Datasheet: OptiFiber® Pro OTDR

Accelerates enterprise fiber troubleshooting and certification.

The OptiFiber Pro OTDR is the Tier 2

(extended) fiber certification solution and part of the Versiv™ Cabling Certification product family. The Versiv line also includes copper certification, OLTS and Wi-

Fi analysis modules. Versiv is designed around the revolutionary ProjX™ management system and Taptive™ user interface. ProjX tracks jobs to ensure they're done correctly the first time, thus reducing rework. With the intuitive Taptive user interface, instrument set-up and operation are so simple, even operators with limited cabling skills can successfully test and troubleshoot a system. Analysis of measurement data and professional test reports are easy with the familiar

LinkWare™ management software.

Get ready to overachieve.

Designed for enterprise fiber

As enterprise networks and datacenter architectures evolve, IT infrastructure administrators demand better OTDR technology to maintain fiber network performance. Many OTDRs (Optical

Time Domain Reflectometers) used for fiber troubleshooting are designed for carriers and contain cumbersome and complicated features that enterprise users don’t need. Few OTDRs are built with features and usability for enterprise network engineers, SAN designers and cable installers.

As enterprises consume more storage resources and adopt higher bandwidth (40G, 100G) datacenter architectures, the resilience of the cabling infrastructure becomes highly dependent upon maintenance tools to ensure fiber reliability. OptiFiber Pro is the industry’s first purposebuilt OTDR that meets the unique challenges of an enterprise fiber infrastructure. With its simple

Taptive user interface and powerful feature set, the OptiFiber Pro turns anyone into an efficient and expert premise fiber troubleshooter or installer.

Unique features:

Versiv enables users to accomplish more than ever with a cable tester, accelerating every step of the testing process

ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.

Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of of technicians of all skill levels.

LinkWare management software provides unmatched analysis of test results and professional test reports

Performance:

Test times as short as two seconds in Quick Test mode

Quickly test datacenter fiber with pre-programmed settings

Troubleshoot datacenter fiber links with short patch cables and many connectors because of ultra short dead zones

Easily characterize all connectors, splices and areas of high loss with graphical

EventMap™ view

ProjX management system increases return on investment by enabling OTDR project sharing among users and different jobs

Reduce network downtime by quickly and precisely identifying faults on all fiber types

Built-in Visual Fault Locator (VFL) easily identifies damaged fibers.

http://www.elso.sk

1 of 9

riešenia na presné meranie

Standards:

Full OTDR capability that certifies fiber performance based on industry standards or customer specifications

Complaint with ISO and TIA standards

Unique certification with flexibility and efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With ProjX management system, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

Advantages:

Powerful ProjX management system facilitates OTDR sharing with clear job assignment for each operator

Easy monitoring of job progress with pass/fail results

Built-in Visual Fault Locator (VFL) to facilitate troubleshooting

On-screen report generation and upload to LinkWare™ application

Taptive user interface

Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro has the

Taptive user interface which combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.

View traces Pinch and zoom in for trace detail

Optimized for the datacenter

Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead-zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.

Advantages:

Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links

Datacenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber

The EventMap feature depicts fiber events in a way that requires no trace analysis expertise http://www.elso.sk

2 of 9

riešenia na presné meranie

Extremely short event and attenuation dead zone

The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.5 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area network environments.

Extremely short event and attenuation dead zone

Two second trace per wavelength

Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap event, Table or Trace. The end result is less time spent testing and more time performing other tasks.

DataCenter OTDR mode

DataCenter OTDR™ mode

With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine tuning as needed in legacy OTDRs.

DataCenter OTDR mode automatically detects OTDR parameters – end-detection algorithms, pulse widths – without getting confused by the short links or number of connectors.

http://www.elso.sk

3 of 9

riešenia na presné meranie

Graphical EventMap™ view

To eliminate the learning curve associated with reading an OTDR trace, OptiFiber Pro’s advance logic automatically interprets the information to create a detailed and graphical map of events that includes connectors, splices and anomalies. To accommodate different preferences, users can easily switch between the EventMap, the Event Table and the Trace for test details. Any faulty events will be highlighted with RED icons to facilitate quick troubleshooting.

On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

Graphical EventMap™ view - PASS Eventmap™ - FAIL. See Help icon for on screen corrective action.

Dynamic project and user profile management with ProjX management system

OptiFiber Pro enhances job efficiency by allowing the project manager to create and manage operator and job profiles per project. Defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

ProJX: Dynamic project and user profile management http://www.elso.sk

4 of 9

riešenia na presné meranie

FiberInspector™ probe

OptiFiber Pro’s video inspection system examines patch cords and patch panel bulkheads to avoid the number one cause of fiber link failure – contamination. Significant time is saved because the probe is inserted directly into the patch panel’s bulkhead to examine installed fiber terminations without disassembling the patch panel. Technicians assign a pass or fail grade to the fiber, can add a comment and save it for use in certification reports.

FiberInspector probe

LinkWare™ Management Software

With LinkWare management software, OptiFiber Pro users can easily access the ProjX management system data, generate reports and upgrade the software in their testers. Project managers have full capabilities to monitor workflow and consolidate test results. LinkWare stats, provides automated statistical reports. This application moves you above and beyond the page-per-link report to see your entire cabling infrastructure in one summary. It analyzes and transforms LinkWare test results into charts to reveal your cabling plant performance. The report even summarizes your entire cabling infrastructure in a compact, graphical format so it's easy to verify margins and spot anomalies. Previous versions of LinkWare are backwards compatible with new versions, so you can stay current and integrate tests from different testers into one-test report. Combine

OLTS Tier 1 (basic) and OTDR Tier 2 (extended) fiber certification results in a single report while allowing management of multiple jobs simultaneously. Users can provide the finishing touch by adding their company logo to the report and before offering to their customers for system acceptance. Keep your business tools simple. No matter which Fluke Networks cabling certification tester you use, LinkWare reports it all.

LinkWare Report

http://www.elso.sk

5 of 9

riešenia na presné meranie

Key OTDR specifications

Wavelengths

Compatible fiber types

Event dead zone 1

Attenuation dead zone 2

Dynamic range

3, 5, 6

Max distance range setting

Distance measurement range 4, 5, 7, 8, 9, 10

Reflectance range

Sample resolution

4, 5

Mutimode module

850 nm +/- 10 nm

1300 nm +35/-15 nm

50/125 µm

62.5/125 µm

 850 nm: 0.5 m (typical)

1300 nm: 0.7 m (typical)

850 nm: 2.5 m (typical)

1300 nm: 4.5 m (typical)

 850 nm: 28 dB (typical)

1300 nm: 30 dB (typical)

40 km

850 nm: 9 km

1300 nm: 35 km

850 nm: -14 dB to -57 dB (typical)

1300 nm: -14 dB to -62 dB (typical)

3 cm to 400 cm

Singlemode module

1310 nm +/- 25 nm

1550 nm +/- 30 nm

Singlemode

1310 nm: 0.6 m (typical)

1550 nm: 0.6 m (typical)

1310 nm: 3.6 m (typical)

1550 nm: 3.7 m (typical)

1310 nm: 32 dB (typical)

1550 nm: 30 dB (typical)

130 km;

1310 nm: 80 km

1550 nm: 130 km

1310 nm: -14 dB to -65 dB (typical)

1550 nm: -14 dB to -65 dB (typical)

3 cm to 400 cm

Quad module

850 nm +/- 10 nm, 1300 nm +35/-15 nm, 1310 nm

+/- 25 nm, 1550 nm +/- 30 nm

50/125 μm, 62.5/125 μm, Singlemode

850 nm: 0.5 m (typical), 1300 nm: 0.7 m (typical),

1310 nm: 0.6 m (typical), 1550 nm: 0.6 m (typical)

 850 nm: 2.5 m (typical), 1300 nm: 4.5 m (typical),

1310 nm: 3.6 m (typical), 1550 nm: 3.7 m (typical)

850 nm: 28 dB (typical), 1300 nm: 30 dB (typical),

1310 nm: 32 dB (typical), 1550 nm: 30 dB (typical)

MM: 40 km, SM: 130 km

850 nm: 9 km, 1300 nm: 35 km, 1310 nm: 80 km,

1550 nm: 130 km

850 nm: -14 dB to -57 dB (typical), 1300 nm: -14 dB to -62 dB (typical), 1310 nm: -14 dB to -65 dB

(typical), 1550 nm: -14 dB to -65 dB (typical)

3 cm to 400 cm

Pulse widths (nominal)

850 nm: 3, 5, 20, 40, 200 ns

1300 nm: 3, 5, 20, 40, 200, 1000 ns

Auto setting: 5 sec (typical)

Quick test setting: 2 sec (typical)

3, 10, 30, 100, 300, 1000,

3000, 10000, 20000 ns

Auto setting: 10 sec (typical)

Quick test setting: 5 sec (typical)

850 nm: 3, 5, 20, 40, 200 ns, 1300 nm: 3, 5, 20,

40, 200, 1000 ns, 1310/1550 nm: 3, 10, 30, 100,

300, 1000, 3000, 10000, 20000 ns

Auto setting:

MM - 5 sec (typical) SM – 10 sec (typical)

Quick test setting:

MM – 2 sec (typical) SM – 5 sec (typical)

Test time (per wavelength)

Best resolution setting: 2 to 180 sec

FaultMap setting:

2 sec (typical), 180 sec (max)

DataCenter OTDR setting:

1 sec (typical at 850 nm), 7 sec

(max)

Manual setting:

3, 5, 10, 20, 40, 60, 90, 120, 180 sec

Best resolution setting: 5 to 180 sec

FaultMap setting:

10 sec (typical), 180 sec (max)

DataCenter OTDR setting:

20 sec (typical), 40 sec (max)

Manual setting:

3, 5, 10, 20, 40, 60, 90, 120, 180 sec

Best resolution setting:

MM – 2 to 180 sec SM – 5 to 180 sec

FaultMap setting:

MM – 2 sec (typical) MM – 180 sec (max)

SM – 10 sec (typical) SM – 180 sec (max)

DataCenter OTDR setting:

MM – 1 sec (typical at 850 nm) MM – 7 sec (max)

SM – 20 sec (typical) SM – 40 sec (max)

Manual setting:

MM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.

2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.

3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.

4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.

5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.

6. SNR=1 method, 3 minute averaging, widest pulse width. 7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).

8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).

9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).

10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).

11.Does not include index of refraction error and does not include automatic event location error.

12. dB variation per 1 dB step.

13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.

http://www.elso.sk

6 of 9

riešenia na presné meranie

Additional Key specifications

FiberInspector probe specifications

Magnification

Light source

Power source

Field of View (FOV)

~ 200X with OptiFiber Pro Display

Blue LED

TFS mainframe

Horizontal: 425 µm, Vertical: 320 μm

Minimum detectable particle size

Dimensions

Weight

Temperature range

0.5 µm

Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip

200 g

Operating: 32°F to 122°F (0 °C to +50 °C), Storage: -4°F to +158°F (-20°C to +70°C)

VFL specifications

On/Off control

Output power

Operating wavelength

Spectral width (RMS)

Output modes

Mechanical switch and a button on the touch screen

316 µW (-5 dBm) ≤ peak power ≤ 1.0 mW (0 dBm)

650 nm nominal

±3 nm

Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)

Connector adapter 2.5 mm universal

Laser safety (classification) Class II CDRH Complies to EN 60825-2

For complete kit configurations, please visit www.flukenetworks.com/orderopro

Technical specifications

General specifications

Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)

Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)

Battery

Battery life

Lithium ion battery pack, 7.2 volts

8 hr Auto OTDR operation, dual wavelength no video probe connected, 150 m of fiber

Charge Time

Tester off

Tester on

4 hours to charge from 10% to 90% capacity

6 hours to charge from 10% to 90% capacity with the tester on

Environmental specifications

Operating temperature*

Non-operating temperature

Operating altitude

Storage altitude

-18ºC to 45ºC

-30ºC to 60ºC

4,000 m (13,123 ft), 3,200 m (10,500 ft) with AC adapter

12,000 m

EMC EN 61326-1

Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.

Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.

http://www.elso.sk

7 of 9

riešenia na presné meranie

OptiFiber Pro ordering information

Model Description

OFP-100-M OptiFiber Pro Multimode OTDR kit

OFP-100-MI

OFP-100-S

OptiFiber Pro Multimode OTDR with inspection kit

OptiFiber Pro Singlemode OTDR kit

OFP-100-SI

OFP-100-Q

OFP-100-QI

OFP-MM

OFP-SM

OFP-QUAD

OFP-FI

OFPQI-MFP

OFPMI-MFP

OFPQI-CER

OFPQI-MFP-CER

Accessories

MMC-50-SCSC

MMC-50-SCLC

MMC-50-SCST

MMC-50-SCFC

MMC-50-SCE2K

MMC-62-SCSC

MMC-62-SCLC

MMC-62-SCST

MMC-62-SCFC

SMC-9-SCSC

SMC-9-SCLC

SMC-9-SCST

SMC-9-SCFC

SMC-9-SCE2KAPC

PA-SC

PA-ST

PA-FC

VERSIV-TSET

VERSIV-BATTERY

VERSIV-ACUN

VERSIV-STRP

VERSIV-STND

OptiFiber Pro Singlemode OTDR with inspection kit

OptiFiber Pro QUAD OTDR kit

OptiFiber Pro QUAD OTDR with inspection kit

OptiFiber Pro Multimode OTDR module

OptiFiber Pro Singlemode OTDR module

OptiFiber Pro QUAD OTDR module

DI-1000 Inspector with selective bulkhead and video probe tip set FI1000-TIP-KIT

Data Center Fiber (MM/SM) Troubleshooting Kit

Data Center Fiber (MM) Troubleshooting Kit

Enterprise Fiber Cabling Certification Kit

Enterprise Fiber Cabling Kit Certification and Troubleshooting Kit

Description

Multimode launch cable 50µm SC/SC

Multimode launch cable 50µm SC/LC

Multimode launch cable 50µm SC/ST

Multimode launch cable 50µm SC/FC

Multimode launch cable 50µm SC/E2K

Multimode launch cable 62.5µm SC/SC

Multimode launch cable 62.5µm SC/LC

Multimode launch cable 62.5µm SC/ST

Multimode launch cable 62.5µm SC/FC

Singlemode launch cable 9µm SC/SC

Singlemode launch cable 9µm SC/LC

Singlemode launch cable 9µm SC/ST

Singlemode launch cable 9µm SC/FC

Singlemode launch cable 9µm SC/E200 APC

OTDR source port interchangeable SC adapter

OTDR source port interchangeable ST adaptert

OTDR source port interchangeable FC adapter

VERSIV Headphones

VERSIV Battery

VERSIV Charge

VERSIV Strap kit

VERSIV Demo Stand http://www.elso.sk

8 of 9

riešenia na presné meranie

FiberInspector probe models and accessories

Model Description

FI1000 DI-1000 FiberInspector USB video probe for OptiFiber Pro

FI1000-SCFC-TIP

FI1000-TIP-KIT

SC and FC bulkhead video probe tip

LC, FC/SC Bulkhead, 1.25 and 2.5 mm universal tips in a box

FI1000-LC-TIP

FI1000-ST-TIP

FI1000-MU-TIP

FI1000-E2KAPC-TIP

FI1000-SCAPC-TIP

FI1000-E2K-TIP

FI1000-LCAPC-TIP

FI1000-2.5-UTIP

FI1000-1.25-UTIP

FI1000-2.5APC-UTIP

FI1000-MPO-UTIP

FI1000-MPOAPC-UTIP

FI1000-1.25APC-UTIP

LC bulkhead video probe tip

ST bulkhead video probe tip

MU bulkhead video probe tip

E2000/APC bulkhead video probe tip

SC/APC bulkhead video probe tip

E2000 bulkhead video probe tip

LC/APC bulkhead video probe tip

2.5mm universal video probe tip for patch cords

1.25mm universal video probe tip for patch cords

2.5mm APC universal video probe tip for patch cords

MPO probe tip and translator knob for patch cords and bulkheads

MPO/APC probe tip and translator knob for patch cords and bulkheads

1.25mm APC universal video probe tip for patch cords

Gold Support

Model

GLD-OFP-100-Q

GLD3-OFP-100-Q

GLD-OFP-100-QI

GLD3-OFP-100-QI

GLD-OFP-100-MS

GLD3-OFP-100-MS

GLD-OFP-100-MS/SI

GLD3-OFP-100-MS/SI

GLD-OFPQI-MFP

GLD3-OFPQI-CER

GLD-OFPQI-MFP-CER

Description

1 year of Gold support coverage for OptiFiber Pro OTDR - Model: OFP-100-Q

3 year of Gold support coverage for OptiFiber Pro OTDR - Model: OFP-100-Q

1 year of Gold support coverage for OptiFiber Pro Quad OTDR kit

3 year of Gold support coverage for OptiFiber Pro Quad OTDR kit - Model: OFP-100-QI

1 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR kit - Models: OFP-100-M OR OFP-100-S

3 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR kit - Models: OFP-100-M OR OFP-100-S

1 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR with inspection kit - Models: OFP-100-MI OR

OFP-100-SI

1 year of Gold support coverage for OptiFiber Pro Multimode or Singlemode OTDR with inspection kit - Models: OFP-100-MI OR

OFP-100-SI

1 year of Gold support coverage for OptiFiber Pro OTDR and MultiFiber Pro

1 year of Gold support coverage for OptiFiber Pro OTDR and DTX CertiFiber

1 year of Gold support coverage for OptiFiber Pro OTDR, DTX CertiFiber and MultiFiber Pro

For a complete listing of OptiFiber Pro models and accessories, visit www.flukenetworks.com/OPRO .

Fluke Networks operates in more than 50 countries worldwide.

To find your local office contact details, go to www.flukenetworks.com/contact

.

© 2013 Fluke Corporation. Rev: 06/09/2013 11:33 pm (Literature Id: 4137124) http://www.elso.sk

9 of 9

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement