MS430580: 3R Retimer Module (FE, 1GbE

MICROSENS
Media Converter/Signal Repeater
Module
Overview
Media Converter/Signal Repeater module is a part of MICROSENS 10G Transport
Platform, a high performance and flexible carrier-class transmission system. The 10G
Transport Platform enables increasing transport capacitities in CWDM, DWDM and SDH
networks. The use of wide range TDM modules permits to reduce the number of
necessary wavelengths and to decrease the overall cost of the application. Ethernet
over SDH modules enable using exisiting SONET/SDH infractructure for IP transmission.
The general features of the system:
•
19“ 2U Chassis with 5 module slots and management card
•
Max. 5x single size modules f.ex. 2x double size + 1x single size module
•
Hot swappable modules & power supplies
•
Redundant power supplies with -48 VDC input (opt. 230 VAC)
•
Exchangeable air- and filter module
•
Wide range of functional xWDM and TDM modules available
The functional modules of 10G Transport Platform include:
•
TDM 8x GBE or 8x GFC to 10G/OC-192/STM-64
•
TDM 5x GBE or 5x 2GFC to OC-192/STM-64
•
TDM 4x OC-48/STM-16 to 10G/OC-192/STM-64
•
TDM 2x GBE and 2x GFC to OC-48/STM-16
•
10G transponder with 3R, XFP and fixed Laser Versions
•
10G protocol converter 10G LAN to 10G WAN (OC-192/STM-64)
•
DWDM MUX/DeMUX, OADMs, EDFAs
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 2/29
Introduction
Media Converter/Signal Repeater range is a MICROSENS 10G Transport Platform
allowing Media conversation and Retiming, Reshaping and Retransmission of the signal
from 155 Mb/s up to 2.5 Gb/s.
Features
•
Media Converter
•
Signal repeater with 3R functions:
•
−
Retiming
−
Reshaping
−
Retransmitting
Supports the following protocols:
−
OC-3/STM1
−
OC-12/STM4
−
OC-48/STM16
−
GbE
−
1GFC
−
2GFC
−
Fast Ethernet
−
OC-3/STM1-FEC
−
OC-12/STM4-FEC
−
OC-48/STM16-FEC
•
SFP for Line 1 and Line 2 physical interface
•
Digital Diagnostic Monitoring information from SFP
System description
The block diagram for the MS430580M is given in Figure 1. The MS430580M is a bidirectional device that offers twice the same media convertion/regeneration
functionnality
•
From one interface input signal (Line 1 or Line 2) to one interface output signal
(Line 2 or Line 1).
The MS430580M includes also several sections composed of
•
Controller block, providing interfacing to the MS module series chassis controller
board hosting the SNMP Agent.
•
Power supplies: generates different internal power supplies from the -48V of the
MICROSENS chassis backplane
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
•
page 3/29
Front panel LEDs indicating the status of the interfaces and the MS430580M
common functions
Figure 1: MS430580M Block diagram.
Media converter / Regeneration description
The received signal is first converted from optical signal to electrical signal through the
SFP interface. Then the electrical signal is converted to an optical signal through the
second SFP interface.
These two conversions (optical to electrical and then electrical to optical) perform a
retiming, reshaping and retransmission of the optical signal from the Line 1 (or Line 2)
input to the Line 2 (or Line 1) output.
Upon the SFP type used on Line 1 and Line 2, it is possible to perform, together with
the signal regeneration, a media convertion (850nm to 1310nm, CWDM to DWDM, etc).
The following alarms are provided to the controller block:
Line 1 and Line 2 Loss of incoming Signal
Line 1 and Line 2 Laser Shutdown
The following measures are provided to the controller block:
•
SFP temperature in °C
•
SFP voltage in V
•
SFP receive power in dBm
•
SFP transmit power in dBm
•
SFP laser pump current (bias) in mA
Clock Generation Unit
The Clock Generation Unit provides the reference clock to the Line 1 and Line 2 optical
interfaces according to the parameter given by the Controller Block. The reference
clock is internal to the MS430580M and has a stability of +/- 50 ppm. The Clock
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 4/29
Generation Unit can provide a reference clock to supLine 1 bitrate from 125 Mb/s up to
2.67 Gb/s. Therefore the MS430580M can support the following protocols:
Protocol
Bitrate
Fast Ethernet
125 Mb/s
OC-3/STM1
155.52 Mb/s
OC-3/STM1-FEC
166.62 Mb/s
OC-12/STM4
622.08 Mb/s
OC-12/STM4-FEC
666.51 Mb/s
1GFC
1.0625 Gb/s
GbE
1.25 Gb/s
2GFC
2.125 Gb/s
OC48/STM16
2.448 Gb/s
OC48/STM16-FEC
2.666 Mb/s
Controller Block
The controller block is composed of a microprocessor associated with Flash and RAM
memories. The controller block collects information from different functional blocks
and configures the HW according to a configuration file received. The raw information
(alarms, monitoring, inventory) generated by the HW are processed by the
microprocessor and delivered to the MICROSENS chassis Management Board as high
level consolidated data.
Interface Specifications
Line 1 and Line 2 interfaces are provided by SFP transceivers. The optical characteristics
are therefore given in the data sheet of the SFPs plugged into the MS430580M module.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 5/29
SNMP User Manual
Access Configuration
Certain aspects of the Line 1 and Line 2 are user modifiable. In the following
procedures the modifications are indicated at bit level. Take note of your SNMP
manager’s requirements. For example setting the bits 6, 3, 2 and 0 to 1 will yield the
following values:
Line 1 optical interface Configuration
One object is dedicated to the Line 1 optical interface configuration:
•
ms430580mCfgportaTrscvCtrl
This allows the configuring of the initialisation of the Line 1 SFP laser state.
Location: \microsens\modulems430580m\ms430580mConfig\ms430580mCfgStartup\
ms430580mtableclientStartup\
The following table details the meaning of each bit as well as the default values:
ms430580mCfgportaTrscvCtrl
Bit
Default value
Bit Name
Description
Bit 0
0
Line 1 SFP Laser Off
Line 1 SFP Laser state:
0: SFP Laser ON
1: SFP Laser OFF
Bit 7-1
0000000
Reserved
Set to Default value
Bit 15-8
00000000
Reserved
Set to Default value
Line 2 optical interface Configuration
One object is dedicated to the Line 2 optical interface configuration:
•
ms430580mCfgportbTrscvCtrl
This allows the configuring of the initialisation of the Line 2 SFP laser state.
Location: \microsens\modulems430580m\ms430580mConfig\ms430580mCfgStartup\
ms430580mtablelineStartup\
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 6/29
The following table details the meaning of each bit as well as the default values:
ms430580mCfgportbTrscvCtrl
Bit
Default value
Bit Name
Description
Bit 0
0
Line 2 SFP Laser Off
Line 2 SFP Laser state:
0: SFP Laser ON
1: SFP Laser OFF
Bit 7-1
0000000
Reserved
Set to Default value
Bit 15-8
00000000
Reserved
Set to Default value
Client/Line bitrate Configuration
One object is dedicated to the client/line bitrate configuration:
•
ms430580mCfgbitrateSelect
This allows the configuring of the bitrate for the Line 1 and Line 2.
Location: \microsens\modulems430580m\ms430580mConfig\ms430580mCfgStartup\
ms430580mtablelineStartup\
The following table details the meaning of each bit as well as the default values:
ms430580mCfgprotocolSelect
Bit
Default
Bit Name
value
Description
Bit 3-0
0000
Bitrate selection
0: 2.488 Gb/s (OC-48/STM16)
1: 1.25 Gb/s (GbE)
2: 622.08 Mb/s (OC-12/STM4)
3: 155.52 Mb/s (OC-3/STM1)
Line 1 and Line 2 bitrate 4: 2.125 Gb/s (2GFC)
5: 1.0625 Gb/s (1GFC)
7: 125 Mb/s (Fast Ethernet)
8: 2,666 Mb/s (OC-48/STM16-FEC)
9: 666.51 Mb/s (OC-12/STM4-FEC)
10: 166.62 Mb/s (OC-3/STM1-FEC)
Bit 7-4
0000
Reserved
Set to Default value
Reserved
Set to Default value
Bit 15-8 00000000
How to modify the Configuration
The following procedure outlines how to modify any configuration. This can be
performed at any time, keeping in mind that the cold reset will affect the traffic.
Note
This is module type dependant. Consu lt the table in the Description section
to determine if it is applicable or not. The following modifications may be
achieved by using control objects in:
...\microsens\modulems430580m\ms430580mcontrolsWrite\
However modifications made in this way are lost following a reset.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 7/29
The Line and Client configuration modification can be performed at the same time and
applied at the same time with one reset. Traffic implications will depend on your choice
of reset.
Procedure
•
Ensure that the correct module is selected for management. Consult the object:
− mgnt2GigmSelectedBoard
Location:…\microsens\mgnt2\mgnt2SNMPAgentData\
mgnt2ModulesManagement\
•
Change if necessary.
•
Determine a value corresponding to the configuration profile you require.
•
Perform an SNMP SET to write the value corresponding to the required
configuration profile into the SNMP agent.
•
Perform a SET to “on” the object:
− ms430580mCfgWriteConfiguration
Location: ...\microsens\modulems430580m\ms430580mConfig\
This will load the new configuration from the SNMP agent to the modules RAM.
•
Transfer the new configuration into the module using the object:
−
ms430580mCtrlConfFlash
Location:
...\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther\
ms430580mCtrlsynth0\
•
Restart the module using a cold reset or by powering down/up to apply the
configuration modification. Reset information can be found in the Software
management section.
Note
At that point, configuration 2 becomes the default configuration of the MS
module.
End procedure
Management
Inventory
Accessing the inventory allows the user to obtain information on the modules current
hardware and software status. The objects described below may be found in:
…\microsens\modulems430580m\ms430580mri\
Note
Before consulting the inventory ensure that the correct module is selected.
Consult the object mgnt2GigmSelectedBoard
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 8/29
Location…
\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
Change if necessary.
The following are inventory examples:
ms430580mRinvHwPlatform
This object returns information relating to the hardware platform.
MICROSENS PLATFORM
Vendor: MICROSENS
Mnemonic: MS430580M
Part Number: 2MS00072AAAA01
Serial Number: 000010
Date Code (yymmddww): 06160104
ms430580mRinvReloadInventory
Setting this object triggers an inventory read from the module to the agent,
(refresh).
ms430580mRinvSwPlatform
Module software package description.
SW PACKAGE
Mnemonic: MS430580M
Part Number: 5MS07000AAAA01
Release date(yymmdd): 060509
SW Part Number: 3SW07001AAAA
Version Number: 02
Release date(yymmdd): 060510
ms430580mRinvPortASFP
This object returns information relating to the Line 1 SFP in the Module with the
following headings:
Vendor:
Part Number:
Revision Level:
Serial Number:
Date Code (yymmdd):
ms430580mRinvPortBSFP
This object returns information relating to the Line 2 SFP in the Module with the
following headings:
Vendor:
Part Number:
Revision Level:
Serial Number:
Date Code (yymmdd):
Alarms
In order to retrieve Alarm status information a polling mechanism must be put in place.
The appearance of a trap message signals the occurrence of an Alarm.
The following table lists the possible alarms and recommended actions:
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 9/29
NAME
DESCRIPTION
ACTION
ms430580mAlmModuleGlobFailure
Module Failure: This OID is set on Correlate all alarms. If Alarm
detection of a failure originating persists change the module.
from the MS module
ms430580mAlmSynUnlock
Synthesizer not locked: This OID
indicates that the frequency
synthesizer is not locked.
No action information only.
ms430580mAlmDefFuseA
Fuse A fail: This OID indicates
that the fuse of the power input
A is in fail condition
Correlate all alarms. If Alarm
persists change the module.
ms430580mAlmDefFuseB
Fuse B Fail: This OID indicates
that the fuse of the power input
B is in fail condition
Correlate all alarms. If Alarm
persists change the module.
ms430580mAlmLine1TxPwLowWng
TRSCV 1 Tx Power Low
warning: Warning indicating
that the transceiver output
power of Line 1 is lower than
the threshold value written in
the transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TxPwrHighWng
TRSCV 1 Tx Power High
warning: Warning indicating
that the transceiver output
power of Line 1 is higher than
the threshold value written in
the transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance procedures.
ms430580mAlmLine1TxBiasLowWng
TRSCV 1 Bias Low warning:
Warning indicating that the
transceiver laser bias current of
Line 1 is lower than the
threshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TxBiasHighWng
TRSCV 1 Bias High warning:
Warning indicating that the
transceiver laser bias current of
Line 1 is higher than the
threshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TempLowWng
TRSCV 1 Temp Low warning:
Warning indicating that the
transceiver temperature of Line
1 is lower than the threshold
value written in the transceiver
EEPROM
Correlate all warnings and Alarms.
Carry out necessary maintenance
procedures.
ms430580mAlmLine1TempHighWng
TRSCV 1 Temp High warning:
Warning indicating that the
transceiver temperature of Line
1 is higher than the threshold
value written in the transceiver
EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1RxPwrLowWng
TRSCV 1 Rx Power Low
warning: Warning indicating
that the transceiver input power
of Line 1 is lower than the
threshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 10/29
NAME
DESCRIPTION
ACTION
ms430580mAlmLine1RxPwrHighWng
TRSCV 1 Rx Power High
Correlate all warnings. Carry out
warning: Warning indicating
necessary maintenance
that the transceiver input power procedures.
of Line 1 is higher than the
threshold value written in the
transceiver EEPROM
ms430580mAlmLine1CdrLossofsignal
Line 1 CDR Loss of Signal: This
OID indicates that a Loss
of electrical signal is detected
on the Line 1 CDR
Check client status. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1CdrLossoflock
Line 1 CDR Loss of Lock: This
OID indicates that the Line 1
CDR is not locked
Check client status. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1CdrRefAbsent
Line 1 CDR Reference clock
absent: This OID indicates that
the CDR reference clock is
absent on Line 1
No action information only.
ms430580mAlmLine1TxPwrLowAla
TRSCV 1 Tx Power Low: Alarm
Correlate all. Carry out necessary
indicating that the transceiver
maintenance procedures.
output power of Line 1 is lower
than the threshold value written
in the transceiver EEPROM
ms430580mAlmLine1TxPwrHighAla
TRSCV 1 Tx Power High: Alarm
Correlate all Alarms. Carry out
indicating that the transceiver
necessary maintenance
output power of Line 1 is higher procedures.
than the threshold value written
in the transceiver EEPROM
ms430580mAlmLine1TxBiasLowAla
TRSCV 1 Bias Low :Alarm
indicating that the transceiver
laser bias current of Line 1 is
lower than the threshold value
written in the transceiver
EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TxBiasHighAla
TRSCV 1 Bias High: Alarm
indicating that the transceiver
laser bias current of Line 1 is
higher than the threshold value
written in the transceiver
EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TempLowAla
TRSCV 1 Temp Low: Alarm
Correlate all Alarms. Carry out
indicating that the transceiver
necessary maintenance
temperature of Line 1 is lower
procedures.
than the threshold value written
in the transceiver EEPROM
ms430580mAlmLine1TempHighAla
Correlate all Alarms. Carry out
TRSCV 1 Temp High: Alarm
necessary maintenance
indicating that the transceiver
temperature of Line 1 is higher procedures.
than the threshold value written
in the transceiver EEPROM
ms430580mAlmLine1RxPwrLowAla
Correlate all Alarms. Carry out
TRSCV 1 Rx Power Low: Alarm
necessary maintenance
indicating that the transceiver
procedures.
input power of Line 1 is lower
than the threshold value written
in the transceiver EEPROM
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 11/29
NAME
DESCRIPTION
ACTION
ms430580mAlmLine1RxPwrHighAla
TRSCV 1 Rx Power High: Alarm
Correlate all Alarms. Carry out
indicating that the transceiver
necessary maintenance
input power of Line 1 is higher
procedures.
than the threshold value written
in the transceiver EEPROM
ms430580mAlmLine1TrscvAbsent
Line 1 SFP not plugged: This
OID indicates that the
transceiver module 2 is not
present.
Plug in the Optical Module. If
Alarm
persists change the optical
component.
ms430580mAlmLine1TrscvDdmAbsent
DDM supported on Line 1 SFP:
This OID indicates that the
transceiver module 1 does not
support Digital Diagnostic
Monitoring Functions
If SFP supports DDM change the
SFP, else ignore.
ms430580mAlmLine1HwFail
Line 1 HW Failure: This OID
indicates a hardware failure on
the Line 1
Correlate relevant alarms. Carry
out
necessary maintenance
procedures.
ms430580mAlmLine1TrscvLsd
Line 1 SFP optical TX ON: This
OID indicates the optical output
power is off on Line 1
No action information only.
ms430580mAlmLine1TrscvDdmWarning
Warning DDM on Optical
Module 1: This OID indicates a
warning is present coming out
of optical interface DDM on
Line 1
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1TrscvDdmAlm
Alarm DDM on Optical Module
1: This OID indicates an alarm is
present coming out of optical
interface DDM on Line 1
Correlate all alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine1Fail
Line 1 Failure: This OID
indicates a failure on the Line 1
Correlate relevant alarms. Carry
out necessary maintenance
procedures.
ms430580mAlmLine1LasFail
Line 1 SFP Tx Failed: This OID
indicates that the transmitter
fails for the transceiver plugged
into the Line 1 (this alarm
reports the transmitter failure
alarm generated by the
transceivers)
Correlate relevant alarms. If
Alarm
persists replace the Client SFP.
ms430580mAlmLine1Los
Loss of Optical signal on Line 1: Check client status. Carry out
This OID indicates that no signal necessary maintenance
is present on thetransceiver 1
procedures.
ms430580mAlmLine2TxPwLowWng
TRSCV 2 Tx Power Low warning: Correlate all warnings. Carry out
necessary maintenance
Warning indicating that the
procedures.
transceiver output power of
Line 2 is lower than the
threshold value written in the
transceiver EEPROM
ms430580mAlmLine2TxPwrHighWng
TRSCV 2 Tx Power High
warning :Warning indicating
that the transceiver output
power of Line 2 is higher than
the threshold value written in
the transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 12/29
NAME
DESCRIPTION
ACTION
ms430580mAlmLine2TxBiasLowWng
TRSCV 2 Bias Low warning:
Warning indicating that
thetransceiver laser bias current
ofLine 2 is lower than
thethreshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TxBiasHighWng
TRSCV 2 Bias High warning:
Correlate all warnings. Carry out
Warning indicating that the
necessary maintenance
procedures.
transceiver laser bias current of
Line 2 is higher than the threshold
value written in the transceiver
EEPROM
ms430580mAlmLine2TempLowWng
TRSCV 2 Temp Low warning:
Warning indicating that the
transceiver temperature of Line
2 is lower than the threshold
value written in the transceiver
EEPROM
Correlate all warnings and
Alarms.
Carry out necessary maintenance
procedures.
ms430580mAlmLine2TempHighWng
TRSCV 2 Temp High warning:
Warning indicating that the
transceiver temperature of Line
2 is higher than the threshold
value written in the transceiver
EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2RxPwrLowWng
TRSCV 2 Rx Power Low warning:
Warning indicating that the
transceiver input power
of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2RxPwrHighWng
TRSCV 2 Rx Power Highwarning:
Warning indicating that the
transceiver input power
of Line 2 is higher than the
threshold value written in the
transceiver EEPROM
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2CdrLossofsignal Line 2 CDR Loss of Signal: This OID Check client status. Carry out
indicates that a Lossof electrical
necessary maintenance
signal is detectedon the Line 2
procedures.
CDR
ms430580mAlmLine2CdrLossoflock
Line 2 CDR Loss of Lock: This
OID indicates that the Line 2
CDR is not locked
Check client status. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2CdrRefAbsent
Line 2 CDR Reference clock
absent: This OID indicates that
the CDR reference clock is
absent on Line 2
No action information only.
ms430580mAlmLine2TxPwrLowAla
TRSCV 2 Tx Power Low: Alarm
indicating that the transceiver
output power of Line 2 is lower
than the threshold value written
in the transceiver EEPROM
Correlate all. Carry out necessary
maintenance procedures.
ms430580mAlmLine2TxPwrHighAla
Correlate all Alarms. Carry out
TRSCV 2 Tx Power High: Alarm
necessary maintenance
indicating that thetransceiver
procedures.
output power ofLine 2 is higher
than thethreshold value written in
thetransceiver EEPROM
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 13/29
NAME
DESCRIPTION
ACTION
ms430580mAlmLine2TxBiasLowAla
TRSCV 2 Bias Low: Alarm
indicating that the transceiver
laser bias current of Line 2 is
lower than the threshold value
written in the transceiver
EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TxBiasHighAla
TRSCV 2 Bias High: Alarm
indicating that the transceiver
laser bias current of Line 2 is
higher than the threshold value
written in the transceiver
EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TempLowAla
TRSCV 2 Temp Low: Alarm
indicating that the transceiver
temperature of Line 2 is lower
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TempHighAla
TRSCV 2 Temp High: Alarm
indicating that the transceiver
temperature of Line 2 is higher
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2RxPwrLowAla
TRSCV 2 Rx Power Low: Alarm
indicating that the transceiver
input power of Line 2 is lower
than the threshold value written
in the transceiver EEPROM
Correlate all Alarms. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2RxPwrHighAla
TRSCV 2 Rx Power High: Alarm
Correlate all Alarms. Carry out
indicating that the transceiver
necessary maintenance
input power of Line 2 is higher
procedures.
than the thresholdvalue written in
the transceiverEEPROM
ms430580mAlmLine2TrscvAbsent
Line 2 SFP not plugged: This
OID indicates that the
transceiver module 2 is not
present
ms430580mAlmLine2TrscvDdmAbse
nt
DDM supported on Line 2 SFP: This If SFP supports DDM change the
OID indicates that the
SFP, else ignore.
transceiver module 2 does not
support Digital Diagnostic
Monitoring Functions
ms430580mAlmLine2HwFail
Line 2 HW Failure: This OID
indicates a hardware failure on
the Line 2
Correlate relevant alarms. Carry
out
necessary maintenance
procedures.
ms430580mAlmLine2TrscvLsd
Line 2 SFP optical TX ON: This
OID indicates the optical output
power is off on Line 2
No action information only.
Plug in the Optical Module. If
Alarm
persists change the optical
component.
ms430580mAlmLine2TrscvDdmWarn Warning DDM on OpticalModule
ing
2: This OID indicates awarning is
present coming outof optical
interface DDM onLine 2
Correlate all warnings. Carry out
necessary maintenance
procedures.
ms430580mAlmLine2TrscvDdmAlm
Correlate all alarms. Carry out
necessary maintenance
procedures.
Alarm DDM on Optical Module 2:
This OID indicates an alarm is
present coming out of optical
interface DDM on Line 2
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 14/29
NAME
DESCRIPTION
ACTION
ms430580mAlmLine2Fail
Line 2 Failure: This OID
indicates a failure on the Line 2
Correlate relevant alarms. Carry
out necessary maintenance
procedures.
ms430580mAlmLine2LasFail
Line 2 SFP Tx Failed: This OID
indicates that the transmitter
fails for the transceiver plugged
into the Line 1 (this alarm
reports the transmitter failure
alarm generated by the
transceivers)
Correlate relevant alarms. If
Alarm
persists replace the Client SFP.
ms430580mAlmLine2Los
Loss of Optical signal on Line 2:
This OID indicates that no
signal is present on the
transceiver 2
Check client status. Carry out
necessary maintenance
procedures.
Traps
A trap is an unsolicited, asynchronous event that the MGNT generates to indicate a
status change; e.g.: a trap is generated on the detection of a start of an alarm and an
end of an alarm.
Note
It is important to set the IP address of t he manager correctly in order to receive
the traps.
There are two types of trap:
•
Line 1 traps originating from Line 1 problems.
•
Line 2 traps originating from Line 2 problems.
These are further categorised as follows:
•
Critical: –Traffic affecting, demanding immediate attention.
•
Urgent: –Indicating that maintenance is required.
•
Non-urgent: – Warning, information, non traffic affecting origin DDM.
The binding information that accompanies a trap is for information only and should be
used to make the alarm polling more efficient.
The following table lists the possible traps originating from a MS430580M and their
contributing alarms.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 15/29
MS430580MTraps
Name
Description
ms430580mPortaTrapNotUrgentGoesOn
Not urgent Line 1 fault is activated
Bindings
Action
Consult Alarms. Correlate warnings
ms430580mAlmPortaTrscvDdmWarning originating from the line. Carry out
ms430580mtrapBoardNumber
necessary maintenance
procedures.
ms430580mPortaTrapNotUrgentGoesOff ms430580mAlmPortaTrscvDdmWarning
No Action.
ms430580mtrapBoardNumber
Not urgent Line 1 fault disappeared
ms430580mAlmPortaTrscvDdmAlm
ms430580mtrapBoardNumber
Consult Alarms. Correlate alarms
originating from the line. Carry out
necessary maintenance
procedures.
ms430580mAlmPortaTrscvDdmAlm
ms430580mtrapBoardNumber
No Action.
ms430580mAlmPortaFail
ms430580mAlmPortaHwFail
ms430580mtrapBoardNumber
Consult Alarms. Correlate alarms
originating from the MS module.
Carry out necessary maintenance
procedures.
ms430580mAlmPortaFail
ms430580mAlmPortaHwFail
ms430580mtrapBoardNumber
No Action.
ms430580mPortaTrapUrgentGoesOn
Urgent Line 1 fault is activated
ms430580mPortaTrapUrgentGoesOff
Urgent Line 1 fault disappeared
ms430580mPortaTrapCritGoesOn
Critical Line 1 fault is activated
ms430580mPortaTrapCritGoesOff
Critical Line 1 fault disappeared
ms430580mPortbTrapNotUrgentGoesOn
Not urgent Line 2 fault is activated
Consult Alarms. Correlate warnings
ms430580mAlmPortbTrscvDdmWarning originating from the port. Carry out
ms430580mtrapBoardNumber
necessary maintenance
procedures.
ms430580mPortbTrapNotUrgentGoesOff ms430580mAlmPortbTrscvDdmWarning
No Action.
ms430580mtrapBoardNumber
Not urgent Line 2 fault disappeared
ms430580mAlmPortbTrscvDdmAlm
ms430580mtrapBoardNumber
Consult Alarms. Correlate alarms
originating from the port. Carry out
necessary maintenance
procedures.
ms430580mAlmPortbTrscvDdmAlm
ms430580mtrapBoardNumber
No Action.
ms430580mAlmPortbFail
ms430580mAlmPortbHwFail
ms430580mtrapBoardNumber
Consult Alarms. Correlate alarms
originating from the MS module.
Carry out necessary maintenance
procedures.
ms430580mAlmPortbFail
ms430580mAlmPortbHwFail
ms430580mtrapBoardNumber
No Action.
ms430580mAlmDefFuseA
ms430580mAlmDefFuseB
ms430580mtrapBoardNumber
Consult Alarms. Correlate alarms
originating from the MS module.
Carry out necessary maintenance
procedures.
ms430580mAlmDefFuseA
ms430580mAlmDefFuseB
ms430580mtrapBoardNumber
No Action.
ms430580mPortbTrapUrgentGoesOn
Urgent Line 2 fault is activated
ms430580mPortbTrapUrgentGoesOff
Urgent Line 2 fault disappeared
ms430580mPortbTrapCritGoesOn
Critical Line 2 fault is activated
ms430580mPortbTrapCritGoesOff
Critical Line 2 fault disappeared
ms430580mPowerTrapUrgentGoesOn
Urgent power fault is activated
ms430580mPowerTrapUrgentGoesOff
Urgent power fault disappeared
Software Management
Hardware Reset
A Hardware reset may be performed on the MS430580M. This operation is performed
by extracting and re-inserting the MS430580M in the M430500M Chassis. The following
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 16/29
procedure describes the steps to follow to perform a hardware reset of the MS430580M
module.
Procedure
•
Using a flat head screwdriver, loosen the two holding screws on the frontplate,
located at the top right-hand and bottom left-hand corners.
•
Slide out the module for few centimetres
•
Wait for 15 seconds
Warning
The wait time of 15 seconds is mandato ry to insure to correct detection of the
module extraction and re-insertion. Re-inserting the MS430580M module to
early may casue communication problem between the MS430580M module and
the management board.
•
Slide in the module in the MS430500M chassis slot.
•
Check the module has been correctly detected by the MGNT board using the
object:
− mgnt2GigmBoardTable
Location:
…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
Note
Use the MS module series chassis User Manu al SNMP for details about this OID.
•
Using a flat head screwdriver; tighten the holding screw on the frontplate of
module.
End procedure
Software Cold Reset
A software cold reset loads the software from the selected bank and the configuration
into the operational memory. The configuration from conf2 is the first choice, if conf2
is empty then conf1; if conf1 is empty the default hardwired configuration is loaded.
This reset is traffic affecting and takes 20 seconds to complete. The following outlines
the steps to perform a Software cold reset on a MS430580M module:
Procedure
•
Ensure that the correct module is selected for management. Consult the object:
− mgnt2GigmSelectedBoard
Location:
…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
•
Change if necessary.
•
Start the reset:
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 17/29
− Set to “on “the object: ms430580mCtrlColdReset
Location:
…\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther
\ms430580mCtrlswMgnt
Once this change is recognised the module starts to reset. Visual indication:
The colour sequence of the SW led on the front panel of the module during a reset is:
•
Green on > Red On > Green/Orange blinking > Green on
Under normal conditions all LEDs return to green when the reset is complete. The
status of the Line and Client Port LEDs depend on the local configuration. Refer to LED
status table. The duration of a Software Cold Reset on a MS430580M is approximately
25 seconds.
End procedure
Software Warm Reset
A warm reset only loads the selected software into the operational memory. This reset
has no effect on the traffic takes approximately 20 seconds to complete.
Procedure
•
Ensure that the correct module is selected for management. Consult the object:
− mgnt2GigmSelectedBoard
Location:
…\microsens\mgnt2\mgnt2SNMPAgentData\ mgnt2ModulesManagement\
•
Change if necessary
•
Start the reset, set to “on “the object:
− ms430580mCtrlWarmReset
Location:
...
\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther\m
s430580mCtrlswMgnt
Once this change is recognised the module starts to reset. Visual indications:
The colour sequence of the SW led on the front panel of the module during a Warm
Reset is:
• Green on > Red on > Green on
Under normal conditions all LEDs return to green when the reset is complete. The
status of the Line and Client Port LEDs depend on the local configuration.
End procedure
Monitoring
In order to manage the various measurements available a polling mechanism is
required, thereby allowing the uploading of several physical parameters such as SFP
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 18/29
temperature, optical input power, etc. provided by the DDM. The DDM or Digital
Diagnostic Monitoring in each SFP provides real-time monitoring of voltage and
temperature readings of each optical component, together with thresholds and alarms.
A description of all the available measurements can be found in Appendixes.
The following describes the method of interpretation of the different types of
measurements:
Temperature
The object:
•
ms430580mMesrportaTemperature
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\
The object:
•
ms430580mMesrportbTemperature
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
Give the temperature value of the SFP plugged into Line 1 and Line 2, read from the
Digital Diagnostic Monitoring (Unit = °C) . The following formula must be applied to
the returned value in order to obtain the actual temperature:
T (°C) = MSB + LSB/256
Parameter
Meaning
Format
MSB
Most Significant Byte
Signed Byte
LSB
Least Significant Byte
Unsigned Byte
For example:
A listing of ms430580mMesrportaTemperature outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaTemperature (integer) 11066
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 11066. This is a decimal value,
the Hexadecimal equivalent is: 2B3A
2B (hex) = 43 (dec) and 3A (hex) = 58 (dec)
So applying the formula: T = 43 + 58/256
Gives an actual temperature of: + 43.23°C
Voltage
The object:
•
ms430580mMesrportaVolt
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\
The object:
•
ms430580mMesrportbVolt
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 19/29
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
Give the 3V3 voltage value of the SFP plugged into Line 1 and Line 2, read from the
Digital Diagnostic Monitoring (Unit = V). The following formula must be applied to the
returned value in order to obtain the actual voltage:
3V3 (Volts) = AV/10000
Parameter
Meaning
Format
AV
Article Value
Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaVolt outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaVolt (integer) 33094
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 33094.
So applying the formula: 3V3 (Volts) = 33094/10000
Gives an actual value of: 3.3094V
Bias
The object:
•
ms430580mMesrportaTxBias
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\
The object:
•
ms430580mMesrportbTxBias
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
Give the bias value of the SFP plugged into Line 1 and Line 2, read from the Digital
Diagnostic Monitoring (Unit = mA). The following formula must be applied to the
returned value in order to obtain the bias:
Bias(mA) = AV/500
Parameter
Meaning
Format
AV
Article Value
Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaTxBias outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaTxBias (integer) 11046
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 11046.
So applying the formula: Bias(mA) = 11046/500
Gives an actual value of: 22.092mA
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 20/29
Transmit Power
The object:
•
ms430580mMesrportaTxPower
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\
The object:
•
ms430580mMesrportbTxPower
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
This article gives the transmit power value of the SFP plugged into Line 1 and Line 2,
read from the Digital Diagnostic Monitoring (Unit = dBm). The actual Transmit Power
in dBm or mW can be obtained by applying the following formula to the returned
value:
Tx_Pwr(mW) = AV/10000
Tx_Pwr(dBm) = 10xlog(AV/10000)
Parameter
Meaning
Format
AV
Article Value
Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaTxPower outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaTxPower (integer) 30
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 30.
So applying the formula: Tx_Pwr(mW) = 30/10000
Gives an actual value of: 0.003mW
And applying the formula: Tx_Pwr(dBm) = 10xlog(30/10000)
Gives an actual value of: -25.23dBm
Receive Power
The object:
•
ms430580mMesrportaRxPower
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrClient\
The object:
•
ms430580mMesrportbRxPower
Location:..\microsens\modulems430580m\ms430580mmeasures\
ms430580mMesrLine\
This article gives the receive power value of the SFP plugged into Line 1 and Line 2,
read from the DDM (Digital Diagnostic Monitoring) (Unit = dBm). The actual Receive
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 21/29
Power in dBm or mW can be obtained by applying the following formula to the
returned value:
Rx_Pwr(mW) = AV/10000
Rx_Pwr(dBm) = 10xlog(AV/10000)
Parameter
Meaning
Format
AV
Article Value
Unsigned word (16 bits)
For example:
A listing of the ms430580mMesrportaRxPower outputs the following:
***** SNMP QUERY STARTED *****
1: ms430580mMesrportaRxPower (integer) 10
***** SNMP QUERY FINISHED *****
The value returned from the SFP in Line 1 is: 10.
So applying the formula: Rx_Pwr(mW) = 10/10000
Gives an actual value of: 0.001mW
And applying the formula: Rx_Pwr(dBm) = 10xlog(10/10000)
Gives an actual value of: -30dBm
Appendixes
Laser Class
Laser Class
Risks
General Requirements
1
Considered safe to eye and Skin under
Protective housing: may be
all reasonably foreseeable conditions
required.
of operation.
MS430580M Leds description
LED
Status
Condition
SW
Green On
Normal
Red On
Init/ReBoot
Green On
Normal
Red On
Init./Reboot
Green
Normal
Red
Line 1 Loss of Signal
Green
Normal
Red
Line 1 Failure
Green
Normal
Red
Line 2 Loss of Signal
Green
Normal
Red
Line 2 Failure
HW
Line 1 Los
Line 1 Fail
Line 2 Los
Line 2 fail
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 22/29
MS430580M MIB description
OID
Name
Access Description
1.3.6.1.4.1.20044.21.2
ms430580malarms
1.3.6.1.4.1.20044.21.2.1
ms430580mAlmOther
1.3.6.1.4.1.20044.21.2.1.1
ms430580mAlmOtherNurg
1.3.6.1.4.1.20044.21.2.1.2
ms430580mAlmOtherUrg
1.3.6.1.4.1.20044.21.2.1.3
ms430580mAlmOtherCrit
1.3.6.1.4.1.20044.21.2.1.3.0
ms430580mAlmsynthAlm0
1.3.6.1.4.1.20044.21.2.1.3.0.9
ms430580mAlmModuleGlobFailure
r
Module Failure: This OID is set on
detection of a failure originating from the
MS module
1.3.6.1.4.1.20044.21.2.1.3.0.14
ms430580mAlmSynUnlock
r
Synthesizer not locked: This OID indicates
that the frequency synthesizer is not
locked.
1.3.6.1.4.1.20044.21.2.1.3.0.15
ms430580mAlmDefFuseA
r
Fuse A fail: This OID indicates that the fuse
of the power input A is in fail condition
1.3.6.1.4.1.20044.21.2.1.3.0.16
ms430580mAlmDefFuseB
r
Fuse B Fail: This OID indicates that the fuse
ofthe power input B is in fail condition
1.3.6.1.4.1.20044.21.2.2
ms430580mAlmClient
1.3.6.1.4.1.20044.21.2.2.1
ms430580mAlmClientNurg
1.3.6.1.4.1.20044.21.2.2.1.20
ms430580mAlmline1TrscvWarnDdm
1.3.6.1.4.1.20044.21.2.2.1.20.1
ms430580mAlmLine1TxPwLowWng
r
TRSCV 1 Tx Power Low warning: Warning
indicating that the transceiver output
power of Line 1 is lower than the
threshold value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.2.1.20.2
ms430580mAlmLine1TxPwrHighWng
r
TRSCV 1 Tx Power High warning: Warning
indicating that the transceiver output
power of Line 1 is higher than the
threshold value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.2.1.20.3
ms430580mAlmLine1TxBiasLowWng
r
TRSCV 1 Bias Low warning: Warning
indicating that the transceiver laser bias
current of Line 1 is lower than the
threshold value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.2.1.20.4
ms430580mAlmLine1TxBiasHighWng
r
TRSCV 1 Bias High warning: Warning
indicating that the transceiver laser bias
current of Line 1 is higher than the
threshold value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.2.1.20.7
ms430580mAlmLine1TempLowWng
r
TRSCV 1 Temp Low warning:Warning
indicating that the transceiver
temperature of Line 1 is lower than the
threshold value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.2.1.20.8
ms430580mAlmLine1TempHighWng
r
TRSCV 1 Temp High warning: Warning
indicating that the transceiver
temperature of Line 1 is higher than the
threshold value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.2.1.20.15
ms430580mAlmLine1RxPwrLowWng
r
TRSCV 1 Rx Power Low warning: Warning
indicating that the transceiver input power
of Line 1 is lower than the threshold value
written in the transceiver EEPROM
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 23/29
OID
Name
Access Description
1.3.6.1.4.1.20044.21.2.2.3.8.1
ms430580mAlmLine1TrscvAbsent
r
Line 1 SFP not plugged :This OID
indicates that the transceiver module 2 is
not present.
1.3.6.1.4.1.20044.21.2.2.3.8.2
ms430580mAlmLine1TrscvDdmAbsent
r
DDM supported on Line 1 SFP :This OID
indicates that the transceiver module 1
does not support Digital Diagnostic
Monitoring Functions
1.3.6.1.4.1.20044.21.2.2.3.8.4
ms430580mAlmLine1HwFail
r
Line 1 HW Failure :This OID indicates a
hardware failure on the Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.5
ms430580mAlmLine1TrscvLsd
r
Line 1 SFP optical TX ON :This OID
indicates the optical output power is off
on Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.9
ms430580mAlmLine1TrscvDdmWarning
r
Warning DDM on Optical Module 1: This
OID indicates a warning is present
coming out of optical interface DDM on
Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.10
ms430580mAlmLine1TrscvDdmAlm
r
Alarm DDM on Optical Module 1: This
OID indicates an alarm is present coming
out of optical interface DDM on Line 1
1.3.6.1.4.1.20044.21.2.2.3.8.12
ms430580mAlmLine1Fail
r
Line 1 Failure: This OID indicates a
failure on the Line 1
1.3.6.1.4.1.20044.21.2.2.3.16
ms430580mAlmline1AccessioAlm
1.3.6.1.4.1.20044.21.2.2.3.16.1
ms430580mAlmLine1LasFail
r
Line 1 SFP Tx Failed: This OID indicates
that the transmitter fails for the
transceiver plugged into the Line 1 (this
alarm reports the transmitter failure
alarm generated by the transceivers)
1.3.6.1.4.1.20044.21.2.2.3.16.4
ms430580mAlmLine1Los
r
Loss of Optical signal on Line 1: This OID
indicates that no signal is present on the
transceiver 1
1.3.6.1.4.1.20044.21.2.3
ms430580mAlmLine
1.3.6.1.4.1.20044.21.2.3.1
ms430580mAlmLineNurg
1.3.6.1.4.1.20044.21.2.3.1.28
ms430580mAlmline2TrscvWarnDdm
1.3.6.1.4.1.20044.21.2.3.1.28.1
ms430580mAlmLine2TxPwLowWng
r
TRSCV 2 Tx Power Low warning:
Warning indicating that the transceiver
output power of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.2
ms430580mAlmLine2TxPwrHighWng
r
TRSCV 2 Tx Power High warning:
Warning indicating that the transceiver
output power of Line 2 is higher than
the threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.3
ms430580mAlmLine2TxBiasLowWng
r
TRSCV 2 Bias Low warning: Warning
indicating that the transceiver laser bias
current of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.4
ms430580mAlmLine2TxBiasHighWng
r
TRSCV 2 Bias High warning :Warning
indicating that the transceiver laser bias
current of Line 2 is higher than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.7
ms430580mAlmLine2TempLowWng
r
TRSCV 2 Temp Low warning:Warning
indicating that the transceiver
temperature of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 24/29
OID
Name
Access
Description
1.3.6.1.4.1.20044.21.2.3.1.28.8
ms430580mAlmLine2TempHighWng
r
TRSCV 2 Temp High warning:
Warning indicating that the
transceiver temperature of Line 2 is
higher than the threshold value
written in the transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.15
ms430580mAlmLine2RxPwrLowWng
r
TRSCV 2 Rx Power Low warning:
Warning indicating that the
transceiver input power of Line 2 is
lower than the threshold value
written in the transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.28.16
ms430580mAlmLine2RxPwrHighWng
r
TRSCV 2 Rx Power High warning:
Warning indicating that the
transceiver input power of Line 2 is
higher than the threshold value
written in the transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.1.31
ms430580mAlmline2CdrAlm
1.3.6.1.4.1.20044.21.2.3.1.31.1
ms430580mAlmLine2CdrLossofsignal
r
Line 2 CDR Loss of Signal :This OID
indicates that a Loss of electrical
signal is detected on the Line 2 CDR
1.3.6.1.4.1.20044.21.2.3.1.31.2
ms430580mAlmLine2CdrLossoflock
r
Line 2 CDR Loss of Lock :This OID
indicates that the Line 2 CDR is not
locked
1.3.6.1.4.1.20044.21.2.3.1.31.3
ms430580mAlmLine2CdrRefAbsent
r
Line 2 CDR Reference clock absent:
This OID indicates that the CDR
reference clock is absent on Line 2
1.3.6.1.4.1.20044.21.2.3.2
ms430580mAlmLineUrg
1.3.6.1.4.1.20044.21.2.3.2.26
ms430580mAlmline2TrscvAlmDdm
1.3.6.1.4.1.20044.21.2.3.2.26.1
ms430580mAlmLine2TxPwrLowAla
r
TRSCV 2 Tx Power Low: Alarm
indicating that the transceiver
output power of Line 2 is lower than
the threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.2
ms430580mAlmLine2TxPwrHighAla
r
TRSCV 2 Tx Power High: Alarm
indicating that the transceiver
output power of Line 2 is higher
than the threshold value written in
the transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.3
ms430580mAlmLine2TxBiasLowAla
r
TRSCV 2 Bias Low: Alarm indicating
that the transceiver laser bias current
of Line 2 is lower than the threshold
value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.4
ms430580mAlmLine2TxBiasHighAla
r
TRSCV 2 Bias High: Alarm indicating
that the transceiver laser bias current
of Line 2 is higher than the threshold
value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.7
ms430580mAlmLine2TempLowAla
r
TRSCV 2 Temp Low: Alarm indicating
that the transceiver temperature of
Line 2 is lower than the threshold
value written in the transceiver
EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.8
ms430580mAlmLine2TempHighAla
r
TRSCV 2 Temp High: Alarm
indicating that the transceiver
temperature of Line 2 is higher than
the threshold value written in the
transceiver EEPROM
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 25/29
OID
Name
Access Description
1.3.6.1.4.1.20044.21.2.3.2.26.15
ms430580mAlmLine2RxPwrLowAla
r
TRSCV 2 Rx Power Low: Alarm
indicating that the transceiver input
power of Line 2 is lower than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.2.26.16
ms430580mAlmLine2RxPwrHighAla
r
TRSCV 2 Rx Power High: Alarm
indicating that the transceiver input
power of Line 2 is higher than the
threshold value written in the
transceiver EEPROM
1.3.6.1.4.1.20044.21.2.3.3
ms430580mAlmLineCrit
1.3.6.1.4.1.20044.21.2.3.3.7
ms430580mAlmsynthAlm7
1.3.6.1.4.1.20044.21.2.3.3.7.1
ms430580mAlmLine2TrscvAbsent
r
Line 2 SFP not plugged: This OID
indicates that the transceiver
module 2 is not present.
1.3.6.1.4.1.20044.21.2.3.3.7.2
ms430580mAlmLine2TrscvDdmAbsent
r
DDM supported on Line 2 SFP: This
OID indicates that the transceiver
module 2 does not support Digital
Diagnostic Monitoring Functions
1.3.6.1.4.1.20044.21.2.3.3.7.4
ms430580mAlmLine2HwFail
r
Line 2 HW Failure: This OID indicates
a hardware failure on the Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.5
ms430580mAlmLine2TrscvLsd
r
Line 2 SFP optical TX ON :This OID
indicates the optical output power
is off on Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.9
ms430580mAlmLine2TrscvDdmWarning
r
Warning DDM on Optical Module 2:
This OID indicates a warning is
present coming out of optical
interface DDM on Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.10
ms430580mAlmLine2TrscvDdmAlm
r
Alarm DDM on Optical Module 2:
This OID indicates an alarm is
present coming out of optical
interface DDM on Line 2
1.3.6.1.4.1.20044.21.2.3.3.7.12
ms430580mAlmLine2Fail
r
Line 2 Failure: This OID indicates a
failure on the Line 2
1.3.6.1.4.1.20044.21.2.3.3.24
ms430580mAlmline2AccessioAlm
1.3.6.1.4.1.20044.21.2.3.3.24.1
ms430580mAlmLine2LasFail
r
Line 2 SFP Tx Failed :This OID
indicates that the transmitter fails
for the transceiver plugged into the
Line 1 (this alarm reports the
transmitter failure alarm generated
by the transceivers)
1.3.6.1.4.1.20044.21.2.3.3.24.4
ms430580mAlmLine2Los
r
Loss of Optical signal on Line 2 :This
OID indicates that no signal is
present on the transceiver 2
1.3.6.1.4.1.20044.21.3
ms430580mmeasures
1.3.6.1.4.1.20044.21.3.1
ms430580mMesrOther
1.3.6.1.4.1.20044.21.3.2
ms430580mMesrClient
1.3.6.1.4.1.20044.21.3.2.16
ms430580mMesrline1Temperature
r
Line 1 SFP Temperature :This OID
gives the temperature of the
transceiver Line 1, read from the
DDM (Digital Diagnostic
Monitoring) (Unit = °C)
1.3.6.1.4.1.20044.21.3.2.17
ms430580mMesrline1Volt
r
Line 1 SFP Power Supply: This OID
gives the voltage of the transceiver
Line 1, read from the DDM (Digital
Diagnostic Monitoring) (Unit = V)
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 26/29
OID
Name
Access Description
1.3.6.1.4.1.20044.21.3.2.18
ms430580mMesrline1TxBias
r
Line 1 SFP Laser bias: This OID gives
the bias value of the transceiver Line
1, read from the
DDM (Digital Diagnostic Monitoring)
(Unit = mA)
1.3.6.1.4.1.20044.21.3.2.19
ms430580mMesrline1TxPower
r
Line 1 SFP Transmitted Power: This
OID gives the transmit power value of
the transceiver Line 1, read from the
DDM (Digital Diagnostic Monitoring)
(Unit = dBm)
1.3.6.1.4.1.20044.21.3.2.20
ms430580mMesrline1RxPower
r
Line 1 SFP Received Power: This OID
gives the receive power value of the
transceiver Line 1, read from the DDM
(Digital Diagnostic Monitoring) (Unit
= dBm)
1.3.6.1.4.1.20044.21.3.3
ms430580mMesrLine
1.3.6.1.4.1.20044.21.3.3.24
ms430580mMesrline2Temperature
r
Line 2 SFP Temperature :This OID
gives the temperature of the
transceiver Line 2, read from the DDM
(Digital Diagnostic Monitoring) (Unit
= °C)
1.3.6.1.4.1.20044.21.3.3.25
ms430580mMesrline2Volt
r
Line 2 SFP Power Supply: This OID
gives the voltage of the transceiver
Line 2, read from the DDM (Digital
Diagnostic Monitoring) (Unit = V)
1.3.6.1.4.1.20044.21.3.3.26
ms430580mMesrline2TxBias
r
Line 2 SFP Laser bias: This OID gives
the bias value of the transceiver Line
2, read from the DDM (Digital
Diagnostic Monitoring) (Unit = mA)
1.3.6.1.4.1.20044.21.3.3.27
ms430580mMesrline2TxPower
r
Line 2 SFP Transmitted Power :This
OID gives the transmit power value of
the transceiver Line 2, read from the
DDM (Digital Diagnostic Monitoring)
(Unit = dBm)
1.3.6.1.4.1.20044.21.3.3.28
ms430580mMesrline2RxPower
r
Line 2 SFP Received Power: This OID
gives the receive power value of the
transceiver Line 2, read from the DDM
(Digital Diagnostic Monitoring) (Unit
= dBm)
1.3.6.1.4.1.20044.21.6
ms430580mcontrolsWrite
1.3.6.1.4.1.20044.21.6.1
ms430580mCtrlOther
1.3.6.1.4.1.20044.21.6.1.0
ms430580mCtrlsynth0
1.3.6.1.4.1.20044.21.6.1.0.1
ms430580mCtrlConfLoad
r/w
Load Configuration Tables: When set
this enables loading from flash
configuration1 into the module.
1.3.6.1.4.1.20044.21.6.1.0.9
ms430580mCtrlConfFlash
r/w
Write Configuration Tables: This bit
saves the current configuration of the
module as configuration in the flash.
1.3.6.1.4.1.20044.21.6.1.0.13
ms430580mCtrlConfClear
r/w
Clear Configuration Tables :This bit
clears the configuration tables from
configuration in the flash.
1.3.6.1.4.1.20044.21.6.1.4
ms430580mCtrlsynth4
1.3.6.1.4.1.20044.21.6.1.4.1
ms430580mCtrlCorrelatOn
r/w
Enable Alarm Correlation: This OID
enables the alarm correlation in the
MS module.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 27/29
OID
Name
Access Description
1.3.6.1.4.1.20044.21.6.1.4.2
ms430580mCtrlCorrelatOff
r/w
Disable Alarm Correlation :This OID
disables the alarm correlation in the
MS module.
1.3.6.1.4.1.20044.21.6.1.5
ms430580mCtrlswMgnt
1.3.6.1.4.1.20044.21.6.1.5.2
ms430580mCtrlColdReset
r/w
MS module Cold Reset: This OID,
when set, causes a cold reset of the
Software. This reset is traffic
affecting, and the configuration of
Software is reloaded on start-up.
1.3.6.1.4.1.20044.21.6.1.5.3
ms430580mCtrlWarmReset
r/w
MS module Warm Reset: This OID,
when set, causes a warm reset of the
Software. This reset is not traffic
affecting, and the configuration of
the Sofwtare remains unchanged.
1.3.6.1.4.1.20044.21.6.1.64
ms430580mCtrlledTest
1.3.6.1.4.1.20044.21.6.1.64.1
ms430580mCtrlGreenLed
r/w
Green Leds Test :This OID switches
on all the green Leds as a test
feature.
1.3.6.1.4.1.20044.21.6.1.64.2
ms430580mCtrlRedLed
r/w
Red Leds Test :This OID switches on
all the red Leds as a test feature.
1.3.6.1.4.1.20044.21.6.1.64.3
ms430580mCtrlLedOff
r/w
Leds Off: This OID switches off all
the Leds as a test feature.
1.3.6.1.4.1.20044.21.6.2
ms430580mCtrlClient
1.3.6.1.4.1.20044.21.6.2.16
ms430580mCtrlline1TrscvOnoff
1.3.6.1.4.1.20044.21.6.2.16.1
ms430580mCtrlLine1TrscvOnoff
r/w
Line 1 SFP Optical Laser OFF: This
OID switches off the transceiver on
Line 1
1.3.6.1.4.1.20044.21.6.3
ms430580mCtrlLine
1.3.6.1.4.1.20044.21.6.3.24
ms430580mCtrlline2TrscvOnoff
1.3.6.1.4.1.20044.21.6.3.24.1
ms430580mCtrlLine2TrscvOnoff
r/w
Line 2 SFP Optical Laser OFF: This
OID switches off the transceiver on
Line 2
1.3.6.1.4.1.20044.21.7
ms430580mri
1.3.6.1.4.1.20044.21.7.2
ms430580mRinvReloadInventory
r/w
Reload the inventory: This OID
triggers an inventory reload.
1.3.6.1.4.1.20044.21.7.4
ms430580mRinvHwPlatform
r
Module platform description: This
OID contains the description of the
Module.
1.3.6.1.4.1.20044.21.7.5
ms430580mRinvSwPlatform
r
SW platform description: This OID
contains the description of the
Software platform.
1.3.6.1.4.1.20044.21.7.6
ms430580mRinvLine1SFP
r
Inventory for the SFP: This OID
contains the inventory for the Line 1
SFP
1.3.6.1.4.1.20044.21.7.7
ms430580mRinvLine2SFP
r
Inventory for the SFP: This OID
contains the inventory for the Line 2
SFP
1.3.6.1.4.1.20044.21.9
ms430580mConfig
1.3.6.1.4.1.20044.21.9.1
ms430580mCfgLsd
1.3.6.1.4.1.20044.21.9.1.1
ms430580mtableclientLsd
1.3.6.1.4.1.20044.21.9.2
ms430580mCfgStartUp
1.3.6.1.4.1.20044.21.9.2.1
ms430580mtableclientStartup
1.3.6.1.4.1.20044.21.9.2.1.2
ms430580mCfgline1TrscvCtrl
r/w
Default Settings on Line 1 : This
register configures the default
initialisation settings on Line 1.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
OID
Name
1.3.6.1.4.1.20044.21.9.2.2
ms430580mtablelineStartup
1.3.6.1.4.1.20044.21.9.2.2.2
ms430580mCfgline2TrscvCtrl
page 28/29
Access Description
r/w
Default Settings on Line 2: This
register configures the default
initialisation settings on Line 2.
1.3.6.1.4.1.20044.21.9.2.2.18 ms430580mCfgbitrateSelect
r/w
Bitrate selection on Line 1/2: This
OID register configure the bitrate
for the client and lineinterface
(0=STS48 : 2,4 to 2,7 Gb/s - 1=1GBE
: 1,2 to 1,35 Gb/s - 2=STS12 : 600 to
675 Mb/s - 3=STS3 : 150 to 168 Mb/s
- 4=2GFC : 2 to 2,4 Gb/s - 5=1GFC :
1,0 to 1,2 Gb/s - 6=500 to 600 Mb/s 7=Fast Ethernet : 125 to 150 Mb/s 8=STS48 + FEC : 2,4-2,7 Gb/s 9=STS12 + FEC : 600-675 Mb/s 10=STS3 + FEC : 150- 168 Mb/s ).
1.3.6.1.4.1.20044.21.9.257
ms430580mCfgWriteConfiguration
r/w
Write configuration to module: This
OID writes the complete
configuration to the module
1.3.6.1.4.1.20044.21.10
ms430580mtraps
1.3.6.1.4.1.20044.21.10.4
ms430580mtrapBoardNumber
r
Last module which generates a trap
1.3.6.1.4.1.20044.21.10.30
ms430580mLine1TrapNotUrgentGoesOn
n/a
Not urgent Line 1 default is
activated
1.3.6.1.4.1.20044.21.10.31
ms430580mLine1TrapNotUrgentGoesOff
n/a
Not urgent Line 1 default
disappeared
1.3.6.1.4.1.20044.21.10.32
ms430580mLine1TrapUrgentGoesOn
n/a
Urgent Line 1 default is activated
1.3.6.1.4.1.20044.21.10.33
ms430580mLine1TrapUrgentGoesOff
n/a
Urgent Line 1 default disappeared
1.3.6.1.4.1.20044.21.10.34
ms430580mLine1TrapCritGoesOn
n/a
Critical Line 1 default is activated
1.3.6.1.4.1.20044.21.10.35
ms430580mLine1TrapCritGoesOff
n/a
Critical Line 1 default disappeared
1.3.6.1.4.1.20044.21.10.40
ms430580mLine2NotUrgentGoesOn
n/a
Not urgent Line 2 default is
activated
1.3.6.1.4.1.20044.21.10.41
ms430580mLine2NotUrgentGoesOff
n/a
Not urgent Line 2 default
disappeared
1.3.6.1.4.1.20044.21.10.42
ms430580mLine2UrgentGoesOn
n/a
Urgent Line 2 default is activated
1.3.6.1.4.1.20044.21.10.43
ms430580mLine2UrgentGoesOff
n/a
Urgent Line 2 default disappeared
1.3.6.1.4.1.20044.21.10.44
ms430580mLine2CritGoesOn
n/a
Critical Line 2 default is activated
1.3.6.1.4.1.20044.21.10.45
ms430580mLine2CritGoesOff
n/a
Critical Line 2 default disappeared
1.3.6.1.4.1.20044.21.10.50
ms430580mPowerTrapUrgentGoesOn
n/a
Urgent power supply default is
activated
1.3.6.1.4.1.20044.21.10.51
ms430580mPowerTrapUrgentGoesOff
n/a
Urgent power supply default
disappeared
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater
page 29/29
Front Panel Layout
The MS430580M occupies one slot in the MICROSENS chassis. Line and Client interfaces
are SFP cages capable of hosting standard SFP modules.
Figure 1: MS430580M front panel layout.
Technical Specifications
Type
Media Converter/Signal Repeater
Connectors
SFP ports
Data rate
from 125 Mbps up to 2.67 Gbps
LED displays
SW
HW
Los
Fail
Power consumption
8 W typical
Software loading
Hardware ready
Signal lost
Transmission failure
10 W max
Operating temperature 0°C to 50°C
Storage temperature
-20°C to 85°C
Order Information
Art. No.
MS430580M
Description
3R Retimer Module (FE, 1GbE, 1GFC, 2GFC, 155Mb/s,
622Mb/s, 2,5Gb/s) Port 1&2: SFP Slots (not included)
Connectors
SFP
MICROSENS reserves the right to make any changes without further notice to any product to improve reliability,
function or design. MICROSENS does not assume any liability arising out of the application or use of any product.
tk/1207
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com