Paradyne 3165 Quick Reference


Add to my manuals
23 Pages

advertisement

Paradyne 3165 Quick Reference | Manualzz
ACCULINK 3165 DSU/CSU
QUICK REFERENCE
Document No. 3165-A2-GL11-40
Copyright 1998 Paradyne Corporation.
All rights reserved.
Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be
copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated
into any human or computer language in any form or by any means, electronic,
mechanical, magnetic, manual or otherwise, or disclosed to third parties without the
express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo,
FL 33773.
Paradyne Corporation makes no representation or warranties with respect to the
contents hereof and specifically disclaims any implied warranties of merchantability or
fitness for a particular purpose. Further, Paradyne Corporation reserves the right to
revise this publication and to make changes from time to time in the contents hereof
without obligation of Paradyne Corporation to notify any person of such revision or
changes.
Changes and enhancements to the product and to the information herein will be
documented and issued as a new release to this manual.
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
Via the Internet: Visit the Paradyne World Wide Web site at
http://www.paradyne.com
Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A, call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.
Trademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.
TM
ACCULINK 3165 DSU/CSU
Quick Reference
Document Number 3165-A2-GL11-40
November 1998
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select Service & Support → Technical Manuals → T1/E1 Digital Access Devices.
Select the following document:
Document No. 3160-A2-GB21
ACCULINK 316x Data Service Unit/Channel Service Unit Operator’s Guide
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Before installing the DSU/CSU, read the Important Safety Instructions beginning on
page 17.
1
Quick Start Procedure
The following procedure is for experienced DSU/CSU users who are familiar with the
3165 DSU/CSU installation process and have no special requirements for their
application. See the ACCULINK 316x Data Service Unit/Channel Service Unit
Operator’s Guide for more information.
1. Attach the power cord to the rear of the DSU/CSU and the other end to a grounded
115 Vac power outlet.
2. Attach the 3165 DSU/CSU network connection to the T1 network using the
appropriate cable. Attach the 3165 DSU/CSU to the customer premises equipment
via the port connector.
3. Power on the DSU/CSU to perform the power-up self-test.
4. If you intend to use front panel emulation, connect the cable from the PC to the
COM port on the rear panel of the DSU/CSU.
5. If you intend to manage the 3165 DSU/CSU with SNMP, cable either the COM or
MODEM port (as appropriate for your configuration). Then, configure the SNMP
management link.
6. The Factory 1 configuration for ESF framing format and B8ZS line coding format is
the default configuration and is appropriate for most networks. If this configuration
does not work for you, try the Factory 2 configuration for D4 framing format and
AMI line coding format. To further customize configuration options, refer to
Changing Configuration Options in Chapter 3, Operation, and to Appendix C,
Configuration Options, in the ACCULINK 316x Data Service Unit/Channel Service
Unit Operator’s Guide.
7. During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice.
When the test is complete, verify that the DSU/CSU is functional by observing that
the OK and NETWORK SIG LEDs are lit.
2
PSTN
Modem
Modem
or
or
PC
Terminal
SNMP Manager
Workstation
COM
Port
Modem
Port
COM PORT MODEM
POWER
AUX PORT
NEC
CLASS 2
INPUT
Modem
Port
Network
Port
NETWORK
DTE
Front
Panel
3165 DSU/CSU
3165
DSU/CSU
Network
Port
CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK
T1 Network
COM Port
Power
Serial
Port
3165
DSU/CSU
COM PORT MODEM
POWER
AUX PORT
NEC
CLASS 2
INPUT
CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK
Power
or
or
T1 or Serial Connections
Dial Connections
Terminal
NETWORK
DTE
Network
Port
SNMP Manager
Workstation
97-15578
Cabling Examples
3
Configuration Options
Configuration options are accessed from the Configuration branch of the front panel
menu.
DSU ESF
Stat
Test
DevHS STest Perf TStat LED
Telco User
Prtn
Ctrl
Rel
ID
Rlpbk
Reset
Lpbk
Cur Intvl
8Tot
Dial Disc ChDir
Ptrns Lamp
LLBUP 54UP
FT1UP
LLBDN 54DN
FT1DN
User Prt1
1 . . 5,A
1 . . 5,A
(Directory) (Directory)
Abort Send Mon
Passwd
CID
ClrReg
Call
T1 Prtn
Near Far
Cur Intvl
24Tot
Cnfig
Near
Far
QRSS 511
QRSS 1in8 511
Abort LLB PLB DLB RLB DCLB DTLB
Load Edit Area From:
Activ
Cust1 Cust2 Fact1
Fact2
Choose Function:
Save
Edit
Activ Cust1 Cust2
Port
NET
Chan
Gen
Dsply Clear
User
Alarm
Mgmt
Gen Trap
4
97-15579
DL
Factory default configuration options are shown in boldface type in the following tables.
Table 1. Port Configuration Options (1 of 2)
Option
Factory 1
Factory 2
E530
E530
V.35
V.35
RS449
RS449
X.21
X.21
Nx64
Nx64
Nx56
Nx56
Disab
Disab
V.54
V.54
FT1
FT1
Both
Both
Disab
Disab
DTLB
DTLB
DCLB
DCLB
Both
Both
Disab
Disab
DTR
DTR
RTS
RTS
Both
Both
None
None
Halt
Halt
Int
Int
Ext
Ext
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Port Type:
Base Rate:
Net DCLB:
Port LB:
All Ones:
Rcv Yellow:
(Received Yellow)
Tx Clock:
InvertTxC:
(Invert Tx Clock)
InvertData:
5
Comments/Description
Selects the port type: EIA-530A,
V.35, RS449, or X.21.
Enables the port to either Nx56 or
Nx64 rates.
Network-initiated DCLB,, allows
DCLB to be controlled by inband
(
) codes.
V.54 or FT1 (ANSI)
Port-initiated Loopbacks,
p
, allows
Loopbacks to be initiated through
e po
ee
e a DTE.
the
port by the
external
All ones sent to network (DTE) T1
when DTR or RTS interrupted.
Data p
port remains enabled,, or is
disabled on receiving Yellow on
disabled,
network T1.
Selects whether the transmitted
data clock is internal (TXC) or
external (XTXC).
Selects phase inversion of the
transmit clock (TXC).
Allows the data on the port to be
inverted.
Table 1. Port Configuration Options (2 of 2)
Option
Err Rate:
(Excessive Error
a e)
Rate)
Factory 1
Factory 2
10E–4
10E–4
10E–5
10E–5
10E–6
10E–6
10E–7
10E–7
10E–8
10E–8
10E–9
10E–9
Comments/Description
Selects the error rate threshold for
Excessive Error Rate Alarm.
Alarm
Table 2. Network Interface Configuration Options
Option
NET Framing:
NET Coding:
LBO:
ANSI PRM:
Mgmt Link:
NET LLB:
Factory 1
Factory 2
D4
D4
ESF
ESF
AMI
AMI
B8ZS
B8ZS
0.0
0.0
–7.5
–7.5
–15
–15
–22.5
–22.5
Enab
Enab
Disab
Disab
Disab
Disab
SNMP
SNMP
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
NET PLB:
BitStuff:
Circuit Ident:
62411
62411
Part68
Part68
Disab
Disab
Edit
Edit
Clear
Clear
6
Comments/Description
Selects D4 or ESF framing format.
format
Selects AMI or B8ZS line coding
format.
Provides Line Build Out in dB.
dB
Sends ANSI Performance Report
Messages.
Specifies whether the FDL’s
FDL s
Management Link is enabled.
Network-initiated LLB allows LLB to
be controlled by inband LLB codes.
Network-initiated PLB allows PLB
to be controlled by FDL PLB
messages.
Provides enforcement of ones
d
density
it protection
t ti per AT&T TR
62411, ANSI T1-403, and FCC
Part 68 Technical Publication.
Specifies the transmission vendor’s
vendor s
circuit identifier.
Table 3. Channel Configuration Options (1 of 2)
Option
Factory 1
Factory 2
Block
Block
Assign By:
ACAMI
ACAMI
Chan
Chan
Port Rate:
64 (56)
128 (112)
192 (168)
256 (224)
320 (280)
384 (336)
448 (392)
512 (448)
576 (504)
640 (560)
704 (616)
768 (672)
832 (728)
896 (784)
960 (840)
1024 (896)
1088 (952)
1152 (1008)
1216 (1064)
1280 (1120)
1344 (1176)
1408 (1232)
1472 (1288)
1536 (1344)
64 (56)
128 (112)
192 (168)
256 (224)
320 (280)
384 (336)
448 (392)
512 (448)
576 (504)
640 (560)
704 (616)
768 (672)
832 (728)
896 (784)
960 (840)
1024 (896)
1088 (952)
1152 (1008)
1216 (1064)
1280 (1120)
1344 (1176)
1408 (1232)
1472 (1288)
1536 (1344)
7
Comments/Description
Determines how channels are
assigned: contiguous blocks,
ACAMI or individual
i di id l channels.
h
l
Selects the data rate for the port.
The possible rates depend on
whether the port is configured for
Nx56 or Nx64.
This configuration option only
appears if the “Assigned By”
configuration option is Block or
ACAMI.
Table 3. Channel Configuration Options (2 of 2)
Option
Start At:
Line 1 Displays:
Factory 1
Clear
Clear
N1 (D1)
N2 (D2)
N3 (D3)
N4 (D4)
N5 (D5)
N6 (D6)
N7 (D7)
N8 (D8)
N9 (D9)
N10 (D10)
N11 (D11)
N12 (D12)
N13 (D13)
N14 (D14)
N15 (D15)
N16 (D16)
N17 (D17)
N18 (D18)
N19 (D19)
N20 (D20)
N21 (D21)
N22 (D22)
N23 (D23)
N24 (D24)
N1 (D1)
N2 (D2)
N3 (D3)
N4 (D4)
N5 (D5)
N6 (D6)
N7 (D7)
N8 (D8)
N9 (D9)
N10 (D10)
N11 (D11)
N12 (D12)
N13 (D13)
N14 (D14)
N15 (D15)
N16 (D16)
N17 (D17)
N18 (D18)
N19 (D19)
N20 (D20)
N21 (D21)
N22 (D22)
N23 (D23)
N24 (D24)
Line 2 Displays:
Meaning
—
Unassigned
Prt1
Channel assigned
to port 1
D1, D2 ... D24
Channel assigned
to this DTE
channel
N1 N2 N3 ...... N24:
(If assigned to NET)
D1 D2 D3 ..... D24:
(If assigned to DTE)
Factory 2
N1, N2 ... N24
Channel assigned
to this NET
channel
8
Comments/Description
Clears (unassigns) channels for
this port.
This configuration option appears if
the “Assigned By” configuration
option is Block or ACAMI.
Comments/Description
This configuration option appears if
the “Assigned
By”
g
y configuration
g
option is individual channels
(Chan).
Function key under the channel
(N1 N2 etc.)
(N1,
t ) assigns
i
(
(unassigns)
i
)
port (1, 2, 3, or 4) to that channel.
Table 4. General Configuration Options
Option
Gen Yellow:
(Generate Yellow)
Clock Src:
Clock Rate:
Factory 1
Factory 2
Enab
Enab
Disab
Disab
NET
NET
DTE
DTE
Prt1
Prt1
Int
Int
Ext
Ext
2048
2048
1544
1544
8
8
Enab
Enab
Disab
Disab
10
10
Up
Up
Down
Down
Save
Save
Tst Timeout
Tst Duration
9
Comments/Description
Yellow alarm is generated by the
DSU/CSU on LOS, LOF, or AIS.
Selects the clock source to be
used as the master clock for the
DSU/CSU
DSU/CSU.
Selects the clock rate of the source
if external.
Specifies
p
whether the durations of
user initiated tests are limited by
user-initiated
Tst Duration.
Specifies the duration of
user-initiated
i i i d loopback
l
b k and
d pattern
tests.
Table 5. User Configuration Options (1 of 3)
Option
Factory 1
Factory 2
Enab
Enab
Disab
Disab
Self-Test:
FP Access:
FP Pass:
Dial-In:
Password:
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
None
None
Com
Com
Modem
Modem
Both
Both
Mgmt
Mgmt
ASCII
ASCII
Daisy
Daisy
Term
Term
Async
Async
Sync
Sync
Com Use:
Com Type:
Com Clk:
Com Rate:
(Communication Port
R t )
Rate)
Int
Int
Ext
Ext
1.2
1.2
2.4
2.4
4.8
4.8
9.6
9.6
14.4
14.4
19.2
19.2
38.4
38.4
7
7
8
8
None
None
Even
Even
Odd
Odd
Char Length:
CParity:
((Communication Port
Parity)
10
Comments/Description
Allows bypass of self-test on
initialization.
Controls whether front panel
access or display is allowed.
Controls whether front panel
pass-through is allowed.
Controls whether dial-in access is
allowed.
Controls whether a password is
required during a call setup.
Controls how the COM port is
used.
Controls whether the COM port is
synchronous or asynchronous.
Controls whether the COM port
uses an internal or external clock.
Selects the bit rate for the COM
port.
Selects the character length for the
COM port.
Selects the parity
p y for the COM port.
p
Table 5. User Configuration Options (2 of 3)
Option
CStop Bits:
(Communication Port
St Bits)
Stop
Bit )
Factory 1
Factory 2
1
1
1.5
1.5
2
2
Yes
Yes
No
No
Enab
Enab
Disab
Disab
5
5
Up
Up
Down
Down
Save
Save
Ignore DTR:
CmInActTm:
(COM Port Inactivity
Timeout)
CmDiscTm:
(COM Port
Disconnect Time)
Modem Use:
Mgmt
Mgmt
ASCII
ASCII
Term
Term
Async
Async
Sync
Sync
1.2
1.2
2.4
2.4
7
7
8
8
None
None
Even
Even
Odd
Odd
1
1
2
2
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Modem Type:
Modem Rate:
MChar Len:
(Modem Port
Character Length)
MParity:
(Modem Port Parity)
MStop Bits:
(Modem Port Stop
Bits)
LSpaceDsc:
p
(Long Space
Disconnect)
MoInActTm:
(Modem Port
Inactivity Timeout)
11
Comments/Description
Selects the number of stop bits for
the COM port.
Specifies whether the COM port
ignores DTR.
Specifies
p
whether the
communication port disconnects
after a certain period of inactivity.
Specifies the period of inactivity
(1 to 60 minutes) that causes a
disconnect if CmInActTm is
enabled.
Controls whether the MODEM port
is used for SNMP management.
Controls whether the MODEM port
is synchronous or asynchronous.
Selects the bit rate for the MODEM
port.
Selects the character length for the
MODEM port.
Selects the parity for the MODEM
port.
Selects the number of stop bits for
the MODEM port.
Selects the long
g space
p
disconnect
configuration option for terminating
modem connections.
Specifies
p
whether the modem p
port
disconnects after a certain period
of inactivity.
Table 5. User Configuration Options (3 of 3)
Option
MoDiscTm:
(Modem Port
Disconnect Time)
TnSession:
(Telnet Session)
TnPaswd:
(Telnet Password)
TnInActTm:
(Telnet Inactivity
Timeout)
TnDiscTm:
(Telnet Disconnect
Time)
Factory 1
Factory 2
5
5
Up
Up
Down
Down
Save
Save
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
5
5
Up
Up
Down
Down
Save
Save
12
Comments/Description
Specifies the period of inactivity
(1 to
t 60 minutes)
i t ) that
th t causes a
d
sco ec if MInActTm
c
se
ab ed
disconnect
is
enabled.
Specifies
p
whether the DSU/CSU
responds to Telnet session
requests.
Specifies whether a password is
required for Telnet sessions.
Specifies
p
whether a Telnet session
disconnects after a certain period
of inactivity.
The period of inactivity (1 to
60 minutes) that causes a
disconnect if TnInActTm is
enabled.
Table 6. Alarm Configuration Options
Option
Factory 1
Factory 2
Comments/Description
Disab
Disab
Does not display alarm messages.
Modem
Modem
Sends alarm messages to Modem
port.
Com
Com
Sends alarm messages to COM
port.
Both
Both
Sends alarm messages to both
ports.
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Enab
Enab
Disab
Disab
Specifies
p
whether an outgoing
g g call
is retried on a busy or failed call
attempt.
Dial Delay:
1–4
5
6–10
1–4
5
6–10
The time (in minutes) to delay
between successive alarm
dial-outs or retry attempts.
AltDialDir:
None
1–5
None
1–5
The alternate dial-out directory to
use if a call to the primary number
cannot be completed.
10E–4
10E–4
10E–5
10E–5
10E–6
10E–6
10E–7
10E–7
10E–8
10E–8
10E–9
10E–9
Al Msg:
Alrm
M
SNMP Trap:
Sends SNMP traps.
traps
TrapDisc:
DialOut:
Call Retry:
Err Rate:
(Excessive Error
Rate)
13
Specifies
p
whether the modem
connection will disconnect after a
trap is sent.
Provides the option
p
to allow
automatic dial-out
dial out to send alarm
messages on MODEM port.
The error rate threshold for
Excessive Error Rate Alarm.
Alarm
Table 7. Management – General Configuration Options (1 of 2)
Option
Factory 1
Factory 2
Disab
Disab
Enab
Enab
Disab
Disab
Enab
Enab
1
2–10
1
2–10
Edit
Edit
Clear
Clear
Read
Read
R/W
R/W
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
SNMP Mgt:
NMS Valid:
Num Sec Mgrs:
NMS n IP Adr:
NMS n ACS:
System Name:
System Location:
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
Read
Read
R/W
R/W
Edit
Edit
Clear
Clear
Read
Read
R/W
R/W
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
System Contact:
CommunityName1:
Access 1:
CommunityName2:
Access 2:
IP Adr:
NetMask:
Com IP Adr:
14
Comments/Description
Specifies
p
whether the DSU/CSU
responds to SNMP session
requests.
Specifies whether the DSU/CSU
validates the IP address of an
SNMP manager attempting
access.
The number of management
systems authorized to send SNMP
messages to this unit.
Specifies
p
the IP address for each
NMS This configuration option is
NMS.
repeated for all n NMSs.
The type of access allowed for
NMS n.
The SNMP system name for this
device.
The SNMP system location for this
device.
The SNMP system contact name
for this device.
A community
y name that is allowed
access to this device.
device Defaults to
public.
The type of access allowed for
community name 1.
A community name that is allowed
access to this device.
The type of access allowed for
community name 2.
The IP address needed to access
the device.
The Subnet Mask needed to
access the device.
The IP address for the COM port
when configured for SNMP.
Table 7. Management – General Configuration Options (2 of 2)
Option
Factory 1
Factory 2
Edit
Edit
Clear
Clear
PPP
PPP
SLIP
SLIP
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
Edit
Edit
Clear
Clear
PPP
PPP
SLIP
SLIP
None
None
Com
Com
Modem
Modem
FDL
FDL
Com NetMask:
Com Link:
Modem IP Adr:
Mdm NetMask:
Alt Mdm IP Adr:
Alt Mdm NetMask:
Modem Link:
Def Netwk:
15
Comments/Description
The Subnet Mask needed to
access the device when the COM
port is configured for SNMP.
The link layer protocol for the COM
port when configured for SNMP.
Specifies
p
the IP address for the
MODEM port when configured for
SNMP.
Specifies the Subnet Mask needed
to access the device when the
MODEM port is configured for
SNMP.
Specifies
p
the alternate IP address
for the MODEM port when
configured for SNMP.
Specifies the alternate modem
Subnet Mask needed to access the
device when the MODEM port is
configured for SNMP.
Specifies
p
the link layer
y p
protocol for
the MODEM port when configured
for SNMP.
Specifies the default network
destination.
Table 8. Management – Trap Configuration Options
Option
Num Trap Mgrs:
Factory 1
Factory 2
1
2–6
1
2–6
The number of trap managers
supported by the device.
Edit
Edit
Clear
Clear
Specifies the IP address for each
trap manager. This configuration
option is repeated for all n
managers.
None
None
Def
Def
Com
Com
Modem
Modem
FDL
FDL
Disab
Disab
Warm
Warm
Auth
Auth
Both
Both
Enab
Enab
Disab
Disab
Disab
Disab
Up
Up
Down
Down
Both
Both
NET
NET
T1s
T1s
Ports
Ports
All
All
Trapn IP Adr:
Trapn Dst:
Gen Trap:
Entp Trap:
Link Trap:
Trap I/F:
Comments/Description
16
Specifies the network destination
for Trap Manager n.
Specifies
p
the g
general trap
p types
yp to
enable: WarmStart,
WarmStart Authentication
Failure or both.
Specifies
p
whether the
EnterpriseSpecific trap type is
enabled.
Specifies
p
the link trap
p type
yp to
enable: Trap on Link Up,
Up Link
Down, or both.
When any
y link trap
p types
yp are
enabled specifies which links to
enabled,
send traps for.
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. This product is intended to be used with a 3-wire grounding type plug – a plug
which has a grounding pin. This is a safety feature. Equipment grounding is vital to
ensure safe operation. Do not defeat the purpose of the grounding type plug by
modifying the plug or using an adapter.
Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle
for the presence of earth ground. If the receptacle is not properly grounded, the
installation must not continue until a qualified electrician has corrected the problem.
If a 3-wire grounding type power source is not available, consult a qualified
electrician to determine another method of grounding the equipment.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
5. Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high voltage points or other risks. Refer all servicing to
qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may
be required by the regulatory inspection authority for the installation site, are the
responsibility of the customer.
7. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.
9. Input power to the ac voltage configuration of this product must be provided by a
UL-listed or CSA-certified power source with a Class 2 or Limited Power Source
(LPS) output. Input power to the dc voltage configurations of this product must be
provided by a National Electric Code (NEC) or a Canadian Electric Code (CEC)
Class 2 circuit.
10. This product contains a coin cell lithium battery that is only to be replaced at the
factory. Caution: There is a danger of explosion if the battery is incorrectly
replaced. Replace only with the same type. Dispose of used batteries according to
the battery manufacturer’s instructions. Attention: Il y a danger d’explosion s’il y a
remplacement incorrect de la batterie. Remplacer uniquement avec une batterie du
même type. Mettre au rebut les batteries usagées conformément aux instructions
du fabricant.
17
11. In addition, if the equipment is to be used with telecommunications circuits, take the
following precautions:
— Never install telephone wiring during a lightning storm.
— Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
— Never touch uninsulated telephone wires or terminals unless the telephone
line has been disconnected at the network interface.
— Use caution when installing or modifying telephone lines.
— Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.
— Do not use the telephone to report a gas leak in the vicinity of the leak.
EMI Warnings
! WARNING:
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements
that no modifications will be made to the equipment unless the changes or
modifications are expressly approved by Paradyne Corporation.
! WARNING:
To Users of Digital Apparatus in Canada:
This Class A digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
règlement sur le matérial brouilleur du Canada.
Government Requirements and Equipment Return
Certain governments require that instructions pertaining to CSU connection to the
telephone network be included in the installation and operation manual. Specific
instructions are listed in the following sections.
18
Notice to Users of the United States Telephone Network
1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label
that contains, among other information, the FCC registration number for this
equipment. The label is on the bottom of the DSU/CSU. If requested, this
information must be provided to the telephone company.
2. There are two types of telephone lines associated with the standalone equipment.
The T1 network connection should be made using a Universal Service Order Code
(USOC) type RJ48C jack. The Service Order Code 6.0F should be specified to the
telephone company when ordering the T1 line. In addition, the proper Facility
Interface Code must be specified to the Telephone Company. The DSU/CSU can
be configured to support any of the following framing format and line signaling
techniques. The DSU/CSU’s configuration must correspond to the T1 line’s
parameters. The DSU/CSU’s internal modem connects to the Public Switched
Telephone Network using a USOC Type RJ11C jack. The Facility Interface Code
02LS2 along with the RJ11C jack should be specified to the telephone company
when ordering a dial line for the modem.
3165 DSU/CSU Facility Interface Codes
Code
Description
04DU9-BN
1.544 Mbps superframe format (SF) without line power
04DU9-DN
1.544 Mbps SF and B8ZS without line power
04DU9-1KN
1.544 Mbps ANSI ESF without line power
04DU-1SN
1.544 Mbps ANSI ESF and B8ZS without line power
3. The ringer equivalence number (REN) is used to determine the quantity of devices
which may be connected to the telephone line. Excessive RENs on the telephone
line may result in the devices not ringing in response to an incoming call. In most,
but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of
the number of devices that may be connected to the line, as determined by the
total RENs, contact the telephone company to determine the maximum RENs for
the calling area.
4. If the DSU/CSU causes harm to the telephone network, the telephone company will
notify you in advance that temporary discontinuance of service may be required.
But if advance notice is not practical, the telephone company will notify the
customer as soon as possible. Also, you will be advised of your right to file a
complaint with the FCC if you believe it is necessary.
5. The telephone company may make changes in its facilities, equipment, operations,
or procedures that could affect the operation of the equipment. If this happens, the
telephone company will provide advance notice in order for you to make the
necessary modifications in order to maintain uninterrupted service.
19
6. If you experience trouble with this equipment, please contact your sales or service
representative (as appropriate) for repair or warranty information. If the product
needs to be returned to the company service center for repair, contact them directly
for return instructions using one of the following methods:
— Via the Internet: Visit the Paradyne World Wide Web site at
http://www.paradyne.com
— Via Telephone: Call our automated call system to receive current information
via fax or to speak with a company representative.
Within the U.S.A., call 1-800-870-2221
Outside the U.S.A., call 1-727-530-2340
If the trouble is causing harm to the telephone network, the telephone company
may request that you remove the equipment from the network until the problem is
resolved.
7. The equipment’s modem cannot be used on public coin service provided by the
telephone company. Connection to Party Line Service is subject to state tariffs.
(Contact the state public utility commission, public service commission or
corporation commission for information.)
8. FCC compliant telephone line cords with modular plugs are provided with this
equipment. This equipment is designed to be connected to the telephone network
or premises wiring using a compatible modular jack which is Part 68 compliant.
Notice to Users of the Canadian Telephone Network
The Industry Canada label identifies certified equipment. This certification means that
the equipment meets telecommunications network protective, operational and safety
requirements as prescribed in the appropriate Terminal Equipment Technical
Requirements document(s). The Department does not guarantee the equipment will
operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The equipment
must also be installed using an acceptable method of connection. The customer should
be aware that compliance with the above conditions may not prevent degradation of
service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by
the supplier. Any repairs or alterations made by the user to this equipment, or
equipment malfunctions, may give the telecommunications company cause to request
to disconnect the equipment.
CAUTION:
Users should not attempt to make such connections themselves, but should
contact the appropriate electric inspection authority, or electrician, as
appropriate.
20
The Ringer Equivalence Number (REN) assigned to each terminal device provides an
indication of the maximum number of terminals allowed to be connected to a telephone
interface. The termination on an interface may consist of any combination of devices
subject only to the requirement that the sum of the Ringer Equivalence Numbers of all
the devices does not exceed 5.
If your equipment is in need of repair, refer to Warranty, Sales, and Service Information
in the front of this document.
21

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement