Cross Technologies 2009-8487P Up/Downconverter, 8.487 GHz 67 MHz NEW Owner's Manual

Add to My manuals
8 Pages

advertisement

Cross Technologies 2009-8487P Up/Downconverter, 8.487 GHz 67 MHz NEW Owner's Manual | Manualzz

Instruction Manual

Model 2009-8487P

Up/DownConverter

November 2013, Rev. A

C

ROSS

T

ECHNOLOGIES, INC.

2009 TEST CONVERTER

DC ALARM

IF

C

ROSS

T

ECHNOLOGIES, INC.

RF DC POWER

+DC IN

+15V, 300 ma

J3 J2 J1

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.

C ROSS T ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com

E-MAIL [email protected]

INSTRUCTION MANUAL

MODEL 2009-8487P Up/DownConverter

TABLE OF CONTENTS PAGE

Warranty

1.0 General

1.1 Equipment Description

1.2 Technical Characteristics

2.0 Installation

2.1 Mechanical

2.2 Front Panel Indicators

2.3 Rear Panel Inputs and Outputs

2.4 Accessing the PC Card

2.5 Installation/Operation

3.0 Environmental Use Information

4

5

5

5

2

3

3

6

7

6

6

WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.

All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein.

2009-8487P Manual, Rev. A

C ROSS T ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com

E-MAIL [email protected]

Page 2 11/11/13

Model 2009-8487P Up/DownConverter

1.0 General

1.1 Equipment Description

The 2009-8487P Up/DownConverter, for loop-back applications, converts a 8.487 GHz signal to or from 67

MHz with a low side local oscillator (LO) (non-inverted spectrum). Featuring low phase noise and high stability, this unit is used to down convert “clean” (having only this frequency) 8.487 GHz signal to 67 MHz or up convert 67 MHz to 8.487 GHz for test purposes. A synthesized local oscillator (LO) of 8.420 GHz converts the 8.487 GHz signal to 67 MHz when used as a Downconverter and the 67 MHz signal to 8.487 GHz when used as a Upconverter with a nominal gain of -15dB. Connectors are SMA (female) for the 67 MHz IF and the

RF ports. Front panel LEDs light when DC power is applied (green) and when a PLL alarm occurs (red). The unit is powered by a 120 ±10% VAC wall mount power supply (suffix P) and other power supply options are available (option P4 or option -C). The 2009 can be mounted on an 1.75” X 19” rack mount panel (option R).

C

ROSS

T

ECHNOLOGIES, INC.

2009 TEST CONVERTER

DC ALARM

IF

J1

FIGURE 1.1 Front and Rear Panels

C

ROSS

T

ECHNOLOGIES, INC.

RF DC POWER

+DC IN

+15V, 300 ma

J3 J2

8.487

GHz atten

67

LP

FILTER

MHz

8.420 GHz PLL

2009-8487P Block Diagram

FIGURE 1.2 Block Diagram

2009-8487P Manual, Rev. A Page 3 11/11/13

1.2 Technical Characteristics

TABLE 1.1 Model 2009-8487P Equipment Specifications*

EQUIPMENT SPECIFICATIONS*

RF Characteristics

Impedance / Return Loss

Frequency

50 Ω / 12 db

8487 MHz ± 20 MHz

Level, In, Downconverter -30 to -5 dBm

Level, Out, Upconverter

Input 1 dB compression

IF Characteristics

-30 to -20 dBm

+5 dBm

Impedance / Return Loss

Frequency

Level, In, Upconverter

50 Ω / 12 db

67 MHz ± 20 MHz

-15 to -5 dBm

Level, Out, Downconverter -45 to -20 dBm

Channel Characteristics

Gain at band center

Spurious Response

Spectrum Sense

Frequency Response

-15 dB ±2 dB

<-40 dBC, ± 20 MHz of the center frequency

Non-inverting

± 0.5 dB, ± 20 MHz of the center frequency

Synthesizer Characteristics

Frequency Accuracy

Phase Noise @ Freq

dBC/Hz

Indicators

DC Power

Alarm

± 2.5 ppm maximum

10Hz 1kHz

-70

Green LED

Red LED

-75

10kHz

-80

100kHz

-95

Other

RF Connector

IF Connector

Size, Bench Top

Size, Rack Mount (-R)

Power

Options

-C

-P4

-R

SMA (female), 50

SMA (female), 50

Ω

Ω

4.7” wide X 1.75” high X 6.5” deep

1MHz

-110

19 inch standard chassis 1.75” high X 7.0” deep (optional)

120 ±10% VAC Wall Power Supply providing +15 to +18 VDC

No Power Supply. Use with Cross 2000-01 Power Supply

100-240 ± 10% VAC Wall Power Supply

1RU Rack Mounting

*+10˚C to +40˚C; 2 km maximum elevation; 90% maximum humidity; Specifications subject to change without notice

2009-8487P Manual, Rev. A Page 4 11/11/13

2.0 Installation

2.1 Mechanical

The 2009-8487P is packaged in an aluminum extrusion. The -R option is mounted on a 1 3/4” X 19” panel that can be mounted to a rack using the 4 holes at the ends (See Figure 2.1).

2.1.1 Cleaning Instructions

Wipe the exterior with a dry, soft cloth. Use no detergent or cleaning chemicals.

REAR SCREWS (4EA)

REAR PANEL

EXTRUSION

FRONT PANEL

C

ROSS

T

ECHNOLOGIES, INC.

2009 TEST DOWNCONVERTER

DC ALARM

RACK MOUNT PANEL (FOR -R MODELS ONLY)

FRONT SCREWS (4EA)

FIGURE 2.1 Model 2009-8487P Assembly (-R option shown)

2.2 Indicators

Figure 2.2 shows front panel indicators.

C

ROSS

T

ECHNOLOGIES, INC.

2009 TEST CONVERTER

DC ALARM

DS1 - DC POWER LED

Lights green when DC power is present.

DS2 - ALARM LED

Lights red when PLL comes out of lock.

FIGURE 2.2 Model 2009-8487P Front Panel Indicators

2009-8487P Manual, Rev. A Page 5 11/11/13

2.3 Input / Output Signals

Figure 2.3 shows the input and output signals to the 2009-8487P.

J1 - IF IN/OUT

The 67 MHz input/output.

This must be a “clean” input with no image or other frequency present. The maximum input level is -5 dBm. This is a 50 Ω ,

SMA, female connector.

GND +15 to +18

J3 - DC POWER

+15VDC Input, 400 mA (-P models ONLY.)

IF

C

ROSS

T

ECHNOLOGIES, INC.

RF DC POWER

+DC IN

+15V, 300 ma

J2 - RF IN/OUT

The 8487 MHz input/output.

This must be a “clean” input with no image or other frequency present. The maximum input level is -5 dBm.

This is a 50 Ω , SMA, female connector.

J1 J3 J2

FIGURE 2.3 Model 2009-8487P Rear Panel Inputs and Outputs

2.4 Accessing the PC Card

There are NO USER JUMPERS or other on-card controls. ALTHOUGH IT IS NOT RECOMMENDED AND

MAY VOID THE WARRANTY the following shows how to remove the printed circuit board (PCB) from the extrusion:

1. Always remove power when installing or removing the PCB from the extrusion.

2. Remove four (4) rear panel screws (see Figure 2.1).

3. Gently pull the rear panel and PCB assembly completely out of the extrusion.

4. To install the PCB, gently push the rear panel and PCB assembly completely into the extrusion

(make sure the shield goes in the lower channel and the PCB in the next channel above that) and that the front panel indicators line up with the front panel holes.

5. Install four (4) rear panel screws.

2.5 Installation / Operation

2.5.1 Installing and Operating the 2009-8487P

1. For Option -P models, connect one end of the Wall Power Supply to the 2009-8487P

DC Power In, J3, and the other end to 115 VAC, 60 Hz (Figure 2.3).

2. Connect a -5 dBm, maximum, signal to IF IN, J1 or RF IN, J2 (Figure 2.3).

3. Connect the IF OUT, J2, to the receiver under test (Figure 2.3).

4. Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).

2009-8487P Manual, Rev. A Page 6 11/11/13

3.0 Environmental Use Information

A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack.

B. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution.

C. Elevated operating ambient temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature.

Therefore, consideration should be given to Tmra.

D. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required.

E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring.

Appropriate consideration of equipment name plate rating should be used, when addressing this concern.

F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch

(use of power strips).

G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed.

If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems.

2009-8487P Manual, Rev. A Page 7 11/11/13

2009-8487P Manual, Rev. A

C ROSS T ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com

E-MAIL [email protected]

Printed in USA

Page 8 11/11/13