BIRADIAL ELLIPTICAL
The Shure M94 LT Cartridge, mounts directly t o Technics Linear Tracklng Turntables such as Models SL5, SL7, SLlO and SL15 This cartridge brings outstanding
trackability and transparent frequency response t o the Technics Linear Tracking
Turntables
TRACKING FORCE
The M94 I T is designed t o operate at a tracklng force of 1.25 grams optimum. D o
not use tracking forces heavler than 1 5 grams Consult the turntable manufacturer if you have any doubts about whether its tracking force is appropriate.
MOUNTING, MONTAGE, MONTAJE
SPECIFICATIONS
Frequency Response: 20 t o 20,000 H z
Typical Trackability (at 1.25 grams tracklng force, in cm/sec peak velocity):
10,000 Hz - 16 cmlsec
400 Hz - 26 crnlsec
1.000 H z - 30 cmlsec
Output Voltage (at 1,000 Hz, 5 cmlsec peak velocity): 4 5 mV per channel
Channel Balance: Within 2 dB
Channel Separation (minimum): 25 dB at 1,000 H z
Optimum Load: 47,000 ohms resistance in parallel with 200 t o 300 picofarads
capacitance per channel Load resistance can be up to 70.000 ohms w ~ t halmost
no audible change in frequency response Total capacitance includes both the
tone arm wiring and amplifier input circuit
Inductance: 700 milllhenrles
DC Resistance: 1550 ohms
Net weight: 6 grams
Replacement Stylus: N94LT with 10 x 18p (0004 x ,0007 in.), biradial elliptical
diamond tip, Dark Blue grlp
al m
2
FIGURE 1
3
STYLUS CLEANING
Use a soft brush with an alcohol-distilled water solution or Shure Stylus Cleaning Solution (See your
dealer and ask for the Shure SK-I, Stylus Clean~ngKit )
Brush only from back t o front as shown in Figure 2.
Other commerc~alcleaning solutions may cause stylus
damage
STYLUS REPLACEMENT
Place the Techn~csL~nearTrack~ngarm In a conve
n ~ e np
t o s ~ t ~ oasn follows
1 W ~ t hthe Ild closed use the"manual"mode t o move
the arm to approx~matelythe center of ~ t stravel
2 Make certaln the cartr~dge1s cued "up" (ra~sedoff
the record), and press the O f f O n s w ~ t c h" O f f "
3 Ra~sethe 11d
Replace the stylus as shown In F~gure3 Always hold
the stylus only by the plast~cgrlp, take care not to
touch or damage the thank or d ~ a m o n dt ~ p
STYLUS CLEANING
FIGURE 2
I 1
TI?!
STYLUS REPLACEMENT
FIGURE 3
PREAMPLIFIER SETTING
The M94 LT is a moving magnet cartridge If your Technics Linear Tracking Turntable has a preamplifier selector swltch, be sure t o set the switch t o the moving
magnet position (MM)
SPECIAL NOTE
As the only source of contact between the record groove and the balance of your
high fidelity system, the stylus in your cartridge plays a crltlcal role in the ultimate
quality of sound reproduction. Additionally, because records can be irreparably
damaged by a worn stylus, it is essential to ensure that your Shure stylus is in peak
condition in order t o preserve your records in "mlnt" condition. Your cartr~dgecan
perform at original operating specifications for many years with these simple
maintenance steps:
1. Follow the stylus cleaning instructions given on page 4
2. See your Shure dealer at least once a year for a checkup of your cartridge's
stylus. He'll clean it and inspect i t for wear.
3. When it becomes necessary t o replace your stylus, insist on a genulne Shure
replacement Extensive testing of imitations of Shure styli revealed numerous
grave flaws To be c e r t a ~ nthat your replacement stylus meets orlglnal
specifications, look for the name SHURE@on the stylus grip and the words
"This Stereo DYNETIC@stylus is precision manufactured by Shure Brothers
Inc." on the stvlus box.
R E C O M M A N D A T I O N S POUR LE NETTOYAGE DE LA POINTE: Utilisez une
brosse douce, humectee d'alcool pur ou dilue. Les liquides de nettoyage vendus
dans le commerce peuvent endommager ou corroder la pointe. Brossez toujours
d'arriere en avant.
REMPLACEMENT D U D I A M A N T : Placer le bras de la. platlne Technics dans la
position adequate. Operer comme suit:
1. Le capot etant ferme, utiliser le mode "manuel" pour placer le bras approximativement a mi-course.
2. S'assurer que le bras est en position "up"(cellule non en contact avec le d~sque),
et mettre le contacteur d'alimentation de la platine sur "off."
3. Soulever le capot.
Remplacer le diamant comme la figure. Tenir ledlamant par le plastique, prendre
garde a ne pas toucher ou endommager le diamant ou le tube porte pointe
REGLAGE D U PREAMPLI: La M94 LT est une cellule a aimant mobile Si votre
platine Technics a un preampli cellule incorpore, assurez vous que le selecteurest
sur la position MM (moving magnet).
FORCE D'APPUI: La M94 LT est concu pour fonctionner a une force d'appui optimale de 1.25 g. Ne pas utiliser de pression plus importante que 1,5 g. En cas de
doute, contacter le fabricant de le platine afin de s'assurer que la force d'appui est
correcte
FULL ONE-YEAR W A R R A N T Y : Shure Brothers lncorporated ("Shure"). 222 Hartrey Avenue, Evanston, Illinois 60204, warrants to the owner of this product that it
will be free, In normal use, of any defects in workmanship and materials for a
period of one year from date of purchase You should r e t a ~ nproof of date of purchase Shure is not llable for any consequential damages If this Shure product has
any defects as described above, carefully repack the unit and return it prepaid to:
Shure Brothers lncorporated
Attention: Servlce Department
1501 West Shure Drive
Arlington Heights, Illinois 60004
If you are not In the United States, return the unlt to your dealer or Authorized
Serv~ceCenter for repair The untt will be repaired or replaced and returned t o you
promptly, and if it cannot be repaired or replaced, you may elect to receive a refund. This warranty does not include stylus wear
PATENT NOTICE: All Shure Styli and Cartridges are manufactured under one or
more of the f o l l o w ~ n gU S Patents. 3.055.988; 3,077,521, 3,077,522, 3,463,889;
4,270,758; 4,194,744, 4,275,888. D l 93,854; D l 93,934, D201.803, D235,070,
D235.351. D235.352. D245.022, D245.433, D252.628, 0254,004, D257,676,
D255.898, D258.586; other patents pending
Copyright 1982. Shure Brothers Inc
27A1732 (HA)
Printed ~nU 5 A
9

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Languages