Cross Technologies 4116-24T11 S-Band to L-Band Translator, 2.2-2.4 GHz 0.95-1.15 GHz Owner's Manual

Add to My manuals
17 Pages

advertisement

Cross Technologies 4116-24T11 S-Band to L-Band Translator, 2.2-2.4 GHz 0.95-1.15 GHz Owner's Manual | Manualzz

Instruction Manual

Model 4116-24T11

Translator, S-Band to L-Band

Weather Resistant* Unit

June 2014, Rev. C

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.

C ROSS T ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005 • FAX (770) 886-7964 • Toll Free 888-900-5588

WEB www.crosstechnologies.com

E-MAIL [email protected]

INSTRUCTION MANUAL

MODEL 4116-24T11 Translator, S-Band to L-Band

TABLE OF CONTENTS

Warranty

1.0 General

1.1 Equipment Description

1.2 Technical Characteristics

2.0 Installation

2.1 Connection to AC Input Power

2.2 Message Protocol

2.3 M&C Commands

2.4 M&C Queries

2.5 Ethernet Interface Installation

2.5.1 Methods of Connection

2.5.2 Ethernet Configuration

2.5.3 Webpage M&C

2.5.4 SNMP Configuration

2.6 Translator Outline Drawings

2.7 Physical Interface

2.8 Installation/Operation

9

10

11

14

6

7

9

9

15

16

PAGE

2

3

3

5

5

4

5

WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.

All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies,

Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein.

C ROSS T ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005 • FAX (770) 886-7964 • Toll Free 888-900-5588

WEB www.crosstechnologies.com • E-MAIL [email protected]

4116-24T11 Manual, Rev. C Page 2 06/04/14

MODEL 4116-24T11 Translator, S-Band to L-Band, Weather Resistant*

1.0 General

1.1 Equipment Description

The 4116-24T11 Translator converts 2.2 - 2.4 GHz to 0.95 - 1.15 GHz. Front panel LEDs provide indication of

DC Power, and PLL Alarm. The S-band to L-band gain is +30 dB, maximum. Connectors are Type N female for the L-band out, S-band in and S-band in Monitor and SMA female for the external 10 MHz reference input.

Gain, mute, and internal 10 MHz frequency are controlled by the M&C (Ethernet and/or Status/Control). In

AUTO, the 10 MHz reference stays in external if the external level is in the +2 to +8 dBm range. The 4116 is powered by a 100-240 ± 10% VAC power supply, and mounted in a 8”W X 6”H X 16”D Weather Resistant* enclosure.

NOTE: *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges. They are designed to be located “out in the elements”

(water, sleet, snow, etc.) but they are not designed to be “submerged under” water. If an extended temperature range is required, there is an Extended Temperature option (Option W21; -30˚C to +60˚C) available at an additional cost. Contact Cross for quote.

STATUS /

CONTROL ..

....

J6

C

ROSS

T

ECHNOLOGIES INC.

MODEL 4116 TRANSLATOR

RF IN RF IN MON

ETHERNET

AC IN

J7 POWER .

J8

FUSE

F1

10M IN

ALARM

10M OUT

RF OUT

J3 J4

J1 J2 J5

FIGURE 1. Model 4116-24T11, Translator Front Panel

0

S-band

MON

2.2 -

2.4

GHz

S-band

IN

4116-24T11

Translator

Block Diagram

T

T

E

R

S

P

L

I

2.8 GHz BP

5.1 GHz

PLL, ATT, CONTROL

1.5 GHz LP

A

T

T

V

A

R

0.95 - 1.15 GHz

L-band OUT

3.85 GHz

EXT

10 M 10 M

TO

PLLS

CONTROLLER

M&C

FIGURE 1A. Model 4116-24T11 Translator, Block Diagram

4116-24T11 Manual, Rev. C Page 3 06/04/14

1.2 Technical Characteristics

TABLE 1.0

4116-24T11 Translator Specifications**

Input Characteristics

Input Impedance/Return Loss

Frequency

50 Ω /14 dB

2.2 to 2.4 GHz

15 dBm at maximum gain

-50 to -30 dBm

Noise Figure, Maximum

Input Level Range

Output Characteristics

Impedance/Return Loss

Frequency

Output Level Range

Output 1 dB Compression

Mute

Channel Characteristics

Gain at Fc

Input to Output Isolation

Spurious, Inband

50 Ω / 14 dB, Mute & UnMute

0.95 to 1.15 GHz

-20 to 0 dBm

+10 dBm, maximum gain

>50 dB @ 0 dBm Output

+30 ±3 dB max., (+30 to 0 dB variable in 0.5±0.5 dB steps)

> 45 dB, minimum, at +20 dB gain

SIGNAL RELATED <-60 typ., -55 min dBC in band, -15 to 0 dBm out;

SIGNAL INDEPENDENT,<-60 dBm

Spurious, Out of band

Intermodulation

Frequency Response

Frequency Sense

LO Characteristics

LO <-60 dBm spurs, signal independent; 0.5 to .95 and 1.15 to 2.5 GHz out;

LO= -80 dBm at input and output

<-50 dBC for two carriers at 4 MHz spacing, each at -5 dBm out

±1.0 dB, over RF band; ± 0.5 dB, 40 MHz BW

Non-inverting

LO Step Size

Frequency Accuracy

10 MHz Level In/Mon

None; Fixed Translation

± 0.05 ppm maximum over temp internal reference; external reference input

Input = +2 to +8 dBm in. Monitor Output = Input Level ± 1.0 dB, 50

Ω

Phase Noise @ F (Hz) >

dBC/Hz

100 MHz

-70

1kHz

-78

10kHz

-83

100kHz

-100

1MHz

-110

Controls, Indicators

Gain, 10M Frequency

PLL Alarm

Power

Other

S-Band In, Mon. Connector

L-Band Out Connector

Gain and internal 10 MHz frequency via Ethernet M&C or Status/Control Connector

Red LED, External Contact Closure

Green LED

Cable Connector(s)

(Weather Resistant)

10 MHz Connectors

Size

Power

Type N (female), 50 Ω (weather resistant)

Type N (female), 50 Ω (weather resistant)

Status/Control Connector, MS3112E14-18S; Mating Cable Connector, MS3116F14-18P.

Ethernet Conector, RJF21B; Mating Cable Connector, RJF6G; Cable interface,

Standard RJ45.

AC Input Connector, Clipper Series, CL1M1102, Mating Cable Connector, CL1F1101.

(Unless otherwise specified, the mating connector is provided preassembled onto a

standard NEMA 5-15 U.S. power cord.)

SMA (female), 50 Ω (weather resistant)

8”W X 6”H X 16”D Weather Resistant* Enclosure

100-240 ±10% VAC, 47 - 63 Hz, 25 watts maximum /

FCI Clipper Series CL1M1102 Connector

*+0 to +50 degrees C; Specifications subject to change without notice

4116-24T11 Manual, Rev. C Page 4 06/04/14

2.0 Installation

The 4116-24T11 Translator consists of a 8” Wide X 6“ High X 16” Deep, Weather Resistant* enclosure.

A switching, ± 12, +24, +5 VDC power supply provides power for the internal assemblies. The 4116-24T11 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panel.

See Drawing 2.5 for mounting dimensions.

Figure 2.0: Model 4116-24T11 Translator

2.1 Connection to AC Input Power

The 4116-24T11 utilizes a pre-assembled AC power input cable as described below.

Table 2.0: 4116-24T11 AC Power Input Connector

Pin Input Connector Pin Description

1 100-240 ±10% VAC, 47-63 Hz, 20 watts max.

2 Neutral

3 Ground

2.2 Message Protocol

The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit.

All messages consist of ASCII printable characters so standard terminals and terminal emulator programs may be used to control and monitor the unit. All messages begin with the open bracket character “} (ASCII 0x7B) and end with the close bracket character “}” (ASCII 0x7D). Messages consisting of commands to set or change operating parameters and modes of the unit begin with “C” (ascii 0x43) followed by a command specific character. Messages consisting of queries to report operating parameters and modes begin with “S”

(ASCII 0x53) followed by a parameter specific character.

4116-24T11 Manual, Rev. C Page 5 06/04/14

2.3 M&C Commands

The following tables summarize the commands and status queries applicable to the

4116-24T11 frequency converter.

*

PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.

Table 2.1 - Model 4116-24T11 M&C Commands

Table 2.1: Model 4116-24T11 M&C Commands

Command

Set Gain

Syntax

{aaCGxxx}

Description where: xxx = 3 characters

Range: 0 to +30 in 0.5 dB steps

Example: {aaCG155} sets the gain to 15.5 dB

Set Serial Interface {aaCIx} where: x = 0 to select RS232 x = 1 to select RS422 x = 2 to select RS485

Set Mute {aaCMx} where: x = 1 to mute the output x = 0 to unmute the output

Set RS485 address {aaCRxx}

Set Int. 10 MHz reference offset {aaCOxxxxx} where: xx = 2 characters

Range: 20 to 0 where: xxxxx = 5 characters

Range: +2000 to -2000

Set 10 MHz reference mode {aaCEx} where: x = 1 to select internal reference x = 2 to select external reference

x = 3 to select auto reference

4116-24T11 Manual, Rev. C Page 6 06/04/14

2.4 M&C Queries

Table 2.2 Model 4116-24T11 M&C Commands

Table 2.3: Model 4116-24T11 M&C Queries

Command

Gain

Syntax

{aaSG}

Description

Returns {aaSGxxx} where: xxx = 3 characters

Range: 0 to 30.0 in 0.5 dB steps

Example: {aaSG155} indicates the current gain setting is +15.5 dB

10 MHz reference {aaSE}

Serial Interface

RS485 address

{aaSI}

{aaSR}

Returns {aaSEx} where: x = 1 if Internal 10 MHz reference is selected x = 2 if External 10 MHz reference is selected x = 3 if Auto 10 MHz reference is selected

Returns {aaSIx} where: x = 0 if RS232 is selected x = 1 if RS422 is selected x = 2 if RS485 is selected

Returns {aaSAxx} where: xx = 2 characters

Range: 0 to 31 continued on page 8...

4116-24T11 Manual, Rev. C Page 7 06/04/14

Table 2.3 Model 4116-24T11 M&C Commands (Continued from page 7)

Table 2.3: Model 4116-24T11 M&C Queries - Continued...

Command Syntax

Int. 10 MHz reference offset {aaSO}

Description

Returns {aaSOxxxxx} where: xxxxx = 5 characters

Range: +2000 to -2000

Summary Alarm {aaSA} Returns {aaSAx} where: x = 0 if no summary alarm, x = 1 if summary alarm

Internal Temperature {aaST}

Model and firmware revision {aaSV}

Returns {aaSTxxx} where: xxx = 3 characters

Range (-99 to +99) degrees Celsius

returns {aaSVxxxxxxxxyyyy} where: xxxxxxxx = unit model number yyyy = unit firmware rev.

Unit Status {aaSS} returns {aaSSwxyz} where:

w = summary alarm: 0 = off, 1 = on x = ref. source: 1 = internal, 2 = extenal y = oven status: 0 = normal, 1 = oven warmup

IP Address {aaSi} returns {aaSixxx.xxx.xxx.xxx} where:

the xxx.xxx.xxx.xxx = the unit’s IP address.

Subnet Mask {aaSs} returns {aaSsxxx.xxx.xxx.xxx} where:

the xxx.xxx.xxx.xxx = the unit’s Subnet mask.

Mute {aaSM} returns {aaSMx} where:

x = 0 if mute is off x = 1 if mute is on

4116-24T11 Manual, Rev. C Page 8 06/04/14

2.5 ETHERNET Interface Installation and Operation

The 4116-24T11 Translator is equipped with a 10/100 Base-T compatible Ethernet interface for control and monitoring of its operating parameters. An HTML script interface allows the user to monitor and control the converter using a standard web browser. SNMP (Simple Network Management Protocol) is also supported.

Contact Cross Technologies for the SNMP MIB file.

2.5.1 Methods of Connection

Directly Connected to a PC:

For control from a local PC, attach the 4116-24T11’s Ethernet port to the Ethernet network connector on the

PC using a crossover RJ-45 cable.

LAN Connection

For LAN connections, attach the 4116-24T11 Ethernet port to the LAN using a normal RJ-45 cable.

Use any PC on the LAN to connect to the 4116-24T11.

2.5.2 Ethernet Configuration

Each 4116-24T11 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your network manager. The 4116-24T11 is set at the factory with a static address which is 192.168.123.2. The device server in the 4116-24T11 has a built in HTTP based configuration manager that is used to configure network settings. To access the configuration manager open a web browser and enter the IP address of the

4116-24T11 in the browser's address field. The window shown in Figure 2-A will appear. As delivered, there is no password set. Choose your user name and password here or leave those fields blank and click OK to proceed to the configuration manager webpage.

4116-24T11 Manual, Rev. C

Figure 2-A Password Screen

Page 9 06/04/14

Figure 2-B Configuration Manager Screen

In the left frame of the configuration manager click on Network to display the Network Settings screen.

Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 192.168.192.47).

Click apply settings in the left frame to apply the new settings in the network device.

4116-24T11 Manual, Rev. C Page 10 06/04/14

2.5.3 Webpage M & C

Enter the following address in a web browser to access the M & C webpage: http://<ip address of 41xx>/serial/0/setup.htm where <ip address> is the IP address of the unit.

Figure 2-C: Model 4116-24T11 Webpage

2.5.4 SNMP Configuration

Setting of SNMP parameters such as Community Write and Community Read strings requires a Telnet ® connection to port 9999. The following instructions explain how to establish such a Telnet ® connection using

Windows XP's Hyper Terminal utility .

Start the Hyper Terminal application and select “New Connection” from the “File” drop down menu.

The next screen is a “Connect To” dialog box. Select TCP/IP (Winsock) from the “Connect” drop down menu.

Enter the IP address of the 4116-24T11 in the “Host address:” field and 9999 in the “Port number” field.

Figure 2-E shows an example of the Hyper Terminal settings required to access the SNMP configuration menu.

4116-24T11 Manual, Rev. C Page 11 06/04/14

Figure 2-E: Telnet ® Settings in Hyper Terminal

Once the Telnet ® connection is established you will be prompted to “Press Enter for Setup Mode”. Press enter and a menu of device server configuration options will appear (see Figure 2-F). Select menu item 3, “SNMP configuration.” You will be prompted to enter SNMP community read and write strings. After setting your desired community strings you will be prompted to “Enter IP addresses for SNMP traps.” You must enter at least one and up to four IP addresses of SNMP managers that will access the unit. This is required even though

SNMP traps are not implemented. The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server.

4116-24T11 Manual, Rev. C Page 12 06/04/14

Figure 2-F: Device Server Configuration Menu

4116-24T11 Manual, Rev. C Page 13 06/04/14

2.6 Outline Drawing shows the input and output connection on the front panel and top view of the 4116-24T11.

7.88

6.62

4.2

STATUS/CONTROL

CONNECTOR

Weatherized

MS3112E14-18S

18 pin connector.

(See table 2.4)

ETHERNET CONNECTOR

Weatherized RJF21B

Standard RJ45 Ethernet

Connector.

STATUS /

CONTROL ..

....

J6

C

ROSS

T

ECHNOLOGIES INC.

MODEL 4116 TRANSLATOR

RF IN RF IN MON

ETHERNET

AC IN

J7

POWER

.

J8

FUSE

F1

10M IN

ALARM

10M OUT

RF OUT

J3 J4

J1 J2

RF INPUT

Type N, 50 Ω

-50 to -30 dBm

2.2 - 2.4 GHz

S-Band Input.

RF IN MON

Type N, 50 Ω

10MHz INPUT

SMA (female) 50 Ω

Insert External 10MHz)

Reference here (+2 to +8 dBm).

J5

10MHz OUTPUT

SMA, 50 Ω

Output level =

+2 to +8 dBm ±1.0 dB.

POWER IN

AC input 100-240 ±10% VAC

47-63 Hz.Weatherized CL1M1102

Connector. (See Table 2.0)

POWER LED

Lights GREEN when DC voltage is present from AC power supply.

Fuse

1A 250V - 1.24” X .25” slow blow

Up ALARM LED

Red LED indicates unit alarm.

RF OUT

Type N, 50 Ω

0 to +30dBm

0.95 to 1.15 GHz

L-Band Output.

5.500

5.775

1/4-20 Tapped Thru, 4 Places

15.5

12.00

15.875

4116-24T11 Manual, Rev. C

7.50

Page 14 06/04/14

2.7 Physical Interface

All 4115 and 4116 units provide a RS232/RS422/RS485 interface port and a 10/100 Base-T Ethernet port.

Both ports are available when the unit is installed and powered up. Commands may be sent to either port at any time and they will be processed in the order that they are received. The RS232/RS422/RS485 signals connect via a multipurpose MS3112E14-18S, 18 pin connector as shown in Figure 2.5.1 below.

The Ethernet signals connect via a standard RJ45 connector.

Table 2.4: Monitor and Control Connector

Pin Signal Description

A Chassis Ground

N Summary Alarm Normally Closed

P Summary Alarm Common

R Summary Alarm Normally Open

E RS422/RS485 Data Out-

F Signal Ground

C RS422/RS485 Data In-

D RS422/RS485 Data Out+, RS232 Data Out

B RS422/RS485 Data In+, RS232 Data In

NOTE: Planning Ethernet Access

It is recommended that IP knowledgeable customer personnel be consulted as a resource in the

installation and use of the Ethernet access features of the Cross Technologies product.

4116-24T11 Manual, Rev. C Page 15 06/04/14

2.8 Installation/Operation

Installing and Operating the 4116-24T11 Translator

1. Connect a -50 dBm to -30 dBm signal to RF In, (Drawing 2.6).

2. Connect the RF Output, to the external equipment.

3. Using the pre-assembled AC power input cable (furnished), connect 100-240 ±10% VAC,

47 - 63 Hz, 25 watts maximum, to AC IN connector on the front panel.

4. If a custom length power cable must be made, refer to description below for connections*.

5. Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Drawing 2.6).

6. Set the gain insuring that the output level is always in the range of -20 to 0 dB.

7. Select either INT (for internal 10 MHz ref), AUTO (for internal 10 MHz ref UNLESS a external

10 MHz, +2 to +8 dBm signal is connected to J2), or EXT (for external 10 MHz, +2 to +8 dBm reference that is inserted at J3) via Ethernet or serial command.

8. Check that a 10 MHz, signal is present at the 10 MHz REF OUTPUT at the same level as the input,

±0.5 dBm (J4 - Drawing 2.6).

9. AC Fuse - The fuse is a 1.25” x .25” - 1.5 amp (slow blow) and is inserted in the fuse F1 position.

NOTE: If a fuse continues to open, the power supply is most likely defective.

4116-24T11 Manual, Rev. C Page 16 06/04/14

C ROSS T ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com

E-MAIL [email protected]

Printed in USA

4116-24T11 Manual, Rev. C Page 17 06/04/14