Models TVB-2 Instructions Sheet

Add to my manuals
7 Pages

advertisement

Models TVB-2 Instructions Sheet | Manualzz

Models

TVB-2

Item 39372 Ver 1.03

Instructions Sheet

TVB-2

Test Verification Box

© Associated Research, Inc. 2013

13860 West Laurel Drive

Lake Forest, Illinois, 60045

U.S.A.

Printed January 10, 2014

2

DECLARATION OF CONFORMITY

Manufacturer: Associated Research, Inc.

Address:

Product Name:

13860 W. Laurel Dr.

Lake Forest, IL 60045 USA

Verification Load Box

Model Number: TVB-2

Conforms to the following Standards:

Safety: IEC 61010-1:2010

EN 61010-1:2010

UL 61010-1:2012

CAN/CSA-22.2 NO. 61010-1-12

EMC: EN 61326-1:2006, EN 61326-2-2:2006

(EN 61000-4-2:2008)

Supplementary Information

The product herewith complies with the requirements of the Low

Voltage Directive 2006/95/EC and the EMC Directive 2004/108/EC.

The technical file and other documentation are on file with

Associated Research, Inc.

______________________________

Joseph Guerriero

Vice President / General Manager

Associated Research, Inc.

Lake Forest, Illinois USA

June, 2013

Instruments for Electrical

Safety Testing . . . Since

1936

TVB-2 Technical Specifications

MODEL

Components

120kΩ

1MΩ

0.5Ω

49mΩ

100mΩ

GENERAL

Test Points

PASS

ACW/DCW 2MΩ / 6W

TVB-2

Resistor Specification

2.5KVac / 50W / 1% +/- 50ppm

3KVdc / 3W / 1% +/- 50ppm

350Vdc / 2W / 5% +/- 300ppm

100Vdc / 50W / 1% +/- 50ppm

100Vdc / 25W / 1% +/- 100ppm

Test Condition

1. ACW: 1240V, 10mA or DCW: 2121V, 5000uA

2. Maximum Voltage 2500V

3. Test duty cycle, OFF time = ON time x 2

4. Maximum ON time limit 30 seconds

5. Recommended 2s ramp time

Specification

2%

FAIL

ACW/DCW 120kΩ / 50W

1. ACW: 1240V, 10mA or DCW: 2121V, 5000uA

2. Maximum Voltage 2300V

3. Test duty cycle, OFF time = ON time x 8

4. Maximum ON time limit 5 seconds

5. Recommended 2s ramp time

2%

PASS

IR 4MΩ / 12W

FAIL

IR 1MΩ / 3W

PASS

GC 0.5Ω / 2W

FAIL

GC 2Ω / 8W

1. IR: 500V, 2MΩ

2. Maximum Voltage: 2500V

1. IR: 500V, 2MΩ

2. Maximum Voltage 1000V

1. GC: 0.1A, 1Ω

2.Maximum Current 1A

2%

2%

5%

5%

PASS

GB 50mΩ / 50W

FAIL

GB 200mΩ / 50W

Environment

1. GB: ≤ 30A, 100mΩ

2. Maximum Current 30A

3. Test duty cycle, OFF time = ON time x 6

4. Maximum ON time limit 5 seconds

5. Maximum resistance range at 30A is 200mΩ 1

1. Test Current 15A

2. Test duty cycle, OFF time=ON time x 6

3. Maximum ON time limit 10 seconds

4. Maximum resistance range at 30A is 200mΩ 1

32° F - 104° F (0° - 40° C)

5%

3%

Dimensions 7.3" (W) x 5.75" (L) x 2.95" (H) , 186mm x 146mm x 75 mm

Weight 1.55 lbs

1 Note:if the resistance is greater than 200mΩ you must reduce the test current to 10A in order to display the actual resistance reading.

TVB-2 Instructions V1.03 Item #39372

Instruments for Electrical

Safety Testing . . . Since

1936

Note: si la résistance est supérieure à 200mΩ vous devez réduire le courant de test par 10A afin d'afficher la valeur de la résistance réelle.

Symbols Explanation:

Please refer to the instruction manual for specific warning or caution information to avoid personal injury or damage to the product.

S'il vous plaît se référer au manuel d'instructions de mise en garde ou information sur la prudence pour éviter des blessures ou des dommages au produit

To indicate hazardous voltages may be present.

Avertissement des tensions dangereuses qui peuvent être présentes

General Information

The TVB-2 is a go/no-go load box for verifying that the failure detectors of your

Associated Research electrical safety testing instrument are functioning properly.

Use the TVB-2 daily before you begin performing Hipot, Insulation Resistance,

Ground Bond and Ground Continuity tests. The TVB-2 is not intended to comply with any specific safety agency standard.

Note: the trip setting may vary up to 10% of the set value based on the combined tolerances of the instrument and the components used in the TVB-2.

Using the TVB-2

The TVB-2 load box consists of resistors of varying types that induce a PASS or

FAIL condition depending on the test parameters that are set in your electrical safety tester. The 8 banana jacks located on the top of the box can be used to apply the corresponding load to the output of your tester. Each banana jack should be used for a particular type of test, which is outlined on the layout of the load box.

To setup a test, connect the high voltage or high current test lead of your electrical safety tester to one of the GC, GB, ACW/DCW, or IR test points.

Connect the return lead to the Return point. Ensure that the settings on your electrical safety tester are less than or equal to the maximum recommended voltage, current and duty cycle settings of the TVB-2. When all connections have been made, press the TEST button to begin the test. With the correct settings entered into the electrical safety tester, connecting the output leads to a PASS

TVB-2 Instructions V1.03 Item #39372

Instruments for Electrical

Safety Testing . . . Since

1936 terminal should result in a PASS. Connecting the output leads to a FAIL terminal should result in a FAIL.

Note: pay close attention to the maximum voltage and duty cycle limitations of each resistor. Applying voltages that are higher than the recommended maximum setting or duty cycles greater than indicated can cause damage to the TVB-2.

Note: attention à la tension maximale et les limites du cycle de travail de chaque résistance. L'application de tensions plus élevées que le réglage maximum recommandé ou cycles de travail supérieures à celles indiquées peut causer des dommages à la

TVB-2

Recommended Test Parameter Conditions

The follwoing table illustrates the resistor values and recommended test parameter settings for each type of test. Pay close attention to the duty cycle limitations in the specifications in order to avoid damaging the TVB-2 load box.

ACW DCW IR GC GB

PASS

FAIL

Instrument

Settings

Ramp

2MΩ

120kΩ

1240V

10mA

2s

2MΩ

120kΩ

2121V

5000uA

2s

4MΩ

1MΩ

500V

2MOhm

N/A

500mΩ

2Ω

1Ω

N/A

50mΩ

200mΩ

30A

100mΩ

N/A

WARNING:

The test voltages and currents which can cause harmful or fatal electric shock. To prevent accidental injury or death, these safety procedures must be strictly observed when handling and using the test instrument.

Les tensions et les courants qui peuvent causer des chocs électriques dangereux ou fatal. Pour éviter les blessures accidentelles ou la mort, ces procédures de sécurité doivent être strictement observées lors de la manipulation et l'utilisation de l'instrument de test

Not rated for measurements within MEASUREMENT CATEGORIES

II, III, or IV

N’est pas classé pour les catégories de surtension II, III ou IV

TVB-2 Instructions V1.03 Item #39372

Instruments for Electrical

Safety Testing . . . Since

1936

DO NOT TOUCH WHEN TESTING OR AFTER A MALFUNCTION

HAS OCCURRED.

NE TOUCHEZ PAS LORS DE L'ESSAI OU APRÈS UN

DYSFONCTIONNEMENT DU PRODUIT

CAUTION: Never connect TVB-2 to any mains circuit directly

ATTENTION: Ne jamais connecter directement le TVB-2 à un circuit d'alimentation.

MAINTENANCE:

To prevent electric shock do not remove the instrument cover. There are no user serviceable parts inside. Routine maintenance or cleaning of internal parts is not necessary. Any external cleaning should be done with a clean dry or slightly damp cloth. Avoid the use of cleaning agents or chemicals to prevent damage plastic parts or lettering.

ENTRETIEN:

Pour éviter les chocs électriques ne pas enlever le couvercle de l'instrument. Il n'y a aucune pièce reparable par l'utilisateur. L'entretien de routine ou le nettoyage des pièces internes ne sont pas nécessaires. Tout nettoyage externe doit être fait avec un chiffon sec ou légèrement humide. Éviter l'utilisation de produits de nettoyage ou des produits chimiques pour éviter d’effacer les lettres ou d’abimer les pièces en plastique.

OPERATING ENVIRONMENT:

This instrument may be operated in environments with the following limits:

- Indoor Use Only

- Altitude: 2000 m

- Temperature: 0ºC to 40ºC

- Humidity: Maximum 80% RH at 31ºC decreasing to 50% RH at 40ºC

- Pollution Degree: 2

TVB-2 Instructions V1.03 Item #39372

Instruments for Electrical

Safety Testing . . . Since

1936

Options

Opt. 01 Test Line Cord (p/n 39514)

This optional cable will have the US male plug on one end and high voltage alligator clips on the other end. This cable is not to be plugged directly into a wall outlet. It will be plugged into the Associated Research adapter box p/n 38578. The shorted Line and Neutral are shorted only for

ACW, DCW and IR test verification with the TVB-2.

Figure 1 Line Cord

TVB-2 Instructions V1.03 Item #39372