advertisement
QuickScan
® i
QD2100 Barcode Imager
Product Reference Guide
Configuring the Interface
KEYBOARD
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding
Select KBD-AT
Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard
Select KBD-AT-NK
FEATURES
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key
Select KBD-AT-ALT
Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard
Set KEYBOARD
WEDGE
Interface
Features
Select KBD-AT-ALT-NK
PC/XT w/Standard Key Encoding
Select KBD-XT
Keyboard Wedge for IBM Terminal 3153
Select KBD-IBM-3153
Product Reference Guide 13
Chapter 5
RS-232 ONLY Interface
Introduction
Use the programming barcodes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings
which apply to both the RS-232 and USB interfaces are available in Chapter 6, RS-232/
RS-232 Standard Factory Settings
Reference
for a listing of standard factory settings.
Baud Rate
Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.
ENTER/EXIT PROGRAMMING MODE
Baud Rate = 1200
Baud Rate = 2400
Baud Rate = 4800
Product Reference Guide 41
RS-232 ONLY Interface
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Baud Rate = 9600
Baud Rate = 19,200
Baud Rate = 38,400
Baud Rate = 57,600
Baud Rate = 115,200
42 QuickScan® QD2100
Data Bits
Data Bits
This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit
ASCII protocol for sending and receiving data.
ENTER/EXIT PROGRAMMING MODE
7 Data Bits
DEFAULT
8 Data Bits
Product Reference Guide 43
RS-232 ONLY Interface
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
1 Stop Bit
2 Stop Bits
44 QuickScan® QD2100
Parity
Parity
This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
• Select None when no parity bit is required.
• Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
• Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Parity = None
Parity = Even
Parity = Odd
Product Reference Guide 45
RS-232 ONLY Interface
Handshaking Control
The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options:
• RTS — RTS is asserted during transmissions. CTS is ignored.
• RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions.
• RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and
XOFF gate transmissions.
• RTS On/CTS — RTS is always asserted. CTS gates transmissions.
• RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Handshaking Control = RTS
Handshaking Control = RTS/CTS
Handshaking Control = RTS/XON/XOFF
Handshaking Control = RTS On/CTS
46
Handshaking Control = RTS/CTS Scan Control
QuickScan® QD2100
Chapter 6
RS-232/USB-Com Interfaces
Introduction
The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.
Standard Factory Settings
Reference
for a listing of standard factory settings.
Product Reference Guide 47
RS-232/USB-Com Interfaces
Intercharacter Delay
This parameter specifies the intercharacter de lay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT INTERCHARACTER DELAY SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 7 for some examples of how to set this feature.
Table 7. Intercharacter Delay Setting Examples
150ms
EXAMPLES
600ms 850ms
STEP
1
2
ACTION
Desired Setting
Divide by 10 (and pad with leading zeroes to yield two-digits)
3
4
50ms
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT INTERCHARACTER DELAY SETTING
5
6
Scan Two Characters From
‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
15
‘5’ and ‘0’
60
0’ and ‘0’
85
‘8’ and ‘5’
48 QuickScan® QD2100
Intercharacter Delay
ENTER/EXIT PROGRAMMING MODE
Intercharacter Delay = No Delay
Select Intercharacter Delay Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 00 = No Intercharacter Delay
CANCEL
Product Reference Guide 49
RS-232/USB-Com Interfaces
Beep On ASCII BEL
When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
ENTER/EXIT PROGRAMMING MODE
Beep On ASCII BEL = Disable
DEFAULT
Beep On ASCII BEL = Enable
Beep On Not on File
This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.
Beep On Not On File = Disable
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Beep On Not On File = Enable
50 QuickScan® QD2100
ACK NAK Options
ACK NAK Options
This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
Options are:
• Disable
• Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent.
• Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command.
• Enable for label transmission and host-command acknowledge
DEFAULT
ENTER/EXIT PROGRAMMING MODE
ACK/NAK Protocol = Disable ACK/NAK
ACK/NAK Protocol = Enable for label transmission
ACK/NAK Protocol = Enable for host-command acknowledge
ACK/NAK Protocol = Enable for label transmission and host-command acknowledge
Product Reference Guide 51
RS-232/USB-Com Interfaces
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option Data Bits
has been set as 7
Data Bits.
NOTE
To set this feature:
1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in
, that represent the desired character/value in step 1
above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 8 for some examples of how to set this feature.
Table 8. ACK Character Setting Examples
STEP
1
2
3
4
ACTION
Desired Character/Value
Hex equivalent
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK CHARACTER SETTING
ACK
0x06
5
6
Scan Two Characters From
‘0’ and ‘6’
Scan ENTER/EXIT PROGRAMMING MODE
$
0x24
‘2’ and ‘4’
EXAMPLES
@
0x40
‘4’ and ‘0’
>
0x3E
‘3’ AND ‘E’
52 QuickScan® QD2100
ACK Character — cont.
ENTER/EXIT PROGRAMMING MODE
Select ACK Character Setting
DEFAULT 0x06 ‘ACK’ Character
ACK NAK Options
Product Reference Guide 53
RS-232/USB-Com Interfaces
NAK Character
This setting specifies an ASCII character or hex value to be used as the NAK character.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option Data Bits
has been set as 7
Data Bits.
NOTE
To set this feature:
1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT NAK CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in
, that represent the desired character/value in step 1
above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 9 for some examples of how to set this feature.
Table 9. NAK Character Setting Examples
STEP
1
2
3
4
ACTION
Desired Character/Value
Hex equivalent
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK CHARACTER SETTING
NAK
0x15
5
6
Scan Two Characters From
‘1’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
$
0x24
‘2’ and ‘4’
EXAMPLES
@
0x40
‘4’ and ‘0’
>
0x3E
‘3’ AND ‘E’
54 QuickScan® QD2100
NAK Character — cont.
ENTER/EXIT PROGRAMMING MODE
Select NAK Character Setting
DEFAULT 0x15 ‘NAK’ Character
ACK NAK Options
Product Reference Guide 55
RS-232/USB-Com Interfaces
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to
15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 10 for some examples of how to set this feature.
STEP
1
2
3
4
Desired Setting
Divide by 200
ACTION
200ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
5
7
Table 10. ACK NAK Timeout Value Setting Examples
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
EXAMPLES
1,000ms (1 sec.) 5200ms (5.2 sec.)
05 26
‘0’ and ‘5’ ‘2’ and ‘6’
15,000ms (1 sec.)
75
‘7’ and ‘5’
56 QuickScan® QD2100
ACK NAK Timeout Value — cont.
ENTER/EXIT PROGRAMMING MODE
Select ACK NAK Timeout Value Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 01 ACK NAK Timeout value is 200ms
ACK NAK Options
Product Reference Guide 57
RS-232/USB-Com Interfaces
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005,
20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in Appendix E, Keypad , that repre-
sent the number which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 11 for some examples of how to set this feature.
Table 11. ACK NAK Retry Count Setting Examples
EXAMPLES
2
3
4
STEP
1
ACTION
Desired Setting
Pad with leading zero(es)
Disable Retry
Count
000
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK NAK RETRY COUNT SETTING
5
6
Scan Three Characters From
‘0’, ‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
3 Retries
003
‘0’, ‘0’ and ‘3’
54 Retries
054
‘0’, ‘5’ and ‘4’
Unlimited Retries
255
‘2’, ‘5’ and ‘5’
58 QuickScan® QD2100
ACK NAK Retry Count — cont.
ENTER/EXIT PROGRAMMING MODE
Select ACK NAK Retry Count Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 003 = 3 Retries
CANCEL
ACK NAK Options
Product Reference Guide 59
RS-232/USB-Com Interfaces
ACK NAK Error Handling
This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
Options are:
• Ignore errors detected
• Process error as valid ACK character
• Process error as valid NAK character
DEFAULT
ENTER/EXIT PROGRAMMING MODE
ACK NAK Error Handling = Ignore Errors Detected
ACK NAK Error Handling = Process Error as Valid ACK Character
ACK NAK Error Handling = Process Error as
Valid NAK Character
60 QuickScan® QD2100
Indicate Transmission Failure
Indicate Transmission Failure
This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.
ENTER/EXIT PROGRAMMING MODE
Indicate Transmission Failure = Disable Indication
DEFAULT
Indicate Transmission Failure = Enable Indication
Product Reference Guide 61
RS-232/USB-Com Interfaces
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option Data Bits
has been set as 7
Data Bits.
NOTE
2
3
4
STEP
1
5
6
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the the Disable
Character is not used (not available).
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E,
, that represent the desired character/value in step 1
above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 12 for some examples of how to set this feature.
Table 12. Disable Character Setting Examples
ACTION EXAMPLES
Desired character/value ‘d’ ‘}’ ‘D’
0x44
Disable Command
Not Used
0xFF Hex equivalent
Scan ENTER/EXIT PROGRAMMING MODE
0x64
Scan SELECT DISABLE CHARACTER VALUE SETTING
Scan Two Characters From
‘6’ and ‘4’
Scan ENTER/EXIT PROGRAMMING MODE
0x7D
‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ AND ‘F’
62 QuickScan® QD2100
ENTER/EXIT PROGRAMMING MODE
Select Disable Character Setting
DEFAULT 0x44 = Disable Character is ‘D’
Disable Character
Product Reference Guide 63
RS-232/USB-Com Interfaces
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option Data Bits
has been set as 7
Data Bits.
NOTE
2
3
4
STEP
1
5
6
To set this feature:
Determine the desired character or value. A setting of 0xFF indicates the the Enable
Character is not used (not available).
1. Determine the desired character or value.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in
, that represent the desired character/value in step 2
above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 13 for some examples of how to set this feature.
Table 13. Enable Character Setting Examples
ACTION EXAMPLES
Desired character/value ‘e’ ‘}’ ‘E’
0x45
Enable Command
Not Used
0xFF Hex equivalent 0x65
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT DISABLE CHARACTER VALUE SETTING
Scan Two Characters From
‘6’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
0x7D
‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’
64 QuickScan® QD2100
ENTER/EXIT PROGRAMMING MODE
Select Enable Character Setting
DEFAULT 0x45 = Enable Character is ‘E’
Enable Character
Product Reference Guide 65
RS-232/USB-Com Interfaces
NOTES
66 QuickScan® QD2100
Chapter 7
Keyboard Interface
Introduction
Use the programming barcodes in this chapter to select options for USB Keyboard and
Wedge Interfaces.
Standard Factory Settings
Reference
for a listing of standard factory settings.
Scancode Tables
Information about control character emulation which applies to keyboard interfaces is
listed in Appendix F, Scancode Tables
.
Product Reference Guide 67
Keyboard Interface
Country Mode
This feature specifies the country/language supported by the keyboard.
Only the following interfaces support ALL Country Modes.
• USB Keyboard (without alternate key encoding)
• AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding
• Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard
• AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 without Alternate Key
• Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard
All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Country Mode = U.S.
Country Mode = Belgium
Country Mode = Croatia
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Britain
Supports only the interfaces listed in theCountry Mode feature description.
68
Country Mode = Czechoslovakia
QuickScan® QD2100
Country Mode
Country Mode = Denmark
ENTER/EXIT PROGRAMMING MODE
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = France
Country Mode = Germany
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Hungary
Country Mode = Italy
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Japanese 106-key
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Norway
Product Reference Guide 69
Keyboard Interface
Country Mode = Poland
ENTER/EXIT PROGRAMMING MODE
Supports only the interfaces listed in theCountry Mode feature description.
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Portugal
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Romania
Supports only the interfaces listed in theCountry Mode feature description.
Country Mode = Slovakia
Country Mode = Spain
70
Country Mode = Switzerland
Country Mode = Sweden
Supports only the interfaces listed in theCountry Mode feature description.
QuickScan® QD2100
Caps Lock State
Caps Lock State
This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Caps Lock State = Caps Lock OFF
Caps Lock State = Caps Lock ON
Caps Lock State = AUTO Caps Lock Enable
Numlock
This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Numlock = Numlock key unchanged
Numlock = Numlock key toggled
Product Reference Guide 71
Keyboard Interface
Send Control Characters
This feature Specifies how the reader transmits ASCII control characters to the host. Ref-
erence Appendix F, Scancode Tables for more information about control characters.
Options are as follows:
Control Character 00 — Characters from 00 to 0x1F are sent as control character
Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Control Character 01 — Characters from 00 to 0x1F are sent as control character
Ctrl+Capital Key, special keys are located from 0x80 to 0xA1.
Control Character 02 — Special keys are located from 00 to 0x1F and characters from
0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage
1252 — see
Microsoft Windows Codepage 1252 on page 306
).
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Wedge Send Control Characters = 00
Wedge Send Control Characters = 01
Wedge Send Control Characters = 02
72 QuickScan® QD2100
Wedge Quiet Interval
Wedge Quiet Interval
This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments.
This feature applies ONLY to the Keyboard Wedge interface.
NOTE
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure to set the Wedge Quiet Interval. See
examples of how to set this feature.
Table 14. Timeout Setting Examples
STEP
1
2
ACTION
Desired Setting
Divide by 10 (and pad with leading zeroes)
3
4
10ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT WEDGE QUIET INTERVAL SETTING
5
6
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
150ms
EXAMPLES
600ms
15
‘1’ and ‘5’
60
‘6’ and ‘0’
850ms
85
‘8’ and ‘5’
Product Reference Guide 73
Keyboard Interface
ENTER/EXIT PROGRAMMING MODE
Select Wedge Quiet Interval Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 10 = Quiet Interval of 100 ms
CANCEL
74 QuickScan® QD2100
Intercharacter Delay
Intercharacter Delay
This parameter specifies the intercharacter de lay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
This feature applies ONLY to the Keyboard Wedge interface.
NOTE
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT INTERCHARACTER DELAY SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table 14
for some examples of how to set this feature.
Table 15. Intercharacter Delay Setting Examples
150ms
EXAMPLES
600ms 850ms
STEP
1
ACTION
Desired Setting
2
3
4
50ms
Divide by 10 (and pad with leading zeroes to yield two-digits)
Scan ENTER/EXIT PROGRAMMING MODE
05
5
Scan SELECT INTERCHARACTER DELAY SETTING
Scan Two Characters From
‘0’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE
15
‘1’ and ‘5’
60
‘6’ and ‘0’
85
‘8’ and ‘5’
Product Reference Guide 75
Keyboard Interface
ENTER/EXIT PROGRAMMING MODE
Intercharacter Delay = No Delay
Select Intercharacter Delay Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 00 = No Intercharacter Delay
CANCEL
76 QuickScan® QD2100
Intercode Delay
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 =
20, etc
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 16 for some examples of how to set this feature.
Table 16. Wedge Intercode Delay Examples
STEP
1
2
3
4
ACTION
Desired Setting
Pad with leading zero(es)
No Delay
00
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT INTERCODE DELAY SETTING
5
7
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
5 Seconds
05
EXAMPLES
60 Seconds
60
‘0’ and ‘5’ ‘6’ and ‘0’
99 Seconds
99
‘9’ AND ‘9’
Product Reference Guide 77
Keyboard Interface
ENTER/EXIT PROGRAMMING MODE
Set Intercode Delay
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 00 = No Wedge Intercode Delay
78 QuickScan® QD2100
USB Keyboard Speed
This option specifies the USB poll rate for a USB keyboard.
This feature applies ONLY to the USB Keyboard interface.
NOTE
USB Keyboard Speed
DEFAULT
ENTER/EXIT PROGRAMMING MODE
USB Keyboard Speed = 1ms
USB Keyboard Speed = 2ms
USB Keyboard Speed = 3ms
USB Keyboard Speed = 4ms
USB Keyboard Speed = 5ms
Product Reference Guide 79
Keyboard Interface
USB Keyboard Speed — continued
ENTER/EXIT PROGRAMMING MODE
USB Keyboard Speed = 6ms
USB Keyboard Speed = 7ms
USB Keyboard Speed = 8ms
USB Keyboard Speed = 9ms
USB Keyboard Speed = 10ms
80 QuickScan® QD2100
Chapter 8
USB-OEM Interface
Introduction
Feature settings for USB interfaces differ depending upon which host type the reader will
be connected with. Use the feature settings in this chapter and Chapter 9, IBM 46XX
Interface to specifically configure for the USB-OEM interface. Other USB interfaces are
included in the approprite chapter for their host type.
Standard Factory Settings
Reference
for a listing of standard factory settings.
Product Reference Guide 81
USB-OEM Interface
USB-OEM Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate.
Options are:
• Table Top Scanner
• Handheld Scanner
It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.
NOTE
ENTER/EXIT PROGRAMMING MODE
USB-OEM Device Usage = Table Top Scanner
DEFAULT
USB-OEM Device Usage = Handheld Scanner
82 QuickScan® QD2100
Chapter 9
IBM 46XX Interface
Introduction
Use the barcodes in this section to configure programmable features for available IBM
46XX interfaces.
IBM Standard Factory Settings
Reference
for a listing of standard factory settings.
Product Reference Guide 83
IBM 46XX Interface
46xx Number of Host Resets
Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The configurable range for this feature is 1 to 15 resets.
84
ENTER/EXIT PROGRAMMING MODE
46xx Number of Host Resets = 1
46xx Number of Host Resets = 2
46xx Number of Host Resets = 3
46xx Number of Host Resets = 4
46xx Number of Host Resets = 5
DEFAULT
46xx Number of Host Resets = 6
QuickScan® QD2100
46xx Number of Host Resets
46xx Number of Host Resets — cont.
ENTER/EXIT PROGRAMMING MODE
46xx Number of Host Resets = 7
46xx Number of Host Resets = 8
46xx Number of Host Resets = 9
46xx Number of Host Resets = 10
46xx Number of Host Resets = 11
46xx Number of Host Resets = 12
Product Reference Guide 85
IBM 46XX Interface
46xx Number of Host Resets — cont.
ENTER/EXIT PROGRAMMING MODE
46xx Number of Host Resets = 13
46xx Number of Host Resets = 14
46xx Number of Host Resets = 15
86 QuickScan® QD2100
Transmit Labels in Code 39 Format
Transmit Labels in Code 39 Format
This feature enable/disables translation to Code 39 before transmitting label data to an
IBM-46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39.
Options are:
IBM Standard Format — Send labels in standard IBM format.
Code 39 Format — Translate the following symbologies to Code 39:
• USB-OEM: Code128, Code 93, and Codabar
• IBM-Port 5B: Code 128, Code 93, and Codabar
• IBM-Port 9B: Code 93 and Codabar
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Transmit Labels in Code 39 Format = IBM Standard Format
Transmit Labels in Code 39 Format = Code 39 Format
Product Reference Guide 87
IBM 46XX Interface
NOTES
88 QuickScan® QD2100
Chapter 10
Data Editing
Data Editing Overview
It is not recommended to use these features with IBM interfaces.
CAUTION
When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary userdefined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string.
There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with
specific symbologies. Figure 3 shows the available elements you can add to a message
string:
Figure 3. Breakdown of a Message String
Label ID Transmission:
Enable this option to transmit the Label ID you configure for the scanned symbology.
OR...
Prefix Label ID AIM ID Bar Code Data Label ID Suffix
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data.
00 - 20 Characters (ASCII)
NOTE
Additional advanced editing is available. Contact Technical Support on page 3 for more information.
Product Reference Guide 89
Data Editing
Please Keep In Mind...
• Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
•
A prefix or suffix may be applied (reference the Symbologies chapter for these settings)
across all symbologies (set via the Global features in this chapter).
•
You can add any character from the ASCII Chart (from 00-FF) on the inside back cover
of this manual as a prefix, suffix or Label ID.
• Enter prefixes and suffixes in the order in which you want them to appear on the output.
Global Prefix/Suffix
Up to 20 ASCII characters may be added as a prefix (in a position before the barcode
data) and/or as a suffix (in a position following the barcode data) as indicated in Figure 4 .
Figure 4. Prefix and Suffix Positions
OR...
Prefix Label ID AIM ID Bar Code Data
00 - 20 Characters (ASCII)
AND
OR
Label ID Suffix
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
1. Determine which ASCII character(s) are to be added to scanned barcode data. In this example, we’ll add a dollar sign (‘$’) as a prefix.
2. Scan the ENTER/EXIT barcode.
3. Scan the SET GLOBAL PREFIX barcode.
4. Reference the ASCII Chart on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is
24. To enter this selection code, scan the ‘2’ and ‘4’ barcodes from
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT barcode to terminate the string.
90 QuickScan® QD2100
6. Scan the ENTER/EXIT barcode once again to exit Programming Mode.
7. The resulting message string would appear as follows:
Scanned barcode data:12345
Resulting message string output: $12345
Global Prefix/Suffix
This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. To configure this feature, scan the ENTER/EXIT barcode to place the unit in Programming Mode, then the “Set Global Prefix” or “Set Global Suffix,” barcode followed by the digits (in hex) from the Alphanumeric characters in
ters are selected, scan the ENTER/EXIT barcode to terminate the string. Reference the section,
Example: Setting a Prefix on page 90 , for more information. Exit program-
ming mode by scanning the ENTER/EXIT barcode once again.
ENTER/EXIT PROGRAMMING MODE
Set Global Prefix
Set Global Suffix
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT No Global Prefix
Global Suffix = 0x0D (CR)
CANCEL
Product Reference Guide 91
Data Editing
Global AIM ID
This feature enables/disables addition of AIM IDs for all symbology types.
NOTE
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows:
• A close brace character (ASCII ‘]’), followed by...
• A code character (see the table below), followed by...
• A modifier character (the modifier character is symbol dependent).
SYMBOLOGY CHAR SYMBOLOGY CHAR
UPC/EAN E a Code 128/GS1-128 C
Code 39 and
Code 32
A
GS1 DataBar Omnidirectional, GS1 DataBar
Expanded
Standard 2 of 5 e
Codabar
Interleaved 2 of 5
F
I ISBN
Code 93 a.
b.
G Code 11 H
UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs.
ISBN (X with a 0 modifier character)
S
X b
Figure 5. AIM ID
Prefix Label ID AIM ID Bar Code Data Label ID Suffix
92 QuickScan® QD2100
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Global AIM ID = Disable
Global AIM ID
Global AIM ID = Enable
Product Reference Guide 93
Data Editing
GS1-128 AIM ID
If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3.
AIM IDs for other symbologies can be enabled/disabled independently as well. Contact
Customer Support for assistance.
ENTER/EXIT PROGRAMMING MODE
GS1-128 AIM ID = Disable
DEFAULT
GS1-128 AIM ID = Enable
94 QuickScan® QD2100
Label ID
Label ID
A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set
(see
Label ID: Pre-loaded Sets on page 95
) or individually per symbology (see Label
ID: Set Individually Per Symbology on page 98 ). If you wish to program the reader to
always include an industry standard label identifier for ALL symbology types, see the pre-
vious feature Global AIM ID on page 92 .
Label ID: Pre-loaded Sets
The reader supports two pre-loaded sets of Label IDs.
Table 17 shows the default set and
alternate set.
When changing from one Label ID set to another, all other reader configuration settings, including the host interface type, will be erased and set to the standard factory defaults. Any customized configuration will be lost.
CAUTION
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Label ID Pre-loaded Set = Return to Default Set
Label ID Pre-loaded Set = Alternate Set
Product Reference Guide 95
Data Editing
CODABAR
CODE11
CODE128
CODE39
CODE4
CODE5
CODE93
GS1 DATABAR OMNIDIRECTIONAL
GS1 DATABAR EXPANDED
GS1 DATABAR LIMITED
DATALOGIC 2OF5
GS1-128
EAN13
EAN13 P2
EAN13 P5
EAN13 P8
EAN8
EAN8 P2
EAN8 P5
EAN8 P8
FOLLETT 2OF5
GTIN
GTIN2
GTIN5
GTIN8
I2OF5
ISBN
ISBT128
CODE32
Table 17. Label ID Pre-loaded Sets
Symbology Default Label ID set
ASCII character
%
CE
4 j
#
*
&
R4
RX
RL s f
I
G8 i
A
G2
G5
O
G
FF
FF
FF
FF
F
F
F
F
473200
473500
473800
690000
490000
660000
410000
460000
460000
464600
464600
464600
464600
4F0000
470000
260000
523400
525800
524C00
730000
000000
460000
460000
Hexidecimal value
250000
434500
230000
2A0000
340000
6A0000
Alternate Label ID set
@ f
X
$B
$C
$D
N
O
$A
K
*
A
J
M
#
B
L s k t v
U u
ASCII character
R b
4 j
T
V
244200
244300
244400
4E0000
400000
660000
580000
4D0000
230000
410000
4A0000
4B0000
2A0000
4F0000
244100
550000
750000
740000
760000
730000
6B0000
420000
4C0000
Hexidecimal value
520000
620000
540000
560000
340000
6A0000
96 QuickScan® QD2100
S25
UPCA
UPCA P2
UPCA P5
UPCA P8
UPCE
UPCE P2
UPCE P5
UPCE P8
Symbology Default Label ID set
E
E
A
E
E
A
A s
A
730000
410000
410000
410000
410000
450000
450000
450000
450000
Alternate Label ID set
H
I
Q
D
E
F
G
P
C
500000
430000
460000
470000
510000
440000
480000
490000
450000
Label ID
Product Reference Guide 97
Data Editing
Label ID: Set Individually Per Symbology
To configure a Label ID individually for a single symbology:
1. Scan the ENTER/EXIT barcode.
2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suf-
fix) by scanning the appropriate barcode in the section Label ID Control on page 100
.
for Label ID positioning options if multiple identification features are enabled.
3. Scan a barcode to select the symbology for which you wish to configure a custom Label
ID from the section
Label ID Symbology Selection, starting on page 101 .
4. Determine the desired character(s) (you may choose up to three) which will represent the
Label ID for the selected symbology.
5. Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent
hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D. Turn to
and scan the barcodes representing the hex characters determined. For the example given, the characters ‘3’ and ‘D’ would be scanned. More examples of Label ID settings are provided in
.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT barcode to exit Label ID entry.
7. Scan the ENTER/EXIT barcode once again to exit Programming Mode.
This completes the steps to configure a Label ID for a given symbology.
Figure 6. Label ID Position Options
Prefix Label ID Aim ID
OR
Bar Code Data Label ID Suffix
98 QuickScan® QD2100
Label ID
Table 18. Label ID Examples
STEP ACTION
1.
Scan the ENTER/EXIT barcode
2.
3.
4.
EXAMPLES
(Scanner enters Programming Mode)
Determine placement of the Label
ID characters BEFORE or AFTER with regard to scanned data using
Enable as Prefix Enable as Suffix Enable as Prefix
Scan the barcode selecting the symbology type you wish to designate label ID characters for
GS1 DataBar
Omnidirectional
Custom Label ID example (desired characters):
D B *
Code 39
= C 3
Interleaved 2 of 5
+
Enable as Suffix
Code 32
P H
5.
Find hex equivalents from the
ASCII table (inside back cover), then scan in these digits/ characters using the barcodes in the section:
Keypad, starting on page 291 . f you make a
mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
6.
Scan theENTER/EXIT barcode
7.
Scan the ENTER/EXIT barcode once again
44 42 2A 3D 43 33 2B
(Scanner exits Label ID entry)
(Scanner exits Programming Mode)
50 48
Result: DB*[barcode data] [barcode data]=C3 +[barcode data] [barcode data]PH
Product Reference Guide 99
Data Editing
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Label ID Transmission = Disable
Label ID Transmission = Enable as Prefix
Label ID Transmission = Enable as Suffix
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
100 QuickScan® QD2100
Label ID
Label ID Symbology Selection
This option selects the symbology for which a Label ID is to be configured. See
Label ID on page 95 for full instructions.
ENTER/EXIT PROGRAMMING MODE
Set UPC-A Label ID Character(s)
Set UPC-A/P2 Label ID Character(s)
Set UPC-A/P5 Label ID Character(s)
Set UPC-A/GS1-128 Label ID Character(s)
Set UPC-E Label ID Character(s)
Set UPC-E/P2 Label ID Character(s)
Product Reference Guide 101
Data Editing
Label ID Symbology Selection — continued
This option selects the symbology for which a Label ID is to be configured. See
Label ID on page 95 for full instructions.
ENTER/EXIT PROGRAMMING MODE
Set UPC-E/P5 Label ID Character(s)
Set UPC-E/GS1-128 Label ID Character(s)
Set EAN 13 Label ID Character(s)
Set EAN 13/P2 Label ID Character(s)
Set EAN 13/P5 Label ID Character(s)
Set EAN 13/GS1-128 Label ID Character(s)
102 QuickScan® QD2100
Label ID
Label ID Symbology Selection — continued
This option selects the symbology for which a Label ID is to be configured. See
Label ID on page 95 for full instructions.
ENTER/EXIT PROGRAMMING MODE
Set EAN 8 Label ID Character(s)
Set EAN 8/P2 Label ID Character(s)
Set EAN 8/P5 Label ID Character(s)
Set EAN 8/GS1-128 Label ID Character(s)
Set GTIN Label ID Character(s)
Set GTIN/P2 Label ID Character(s)
Product Reference Guide 103
Data Editing
Label ID Symbology Selection — continued
This option selects the symbology for which a Label ID is to be configured. See
Label ID on page 95 for full instructions.
ENTER/EXIT PROGRAMMING MODE
Set GTIN/P5 Label ID Character(s)
Set GTIN/GS1-128 Label ID Character(s)
Set GS1 DataBar Omnidirectional Label ID Character(s)
Set GS1 DataBar Expanded Label ID Character(s)
Set GS1 DataBar Limited Label ID Character(s)
Set Code 39 Label ID Character(s)
104 QuickScan® QD2100
Label ID
Label ID Symbology Selection — continued
This option selects the symbology for which a Label ID is to be configured. See
Label ID on page 95 for full instructions.
ENTER/EXIT PROGRAMMING MODE
Set Code 32 Label ID Character(s)
Set Code 128 Label ID Character(s)
Set Concatinated ISBT 128 Label ID Character(s)
Set GS1-128 Label ID Character(s)
Set Interleaved 2 of 5 Label ID Character(s)
Set Codabar Label ID Character(s)
Set Code 11 Label ID Character(s)
Product Reference Guide 105
Data Editing
Label ID Symbology Selection — continued
This option selects the symbology for which a Label ID is to be configured. See
Label ID on page 95 for full instructions.
ENTER/EXIT PROGRAMMING MODE
Set Standard 2 of 5 Label ID Character(s)
Set Code 4 Label ID Character(s)
Set Code 5 Label ID Character(s)
Set Follett 2 of 5 Label ID Character(s)
106 QuickScan® QD2100
Case Conversion
Case Conversion
This feature allows conversion of the case of all alphabetic characters to upper or lower case.
Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data.
NOTE
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Case Conversion = Disable (no case conversion)
Case Conversion = Convert to upper case
Case Conversion = Convert to lower case
Product Reference Guide 107
Data Editing
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following:
41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF.
With the label, AB12BA21, it would look as follows after the character conversion: BB22BB22.
The A characters were converted to B characters and the 1 characters were converted to
2 characters. Nothing is done with the last two character pairs, since they are all FF.
To set Character Conversion:
1. Scan the ENTER/EXIT barcode.
2. Scan the “Configure Character Conversion” barcode.
3. Determine the desired string. Sixteen positions must be determined as in the above example. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string.
4. Turn to
and scan the barcodes representing the hex characters determined in the previous step.
5. Scan the ENTER/EXIT barcode to exit Programming Mode.
If less than the expected string of 16 characters are selected, scan the ENTER/EXIT barcode twice to accept the selections and exit Programming Mode.
NOTE
108 QuickScan® QD2100
Character Conversion
Character Conversion — continued
ENTER/EXIT PROGRAMMING MODE
Configure Character Conversion
DEFAULT 0xFFFFFFFFFFFFFFFF
(No character conversion)
Product Reference Guide 109
Data Editing
NOTES
110 QuickScan® QD2100
Chapter 11
Symbologies
Introduction
The reader supports the following symbologies (barcode types). Options for each symbology are included in this chapter.
Symbologies
•
•
•
(JAN 13)
•
•
•
•
(JAN 8) •
•
•
•
•
•
•
•
•
•
•
•
•
Standard Factory Settings for Symbologies
Default settings are indicated at each feature/option with a green arrow. Also reference
Appendix B, Standard Defaults for a listing of the most widely used set of standard fac-
tory settings. That section also provides space to record any custom settings needed or implemented for your system.
Product Reference Guide 111
Symbologies
UPC-A
The following options apply to the UPC-A symbology.
UPC-A Enable/Disable
When disabled, the reader will not read UPC-A barcodes.
ENTER/EXIT PROGRAMMING MODE
UPC-A = Disable
DEFAULT
UPC-A = Enable
UPC-A Check Character Transmission
Enable this option to transmit the check character along with UPC-A barcode data.
ENTER/EXIT PROGRAMMING MODE
UPC-A Check Character Transmission = Don’t Send
DEFAULT
UPC-A Check Character Transmission = Send
112 QuickScan® QD2100
UPC-A
Expand UPC-A to EAN-13
Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
UPC-A to EAN-13 = Don’t Expand
UPC-A to EAN-13 = Expand
UPC-A Number System Character Transmission
This feature enables/disables transmission of the UPC-A number system character.
ENTER/EXIT PROGRAMMING MODE
UPC-A Number System Character = Transmit
Product Reference Guide
UPC-A Number System Character = Do not transmit
DEFAULT
113
Symbologies
In-Store Minimum Reads
This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read.
In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'.
In-Store Minimum Reads = 2
ENTER/EXIT PROGRAMMING MODE
In-Store Minimum Reads = 1
DEFAULT
In-Store Minimum Reads = 3
In-Store Minimum Reads = 4
114 QuickScan® QD2100
UPC-E
UPC-E
The following options apply to the UPC-E symbology.
UPC-E Enable/Disable
When disabled, the reader will not read UPC-E barcodes.
ENTER/EXIT PROGRAMMING MODE
UPC-E = Disable
DEFAULT
UPC-E = Enable
UPC-E Check Character Transmission
Enable this option to transmit the check character along with UPC-E barcode data.
ENTER/EXIT PROGRAMMING MODE
UPC-E Check Character Transmission = Send
Product Reference Guide
UPC-E Check Character Transmission = Don’t Send
DEFAULT
115
Symbologies
Expand UPC-E to EAN-13
Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
UPC-E to EAN-13 = Don’t Expand
UPC-E to EAN-13 = Expand
Expand UPC-E to UPC-A
Expands UPC-E data to the UPC-A data format.
116
DEFAULT
ENTER/EXIT PROGRAMMING MODE
UPC-E to UPC-A = Don’t Expand
UPC-E to UPC-A = Expand
QuickScan® QD2100
UPC-E Number System Character Transmission
This feature enables/disables transmission of the UPC-E system number character.
UPC-E
ENTER/EXIT PROGRAMMING MODE
UPC-E Number System Character = Do not transmit
DEFAULT
UPC-E Number System Character = Transmit
Product Reference Guide 117
Symbologies
UPC-E Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as good read..
UPC-E Minimum Reads = 2
ENTER/EXIT PROGRAMMING MODE
UPC-E Minimum Reads = 1
DEFAULT
UPC-E Minimum Reads = 3
UPC-E Minimum Reads = 4
118 QuickScan® QD2100
GTIN Formatting
GTIN Formatting
This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN
13 labels into the GTIN 14-character format.
If add-on information is present on the base label prior to the conversion taking place, the addon information will be appended to the converted GTIN label.
NOTE
DEFAULT
ENTER/EXIT PROGRAMMING MODE
GTIN Formatting = Disable
GTIN Formatting = Enable
Product Reference Guide 119
Symbologies
EAN 13
The following options apply to the EAN 13 (Jan 13) symbology.
EAN 13 Enable/Disable
When disabled, the reader will not read EAN 13/JAN 13 barcodes.
ENTER/EXIT PROGRAMMING MODE
EAN 13 = Disable
DEFAULT
EAN 13 = Enable
EAN 13 Check Character Transmission
Enable this option to transmit the check character along with EAN 13 barcode data.
ENTER/EXIT PROGRAMMING MODE
EAN 13 Check Character Transmission = Don’t Send
DEFAULT
EAN 13 Check Character Transmission = Send
120 QuickScan® QD2100
EAN 13
EAN-13 Flag 1 Character
Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label.
ENTER/EXIT PROGRAMMING MODE
EAN-13 Flag 1 Char= Don’t transmit
DEFAULT
EAN-13 Flag 1 Char= Transmit
Product Reference Guide 121
Symbologies
EAN-13 ISBN Conversion
This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
EAN-13 ISBN Conversion = Disable
EAN-13 ISBN Conversion = Convert to ISBN
122 QuickScan® QD2100
EAN 13
EAN 13 Minimum Reads
This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
EAN 13 Minimum Reads = 1
EAN 13 Minimum Reads = 2
EAN 13 Minimum Reads = 3
EAN 13 Minimum Reads = 4
Product Reference Guide 123
Symbologies
EAN 8
The following options apply to the EAN 8 (Jan 8) symbology.
EAN 8 Enable/Disable
When disabled, the reader will not read EAN 8/JAN 8 barcodes.
ENTER/EXIT PROGRAMMING MODE
EAN 8 = Disable
DEFAULT
EAN 8 = Enable
EAN 8 Check Character Transmission
Enable this option to transmit the check character along with EAN 8 barcode data.
ENTER/EXIT PROGRAMMING MODE
EAN 8 Check Character Transmission = Don’t Send
DEFAULT
EAN 8 Check Character Transmission = Send
124 QuickScan® QD2100
Expand EAN 8 to EAN 13
Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Expand EAN 8 to EAN 13 = Disable
EAN 8
Expand EAN 8 to EAN 13 = Enable
Product Reference Guide 125
Symbologies
EAN 8 Minimum Reads
This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read..
DEFAULT
ENTER/EXIT PROGRAMMING MODE
EAN 8 Minimum Reads = 1
EAN 8 Minimum Reads = 2
EAN 8 Minimum Reads = 3
EAN 8 Minimum Reads = 4
126 QuickScan® QD2100
UPC/EAN Global Settings
UPC/EAN Global Settings
This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description.
UPC/EAN Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
Product Reference Guide 127
Symbologies
UPC/EAN Global Settings — cont.
UPC/EAN Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
UPC/EAN Decoding Level = 1
DEFAULT
UPC/EAN Decoding Level = 2
UPC/EAN Decoding Level = 3
UPC/EAN Decoding Level = 4
UPC/EAN Decoding Level = 5
128 QuickScan® QD2100
UPC/EAN Global Settings
UPC/EAN Global Settings — cont.
UPC/EAN Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
UPC/EAN Correlation = Disable
UPC/EAN Correlation = Enable
Product Reference Guide 129
Symbologies
UPC/EAN Global Settings — cont.
UPC/EAN Price Weight Check
This feature enables/disables calculation and verification of price/weight check digits.
Options are
• Disabled
• Enable 4-digit price-weight check-digit calculation
• Enable 5-digit price-weight check-digit calculation
• Enable European 4-digit price-weight check-digit calculation
• Enable European 5-digit price-weight check-digit calculation
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Price Weight Check = Disabled
Price Weight Check = 4-digit price-weight check
Price Weight Check = 5-digit price-weight check
Price Weight Check = European 4-digit price-weight check
130
Price Weight Check = European 5-digit price-weight check
QuickScan® QD2100
UPC/EAN Global Settings
UPC/EAN Global Settings — cont.
UPC-A Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good read..
DEFAULT
ENTER/EXIT PROGRAMMING MODE
UPC-A Minimum Reads = 1
UPC-A Minimum Reads = 2
UPC-A Minimum Reads = 3
UPC-A Minimum Reads = 4
Product Reference Guide 131
Symbologies
Add-Ons
The following features apply to optional add-ons.
Contact Customer Support for advanced programming of optional and conditional add-ons.
NOTE
Optional Add-ons
The reader can be enabled to optionally read the following add-ons (supplementals):
• P2
• P5
• GS1-128
If a UPC/EAN base label and a an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
NOTE
Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings.
132
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Optional Add-Ons = Disable P2
Optional Add-Ons = Enable P2
DEFAULT
Optional Add-Ons = Disable P5
QuickScan® QD2100
Optional Add-ons — cont.
ENTER/EXIT PROGRAMMING MODE
Optional Add-Ons = Enable P5
DEFAULT
Optional Add-Ons = Disable GS1-128
Add-Ons
Optional Add-Ons = Enable GS1-128
Product Reference Guide 133
Symbologies
Optional Add-On Timer
This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see
ENTER/EXIT PROGRAMMING MODE
Optional Add-on Timer = 10ms
Optional Add-on Timer = 20ms
Optional Add-on Timer = 30ms
Optional Add-on Timer = 40ms
Optional Add-on Timer = 50ms
134 QuickScan® QD2100
Optional Add-On Timer — cont.
ENTER/EXIT PROGRAMMING MODE
Optional Add-on Timer = 60ms
DEFAULT
Optional Add-on Timer = 70ms
Add-Ons
Optional Add-on Timer = 100ms
Optional Add-on Timer = 120ms
Optional Add-on Timer = 140ms
Optional Add-on Timer = 160ms
Product Reference Guide 135
Symbologies
Optional Add-On Timer — cont.
ENTER/EXIT PROGRAMMING MODE
Optional Add-on Timer = 180ms
Optional Add-on Timer = 200ms
Optional Add-on Timer = 220ms
Optional Add-on Timer = 240ms
Optional Add-on Timer = 260ms
Optional Add-on Timer = 280ms
136
Optional Add-on Timer = 300ms
QuickScan® QD2100
Add-Ons
Optional GS1-128 Add-On Timer
This option sets the timer expiration value to read the additional part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of this type, see
Optional Add-On Timer on page 134 .
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Optional GS1-128 Add-On Timer = Disable
Optional GS1-128 Add-On Timer = 10ms
Optional GS1-128 Add-On Timer = 20ms
Optional GS1-128 Add-On Timer = 30ms
Optional GS1-128 Add-On Timer = 40ms
Optional GS1-128 Add-On Timer = 50ms
Product Reference Guide 137
Symbologies
Optional GS1-128 Add-On Timer — cont.
ENTER/EXIT PROGRAMMING MODE
Optional GS1-128 Add-On Timer = 60ms
Optional GS1-128 Add-On Timer = 70ms
Optional GS1-128 Add-On Timer = 100ms
Optional GS1-128 Add-On Timer = 120ms
Optional GS1-128 Add-On Timer = 140ms
Optional GS1-128 Add-On Timer = 160ms
138 QuickScan® QD2100
Optional GS1-128 Add-On Timer — cont.
ENTER/EXIT PROGRAMMING MODE
Optional GS1-128 Add-On Timer = 180ms
Add-Ons
Optional GS1-128 Add-On Timer = 200ms
Optional GS1-128 Add-On Timer = 220ms
Optional GS1-128 Add-On Timer = 240ms
Optional GS1-128 Add-On Timer = 260ms
Optional GS1-128 Add-On Timer = 280ms
Product Reference Guide
Optional GS1-128 Add-On Timer = 300ms
139
Symbologies
P2 Add-Ons Minimum Reads
This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base labe l.
ENTER/EXIT PROGRAMMING MODE
P2 Add-Ons Minimum Reads = 1
DEFAULT
P2 Add-Ons Minimum Reads = 2
P2 Add-Ons Minimum Reads = 3
P2 Add-Ons Minimum Reads = 4
140 QuickScan® QD2100
Add-Ons
P5 Add-Ons Minimum Reads
This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base labe l.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
P5 Add-Ons Minimum Reads = 1
P5 Add-Ons Minimum Reads = 2
P5 Add-Ons Minimum Reads = 3
P5 Add-Ons Minimum Reads = 4
Product Reference Guide 141
Symbologies
GS1-128 Add-Ons Minimum Reads
This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base labe l.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1-128 Add-Ons Minimum Reads = 1
GS1-128 Add-Ons Minimum Reads = 2
GS1-128 Add-Ons Minimum Reads = 3
GS1-128 Add-Ons Minimum Reads = 4
142 QuickScan® QD2100
GS1 DataBar Omnidirectional
GS1 DataBar Omnidirectional
The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology.
GS1 DataBar Omnidirectional Enable/Disable
When disabled, the reader will not read GS1 DataBar Omnidirectional barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar Omnidirectional = Disable
GS1 DataBar Omnidirectional = Enable
GS1 DataBar Omnidirectional GS1-128 Emulation
When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1-
128 label data format.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Omnidirectional GS1-128 Emulation = Disable
GS1 DataBar Omnidirectional GS1-128 Emulation = Enable
Product Reference Guide 143
Symbologies
GS1 DataBar Omnidirectional — cont.
GS1 DataBar Omnidirectional Minimum Reads
This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read .
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Omnidirectional Minimum Reads = 1
GS1 DataBar Omnidirectional Minimum Reads = 2
GS1 DataBar Omnidirectional Minimum Reads = 3
GS1 DataBar Omnidirectional Minimum Reads = 4
144 QuickScan® QD2100
GS1 DataBar Expanded
GS1 DataBar Expanded
The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology.
GS1 DataBar Expanded Enable/Disable
When disabled, the reader will not read GS1 DataBar Expanded barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar Expanded = Disable
GS1 DataBar Expanded = Enable
GS1 DataBar Expanded GS1-128 Emulation
When enabled, GS1 DataBar Expanded barcodes will be translated to the GS1-128 label data format.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Expanded GS1-128 Emulation = Disable
GS1 DataBar Expanded GS1-128 Emulation = Enable
Product Reference Guide 145
Symbologies
GS1 DataBar Expanded Minimum Reads
This feature specifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read .
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Expanded Minimum Reads = 1
GS1 DataBar Expanded Minimum Reads = 2
GS1 DataBar Expanded Minimum Reads = 3
GS1 DataBar Expanded Minimum Reads = 4
146 QuickScan® QD2100
GS1 DataBar Expanded
GS1 DataBar Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the
GS1 DataBar Expanded symbology.
Variable Length — For variable-length decoding, a minimum length may be set.
Fixed Length — For fixed-length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Expanded Length Control = Variable Length
GS1 DataBar Expanded Length Control = Fixed Length
Product Reference Guide 147
Symbologies
GS1 DataBar Expanded Set Length 1
This feature specifies one of the barcode lengths for
Control . Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in
Fixed Length Mode. Length includes the barcode’s data characters on-
ly.
The length can be set from 1 to 74 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 74). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT GS1 DataBar EXPANDED LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 19 for some examples of how to set this feature.
Table 19. GS1 DataBar Expanded Length 1 Setting Examples
STEP
1
ACTION
Desired Setting
2
3
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
Scan SELECT GS1 DataBar EXPANDED LENGTH 1SETTING
EXAMPLES
52 Characters
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘5’ and ‘2’
74 Characters
‘7’ AND ‘4’
148 QuickScan® QD2100
GS1 DataBar Expanded Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar Expanded Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 01 = Length 1 is 1 Character
CANCEL
GS1 DataBar Expanded
Product Reference Guide 149
Symbologies
GS1 DataBar Expanded Set Length 2
This feature specifies one of the barcode lengths for
Control . Length 2 is the maximum label length if in Variable Length Mode, or the sec-
ond fixed length if in
Fixed Length Mode. Length includes the barcode’s data characters
only.
The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 74). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 20 for some examples of how to set this feature.
Table 20. GS1 DataBar Expanded Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
00 (ignore second length)
Scan ENTER/EXIT PROGRAMMING MODE
3
07 Characters
Scan SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING
EXAMPLES
52 Characters
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘5’ and ‘2’
74 Characters
‘7’ and ‘4’
150 QuickScan® QD2100
GS1 DataBar Expanded Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar Expanded Set Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 74 = Length 2 is 74 Characters
GS1 DataBar Expanded
Product Reference Guide 151
Symbologies
GS1 DataBar Limited
The following options apply to the GS1 DataBar Limited (formerly RSS Limited) symbology.
GS1 DataBar Limited Enable/Disable
When disabled, the reader will not read GS1 DataBar Limited barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar Limited = Disable
GS1 DataBar Limited = Enable
GS1 DataBar Limited GS1-128 Emulation
When enabled, GS1 DataBar Limited barcodes will be translated to the GS1-128 label data format.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Limited GS1-128 Emulation = Disable
152
GS1 DataBar Limited GS1-128 Emulation = Enable
QuickScan® QD2100
GS1 DataBar Limited
GS1 DataBar Limited Minimum Reads
This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read .
ENTER/EXIT PROGRAMMING MODE
DEFAULT
GS1 DataBar Limited Minimum Reads = 1
GS1 DataBar Limited Minimum Reads = 2
GS1 DataBar Limited Minimum Reads = 3
GS1 DataBar Limited Minimum Reads = 4
Product Reference Guide 153
Symbologies
Code 39
The following options apply to the Code 39 symbology.
Code 39 Enable/Disable
When disabled, the reader will not read Code 39 barcodes.
ENTER/EXIT PROGRAMMING MODE
Code 39 = Disable
DEFAULT
Code 39 = Enable
154 QuickScan® QD2100
Code 39
Code 39 Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Code
39 check character. When disabled, any check character in the label is treated as a data character.
ENTER/EXIT PROGRAMMING MODE
Code 39 Check Character Calculation = Calculate Std Check
Code 39 Check Character Calculation = Don’t Calculate
DEFAULT
Code 39 Check Character Calculation = Calculate Mod 7 Check
Code 39 Check Character Calculation = Enable Italian Post Check
Code 39 Check Character Calculation = Enable Daimler
Chrysler Check
Product Reference Guide 155
Symbologies
Code 39 Check Character Transmission
Enable this option to transmit the check character along with Code 39 barcode data.
ENTER/EXIT PROGRAMMING MODE
Code 39 Check Character Transmission = Don’t Send
DEFAULT
Code 39 Check Character Transmission = Send
Code 39 Start/Stop Character Transmission
Enable this option to enable/disable transmission of Code 39 start and stop characters.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 39 Start/Stop Character Transmission = Don’t Transmit
Code 39 Start/Stop Character Transmission = Transmit
156 QuickScan® QD2100
Code 39
Code 39 Full ASCII
In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code
39 full-ASCII characters.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 39 Full ASCII = Disable
Code 39 Full ASCII = Enable
Product Reference Guide 157
Symbologies
Code 39 Quiet Zones
This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MODE
Code 39 Quiet Zones = Quiet Zone on one side
Code 39 Quiet Zones = Quiet Zones on two sides
DEFAULT
Code 39 Quiet Zones = Auto
Code 39 Quiet Zones = Virtual Quiet Zones on two sides
158 QuickScan® QD2100
Code 39
Code 39 Minimum Reads
This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read..
Code 39 Minimum Reads = 2
ENTER/EXIT PROGRAMMING MODE
Code 39 Minimum Reads = 1
DEFAULT
Code 39 Minimum Reads = 3
Code 39 Minimum Reads = 4
Product Reference Guide 159
Symbologies
Code 39 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level .
NOTE
This configuration item applies to Code 39 and Code 32.
160 QuickScan® QD2100
Code 39 Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
Code 39 Decoding Level = 1
Code 39 Decoding Level = 2
DEFAULT
Code 39 Decoding Level = 3
Code 39
Code 39 Decoding Level = 4
Code 39 Decoding Level = 5
Product Reference Guide 161
Symbologies
Code 39 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Code 39 symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 39 Length Control = Variable Length
Code 39 Length Control = Fixed Length
162 QuickScan® QD2100
Code 39
Code 39 Set Length 1
This feature specifies one of the barcode lengths for
Code 39 Length Control . Length 1
is the minimum label length if in
Mode, or the first fixed length if in
Fixed Length Mode. Length includes the barcode’s data characters only.
The length can be set from 0 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 0 to 50). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 39 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 21 for some examples of how to set this feature.
Table 21. Code 39 Length 1 Setting Examples
07 Characters
EXAMPLES
15 Characters 50 Characters
STEP
1
ACTION
Desired Setting
2
3
00 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 39 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
Product Reference Guide 163
Symbologies
Code 39 Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 02 = Length 1 is 2 Characters
CANCEL
164 QuickScan® QD2100
Code 39
Code 39 Set Length 2
This feature specifies one of the barcode lengths for
Code 39 Length Control . Length 2
is the maximum label length if in
Mode, or the second fixed length if
in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift
characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 39 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 22 for some examples of how to set this feature.
Table 22. Code 39 Length 2 Setting Examples
EXAMPLES STEP
1
2
ACTION
Desired Setting
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3
4
Scan SELECT CODE 39 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Product Reference Guide 165
Symbologies
Code 39 Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 39Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
166 QuickScan® QD2100
Code 39
Code 39 Interdigit Ratio
This feature specifies the ratio between an intercharacter space and module for Code 39 labels.
ENTER/EXIT PROGRAMMING MODE
Code 39 Interdigit Ratio = Disable
Code 39 Interdigit Ratio = 1
Code 39 Interdigit Ratio = 2
Code 39 Interdigit Ratio = 3
DEFAULT
Code 39 Interdigit Ratio = 4
Code 39 Interdigit Ratio = 5
Product Reference Guide 167
Symbologies
Code 39 Interdigit Ratio — cont.
ENTER/EXIT PROGRAMMING MODE
Code 39 Interdigit Ratio = 6
Code 39 Interdigit Ratio = 7
Code 39 Interdigit Ratio = 8
Code 39 Interdigit Ratio = 9
Code 39 Interdigit Ratio = 10
168 QuickScan® QD2100
Code 39
Code 39 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 39 Character Correlation = Disable
Code 39 Character Correlation = Enable
Product Reference Guide 169
Symbologies
Code 39 Stitching
This option enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
Code 39 Stitching = Disable
DEFAULT
Code 39 Stitching = Enable
170 QuickScan® QD2100
Code 32
Code 32
The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology.
Code 32 Enable/Disable
When disabled, the reader will not read Code 32 barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 32 = Disable
Code 32 = Enable
Code 32 Feature Setting Exceptions
NOTE
The following features are set for Code 32 by using these Code 39 settings:
Code 39 Quiet Zones on page 158
Code 39 Minimum Reads on page 159
Code 39 Decoding Level on page 160
Code 39 Interdigit Ratio on page 167
Code 39 Character Correlation on page 169
Product Reference Guide 171
Symbologies
Code 32 Check Character Transmission
Enable this option to transmit the check character along with Code 32 barcode data.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 32 Check Character Transmission = Don’t Send
Code 32 Check Character Transmission = Send
Code 32 Start/Stop Character Transmission
This option enables/disable transmission of Code 32 start and stop characters.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 32 Start/Stop Character Transmission = Don’t Transmit
Code 32 Start/Stop Character Transmission = Transmit
172 QuickScan® QD2100
Code 128
The following options apply to the Code 128 symbology.
Code 128 Enable/Disable
When disabled, the reader will not read Code 128 barcodes.
ENTER/EXIT PROGRAMMING MODE
Code 128 = Disable
DEFAULT
Code 128 = Enable
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Code 128
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 128 to Code 39 = Don’t Expand
Code 128 to Code 39 = Expand
Product Reference Guide 173
Symbologies
Code 128 Check Character Transmission
Enable this option to transmit the check character along with Code 128 barcode data.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 128 Check Character Transmission = Don’t Send
Code 128 Check Character Transmission = Send
Code 128 Function Character Transmission
Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 128 Function Character Transmission = Don’t Send
Code 128 Function Character Transmission = Send
174 QuickScan® QD2100
Code 128
Code 128 Sub-Code Change Transmission
Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding).
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 128 Sub-Code Change Transmission = Disable
Code 128 Sub-Code Change Transmission = Enable
Product Reference Guide 175
Symbologies
Code 128 Quiet Zones
This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MODE
Code 128 Quiet Zones = No Quiet Zones
Code 128 Quiet Zones = Quiet Zone on one side
Code 128 Quiet Zones = Quiet Zones on two sides
DEFAULT
Code 128 Quiet Zones = Auto
Code 128 Quiet Zones = Virtual Quiet Zones on two sides
176 QuickScan® QD2100
Code 128
Code 128 Minimum Reads
This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read..
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 128 Minimum Reads = 1
Code 128 Minimum Reads = 2
Code 128 Minimum Reads = 3
Code 128 Minimum Reads = 4
Product Reference Guide 177
Symbologies
Code 128 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
178 QuickScan® QD2100
Code 128 Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
Code 128 Decoding Level = 1
Code 128 Decoding Level = 2
DEFAULT
Code 128 Decoding Level = 3
Code 128
Code 128 Decoding Level = 4
Code 128 Decoding Level = 5
Product Reference Guide 179
Symbologies
Code 128 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Code 128 symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 128 Length Control = Variable Length
Code 128 Length Control = Fixed Length
180 QuickScan® QD2100
Code 128
Code 128 Set Length 1
This feature specifies one of the barcode lengths for Code 128 Length Control
. Length
1 is the minimum label length if in
Variable Length Mode, or the first fixed length if in
Fixed Length Mode. Length includes the barcode’s data characters only.
The length can be set from 1 to 80 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 80). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 128 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 23 for some examples of how to set this feature.
Table 23. Code 128 Length 1 Setting Examples
07 Characters
EXAMPLES
15 Characters 80 Characters
STEP
1
ACTION
Desired Setting
2
3
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 128 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’ ‘8’ AND ‘0’
Product Reference Guide 181
Symbologies
Code 128 Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 01 = Length 1 is 1 Character
CANCEL
182 QuickScan® QD2100
Code 128
Code 128 Set Length 2
This feature specifies one of the barcode lengths for Code 128 Length Control
. Length
2 is the maximum label length if in Variable Length
Mode, or the second fixed length if
Mode. Length includes the barcode’s data characters only.
The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 80 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 128 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 24 for some examples of how to set this feature.
Table 24. Code 128 Length 2 Setting Examples
EXAMPLES STEP
1
2
ACTION
Desired Setting
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3
4
Scan SELECT CODE 128 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘0’ and ‘F’
80 Characters
‘5’ AND 0’
Product Reference Guide 183
Symbologies
Code 128 Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 80 = Length 2 is 80 Characters
184 QuickScan® QD2100
Code 128
Code 128 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 128 Character Correlation = Disable
Code 128 Character Correlation = Enable
Product Reference Guide 185
Symbologies
Code 128 Stitching
This option enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
Code 128 Stitching = Disable
DEFAULT
Code 128 Stitching = Enable
186 QuickScan® QD2100
GS1-128
GS1-128
The following options apply to the GS1-128 symbology. (Also known as USS-128,
GTIN-128, UCC-128.)
GS1-128 Enable
This option enables/disables the ability of the reader to translate GS1-128 labels to the
GS1-128 data format. Options are:
• Transmit GS1-128 labels in Code 128 data format.
• Transmit GS1-128 labels in GS1-128 data format.
• Do not transmit GS1-128 labels.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
GS1-128 = Transmit in Code 128 data format
GS1-128 = Transmit in GS1-128 data format
GS1-128 = Do not transmit GS1-128 labels
Product Reference Guide 187
Symbologies
Interleaved 2 of 5 (I 2 of 5)
The following options apply to the I 2 of 5 symbology.
I 2 of 5 Enable/Disable
When disabled, the reader will not read I 2 of 5 barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 = Disable
I 2 of 5 = Enable
188 QuickScan® QD2100
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2 of 5 check character . When disabled, any check character in label is treated as a data character.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
I 2 of 5 Check Character Calculation = Disable
I 2 of 5 Check Character Calculation = Check Standard
(Modulo 10)
I 2 of 5 Check Character Calculation = Check German Parcel
I 2 of 5 Check Character Calculation = Check DHL
I 2 of 5 Check Character Calculation = Check Daimler Chrysler
I 2 of 5 Check Character Calculation = Check Bosch
Product Reference Guide 189
Symbologies
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Check Character Transmission
Enable this option to transmit the check character along with I 2 of 5 barcode data.
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 Check Character Transmission = Don’t Send
DEFAULT
I 2 of 5 Check Character Transmission = Send
190 QuickScan® QD2100
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Minimum Reads
This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read..
I 2 of 5 Minimum Reads = 2
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 Minimum Reads = 1
DEFAULT
I 2 of 5 Minimum Reads = 3
I 2 of 5 Minimum Reads = 4
Product Reference Guide 191
Symbologies
Interleaved 2 of 5 (I 2 of 5) — cont.
2 of 5 Decoding Level
This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and
Standard 2 of 5.
NOTE
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
192 QuickScan® QD2100
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5) — cont.
2 of 5 Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
2 of 5 Decoding Level = 1
2 of 5 Decoding Level = 2
DEFAULT
2 of 5 Decoding Level = 3
2 of 5 Decoding Level = 4
2 of 5 Decoding Level = 5
Product Reference Guide 193
Symbologies
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
I 2 of 5 Length Control = Variable Length
I 2 of 5 Length Control = Fixed Length
194 QuickScan® QD2100
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for
I 2 of 5 Length Control . Length 1 is
the minimum label length if in
Mode, or the first fixed length if in
Fixed Length Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters in increments of two.
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50). The length must be an even number.
2. Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT I 2 of 5 LENGTH 1 SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 27 for some examples of how to set this feature.
Table 25. I 2 of 5 Length 1 Setting Examples
6 Characters
EXAMPLES
14 Characters 50 Characters
STEP
1
ACTION
Desired Setting
2
3
4
2 Characters
Pad with leading zeroes to yield two digits
Scan ENTER/EXIT PROGRAMMING MODE
02
5
Scan SELECT I 2 of 5 LENGTH 1 SETTING
Scan Two Characters From
‘0’ and ‘2’
6 Scan ENTER/EXIT PROGRAMMING MODE
06
‘0’ and ‘6’
14
‘1’ and ‘4’
50
‘5’ AND ‘0’
Product Reference Guide 195
Symbologies
Interleaved 2 of 5 (I 2 of 5) — cont.
Datalogic 2 of 5 Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 06 = Length 1 is 6 Characters
CANCEL
196 QuickScan® QD2100
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for
I 2 of 5 Length Control . Length 2 is
the maximum label length if in
Mode, or the second fixed length if in
Fixed Length Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50, or 0 to ignore this length). The length must be an even number.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 =
20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT I 2 of 5 LENGTH 2 SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 28 for some examples of how to set this feature.
Table 26. I 2 of 5 Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
Pad with leading zeroes to yield two digits
3
4
Ignore This Length
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
00
4 Characters
04
EXAMPLES
14 Characters
14
5
6
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘4’ ‘1’ and ‘4’
50 Characters
50
‘5’ AND ‘0’
Product Reference Guide 197
Symbologies
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
198 QuickScan® QD2100
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
I 2 of 5 Character Correlation = Disable
I 2 of 5 Character Correlation = Enable
Product Reference Guide 199
Symbologies
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Stitching
This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
I 2 of 5 Stitching = Disable
I 2 of 5 Stitching = Enable
200 QuickScan® QD2100
Datalogic 2 of 5
The following options apply to the Datalogic 2 of 5 symbology.
Datalogic 2 of 5 Enable/Disable
When disabled, the reader will not read Datalogic 2 of 5 barcodes.
Datalogic 2 of 5
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Datalogic 2 of 5 = Disable
Datalogic 2 of 5 = Enable
Product Reference Guide 201
Symbologies
Datalogic 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Datalogic 2 of 5 Check Character Calculation = Disable
Datalogic 2 of 5 Check Character Calculation = Enable
202 QuickScan® QD2100
Datalogic 2 of 5
Datalogic 2 of 5 Minimum Reads
This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 Minimum Reads = 1
DEFAULT
I 2 of 5 Minimum Reads = 2
I 2 of 5 Minimum Reads = 3
I 2 of 5 Minimum Reads = 4
Datalogic 2 of 5 Decoding Level
NOTE
The Datalogic 2 of 5 Decoding Level feature is set using
.
Product Reference Guide 203
Symbologies
Datalogic 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Datalogic 2 of 5 symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Datalogic 2 of 5 Length Control = Variable Length
Datalogic 2 of 5 Length Control = Fixed Length
204 QuickScan® QD2100
Datalogic 2 of 5
Datalogic 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for
Datalogic 2 of 5 Length Control
.
Length 1 is the minimum label length if in Variable Length
Mode, or the first fixed length if in
Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters in increments of two.
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50). The length must be an even number.
2. Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT I 2 of 5 LENGTH 1 SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 27 for some examples of how to set this feature.
Table 27. Datalogic 2 of 5 Length 1 Setting Examples
6 Characters
EXAMPLES
14 Characters 50 Characters
STEP
1
ACTION
Desired Setting
2
3
4
2 Characters
Pad with leading zeroes to yield two digits
Scan ENTER/EXIT PROGRAMMING MODE
02
5
Scan SELECT Datalogic 2 of 5 LENGTH 1 SETTING
Scan Two Characters From
‘0’ and ‘2’
6 Scan ENTER/EXIT PROGRAMMING MODE
06
‘0’ and ‘6’
14
‘1’ and ‘4’
50
‘5’ AND ‘0’
Product Reference Guide 205
Symbologies
Datalogic 2 of 5 Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Datalogic 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 06 = Length 1 is 6 Characters
CANCEL
206 QuickScan® QD2100
Datalogic 2 of 5
Datalogic 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for
Datalogic 2 of 5 Length Control
.
Length 2 is the maximum label length if in Variable Length Mode, or the second fixed
length if in
Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50, or 0 to ignore this length). The length must be an even number.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 =
20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT Datalogic 2 of 5 LENGTH 2 SETTING.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 28 for some examples of how to set this feature.
Table 28. Datalogic 2 of 5 Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
Pad with leading zeroes to yield two digits
3
4
Ignore This Length
00
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING
4 Characters
04
EXAMPLES
14 Characters
14
5
6
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘4’ ‘1’ and ‘4’
50 Characters
50
‘5’ AND ‘0’
Product Reference Guide 207
Symbologies
Datalogic 2 of 5 Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Datalogic 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
208 QuickScan® QD2100
Datalogic 2 of 5
Datalogic 2 of 5 Interdigit Maximum Ratio
This feature specifies the maximum ratio between intercharacter space and module for
Datalogic 2 of 5.
ENTER/EXIT PROGRAMMING MODE
Datalogic 2 of 5 Interdigit Maximum Ratio = Disable
Datalogic 2 of 5 Interdigit Maximum Ratio = 1
Datalogic 2 of 5 Interdigit Maximum Ratio = 2
Datalogic 2 of 5 Interdigit Maximum Ratio = 3
DEFAULT
Datalogic 2 of 5 Interdigit Maximum Ratio = 4
Datalogic 2 of 5 Interdigit Maximum Ratio = 5
Product Reference Guide 209
Symbologies
Datalogic 2 of 5 Interdigit Maximum Ratio — cont.
Datalogic 2 of 5 Interdigit Maximum Ratio = 6
Datalogic 2 of 5 Interdigit Maximum Ratio = 7
Datalogic 2 of 5 Interdigit Maximum Ratio = 8
Datalogic 2 of 5 Interdigit Maximum Ratio = 9
Datalogic 2 of 5 Interdigit Maximum Ratio = 10
210 QuickScan® QD2100
Datalogic 2 of 5
Datalogic 2 of 5 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
I 2 of 5 Character Correlation = Disable
I 2 of 5 Character Correlation = Enable
Product Reference Guide 211
Symbologies
Datalogic 2 of 5 Stitching
This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Datalogic 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Datalogic 2 of 5 Stitching = Disable
Datalogic 2 of 5 Stitching = Enable
212 QuickScan® QD2100
Codabar
The following options apply to the Codabar symbology.
Codabar Enable/Disable
When disabled, the reader will not read Codabar barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Codabar = Disable
Codabar = Enable
Codabar
Product Reference Guide 213
Symbologies
Codabar Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional
Codabar check character. When disabled, any check characters in the label are treated as data characters.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Codabar Check Character Calculation = Don’t Calculate
Codabar Check Character Calculation = Enable AIM standard check char.
Codabar Check Character Calculation = Enable Modulo 10 check char.
214 QuickScan® QD2100
Codabar
Codabar Check Character Transmission
Enable this option to transmit the check character along with Codabar barcode data.
ENTER/EXIT PROGRAMMING MODE
Codabar Check Character Transmission = Don’t Send
DEFAULT
Codabar Check Character Transmission = Send
Codabar Start/Stop Character Transmission
Enable this option to enable/disable transmission of Codabar start and stop characters.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Codabar Start/Stop Character Transmission = Don’t Transmit
Codabar Start/Stop Character Transmission = Transmit
Product Reference Guide 215
Symbologies
Codabar Start/Stop Character Set
This option specifies the format of transmitted Codabar start/stop characters .
ENTER/EXIT PROGRAMMING MODE
Codabar Check Character Set = ABCD/TN*E
Codabar Check Character Set = ABCD/ABCD
Codabar Check Character Set = abcd/tn*e
DEFAULT
Codabar Check Character Set = abcd/abcd
216 QuickScan® QD2100
Codabar Start/Stop Character Match
When enabled, this option requires that start and stop characters match.
Codabar
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Codabar Start/Stop Character Match = Don’t Require Match
Codabar Start/Stop Character Match = Require Match
Product Reference Guide 217
Symbologies
Codabar Quiet Zones
This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MODE
Codabar Quiet Zones = Quiet Zone on one side
Codabar Quiet Zones = Quiet Zones on two sides
DEFAULT
Codabar Quiet Zones = Auto
Codabar Quiet Zones = Virtual Quiet Zones on two sides
218 QuickScan® QD2100
Codabar
Codabar Minimum Reads
This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read..
Codabar Minimum Reads = 2
ENTER/EXIT PROGRAMMING MODE
Codabar Minimum Reads = 1
DEFAULT
Codabar Minimum Reads = 3
Codabar Minimum Reads = 4
Product Reference Guide 219
Symbologies
Codabar Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
220 QuickScan® QD2100
Codabar Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
Codabar Decoding Level = 1
Codabar Decoding Level = 2
DEFAULT
Codabar Decoding Level = 3
Codabar
Codabar Decoding Level = 4
Codabar Decoding Level = 5
Product Reference Guide 221
Symbologies
Codabar Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Codabar symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Codabar Length Control = Variable Length
Codabar Length Control = Fixed Length
222 QuickScan® QD2100
Codabar
Codabar Set Length 1
This feature specifies one of the barcode lengths for Codabar Length Control
. Length 1 is the minimum label length if in
Mode, or the first fixed length if in
Mode. Length includes the barcode’s start, stop, check and data characters.
The length must include at least one data character.
The length can be set from 3 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 3 to 50). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODABAR LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 29 for some examples of how to set this feature.
Table 29. Codabar Length 1 Setting Examples
EXAMPLES STEP
1
ACTION
Desired Setting (and pad with leading zeroes)
2
3
03 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODABAR LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘3’
Scan ENTER/EXIT PROGRAMMING MODE
09 Characters
‘0’ and ‘9’
15 Characters
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Product Reference Guide 223
Symbologies
Codabar Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Codabar Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 03 = Length 1 is 3 Characters
CANCEL
224 QuickScan® QD2100
Codabar
Codabar Set Length 2
This feature specifies one of the barcode lengths for Codabar Length Control
. Length 2 is the maximum label length if in
Mode, or the second fixed length if
Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 3 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODABAR LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 30 for some examples of how to set this feature.
Table 30. Codabar Length 2 Setting Examples
EXAMPLES STEP
1
2
3
ACTION
Desired Setting (and pad with leading zeroes)
00 Ignore This
Length
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT CODE 39 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Product Reference Guide 225
Symbologies
Codabar Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select CodabarLength 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
226 QuickScan® QD2100
Codabar
Codabar Interdigit Ratio
This feature specifies the ratio between an intercharacter space and module for Codabar labels.
ENTER/EXIT PROGRAMMING MODE
Codabar Interdigit Ratio = Disable
Codabar Interdigit Ratio = 1
Codabar Interdigit Ratio = 2
Codabar Interdigit Ratio = 3
DEFAULT
Codabar Interdigit Ratio = 4
Codabar Interdigit Ratio = 5
Product Reference Guide 227
Symbologies
Codabar Interdigit Ratio — cont.
ENTER/EXIT PROGRAMMING MODE
Codabar Interdigit Ratio = 6
Codabar Interdigit Ratio = 7
Codabar Interdigit Ratio = 8
Codabar Interdigit Ratio = 9
Codabar Interdigit Ratio = 10
228 QuickScan® QD2100
Codabar
Codabar Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Codabar Character Correlation = Disable
Codabar Character Correlation = Enable
Product Reference Guide 229
Symbologies
Codabar Stitching
This option enables/disables stitching for Codabar labels. When parts of a Codabar barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Codabar Stitching = Disable
Codabar Stitching = Enable
230 QuickScan® QD2100
Code 11
The following options apply to the Code 11 symbology.
Code 11 Enable/Disable
When disabled, the reader will not read Code 11 barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 11 = Disable
Code 11 = Enable
Code 11
Product Reference Guide 231
Symbologies
Code 11 Check Character Calculation
This option enables/disables calculation and verification of optional Code 11 check character.
ENTER/EXIT PROGRAMMING MODE
Code 11 Check Character Calculation = Disable
Code 11 Check Character Calculation = Check C
Code 11 Check Character Calculation = Check C and K
Code 11 Check Character Calculation = Check K
DEFAULT
232 QuickScan® QD2100
Code 11
Code 11 Check Character Transmission
This feature enables/disables transmission of an optional Code 11 check character.
ENTER/EXIT PROGRAMMING MODE
Code 11 Check Character Transmission = Don’t Send
DEFAULT
Code 11 Check Character Transmission = Send
Product Reference Guide 233
Symbologies
Code 11 Minimum Reads
This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read..
Code 11 Minimum Reads = 2
ENTER/EXIT PROGRAMMING MODE
Code 11 Minimum Reads = 1
DEFAULT
Code 11 Minimum Reads = 3
Code 11 Minimum Reads = 4
234 QuickScan® QD2100
Code 11
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Code 11 symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 11 Length Control = Variable Length
Code 11 Length Control = Fixed Length
Product Reference Guide 235
Symbologies
Code 11 Set Length 1
This feature specifies one of the barcode lengths for
Code 11 Length Control . Length 1
is the minimum label length if in
Mode, or the first fixed length if in
Fixed Length Mode. Length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 11 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 31 for some examples of how to set this feature.
Table 31. Code 11 Length 1 Setting Examples
EXAMPLES STEP
1
ACTION
Desired Setting (pad with leading zeroes)
2
3
02 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 11 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘2’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
236 QuickScan® QD2100
Code 11 Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 11 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 04 = Length 1 is 4 Characters
CANCEL
Code 11
Product Reference Guide 237
Symbologies
Code 11 Set Length 2
This feature specifies one of the barcode lengths for
Code 11 Length Control . Length 2
is the maximum label length if in
Mode, or the second fixed length if
Mode. Length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 11 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 32 for some examples of how to set this feature.
Table 32. Code 11 Length 2 Setting Examples
EXAMPLES STEP
1
2
3
ACTION
Desired Setting (pad with leading zeroes)
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT CODE 11 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘0’ and ‘F’
50 Characters
‘3’ AND 2’
238 QuickScan® QD2100
Code 11 Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 11 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
Code 11
Product Reference Guide 239
Symbologies
Code 11 Interdigit Ratio
This feature specifies the ratio between an intercharacter space and module for Code 11 labels.
ENTER/EXIT PROGRAMMING MODE
Code 11 Interdigit Ratio = Disable
Code 11 Interdigit Ratio = 1
Code 11 Interdigit Ratio = 2
Code11 Interdigit Ratio = 3
DEFAULT
Code 11 Interdigit Ratio = 4
Code 11 Interdigit Ratio = 5
240 QuickScan® QD2100
Code 11 Interdigit Ratio — cont.
ENTER/EXIT PROGRAMMING MODE
Code 11 Interdigit Ratio = 6
Code 11
Code 11 Interdigit Ratio = 7
Code 11 Interdigit Ratio = 8
Code 11 Interdigit Ratio = 9
Code 11 Interdigit Ratio = 10
Product Reference Guide 241
Symbologies
Code 11 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
242 QuickScan® QD2100
Code 11 Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
Codabar Decoding Level = 1
Codabar Decoding Level = 2
DEFAULT
Codabar Decoding Level = 3
Code 11
Codabar Decoding Level = 4
Codabar Decoding Level = 5
Product Reference Guide 243
Symbologies
Code 11 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 11 Character Correlation = Disable
Code 11 Character Correlation = Enable
244 QuickScan® QD2100
Code 11
Code 11 Stitching
This option enables/disables stitching for Code 11 labels. When parts of a Code 11 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Code 11 Stitching = Disable
Code 11 Stitching = Enable
Product Reference Guide 245
Symbologies
Standard 2 of 5
The following options apply to the Standard 2 of 5 symbology.
Standard 2 of 5 Enable/Disable
When disabled, the reader will not read Standard 2 of 5 barcodes.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 = Disable
Standard 2 of 5 = Enable
246 QuickScan® QD2100
Standard 2 of 5
Standard 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Standard 2 of 5 Check Character Calculation = Disable
Standard 2 of 5 Check Character Calculation = Enable
Standard 2 of 5 Check Character Transmission
This feature enables/disables transmission of an optional Standard 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Check Character Transmission = Send
Standard 2 of 5 Check Character Transmission = Don’t Send
DEFAULT
Product Reference Guide 247
Symbologies
Standard 2 of 5 Minimum Reads
This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Minimum Reads = 1
DEFAULT
Standard 2 of 5 Minimum Reads = 2
Standard 2 of 5 Minimum Reads = 3
Standard 2 of 5 Minimum Reads = 4
Standard 2 of 5 Decoding Level
NOTE
The Standard 2 of 5 Decoding Level feature is set using 2 of 5 Decoding
.
248 QuickScan® QD2100
Standard 2 of 5
Standard 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Standard 2 of 5 symbology.
Variable Length — For variable length decoding, a minimum and maximum length may be set.
Fixed Length — For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Standard 2 of 5 Length Control = Variable Length
Standard 2 of 5 Length Control = Fixed Length
Product Reference Guide 249
Symbologies
Standard 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for
Standard 2 of 5 Length Control
.
Length 1 is the minimum label length if in Variable Length
Mode, or the first fixed length if in
Fixed Length Mode. Length includes the barcode’s check and data charac-
ters.
The length can be set from 1 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT STANDARD 2 OF 5 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 33 for some examples of how to set this feature.
Table 33. Standard 2 of 5 Length 1 Setting Examples
STEP
1
ACTION
Desired Setting
2
3
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
07 Characters
EXAMPLES
15 Characters
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
250 QuickScan® QD2100
Standard 2 of 5 Set Length 1 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
DEFAULT 08 = Length 1 is 8 Characters
CANCEL
Standard 2 of 5
Product Reference Guide 251
Symbologies
Standard 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for
Standard 2 of 5 Length Control
.
Length 2 is the maximum label length if in Variable Length Mode, or the second fixed
length if in
Fixed Length Mode. Length includes the barcode’s check and data charac-
ters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT STANDARD 2 OF 5 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad , that represent
the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
Table 34 for some examples of how to set this feature.
Table 34. Standard 2 of 5 Length 2 Setting Examples
STEP
1
2
3
ACTION
Desired Setting (pad with leading zeroes)
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
07 Characters
‘0’ and ‘7’
EXAMPLES
15 Characters
‘1’ and ‘5’
5 Scan ENTER/EXIT PROGRAMMING MODE
50 Characters
‘5’ AND ‘0’
252 QuickScan® QD2100
Standard 2 of 5 Set Length 2 — cont.
ENTER/EXIT PROGRAMMING MODE
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
Standard 2 of 5
Product Reference Guide 253
Symbologies
Standard 2 of 5 Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
Standard 2 of 5 Character Correlation = Disable
Standard 2 of 5 Character Correlation = Enable
254 QuickScan® QD2100
Standard 2 of 5
Standard 2 of 5 Stitching
This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Stitching = Disable
Standard 2 of 5 Stitching = Enable
Product Reference Guide 255
Symbologies
ISBT 128
The following options apply to the ISBT 128 symbology.
ISBT 128 Enable/Disable
Enables/Disables ability of imager to decode ISBT 128 labels.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
ISBT 128 = Disable
ISBT 128 = Enable
ISBT 128 Concatenation
Enables/disables ISBT128 concatenation of 2 labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT
ISBN 128 Concatenation = Disable
ISBN 128 Concatenation = Enable
256 QuickScan® QD2100
ISBT 128
ISBT 128 — cont.
ISBT 128 Force Concatenation
When enabled, this feature forces all ISBT 128 labels to be concatenated.
This option is only valid when ISBT 128 Concatenation is enabled.
).
NOTE
DEFAULT
ENTER/EXIT PROGRAMMING MODE
ISBT 128 Force Concatenation = Disable
ISBT 128 Force Concatenation = Enable
ISBT 128 Advanced Concatenation Options
Contact Customer Support to set up pairs of label types for concatenation.
NOTE
Product Reference Guide 257
Symbologies
Code 4
The following options apply to the Code 4 symbology.
Code 4 Enable/Disable
Enables/Disables ability of imager to decode Code 4 labels.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 4 = Disable
Code 4 = Enable
258 QuickScan® QD2100
Code 4 Check Character Transmission
This feature enables/disables transmission of an optional Code 4 check character.
Code 4
ENTER/EXIT PROGRAMMING MODE
Code 4 Check Character Transmission = Don’t Send
DEFAULT
Code 4 Check Character Transmission = Send
Code 4 Hex to Decimal Conversion
This feature enables/disables the conversion of hexidecimal label data to decimal label data.
ENTER/EXIT PROGRAMMING MODE
Code 4 Hex to Decimal Conversion = Disable
DEFAULT
Code 4 Hex to Decimal Conversion = Enable
Product Reference Guide 259
Symbologies
Code 5
The following options apply to the Code 5 symbology.
Code 5 Enable/Disable
Enables/Disables ability of imager to decode Code 5 labels.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 5 = Disable
Code 5 = Enable
260 QuickScan® QD2100
Code 5 Check Character Transmission
This feature enables/disables transmission of an optional Code 5 check character.
Code 5
ENTER/EXIT PROGRAMMING MODE
Code 5 Check Character Transmission = Don’t Send
DEFAULT
Code 5 Check Character Transmission = Send
Code 5 Hex to Decimal Conversion
This feature enables/disables the conversion of hexidecimal label data to decimal label data.
ENTER/EXIT PROGRAMMING MODE
Code 5 Hex to Decimal Conversion = Disable
DEFAULT
Code 5 Hex to Decimal Conversion = Enable
Product Reference Guide 261
Symbologies
Code 4 and Code 5 Common Configuration Items
The following options apply to both Code 4 and Code 5 symbologies.
Code 4 and 5 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
• Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
• Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
• Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level .
NOTE
This configuration item applies to Code 4 and Code 5.
262 QuickScan® QD2100
Code 4 and Code 5 Common Configuration Items
Code 4 and Code 5 Common Configuration Items — cont.
Code 4 and 5 Decoding Level — cont.
ENTER/EXIT PROGRAMMING MODE
Code 4 and Code 5 Decoding Level = 1
Code 4 and Code 5 Decoding Level = 2
DEFAULT
Code 4 and Code 5 Decoding Level = 3
Code 4 and Code 5 Decoding Level = 4
Code 4 and Code 5 Decoding Level = 5
Product Reference Guide 263
Symbologies
Code 4 and Code 5 Common Configuration Items — cont.
Code 4 and Code 5 Minimum Reads
This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read.
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 4 or Code 5 Minimum Reads = 1
Code 4 or Code 5 Minimum Reads = 2
Code 4 or Code 5 Minimum Reads = 3
Code 4 or Code 5 Minimum Reads = 4
264 QuickScan® QD2100
Follett 2 of 5
The following options apply to the Follett 2 of 5 symbology.
Follett 2 of 5 Enable/Disable
Enables/Disables ability of imager to decode Follett 2 of 5 labels.
Follett 2 of 5
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Follett 2 of 5 = Disable
Follett 2 of 5 = Enable
Product Reference Guide 265
Symbologies
NOTES
266 QuickScan® QD2100
Appendix A
Technical Specifications
Table 35 contains Physical and Performance Characteristics, User Environment and
Regulatory information.
Table 36 provides Standard Cable Pinouts.
Table 35. Technical Specifications
Description Item
Physical Characteristics
Dimensions
Weight (without cable)
Color
Electrical Characteristics
2.8 in. H x 6.7 in. L x 2.6 in. W
(7.1 cm H x 17.1 cm L x 6.6 cm W)
Approximately 4.2 oz. (119 g)
Black or White
Voltage & Current
QD2110 4-14 VDC
QD2130 5.0 VDC +/-10%
180mA @ 5V Typical Idle
345mA @ 5V Typical Scanning
Performance Characteristics
Light Source
Roll (Tilt) Tolerance
Pitch Tolerance
Skew (Yaw) Tolerance
Scan Angle
Depth of Field
Minimum Element Width
Print Contrast Minimum
617nm LEDs
± 45° from normal
± 65°
± 65°
43° ± 3°
4.0 mil 3.0 - 9.5 cm
5.0 mil 2.3 - 14 cm
7.5 mil 1.5 - 26.5 cm
10 mil (80% UPC) 1.3 - 37.5 cm
13 mil (100% UPC) 2.5 - 46.5 cm
15 mil to 48 cm
20 mil to 59 cm
3 mil
15% minimum reflectance
Product Reference Guide 267
Decode Capability
Item
Interfaces Supported
User Environment
Operating Temperature
Storage Temperature
Humidity
Drop Specifications
Ambient Light Immunity
Contaminants
Spray/rain
Dust/particulates
Beeper Volume
Beeper Tone (frequency)
Electrostatic Discharge
Regulatory
Electrical Safety
EMI/RFI
Description
UPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII;
Code 32 (Italian Pharmacode); Code 128; ISBT 128; I 2 of 5; Standard 2 of 5; Code 11; Codabar; GS1-128; Code 93; MSI; GS1 DataBar Omnidirectional, GS1 DataBar Limited, GS1 DataBar Expanded; EAN 13 ISBN;
Datalogic 2 of 5; Follet 2/5; Code 4, code 5.
RS-232 Std., RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports 5B and 9B), USB Com Std., USB Keyboard, USB Alternate Keyboard, USB
Keyboard Apple, USB-OEM, Keyboard Wedge (AT with or w/o Alternate
Key, IBM AT PS2 with or w/o Alternate Key, PC-XT, IBM 3153, IBM Terminals 31xx, 32xx, 34xx, 37xx make only and make break keyboard, and
Digital Terminals VT2x, VT3xx and VT4xx).
32° to 122° F (0° to 50° C)
-40° to 158° F (-40° to 70° C)
5% to 95% relative humidity, non-condensing
Withstands multiple 5 ft./1.524 m drops to concrete.
Immune to direct exposure of normal office and factory lighting conditions, as well as direct exposure to sunlight.
IEC 529-IPX2
IEC 529-IP5X
User-selectable: three levels
User-selectable: three tones
Conforms to ±20 kV air/direct discharge and ±8 kV of contact discharge.
USA: UL 60950, Canada: CAN/CSA-C22.2 No. 60950, EN60950/
IEC60950, NOM-019-SCFI
FCC Part 15 Class B, ICES-003 Class B, European Union EMC Directive,
Australia Class B, Taiwan EMC, Japan VCCI/MITI, Korea KCC
268 QuickScan® QD2100
Standard Cable Pinouts
Standard Cable Pinouts
Figure 7 and Table 36 provide standard pinout information for the imager’s cable.
Figure 7. Standard Cable Pinouts
Pin
7
8
5
6
9
10
3
4
1
2
Cable
Cable Strain Relief
Pin 1
Bottom of Imager
Interface Cable Port
Pin 10
To Host
Cable Clip (Latch)
The signal descriptions in
apply to the connector on the imager and are for reference only.
Table 36.
Standard Cable Pinouts — Imager Side
RS-232
RTS (out)
OEM USB Keyboard Wedge
GND
RX
TX
VCC
CTS (in)
GND
VCC
IBM_B
IBM_A
D+
D-
GND
VCC
CLKIN (KBD side)
DATAIN (KBD side)
GND
VCC
CLKOUT (PC side)
DATAOUT (PC side)
Product Reference Guide 269
NOTES
270 QuickScan® QD2100
Appendix B
Standard Defaults
The most common configuration settings are listed in the “Default” column of
.
The settings in this table are as applied to a standard RS-232 interface. See
a listing of default exceptions to this list as appled to other interface types. Page references are also provided for feature descriptions and programming barcodes for each parameter.
A column has also been provided for recording of your preferred default settings for these same configurable features.
Table 37. Standard Defaults
Parameter Default Your Setting Page Number
General Features
Double Read Timeout
Label Gone Timeout
Power On Alert
Good Read: When to Indicate
Good Read Beep Type
Good Read Beep Frequency
Good Read Beep Length
Good Read Beep Volume
Good Read LED Duration
Scan Mode
Stand Mode Triggered Timeout
Scanning Active Time
Flash On Time
Flash Off Time
Stand Mode Sensitivity
Green Spot Duration
0.4 Second
160 ms
4 Beeps
After Decode
Mono
Medium
80 ms
High
LED on until next trigger pull
Trigger Single
0.5 Seconds
5 Seconds
1 Second
600 ms
Medium
300 ms
27
35
37
39
40
29
31
33
22
23
24
24
26
17
19
21
Product Reference Guide 271
272
Parameter
RS-232
RS-232/USB-COM
Keyboard Wedge
USB-OEM
No Delay
Disable
Enable
‘ACK’
‘NAK’
600 ms
3 Retries
Ignore Errors
Detected
Enable
‘D’
‘E’
Default
9600
8 Data Bits
1 Stop Bit
None
Disable
U.S. Keyboard
Caps Lock OFF
Numlock Key
Unchanged
Disable
100 ms
No Delay
100 ms
1 ms
Your Setting Page Number
Handheld Scanner
QuickScan® QD2100
Parameter Default
Data Editing
Symbologies
UPC-A
UPC-A Check Character Transmission
UPC-A Number System Character Transmission
UPC-E
UPC-E Check Character Transmission
UPC-E Number System Character Transmission
GTIN
EAN 13
EAN 13 Check Character Transmission
No Global Prefix
Global Suffix = 0x0D
(CR)
Disable
Disable
Disable
No Char Conversion
Enable
Enable
Don’t Expand
Transmit
1
2
Enable
Send
Don’t Expand
Don’t Expand
Transmit
2
Disable
Enable
Send
Transmit
Your Setting Page Number
Product Reference Guide 273
274
Parameter
EAN 8
EAN 8 Check Character Transmission
UPC/EAN Global Settings
Add-Ons
Default
Disable
1
Enable
Send
Disable
1
2
Disable
Disable
GS1 DataBar Omnidirectional
GS1 DataBar Omnidirectional Enable/
GS1 DataBar Omnidirectional GS1-128
GS1 DataBar Omnidirectional Minimum
GS1 DataBar Expanded
GS1 DataBar Expanded Enable/Disable
GS1 DataBar Expanded GS1-128 Emulation
GS1 DataBar Expanded Minimum Reads
GS1 DataBar Expanded Length Control
Disable P2, P5 and
P8
70 ms
Disable
2
1
1
Disable
Disable
1
Disable
Disable
1
Variable
Your Setting Page Number
QuickScan® QD2100
Parameter
GS1 DataBar Expanded Set Length 1
GS1 DataBar Expanded Set Length 2
GS1 DataBar Limited
GS1 DataBar Limited Enable/Disable
GS1 DataBar Limited GS1-128 Emulation
GS1 DataBar Limited Minimum Reads
Code 39
Code 39 Check Character Calculation
Code 39 Check Character Transmission
Code 39 Start/Stop Character Transmission
Code 32
Code 32 Feature Setting Exceptions
Code 32 Check Character Transmission
Code 32 Start/Stop Character Transmission
Code 128
Default
1
74
Disable
Disable
1
Disable
3
Don’t Send
Don’t Transmit
Enable
Enable
Calculate
Send
Don’t Transmit
Disable
Auto
2
3
Variable
2
50
4
Disable
Enable
Your Setting Page Number
Product Reference Guide 275
276
Parameter
Code 128 Check Character Transmission
Code 128 Character Correlation
GS1-128
Interleaved 2 of 5
I 2 of 5 Check Character Calculation
I 2 of 5 Check Character Transmission
I 2 of 5 Character Correlation
Datalogic 2 of 5
Datalogic 2 of 5 Enable/Disable
Datalogic 2 of 5 Check Character Calculation
Datalogic 2 of 5 Minimum Reads
Datalogic 2 of 5 Length Control
Transmit in Code
128 Data Format
Disable
Disable
Send
2
3
Variable
12
100
Disable
Disable
Default
Don’t Expand
Send
Auto
1
3
Variable
1
80
Disable
Enable
Enable
Disable
2
Variable
Your Setting Page Number
QuickScan® QD2100
Parameter
Datalogic 2 of 5 Character Correlation
Codabar
Codabar Check Character Calculation
Codabar Check Character Transmission
Codabar Start/Stop Character Transmission
Codabar Start/Stop Character Set
Codabar Start/Stop Character Match
Code 11
Default
12
100
Disable
Disable
Disable
Don’t Calculate
Send
Don’t Transmit abcd/abcd
Don’t Require Match
Auto
2
3
Variable
3
50
4
Disable
Disable
Code 11 Check Character Calculation
Code 11 Check Character Transmission
Disable
1
Check C and K
Send
2
Variable
4
50
Your Setting Page Number
Product Reference Guide 277
278
Parameter
Standard 2 of 5
Standard 2 of 5 Enable/Disable
Standard 2 of 5 Check Character Calculation
Standard 2 of 5 Check Character Transmission
Standard 2 of 5 Decoding Level
Standard 2 of 5 Length Control
Standard 2 of 5 Character Correlation
ISBT 128
ISBT 128 Advanced Concatenation
Code 4
Code 4 Check Character Transmission
Code 4 Hex to Decimal Conversion
Code 5
Code 5 Check Character Transmission
Code 5 Hex to Decimal Conversion
Default
4
3
Disable
Disable
Disable
Disable
Send
2
3
Variable
8
50
Disable
Disable
Disable
Disable
Enable
Disable
Disable
Enable
Enable
Disable
Enable
Enable
Your Setting Page Number
QuickScan® QD2100
Parameter Default
Code 4 and Code 5 Common Configuration Items
Code 4 and Code 5 Minimum Reads
3
1
Follett 2 of 5
Disable
Your Setting Page Number
Product Reference Guide 279
Default Exceptions
Table 37 lists standard default settings as applied to a standard RS-232 interface.
Table 38 provides a listing of default exceptions to that list as applied to the other inter-
face types.
Table 38. Default Exceptions by Interface Type
Parameter
Interfaces: IBM 46XX Port 5B, IBM 46XX Port 9B, USB-OEM
Global Suffix
Double Read Timeout
Interfaces: All Keyboard Wedge, USB Keyboard
No unique settings
Interface: RS232-WN
Expand UPC-A to EAN-13
UPC-E Check Character Transmission
Parity
Handshaking Control
Transmission Label ID Code
GS1-128 AIM ID
UPCE Label ID Character(s)
EAN 8 Label ID Character(s)
EAN 13 Label ID Character(s)
Code ISBN Label ID Character(s)
Code 39 Label ID Character(s)
Interelaved 2of5 Label ID Character(s)
Code Standard 2/5 Label ID Character(s)
Codabar Label ID Character(s)
Code 128 Label ID Character(s)
GS1-128 Label ID Character(s)
Datalogic 2 of 5 Label ID Character(s)
ISBT 128 Label ID Character(s)
UPCE P2 Label ID Character(s)
UPCE/P5 Label ID Character(s)
UPCE/GS1-128 Label ID Character(s)
Default Excption
No Global Suffix
500 msec
K
P
H
N
M
I
A
A
C
C
H
K
C
Enable
Disable
Odd Parity
RTS/CTS
Prefix
Disable
C
B
280 QuickScan® QD2100
Parameter
EAN8/P2 Label ID Character(s)
EAN8/P5 Label ID Character(s)
EAN8/GS1-128 Label ID Character(s)
EAN13/P2 Label ID Character(s)
EAN13/P5 Label ID Character(s)
EAN13/GS1-128 Label ID Character(s)
GS1 DataBar 14 (Omnidirectional) Label ID Character(s)
GS1 DataBar Expanded Label ID Character(s)
GS1 DataBar Limited Label ID Character(s)
Character Conversion
Interface: RS232-OPOS
Baud Rate
Transmission Label ID Code
GS1-128 AIM ID
UPCA Label ID Character(s)
UPCE Label ID Character(s)
EAN 8 Label ID Character(s)
EAN 13 Label ID Character(s)
Code ISBN Label ID Character(s)
Code 39 Label ID Character(s)
Code 32 Label ID Character(s)
Interelaved 2of5 Label ID Character(s)
Code Standard 2/5 Label ID Character(s)
Codabar Label ID Character(s)
Code 11 Label ID Character(s)
Code 128 Label ID Character(s)
GS1-128 Label ID Character(s)
UPCA/P2 Label ID Character(s)
UPCA/P5 Label ID Character(s)
UPCA/GS1-128 Label ID Character(s)
UPCE P2 Label ID Character(s)
Product Reference Guide
Default Exceptions
Default Excption
B
B
A
A
B
A
E
E
E
CR to `
T k
R b
N
P
V
X
115200 Baud
Prefix
Disable
C
B
@
D
A
Q
H
F
G
281
Parameter
UPCE/P5 Label ID Character(s)
EAN8/P2 Label ID Character(s)
EAN8/P5 Label ID Character(s)
EAN8/GS1-128 Label ID Character(s)
EAN13/P2 Label ID Character(s)
EAN13/P5 Label ID Character(s)
EAN13/GS1-128 Label ID Character(s)
GS1 DataBar 14 (Omnidirectional) Label ID Character(s)
GS1 DataBar Expanded Label ID Character(s)
GS1 DataBar Limited Label ID Character(s)
GTIN W/o Add on Label ID Character(s)
GTIN Addon 2 Label ID Character(s)
GTIN Add on 5 Label ID Character(s)
GTIN Add on 8 Label ID Character(s)
$A
$B
$C
$D t v
# u
Default Excption
I
J
L
M
K
*
282 QuickScan® QD2100
Appendix C
LED and Beeper Indications
The imager’s beeper sounds and its LED illuminates to indicate various functions or errors on the imager. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the imager’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming barcode labels.
Product Reference Guide 283
LED and Beeper Indications
INDICATION
Power-up Beep
Good Read Beep
ROM Failure
Limited Scanning
Label Read
Imager Active
Mode
Imager
Disabled
Green Spot is on continuously
Green Spot flashes momentarily a
The imager is in the process of powering-up.
DESCRIPTION LED
A label has been successfully scanned by the imager.
LED behavior for this indication is configurable via the feature “ Good Read: When to
Indicate ”
There is an error in the imager's software/programming
Indicates that a host connection is not established when the IBM or
USB interface is enabled.
The imager is active and ready to scan.
The imager has been disabled by the host.
While in Stand Mode or Trigger
Object Sense mode the green spot shall be on while in stand watch state.
Upon successful read of a label, the software shall turn the green spot on for the time specified by the configured value.
Flashes
N/A
The LED is lit steadily a
The LED blinks continuously
N/A
N/A
BEEPER
Imager beeps four times at highest frequency and volume upon powerup.
The imager will beep once at current frequency, volume, mono/bitonal setting and duration upon a successful label scan.
Imager sounds one error beep at highest volume.
Imager 'chirps' six times at the highest frequency and current volume.
N/A
N/A
N/A
N/A
Programming Mode - The following indications ONLY occur when the imager is in Programming Mode.
Label Programming
Mode Entry
A valid programming label has been scanned.
LED blinks continuously
Imager sounds four low frequency beeps.
Label Programming
Mode Rejection of
Label
A label has been rejected.
N/A
Imager sounds three times at lowest frequency & current volume.
Label Programming
Mode Acceptance of Partial Label
Label Programming
Mode Acceptance of Programming
In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
Configuration option(s) have been successfully programmed via labels and the imager has exited Programming Mode.
N/A
N/A
Imager sounds one short beep at highest frequency & current volume.
Imager sounds one high frequency beep and 4 low frequency beeps followed by reset beeps.
Label Programming
Mode Cancel Item
Entry a.
Cancel label has been scanned.
N/A
Except when in sleep mode or when a Good Read LED Duration other than 00 is selected
Imager sounds two times at low frequency and current volume.
284 QuickScan® QD2100
Error Codes
Error Codes
Upon startup, if the imager sounds a long tone, this means the imager has not passed its automatic Selftest and has entered FRU
1
isolation mode. If the imager is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.
NUMBER OF LED
FLASHES/BEEPS
4
5
1
2
6
14
ERROR
Configuration
Interface PCB
Imager Module
[Reserved]
Digital PCB
CPLD/Code Mismatch
CORRECTIVE ACTION
Contact Helpdesk for assistance
1. Field Replaceable Unit (FRU)
Product Reference Guide 285
NOTES
286 QuickScan® QD2100
Appendix D
Sample Barcodes
The sample barcodes in this appendix are typical representations for their symbology types.
UPC-A
0
12345 67890
5
EAN-13
3 4 5 6 7 8 9 0 1 2 3 4 0
Code 39
123ABC
Code 128
12345678901231
Product Reference Guide
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
Interleaved 2 of 5
287
Code 32
Codabar
Code 93
Code 11
288 QuickScan® QD2100
GS1 DataBar (RSS)
GS1 DataBar variants must be enabled to read the barcodes below (see GS1
).
NOTE
GS1 DataBar (RSS)
1234890hjio9900mnb
(GS1 DataBar Expanded)
GS1 DataBar-14
55432198673467
(GS1 DataBar Omnidirectional Truncated)
10293847560192837465019283746029478450366523
(GS1 DataBar Expanded Stacked)
08672345650916
(GS1 DataBar Limited)
90876523412674
(GS1 DataBar Omnidirectional Stacked)
78123465709811
(GS1 DataBar Omnidirectional Stacked)
Product Reference Guide 289
NOTES
290 QuickScan® QD2100
Appendix E
Keypad
Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.
0
1
2
3
4
5
Product Reference Guide 291
292
A
C
6
8
7
9
B
QuickScan® QD2100
E
D
F
Product Reference Guide 293
NOTES
294 QuickScan® QD2100
Appendix F
Scancode Tables
Control Character Emulation
Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables.
These apply to Wedge and USB Keyboard platforms.
Control Character 00 — Characters from 00 to 0x1F are sent as control character
Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Control Character 01 — Characters from 00 to 0x1F are sent as control character
Ctrl+Capital Key, special keys are located from 0x80 to 0xA1.
Control Character 02 — Special keys are located from 00 to 0x1F and characters from
0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage
1252 —
).
Product Reference Guide 295
Microsoft Windows Codepage 1252
Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
306 QuickScan® QD2100
NOTES
Microsoft Windows Codepage 1252
Product Reference Guide 307
NOTES
308 QuickScan® QD2100
B bar codes
RS-232 baud rate
RS-232 parameters parity
barcodes cancel
numeric barcodes
RS-232 parameters parity
Beeper
Pitch, Good Read
23
,
24
Volume, Good Read
26
Beeper, Good Read
21
C
Cable Pinouts
Clear to Send
Code 39 Format
Conversion, case
Conversion, character
CTS
D
Decode Capability
Defaults
Depth of Field
E
Electrical Safety
EMI/RFI
Error Codes
Errors
Product Reference Guide
Index
G
Good Read, Beeper
21
Pitch
23
,
24
Volume
26
Good Read, Beeper –
21
Good Read, Beeper Pitch –
23
,
24
Good Read, Beeper Volume –
26
Green Spot
H
Handheld Scanner
Host Resets
I
IBM Connection
7
IBM interface selection
12
IBM Standard Format
Indications
Interface Cable
6
Interface Type
8
Interfaces Supported
K keyboard support
KEYBOARD WEDGE (KBW) interface selection
Keyboard Wedge Connection
7
L
Light Source
M
Mixed OEM Standard + Code 39 Format
309
N numbers lock key
P
Performance Characteristics
Physical Characteristics
Pitch – Good Read, Beeper
23
,
24
Pitch Tolerance
Prefix/Suffix
Print Contrast Minimum
Product Specifications
Programming Barcodes
8
R
Read, Beeper – Good
21
Read, Beeper Pitch – Good
23
,
24
Read, Beeper Volume – Good
26
Request to Send
Roll (Tilt) Tolerance
RS-232 interface selection
12
RS-232 Serial Connection
6
RTS
S sample bar codes code 128
code 39
interleaved 2 of 5
select digits/characters
Serial Output
Skew (Yaw) Tolerance
Standard Cable Pinouts
Suffix
symbology types
T
Table Top Scanner
U
UPC
310
USB Connection
7
USB interface selection
12
User Environment
V
Volume – Good Read, Beeper
26
X
XON/XOFF
QuickScan® QD2100
ASCII Chart
Hex
No.
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
ASCII
Char.
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
FF
CR
SO
SI
BS
HT
LF
VT
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
Hex
No.
3C
3D
3E
3F
38
39
3A
3B
34
35
36
37
30
31
32
33
2C
2D
2E
2F
28
29
2A
2B
24
25
26
27
20
21
22
23
ASCII
Char.
>
?
<
=
;
:
8
9
6
7
4
5
2
3
0
1
/
.
-
,
*
+
)
(
$
%
’
&
SP
!
“
#
Hex
No.
5C
5D
5E
5F
58
59
5A
5B
54
55
56
57
50
51
52
53
4C
4D
4E
4F
48
49
4A
4B
44
45
46
47
40
41
42
43
ASCII
Char.
^
_
]
\
Z
[
X
Y
T
U
V
W
R
S
P
Q
N
O
L
M
J
K
H
I
F
G
D
E
@
A
B
C
Hex
No.
7C
7D
7E
7F
78
79
7A
7B
74
75
76
77
70
71
72
73
6C
6D
6E
6F
68
69
6A
6B
64
65
66
67
60
61
62
63
ASCII
Char.
}
|
~
DEL
{ z x y v w u t s r p q n o l m k j i h g f d e b c a
‘
Australia
Datalogic Scanning Pty Ltd
Telephone: [61] (2) 9870 3200 [email protected]
France and Benelux
Datalogic Scanning Sarl
Telephone: [33].01.64.86.71.00
Germany
Datalogic Scanning GmbH
Telephone: 49 (0) 61 51/93 58-0 [email protected]
India
Datalogic Scanning India
Telephone: 91- 22 - 64504739 [email protected]
Italy
Datalogic Scanning SpA
Telephone: [39] (0) 39/62903.1
Japan
Datalogic Scanning KK
Telephone: 81 (0)3 3491 6761 [email protected]
Latin America
Datalogic Scanning, Inc
Telephone: (305) 591-3222 [email protected]
Singapore
Datalogic Scanning Singapore PTE LTD
Telephone: (65) 6435-1311 [email protected]
Spain and Portugal
Datalogic Scanning Sarl Sucursal en España
Telephone: 34 91 746 28 60 [email protected]
United Kingdom
Datalogic Scanning LTD
Telephone: 44 (0) 1923 809500 [email protected]
www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
© 2008-2009 Datalogic Scanning, Inc.
R44-2933 (Rev. B) 2/09
advertisement
Related manuals
advertisement