Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, hertz, wattage, amps, and phase is attached to the product.

To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction.

GENERAL INFORMATION

EXCESSIVE WEIGHT HAZARD

Use two or more people to move and install refrigerator.

Failure to follow this instruction can result in back or other injury.

Most of the refrigerator’s weight is at the top.

Extra care is needed when moving the refrigerator to prevent tipping. Keep cardboard shipping piece or plywood under refrigerator until it is installed in the operating position.

It is your responsibility to :

-comply with installation specifications and dimensions

-properly install refrigerator

-make sure that you have these materials which are necessary for proper installation:

1/4” (6 mm) copper tubing with shutoff valve

1/4” (6mm) compression fitting

-assure that floor will support refrigerator (more than 600 lbs. [272 kg.]), door panels and contents

-provide a properly grounded electrical outlet

-assure that location will permit appliance doors to open 90 o minimum

CUTOUT DIMENSIONS

Diagram A

A

B

I

C

D

E

F

G

H

J

P

Q

R

M

N

O

K

L

Description

Width of lag bolt location

Distance from right side of cutout to left lag bolt location

Width of receptacle location

Distance from right side of cutout to right lag bolt location

Height to top of receptacle location and bottom of 2” x 4” (5.1 cm x 10.2 cm) mounting board (including cover plate)

Height to bottom of receptacle location (including cover plate)

Height of cutout (min.)

Depth of water line location on side wall

Position of water line location on back wall

Width of water line location on back wall

Height of water line location on side wall

Height of water line location on back wall

Depth of cutout (min.)

Do not place water line in this location

Width of water line location on floor

Water valve location

Depth of water line location on floor

Width of cutout (min.)

Dimension

1” (2.54 cm)

32 9/16” (82.7 cm)

27 1/2” (69.9 cm)

3 3/8” 8.6 cm)

80 1/2” (204.5 cm)

75 1/8” (190.8 cm)

84” (213.4 cm)

1” (2.54 cm)

7 5/8” (19.4 cm)

6 3/4” (17.1 cm)

5/8’ (1.6 cm)

3” (7.6 cm)

24” (61.0 cm)

3 5/8” (9.2 cm)

10 3/4” (27.3 cm)

See diagram

10 1/2” (26.7 cm)

35 1/2” (90.2 cm)

Verify cutout depth is a minimum of 24” (61.0 cm) measuring from the rear of the cutout to the front. Minimum refrigerator height is 83 1/4” (211.5 cm) with refrigerator adjusted to its lowest position. Maximum refrigerator height is

84 1/4” (214.0 cm) with refrigerator adjusted to its tallest position. Customize the installation if cutout height is more than 84 1/4” (214.0 cm) and no cabinets are installed above the refrigerator. The electrical outlet must be installed from 75 1/8” (190.8 cm) to 80 1/2” (204.5 cm) high and 0” to 21 1/2” (54.6 cm) from right side of cutout when facing cutout.

2

DIAGRAM A

A

B

C

2” X 4” Mounting Board

Receptacle Location

D

E

G

Lag bolt

Location

F

H

I

J

K

N

P

O

Water line entry

Q

L

R

3

M

ELECTRICAL REQUIREMENTS

ELECTRICAL SHOCK HAZARD

Electrically ground refrigerator.

Do Not use an extension cord.

Failure to follow these instructions could result in death, fire, or electrical shock

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70latest edition or Canadian Electrical Code C22.1-1982 and C22.2

No. 01982 (or latest edition), and all local codes and ordinances.

120 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is recommended that a separate circuit serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-type wall receptacle.

If codes permit a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate.

Do Not ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. Do Not have a fuse in the neutral or grounding circuit.

3-prong grounding plug

3-prong grounding-type wall receptacle grounding plug

WATER SUPPLY REQUIREMENTS

ELECTRICAL SHOCK HAZARD

Some water may remain in line. Electric drill must be grounded to prevent severe or lethal shock if water is in line and enters drill during use.

To calculate length of 1/4” (6mm) O.D. copper tubing needed:

Use only 1/4” (6 mm) copper tubing for water line. Do

Not install copper tubing in area where temperatures drop below 32 o F (0 o C). Before attaching copper tubing to refrigerator, flush at least 2 quarts (1.9 L) of water through the copper tubing and into a bucket to get rid of any particles in the water line.

line can be used if directions in Step 4 are carefully followed.

2. Measure distance from cold water line to refrigerator. Add 24” (61 cm) to this measurement.

To rough in water line:

3. Turn OFF main water supply. Turn ON nearest faucet long enough to clear line of water.

in water line.

Horizontal cold water line: Use grounded electric drill or hand drill to drill 3/16” (4.5 cm) hole in the line. This will keep sediment from collecting in valve.

piercing lance a maximum of 3/16” (4.5 cm). Align piercing lance over hole in water line.

Place both halves of saddle valve bracket against water line. Turn saddle valve handle clockwise until piercing lance enters hole in water line and is firmly seated. The saddle valve is now in the closed position. Tighten packing nut. Evenly and firmly tighten copper tubing could be crushed.

sleeve onto copper tubing. Insert end of copper tubing completely into valve outlet.

water through copper tubing into a bucket. Turn saddle valve handle clockwise to shut off water to copper tubing.

8. Route copper tubing into refrigerator area.

4

REFRIGERATOR INSTALLATION

EXCESSIVE WEIGHT HAZARD

Use two or more people to move and install refrigerator. Failure to follow this instruction can result in back or other injury.

Most of the refrigerator’s weight is at the top. Extra care is needed when moving the refrigerator to prevent tipping. Do Not lower the refrigerator against the shipping base when moving the shipping base. Do Not remove protective film until refrigerator is in operating position. All four leveling legs must contact the floor to support and stabilize the full weight.

The two 2” x 4” (5.1 cm x 10.2 cm ) mounting boards, for securing refrigerator to wall are attached to top rear of refrigerator. Save cardboard to protect walls when installing refrigerator.

1. Remove top and bottom strap.

2. Remove top cap.

3. Cut along dashes on carton rear with a utility knife extended 1/4” (.6 cm).

4. Remove carton, exterior packaging , and tape from lag screws. Do not remove nylon cord from power cord.

5. Remove shipping brackets from skid by removing 4 bolts with a 7/16” socket head screwdriver.

•Tilting refrigerator is not required to remove shipping brackets.

skid.

7. To avoid floor damage, use protective material.

Securing the refrigerator not cover the electrical outlet. board. Countersink the bolt heads into the 2” x 4” (5.1 cm x 10.2 cm) board using a wood bit. Bolt securely to wall studs. Predrill 1/4” (.6 cm) holes in second 2” x 4” (5.1 cm x 10.2 cm) and countersink bolt heads. Attach flush to first 2” x 4” (5.1 cm x 10.2 cm). If application does not have studs, such as a framed wall mount to the wall not surface, use a minimum 1/4” (.6 cm) diameter fasteners (not supplied). If cabinets are deeper than 24”, mounting board must be shimmed and structurally secured to the mounting board. Longer bolts are required to shim mounting board.

Grill

Assembly refrigerator does not run over the water line.

4. Repair any loose flooring in cutout.

Before moving the refrigerator in place, confirm the finished dimesions, electrical and plumbing locations, and minimum door and drawer clearances are accurate.

6. Position refrigerator in front of cutout.

assembly.

be shipped in the ON position and showroom switch will be in the OFF position. Display should flash. Press any key.

There is a 6 minute delay before the refrigerator starts.

Verify the position of each switch if there is no power to refrigerator.

Screws

Showroom

Switch

Power

Switch

5

refrigerator door. Tape cord in place.

kitchen cabinets. To avoid kitchen cabinet damage, place cardboard between kitchen cabinets and refrigerator. Push cardboard back with refrigerator and remove cardboard when refrigerator is in place. Remove power cord slack by pulling nylon cord straight out while pushing refrigerator completely into place.

Power and nylon cords will rest along refrigerator side.

Nylon

Cord clockwise to raise refrigerator and counterclockwise to lower refrigerator. Rotate leveling feet until firmly in place against floor.

leveling wheels.

Wall Stud

Wall Board or Plaster

Mounting

Board

Access to

Lag Bolts assembly and set aside.

extension socket. See Diagram A on page 3. cord can be flush refrigerator.

16. Replace the grill assembly.

Lag Bolts Lag Bolt with

Extended Shaft

Lag Bolt mounting

2 X 4 to wall

6

Leveling Wheel

Bolts

Leveling Feet

WATER CONNECTION

The garden hose fitting, compression nut, and sleeve are located in the literature packet. The water filtration system is shipped in the crisper drawer. bucket.

brass nut on copper tubing to garden hose fitting. Connect garden hose fitting to water valve inlet port. Confirm copper tubing is secure by pulling on copper tubing.

Repeat this process until no leaks exist. Completely turn on water supply to refrigerator.

4. Verify drain pain is installed and aligned.

•Drain pan must be pushed past and over initial stopping point.

panel to be removed.

6. After 24 hours checks for leaks. If unit is leaking, correct leaks. Repeat this process until no leaks are found.

DOOR STOP ADJUSTMENT

1. Remove center grill blade from the top air grill.

screw driver. Pull assembly forward.

accessible. Shoulder screws should be in 110 o position.

door opening o or

120 o door opening position.

120 o position

110 o position

90 o position

Door Stop Arm

HINGE ADJUSTMENT

Verify proper door alignment. Only the top hinge is adjustable.

1. Remove the center grill blade from the top air grill.

magnetic screw driver. Pull assembly forward.

3. Loosen the (4) top hinge screws.

4. Align refrigerator door by lifting.

5. Tighten screws.

Top Hinge

7

Top Hinge

Screws

BASIC SPECIFICATIONS AND DIMENSIONS

DESCRIPTION

Overall Width

VCBB360

36 5/16” (92.2 cm)

Overall Height from Bottom

Overall Depth from Rear

Cutout Width

Cutout Height

Cutout Depth

Electrical Requirements

Maximum Amp Usage

Min. 83 1/4” (211.5 cm) to Max. 84 1/4” (214.0 cm)

To side trim

To front of top grill

To end of handle bracket

22 3/16” (56.3 cm)

24 11/16” (62.7 cm)

27 1/4” (69.2 cm)

35 7/8” (91.1 cm)

84” (213.4 cm)

24” (61.0 cm)

120 volt, 60 Hz, 15 amp circuit; 3-wire cord with grounded

3-prong plug attached to product.

8.2 amps

Inlet Water Requirements

Overall Interior Dimensions

•Refrigerator

•Freezer

•Total Capacity

Approximate Shipping Weight

1/4” copper tubing inlet waterline

15.2 cu. ft.

5.7 cu. ft.

20.9 cu. ft.

470 lbs. (211.5 kg)

TOP VIEW

58 7/16”

(148.4 cm)

90 o

8

Min. 83 1/4”

(211.5 cm) to

Max. 84 1/4”

(214.0 cm)

FRONT VIEW

36 5/16”

(92.2 cm)

51 7/16”

(130.7 cm)

23”

(58.4 cm)

9

SIDE VIEW

24 11/16”

(62.7 cm)

Min. 83 1/4”

(211.5 cm) to

Max. 84 1/4”

(214.0 cm)

58 3/8” (148.3 cm)

22 3/16”

(56.4 cm)

10

WIRING DIAGRAM

BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER

WARNING:

ELECTRICAL

GROUNDING

INSTRUCTIONS

This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. DO

NOT CUT OR

REMOVE THE

GROUNDING REFER ONLY TO FEATURES WHICH ARE EQUIPPED WITH THIS UNIT.

11

F1692

Viking Range Corporation

111 Front Street

Greenwood, Mississippi (MS) 38930 USA • (601) 455-1200

Specifications subject to change without notice (PS599VR)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement