Datasheet: OptiFiber® Pro OTDR
Accelerates enterprise fiber troubleshooting and certification.
The OptiFiber Pro OTDR is the Tier 2
(extended) fiber certification solution and part of the Versiv™ Cabling Certification product family. The Versiv line also includes copper certification, OLTS and Wi-
Fi analysis modules. Versiv is designed around the revolutionary ProjX™ management system and Taptive™ user interface. ProjX tracks jobs to ensure they're done correctly the first time, thus reducing rework. With the intuitive Taptive user interface, instrument set-up and operation are so simple, even operators with limited cabling skills can successfully test and troubleshoot a system. Analysis of measurement data and professional test reports are easy with the familiar
LinkWare™ management software.
Get ready to overachieve.
Designed for enterprise fiber
As enterprise networks and datacenter architectures evolve, IT infrastructure administrators demand better OTDR technology to maintain fiber network performance. Many OTDRs (Optical
Time Domain Reflectometers) used for fiber troubleshooting are designed for carriers and contain cumbersome and complicated features that enterprise users don’t need. Few OTDRs are built with features and usability for enterprise network engineers, SAN designers and cable installers.
As enterprises consume more storage resources and adopt higher bandwidth (40G, 100G) datacenter architectures, the resilience of the cabling infrastructure becomes highly dependent upon maintenance tools to ensure fiber reliability. OptiFiber Pro is the industry’s first purposebuilt OTDR that meets the unique challenges of an enterprise fiber infrastructure. With its simple
Taptive user interface and powerful feature set, the OptiFiber Pro turns anyone into an efficient and expert premise fiber troubleshooter or installer.
Unique features:
Versiv enables users to accomplish more than ever with a cable tester, accelerating every step of the testing process
ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.
Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of of technicians of all skill levels.
LinkWare management software provides unmatched analysis of test results and professional test reports
Performance:
Test times as short as two seconds in Quick Test mode
Quickly test datacenter fiber with pre-programmed settings
Troubleshoot datacenter fiber links with short patch cables and many connectors because of ultra short dead zones
Easily characterize all connectors, splices and areas of high loss with graphical
EventMap™ view
ProjX management system increases return on investment by enabling OTDR project sharing among users and different jobs
Reduce network downtime by quickly and precisely identifying faults on all fiber types
Built-in Visual Fault Locator (VFL) easily identifies damaged fibers.
http://www.elso.sk
1 of 9
riešenia na presné meranie
Standards:
Full OTDR capability that certifies fiber performance based on industry standards or customer specifications
Complaint with ISO and TIA standards
Unique certification with flexibility and efficiency
An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With ProjX management system, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.
Advantages:
Powerful ProjX management system facilitates OTDR sharing with clear job assignment for each operator
Easy monitoring of job progress with pass/fail results
Built-in Visual Fault Locator (VFL) to facilitate troubleshooting
On-screen report generation and upload to LinkWare™ application
Taptive user interface
Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro has the
Taptive user interface which combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.
View traces Pinch and zoom in for trace detail
Optimized for the datacenter
Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead-zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.
Advantages:
Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
Datacenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
The EventMap feature depicts fiber events in a way that requires no trace analysis expertise http://www.elso.sk
2 of 9
riešenia na presné meranie
Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.5 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area network environments.
Extremely short event and attenuation dead zone
Two second trace per wavelength
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap event, Table or Trace. The end result is less time spent testing and more time performing other tasks.
DataCenter OTDR mode
DataCenter OTDR™ mode
With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine tuning as needed in legacy OTDRs.
DataCenter OTDR mode automatically detects OTDR parameters – end-detection algorithms, pulse widths – without getting confused by the short links or number of connectors.
http://www.elso.sk
3 of 9
riešenia na presné meranie
Graphical EventMap™ view
To eliminate the learning curve associated with reading an OTDR trace, OptiFiber Pro’s advance logic automatically interprets the information to create a detailed and graphical map of events that includes connectors, splices and anomalies. To accommodate different preferences, users can easily switch between the EventMap, the Event Table and the Trace for test details. Any faulty events will be highlighted with RED icons to facilitate quick troubleshooting.
On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.
Graphical EventMap™ view - PASS Eventmap™ - FAIL. See Help icon for on screen corrective action.
Dynamic project and user profile management with ProjX management system
OptiFiber Pro enhances job efficiency by allowing the project manager to create and manage operator and job profiles per project. Defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.
ProJX: Dynamic project and user profile management http://www.elso.sk
4 of 9
riešenia na presné meranie
FiberInspector™ probe
OptiFiber Pro’s video inspection system examines patch cords and patch panel bulkheads to avoid the number one cause of fiber link failure – contamination. Significant time is saved because the probe is inserted directly into the patch panel’s bulkhead to examine installed fiber terminations without disassembling the patch panel. Technicians assign a pass or fail grade to the fiber, can add a comment and save it for use in certification reports.
FiberInspector probe
LinkWare™ Management Software
With LinkWare management software, OptiFiber Pro users can easily access the ProjX management system data, generate reports and upgrade the software in their testers. Project managers have full capabilities to monitor workflow and consolidate test results. LinkWare stats, provides automated statistical reports. This application moves you above and beyond the page-per-link report to see your entire cabling infrastructure in one summary. It analyzes and transforms LinkWare test results into charts to reveal your cabling plant performance. The report even summarizes your entire cabling infrastructure in a compact, graphical format so it's easy to verify margins and spot anomalies. Previous versions of LinkWare are backwards compatible with new versions, so you can stay current and integrate tests from different testers into one-test report. Combine
OLTS Tier 1 (basic) and OTDR Tier 2 (extended) fiber certification results in a single report while allowing management of multiple jobs simultaneously. Users can provide the finishing touch by adding their company logo to the report and before offering to their customers for system acceptance. Keep your business tools simple. No matter which Fluke Networks cabling certification tester you use, LinkWare reports it all.
LinkWare Report
http://www.elso.sk
5 of 9
riešenia na presné meranie
Key OTDR specifications
Wavelengths
Compatible fiber types
Event dead zone 1
Attenuation dead zone 2
Dynamic range
3, 5, 6
Max distance range setting
Distance measurement range 4, 5, 7, 8, 9, 10
Reflectance range
Sample resolution
4, 5
Mutimode module
850 nm +/- 10 nm
1300 nm +35/-15 nm
50/125 µm
62.5/125 µm
850 nm: 0.5 m (typical)
1300 nm: 0.7 m (typical)
850 nm: 2.5 m (typical)
1300 nm: 4.5 m (typical)
850 nm: 28 dB (typical)
1300 nm: 30 dB (typical)
40 km
850 nm: 9 km
1300 nm: 35 km
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
3 cm to 400 cm
Singlemode module
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Singlemode
1310 nm: 0.6 m (typical)
1550 nm: 0.6 m (typical)
1310 nm: 3.6 m (typical)
1550 nm: 3.7 m (typical)
1310 nm: 32 dB (typical)
1550 nm: 30 dB (typical)
130 km;
1310 nm: 80 km
1550 nm: 130 km
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
3 cm to 400 cm
Quad module
850 nm +/- 10 nm, 1300 nm +35/-15 nm, 1310 nm
+/- 25 nm, 1550 nm +/- 30 nm
50/125 μm, 62.5/125 μm, Singlemode
850 nm: 0.5 m (typical), 1300 nm: 0.7 m (typical),
1310 nm: 0.6 m (typical), 1550 nm: 0.6 m (typical)
850 nm: 2.5 m (typical), 1300 nm: 4.5 m (typical),
1310 nm: 3.6 m (typical), 1550 nm: 3.7 m (typical)
850 nm: 28 dB (typical), 1300 nm: 30 dB (typical),
1310 nm: 32 dB (typical), 1550 nm: 30 dB (typical)
MM: 40 km, SM: 130 km
850 nm: 9 km, 1300 nm: 35 km, 1310 nm: 80 km,
1550 nm: 130 km
850 nm: -14 dB to -57 dB (typical), 1300 nm: -14 dB to -62 dB (typical), 1310 nm: -14 dB to -65 dB
(typical), 1550 nm: -14 dB to -65 dB (typical)
3 cm to 400 cm
Pulse widths (nominal)
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
Auto setting: 5 sec (typical)
Quick test setting: 2 sec (typical)
3, 10, 30, 100, 300, 1000,
3000, 10000, 20000 ns
Auto setting: 10 sec (typical)
Quick test setting: 5 sec (typical)
850 nm: 3, 5, 20, 40, 200 ns, 1300 nm: 3, 5, 20,
40, 200, 1000 ns, 1310/1550 nm: 3, 10, 30, 100,
300, 1000, 3000, 10000, 20000 ns
Auto setting:
MM - 5 sec (typical) SM – 10 sec (typical)
Quick test setting:
MM – 2 sec (typical) SM – 5 sec (typical)
Test time (per wavelength)
Best resolution setting: 2 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec
(max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Best resolution setting: 5 to 180 sec
FaultMap setting:
10 sec (typical), 180 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Best resolution setting:
MM – 2 to 180 sec SM – 5 to 180 sec
FaultMap setting:
MM – 2 sec (typical) MM – 180 sec (max)
SM – 10 sec (typical) SM – 180 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
MM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
6. SNR=1 method, 3 minute averaging, widest pulse width. 7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
11.Does not include index of refraction error and does not include automatic event location error.
12. dB variation per 1 dB step.
13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.
http://www.elso.sk
6 of 9
riešenia na presné meranie
Additional Key specifications
FiberInspector probe specifications
Magnification
Light source
Power source
Field of View (FOV)
~ 200X with OptiFiber Pro Display
Blue LED
TFS mainframe
Horizontal: 425 µm, Vertical: 320 μm
Minimum detectable particle size
Dimensions
Weight
Temperature range
0.5 µm
Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
200 g
Operating: 32°F to 122°F (0 °C to +50 °C), Storage: -4°F to +158°F (-20°C to +70°C)
VFL specifications
On/Off control
Output power
Operating wavelength
Spectral width (RMS)
Output modes
Mechanical switch and a button on the touch screen
316 µW (-5 dBm) ≤ peak power ≤ 1.0 mW (0 dBm)
650 nm nominal
±3 nm
Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2
For complete kit configurations, please visit www.flukenetworks.com/orderopro
Technical specifications
General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery
Battery life
Lithium ion battery pack, 7.2 volts
8 hr Auto OTDR operation, dual wavelength no video probe connected, 150 m of fiber
Charge Time
Tester off
Tester on
4 hours to charge from 10% to 90% capacity
6 hours to charge from 10% to 90% capacity with the tester on
Environmental specifications
Operating temperature*
Non-operating temperature
Operating altitude
Storage altitude
-18ºC to 45ºC
-30ºC to 60ºC
4,000 m (13,123 ft), 3,200 m (10,500 ft) with AC adapter
12,000 m
EMC EN 61326-1
Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
http://www.elso.sk
7 of 9
riešenia na presné meranie
OptiFiber Pro ordering information
Model Description
OFP-100-M OptiFiber Pro Multimode OTDR kit
OFP-100-MI
OFP-100-S
OptiFiber Pro Multimode OTDR with inspection kit
OptiFiber Pro Singlemode OTDR kit
OFP-100-SI
OFP-100-Q
OFP-100-QI
OFP-MM
OFP-SM
OFP-QUAD
OFP-FI
OFPQI-MFP
OFPMI-MFP
OFPQI-CER
OFPQI-MFP-CER
Accessories
MMC-50-SCSC
MMC-50-SCLC
MMC-50-SCST
MMC-50-SCFC
MMC-50-SCE2K
MMC-62-SCSC
MMC-62-SCLC
MMC-62-SCST
MMC-62-SCFC
SMC-9-SCSC
SMC-9-SCLC
SMC-9-SCST
SMC-9-SCFC
SMC-9-SCE2KAPC
PA-SC
PA-ST
PA-FC
VERSIV-TSET
VERSIV-BATTERY
VERSIV-ACUN
VERSIV-STRP
VERSIV-STND
OptiFiber Pro Singlemode OTDR with inspection kit
OptiFiber Pro QUAD OTDR kit
OptiFiber Pro QUAD OTDR with inspection kit
OptiFiber Pro Multimode OTDR module
OptiFiber Pro Singlemode OTDR module
OptiFiber Pro QUAD OTDR module
DI-1000 Inspector with selective bulkhead and video probe tip set FI1000-TIP-KIT
Data Center Fiber (MM/SM) Troubleshooting Kit
Data Center Fiber (MM) Troubleshooting Kit
Enterprise Fiber Cabling Certification Kit
Enterprise Fiber Cabling Kit Certification and Troubleshooting Kit
Description
Multimode launch cable 50µm SC/SC
Multimode launch cable 50µm SC/LC
Multimode launch cable 50µm SC/ST
Multimode launch cable 50µm SC/FC
Multimode launch cable 50µm SC/E2K
Multimode launch cable 62.5µm SC/SC
Multimode launch cable 62.5µm SC/LC
Multimode launch cable 62.5µm SC/ST
Multimode launch cable 62.5µm SC/FC
Singlemode launch cable 9µm SC/SC
Singlemode launch cable 9µm SC/LC
Singlemode launch cable 9µm SC/ST
Singlemode launch cable 9µm SC/FC
Singlemode launch cable 9µm SC/E200 APC
OTDR source port interchangeable SC adapter
OTDR source port interchangeable ST adaptert
OTDR source port interchangeable FC adapter
VERSIV Headphones
VERSIV Battery
VERSIV Charge
VERSIV Strap kit
VERSIV Demo Stand http://www.elso.sk
8 of 9
riešenia na presné meranie
FiberInspector probe models and accessories
Model Description
FI1000 DI-1000 FiberInspector USB video probe for OptiFiber Pro
FI1000-SCFC-TIP
FI1000-TIP-KIT
SC and FC bulkhead video probe tip
LC, FC/SC Bulkhead, 1.25 and 2.5 mm universal tips in a box
FI1000-LC-TIP
FI1000-ST-TIP
FI1000-MU-TIP
FI1000-E2KAPC-TIP
FI1000-SCAPC-TIP
FI1000-E2K-TIP
FI1000-LCAPC-TIP
FI1000-2.5-UTIP
FI1000-1.25-UTIP
FI1000-2.5APC-UTIP
FI1000-MPO-UTIP
FI1000-MPOAPC-UTIP
FI1000-1.25APC-UTIP
LC bulkhead video probe tip
ST bulkhead video probe tip
MU bulkhead video probe tip
E2000/APC bulkhead video probe tip
SC/APC bulkhead video probe tip
E2000 bulkhead video probe tip
LC/APC bulkhead video probe tip
2.5mm universal video probe tip for patch cords
1.25mm universal video probe tip for patch cords
2.5mm APC universal video probe tip for patch cords
MPO probe tip and translator knob for patch cords and bulkheads
MPO/APC probe tip and translator knob for patch cords and bulkheads
1.25mm APC universal video probe tip for patch cords
Gold Support
Model
GLD-OFP-100-Q
GLD3-OFP-100-Q
GLD-OFP-100-QI
GLD3-OFP-100-QI
GLD-OFP-100-MS
GLD3-OFP-100-MS
GLD-OFP-100-MS/SI
GLD3-OFP-100-MS/SI
GLD-OFPQI-MFP
GLD3-OFPQI-CER
GLD-OFPQI-MFP-CER
Description
1 year of Gold support coverage for OptiFiber Pro OTDR - Model: OFP-100-Q
3 year of Gold support coverage for OptiFiber Pro OTDR - Model: OFP-100-Q
1 year of Gold support coverage for OptiFiber Pro Quad OTDR kit
3 year of Gold support coverage for OptiFiber Pro Quad OTDR kit - Model: OFP-100-QI
1 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR kit - Models: OFP-100-M OR OFP-100-S
3 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR kit - Models: OFP-100-M OR OFP-100-S
1 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR with inspection kit - Models: OFP-100-MI OR
OFP-100-SI
1 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR with inspection kit - Models: OFP-100-MI OR
OFP-100-SI
1 year of Gold support coverage for OptiFiber Pro OTDR and MultiFiber Pro
1 year of Gold support coverage for OptiFiber Pro OTDR and DTX CertiFiber
1 year of Gold support coverage for OptiFiber Pro OTDR, DTX CertiFiber and MultiFiber Pro
For a complete listing of OptiFiber Pro models and accessories, visit www.flukenetworks.com/OPRO .
Fluke Networks operates in more than 50 countries worldwide.
To find your local office contact details, go to www.flukenetworks.com/contact
.
© 2013 Fluke Corporation. Rev: 06/09/2013 11:33 pm (Literature Id: 4137124) http://www.elso.sk
9 of 9
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project