice the read rate and an equal write rate of single disks.

However, capacity is only 50 percent of independent disk drives.

If the RAID 1 array is built from different- sized disk drives, the free space, drive segment size is the size of the smaller disk drive, as shown in this figure.

Drive Segment Size

(Smallest Disk Drive)

Disk Drive 1 250 GB

Disk Drive 2 400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 – 250

Disk Drive 2 1 – 250

Unused Space = 150 GB

RAID 1 Logical Drive = 250 GB

RAID 1 Enhanced Arrays

A RAID 1 Enhanced (RAID 1E) array—also known as a striped mirror—is similar to a RAID 1 array except that data is both mirrored and striped, and more disk drives can be included. A

RAID 1E array can be built from three or more disk drives—depending on the stripe size, the maximum number of disk drives ranges from eight to sixteen.

In this example, the large bold numbers represent the striped data, and the smaller, non-bold numbers represent the mirrored data stripes.

Disk Drive 1 400 GB

Disk Drive 2 400 GB

Disk Drive 3 400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 3 4 6

Disk Drive 2 2 1 5 4

Disk Drive 3 3 2 6 5

RAID 1E Logical Drive = 600 GB

Appendix B: Understanding RAID ●

69

RAID 10 Arrays

A RAID 10 array is built from two or more equal-sized RAID 1 arrays. Adaptec RAID controllers support a maximum number of 128 disk drives in a RAID 10 array.

Data in a RAID 10 array is both striped and mirrored. Mirroring provides data protection, and striping improves performance.

Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an array with two 250 GB disk drives and two 400 GB disk drives can create two mirrored drive segments of 250 GB, for a total of 500 GB for the array, as shown in this figure.

Disk Drive 1 250 GB

Drive Segment Size

(Smallest Disk Drive)

Disk Drive 2 250 GB

Disk Drive 3 400 GB

Disk Drive 4 400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 3 ...

499

Disk Drive 2 2 4 ...

500

Disk Drive 3 1 3 ...

499

Unused Space = 150 GB

Disk Drive 4 2 4 ...

500

Unused Space = 150 GB

RAID 10 Logical Drive = 500 GB

Appendix B: Understanding RAID ●

70

RAID 5 Arrays

A RAID 5 array is built from a minimum of three and a maximum of sixteen disk drives, and uses data striping and parity data to provide redundancy. Parity data provides data protection, and striping improves performance.

Parity data is an error-correcting redundancy that’s used to re-create data if a disk drive fails. In

RAID 5 arrays, parity data (represented by Ps in the next figure) is striped evenly across the disk drives with the stored data.

Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an array with two 250 GB disk drives and two 400 GB disk drives can contain 750 GB of stored data and 250 GB of parity data, as shown in this figure.

Disk Drive 1 250 GB

Drive Segment Size

(Smallest Disk Drive)

Disk Drive 2 250 GB

Disk Drive 3 400 GB

Disk Drive 4 400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 4 ...

P

Disk Drive 2 2 5 ...

748

Disk Drive 3 3 P ...

749

Unused Space = 150 GB

Disk Drive 4 P 6 ...

750

Unused Space = 150 GB

RAID 5 Logical Drive = 750 GB plus Parity

Appendix B: Understanding RAID ●

71

RAID 5EE Arrays

A RAID 5EE array—also known as a hot space—is similar to a RAID 5 array except that it includes a distributed spare drive and must be built from a minimum of four disk drives. The maximum number of disk drives is sixteen.

Unlike a hot spare, a distributed spare is striped evenly across the disk drives with the stored data and parity data, and can’t be shared with other logical disk drives. A distributed spare improves the speed at which the array is rebuilt following a disk drive failure.

A RAID 5EE array protects your data and increases read and write speeds. However, capacity is reduced by two disk drives’ worth of space, which is for parity data and spare data.

In this figure, S represents the distributed spare, P represents the distributed parity data.

Disk Drive 1 250 GB

Drive Segment Size

(Smallest Disk Drive)

Disk Drive 2 250 GB

Disk Drive 3 400 GB

Disk Drive 4 400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 S ...

P

Disk Drive 2 2 P ...

449

Disk Drive 3 S 3 ...

S

Unused Space = 150 GB

Disk Drive 4 P 4 ...

500

Unused Space = 150 GB

RAID 5EE Logical Drive = 750 GB plus

Parity and Spare

Appendix B: Understanding RAID ●

72

RAID 50 Arrays

A RAID 50 array is built from six to forty-eight disk drives configured as two or more RAID 5 arrays, and stripes stored data and parity data across all disk drives in both RAID 5 arrays. (For

more information, see RAID 5 Arrays on page 70 .)

Note: Because the Adaptec 2420SA RAID controller doesn’t support more than four disk drives, it doesn’t support RAID 50 arrays.

The parity data provides data protection, and striping improves performance. RAID 50 arrays also provide high data transfer speeds.

Drive segment size is limited to the size of the smallest disk drive in the array. For example, three 250 GB disk drives and three 400 GB disk drives comprise two equal-sized RAID 5 arrays with 500 GB of stored data and 250 GB of parity data. The RAID 50 array can therefore contain

1000 GB (2 x 500 GB) of stored data and 500 GB of parity data.

RAID 50

Logical Drive

=

1000 GB plus Parity

RAID 5

A

Each RAID 5 Logical Drive has

500 GB Data Storage

250 GB Parity Data

RAID 5

B

1, 5, P

Drive 1

250 GB

3, P, 9

Drive 2

250 GB

P, 7, 11

Drive 3

250 GB

2, 6, P

Drive 4

400 GB

4, P, 10

Drive 5

400 GB

P, 8, 12

Total Unused

Space = 150 GB

Drive 6

400 GB

In the example above, P represents the distributed parity data.

Appendix B: Understanding RAID ●

73

RAID 6 Arrays

A RAID 6 array—also known as dual drive failure protection—is similar to a RAID 5 array because it uses data striping and parity data to provide redundancy. However, RAID 6 arrays include two independent sets of parity data instead of one. Both sets of parity data are striped separately across all disk drives in the array.

RAID 6 arrays provide extra protection for your data because they can recover from two simultaneous disk drive failures. However, the extra parity calculation slows performance

(compared to RAID 5 arrays).

RAID 6 arrays must be built from four or more disk drives, to a maximum of sixteen.

Maximum stripe size depends on the number of disk drives in the array.

Disk Drive 1 250 GB

Drive Segment Size

(Smallest Disk Drive)

Disk Drive 2 250 GB

Disk Drive 3

Disk Drive 4

400 GB

400 GB

Disk Drives in Logical Drive

Disk Drive 1 1 P1 ...

P2

Disk Drive 2 2 P2 ... 449

Disk Drive 3 P1 3 ...

P1

Unused Space = 150 GB

Disk Drive 4 P2 4 ... 500

Unused Space = 150 GB

RAID 6 Logical Drive = 750 GB plus

Parity (P1 & P2)

RAID 60 Arrays

Similar to a RAID 50 array (see

page 72

), a RAID 60 array—also known as dual drive failure protection—is built from eight disk drives configured as two or more RAID 6 arrays, and stripes stored data and two sets of parity data across all disk drives in both RAID 6 arrays.

Note: Because the Adaptec 2420SA RAID controller doesn’t support more than four disk drives, it doesn’t support RAID 60 arrays.

Two sets of parity data provide enhanced data protection, and striping improves performance.

RAID 60 arrays also provide high data transfer speeds.

Appendix B: Understanding RAID ●

74

Selecting the Best RAID Level

Use this table to select the RAID levels that are most appropriate for the logical drives on your storage space, based on the number of available disk drives and your requirements for performance and reliability.

RAID level

RAID 0

RAID 1

RAID 1E

RAID 10

RAID 5

RAID 5EE

RAID 50

1

RAID 6

RAID 60

*

Redundancy

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Disk Drive

Usage

100%

50%

50%

50%

67 – 94%

50 – 88%

67 – 94%

50 – 88%

50 – 88%

Read

Performance

ŠŠŠ

ŠŠ

ŠŠ

ŠŠ

ŠŠŠ

ŠŠŠ

ŠŠŠ

ŠŠ

ŠŠ

Write

Performance

ŠŠŠ

ŠŠ

ŠŠ

ŠŠ

Š

Š

Š

Š

Š

Built-in Hot

Spare

No

No

No

No

No

Yes

No

No

No

Minimum

Disk Drives

2

2

3

4

3

4

6

4

8

1 Because it supports a maximum of four disk drives, the Adaptec 2420SA RAID controller can’t support RAID 50 or RAID 60.

Disk drive usage, read performance, and write performance depend on the number of drives in the logical drive. In general, the more drives, the better the performance.

Using the Adaptec RAID Controller

Utility

C

In this appendix...

Introduction to the Adaptec RAID Controller Utility ......................................................... 76

Running the Adaptec RAID Controller Utility..................................................................... 76

Using the ACU to Create and Manage Arrays ...................................................................... 76

Using the -Select Utility to Modify Controller Settings ....................................................... 78

Formatting and Verifying Disk Drives .................................................................................. 82

Viewing the Event Log ........................................................................................................... 82

The Adaptec RAID Controller utility is a BIOS-based utility that you can use to create and manage controllers, disk drives and other devices, and arrays.

Note: Adaptec recommends that only advanced users familiar with working in a computer BIOS use the Adaptec RAID Controller utility tools. For more information, see

Managing Your Storage

Space on page 52 .

Appendix C: Using the Adaptec RAID Controller Utility ●

76

Introduction to the Adaptec RAID Controller Utility

The Adaptec RAID Controller utility comprises these tools:

The Array Configuration Utility (ACU)—For creating and managing arrays, and initializing and rescanning disk drives (see

page 76 ).

Note:

Also available—ACU for DOS. See page 83

.

A -Select Utility—SerialSelect, SATASelect, or SCSISelect, for modifying your controller and disk drive settings (see

page 78 ).

Disk Utilities—For formatting or verifying disk drives (see

page 82 ).

Running the Adaptec RAID Controller Utility

If your Adaptec controller is connected to a RAID enclosure, power on your enclosure (or enclosures) before you power on your computer.

Start or restart your computer. When prompted, press Ctrl+A.

Note: The first time you power on your computer after you install a new controller, the BIOS may display a configuration that doesn’t match your system’s configuration. This is normal.

Navigating the Adaptec RAID Controller Utility

All the tools within the Adaptec RAID Controller utility are menu-based and instructions for completing tasks appear on-screen. Menus can be navigated using the arrows, Enter, Esc, and other keys on your keyboard.

Using the ACU to Create and Manage Arrays

To open the ACU, start the Adaptec RAID Controller utility (see page 76 ). If you have more than

one controller, select your controller, then press Enter. Select Array Configuration Utility, then press Enter.

Follow the on-screen instructions to create and manage arrays, and initialize, rescan, and erase disk drives.

Creating a New Array

To begin creating an array, select Create Arrays from the main ACU menu.

Only disk drives that can be used in a new array are available for selection. (Disk drives must be initialized before they can be used in an array. See

Initializing Disk Drives on page 77 for more

information.)

Use the Array Properties menu to modify the array’s RAID level, size, name, stripe size, and caching settings.

Note: For more information about RAID levels and using disk drives to create arrays, see

Choosing a RAID Level on page 27

.

Appendix C: Using the Adaptec RAID Controller Utility ●

77

Managing Existing Arrays

To view or modify existing arrays, select Manage Arrays from the main ACU menu.

From the Manage Arrays menu, you can:

● View the properties of an array.

Note: Failed drives are displayed in a different text color.

Make an array bootable (see

Creating Bootable Arrays on page 77

).

Assign or remove hot spares.

Delete an array.

!

Caution: Before deleting an array, back up the data to avoid permanently losing it.

Creating Bootable Arrays

Note: You may need to change the system BIOS to modify the boot order. For more information, refer to your computer’s documentation.

The controller always uses the lowest numbered array as its bootable array.

To make an array bootable:

1

2

Select Manage Arrays from the main ACU menu.

Select the array that you want to make bootable, then press Ctrl+B.

Note: You cannot make an array bootable while it’s building, verifying, or rebuilding.

3

The array’s number changes to Array 00, which makes this array the controller’s boot array.

Restart your computer.

Initializing Disk Drives

If a disk drive appears grayed-out (unavailable for use in a new array), it may need to be initialized.

To begin initializing a disk drive, select Initialize Drives from the main ACU menu.

!

Caution: Do not initialize a disk drive that is part of an array. Initializing a disk drive that’s part of an array may make the array unusable.

Back up all data from your disk drive before you initialize it.

Rescanning Disk Drives

To begin rescanning a disk drive, select Rescan Drives from the main ACU menu.

Appendix C: Using the Adaptec RAID Controller Utility ●

78

Secure Erasing Disk Drives

When you perform a secure erase on a disk drive, all data on that disk drive is completely and irretrievably eradicated. Secure erase performs three distinct writing passes to the disk drive being erased—it does not just write zeros.

Performing a secure erase takes up to six times longer than clearing (or zeroing) a disk drive.

You may want to perform a secure erase only on disk drives that contain confidential or classified information.

Note: To erase (or zero) a disk drive with non-classified information, you may choose to format it (see

page 82

) instead, or clear it using Adaptec Storage Manager—both options take much less time than the secure erase option.

To begin a secure erase, select Secure Erase from the main ACU menu, then select Y (yes). To return to the main ACU menu once the secure erase has begun, press Esc.

The selected disk drive(s) cannot be used until the erase is complete.

Stopping a Secure Erase

To stop a secure erase in progress:

1

2

In the main ACU window, select Secure Erase.

Select the disk drive being secure erased, then press Ctrl+Q.

The secure erase stops and the ACU returns to its main window.

Using the -Select Utility to Modify Controller Settings

Included in the Adaptec RAID Controller utility is a tool for modifying the settings of your controller and the disk drives connected to it. This utility is called SerialSelect, SATASelect, or

SCSISelect, depending on what type of controller you have.

Opening a -Select Utility

To open a -Select utility, start the Adaptec RAID Controller utility (see page 76

), select the

-Select utility, then press Enter.

Follow the on-screen instructions to modify the settings of your controller and connected disk drives as required.

Applying Changes and Exiting

1 To exit a -Select utility, press Esc until you are prompted to exit.

2

If you modified any settings, you are prompted to save the changes before you exit.

Select Yes to exit, then press any key to restart your computer.

Any changes you made take effect after the computer restarts.

Appendix C: Using the Adaptec RAID Controller Utility ●

79

Modifying Your Controller’s Configuration

Note: Default controller settings are suitable for most computers. Adaptec recommends that you do not change the default setting.

To modify your controller’s settings, select Controller Configuration from the main -Select utility menu.

The table on page 79 lists controller configuration options. Some options may not be available

for your controller. Additional, controller-specific options are also available:

For SAS controller-specific settings, see page 80

.

For SATA controller-specific settings, see

page 80 .

For SCSI controller-specific settings, see

page 81 .

General Controller Settings

Note: Default settings are shown in bold type.

Option

Drive’s Write Cache

Runtime BIOS

Automatic Failover

Array Background

Consistency Check

BBS Support

Array-based BBS

Support

Physical Drives Display

During POST

Description

When enabled, write cache is enabled on the disk drive. When disabled, write cache is not used on the disk drive. Default is the disk drive’s setting.

Caution—When write cache is enabled, there is a slight possibility of data loss or corruption during a power failure.

When enabled, the controller BIOS allows the controller to act as a bootable device. Disabling the BIOS allows another controller to act as a bootable device.

When enabled, the controller automatically rebuilds an array when a failed disk drive is replaced. When disabled, the array must be rebuilt manually.

When enabled, the controller constantly verifies a redundant array. Note that there may be a significant performance reduction. Default is disabled.

When enabled in systems that support BBS, the RAID controller is presented as a bootable device in the BIOS.

When enabled in systems that support BBS, the controller presents attached bootable devices up to the BIOS for boot device selection. This is relevant for logical arrays. Default is disabled.

When enabled, connected disk drives are displayed during system Power

On Self Test (POST). Displaying the disk drives adds a few seconds to the overall POST time. Default is disabled.

CD-ROM Boot Support When enabled, the system can be booted from a bootable CD. (This setting is not available on all RAID controller models.)

Note—CD-ROMs are not supported by current software.

Removable Media

Devices Boot Support

When enabled, removable media devices, such as CD drives, are supported. (This setting is not available on all RAID controller models.)

Alarm Control When enabled, the alarm sounds. Default is enabled.

Appendix C: Using the Adaptec RAID Controller Utility ●

80

SAS-specific Controller Settings

In addition to the general settings listed on page 79 , your Adaptec SAS controller has SAS-

specific settings that can be modified if required. (For more information about SAS, see

page 59

.)

To modify SAS-specific settings, select PHY Configuration from the SerialSelect main menu.

Note: Default settings are shown in bold type.

Option

PHY Rate

Description

The data transfer rate between the controller and devices. The default setting is

Auto, which allows the SAS card to adjust the data transfer rate as required.

CRC Checking When enabled, determines whether the controller verifies the accuracy of data transfer on the serial bus. Default setting is Yes (enabled). Set to No (disabled)

only if the controller is connected to a device that does not support CRC Checking.

SAS Address In a situation where you want each phy on a controller to be in a different SAS domain, this setting specifies a unique world-wide name for each phy. Default is 0.

Note: This setting is for SAS address conflict resolution only and should otherwise remain at its default value.

SATA-specific Controller Settings

In addition to the general settings listed on

page 79 , your Adaptec SATA controller has a SATA-

specific setting that can be modified if required.

Option

Write Cache

Description

When enabled, the controller’s write cache is enabled. Default is Yes (enabled).

Caution—When enabled, there is a potential for data loss or corruption during a power failure.

Appendix C: Using the Adaptec RAID Controller Utility ●

81

SCSI-specific Controller Settings

In addition to the general settings listed on

page 79 , your Adaptec SCSI controller has SCSI-

specific settings that can be modified if required.

To modify SCSI-specific settings, select SCSI Configuration from the SCSISelect main menu.

SCSI Device Settings

You can use SCSISelect to modify some of the settings on the SCSI devices connected to your

SCSI controller.

To modify SCSI device settings, select SCSI Configuration from the SCSISelect main menu, then select Additional Options. Devices are listed by SCSI ID. (To find the SCSI ID for a

specific device, see Formatting and Verifying Disk Drives on page 82

.)

For the best device performance, don’t change the default settings.

Note: Default settings are shown in bold type.

Option

Maximum

Transfer Rate

Enable

Disconnection

Initiate Wide

Negotiation

QAS

Packetized

Description

Shows the maximum data transfer rate that the SCSI channel supports.

When enabled, the SCSI device can disconnect from the SCSI channel. Default is

Yes (enabled).

When enabled, the SCSI channel attempts 16-bit data transfer instead of 8-bit data transfer. Default is Yes (enabled).

When enabled, QAS (Quick Arbitration and Selection) is used to eliminate overhead and speed up data transfers on the SCSI bus. Default is No (disabled).

Note—Adaptec recommends that you do not enable QAS if you are using an enclosure that supports Ultra320 expanders.

When enabled, SCSI packetization (encapsulation) is used to reduce overhead and speed data transfer. Default is Yes (enabled).

SCSI Channel Interface Settings

Note: Default settings are shown in bold type.

Option

Controller SCSI

Channel ID

SCSI Parity

Checking

Controller SCSI

Channel

Termination

Description

Sets the controller’s SCSI ID. Adaptec recommends that you leave the controller set to the default (7), which gives it the highest priority on the SCSI channel.

When enabled, the controller verifies the accuracy of data transfer on the SCSI channel. Disable only if the controller is connected to any SCSI device that does not support SCSI parity. Default is enabled.

Sets termination on the controller. Adaptec recommends that you retain the default setting (auto mode).

Appendix C: Using the Adaptec RAID Controller Utility ●

82

Formatting and Verifying Disk Drives

You can use the disk utilities to low-level format or verify your disk drives. (New disk drives are low-level formatted at the factory and do not need to be low-level formatted again.)

!

Caution: Before you format a disk drive, back up all data. Formatting destroys all data on a disk drive.

To format or verify a disk drive:

1

Start the Adaptec RAID Controller utility (see page 76

).

2

3

Select the controller you want, press Enter.

Select Disk Utilities.

4

5

Select the disk drive you want, then press Enter.

Select Format Disk or Verify Disk Media.

Viewing the Event Log

The BIOS-based event log records all firmware events, such as configuration changes, array creation, and boot activity.

Some events are not stored indefinitely—the event log is cleared of any non-persistent events each time you restart your computer; additionally, once the log is full, new events overwrite old events.

To view the event log:

1

Start the Adaptec RAID Controller utility (see page 76

).

2

3

4

Select the controller you want, press Enter.

When the Adaptec RAID Controller utility menu appears, press Ctrl+P.

Select Controller Log Information, then press Enter.

The current event log opens.

Using the ACU for DOS

D

In this appendix...

Getting Started ....................................................................................................................... 84

Working in the ACU Using Menus........................................................................................ 84

Running the ACU Using Scripts............................................................................................ 85

This chapter describes the Array Configuration Utility (ACU) for DOS, a text-based utility that you can use to create, configure, and manage arrays. (A BIOS-based ACU is also available. See

page 76 .)

Note: Adaptec recommends that only advanced users familiar with working in DOS use the

ACU for DOS utility. For more information, see Managing Your Storage Space on page 52 .

Appendix D: Using the ACU for DOS ●

84

Getting Started

Note: You need a bootable floppy disk to complete this task.

The ACU for DOS runs from a floppy disk which you can create using the RAID Installation

CD that came in your Adaptec RAID controller kit.

To create the ACU floppy disk:

1 Insert your RAID Installation CD into the CD drive, then browse to this file:

2

3 packages/firmware/controllermodel/acu.exe

Where controllermodel is the model number of your Adaptec RAID controller.

Insert a bootable floppy disk and copy the acu.exe file to it.

Continue either of these two ways:

Work in the ACU using menus (see the following section)

Run the ACU using scripts (see

page 85 )

Working in the ACU Using Menus

To work in the ACU using menus:

1

2

Insert the ACU floppy disk (see Getting Started

above), then start or restart your computer.

The computer boots to the DOS command line.

Type

ACU

on the command line, then press Enter.

The ACU is menu-based and instructions for completing tasks appear on-screen. Menus can be navigated using the arrow, Enter, Esc, and other keys on your keyboard.

For more information about completing tasks, see Using the ACU to Create and Manage

Arrays on page 76

.

Appendix D: Using the ACU for DOS ●

85

Running the ACU Using Scripts

To work in the ACU using scripts:

1

2

Insert the ACU floppy disk (see

page 84 ), then start or restart your computer.

The computer boots to the DOS command line.

Type

ACU

on the command line, specify a script file, and specify either the /P or /R switches listed in the following table. (Don’t specify both.)

You may also add one or both of the optional switches.

Note: Command line syntax is not case sensitive.

Switch

/P <file>

/R <file>

/L <file>

Description

Playback Mode—The ACU reads the contents of the specified script file and creates arrays and configures channel settings based on the keywords

defined in the script. See page 85 .

Record Mode—The ACU writes a RAID controller’s existing array configuration to a specified script file, which lets you create the same configuration by running the ACU in playback mode (/P switch) with the resulting script. See

page 86

.

(Optional) Log Filename Switch—If you include this switch, the ACU records its activity and any errors it encounters in the log file. If you do not include this switch, the ACU displays activity and errors on the screen.

The file is a standard MS-DOS file, which can include a drive, directory, filename, and extension. Only the filename and extension (.log) are required. If no drive or directory is specified, the file is placed in the same location as the

ACU executable.

/C <number> (Optional) Controller Number Switch—In systems with more than one controller, this switch specifies which controller to change, where number is the controller number. The default controller number is 0.

Note—The number assigned to a particular controller depends on the controller’s physical PCI slot and the order in which your system scans its PCI slots.

About Playback Mode

In this mode, the ACU reads the contents of the specified script file and creates arrays based on the keywords specified in the script.

The syntax is

ACU /P <file> where file

is the name of the script file. The file parameter can include a drive, directory, filename, and extension. If no drive or directory is specified, the file is placed in the same location as the ACU executable.

Note: The script file syntax allows only one hot spare to be assigned to an array. Therefore, when recording a RAID 10, the ACU can’t map hot spares assigned to the individual mirror sets in the resulting script file. Instead, the ACU creates a single list for all hot spares assigned to

the RAID 10. For more information, see Method Keyword on page 89

.

Appendix D: Using the ACU for DOS ●

86

About Record Mode

Note:

You can also create a script file manually (see page 86 ).

In Record Mode, the ACU writes a RAID controller’s existing array configuration to a specified script file, which lets you create the same configuration by running the ACU in Playback Mode

(/P switch) with the resulting script.

You can only record one RAID controller at a time with Record Mode. Record multiple RAID controllers separately using separate script files.

The syntax is

ACU /R <file>

where file

is the name of the script file. The file parameter can include a drive, directory, filename, and extension, but only the filename and extension are required. If no drive or directory is specified, the file is placed in the same location as the ACU executable.

The ACU supports only a subset of available array types. If it encounters an array it can’t create, a warning displays (or is recorded in the log file, if the /L switch is used); no keywords for that array are recorded in its script file.

When recording an array, the ACU always uses the default Wait setting (equivalent to

Wait=Yes) unless you edit the script file and include Wait=No in the array’s definition block.

For more information, see Wait Keyword on page 90 .

Creating the Script File Manually

Script files contain blocks:

Array definition block keywords (see page 87

)

Optional—ACU error codes (see

The syntax rules are:

page 91 )

Each keyword must start its own line.

Syntax is not case sensitive.

Entering Comments in the Script File

To enter a comment in the script file, start with a pound character (

#

). You can start anywhere

on a line. For a sample script that includes comments, see Sample Scripts on page 92

.

Appendix D: Using the ACU for DOS ●

87

Array Definition Block Keywords

The array definition block always begins with the keyword Array and ends with the keyword

End. The other required array definition keywords are Drives and Type.

Array definition keywords and descriptions are listed in this table.

Keyword

Array

Drives

End

HotspareDrives

InitializeAll

Method

ReadCache

Size

StripeSize

Type

Wait

WriteCache

Required?

Description

Yes

Indicates the start of an array definition block. No default. See page 87

.

Yes Specifies the disk drives used in creating the array. No default. See

page 87

.

Yes

No

Indicates the end of an array definition block. No default. See

page 88

.

Specifies hot spares to assign to the array. No default. See

page 88 .

No

Yes

No

No

No

Yes

No

No

Indicates whether to initialize all the drives connected to the

controller. Default is No. See page 88 .

Indicates the method (Build/Verify, Clear, or Quick Init) to use when creating a redundant array. Default is Build. See

page 89

.

Indicates whether read caching is enabled for this array. Default is

Yes. See page 89 .

Specifies the size of the array. Default is Maximum. See page 89 .

Specifies size of contiguous I/O, in bytes. Default is 256. See

page 89

.

Indicates the type of array to create. No default See page 90 .

Indicates whether the ACU should wait for the new array’s Build/

Verify or Clear to complete before continuing. Default is Yes. See

page 90

.

Indicates whether write caching is enabled for this array. Default is

Yes. See page 90 .

Array Keyword

Array is a required keyword, indicating the start of an array definition block. The syntax is

Array=<label>

, where label

is an optional alphanumeric string.

For example:

Array=MyData

Drives Keyword

Drives is a required keyword, specifying the devices to use in creating the array. There is no default value.

A disk drive is identified by its channel number, ID (target), and LUN, separated by colons; for example,

0:0:0

or

0:1:0

. Separate multiple disk drive identifiers with commas.

Prior to creating any new arrays, the ACU initializes any drives specified by the

Drives keyword. If a disk drive is specified in more than one array definition block in a script, it is initialized only once.

!

Caution: Any disk drive specified within the script file is initialized, which destroys any data on that disk drive.

For example:

Drives=0:0:0

Drives=0:0:0,0:1:0,0:2:0

Appendix D: Using the ACU for DOS ●

88

End Keyword

End is a required keyword, indicating the end of the block.

HotspareDrives Keyword

HotspareDrives is an optional keyword, specifying the hot spares to assign to the array. The

syntax for listing hot spares is the same as the Drives Keyword on page 87

. If HotspareDrives is not specified, no hot spares are assigned to the array.

For example:

HotspareDrives=0:0:0,0:1:0

The same disk drive can be assigned to protect multiple arrays (as a pool spare). Once a pool spare is used by a failed disk drive, however, it is no longer available to protect the other arrays its assigned to.

This keyword does not verify that the available space on the specified hot spares is sufficient to serve as failover for the array.

When assigning hot spares to a multilevel array, HotspareDrives assigns all the hot spares in the list to all arrays within the multilevel array.

InitializeAll Keyword

If you want the ACU to initialize all drives connected to the controller and delete any existing arrays before any new arrays are created, even those that are not specified in any Drives keyword definition, specify InitializeAll=yes. Otherwise, the ACU initializes only those drives specified by the Drives keyword.

!

Caution: Initializing a disk drive automatically deletes any existing arrays with that disk drive as their member.

Possible values:

Yes—Initialize all drives.

No (default)—Do not initialize all drives; only those drives specified with the

Drives keyword are initialized.

For example:

Type=Volume

Type=RAID1

InitializeAll is a global keyword that you need to specify only once.

InitializeAll is always performed prior to array creation regardless of its position in the script.

If both InitializeAll=Yes and InitializeAll=No are specified in the same script file,

InitializeAll=Yes is always the overriding value.

If an array is deleted during a Build/Verify process, the process is automatically terminated.

Appendix D: Using the ACU for DOS ●

89

Method Keyword

Method is an optional keyword, indicating which method to use when creating a redundant

(RAID 1, 5, and 10) array. Possible values:

Build (the default)—Perform a Build/Verify process on the array. Takes longer than Clear, but allows you to begin using the array immediately.

Clear—Clear the array. Faster than a Build/Verify process, but you have to wait for the operation to be completed before you can begin using the array.

Quick Init—Makes the array available immediately, but does not accomplish a Build/

Verify. Parity and mirror information is created as data is written to the disk drive (called full-stripe write mode), which reduces overall array performance. Maximum performance is achieved by starting and completing a Build/Verify.

For example:

Method=Build

ReadCache Keyword

ReadCache indicates whether the array uses read caching.

Possible values:

Yes (default)—Enable read caching.

No—Disable read caching.

For example:

ReadCache=Yes

Size Keyword

The Size keyword specifies the size of the array. Specify Maximum (the default) to create an array using the maximum available space, based on the array type and drives selected.

Otherwise, specify the size as an integer or a decimal number, followed by the unit keyword MB (megabytes), GB (gigabytes), or TB (terabytes).

Note: A unit keyword is required with a numeric size value. If no unit keyword is specified, the

ACU exits with an error.

For example:

Size=2.5GB

Size=300MB

Size=Maximum

StripeSize Keyword

The StripeSize keyword specifies the stripe size (in MB) written to each member of a striped array (RAID 0, RAID 5, or RAID 10).

The possible values for StripeSize are 16, 32, 64, 128, 256, 512 and 1024 KB. Default is 256.

For example:

StripeSize=256

Appendix D: Using the ACU for DOS ●

90

Type Keyword

Type is a required keyword, indicating the array type. There is no default value. The possible values: Volume, RAID0, RAID1, RAID5, RAID10, or RAID50.

Depending on the RAID levels supported by your RAID controller, additional possible values are: RAID1E, RAID5EE, RAID6, RAID60.

Wait Keyword

Wait is an optional keyword that you can use to tell the ACU to allow the ACU to continue while the Build/Verify or Clear completes in the background; specify Wait=No. Otherwise, the

ACU waits by default.

If the host is powered off before the Build/Verify or Clear process completes and is then restarted, the process resumes without any user intervention.

For example:

Wait=Yes

Wait=No

WriteCache Keyword

The WriteCache keyword indicates whether write caching is used for this array if write caching is supported for the system. Possible values are as follows:

Yes (default)—Enable the write cache.

No—Disable the write cache.

Setting an array’s WriteCache keyword to Yes might result in data loss or corruption during a power failure.

For example:

WriteCache=Yes

Channel Definition Block Keywords—SCSI only

The channel definition block is optional. If used, it always begins with the keyword Channel and ends with the keyword End. The channel definition block keywords are listed in this table.

Keyword

Channel

ControllerID

End

Description

Used to identify the channel.

Changes the SCSI ID of the controller.

Indicates the end of a channel definition block.

Channel Keyword

Channel is an optional keyword that begins a channel definition block and specifies the channel number to which the channel keywords apply. Channels are numbered from zero to the maximum number of channels on the controller minus one.

You can include multiple channel definition blocks within a script file, each beginning with a channel keyword and value.

For example:

Channel=0

Appendix D: Using the ACU for DOS ●

91

ControllerID Keyword

ControllerID is an optional keyword to change the SCSI ID of the controller. Normally, the

SCSI controller is assigned SCSI ID 7 on each of its channels. You can specify any ID value between 0 and 7.

!

Caution: Do not change the SCSI ID of the controller unless directed to do so by Adaptec

Technical Support.

For example:

ControllerID=7

End Keyword

End is a required keyword, indicating the end of the block.

ACU Error Codes

When the ACU detects an error, it reports the error and exits immediately. If a log file is specified, the ACU writes the error code to the log file. Otherwise, it displays the error code on the screen.

The possible error messages returned by the ACU are listed in this table.

Code Description

0 ACU ran without changes—ACU exited with no errors (success) and no report is required.

1 No controller found.

2 Syntax or logical error in the script file—The ACU encountered an invalid command or keyword in the specified script file.

3 Unable to open file.

4 Error in the command line parameters—You passed an invalid command-line switch to the

ACU. (See Running the ACU Using Scripts on page 85 for a list of valid command-line switches.)

5 Unable to read system configuration—The ACU was unable to get the configuration information from the specified controller.

6 No drives detected.

7 Specified drive not found in system.

8 Specified array size too small—You specified an array size that is smaller than the minimum size allowed for this array.

9 Specified array size too big—You specified an array size that is larger than the maximum size allowed for this array.

10 Number of drives do not match the array type—The number of drives you selected is invalid for the type of array specified.

11 Unable to initialize drive.

12 Error occurred while creating array.

13 Too many spare drives assigned—You attempted to assign more than the maximum number of hot spares allowed for the specified array.

14 Insufficient memory to run the application.

15 Incorrect controller number.

16 Controller not responding.

17 Build/Verify/Clear failed.

100 You ran ACU and made changes—The ACU exited with no errors (success) and you must restart the computer.

Appendix D: Using the ACU for DOS ●

92

Sample Scripts

This MS-DOS command invokes the ACU and creates arrays on controller 1 based on the array keywords defined in the script file A:\RAID.ACU. It also configures Channel 0 and saves a log of the operation in the log file C:\RAID.LOG:

A:\> ACU /P A:\RAID.ACU /L C:\RAID.LOG /C1

Sample Scripts for SCSI and SAS Controllers

Note: For a sample script for a SATA controller, see

page 93 .

This sample script file is a sample RAID.ACU script as referred to in the ACU command above.

This script creates these arrays—a 500 MB single-disk volume, and a 2-GB two-disk drive

RAID 1 with a hot spare:

# Script to create volume, mirror, and RAID 5 arrays

# Create a 500MB volume labeled ‘MySystem’

Array=MySystem

Type=Volume

Size=500MB

Drives=0:0:0

End

# Create a 2GB mirror labeled ‘MyMirror’

Array=MyMirror

Type=RAID1

Size=2GB

# Use drives 1 and 2

Drives=0:1:0,0:2:0

# Disable write cache

WriteCache=No

# Assign 1 spare drive

HotspareDrives=0:3:0

End

This sample script file creates a maximum-size three-disk-drive RAID 5:

# Create a maximum size RAID 5 labeled ‘MyData’

Array=MyData

Type=RAID5

Size=Maximum

# Use the maximum stripe size

StripeSize=256

# Clear the array (don’t build/verify it)

Method=Clear

# Don’t wait for clear to complete

Wait=No

# Use drives 0, 1, 2

Drives=0:0:0, 0:1:0, 0:2:0

End

Appendix D: Using the ACU for DOS ●

93

Sample Script for SATA Controllers

This is a sample ACU file that will initialize all disk drives connected to the SATA controller and create a RAID 5 array with the disk drives on ports 0, 1, and 2.

Controller= 0,5:7:0

Controller Name=Adaptec Adaptec 2820SA

Subsystem ID=0x2A1

Firmware Version=V5.1-0[6792]

Total Ports=8

Port 0 = 0:0:0 Maxtor 279.479GB 279.395GB

Port 1 = 0:1:0 Maxtor 279.479GB 279.395GB

Port 2 = 0:2:0 Maxtor 279.479GB 279.395GB

Array=MyData2

Type=RAID5

Size=Maximum

InitializeAll=Yes

Method=Build/Verify

Wait=No

Drives=0:0:0, 0:1:0, 0:2:0

End

Using the Adaptec Flash Utility

E

In this appendix...

System Requirements ............................................................................................................. 95

Before You Begin .................................................................................................................... 95

Running the Menu-based AFU.............................................................................................. 96

Running the AFU from the Command Line......................................................................... 97

Updating the Flash Using the AFU Command Line .......................................................... 100

This chapter describes how to use the Adaptec Flash Utility (AFU), a text-based DOS utility that you can use to update, save, or verify the RAID controller’s firmware BIOS and

Non-Volatile Random Access Memory (NVRAM).

!

Caution: Although the AFU contains safeguards to prevent you from accidentally damaging your RAID controller’s flash contents, it is still important to use the AFU carefully and correctly to avoid rendering your RAID controller inoperable.

Adaptec recommends that only advanced users familiar with working in DOS use the AFU.

For more information, see

Managing Your Storage Space on page 52

.

Appendix E: Using the Adaptec Flash Utility ●

95

System Requirements

● MS–DOS version 5.0 or later.

Note: You can’t run the AFU from a DOS command prompt window under any version of

Windows.

● At least 8 MB of extended memory.

Compatibility Notes

● Supports HIMEM.SYS; compatible with other DOS drivers running under HIMEM.SYS

(for example, SMARTDRV.SYS and SETVER.SYS).

Does not support DOS extenders installed in memory, such as EMM386.SYS and

DOS4GW.

Before You Begin

Before you begin:

1

2

Obtain the firmware (see the following section).

Create a firmware kit on floppy disks (see page 96

).

There are two ways to run the AFU:

● Using the AFU menus (see

page 96 )

From the command line (see page 97

)

Obtaining the Firmware

To obtain RAID controller firmware, go to:

The RAID Installation CD—Includes the AFU executable (AFU.exe) and a separate flash image. The flash image may comprise multiple User Flash Image (UFI) files.

The Adaptec Web site—Download a new firmware file to get the most recent version of

AFU.

See www.adaptec.com

for more information.

Appendix E: Using the Adaptec Flash Utility ●

96

Creating the Firmware Floppy Disks

Note: You will need at least two bootable MS-DOS floppy disks to complete this task.

You can’t create a bootable floppy disk using Windows 2000.

To create the firmware floppy disks:

1 Create a bootable MS–DOS floppy disk and copy these files to it:

AFU.exe

AAxxx01.ufi

2

3 where xxx is the model number of your controller.

Create additional bootable MS–DOS floppy disks and copy each additional AAxxx0x.ufi file to a separate floppy disk. (Some RAID controllers have two UFI files; some have four.

Each goes onto its own floppy disk.)

To use a menu-based AFU, see the following section.

To run the AFU from the command line, see page 97

.

Running the Menu-based AFU

Note: You can also run the AFU from the command line (see

page 97 ).

To run the menu-based AFU:

1 Shut down your operating system and reboot to DOS from a bootable MS-DOS floppy disk or from a DOS partition on a bootable drive. (You can use a disk drive connected to the controller you are updating.)

2

3

4

5

6

At the DOS command prompt, type

AFU

with no arguments.

The AFU’s main menu is displayed.

Select Select Controllers, then select the Adaptec RAID controller(s) to be flashed.

To update multiple RAID controllers in the same system, update the boot controller’s flash first, restart the computer, then update the flash for the remaining controllers.

Select Select an Operation.

Choose the operation you want, then follow the on-screen instructions to complete the task:

Update—Updates all the flash components on a RAID controller with the flash image data from the UFI file.

Save—Reads the contents of a RAID controller’s flash components and saves the data to a UFI file, which you can use to restore a RAID controller’s flash if required.

Verify—Reads the contents of a RAID controller’s flash components and compares it to the contents of the specified UFI file.

Version—Displays version information about a RAID controller’s flash components.

List—Lists all supported RAID controllers detected on your system.

Complete the flash operation and restart your computer before trying to use the RAID controller again. (You can not use your RAID controller while you are updating its flash.)

Appendix E: Using the Adaptec Flash Utility ●

97

Running the AFU from the Command Line

Note: You can also run a menu-based AFU (see

page 96

).

To run the AFU from the command line:

1 Power off your computer, insert the first AFU floppy disk, then power on your computer.

2

If your computer isn’t set up to boot from the bootable floppy disk, enter the system setup utility to change the setting.

At the DOS command, type AFU followed by a command (see

page 97 ) and any switches

you want.

Note: To find a controller number, type AFU LIST, then press Enter.

The AFU processes the command, prompts you to insert additional floppy disks as needed, exits, and reports either success or an error message code.

To update a RAID controller’s flash using the command line, see

page 100

.

AFU Commands

This section lists the available AFU commands.

List

Displays the AFU-supported RAID controllers installed on your computer. Also displays the ID numbers assigned to each controller.

You don’t have to restart the computer after completing this command.

This example shows a typical system response to a LIST command:

A:\> AFU LIST

Adaptec Flash Utility V4.0-0 B5749

(c)Adaptec Inc. 1999–2005. All Rights Reserved.

Controllers Detected and Recognized:

Controller #0 (03:05:00) Adaptec Adaptec 2230SLP

Save

Saves the contents of a RAID controller’s flash in a UFI file. The name of the UFI file is based on the controller type and can’t be changed.

You must restart the computer following a SAVE command.

The command syntax for the SAVE command is

AFU SAVE [/C<Controller ID>] [/D <UFI File Path>]

Appendix E: Using the Adaptec Flash Utility ●

98

These switches are available:

/C <Controller ID>—One or more RAID controller IDs representing the set of RAID controllers on which to perform the specified command. The default is 0; if the computer has multiple RAID controllers, the AFU defaults to controller 0 unless you specify otherwise.

For example:

To specify a single RAID controller ID:

/C 0

To specify multiple IDs separated by commas:

/C 0,2

To indicate all RAID controllers:

ALL

If you are using multiple RAID controllers, you must specify the controller you want by using the /C switch; otherwise, the AFU displays an error message and exits.

/D <UFI File Path>—Specifies the path where the UFI files are located. If you do not specify the /D switch, the AFU looks for (or creates) its UFI files in the default location.

You cannot specify the name of a UFI file, only its path. UFI filenames are predefined, based on the RAID controller type.

In this example, the AFU saves flash contents from RAID controller 0 to a UFI file in the current default drive and directory:

A:\> AFU SAVE /C 0

In this example, the AFU saves flash contents from Controller 1 to a UFI file in

C:\UFI_FILES:

A:\> AFU SAVE /C 1 /D C:\UFI_FILES

Update

Updates the flash components of one or more RAID controllers on your computer from the flash image data in a UFI file. You must restart the computer following an update command.

The command syntax for the update command is:

AFU UPDATE [/C<Controller ID>] [/D <UFI File Path>]

You can also use the /C and /D switches (see Save on page 97

).

This example shows a typical system response after an update.

A:\> AFU UPDATE /C 0

Adaptec Flash Utility V4.0-0 B5749

(c)Adaptec Inc. 1999–2005. All Rights Reserved.

Updating Controller 0 (Adaptec 2820)

Reading flash image file (Build 5749)

AFU is about to update firmware on controllers Adaptec Adaptec 2230SLP

***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE***

This might take a few minutes.

Writing Adaptec Adaptec 2230SLP (4MB) Flash Image to controller 0...OK.

Verifying...OK

Please restart the computer to allow firmware changes to take effect.

Appendix E: Using the Adaptec Flash Utility ●

99

Verify

Compares the contents of each of the flash components on a RAID controller to the corresponding image in a UFI file, and indicates whether they match. After using the verify command, you must restart the computer.

The command syntax for the VERIFY command is as follows:

AFU VERIFY [/C<Controller ID>] [/D <UFI File Path>]

You can also use the /C and /D switches. See Save on page 97

for more information.

This example shows a typical system response after a verify command.

A:\> AFU VERIFY /C 0

Adaptec Flash Utility V4.0-0 B5749

(c)Adaptec Inc. 1999–2005. All Rights Reserved.

Reading flash image file (Build 5748)

Controller #0: Adaptec Adaptec 2820SA

ROM: Checksum: 797B [VALID] (Build 5748)

File: Checksum: 797B [VALID] (Build 5748)

Image Compares Correctly

Version

Displays version information about the flash components on a RAID controller. After using the version command, restart your computer.

The command syntax for the version command is:

AFU VERSION [/C<Controller ID>]

You can also use the /C switch. See

Save on page 97 for more information.

This example displays version information about all supported RAID controllers.

A:\> AFU VERSION /C 0

Adaptec Flash Utility V4.0-0 B5749

(c)Adaptec Inc. 1999–2005. All Rights Reserved.

Version Information for Controller #0 (Adaptec Adaptec 2820SA)

ROM: Build 5748 [VALID] Fri Sep 27 13:28:40 EDT 2005

A:\> AFU VERSION /C ALL

Help

Displays a summary of AFU functions and command switches. For example:

A:\> AFU HELP

A:\> AFU /?

Appendix E: Using the Adaptec Flash Utility ●

100

Updating the Flash Using the AFU Command Line

1 Create the firmware floppy disks (see

page 96

).

2

3

4

5

Power off your computer, insert the first AFU floppy disk, then power on your computer.

If your computer isn’t set up to boot from the bootable floppy disk, enter the system setup utility to change the setting.

At the DOS command, if you have multiple controllers and you don’t know the number of the controller you want to update, type

AFU LIST

, then press Enter. Otherwise, skip to the next step.

At the DOS command, type AFU followed by a command (see

page 97 ) and any switches

you want.

Update the flash using the instructions suitable for your requirements:

To update a single RAID controller:

AFU UPDATE /C <cont_number>

Where <cont_number> is the number of the RAID controller whose firmware you are updating. For example, to upgrade Controller 0, type AFU UPDATE /C 0

To update multiple RAID controllers:

AFU UPDATE /C <cont_number_a>,<cont_number_b>

Where <controller_number_a> and <controller_number_b> are the numbers of the

Adaptec RAID controllers whose firmware you are updating. For example, to upgrade controllers 0, 2, and 3, type

AFU UPDATE /C 0, 2, 3

To update all RAID controllers simultaneously:

AFU UPDATE /C all

Note: The UFI file identifies the RAID controllers, so you don’t have to worry about flashing the wrong controller.

6

7

8

When prompted, insert the first firmware disk into your floppy disk drive.

The AFU reads the first disk.

When prompted, remove the first firmware disk and insert the second firmware disk into your floppy disk drive.

Repeat

Step 7 as required until the flash update is complete.

Safety Information

F

To ensure your personal safety and the safety of your equipment:

● Keep your work area and the computer clean and clear of debris.

● Before opening the system cabinet, unplug the power cord.

Electrostatic Discharge (ESD)

!

Caution: ESD can damage electronic components when they are improperly handled, and can result in total or intermittent failures. Always follow ESD-prevention procedures when removing and replacing components.

To prevent ESD damage:

● Use an ESD wrist or ankle strap and ensure that it makes skin contact. Connect the equipment end of the strap to an unpainted metal surface on the chassis.

If a wrist strap is not available, ground yourself by touching the metal chassis before handling the controller or any other part of the computer.

Avoid touching the controller against your clothing. The wrist strap protects components from ESD on the body only.

Handle the controller by its bracket or edges only. Avoid touching the printed circuit board or the connectors.

Put the controller down only on an antistatic surface such as the bag supplied in your kit.

If you are returning the controller to Adaptec, put it back in its antistatic bag immediately.

Technical Specifications

G

In this appendix...

Environmental Specifications.............................................................................................. 103

DC Power Requirements...................................................................................................... 103

Current Requirements.......................................................................................................... 103

Appendix G: Technical Specifications ●

103

Environmental Specifications

Ambient temperature without battery backup module

Relative humidity

Altitude

0 °C to 50 ° C

10% to 90% , noncondensing

Up to 3,000 meters

Note: Forced airflow is recommended, but not required.

DC Power Requirements

Ripple and noise

DC Voltage

50 mV peak-to-peak (max)

5 V ± 5%, 3.3 V ± 10%

Current Requirements

Adaptec Model

Adaptec 4000SAS

Adaptec 4800SAS

Adaptec 4805SAS

Adaptec 2420SA

Adaptec 2820SA

Adaptec 2130SLP

Adaptec 2230SLP

Maximum Current (A)

1.5 A @ 3.3 VDC; 0.75 A @ 5.0 VDC

1.4 A @ 3.3 VDC; 2.4 A @ 5.0 VDC

1.5 A @ 3.3 VDC; 1.3 A @ 12.0 VDC

0.36 A @ 3.3 VDC; 2.4 A @ 5 VDC

0.37 A @ 3.3 VDC; 2.4 A @ 5.0 VDC

2.5 A @3.3VDC; 2 A @ 5.0 VDC

2.5 A @3.3VDC; 2 A @ 5.0 VDC

A

ACU

arrays

37

creating arrays

37 ,

76

creating bootable arrays

77

initializing disk drives

77

managing arrays

77

rescanning disk drives

77

secure erasing disk drives

78

stopping a secure erase

78

ACU for DOS

83 to

93

array definition block keywords

87

creating a floppy disk

84

menus

84

playback mode

85

record mode

86

sample scripts

92

script file syntax

86

scripts

85

switches

85

Adaptec customer support

3

Adaptec Flash Utility. See AFU

Adaptec RAID Controller Configuration utility. See

ARCCONF

Adaptec RAID Controller utility

54 ,

75

to

82

Adaptec Storage Manager

53

creating arrays

39

installing

53

adapters. See controllers

advanced data protection

17

AFU

54 ,

94

to

100

Alarm Control setting

79

ARCCONF

53

Array Background Consistency Check setting

79

Array Configuration Utility. See ACU

array definition block

End keyword

88

HotspareDrives keyword

88

array migration

17

Array-based BBS Support setting

79

arrays creating (ACU)

37 ,

76

creating (Adaptec Storage Manager)

39

creating bootable arrays

77

making an array bootable

40

managing with ACU

77

non-RAID

67

RAID 1

68

RAID 10

69

RAID 1E

68

RAID 5

70

RAID 50

72

RAID 5EE

71

RAID 6

73

RAID 60

73

arrays (bootable)

36

audible alarm

56

automatic failover

17

Automatic Failover setting

79

B backplane connections

34

, 64

battery backup module

18

BBS Support setting

79

BBU

18

boards. See controllers

boot controller

37

Index

Index ●

105 bootable arrays

40

creating

36 ,

77

C cables

29

cards. See controllers

CD-ROM Boot Support setting

79

command line interface (flash utility)

97

command line utility

53

contents of controller kit

14

Controller SCSI Channel ID setting

81

Controller SCSI Channel Termination setting

81

controllers

Alarm Control setting

79

Array Background Consistency Check setting

79

Array-based BBS Support setting

79

array-level features

17

Automatic Failover setting

79

BBS Support setting

79

cables

29

CD-ROM Boot Support setting

79

connecting external devices

35

data protection

17

descriptions

16 to

25

disk drives

28

Drive’s Write Cache setting

79

enhanced features

18

event log

82

figures

16 to

25

firmware

95

flashing

58

installation options

30

installing

32

keyed features

18

modifying general settings

79

modifying settings with -Select utilities

78

Physical Drives Display During POST setting

79

RAID levels

27

Removable Media Devices Boot Support setting

79

resetting

58

Runtime BIOS setting

79

setting boot controller

37

specifications

102

standard features

troubleshooting

56

updating firmware

95

upgrading firmware

18

copyback

17

CRC Checking setting

80

customer support

3

D direct-attach connections

33

, 63

disk drives

28

cables

29

connecting to SAS controllers

33

connecting to SATA controllers

34

connecting to SCSI controllers

35

external

35

failure recovery multiple arrays

57

multiple disk drives

58

RAID 0 arrays

57

with hot spare

57

without hot spare

57

formatting

82

HVD

28

initializing

77

LVD

28

recovering from failure

56

rescanning

77

SAS identifiers

63

SE

28

secure erasing

78

stopping a secure erase

78

verifying

82

drive requirements

28

Drive’s Write Cache setting

79

driver and operating system installation

41

to

46

driver disk

42

driver installation

47

to

51

drivers installing on FreeBSD

51

installing on Linux

49

installing on NetWare

49

installing on OpenServer

50

installing on Solaris

51

installing on UnixWare

50

installing on Windows

49

installing with FreeBSD

46

installing with Linux

43

,

44

installing with NetWare

44

installing with OpenServer

45

installing with UnixWare

45

installing with Windows

43

E electrostatic discharge

101

Enable Disconnection setting

81

end devices

60

End property

88

Index ●

106 enhanced features

18

event log

82

expander connections

64

expander devices

60

external devices

35

F failed disk drives

56

multiple arrays

57

multiple disk drives

58

RAID 0 arrays

57

without hot spare

57

feature keys

18

firmware

95

creating floppy disks

96

firmware upgrades

18

flashing controllers

58

floppy disks for firmware update

96

formatting disk drives

82

FreeBSD driver installation

51

OS installation

46

H

hard disk, hard disk drive, hard drive. See disk drive

hot spares

17

HotspareDrives keyword array definition block

88

I initializing disk drives

77

Initiate Wide Negotiation setting

81

installation controllers

32

creating a driver disk

42

disk drives (SAS)

33

disk drives (SATA)

34

disk drives (SCSI)

35

driver

47

to 51

driver and FreeBSD

46

driver and Linux

43 ,

44

driver and NetWare

44

driver and OpenServer

45

driver and operating system

41

to

46

driver and UnixWare

45

driver and Windows

43

existing operating system

30

external devices

35

installation options

30

SAS backplane

34

installation, continued

SAS direct-attach

33

with operating system

30

K keyed features

18

kit contents

14

L links (SAS)

61

Linux driver installation

49

OS installation

44

Linux installation

43

locked features

18

M

Managing

77

Maximum Transfer Rate setting

81

mirroring

27

N

NCQ

17

NetWare driver installation

49

OS installation

44

non-RAID arrays

67

O online expansion

17

OpenServer driver installation

50

OS installation

45

operating system installation

41

to

46

operating systems

14

P

Packetized setting

81

parity

27

Phy Rate setting

80

phys

61

Physical Drives Display During POST setting

79

playback mode

85

Q

QAS setting

81

R

RAID

RAID 0

67

RAID 1

68

RAID 10

69

RAID 1E

68

RAID 5

70

RAID 50

72

RAID 5EE

71

RAID 6

73

RAID 60

73

RAID 1E

17

RAID 5EE

17

RAID 6

17

RAID 60

17

RAID controllers. See controllers

RAID levels

27

record mode

86

recovering from disk drive failure

56

Red Hat driver installation

49

OS installation

43

Redundant Array of Independent Disks. See RAID

Removable Media Devices Boot Support setting

79

replacing failed disk drives

56

requirements

14

drive

28

rescanning disk drives

77

resetting controllers

58

Runtime BIOS setting

79

S safety information

101

SAS

4-wide ports

62

backplane connections

34

, 64

cables

29 ,

63

comparison to parallel SCSI

65

connectors

62

description

60

direct-attach connections

33 ,

63

disk drive identifiers

63

disk drives

28

edge expanders

64

end devices

60

expander connections

64

expander devices

60

fanout expanders

64

link speed

60

links

61

Index ●

107

SAS, continued narrow connectors

62

narrow ports

62

phys

61

ports

61

,

62

SAS address

62

SAS cards

60

SAS devices

60

SAS domain

64

terminology

60

transceivers

61

wide connectors

62

wide ports

62

SAS Address setting

80

SAS controllers cables

29

connecting disk drives

33

CRC Checking setting

80

disk drives

28

modifying with -Select utilities

80

Phy Rate setting

80

SAS Address setting

80

SAS devices

60

SATA

cables

29

disk drives

28

SATA controllers cables

29

connecting disk drives

34

disk drives

28

modifying with -Select utilities

80

Write Cache setting

80

SATASelect

78

scripts in ACU for DOS

92

SCSI

cables

30

comparison to SAS

65

disk drives

28

SCSI controllers cables

30

connecting disk drives

35

Controller SCSI Channel ID setting

81

Controller SCSI Channel Termination setting

81

disk drives

28

Enable Disconnection setting

81

Initiate Wide Negotiation setting

81

Maximum Transfer Rate setting

81

modifying with -Select utilities

81

Packetized setting

81

QAS setting

81

SCSI Parity Checking setting

81

SCSI Parity Checking setting

81

SCSISelect

78

secure erasing disk drives

78

stopping a secure erase

78

-Select utilities

78

applying changes

78

exiting

78

modifying controller settings

79

opening

78

Serial ATA. See SATA

Serial Attached SCSI. See SAS

SerialSelect

78

Small Computer System Interface. See SCSI

snapshot

18

software

53

Solaris driver installation

51

specifications

102

storage management

Adaptec RAID Controller utility

54

Adaptec Storage Manager

53

AFU

54

ARCCONF

53

storage space

12

support, customer

3

SuSE driver installation

49

SuSE installation

44

switches in ACU for DOS

85

system requirements

14

T technical specifications

102

technical support

3

Technical Support Identification (TSID) number

3

terminology

12

Adaptec Storage Manager

12

SAS

60

Index ●

108 tools

Adaptec RAID Controller utility

54

Adaptec Storage Manager

53

AFU

54

ARCCONF

53

troubleshooting tips

55

TSID Number

See Technical Support Identification Number

U

UnixWare driver installation

50

OS installation

45

updating firmware

95

upgrading firmware

18

utilities

Adaptec RAID Controller utility

54

AFU

54

ARCCONF

53

V verifying disk drives

82

W

Windows driver installation

49

OS installation

43

Write Cache setting

80

Adaptec, Inc.

691 South Milpitas Boulevard

Milpitas, CA 95035 USA

©2005-06 Adaptec, Inc.

All rights reserved. Adaptec and the Adaptec logo are trademarks of Adaptec, Inc. which may be registered in some jurisdictions.

Part Number: CDP-00062-01-A, Rev. B

LB 03/06

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents