Dynacord | DCS 407R

DCS 407R

www.dynacord.com

▪ 4 low frequency relays, 2 switch contacts each.

▪ Gold-plated double contacts for high level of contact reliability.

▪ Pluggable connection terminals with screwed flange for all contacts and coils.

▪ 4 relay control LEDs.

No.

1

2

The module is fitted on the back of the DCS 400 rack plug-in board. The module is used to switch audio signals (line levels) or for control purposes regardless of the DCS 400 system.

Additional properties:

• Configure the audio distributor by separating the wire jumpers.

• A monitor bus can be connected.

Parts included

Component

DCS 407R

Plug, 15-pin (Phoenix MC 1.5/15-STF-3.81 - 1827839)

Technical specifications

24 V DC, -10%/+30% Operating voltage

Operating current

• Standby

• Idle/Announcement/Alert

Electromagnetical environment

Operating temperature

24 V, 5.5 mA, 0.14 W

24 V, 42 mA, 1.01 W

E1, E2, E3

-5 °C to 45 °C

Product dimensions (Width by

Height by Depth)

Net weight

Relay contacts

• Contacts

• Contact material

• Contact load (real)

• Contact current max.

37.5 by 80.6 by 245 mm

163 g

2 SPDT

AgPd + 10μ Au

1 A / 24 V DC

0.5 A / 120 V DC

2 A

2 | DCS 407R

DATA5

DATA5_A

DATA_SEL

DATA4_SEL_A

EN1

EN1_A

EN2

EN2_A

EN3

EN3_A

EN4

EN4_A

EN5

EN5_A

EN6

EN6_A

EN7

EN7_A

EN8

EN8_A

MON+

MON-

CLK1

CLK1_A

CLK2

CLK2_A

CLK3

CLK3_A

RES

RES_A

*RES

*RES_A

DATA1

DATA1_A

DATA2

DATA2_A

DATA3

DATA3_A

DATA4_A

+24V

GND

Block diagram

Installation/configuration notes

Installation information

On the DCS 400 rack plug-in board, slots 1–10 must be occupied in ascending sequence (left to right) without any gaps. Different module types can otherwise be arranged in any sequence.

Exception: Slot 1 (far left) must always be occupied with a DCS 801R control module or DCS 405R extension module.

When assembling the device and installing the connections, please comply with the standards VDE

0100 and EN 60065.

Connector

The scope of delivery for the device includes two 15pin connectors. Conductor cross-sections of 0.14 mm²

(AWG26) to 1.5 mm² (AWG16) can be used.

Recommended connecting cable: flexible CU strand,

LiY, 0.75 mm².

Certifications and approvals

Status as of November 2012:

• EN 50130-4

• EN 54-16

• EN 55103-1

• EN 55103-2

A13

A14

B28

B29

A15

B30

A10

A12

B27

B25

A11

B26

A4

A6

B21

B19

A5

B20

A7

A9

B24

B22

A8

B23

A1

A3

B18

B16

A2

B17

Ordering information

DCS 407R

Order number F01U121782

3 | DCS 407R

Represented by:

Germany:

EVI Audio GmbH

Sachsenring 60

94315 Straubing

Germany www.dynacord.com

© Bosch Security Systems 2013 | Data subject to change without notice