advertisement
▼
Scroll to page 2
COMMERCIAL STACK DRYERS Featuring Mechanical Controls SAVE SPACE Stacked unit gives you double drying capacity in limited space. FOR YOUR CUSTOMERS • Large 7.4 Cu. Ft. Capacity • 3 Cycle Options: Heavy-Duty, Normal and Delicates • Fabric Protection Cool-Down Care • Easy-to-Follow Console Instructions • 180° Wide-Opening Side-Swing Door Allows for Convenient Access SINGLE OPERATING THERMOSTAT For simple accurate temperature control. LARGE CAPACITY METERCASE • Large Coin Box for Reduced Collections • Accepts Coin Slide, Coin-Drop and Card Reader Configurations CSP2860TQ—27" Electric Stack Dryer with Dual Metercase CSP2861TQ—27" Gas Stack Dryer with Dual Metercase Machine Accepts the Following Compatible Payment Systems (not included): — Coin Slide — Retrofit Coin-Drop — Retrofit Card Reader • 7.4 Cu. Ft. Drum Capacity • Push-to-Start Button, Rotary Controls • 3 Cycles: Heavy-Duty (High Heat), Normal (Medium Heat), and Delicates (Low Heat) • Balanced Airflow System • Large Removable, Door-Mounted Lint Screen • Front Service Accessibility • 3-Way Venting Upper Dryer (Back and Sides); 4-Way, Multi-Vent Options Lower Dryer (Back, Bottom, and Sides) *Call 1-800-NO-BELTS for warranty details. • Powdered Paint Top and Cabinet, Removable In-Door Lint Filters, T40 Torx® and Pin Security Kit Included • Optional Window Door Kit #W10791532 • Electric Model (2) Elements Rated at 5600 Watts, 240 Volt; (2) 30 Amp Circuit Breakers Required • Gas Model (2) 22K BTU Burners • Two Motors: 1/3-HP Motor with Built-In Overload Protector; Centrifugal Switch Turns Off Heating Element When Motor Stops • Electric Models Require 2 Power Cords (Sold Separately) • Gas Models: Order 2 LP Conversion Kits, Part #49572A • Mechanical Dual Metercase Money Acceptors Not Included (2 Required) • 3-Year Limited Parts Only Warranty* COMMERCIAL STACK DRYERS Featuring Mechanical Controls Whirlpool® Commercial Stack Dryers Mechanical Controls DRYER SPECIFICATIONS MODELS GENERAL INFORMATION Stainless steel look push-button console, powdered paint cabinet, improved collar assembly featuring cam lock console, taller profile and improved security metercase integral with collar, two coin box and money acceptor openings, T40 Torx® & Pin security included, removable in-door lint filters. Upper and lower dryers may use different money acceptors at the same time. 3-way venting upper dryer, 4-way lower dryer. DRUM VOLUME MOTOR ELECTRICAL REQUIREMENTS HEATER TYPE HEATER/BURNER RATING (Add 500 Watts Approx. for Motor on all Dryer Models) OPERATIONAL AMPERAGE (Does Not Include Control or Gas Valve) CSP2860TQ† CSP2861TQ†† Dual Metercase Accepts the Following Payment Systems: Coin Slide Retrofit Coin-Drop Retrofit Card Reader OPL Push-To-Start Dual Metercase Accepts the Following Payment Systems: Coin Slide Retrofit Coin-Drop Retrofit Card Reader OPL Push-To-Start 14.8 Cu. Ft. (7.4 Cu. Ft. Per Drum) Two 1/3-HP Motors with Built-In Overload Protector, 5.9 Amps Max Rating 3 or 4-Wire Nominal 240/208 Volt, 60 Hz, A.C. Standard 30 Amp Breaker/Fuse Branch Circuit per Dryer Drum (Subject to Local Codes) Electric 2 Heaters Rated at 5600 Watts per Dryer (11.2 KW Total) 14.8 Cu. Ft. (7.4 Cu. Ft. Per Drum) Two 1/3-HP Motors with Built-In Overload Protector, 5.9 Amps Max Rating Nominal 120 Volt, 60 Hz, A.C. Standard 15 Amp Breaker/Fuse Branch Circuit per Dryer Drum Motor – 4.0 Amps No Load per Motor 8 Amps Total Heater 23.33 Amps @ 240V x 2, 54.66 Total 294 Lbs. SHIPPING WEIGHT (Estimate) DIMENSIONS Width – in. (cm) Depth – in. (cm) Height – in. (cm) 27 (68.6 cm) 28.5 (72.39 cm) 76.375** (194 cm) Gas* 2 Burner Assemblies Rated at 22,000 BTU per Dryer (44,000 BTU Total) Natural Gas Motor – 4.0 Amps No Load per Motor 8 Amps Total Dimensions are for planning purposes only. For complete information, see installation instructions packed with product. FRONT VIEW 300 Lbs. 27 (68.6 cm) 28.5 (72.39 cm) 76.375** (194 cm) *Burner orifices are available for manufactured, natural, mixed and LP gas with varying BTU ratings. **Height at metercase top. †Power cords on electric models sold separately. ††LP Conversion Kit: 49572A. Energy information is available online at www.whirlpoolcommerciallaundry.com/products Exhaust Information All dryers require the equivalent of a 4-inch diameter exhaust duct. Rigid metal duct is recommended. Failure to properly exhaust the dryer will result in improper operation. # of 90° turns 27" & 29" Dryer Venting Requirements 4" Hood 2 1⁄2" Hood SIDE VIEW Maximum length of 4" diameter rigid metal duct 0 64 Ft. 58 Ft. 1 54 Ft. 48 Ft. 2 44 Ft. 38 Ft. 3 35 Ft. 29 Ft. 4 27 Ft. 21 Ft. 3-YEAR LIMITED PARTS ONLY WARRANTY For a period from the date of original purchase through the time listed above, the designated parts that fail in normal commercial use will be repaired or replaced free of charge for the part itself, with the owner paying all other costs, including labor, transportation and customs duty. Chemical damage is excluded from all warranty coverage. See complete warranty for details. BACK VIEW To Locate a Distributor Near You, Please Visit www.whirlpoolcommerciallaundry.com/distributor, or call 1-800-NO-BELTS TORX is a registered Trademark of Textron Industries, Inc. ®/™ ©2015 Whirlpool. All rights reserved. WY150058 3/15
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project