Sierra Products EasyFire MODEL EF 3801 Operating instructions

Add to my manuals
11 Pages

advertisement

Sierra Products EasyFire MODEL EF 3801 Operating instructions | Manualzz

EF3801B-AL Pellet Heater

Installation & Operating Instructions

Please read this entire manual before installation. Save these instructions.

SAFETY NOTICE

< CAUTION: HOT W HILE IN OPERATION. KEEP

CHILDREN, CLOTHING AND FURNITURE AWAY.

CONT ACT MAY CAUSE SKIN BURNS.

< IF THIS HEATER IS NOT PROPERLY INSTALLED,

A HOUSE FIRE MAY RESULT.

< FAILU RE TO CO M PLY W ITH OW NE RS ' MANU AL

INSTRUCTIONS WILL VOID YOUR WARRANTY!

PLEASE READ THIS ENTIRE MANUAL BEFORE

INSTALLATION AND USE OF THIS PELLET FUEL-

BURNING ROOM HEATER. FAILURE TO FOLLOW

TH ES E IN ST RU CT ION S C OU LD RE SU LT IN

PROPERT Y DAMAGE, BODILY INJURY OR EVEN

INSTALLER: PLEASE LEAVE THIS MANUAL WITH

THE OWNER!!

WARNING: THIS HEATER SHOULD NOT BE

INSTALLED IN A SLEEPING ROOM.

GENERAL INFORMATION

Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a professional service pers on. More fre qu en t cle an ing m ay be re qu ired due to fue l quality, ex ce ss ive lint fr om carpetin g, b ed ding m ate rial, etc . It is im pera tive that con trol com partm ents , burn ers and circu lating air passageways of the heater be kept clean.

The EASYFIRE Pellet heater has been designed and approved for burning w oo d p ellet fu el on ly. Burning other forms of fuel is not permitted and will void all warranties.

This unit has been approved for use with a 3" Type L Pellet

Vent System .

NEVER use gasoline, gasoline-type lantern fuels, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire. Keep all such liquids well away from the heater while it is in use.

Ashes must be disposed of in a metal container with a tight fitting lid and placed on a noncombustible floor or ground, we ll away fr om all fu els , pe nd ing fina l dispo sa l.

NOTE : During the first few burns the high tem perature paint and sealant used in manufacture will emit some odor and smoke. Open doors and windows to the outside for proper ventilation during the first burn cycle and curing of the p aint.

This heate r, whe n insta lled, m us t be electrica lly gro un de d in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-

2006.

Provide adequate clearances around air openings into the combustion chamber and adequate accessibility clearance for servicing and proper operation. Never obstruct the front opening of the hea ter.

The heater may be installed as a free-standing unit mounted on a non -com bu stib le protec tive floo r pa d or he arth. O r it m ay be m ounted into an existing U. L. approved w ood stove chimney. Non-combustible floor protection is required and m us t be used wh en placin g th e hea ter on any com bu stib le m ate rial.

The pellet heater must be operated with a power source and will not operate using natural draft. If there is a powe r failure the heater will shut down. If the 12 volt back system is installed, the heater will automatically switch to 12 volt power.

The EasyFire Pellet Heater has been listed by OM NI-Test

Laboratories, Inc. to ASTM, U.L.,and EPA Standards.

Sierra Products, Inc.

506 1 Brook s St., S te. B

Montclair, CA 91763

Listed by OMNI-Test Laboratories, Inc.

Rep ort No . 256-S-01-4

Figure 2

Figure 1 -Overall Dimensions

OU TS IDE CO M BU ST ION AIR IS M AND ATO RY IN

MO BILE OR MO DULAR HOM E INSTALLATIONS.

CAU TIO N: D O N OT CO NN EC T T O AN Y AIR

DISTRIBUTION DUCT O R SYSTEM .

VENTING AND INSTALLATION

CLEARANCES

CONT ACT LOCAL BUILDING OFFICIALS ABOUT RE-

STRICTIONS AND INSTALLATION INSPECTION

RE QU IREM EN TS IN Y OU R AR EA.

A LISTED, 4" MINIMU M T YPE "L" PELLET VENT PIPE

IS MANDATORY ON ALL INSTALLATIONS.

DO NO T INSTALL A FLUE DAMPER IN THE EXHAUST

VENTING SYSTEM OF THIS UNIT, DO NOT CONNECT

THIS UNIT TO A CHIMNEY FLUE SERVING ANOT HER

APPLIANCE.

Use only listed 3" minimum Type "L" pellet vent and components for installation. The exhaust vent system must be attached to the unit and to each adjoining section.

All joints for connector pipe shall be fastened with at least three screws. If vented horizontally, joints shall be made gas-tight by sealing with high temperature silicon or m aterial spec ified by ve nt pipe m anu facturer. Failure to use listed pellet vent pipe or install it per m anufacturers ins tructio ns will void your warranty.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE

VENT MANU FACTURER

Vent Pipes’ inner and outer diameters may vary. Check with v ent p ipe m anu factu rer for furthe r deta ils.

W ARN ING : Installatio n o f a M ob ile Ho m e Atta chm ent Kit

P/N 10412 and outside comb ustion air is m and atory in

mobile or modular home installations although it may also be used in all residential applications.

An outs ide air inlet MU ST be provided for combustion

and ven tilation air. The air inlet must remain unrestricted while unit is in use. Outside air connection is located in the rear of the heater (Figure 2). Use conduit pipe or metal flex pipe and/or fittings to mak e the air intake hook-up.

CAUTION: STRUCTURAL INTEGRITY OF THE MO BILE

HOME FLOOR, WALLS AND CEILING/ROOF MUST BE

MAINTAINED.

1.

W hen deciding on the location of your heater and vent pipe, try to minimize the alteration and reframing of struc tural com pon ents of the building . Vent pipe must be installed so that access is provided for

inspection and cleaning.

2.

Avoid installing heater in high traffic areas. Keep children well away from the heater when in operation.

3.

A 3" clearance to combustibles must be maintained for horizontal and vertical venting. W hen passing throu gh ceilings or walls, you m us t us e a liste d w all thimble, making sure all combustible materials and insulation products are a minimum of 3" away from the pellet vent pipe.

4.

A no n-c om bu stib le he arth pad must be use d if inst alled on a ca rpe t, w oo d flo or o r oth er co m bu sti-

ble material (see Figure 3).

5.

W hen installing the exhaust vent into an existing chimney, a tee must be installed behind the heater be fore going up into the chim ne y. This is nec es sa ry in order to remove fly ash accumulation.

6.

Exit termina tion (distanc e to op ening s):

a. 3 ft. minimum above any forced air inlet located within 1 0 ft.

b. 4 ft. minimum below and horizontally or 1 ft. minimum above any door, window or gravity air inlet into any building.

2

Figure 3

c. 2 ft. m inim um to an adja cen t building and 7 ft.

m inim um abo ve grade whe n loca ted a djac ent to public walkways.

Figure 5

Figure 4

3

Figure 6

UNIT INSTALLATION

Route the power supply cord so that it does not touch any of the exterior com ponents of the he ater.

1.

W hen exiting through the wall with your type L Pellet vent p ipe, you m ay go straight ou t throu gh a wall thim ble. You m us t co nn ec t a p ellet vent te e at this point and exte nd th e vent pipe at leas t 3' (three feet) vertically outside to provide good draft and allow the gases to exit. The tee must have a clean out cap for inspection and regular cleaning (Figure 4). Horizontal runs must be limited to 2' (two fe et). A w all ban d is requ ired fo r ev ery 4' (four feet) minimum on a vertical run at an exterior wa ll.

2.

All pellet vent pipe connections including exit at the rear of the heater should be sealed with high tem pe rature silicone (45 0°) or m eta llic duc t tap e. T his prevents smok e and soot leakage into the living area.

If this is not done, there is a possibility that the room fan will pick up any leakage and blow it into the room.

AUTOLITE INSTALLATION INSTRUCTIONS

Th e A uto Lite Sys tem is fa cto ry ins talle d w ith th e only installation requ irem ents being the optiona l therm osta t.

Wall Thermostat Installation:

Th e wa ll therm osta t is des igned to autom atically reg ulate the room tem perature from the control panel heat setting to the “Off” setting based upon room temperature.

Rem ember to leave the control panel on the "Medium or

High" position when utilizing the wall thermostat feature.

The following is a step by step procedure for installing the optional wall therm ostat. Note conne ction terminals on left side of unit at rear (Fig ure 7,8). Use 18/2 therm ostat wire for the installation.

a. Unplug he ater from wall outlet and 12V DC power!

b. Rem ove factory jump wire and hook up thermostat wires to terminals (Fig ure 7,8).

c. Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature.

d. Run thermostat wires from heater to thermostat along wa ll or und er ca rpet e tc. an d ho ok wires to thermostat terminals. On new construction you can, of course, run wire in the walls before sheet rock or paneling is done.

Figure 7 Rear Connection Panel

e. Reco nnect AC power.

f. Make sure all wiring is completed before plugging the E AS YFIR E H eate r bac k into the w all outlet.

IMPORTANT - Any electrical work performed on the

EA SY FIRE H ea ter shou ld be don e by qualifie d perso nn el.

Figure 8 Stove Connection Panel

Remote Control Thermostat Installation:

Th e re m ote the rm os tat is desig ne d to autom atic ally regulate the room temperature from the control panel heat setting to the “Off” setting base d upon roo m temp erature and place m ent o f the re m ote therm osta t. Rem em ber to leave the control panel on the "Medium or High" position when utilizing the wall thermostat feature.

The following is a step by step procedure for installing the optional remote thermostat. Note connection terminals on rear of un it (Fig ure 1,2).

Autolite Wiring Diagram

a. Unplug he ater from wall outlet and 12V DC power!

b. Mount millivolt style remote receiver box to rear of stove using double-sided tape.

b. Rem ove factory jump wire and hook up thermostat wires to terminals (Fig ure 7,8).

d. Re con nec t AC pow er an d follow instructions with remote thermostat regarding set up.

IMPORTANT - Any electrical work performed on the

EA SY FIRE H ea ter shou ld be don e by qualifie d perso nn el.

DOOR HANDLE ASSEMBLY

The door handle and latch must be assembled and adjusted prior to the operation of the stove.

1.

Position hand le ass em bly throu gh d oor a nd s ecu re with collar by sliding over shaft and tightening with allen wrench provided (Figure 9).

2.

Position latch on end of shaft with flat facing allen screw.

Depending on gasket, shaft will protrude approx. 1/4" through back of latch collar. Snug allen screw.

4

Fig ure 9 Do or h andle a sse m bly

3.

To adjust door, close and turn handle so latch co nta cts strike r. D oo r ga sk et m us t co nta ct firm ly against front face of unit. This can be checked by closing against a piece of pape r. Firmly tug on paper, if it m oves with solid re sis tan ce the door is prope rly adjusted.

FUEL SELECTION

Proper fuel selection is critical. Your stove requires 1/4" diam ete r woo d pellets. The pellets m us t be spec ifically manufactured for use pellet heaters. Use of fuel noncon form ing fu el will cause th e sto ve to o pera te erra tically.

Additionally, a low ash content of below 1% is will reduce your cleaning and maintenance time. Store pellets in a clean dry area. Do not use pellets that have been damp or h av e a m ois tu re le ve l a bo ve 5% .

The quality o f pe llet fue l varies from bra nd to b rand . This will affect the efficiency of your heater. W e suggest that you try several brands until you find one that gives you a clean eff icient burn. P oor q uality pellets will burn rich w ith black s oot a nd a sh w ill accum ulate q uick ly. Qua lity pellets will burn clean and ash build up will be m inim al.

stove operates based on the EasyFire digital control system requirements. If the house AC power should quit, the

AutoLite system will not be available however, with the optional battery attached the stove can be manually lit and operate on battery power for several days (depending on battery size).

START-UP AND OPERATION

Wa rning: Th is stove inco rporates a hop per lid safety switch. The feed system will remain in-operable when the door is open.

Priming the feed system

W hen the stove has run out of fuel the feed systems requires several start and stop cycles to charge the auger.

Pushing the Low button from Off will start the feed for 90 seconds. W hen the feed stops cycle to Off then back to Low for another 90 seconds. W hen pellets begin to fall in the burn pot switch to Off. You are now ready to start the stove.

1.

AutoLite Start-Up:

Prior to operating your AutoLite stove, make sure the hopper is full of wood pellets and the interior components have been installed properly including; burn screen & pot, heat excha nge cove rs, and ash dra wer.

IMPORTANT: The Fire Pot must be seated flush and must sit even in the pot tray. Air leaking around the Fire Pot will create a poor burn (Figure 3). Light the pellets in Fire

Pot using any approve d pellet lighter.

Figure 1 1 Ho pper sa fety sw itch-close lid to op erate

AUTOLITE OPERATION

Your EASYFIRE Pellet Stove is equipped with the

Autolite Automatic ignition and operating system.

The AutoLite system is integrated into the stove to allow for au tom atic sta rt up usin g a heatin g elem en t loc ate d in the b urn p ot. This ele m ent s tarts th e initial fire req uired to burn the wood pellets. The system operates on 120VAC power su pplied through a sepa rate fuse and run s for five m inutes during the initial stove start up. After the five minute period the AutoLite system is deactivated and the

Figure 12

Note: Caution must be taken when installing burn pot or operating door not to damage ceramic glass. Do not atte m pt to op erate he ater if glas s be com es d am aged in any w ay!

5

2.

AutoLite Control Functions: Control functions on the

Easyfire are as follows: OFF, FAN, LOW , MEDIUM, HIGH,

CLEAN. Here is how each function works:

A. W hen the Control Button is turned to FAN , a tim er is activa ted a nd you will have abo ut twe nty (20) m inutes to get the pellets lit and reach a minimum tem perature.

This function is used for match lighting when the AC pow er is out.

Should the pellets not light in 20 minutes simply turn the button to OFF and begin again. This will give you another cycle to get the pellets lit. The reason for the timer function is so that the heater will automatically shut down if the fire goes out. Pellets do not feed in the FAN position.

B. In the LOW position, the EASYFIRE will be feeding approximately 1 to 1½ lbs. of pellets per hour and the flam e will fluctu ate b etwe en 1 " and 6" in he ight.

C. In the MEDIUM position the EASYFIRE will be feeding approximately three (3) pounds of pellets per hour and the flame will fluctuate between 3" and 8" of fire.

D. In the HIGH position the EASYFIRE will be feeding ap prox im ate ly 4+ lbs. pe r ho ur and th e fla m e w ill fluctuate between 3" and a full flame. The fan speed will increa se acco rdingly as the heate r au tom atic ally adjusts itself based on tem perature inside the heater.

E.

The CL EAN position is to be used only when the heater is not burning and you wish to clean out the accumulated ash in the front of the fire area. See

CLEAN OUT section of maintenance instructions.

F.

After the heater is running for several hours and you wish to turn it off simply press the button to OFF. The heater will continue running until it cools down

and then will automatically shut itself down.

G. REMEMBER: Eac h fee d po sition w ill fluctu ate because the microprocessor is automatically adjusting the feed and air based on temperature. This means the pellet feed rate and flame height will change accordingly based on quality of pellet and heat loss of dwelling.

3. Starting the S tove: Push a Heat Range button (Low or

Med ium is bes t for start up) (Figure 13) and turn the thermostat up to “Ca ll for heat”. Th e sto ve fa n will beg in to ope rate a long with the ignitor c ycle. Afte r abo ut a m inute the pellets will begin to fall in the burn pot. After five m inutes there will be a fire in the burn po t and the stove will begin to heat up. W hen the stove reaches start up operating temperature it will then switch to the control panel setting and begin it’s automatic operation cycle.

Feed Trim Adjustment

Underneath the control button you will find a small round button that will turn forward and reverse. This button can adjust the feed motor in the LOW operating position. By turning the button clockwise you can increase the feed on

LOW and by turning it counterclockwise you can decrease the feed in the LOW position. Factory setting is 9:00 o’clock.

Once the stove is at operating temperature for one hour set the stove on LO W. Adjust the trim button so that av erag e flam e is app rox . 1-2" abo ve the bu rn p ot. T his will set the average feed rate (air/flue) for best operation.

M ove this button carefully! It is designed to fine tune your

LO W setting in the e ven t you ch ang e bra nds of pe llets and/or live at a higher elevation. If this setting is to low the sto ve m ay go out d uring LO W setting operatio ns . If th is sho uld ha ppe n incr eas e the trim by sm all am oun t.

MATCH LIGHT FIRE AND START-UP

1.

Filling the Hopper and Start-Up:

CAUTION: FUEL HOPPER LID MUST BE CLOSED

BE FO RE OP ER ATIN G U NIT . MAIN TAIN HO PPE R S EAL

IN GOOD CO NDITIO N. DO NO T OVE RFILL HO PP ER !

THE EASYFIRE WILL HOLD ABOUT 60 LBS. OF

PELLETS.

Open the top lid and fill the hopper with pellets (Figure 11).

Make sure hopper lid is fully closed. Open the front door and fill the burn pot with a hand full of pellets.

Figure 13

Prior to stove operating on therm ostat, confirm proper operation by servicing and adjust ing the stove as outlined in the “Installation Guide”. When servicing stove, operate with thermostat bypassed as stove will reset to sta rt up mod e ea ch tim e th erm ostat is activated.

Figure 14

IMPORTANT: The fire pot must be seated flush and must sit even in the pot tray. Air leaking around the fire pot will create a poor burn (Figure 14). Light the pellets in Fire

Pot using any approve d pellet fuel starter.

6

Allo w p ellets to burn for approx im ate ly 1 m inute, o r un til pellet ign ition has be en a chieved . Clo se d oo r and turn the control knob to the "FAN" position. Allow fire to burn for several minutes. W hen the pellets are well lit, turn the control knob to "L OW " for approximately 10 minutes then turn up to "HI". W e recomm end that you run the heater on

“Medium” or "HI" for about 30 minutes in order to get the

he at e xc ha ng er hot be fore turning it to "LO W ". Yo u w ill need to burn the heater for a few hours before deciding which setting is best for your particular needs.

NOTE: CAUTION M UST BE TAKEN W HEN

INSTALLING BURN POT OR OPERATING DOOR NOT

TO DAMAGE CERAMIC GLASS. DO NOT ATTEMPT TO

OPERATE HEATER IF GLASS BECOM ES DAMAGED

IN ANY WAY!

CAUTION: BOTH TH E MAIN DOOR AND TH E ASH

DRAWER MUST BE PROPERLY ADJUSTED AND

FULLY CLOSED TO FORM AN AIR-TIGHT SEAL FOR

PROPER STOVE OPERATION. FAILURE TO SECURE

DOOR AND DRAWER MAY CAUSE OVER FEEDING

AND HIGH TEMPER ATURE SHUT DO WNS.

DO NOT USE GRATES OR OTHER METHODS OF

SUPPORTING FUEL IN BURN POT OR INTERIOR OF

STOVE.

2.

Control Functions: Control functions on the Eas yfire are as follows: OFF, FAN, LOW , MEDIUM, HIGH,

CLEAN. Here is how each function works:

A. W hen the Control Knob is turned to FAN , a tim er is activa ted a nd you will have abo ut ten (10) m inutes to get the pe llets lit and re ach a m inim um tem pera ture.

Sh ou ld th e pellets n ot lig ht in the 10 m inutes sim ply turn the knob to OFF and begin aga in. This will give you another 10 minutes to get the pellets lit. The reas on for the tim er fun ctio n is so tha t the heate r will automatically shut down if the fire goes out. Pellets do not feed in the FAN position.

B. In the LOW position, the EASYFIRE will be feeding approximately 1 to 1½ lbs. of pellets per hour and the flam e will fluctu ate b etwe en 1 " and 6" in he ight.

C. In the MEDIUM position the EASYFIRE will be feeding approximately three (3) pounds of pellets per hour and the flame will fluctuate between 3" and 8" of fire.

D. In the HIGH position the EASYFIRE will be feeding ap prox im ate ly 4.5 lbs. pe r ho ur and th e fla m e w ill fluctuate between 3" and a full flame. The fan speed will increa se acco rdingly as the heate r au tom atic ally adjusts itself based on temperature inside the heater

(see G below).

E.

The CL EAN position is to be used only when the heater is not burning and you wish to clean out the accumulated ash in the front of the fire area. See

CLEAN OUT section of maintenance instructions.

F.

After the heater is running for several hours and you wish to turn it off simply turn the knob to OFF. The heater will continue running until it cools down

and then will automatically shut itself down.

G. REMEMBER: Eac h fee d po sition w ill fluctu ate because the microprocessor is automatically adjusting the feed and air based on temperature. This means the pellet feed rate and flame height will change accordingly based on quality of pellet and heat loss of dwelling.

DISPOSAL OF ASHES

To dum p ash from firebox, move lever to left several times allowing spring to return against stop (Figure 10 & 11).

Once ash box is full, box should be placed in a nonco m bu stib le flo or or o n th e groun d, w ell awa y fro m all combustible materials pending final disposal. If the ashes are disp os ed of b y burial in soil or othe rwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.

OPTIONAL 12V HOOK-UP & OPERATION

1.

The EASYFIRE 12V back up can be purchased as an option and includes the following components:

a. Dee p cycle sealed 12V batter y.

b. Battery connector cables for ho ok-up to the he ater.

2.

In order to hook-up the battery and engage the 12V backup system sim ply connect red cable to red terminal on the heater (see Figure 6) and to positive connector on battery [the terminal marked (+)] and connect the black c able to the b lack term inal on the heate r and to the negative connector on the battery (the terminal marked (-). If you hook up the cables backwards the red

LED light abo ve the term inal rec epta cles will com e on . If hooked up properly this LED will glow green.

WARNING - MAKE SURE RED CABLE GOES TO RED

TERMINAL (POSITIVE CONNECTOR) AND BLACK

CABLE GOES TO BLACK TERM INAL (NEGATIVE

CO NN ECT OR ).

3.

If you decide to purchase your own 12V back up system we reco m m end a se aled gel ce ll battery. Fa ilure to install the prop er ba ttery cou ld cau se p hysica l harm to you and your property and will also void the heater wa rra nty.

4.

W hen the battery is properly connected and the heater plugg ed in, th e fo llow ing will hap pe n auto m atic ally:

a. The heate r will autom atic ally switc h to 12V p ow er if there is a power failure, and switch back when power is restored.

b. The battery will be trickle charged as long as the heater is plugged into 110 AC wall outlet. Do not use extension cords. The trickle charge will not recharge a low or dead battery but it will keep a charged battery at maximum performance.

5.

If you choose to separate the battery from the heater by lengthening the cables you must m ake sure that the cable wire used will carry the current to the heater. For example, if the distance is 10 to 20 feet then 12 gauge wire must be used. Check with your local electrical professional to mak e sure you have used the proper gauge wire/cable.

CANADIAN REQUIREMENTS

If this unit is being installed in Canada, the following add itional req uirem ents m ust b e m ean t:

1.

A chimney connector shall no pass through and attic or roof space , closet or similar concealed spa ce, or a floor, or ceiling.

2.

W here a chimney passage through a wall, or partition of co m bu stib le con struc tion is des ired, th e insta llatio n sha ll conform the CAN/CSA-B365.

3.

Maintain an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure by sealing with high temp erature silicone.

7

4.

Clearance to combustibles may only be reduced by m ea ns approved by th e re gu lato ry au tho rity.

5.

Store pellet fuels in a dry area away from unit. Do not store fuels within the space heater installation clearances or within the space required for charging an d ash rem oval.

6.

Ad eq ua te ven tilatio n air is req uired to o pe rate th is heater. During operation the heater draws air for combustion which can be assisted by the installation of outsid e com bu stio n air inle ts. Ho we ver, certain weather conditions such as icing or use of kitchen exhaust fans may impact and reduce the effectiveness of vents. It is important to note that room air starvation well negatively impac t the operation of the heater.

a. Open door and remove clean out slide cover. To rem ove, s im ply slide up and out from retaining angle brac ke t (Figure 10). Clea n on e side at a tim e. W ith one slide cover rem oved, leave door ope n and turn control knob to the "CLEAN" position. Let heater run until ash in fire pot area is vacuumed out by heater fan. Turn off and replace cover. Rem ove remaining cover and repeat procedure for the other side. The tee cap on the vent pipe should be cleaned out after this procedure.

b. Rem ove firepot by lifting up and out, it may be brushed out or vacuumed. Firepot should be cleaned daily. Make sure holes in pot are not clogged. The area around and below the pot should be checked every five or six days depen ding on how m any hours a day you are burning your heater and the quality of the pellets being burned . (After a few days you w ill be able to determine the frequency needed for clean out.)

Figure 15

7.

If pow er outag es with batter y back up or roo m air sta rva tion occu rs during ope ration of h ea ter, sm ok e in the house may result. This may trigger smoke detectors if they are installed.

MAINTENANCE PROCEDURE

CAUTION: MOVING PARTS MAY CAUSE INJURY, DO

NOT OPERATE WITH REAR COVER REMOVED.

WARNING: RISK OF ELECTRICAL SHOCK,

DISCONNECT ALL POWER BEFORE SERVICING.

ALWAYS TURN YOUR Heater OFF & LET IT COOL

BEFORE CLEANING.

So ot a nd Fly-a sh: Fo rm atio n an d N eed for R em ov al.

The products of combustion will contain small particles of fly-ash. The fly-ash will collect in the exhaust venting system and restric t the flow of the flue gase s. Inc om plete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at le as t on ce every year to determ ine if cle an ing is necessary.Your EASYFIRE Pellet Heater requires routine m aintenance for m axim um perform ance an d is ma ndatory for the warranty to remain in effect. The following procedures should be studied carefully and performed regularly as indicated:

1.

Fly Ash: Some ash will accumulate in the heat exchanger, firepot and flue and should be cleaned out on a regu lar basis fo r bes t efficien cy and sa fety.

W hen the heater is shut down and cold, you should:

Figure 16

c. Scrape pellet feed chu te with putty knife to rem ove hardened material on which sawdust can accumulate.

d. The tee connector on the vent pipe must have a clean ou t cap and this m ust b e ch eck ed e very four to six weeks or whenever you utilize the clean out mode on the control dial.

8

Figure 17

e. Fly-ash can also accumulate in the vent pipe. Inspect exhaust system frequently to maintain free flow of exhaust fumes and fly-ash. The frequency of cleanout depends entirely on the quality of the pellets, so you will have to initially monitor the buildup in the pellet vent pipe. Those installations going into an

existing flue must be installed with a tee connector (Figu re

3,4,& 5) to allow access to clean the ash from the pellet vent pipe.

Figure 18 Air box clean out, air damper adjustment f.

Fly-ash will accum ulate below the burn pot. Rem ove the air box clean out and depose of ash. Use care not m ove air dam per s etting.

2.

Hop per Clean Ou t: Vacuum the accumulated saw dust in the hopper weekly. Keep free of debris and foreign material. AN ACCUMU LATION OF SAW

DUST CAN CA USE IRREG ULAR PELLET FEED. For be st res ults this shou ld be don e on a reg ular ba sis depending upon how often the heater is used. If you burn the heater all the tim e you should do this every eight to ten days.

3.

Cleaning the Exhaust Fan Blade & Heat Exchang-

er: The exhaust blower should be checked for excessive fly ash buildup. Regular and routine maintenance utilizing the CLEAN OUT feature will keep the ex ha us t blo we r ho us ing and fa n blades clean . This cleaning can only be done when the heater is NOT burning. For best results run the fan in the CL EAN

OUT position with the door open for approx im ate ly one minute or until ash is no longer being picked up by the fan. Remem ber, you must always check the clean out cap on the tee after utilizing the CLEAN OUT feature.

4.

Keeping the Glass Clean: If soo t dep osits accumulate on the glass, clean with window glass cleaner and a paper towel when the glass is cold.

5.

Polishing the Gold and Chrom e: All chrome and gold plating used on the EASYFIRE heater can be cleaned with a soft cloth and non -abrasive cleaner.

6.

Cleaning & Polishing Gold Plated Parts: Gold is a soft metal and therefore a fragile surface. Prior to the firs t bu rn it is im po rtant to use W index or c om pa rable prod uc t an d a soft clean cloth to w ipe any m arks off all gold surf ace s or th e he at will cau se th e m ark s to remain in the surface permanently. Always clean the gold surface when the heater is COO L.

7.

Doo r glass replace me nt: Should the door glass become broken it may be replaced by scraping the sealer from around the outer edge of the glass.

Carefully pry gla ss fro m door fra m e th en clean all sealer from frame. Obtain a replacement glass from your local dealer and attach glass to door using High

Tem pe rature S ilcon S ea ler (m in. 4 00 deg.F ). App ly sea ler to all fou r corners of the glass and set g lass into

9 frame. Apply sealer to mating edge of glass and frame.

Allow two h ours dry tim e be fore installing d oor o nto hea ter. Note : Replac e w ith Pyro-Ce ramic G lass only.

Refer to parts list for specifications.

TROUBLE-SHOOTING

The following scenarios are provided in order to help you locate a difficulty if the heater performs in a manner which would seem to indicate a malfunction: l.

P ro ble m : I loaded the h eater for start-up, lit the fire starter and pellets but the fire didn't keep going.

Solution: Ch eck pow er co rd to s ee th at it is plugg ed in.

Rem ember that the timer on start up runs about 10 m inutes and if the he ater h as n ot he ated up e nou gh to deactivate the timer you will have to start over by turning the knob to off and then back to FAN or LOW.

The EASYFIRE will automatically switch to 12 volt backup provided you have the 12 volt option installed.

2.

P ro ble m : The heater was lit and burning properly, then suddenly it stopped feeding pellets.

Solution: a) C he ck pellet s up ply in hopp er. If em pty, fill and follow start-up procedure as outlined in the beginning of this manual. b) Occasionally, a foreign object, debris or an excessive amount of sawdust can en ter the fee d m ec ha nis m and ja m the fee d chu te. If this happens, you must em pty the hopper and check the feed chute to see what is causing the jam. Rem ove any foreign m aterial or object and re-start the heater.

CAUTION: Keep fingers and hands clear of feed mechanism when heater is on.

3.

P ro ble m : Th e fire w as b urnin g we ll and the n it beg an to overfeed pellets and started backing up into the pellet feed chute, smothering the fire.

Solution: W he n th e pellets a re overfeed ing, it us ua lly means that the air flow has been reduced. Check the firepot air intake holes to be sure they are clear. Check to se e if firepot wa s pro perly se ated in pot tra y. Che ck to see if the manifold may have filled with fly ash. If you use a low grade pellet, and clinkers (fused ash and dirt) form in the bottom of the firepot, it will choke the air intake

(you might consider changing the brand of pellets to one that burns cleaner). You m ust let the fire go out before rem oving and clean ing the firepo t.

Ne ve r va cuum ou t the hea ter w hen th e he ater is in operation! The hot ashes can lodge in your vacuum cleaner and cause a fire!

You m us t cle an the m an ifold and air b ox reg ularly in order to insure a good air to fuel ratio, thus allowing the heater to "breathe" properly. You must also check the vent pipe and tee to see that they are not clogged and full of ash.

4.

P ro ble m : Heater was burning well and then soot began form ing on the glass door.

Solution: Black soot forming on the glass door means that the combustion is not right and the heater needs a good clean out. Some brands of pellets burn much richer than others and you might have to change brands of pellets and/or have the air/fuel settings re-adjusted by your dealer. It is normal to have the glass cloud up after several hours of burning but it should wipe off with a go od win do w c leane r. If the glass turns black quick ly, then the heate r nee ds a goo d clea n ou t.

5.

P ro ble m : W e had a power failure and the heater emitted smok e for about five minutes.

Solution: If the heater emits smoke during a power failure, and you have frequent power failures then we sug ges t you pu rchase the battery ba ck -up s ystem . If the vent pipe is installed according to these ins tructio ns the sm ok e w ill sypho n out o f the pipe in most instances.

6.

P ro ble m : After several week s of outstanding performance, the heater suddenly stopped and the red light under the control knob came on. This light is the Hi

Te m p/Flu e Ind icator Light.

Solution: The Hi-Temp/Flue Indicator light indicates that fly ash has built up in the exhaust system and/or there is a restriction in the exhaust/flue system. Check the pipe system for excessive ash and clogging, particularly the vent cap. Remove the clean out cap on the tee and make sure that ash has not blocked the exhaust air flow. This automatic shut down in case of flue clogging is a safety feature and if the shut down oc cu rs it m ea ns you have a problem and sho uld consult a service technician and/or clean your pipe an d hea ter tho roug hly. If you fee l the fly as h build up is exc ess ive, we sug ges t that you try anoth er brand . In m ois t clim ate s th e pellets a nd fly as h can actua lly absorb moisture from the air and create creosote and a severe clogging problem. Keep this in mind when you store a nd h and le your p ellets. T he h eate r warran ty does not cover the quality of the fuels used or the way they may be ha ndled either before or after you've purchased them.

7.

P ro ble m : I pres s a “Run ” bu tton and th e hea ter did not s tart.

Solution: Check for AC power. The autolite system requ ires 110 V A C powe r to operate . If hea ter only

12V DC battery pow er, follow m anu al light pro ced ure. If

AC power is available, clean burn pot for heavy ash deposit. Heavy ash deposits will act as insulator and not allow pellets to light. Check autolite fuse located on fuse panel to confirm fuse is not blown. Replace fuse with 5 am p if req uired .

8.

P ro ble m : I started to add pellet fuel and the heater wen t out.

Solution: The heater incorporates a safety switch that will disable the feed system when the hopper door is ope n. If fue l is to be adde d w hile heate r is in operation it must be accomplished with in several m inutes of opening the doo r.

9.

P ro ble m : I turned off the switch and the heater kept running.

Solution: Th is is norm al. T he exha us t blo we r will ke ep run ning until it c oo ls dow n and the n it w ill automatically turn off. This can vary by the temperature the exhaust has reached and the temperature of the cooling air.

Figure 19 Feed system access through hopper

10. P ro ble m : Feed system jam med.

Solution: This condition is caused by fuel contaminated with hard materials such as rocks or metal objects. To correct this remove all pellets from hopper. Unplug heater from any power sou rce (12V & 110V). Re m ove the (4) nuts with a 3/8" nut driver attaching acces s cover.

Carefully remove cover and vacuum out remain pellets.

Locate the object jamm ing auger and reassemble. Plug hea ter into p owe r sou rce and pus h “R un” b utton . W ith hopper door open, press safety switch down and view au ge r op eratio n. If auge r turns freely add fue l. An d prim e fuel system.

HI TEMP/FLUE AND TRIM INDICATORS:

W hen the H i-Te m p/Flu e indic ator ligh t com es o n (red lite beneath control knob) it means that the flue is obstructed or you have a re verse draft and gase s c an no t ex it prop erly.

Maintenance is required and a thorough cleaning and pipe check m ust be perform ed. (Check to ma ke su re that the left and right clean out covers were installed properly, this can cause a Hi-Tem p indication)

TRIM button : Underneath the control knob you will find a sm all ro un d butto n th at w ill turn fo rward and rev erse . This button can control the feed motor rate. By turning the button clo ck wis e you can increas e th e burn ra te a nd by tu rning it co un terclo ck wis e you can decrea se the burn rate. U se this to change the overall rate for different pellets. For instance, if the pellet ha s high ash and burns dirty dec reas e th e "trim " and if the heater goes out on low or has low flame increase the "trim ".

M ove this button carefully! It is designed to fine tune your

LO W setting in the e ven t you ch ang e bra nds of pe llets and/or live at a higher elevation.

Cus tom er Service & Rep lacem ent Parts

Replacement parts are available from your local dealer or on-line @ ww w.s ierrap rodu ctsinc.ne t . Our call or write:

Customer Service

Sierra Products, Inc.

5061 Brooks St., Ste. B, Montclair, CA 91763

Phone 1-909-399-3355 x21

Fax 1-909-399-3357 www.sierraproductsinc.net

`

ITEM No.

8

9

10

11

12

13

14

6

7

4

5

1

2

3

15

16

17

18

PART NUMBER

110541

110429

100125

110451

300522

200549

300500

120117

202164

120120

120118

120114

10475

110070

300536

300544

110524

100126

DESCRIPTION

HOPPER LID SAFETY SWITCH

DOOR GLASS (CERAMIC 11"x11 3/4"x5mm)

DOOR GASKET, WOVEN FIBER

ASH DUMP KNOB

ASH DRAWER

HEAT EXCHANGE COVER

FIREPOT - AL V2

AUTOLITE IGNITER

BURN POT SCREEN - AL

AUTOLITE POWER RELAY

AUTOLITE PUSH BUTTON SWITCH

MAIN CONTROL BOARD V2.2 -A L

COMBUSTION/CONVECTION FAN ASSY.

CONVECTION FAN BLADE

V3 FEED MOTOR ASSEMBLY

V3 AUGER/SHAFT ASSEMBLY

FEED SHAFT BUSHINGS (2)

HOPPER LID GASKET (NOT SHOWN)

5061 Brooks St., Ste. B Montclair, CA 91763

Phone 1-909-399-3355 Fax 1-909-399-3357 www.sierraproductsinc.net

P/N 140661r3 02/08