The contents of this document are provided “as is”. Except as required by applicable  law, no warranties of any kind, either express or implied, including, but not limited to,  the implied warranties of merchantability and fitness for a particular purpose, are made  in relation to the accuracy and reliability or contents of this document. Westermo  reserves the right to revise this document or withdraw it at any time without prior  notice.

Under no circumstances shall Westermo be responsible for any loss of data or income  or any special, incidental, and consequential or indirect damages howsoever caused.

More information about Westermo can be found at the following Internet address: http://www.westermo.com

2 6641-2211

Safety

!

Before installation:

Read this manual completely and gather all information on the unit. Make sure that  you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. 

This unit should only be installed by qualified personnel.

This unit should be built-in to an apparatus cabinet, or similar, where access is  restricted to service personnel only.

The power supply wiring must be sufficiently fused (e.g. Littlefuse 0461 1.25), and  if necessary it must be possible to disconnect manually from the power supply. If  fault contact is used, make sure that fault contact wiring is sufficiently fused.

This unit uses convection cooling. To avoid obstructing the airflow around the unit,  follow the spacing recommendations (see Cooling section).

!

Before mounting, using or removing this unit:

Prevent access to hazardous voltage by disconnecting the unit from power supply.

Warning! Do not open connected unit. Hazardous voltage may occur within this  unit when connected to power supply.

Care recommendations

Follow the care recommendations below to maintain full operation of unit and to fulfil  the warranty obligations.

This unit must not be operating with removed covers or lids.

Do not attempt to disassemble the unit. There are no user serviceable parts inside.

Do not drop, knock or shake the unit, rough handling above the specification may cause  damage to internal circuit boards.

Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.

Do not paint the unit. Paint can clog the unit and prevent proper operation.

Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.

Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical  part may be damaged.

If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.

Do not cover or bring mechanical force to the ventilation membrane on the back of the  unit.

Maintenance

No maintenance is required, as long as the unit is used as intended within the specified  conditions.

6641-2211 3

4

Agency approvals and standards compliance

Type

EMC

Safety

Approval / Compliance

EN 61000-6-1, Immunity residential environments

EN 61000-6-2, Immunity industrial environments

EN 55024, Immunity IT equipment

EN55022, Emission IT equipment

EN 61000-6-3, Emission residential environments

EN 61000-6-4, Emission industrial environments

EN 50155 Railway applications - Electronic equipment used on rolling stock

EN 50121-3-2, Railway applications - EMC: Rolling stock – Apparatus

FCC part 15 Class B

EN 50121-4, Railway signalling and telecommunications apparatus

IEC 62236-4, Railway signalling and telecommunications apparatus

EN 60950-1, IT equipment

FCC Part 15.105 Notice: This equipment has been tested and found to comply with the limits for a 

Class B digital device, pursuant to Part 15 of the FCC Rules. These limits  are designed to provide reasonable protection against harmful interference  in a residential installation. This equipment generates, uses and can radiate  radio frequency energy and, if not installed and used in accordance with  the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio  or television reception, which can be determined by turning the equipment  off and on, the user is encouraged to try to correct the interference by  one or more of the following measures:

… Reorient or relocate the receiving antenna

… Increase the separation between the equipment and receiver

… Connect the equipment into an outlet on a circuit different from that to  which the receiver is connected

… Consult the dealer or an experienced radio/TV technician for help.

6641-2211

Declaration of Conformity

Westermo Teleindustri AB

Declaration of conformity

The manufacturer Westermo Teleindustri AB

SE-640 40 Stora Sundby, Sweden

Type of product

Ethernet switch

Model

Viper switch

Art no

3641-0360,

3641-0350,

3641-0340 is in conformity with the following EC directive(s).

No Short name

2004/108/EC

2006/95/EC

Electromagnetic Compatibility (EMC)

Low Voltage Directive - LVD

References of standards applied for this EC declaration of conformity.

No

EN 55022

EN 55024

EN 61000-6-1

EN 61000-6-2

Title

Information technology equipment – Radio disturbance characteristics - Limits and methods of measurement

Information technology equipment - Immunity characteristics -

Limits and methods of measurement

Immunity for residential, commercial and light-industrial environments

Immunity for industrial environments

EN 61000-6-3

EN 61000-6-4

EN 50121-3-2

Issue

2006

+A1:2007

1998

+A1:2001 +A2:2003

2007

Emission standard for residential, commercial and light-industrial environments

Emission standard for industrial environments

Railway applications - Electromagnetic compatibility

2005

2007

2007

2006

2006 EN 50121-4 Railway applications - Electromagnetic compatibility - Part 4:

Emission and immunity of the signaling and telecommunications apparatus

Safety of information technology equipment EN 60950-1 ♣

The last two digits of the year in which the CE marking was affixed:

2006

09

Pierre Öberg

Technical Manager

28th October 2009

♣ Note: Manual and safety instructions are only in English

Postadress/Postal address

S-640 40 Stora Sundby

Tel.

016-428000

Telefax

016-428001

Sweden Int+46 16428000 Int+46 16428001

6641-2211

Postgiro

52 72 79-4

Bankgiro

5671-5550

Org.nr/

Corp. identity number Registered office

556361-2604 Eskilstuna

5

Type tests and environmental conditions

Phenomena

ESD

RF field AM modulated 

Fast transient

Surge

RF conducted

Test

EN 61000-4-2

IEC 61000-4-3

EN 61000-4-4

EN 61000-4-5

EN 61000-4-6

Power frequency magnetic  field 

EN 61000-4-8

Pulse magnetic field EN 61000-4-9

Voltage dips and interruption  EN 50155

Radiated emission 

Conducted emission

Dielectric strength

Temperature

Humidity

Service life

Vibration, random simulated  long life 

EN 55022

FCC part 15

EN 55022

FCC part 15

EN 50155

Altitude

Reliability prediction (MTBF) MIL-C217F2

IEC 60068-2-64,

Cat. 1 class B

(EN 61373)

Vibration, random functional IEC 60068-2-64,

Cat. 1 class B

(EN 61373)

Description

Enclosure contact 

Enclosure air

Enclosure

Ethernet ports

Power port

Earth port

Fault port

Ethernet ports

Power port

Ethernet ports

Power port

Enclosure

Enclosure

DC power ports

Enclosure

DC power port & 

Ethernet ports

DC power port

Ethernet ports to other  isolated ports

Power & Fault port to  other isolated ports

Operating

Storage & Transport

Operating

Storage & Transport

Operating

Operating

Operating

Not Operating

Operating

Test levels

± 6 kV (crit A)

± 8 kV (crit A)

20 V/m 80% AM (1 kHz),  

80 – 2500 MHz (crit A)

± 2 kV (crit A)

± 2 kV (crit A)

± 2 kV (crit A)

± 2 kV line to earth (crit A)

± 2 kV line to earth (crit A)

± 2 kV line to earth, ± 2 kV line to line 

(crit A)

10 V 80% AM (1 kHz), 0.15 – 80 MHz 

(crit A)

10 V 80% AM (1 kHz), 0.15 – 80 MHz 

(crit A)

1000 A/m 50 Hz 

300 A/m 16.7 Hz, 60 Hz, DC (crit A)

300 A/m (crit A)

10 ms, interruption (crit A)

100 ms +- 40 % above/below   rated voltage (crit A)

Class B

Class B

Class B

Class B

707 VDC 1 min

2121 VDC 1 min

–40 to +70ºC

–40 to +70ºC

5 to 95% relative humidity

5 to 95% relative humidity

2000 m / 70 kPa

Ground Benign:  

150 years @ 20 ºC

147 years @ 40 ºC

135 years @ 60 ºC

Ground Mobile:  

9,87 years @ 20 ºC

9,85 years @ 40 ºC

9,79 years @ 60 ºC

Ground Fix: 

28,54 years @ 20 ºC

28,43 years @ 40 ºC

27,95 years @ 60 ºC

10 year

Vertical:  7.9 m/s 2

Transverse:  7.9 m/s 2

Longitudinal:  7.9 m/s 2

3 x 5 h

Vertical:  1.0 m/s 2

Transverse:  1.0 m/s 2

Longitudinal:  1.0 m/s 2

3 x 10 min

6 6641-2211

Phenomena

Shock, half sine pulses

Shock, sawtooth

Enclosure

Dimension W x H x D

Weight

Degree of protection

Cooling

Mounting

Test

IEC 60068-2-27,

Cat. 1 class B

(EN 61373)

Description

Operating

IEC 60068-2-27,

Cat. 1 class B

(IEEE1478-2001)

Operating

UL 94 Nickel coated zinc

IEC 529 Enclosure

Test levels

Vertical: 

Transverse: 

Longitudinal: 

30 ms, 3 x 6 shocks

50 m/s 2

50 m/s 2

50 m/s 2

Vertical:  100 m/s 2

Transverse:  100 m/s 2

Longitudinal:  100 m/s 2

11 ms, 3 x 6 shocks

Flammability class V-1

175 x 100 x 53,4 mm

1 kg

IP 65 when all ports are protected/  connected else IP 40

Convection

DIN Rail or wall mounted

6641-2211 7

Description

Functional description

Viper 008 is a unmanaged switch developed for rail and industrial applications. To meet  the environmental requirements from rail and harsh industrial applications the switch  has rugged M12 Ethernet connectors and full metal housing.  The IP65 sealed metal case  make it robust and allows for the surrounding air temperature to be between –40 to

+70°C. There are no sensitive or fragile components, hardening the product against shock  and vibration making these units suitable for rolling stock usage. The power supply operates over a wide input range from 24 to 110 VDC.

8 6641-2211

Interface specifications

Power and fault relay port PWR  

Rated voltage 24 to 110 VDC

Operating voltage 24 to 110 VDC ±40%

Rated current

Rated frequency

Inrush current, I

Polarity

Shielded cable

2

Fault relay resistance

Operating voltage t

Redundant power input

Isolation to

Connection

Connector size

30 mA @ 110 VDC

90 mA @ 24 VDC

DC 

Max 0.02 A 2 s  @ 24 – 110 VDC

Reverse polarity protected

No

Connections X1 – X8 and to ground, 1500 VAC.

Fault relay belongs to the same isolation group as the power  supply lines (fault relay signals are also contained within 

PWR).

4 pin male M12 connector with A-code

M12, recommended cable area 0.5 mm 2  recommended  

(minimum 0.25 mm 2 ), cable dimensions depend on choice of 

M12 connector

Not required, twisted pair is recommended

< 10 Ω

Up to 110 VDC

Position Direction Description

1 U+ Positive supply voltage

2 Out Alarm relay (status) +

M12 A-Coded 

Power 

Connector

3

4

Housing

0 V

Out

Shield

Negative supply voltage

Alarm relay (status) –

Chassis of product (ground)

6641-2211 9

Fault Contact

The Viper switch is equipped with a potential free normally closed fault contact. 

The fault contact is a solid state component (relay) that requires power to work and it  is transient protected. Additionally, the fault contact is opened when any of the following  conditions is met:

•  No voltage on the power supply pin, a voltage level outside the legal voltage range  or current limitation on the voltage source is applied on the power input.

Description of how connection to the fault contact could be done is shown below.  

The relay is closed when the unit is OK and open at failure. The relay is of semiconductor type (no moving parts). It is specified for max current 250 mA continuous,  

500 mA peak (10 ms), operational voltage up to 110 V, protected by a 150 VDC-varistor, 

ON-resistance less than 10 Ohm, and leakage current max 1 µA.

Viper

External relay

2

+24/48 VDC

4

Viper

To logic input

2

4

+

1 kΩ

Input on PLC

0V

Service port

The Service Port should not be used by non other than the Westermo Technical Support  team. Do not connect any device or cable to the Service Port.

10 6641-2211

Ethernet TX port X1 to X8

Electrical specification

Data rate

Duplex

Circuit type

Transmission range

Isolation to

Galvanic connection to

Connection

Shielded cable

Conductive housing

IEEE std 802.3. 2005 Edition

10 Mbit/s or 100 Mbit/s

Full or half

TNV-1

100 m

Other Ethernet ports, 500 VAC 

PWR, 1500 VAC

None, except for shielded contact to housing

4-pole M12 female with D-code

Not required, twisted pair is recommended

Nickel plated zinc, metal housings of X1-X8 also connected  to the housing

8 Ethernet (X1-X8)

Number of ports

Position Direction  Description

1 Out Transmit Data + 

2

3

4

In

Out

In

Receive Data +

Transmit Data –

Receive Data –

Housing Shield Chassis of product (ground)

6641-2211 11

Location of Interface ports, LED's

LED indicators 

LED

PWR

X1 to X8

Status

GREEN

RED

OFF

GREEN

GREEN 

FLASH

Description

Unit indicates no fault

Unit indicated fault

No Link

Link is up

Data is transmitted

SERVICE

X3

X1

X2

X7

X5

X6

PWR X4 X8

12 6641-2211

Mounting, DIN-rail

This unit can be mounted on 35 mm DIN-rail, which is horizontally mounted inside an  apparatus cabinet or similar. Snap on mounting, see figure.

Removal

Press down the support at the back of the unit using a screwdriver. See figure.

6641-2211 13

Wall mounting

There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M6 screws with 12 mm washer on a flat and stable  surface.

SERVICE

X3

X1

X2

X7

X5

X6

PWR X4 X8

Removal

Disconnect all cables and unscrew the unit from the wall.

Cooling

This unit uses convection cooling. Avoid obstructing the airflow around the unit. Spacing  is recommended for the use of unit in full operating temperature range and service life.

14 6641-2211

Dimensions

Measurements are stated in millimeters.

6641-2211 15

Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden

Phone +46 16 42 80 00  Fax +46 16 42 80 01 

E-mail: [email protected]

Westermo Web site: www.westermo.com

Westermo Data Communications AB 

Svalgången 1 

SE-724 81 Västerås 

Phone: +46 (0)21 548 08 00 • Fax: +46 (0)21 35 18 50  [email protected]

Westermo Data Communications Ltd 

Talisman Business Centre • Duncan Road 

Park Gate, Southampton • SO31 7GA 

Phone: +44(0)1489 580-585 • Fax.:+44(0)1489 580586 

E-Mail: [email protected]

Westermo Data Communications GmbH 

Goethestraße 67, 68753 Waghäusel 

Tel.: +49(0)7254-95400-0 • Fax.:+49(0)7254-95400-9 

E-Mail: [email protected]  

Subsidiaries

Westermo Data Communications S.A.R.L. 

9 Chemin de Chilly 91160 CHAMPLAN 

Tél : +33 1 69 10 21 00 • Fax : +33 1 69 10 21 01 

E-mail : [email protected]

Westermo Data Communications Pte Ltd 

2 Soon Wing Road #08-05 

Soon Wing Industrial Building 

Singapore 347893 

Phone +65 6743 9801 • Fax +65 6745 0670  [email protected]

Westermo Teleindustri AB have distributors in several countries, contact us for further information.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the operating temperature range for the Westermo Viper 008 switch?
The Viper 008 has a wide operating temperature range of -40 to +70°C, making it suitable for harsh industrial and rail applications.
What type of connectors does the Viper 008 have?
The Viper 008 features rugged M12 Ethernet connectors for reliable connections in demanding environments.
Does the Viper 008 have any certifications or standards compliance?
Yes, the Viper 008 complies with various standards, including EN 55022, EN 55024, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 50121-3-2, EN 50121-4, IEC 62236-4, and EN 60950-1, ensuring quality and safety.
What is the power supply range for the Viper 008?
The Viper 008 operates on a wide input power range from 24 to 110 VDC, providing flexibility in power supply options.
Is the Viper 008 suitable for use in rolling stock applications?
Yes, the Viper 008 is designed to withstand the shock and vibration encountered in rolling stock environments, making it an ideal choice for railway applications.
What is the enclosure rating for the Viper 008?
The Viper 008 has an IP65 enclosure rating when all ports are protected or connected, ensuring protection against dust and water ingress.
How does the Viper 008 handle cooling?
The Viper 008 utilizes convection cooling, eliminating the need for fans and ensuring reliable operation in environments with restricted airflow.
What mounting options are available for the Viper 008?
The Viper 008 offers flexible mounting options, including DIN rail or wall mounting, providing installation versatility.
Download PDF