Cross Technologies 1200-03 IF Processor (Switch/Splitter), 70 MHz Owner's Manual

Add to My manuals

advertisement

Cross Technologies 1200-03 IF Processor (Switch/Splitter), 70 MHz Owner's Manual | Manualzz
Model 1200-03
Instruction Manual
IF Processor
January 2009 Rev B
RX
IF MON
J1
DIG1
FDM
DIG2
ON
ON
DIG1
SW1
FDM
SW2
ON
LOCAL
DIG2 REMOTE
SW3
SW4
MODEL 1200
TX
IF MON
IF PROCESSOR
GAIN
R1
LOCAL OVERRIDE
R2
R3
T1
CROSS TECHNOLOGIES, INC.
T2
T3
J2
DC
FRONT
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL [email protected]
INSTRUCTION MANUAL
MODEL 1200-03 IF PROCESSOR
TABLE OF CONTENTS
Warranty
1.0 General
1.1 Equipment Description
1.2 Technical Characteristics
1.3 Use Information
2.0 Installation
2.1 Mechanical
2.2 Rear I/O’s, Control
2.3 Front Panel I/O’s, Indicators
2.4 Operation
PAGE
2
3
3
4
6
7
7
8
8
9
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and
workmanship for a period of one year after shipment to customer. Cross Technologies,
Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies,
Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies,
Inc. shall not be liable for any special, indirect, or consequential damages. This
warranty does not cover parts or equipment which have been subject to misuse,
negligence, or accident by the customer during use. All shipping costs for warranty
repairs will be prepaid by the customer. There are not other warranties, express or
implied, except as stated herein.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL [email protected]
1200-03 Manual, Rev. B
Page 2
01/08/09
MODEL 1200-03 IF PROCESSOR
1.0 General
1.1 Equipment Description - The 1200-03 IF Processor consists of a transmit and receive side. The receive
side consists of one receive IF signal going through an Automatic Gain Control (AGC) amplifier and then
split into three signals, DIG1RX, FDMRX, DIG2RX each having variable attenuators to adjust their levels
over a 30dB output range via front panel multi-turn potentiometers. The AGC amplifier provides Automatic
Gain Control for a 50 to 90 MHz IF signal for a -80 to 0 dBm input level to a -35dBm ±10dB output. A front
panel monitor port provides a monitor signal out of the AGC amplifier.
The transmit side consists of three transmit IF signals combined into one. Transmit DIGTX, FDMTX, and
DIG2TX signals each pass through individual attenuators controlled via front panel multi-turn
potentiometers and a switch that is controlled remotely through a DB9 connector or locally with three 2PDT
switches located on the front panel.
A 2PDT switch on the front panel selects either REMOTE or LOCAL operation. On the DB9 connector a
closure to +V will turn the corresponding transmit channels on. A local override feature is included such that
when the REMOTE/LOCAL 2PDT switch on the front panel is left in the LOCAL position, the override pin
on the DB9 can be set to +V to override the LOCAL control and allow for REMOTE control. DIG1 and
DIG2 on both transmit and receive sides are 75 in/out while FDM on both transmit and receive sides are
50 in/out. When power is removed from the 1200-03, the FDM TX and FDM RX signals pass through to
the output.
The IF in and out connectors are BNC female. All circuitry is on a single PCB housed in a 1RU X 14”
deep chassis. An internal switching power supply powers the unit with a 100-240 ±10% VAC, 47-63 Hz
input.
RX
IF MON
ON
ON
ON
MODEL 1200
TX
IF MON
LOCAL
IF PROCESSOR
GAIN
J1
DIG1
FDM
DIG2
DIG1
SW1
FDM
SW2
DIG2
SW3
REMOTE
SW4
R1
LOCAL
OVERRIDE
R2
R3
CROSS TECHNOLOGIES, INC.
T1
T2
J2
T3
DC
FRONT
AC IN
GND
DIG1
TX IN
FDM
TX IN
DIG2
TX IN
TX
IF OUT
CONTROL
DIG1
RX OUT
FDM
RX OUT
DIG2
RX OUT
RX
IF IN
J101
J102
J103
J104
J105
J106
J107
J108
J109
REAR
FIGURE 1.1 Model 1200-03 Front and Rear Panels
1200-03 Manual, Rev. B
Page 3
01/08/09
1.2 Technical Characteristics
TABLE 1.1 1200-03 IF Processor Specifications*
RX Input Characteristics
Impedance/Return Loss
50 /18 dB
Frequency
50 to 90 MHz
Input Level Range/1dB
0 to -80 dBm / +5 dBm
RX Output Characteristics
Impedance/Return Loss
FDM RX 50 / 18dB; DIG1, DIG2 RX 75 /18 dB (with 5dB
attenuation on each channel)
Output Level, nom/max
-35 ± 10 dBm / -10 dBm
Output Level Adjust
-35 to -65 dB ± 10 dB at -35 dBm nominal
RX IF Mon Output Level
-35 ± 10 dBm
RX Channel Characteristics
Gain, AGC
-35 to +45 dB range
Frequency Response
±1.0 dB
TX Input Characteristics
Impedance/Return Loss
FDM TX 50 / 18dB; DIG1, DIG2 TX 75 /18 dB (with 5dB
attenuation on each channel)
Frequency
50 to 90 MHz
Input Level Range
-20 to +5 dBm
Input Level Adjust
0 to -30 dBm with 0 dBm in
TX Output Characteristics
Impedance/Return Loss
50 /18 dB
Output Level Range/1dB
-50 to +5 dBm / +10 dBm
TX Channel Characteristics
Gain Adjustment
0 to -30 dB, each channel individually adjustable
Frequency Response
±1.0 dB
Group Delay
5 ns, max
TX Switch Characteristics
Isolation, Switch off
60 dB
Isolation, Port to Port
50 dB, all “ON” and 5dB attenuation on each channel
Switch Time
10 ms
Controls, Indicators
Front Panel Controls
SW1, SW2, SW3
DIG1 TX, FDM TX, DIG2 TX switches (2PDT)
SW4
LOCAL/REMOTE switch (2PDT)
Front Panel Indicators
DIG1, FDM, DIG2
Green LED indicates DIG1 TX, FDM TX, DIG2 TX are “ON”
OVERRIDE
Yellow LED indicates override of LOCAL control
LOCAL
Red LED indicates SW4 set to LOCAL control
DC
Green LED indicates power is supplied to the unit
Front Panel Monitors
J1, J2
RX AGC Monitor, TX IF Out Monitor
Other
IF Connectors
BNC, female
Connector, Control
DB9, female
Size
19 inch standard chassis 1.75”high X 14.0” deep
Power
100-240 ±10% VAC, 47 - 63 Hz, 30 watts max.
*+10 to +40 degrees C; Specifications subject to change without notice
1200-03 Manual, Rev. B
Page 4
01/08/09
1200-03 Manual, Rev. B
Page 5
01/08/09
1.3 Use Information
A. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack may be greater than room ambient temperature.
Therefore, consideration should be given to Tmra.
B. Reduced air flow - Installation of the equipment in a rack should be such that the amount of
air flow required for safe operation of the equipment is not compromised. Additional space between
unit may be required.
C. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition
does not exist due to uneven weight distribution.
D. Circuit Overloading - Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of circuits could have on over current protection and
supply wiring. Appropriate consideration of equipment name plate rating should be used, when
addressing this concern.
E. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connection to the
Branch (use of power strips).
F. Top Cover - There are no servicable parts inside the product so, the Top Cover should not be removed.
If the Top Cover is removed the ground strap and associated screw MUST BE RE-INSTALLED
prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS
emission problems.
1200-03 Manual, Rev. B
Page 6
01/08/09
2.0 Installation
2.1 Mechanical - The 1200-03 consists of one PCB assembly and one power supply housed in a 1 RU (1 3/4
inch high) by 14 inch deep chassis. An AC power supply provides +15VDC and -15VDC to the PCB. The
1200-03 can be secured to a rack using the 4 holes on the front panel. Figure 2.1 shows how the 1200-03 is
assembled.
FRONT
1
POWER
SUPPLY
J3
PIN
1
2
3
DESC
GND
-15V
+15V
REAR
FIGURE 2.1 1200-03 Mechanical Assembly
1200-03 Manual, Rev. B
Page 7
01/08/09
2.2
Rear Panel Input/Output Signals and Controls - Figure 2.2 and Table 2.1 show the input, output.
and control connectors on the rear panel.
AC INPUT
AC input for power supply. 100-240
±10% VAC, 47-63 Hz, 30W max.
J106 - DIG1 RX OUT
Output, BNC female, 50.
AC
GND
J107 - FDM RX OUT
Output, BNC female, 50.
J108 - DIG2 RX OUT
Output, BNC female, 50.
DIG1
TX IN
FDM
TX IN
DIG2
TX IN
TX
IF OUT
CONTROL
J10
J102
J103
J104
J105
DIG1
RX OUT
J10
FDM
RX OUT
DIG2
RX OUT
RX
IF IN
J107
J108
J109
6
1
J101 - DIG1 TX IN
Input, BNC female, 50.
J109 - RX IF IN
Input, BNC female, 50.
J102 - FDM TX IN
Input, BNC female, 50.
J103 - DIG2 TX IN
Input, BNC female, 50.
J104 - TX IF OUT
Output, BNC female, 50.
J105 - SWITCH CONTROL
DB9, female. Allows for REMOTE control of the
1200-03 TX switches, and contains AGC and
LOCAL indicator signals. See Tables 2.1 and 2.2.
FIGURE 2.2 1200-03 Rear Panel I/Os and Control
5 4 3 2 1
9 8 7 6
TABLE
2.1
PIN
J105
(DB9)
Control/Indicator
Control/
/ Indicator
Signals
CONTROLS
1
SELECT DIG1 TX IN
External Closure In
GND/Open OFF; +15 VDC(+V) ON
2
SELECT FDM TX IN
External Closure In
GND/Open OFF; +15 VDC(+V) ON
3
SELECT DIG2 TX IN
External Closure In
GND/Open OFF; +15 VDC(+V) ON
4
LOCAL Indicator OUT
Indicator Output
GND LOCAL Control; Open REMOTE Control
GND
Ground Reference
59
2.3
-
6
OVERRIDE IN
Local Override Input
+15 VDC (+V) overrides LOCAL control and allows for REMOTE control
7
AGC OUT
AGC Voltage
Indicates current AGC gain (see Table 2.2)
8
+V
DC Voltage Reference +15 VDC
Front Panel Controls and Indicators - The following are the front panel outputs, controls and
indicators.
DS1 - DIG1 LED
Lights green when
DIG1 TX is on.
DS2 - FDM LED
Lights green when
FDM TX is on.
DS3 - DIG2 LED
Lights green when
DIG2 TX is on.
DS4 - LOCAL LED
Lights red when in
LOCAL operation.
DS5 - OVERRIDE LED
Lights yellow when REMOTE
control is overriding LOCAL
control.
RX
IF MON
R1, R2, R3, T1, T2, T3 - ADJUSTABLE ATTEN
Potentiometers that control the attenuation of RX
DIG1 (R1), RX FDM (R2), RX DIG2 (R3), TX DIG1
(T1), TX FDM (T2), and TX DIG2 (T3) channels.
Adjustable from 0 to 30 dB attenuation. Clockwise
rotation decreases attenuation.
MODEL 1200
TX
IF MON
ON
ON
ON
IF PROCESSOR
LOCAL
GAIN
REMOTE
J1
J1 - RX IF MON
RX monitor output
after AGC, BNC
female.
DIG1
FDM
DIG2
SW1 - DIG1 TX SW
Turns on (up) DIG1
TX input when in
LOCAL operation.
DIG1
FDM
DIG2
SW1
SW2
SW3
SW2 - FDM TX SW
Turns on (up) FDM
TX input when in
LOCAL operation.
SW4
R1
R2
R3
T1
T2
T3
LOCAL OVERRIDE J2
SW3 - DIG2 TX SW
Turns on (up) DIG2
TX input when in
LOCAL operation.
DC
SW4 - LOCAL/REMOTE SW J2 - TX IF MON
DS6 - POWER LED
Switches between LOCAL
TX monitor output of the Lights green when
and REMOTE operation.
switched (combined) TX DC power is applied.
output, BNC female.
FIGURE 2.3 1200-03 Front Panel Controls and Indicators
1200-03 Manual, Rev. B
Page 8
01/08/09
2.4
Operation
2.4.1
Installing and Operating the 1200-03
1.) Install the 1200-03 in the equipment rack.
2.) Connect to signals on the CONTROL connector, J105, as desired (Figure 2.2).
3.) Connect 100-240 ±10% VAC, 47 - 63 Hz to AC IN on the back panel (Figure 2.2).
4.) Be sure the DC (power) LED, DS6, is on (Figure 2.3).
5.) Set SW4 for REMOTE or LOCAL operation (Figure 2.3).
6.) Choose the desired TX path(s) either remotely (J105, Figure 2.2) or locally using the front-panel
switches (SW1 - SW3, Figure 2.3) and check for proper signal(s) at TX IF MON (J2, Figure 2.3) or
TX IF OUT (J104, Figure 2.2) and that the appropriate LED(s) (DS1 - DS3, Figure 2.3) is lit.
7.) Adjust attenuator pots (R1, R2, R3, T1, T2, T3) as needed. Clockwise rotation provides
increased output level (full clockwise = 0 dB atten, full counter-clockwise = 30 dB atten).
8.) AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot
in the drawer below the AC input as shown in Figure 2.4. There is a spare fuse in the near slot. If a
fuse continues to open, the power supply is most likely defective.
FUSE DRAWER
SPARE FUSE DRAWER
AC Fuse - 2 amp slow blow (Type T 2A GDC),
5 mm X 20 mm
INPUT
~
100-240± 10%VAC
47-63 Hz
2A MAX
FUSE
TYPE T 2A GDC
250 VOLT
FOR 100 - 240 V~
FIGURE 2.4 Fuse Location and Spare Fuse
1200-03 Manual, Rev. B
Page 9
01/08/09
2.4.2 AGC voltage relating to Gain - The 1200-03 IF Processor operates over a 0 to -80 dBm input range
on the RX IF side. The Automatic Gain Control (AGC) provides a constant -35 dBm ± 10 dBm output RX IF
level over the entire input range. Pin 7 of the DB9 control connector, J105, can be monitored to determine
the approximate input level (and corresponding gain) in AGC as Table 2.2 shows.
TABLE 2.2 - Approximate AGC Voltage
Vo
oltage vs Gain and Input Level
Le
evel
AGC Voltage (pin 7, J105)
AGC Gain
Input Level
+0.3 VDC
-35 dB
0 dBm
1200-03 Manual, Rev. B
+0.1 VDC
-25 dB
-10 dBm
-0.7 VDC
-15 dB
-20 dBm
-1.4 VDC
-5 dB
-30 dBm
-1.8 VDC
+5 dB
-40 dBm
-2.1 VDC
+15 dB
-50 dBm
-2.3 VDC
+25 dB
-60 dBm
-2.5 VDC
+35 dB
-70 dBm
-2.7 VDC
+45 dB
-80 dBm
Page 10
01/08/09
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL [email protected]
1200-03 Manual, Rev. B
Page 11
01/08/09