Comnet C2 Datasheet

Add to My manuals
1 Pages

advertisement

Comnet C2 Datasheet | Manualzz

Rack Mount Card Cage With Redundant Power Supply

C2

The C2 incorporates two C1PS Power Supply units that provide redundancy in the unlikely event of a power supply failure. Two AC line cords (one per power supply module) are provided, allowing each supply to be connected to a separate uninterruptible power supply, providing the highest level of reliability in mission-critical applications. An audio alarm provides an aural indication in the event that one of two power supply modules has failed. The design approach employed by ComNet for equipment mounted within the model C2 chassis rack unit with two modular C1PS power supplies, provides for the elimination of a single-point failure in the event of a major fault within any module located within the chassis rack. This is accomplished through the use of automatic electronic current limiting within each rack-mountable module, rather than providing the current limiting within the power supply unit which supports the power requirements for equipment located within the rack. In nearly all competing designs, a major fault within a module, located within the chassis rack, results in the power supply unit going into a current limiting condition, and as a result, all of the modules within the rack shut down. The C2 rack design employed by ComNet eliminates this possibility, as only the faulty module shuts down, and the operation of the other modules within the rack continue unimpaired. This automatic current limiting feature is also self-resetting, should the fault or overload be of a temporary or intermittent condition. Furthermore, all modules located within the chassis rack are hot-swappable, so that it is not necessary to power-down the rack when removing or replacing modules.

SPECIFICATIONS FEATuRES

› utilizes two C1PS power supply modules in a fault-tolerant / redundant configuration

› Automatic electronic current limiting feature

› Failure relay (NO) for local or remote loss of power indication

› Audio alarm in the event of power supply failure

› Voltage transient protection on all power and signal input/ output lines provides unconditional protection from power surges and other voltage transient events.

› (12) twelve 1-inch rack slots available

› All modules located within the chassis rack are hot-swappable

› Lifetime Warranty

Electrical

Input Voltage

Output Voltage

Fusing

Power Indicator

AC Line Cord

90-264 VAC @ 70 W Maximum

9 VDC +/- 5% @ 6.5 Amps @ 75˚C

1.25 A slow blow (rack power supply)

Plug-in modules individually electronically fused.

Each power supply unit is individually fused.

Red LED

(2) Detachable, IEC-connected. Allows easy field replacement or exchange for various worldwide AC power plug configurations.

ORDERING INFORMATION

Mechanical

Size (L × W × H)

Part Number Description

C2-US

C2-EU

C2-IN

C2-CH

C1PS

19” Rack (US AC Power Cord)

19” Rack (EU & UK Power Cord)

19” Rack (US, EU, UK & AU Power Cord)

19” Rack (no power supply)

Spare 90-264 VAC Input Power Supply

(order power cords separately)

Included Accessories 90-264 VAC Input (includes 2 power supplies and 2 power cords)

Included with C2-US, C2-EU and C2-IN only

Options C1-BP – Blank Panel (1”)

C1-BP2 – Blank Panel (2”)

C1-BP3 – Blank Panel (3”)

C1-SA – South African Power Cord

C1-AU – Australian Power Cord

Rack Mount:

Rack Slots:

Shipping Weight:

Environmental

Operating Temp

Storage Temp

Heat Generation

AGENCY COMPLIANCE *

19.0 × 7.5 × 6.9 in. (48.2 × 19 × 17.5 cm)

(12) 1-inch slots available

<5 lbs./2.15 kg

-40˚ C to +75˚ C

-40˚ C to +85˚ C

240 BTU

*Power Supply Only

In a continuing effort to improve and advance technology, product specifications are subject to change without notice.

3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300

| F: 203.796.5303

| TECH SUPPORT: 1.888.678.9427

| [email protected]

8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]

advertisement

Related manuals

Frequently Answers and Questions

What is the Comnet C2?
The Comnet C2 is a rack mount card cage with redundant power supply.
What are the key features of the Comnet C2?
Automatic electronic current limiting, failure relay for local or remote loss of power indication, audio alarm in the event of power supply failure, and voltage transient protection on all power and signal input/output lines.
What are the specifications of the Comnet C2?
Utilizes two C1PS power supply modules in a fault-tolerant / redundant configuration, (12) twelve 1-inch rack slots available, and all modules located within the chassis rack are hot-swappable.
What is the operating temperature range of the Comnet C2?
The operating temperature range is -40˚ C to +75˚ C.
What is the included accessories of the Comnet C2?
90-264 VAC Input (includes 2 power supplies and 2 power cords).
What is the warranty of the Comnet C2?
Lifetime Warranty.