Cross Technologies 1200-03 IF Processor (Switch/Splitter), 70 MHz Owner's Manual
Add to My manualsadvertisement
◉
Touch to zoom
Model 1200-03 Instruction Manual IF Processor January 2009 Rev B RX IF MON J1 DIG1 FDM DIG2 ON ON DIG1 SW1 FDM SW2 ON LOCAL DIG2 REMOTE SW3 SW4 MODEL 1200 TX IF MON IF PROCESSOR GAIN R1 LOCAL OVERRIDE R2 R3 T1 CROSS TECHNOLOGIES, INC. T2 T3 J2 DC FRONT Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] INSTRUCTION MANUAL MODEL 1200-03 IF PROCESSOR TABLE OF CONTENTS Warranty 1.0 General 1.1 Equipment Description 1.2 Technical Characteristics 1.3 Use Information 2.0 Installation 2.1 Mechanical 2.2 Rear I/O’s, Control 2.3 Front Panel I/O’s, Indicators 2.4 Operation PAGE 2 3 3 4 6 7 7 8 8 9 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] 1200-03 Manual, Rev. B Page 2 01/08/09 MODEL 1200-03 IF PROCESSOR 1.0 General 1.1 Equipment Description - The 1200-03 IF Processor consists of a transmit and receive side. The receive side consists of one receive IF signal going through an Automatic Gain Control (AGC) amplifier and then split into three signals, DIG1RX, FDMRX, DIG2RX each having variable attenuators to adjust their levels over a 30dB output range via front panel multi-turn potentiometers. The AGC amplifier provides Automatic Gain Control for a 50 to 90 MHz IF signal for a -80 to 0 dBm input level to a -35dBm ±10dB output. A front panel monitor port provides a monitor signal out of the AGC amplifier. The transmit side consists of three transmit IF signals combined into one. Transmit DIGTX, FDMTX, and DIG2TX signals each pass through individual attenuators controlled via front panel multi-turn potentiometers and a switch that is controlled remotely through a DB9 connector or locally with three 2PDT switches located on the front panel. A 2PDT switch on the front panel selects either REMOTE or LOCAL operation. On the DB9 connector a closure to +V will turn the corresponding transmit channels on. A local override feature is included such that when the REMOTE/LOCAL 2PDT switch on the front panel is left in the LOCAL position, the override pin on the DB9 can be set to +V to override the LOCAL control and allow for REMOTE control. DIG1 and DIG2 on both transmit and receive sides are 75 in/out while FDM on both transmit and receive sides are 50 in/out. When power is removed from the 1200-03, the FDM TX and FDM RX signals pass through to the output. The IF in and out connectors are BNC female. All circuitry is on a single PCB housed in a 1RU X 14” deep chassis. An internal switching power supply powers the unit with a 100-240 ±10% VAC, 47-63 Hz input. RX IF MON ON ON ON MODEL 1200 TX IF MON LOCAL IF PROCESSOR GAIN J1 DIG1 FDM DIG2 DIG1 SW1 FDM SW2 DIG2 SW3 REMOTE SW4 R1 LOCAL OVERRIDE R2 R3 CROSS TECHNOLOGIES, INC. T1 T2 J2 T3 DC FRONT AC IN GND DIG1 TX IN FDM TX IN DIG2 TX IN TX IF OUT CONTROL DIG1 RX OUT FDM RX OUT DIG2 RX OUT RX IF IN J101 J102 J103 J104 J105 J106 J107 J108 J109 REAR FIGURE 1.1 Model 1200-03 Front and Rear Panels 1200-03 Manual, Rev. B Page 3 01/08/09 1.2 Technical Characteristics TABLE 1.1 1200-03 IF Processor Specifications* RX Input Characteristics Impedance/Return Loss 50 /18 dB Frequency 50 to 90 MHz Input Level Range/1dB 0 to -80 dBm / +5 dBm RX Output Characteristics Impedance/Return Loss FDM RX 50 / 18dB; DIG1, DIG2 RX 75 /18 dB (with 5dB attenuation on each channel) Output Level, nom/max -35 ± 10 dBm / -10 dBm Output Level Adjust -35 to -65 dB ± 10 dB at -35 dBm nominal RX IF Mon Output Level -35 ± 10 dBm RX Channel Characteristics Gain, AGC -35 to +45 dB range Frequency Response ±1.0 dB TX Input Characteristics Impedance/Return Loss FDM TX 50 / 18dB; DIG1, DIG2 TX 75 /18 dB (with 5dB attenuation on each channel) Frequency 50 to 90 MHz Input Level Range -20 to +5 dBm Input Level Adjust 0 to -30 dBm with 0 dBm in TX Output Characteristics Impedance/Return Loss 50 /18 dB Output Level Range/1dB -50 to +5 dBm / +10 dBm TX Channel Characteristics Gain Adjustment 0 to -30 dB, each channel individually adjustable Frequency Response ±1.0 dB Group Delay 5 ns, max TX Switch Characteristics Isolation, Switch off 60 dB Isolation, Port to Port 50 dB, all “ON” and 5dB attenuation on each channel Switch Time 10 ms Controls, Indicators Front Panel Controls SW1, SW2, SW3 DIG1 TX, FDM TX, DIG2 TX switches (2PDT) SW4 LOCAL/REMOTE switch (2PDT) Front Panel Indicators DIG1, FDM, DIG2 Green LED indicates DIG1 TX, FDM TX, DIG2 TX are “ON” OVERRIDE Yellow LED indicates override of LOCAL control LOCAL Red LED indicates SW4 set to LOCAL control DC Green LED indicates power is supplied to the unit Front Panel Monitors J1, J2 RX AGC Monitor, TX IF Out Monitor Other IF Connectors BNC, female Connector, Control DB9, female Size 19 inch standard chassis 1.75”high X 14.0” deep Power 100-240 ±10% VAC, 47 - 63 Hz, 30 watts max. *+10 to +40 degrees C; Specifications subject to change without notice 1200-03 Manual, Rev. B Page 4 01/08/09 1200-03 Manual, Rev. B Page 5 01/08/09 1.3 Use Information A. Elevated operating ambient temperature - if installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. B. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between unit may be required. C. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. D. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used, when addressing this concern. E. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). F. Top Cover - There are no servicable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE RE-INSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1200-03 Manual, Rev. B Page 6 01/08/09 2.0 Installation 2.1 Mechanical - The 1200-03 consists of one PCB assembly and one power supply housed in a 1 RU (1 3/4 inch high) by 14 inch deep chassis. An AC power supply provides +15VDC and -15VDC to the PCB. The 1200-03 can be secured to a rack using the 4 holes on the front panel. Figure 2.1 shows how the 1200-03 is assembled. FRONT 1 POWER SUPPLY J3 PIN 1 2 3 DESC GND -15V +15V REAR FIGURE 2.1 1200-03 Mechanical Assembly 1200-03 Manual, Rev. B Page 7 01/08/09 2.2 Rear Panel Input/Output Signals and Controls - Figure 2.2 and Table 2.1 show the input, output. and control connectors on the rear panel. AC INPUT AC input for power supply. 100-240 ±10% VAC, 47-63 Hz, 30W max. J106 - DIG1 RX OUT Output, BNC female, 50. AC GND J107 - FDM RX OUT Output, BNC female, 50. J108 - DIG2 RX OUT Output, BNC female, 50. DIG1 TX IN FDM TX IN DIG2 TX IN TX IF OUT CONTROL J10 J102 J103 J104 J105 DIG1 RX OUT J10 FDM RX OUT DIG2 RX OUT RX IF IN J107 J108 J109 6 1 J101 - DIG1 TX IN Input, BNC female, 50. J109 - RX IF IN Input, BNC female, 50. J102 - FDM TX IN Input, BNC female, 50. J103 - DIG2 TX IN Input, BNC female, 50. J104 - TX IF OUT Output, BNC female, 50. J105 - SWITCH CONTROL DB9, female. Allows for REMOTE control of the 1200-03 TX switches, and contains AGC and LOCAL indicator signals. See Tables 2.1 and 2.2. FIGURE 2.2 1200-03 Rear Panel I/Os and Control 5 4 3 2 1 9 8 7 6 TABLE 2.1 PIN J105 (DB9) Control/Indicator Control/ / Indicator Signals CONTROLS 1 SELECT DIG1 TX IN External Closure In GND/Open OFF; +15 VDC(+V) ON 2 SELECT FDM TX IN External Closure In GND/Open OFF; +15 VDC(+V) ON 3 SELECT DIG2 TX IN External Closure In GND/Open OFF; +15 VDC(+V) ON 4 LOCAL Indicator OUT Indicator Output GND LOCAL Control; Open REMOTE Control GND Ground Reference 59 2.3 - 6 OVERRIDE IN Local Override Input +15 VDC (+V) overrides LOCAL control and allows for REMOTE control 7 AGC OUT AGC Voltage Indicates current AGC gain (see Table 2.2) 8 +V DC Voltage Reference +15 VDC Front Panel Controls and Indicators - The following are the front panel outputs, controls and indicators. DS1 - DIG1 LED Lights green when DIG1 TX is on. DS2 - FDM LED Lights green when FDM TX is on. DS3 - DIG2 LED Lights green when DIG2 TX is on. DS4 - LOCAL LED Lights red when in LOCAL operation. DS5 - OVERRIDE LED Lights yellow when REMOTE control is overriding LOCAL control. RX IF MON R1, R2, R3, T1, T2, T3 - ADJUSTABLE ATTEN Potentiometers that control the attenuation of RX DIG1 (R1), RX FDM (R2), RX DIG2 (R3), TX DIG1 (T1), TX FDM (T2), and TX DIG2 (T3) channels. Adjustable from 0 to 30 dB attenuation. Clockwise rotation decreases attenuation. MODEL 1200 TX IF MON ON ON ON IF PROCESSOR LOCAL GAIN REMOTE J1 J1 - RX IF MON RX monitor output after AGC, BNC female. DIG1 FDM DIG2 SW1 - DIG1 TX SW Turns on (up) DIG1 TX input when in LOCAL operation. DIG1 FDM DIG2 SW1 SW2 SW3 SW2 - FDM TX SW Turns on (up) FDM TX input when in LOCAL operation. SW4 R1 R2 R3 T1 T2 T3 LOCAL OVERRIDE J2 SW3 - DIG2 TX SW Turns on (up) DIG2 TX input when in LOCAL operation. DC SW4 - LOCAL/REMOTE SW J2 - TX IF MON DS6 - POWER LED Switches between LOCAL TX monitor output of the Lights green when and REMOTE operation. switched (combined) TX DC power is applied. output, BNC female. FIGURE 2.3 1200-03 Front Panel Controls and Indicators 1200-03 Manual, Rev. B Page 8 01/08/09 2.4 Operation 2.4.1 Installing and Operating the 1200-03 1.) Install the 1200-03 in the equipment rack. 2.) Connect to signals on the CONTROL connector, J105, as desired (Figure 2.2). 3.) Connect 100-240 ±10% VAC, 47 - 63 Hz to AC IN on the back panel (Figure 2.2). 4.) Be sure the DC (power) LED, DS6, is on (Figure 2.3). 5.) Set SW4 for REMOTE or LOCAL operation (Figure 2.3). 6.) Choose the desired TX path(s) either remotely (J105, Figure 2.2) or locally using the front-panel switches (SW1 - SW3, Figure 2.3) and check for proper signal(s) at TX IF MON (J2, Figure 2.3) or TX IF OUT (J104, Figure 2.2) and that the appropriate LED(s) (DS1 - DS3, Figure 2.3) is lit. 7.) Adjust attenuator pots (R1, R2, R3, T1, T2, T3) as needed. Clockwise rotation provides increased output level (full clockwise = 0 dB atten, full counter-clockwise = 30 dB atten). 8.) AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.4. There is a spare fuse in the near slot. If a fuse continues to open, the power supply is most likely defective. FUSE DRAWER SPARE FUSE DRAWER AC Fuse - 2 amp slow blow (Type T 2A GDC), 5 mm X 20 mm INPUT ~ 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 - 240 V~ FIGURE 2.4 Fuse Location and Spare Fuse 1200-03 Manual, Rev. B Page 9 01/08/09 2.4.2 AGC voltage relating to Gain - The 1200-03 IF Processor operates over a 0 to -80 dBm input range on the RX IF side. The Automatic Gain Control (AGC) provides a constant -35 dBm ± 10 dBm output RX IF level over the entire input range. Pin 7 of the DB9 control connector, J105, can be monitored to determine the approximate input level (and corresponding gain) in AGC as Table 2.2 shows. TABLE 2.2 - Approximate AGC Voltage Vo oltage vs Gain and Input Level Le evel AGC Voltage (pin 7, J105) AGC Gain Input Level +0.3 VDC -35 dB 0 dBm 1200-03 Manual, Rev. B +0.1 VDC -25 dB -10 dBm -0.7 VDC -15 dB -20 dBm -1.4 VDC -5 dB -30 dBm -1.8 VDC +5 dB -40 dBm -2.1 VDC +15 dB -50 dBm -2.3 VDC +25 dB -60 dBm -2.5 VDC +35 dB -70 dBm -2.7 VDC +45 dB -80 dBm Page 10 01/08/09 CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL [email protected] 1200-03 Manual, Rev. B Page 11 01/08/09
advertisement
Related manuals
advertisement