Pan Connection
125
Important
22mm projection from wall
Mark centre line of pan on wall.
This can be offset by up to 50mm from the soile pipe, as detailed in Fig. 2.
1/2” B.S.P.
Nipple
Important:
Pan foot level
Finished wall
Fig. 1
‘S’ Trap Bedding Installation
Push pan onto
Uni-Orbital ® connector
Level pan when bedding
Fig. 4
Fixing Hole
Cover Detail for Bedding
Installations
Blanking
Cap
Fig. 7
Pan Foot
Bracket Fixing
Detail
Plastic sleeve
D82 Concealed fixing bracket
Fig. 8
Cap
Fixing head
Pan foot
Threaded stud
Silicone bedding
D82 Concealed Fixing Brackets
Cap
Plastic Sleeve
Fig. 9
10mm bedded position 5mm silicone
140mm Recommended Range 60mm - 200mm
Concealed
Fixing Bracket
Pan Uni-Orbital ® Connector
Set-Out Dimension 'A'
50
Uni-Orbital
®
connector can be positioned anywhere in shaded area in a 50mm arc
Waste outlet
Pan seal
Finished Wall
“A”
Pan foot level
Recommended set-out dimension 140mm
Set-out range
60mm - 200mm
Fig. 2
100mm PVC DWV soil pipe
‘P’ Trap Bedding Installation
Level pan when bedding
Push pan onto connector
Fig. 5
Pan outlet
185
225
10 mm bedded position 5mm silicone
Cistern
Winged fixing bolt
Seal
Pan
Captured nut toggle
Pan foot level
Preparation For Bedding
Finished Wall
225
Fixed installation dimension for all set-outs
Fig. 3
Relieve bed around pan connector
Important
Pan foot level
Bottom Inlet Cistern Fixing
Cistern
Flexible hose
*
Bed height
60mm
*
140mm Recommended
Inlet Valve
Flexible hose
PLUMBERS INSTALLATION INSTRUCTIONS
For Vitreous China Urbane Wall Faced Close Coupled Toilet Pan
PLEASE READ CAREFULLY BEFORE INSTALLATION
ROUGHING IN:
The Urbane pan is universal for both ‘S’ and ‘P’-Trap installations as detailed. The recommended set-out for ‘S’-Trap installations is 140mm from the finished wall with set-out flexibility for existing soil pipe positions ranging from 60mm to
200mm and 50mm sideways adjustment with the Uni-Orbital connector supplied, as detailed in Fig. 2.
®
IMPORTANT - FOR BOTTOM INLET, BEFORE INSTALLING
PAN, FEED FLEXIBLE HOSE THROUGH SIDE OF PAN AND
UP TO ENABLE EASY CONNECTION TO CISTERN INLET
VALVE (REFER TO FIG. 6.)
‘S’- TRAP CONNECTOR FIXING PROCEDURE
1- Mark centre line of the pan on finished wall, as detailed in
Fig. 1. This is to be used as a guide when connecting the
pan. The centre line can be offset by up to 50mm from the
soil pipe, as detailed in Fig. 2.
2- Determine set-out "A" of existing pan connector, as detailed
in Fig. 2. Set-out range 60mm - 200mm. Recommended
set-out 140mm, as detailed in Fig. 3. For ‘P’ trap installation
see
3- For installation of the Uni-Orbital ® connector, reference must
be made to the instructions supplied with the connector.
4- Prepare for pan fixing method (either bedding or bracket
installation) as detailed below.
2- Locate the D82 Concealed Fixing brackets into position on
centre line of pan 280mm from the finished wall and mark
bracket fixing hole centres on finished floor.
3- Drill two holes in the marked positions on the floor. The
hole diameter is dependent on the type of fixing system
and floor finish.
4- Secure Brackets to finished floor.
5- Ensure that the area around the floor is clean and free from
building material.
6- Run a bead of acetic cured silicone sealant at a height of
8mm approximately fully around the foot of the pan which
contacts the floor. Use Wedges around the foot base (if
required) so that the maximum height of silicone sealant
is not greater that 5mm on completion on bedding.
7- Connect pan to connector and locate plastic fixing sleeve
into holes in the pan. Fit screw into the bracket and tighten
to bed pan to floor while ensuring level, as detailed in
Fig. 8.
IMPORTANT-DO NOT OVER TIGHTEN, AS THIS MAY
CRACK THE PAN FOOT. Snap on plastic cap, as detailed
8- Provide support under the pan foot so that it is maintained
in the levelled position while the silicone sealant sets.
Remove any excess sealant to provide a neat joint
between the pan and the floor. Allow at least 24 hours for
the bedding sealant to set before use.
Fig. 6
Foam seal
140 recommended range 60 – 200mm with Uni-Orbital
®
supplied
(up to 50mm sideways adjustment)
Pan outlet
D82 Concealed Bracket
Fixing Centre
185
280
Fig. 10
PAN/CLOSET FIXING PROCEDURE
Pan bedding:
1- Remove an area of tiles which are within the internal area
covered by the foot of the pan to expose the sub floor and
provide a bondage key for the bedding mixture.
2- Ensure that the bedding area is clean and free of building
material.
3- Locate blanking cap (supplied) into pan fixing holes as
detailed in Fig. 7.
4- Prepare bedding sand cement mixture 3:1 to depth of 60mm as detailed in Fig. 3. Note: Do not fill the foot of the pan with
bedding mix or include lime or fast drying cement into the mix,
these may cause cracking in the foot of the pan.
5- Position and push pan into Uni-Orbital ® connector using the
marked centre line on the wall as a guide and level pan into
bedding mixture, so that the back of the foot of the pan is
approximately 10mm above the finished floor as detailed in
Fig. 4. It is recommended that wedges are used to support
the foot of the pan during the positioning.
6- Locate the cistern on to the pan and check that the cistern is
level (side to side) and aligned with the tiling edges. Adjust
pan position if necessary. Allow bedding mixture to set for at
least 24 hours prior to use.
Bracket fixing:
1- Position and push pan into Uni-Orbital ® connector using the
marked centre line on the wall as a guide and locate the
cistern onto the pan, checking that the cistern aligns with
the finished wall. Adjust pan position if necessary. Remove
the cistern and pan.
IMPORTANT
TO ACHIEVE A SATISFACTORY 4.5/3L
FLUSH PERFORMANCE AND A 4 STAR
WATER EFFICIENCY RATING THE CISTERN
MUST BE MATCHED WITH A COMPATIBLE
CAROMA SMARTFLUSH 4.5/3L TOILET PAN.
All measurements are subject to accepted manufacturing tolerances.
To ensure accuracy please check actual product dimensions before drilling for installation.
The manufacturer reserves the right to change specifications at any time without giving prior notification.
This product should be installed by a qualified plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements.
Issue No: 1
Date of Issue: 29/10/13
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project