Westermo Viper 008 is a rugged and reliable unmanaged Ethernet switch with 8 ports, designed for harsh industrial and rail applications. It features a sturdy metal housing with IP65 protection, making it resistant to dust, water, and extreme temperatures. With its wide input voltage range of 24 to 110 VDC, the Viper 008 can be easily integrated into existing power systems.
advertisement
User Guide
6641-2211
Viper
0 0 8
Unmanaged 8-port
Ethernet Switch
www.westermo.com
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address: http://www.westermo.com
2 6641-2211
Safety
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.
The power supply wiring must be sufficiently fused (e.g. Littlefuse 0461 1.25), and if necessary it must be possible to disconnect manually from the power supply. If fault contact is used, make sure that fault contact wiring is sufficiently fused.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section).
!
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Do not cover or bring mechanical force to the ventilation membrane on the back of the unit.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
6641-2211 3
4
Agency approvals and standards compliance
Type
EMC
Safety
Approval / Compliance
EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 55024, Immunity IT equipment
EN55022, Emission IT equipment
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50155 Railway applications - Electronic equipment used on rolling stock
EN 50121-3-2, Railway applications - EMC: Rolling stock – Apparatus
FCC part 15 Class B
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
EN 60950-1, IT equipment
FCC Part 15.105 Notice: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna
… Increase the separation between the equipment and receiver
… Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
6641-2211
Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The manufacturer Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
Type of product
Ethernet switch
Model
Viper switch
Art no
3641-0360,
3641-0350,
3641-0340 is in conformity with the following EC directive(s).
No Short name
2004/108/EC
2006/95/EC
Electromagnetic Compatibility (EMC)
Low Voltage Directive - LVD
References of standards applied for this EC declaration of conformity.
No
EN 55022
EN 55024
EN 61000-6-1
EN 61000-6-2
Title
Information technology equipment – Radio disturbance characteristics - Limits and methods of measurement
Information technology equipment - Immunity characteristics -
Limits and methods of measurement
Immunity for residential, commercial and light-industrial environments
Immunity for industrial environments
EN 61000-6-3
EN 61000-6-4
EN 50121-3-2
Issue
2006
+A1:2007
1998
+A1:2001 +A2:2003
2007
Emission standard for residential, commercial and light-industrial environments
Emission standard for industrial environments
Railway applications - Electromagnetic compatibility
2005
2007
2007
2006
2006 EN 50121-4 Railway applications - Electromagnetic compatibility - Part 4:
Emission and immunity of the signaling and telecommunications apparatus
Safety of information technology equipment EN 60950-1 ♣
The last two digits of the year in which the CE marking was affixed:
2006
09
Pierre Öberg
Technical Manager
28th October 2009
♣ Note: Manual and safety instructions are only in English
Postadress/Postal address
S-640 40 Stora Sundby
Tel.
016-428000
Telefax
016-428001
Sweden Int+46 16428000 Int+46 16428001
6641-2211
Postgiro
52 72 79-4
Bankgiro
5671-5550
Org.nr/
Corp. identity number Registered office
556361-2604 Eskilstuna
5
Type tests and environmental conditions
Phenomena
ESD
RF field AM modulated
Fast transient
Surge
RF conducted
Test
EN 61000-4-2
IEC 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Power frequency magnetic field
EN 61000-4-8
Pulse magnetic field EN 61000-4-9
Voltage dips and interruption EN 50155
Radiated emission
Conducted emission
Dielectric strength
Temperature
Humidity
Service life
Vibration, random simulated long life
EN 55022
FCC part 15
EN 55022
FCC part 15
EN 50155
Altitude
Reliability prediction (MTBF) MIL-C217F2
IEC 60068-2-64,
Cat. 1 class B
(EN 61373)
Vibration, random functional IEC 60068-2-64,
Cat. 1 class B
(EN 61373)
Description
Enclosure contact
Enclosure air
Enclosure
Ethernet ports
Power port
Earth port
Fault port
Ethernet ports
Power port
Ethernet ports
Power port
Enclosure
Enclosure
DC power ports
Enclosure
DC power port &
Ethernet ports
DC power port
Ethernet ports to other isolated ports
Power & Fault port to other isolated ports
Operating
Storage & Transport
Operating
Storage & Transport
Operating
Operating
Operating
Not Operating
Operating
Test levels
± 6 kV (crit A)
± 8 kV (crit A)
20 V/m 80% AM (1 kHz),
80 – 2500 MHz (crit A)
± 2 kV (crit A)
± 2 kV (crit A)
± 2 kV (crit A)
± 2 kV line to earth (crit A)
± 2 kV line to earth (crit A)
± 2 kV line to earth, ± 2 kV line to line
(crit A)
10 V 80% AM (1 kHz), 0.15 – 80 MHz
(crit A)
10 V 80% AM (1 kHz), 0.15 – 80 MHz
(crit A)
1000 A/m 50 Hz
300 A/m 16.7 Hz, 60 Hz, DC (crit A)
300 A/m (crit A)
10 ms, interruption (crit A)
100 ms +- 40 % above/below rated voltage (crit A)
Class B
Class B
Class B
Class B
707 VDC 1 min
2121 VDC 1 min
–40 to +70ºC
–40 to +70ºC
5 to 95% relative humidity
5 to 95% relative humidity
2000 m / 70 kPa
Ground Benign:
150 years @ 20 ºC
147 years @ 40 ºC
135 years @ 60 ºC
Ground Mobile:
9,87 years @ 20 ºC
9,85 years @ 40 ºC
9,79 years @ 60 ºC
Ground Fix:
28,54 years @ 20 ºC
28,43 years @ 40 ºC
27,95 years @ 60 ºC
10 year
Vertical: 7.9 m/s 2
Transverse: 7.9 m/s 2
Longitudinal: 7.9 m/s 2
3 x 5 h
Vertical: 1.0 m/s 2
Transverse: 1.0 m/s 2
Longitudinal: 1.0 m/s 2
3 x 10 min
6 6641-2211
Phenomena
Shock, half sine pulses
Shock, sawtooth
Enclosure
Dimension W x H x D
Weight
Degree of protection
Cooling
Mounting
Test
IEC 60068-2-27,
Cat. 1 class B
(EN 61373)
Description
Operating
IEC 60068-2-27,
Cat. 1 class B
(IEEE1478-2001)
Operating
UL 94 Nickel coated zinc
IEC 529 Enclosure
Test levels
Vertical:
Transverse:
Longitudinal:
30 ms, 3 x 6 shocks
50 m/s 2
50 m/s 2
50 m/s 2
Vertical: 100 m/s 2
Transverse: 100 m/s 2
Longitudinal: 100 m/s 2
11 ms, 3 x 6 shocks
Flammability class V-1
175 x 100 x 53,4 mm
1 kg
IP 65 when all ports are protected/ connected else IP 40
Convection
DIN Rail or wall mounted
6641-2211 7
Description
Functional description
Viper 008 is a unmanaged switch developed for rail and industrial applications. To meet the environmental requirements from rail and harsh industrial applications the switch has rugged M12 Ethernet connectors and full metal housing. The IP65 sealed metal case make it robust and allows for the surrounding air temperature to be between –40 to
+70°C. There are no sensitive or fragile components, hardening the product against shock and vibration making these units suitable for rolling stock usage. The power supply operates over a wide input range from 24 to 110 VDC.
8 6641-2211
Interface specifications
Power and fault relay port PWR
Rated voltage 24 to 110 VDC
Operating voltage 24 to 110 VDC ±40%
Rated current
Rated frequency
Inrush current, I
Polarity
Shielded cable
2
Fault relay resistance
Operating voltage t
Redundant power input
Isolation to
Connection
Connector size
30 mA @ 110 VDC
90 mA @ 24 VDC
DC
Max 0.02 A 2 s @ 24 – 110 VDC
Reverse polarity protected
No
Connections X1 – X8 and to ground, 1500 VAC.
Fault relay belongs to the same isolation group as the power supply lines (fault relay signals are also contained within
PWR).
4 pin male M12 connector with A-code
M12, recommended cable area 0.5 mm 2 recommended
(minimum 0.25 mm 2 ), cable dimensions depend on choice of
M12 connector
Not required, twisted pair is recommended
< 10 Ω
Up to 110 VDC
Position Direction Description
1 U+ Positive supply voltage
2 Out Alarm relay (status) +
M12 A-Coded
Power
Connector
3
4
Housing
0 V
Out
Shield
Negative supply voltage
Alarm relay (status) –
Chassis of product (ground)
6641-2211 9
Fault Contact
The Viper switch is equipped with a potential free normally closed fault contact.
The fault contact is a solid state component (relay) that requires power to work and it is transient protected. Additionally, the fault contact is opened when any of the following conditions is met:
• No voltage on the power supply pin, a voltage level outside the legal voltage range or current limitation on the voltage source is applied on the power input.
Description of how connection to the fault contact could be done is shown below.
The relay is closed when the unit is OK and open at failure. The relay is of semiconductor type (no moving parts). It is specified for max current 250 mA continuous,
500 mA peak (10 ms), operational voltage up to 110 V, protected by a 150 VDC-varistor,
ON-resistance less than 10 Ohm, and leakage current max 1 µA.
Viper
External relay
2
+24/48 VDC
4
Viper
To logic input
2
4
+
1 kΩ
Input on PLC
0V
Service port
The Service Port should not be used by non other than the Westermo Technical Support team. Do not connect any device or cable to the Service Port.
10 6641-2211
Ethernet TX port X1 to X8
Electrical specification
Data rate
Duplex
Circuit type
Transmission range
Isolation to
Galvanic connection to
Connection
Shielded cable
Conductive housing
IEEE std 802.3. 2005 Edition
10 Mbit/s or 100 Mbit/s
Full or half
TNV-1
100 m
Other Ethernet ports, 500 VAC
PWR, 1500 VAC
None, except for shielded contact to housing
4-pole M12 female with D-code
Not required, twisted pair is recommended
Nickel plated zinc, metal housings of X1-X8 also connected to the housing
8 Ethernet (X1-X8)
Number of ports
Position Direction Description
1 Out Transmit Data +
2
3
4
In
Out
In
Receive Data +
Transmit Data –
Receive Data –
Housing Shield Chassis of product (ground)
6641-2211 11
Location of Interface ports, LED's
LED indicators
LED
PWR
X1 to X8
Status
GREEN
RED
OFF
GREEN
GREEN
FLASH
Description
Unit indicates no fault
Unit indicated fault
No Link
Link is up
Data is transmitted
SERVICE
X3
X1
X2
X7
X5
X6
PWR X4 X8
12 6641-2211
Mounting, DIN-rail
This unit can be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. Snap on mounting, see figure.
Removal
Press down the support at the back of the unit using a screwdriver. See figure.
6641-2211 13
Wall mounting
There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M6 screws with 12 mm washer on a flat and stable surface.
SERVICE
X3
X1
X2
X7
X5
X6
PWR X4 X8
Removal
Disconnect all cables and unscrew the unit from the wall.
Cooling
This unit uses convection cooling. Avoid obstructing the airflow around the unit. Spacing is recommended for the use of unit in full operating temperature range and service life.
14 6641-2211
Dimensions
Measurements are stated in millimeters.
6641-2211 15
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden
Phone +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: [email protected]
Westermo Web site: www.westermo.com
Westermo Data Communications AB
Svalgången 1
SE-724 81 Västerås
Phone: +46 (0)21 548 08 00 • Fax: +46 (0)21 35 18 50 [email protected]
Westermo Data Communications Ltd
Talisman Business Centre • Duncan Road
Park Gate, Southampton • SO31 7GA
Phone: +44(0)1489 580-585 • Fax.:+44(0)1489 580586
E-Mail: [email protected]
Westermo Data Communications GmbH
Goethestraße 67, 68753 Waghäusel
Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9
E-Mail: [email protected]
Subsidiaries
Westermo Data Communications S.A.R.L.
9 Chemin de Chilly 91160 CHAMPLAN
Tél : +33 1 69 10 21 00 • Fax : +33 1 69 10 21 01
E-mail : [email protected]
Westermo Data Communications Pte Ltd
2 Soon Wing Road #08-05
Soon Wing Industrial Building
Singapore 347893
Phone +65 6743 9801 • Fax +65 6745 0670 [email protected]
Westermo Teleindustri AB have distributors in several countries, contact us for further information.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project