NIVOFLIP MAK-100

Add to my manuals
2 Pages

advertisement

NIVOFLIP MAK-100 | Manualzz
Thank you for choosing a NIVELCO instrument.
We are sure that you will be satisfied throughout its use!
1. GENERAL INDTRODUCTION, OPERATION
NIVOFLIP
NIVOFLIP MAK-100- type magnetic level switches are suitable for level switching of variuos liquids.
MAK-100 type magnetic level switches are used for magnetic-lamella bypass level indicator (named
NIVOFLIP) as an optional level switch.
OPERATION PRINCIPLE:
Mounted on suitable connection flanges on the side of the tank the liquid level in the bypass tube and the
tank is equal. In the stainless steel bypass tube a magnetic float tracks the level of the liquid. In the float
a permanent magnet is incorporated, which operates the MAK-100 type adjustable positioned magnetic level
switch through the stainless steel side of the tube, and provides non-contact signal transfer to the
microswitch.
Electronic connection is performed with cable gland, wired with a maximal 2.5 mm cross sectioned cable.
Installation of the level switch is made by 2 pieces of hose clamps. Position of the switch can be changed to
adjust the needed switching level. The level switches are available in normal and Ex versions.
2
2. TECHNICAL DATA
MAK-100-0
MAK-100-6
Medium temperature
max. +130 °C
Ambient temperature
-20°C…+80°C
See: Temperature data
for Ex versions table
TYPE
Material of the switch-housing
Switch
Switch rating
Electrical connections
Paint coated aluminium cast
1 microswitch, with NO / NC contacts
250V AC12 2.5 A
Only Ex ia certified and approved contact
220V DC13 0.3 A
isolator should be used for supply!
cable gland: M20x1.5 terminal for max. 2.5 mm wire cross section
2
Mechanical protection
IP 65
Electrical protection
Ex marking
Mass
BKI11ATEX0004X ▪ mak1100a0600h_02 ▪ 1/2
Class I.
–
II 1G
1.5 kg
Manufacturer:
NIVELCO Process Control Co.
H-1043 Budapest, Dugonics u. 11.
Phone: (36-1) 889-0100 Fax: (36-1) 889-0200
E-mail: [email protected] www.nivelco.com
2.1 GENERAL DATA
Temperature classes
Class
Max. medium temperature
T5
T4
+95°C
+130°C
-20°C…+60°C
-20°C…+70°C
-20°C…+80°C
2.3 ORDER CODE
Code
None
Ex II 1G
•
•
•
•
The instrument do not require maintenance, but
the instrument (depending on the application)
may need to be checked or cleaned regularly.
Users manual
Warranty card
Declaration of Conformity
2 pcs. Hose clamps
2.5 MOUNTING
NIVOFLIP M A K – 1 0 0 –
Ex marking
5. MAINTENANCE
0
6
2.4 DIMENSIONS
Switching
level
7
6
5
4
3
2
1
0
Switching differential ± 35 mm
Ambient temperature
T6
+80°C
2.2 ACCESSORIES
6. STORAGE
Ambient temperature: -25...max:+80°C,
see: ” Temperature data for Ex versions table”
Relative humidity: max. 98% non-condensing!
7. WARRANTY
NIVELCO provides warranty of 3 (three) years
in compliance with details described in the
Warranty Card.
3. WIRING
4. CONDITIONS OF EX APPLICATIONS
NC
NC
NO NO
GND
The housing of the instrument should be grounded
by its grounding screw to the EP system.
Only Ex ia certified and approved contact isolator
should be used for supply!
mak1100a0600h_02
2015 October
NIVELCO reserves the right to change
technical data without notice!
BKI11ATEX0004X ▪ mak1100a0600h_02 ▪ 2/2