Thru-the-wall AIR CONDITIONERS

Thru-the-wall AIR CONDITIONERS
2009
cool only | heat pumps | electric heat
THRU-THE-WALL
27” sleeve
Friedrich thru-the-wall
air conditioners are ideal
for new construction,
retrofits and remodels
8,000 to 15,800 BTU/h COOLING l 8,100 to 11,000 BTU/h HEATING
EERs up to 10.5
cool only / heat pumps / cool w/electric heat
• High efficiency operation
saves on energy costs
• Ideal for thicker wall installations, where side fins don’t fit
• Residential/commercial
applications
• Easy-to-reach, top mount
controls
• Mounts flush with the exterior
wall for a neat appearance
• Three-speed fan
• A high efficiency replacement for 27" sleeves including Fedders A and B*. Sleeve
measures 27" W x 16 3/4" H
• Easy-to-clean filter
The Most Energy Efficient
Solid-side Air Conditioner
Chassis installs into
existing 27” sleeves
• Efficient rotary compressor
• Auto restart
DIGITAL CONTROLS feature
• Fully functional remote control
• 24 hour programmable timer
• Money Saver® setting saves energy by
cycling the fan with the compressor
• Smart Fan auto-adjusts fan speed to
maintain desired temperature
• Auto-memory backup saves setting
should power be interrupted
REMOTE
CONTROL
24-HOUR
TIMER
MONEY SAVER
FEATURE
SMART
FAN
ANTIMICROBIAL
FILTER
Friedrich
WSC Sleeve
Fedders
A Sleeve
Fedders
B Sleeve*
Height (inches)
16 3/4
16 3/4
16 3/4
Width (inches)
27
27
27
Depth (inches)
16 3/4
16 3/4
19 3/4
Sleeve Dimensions
5
Energy Star®
models
Units are shown installed in WSC sleeve (sold and shipped separately)
*Installation in Fedders B sleeve requires a baffle kit. See BAK accessory under accessories.
THRU-THE-WALL
26” sleeve l universal fit
THRU-THE-WALL units mount
flush with exterior walls for a sleek
appearance, as well as unobstructed
window views.
(Wallmaster WSC sleeve shown with
architectural grille. Uni-fit grille has
different appearance.)
8,000 to 13,000 BTU/h COOLING l 3,850 to 11,200 BTU/h HEATING
EERs up to 9.6
Universal Fit for Easy
Replacement
Chassis installs into
existing 26" sleeves
cool only, cool w/electric heat
• Rotary compressors
provide quiet, dependable
performance
• Six-way air flow control
• Auto restart
• Washable/reusable filter
• Seacoast protection
• Stale air exhaust
HEAT/COOL MODELS feature mechanical controls,
two cooling speeds, two heating speeds, plus
one fan-only setting.
COOLING MODELS feature electronic controls
with remote control, Money Saver® setting that
saves energy by cycling the fan with the compressor and three cooling/three fan-only speeds.
dIGITAL CONTROLS feature (cool only models)
• 12 hour programmable timer
• Money Saver® setting saves energy by
cycling the fan with the compressor
REMOTE
CONTROL
12-HOUR
TIMER
MONEY SAVER
FEATURE
Sleeve Dimensions
Height (inches)
5
Energy Star®
models
Friedrich
USC
Sleeve
Amana
Carrier
(51S
Series)
15 17/32
15 5/8
16 7/8
Fedders/
Emerson/
Friedrich
WSC
Emerson/
Fedders
GE/
Hotpoint
Whirlpool
WhiteWestinghouse/
Frigidaire/
Carrier (52F
Series)
16 3/4
15 3/4
15 5/8
16 1/2
15 1/4
Width (inches)
25 7/8
26
25 3/4
27
26 3/4
26
25 7/8
25 1/2
Depth (inches)
16 23/32
16 7/8
18 5/8
16 3/4 or
19 3/4
15
16 7/8
17 1/8
or 23
16, 17 1/2
or 22
Units are shown without USC sleeve (USC sleeves sold and shipped separately)
27” Sleeve Exterior Grilles
CORRECT Vertical Louvers
IMPORTANT:
Operating the air
conditioner with incorrect
rear grille or without Baffle
Adapter Kit (on 19 3/4”
deep sleeve) will recirculate
discharge air and cause
compressor overload to trip.
INCORRECT Horizontal Louvers
WSC Sleeve
Optional Architectural Grille- AG
WSC Sleeve
Standard Grille - Ships
with sleeve
Installation Accessories (27” sleeve models only)
DK / Drain Kit
SB / Sub Base
Installed at the back of the unit and allows
for attachment to permanent condensate
disposal system, if disposal is necessary
or desired.
IDK / Internal Drain Kit
Used as a base for the unit when
it is desired to place the cord and
receptacle within the installation, or
simply as a base for the unit when
mounted low in the wall.
New construction applications where
a condensate drain system has been
built into the wall interior.
BAK / Baffle Adapter Kit
Necessary when installing in a sleeve
deeper than 16 3/4" deep, such as
Fedders B sleeve (19 3/4" deep).
16 3/4"
Fedders B
19 3/4”
26” Sleeve Exterior Grilles
STANDARD GRILLE – Ships with USC sleeve
Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis
High-tech plastic for use on existing sleeves without any grille.
IMPORTANT:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine
whether or not the grille needs to be replaced and/or a baffle
adapter should be used.
USC Sleeve
Standard Grille
Sleeve shown with
Replacement Grille
Sleeve/Chassis Dimensions
Width
Depth
16 3/4"
15 3/4"
27"
26 1/2"
16 3/4"
21"
23"
22”
7 1/2"
–
9/16"
–
17 1/4"
–
27 1/4"
–
15 5/16"
–
USC Sleeve
US Chassis
15 1/2"
14 3/8"
25 7/8"
24"
16 3/4"
20 1/2"
20 1/8"
–
3 3/4"
1/2"
–
15 3/4"
–
26 1/8"
–
16 1/4"
–
UE Chassis
14 3/8"
24 5/8"
19 5/8"
3 1/2"
–
–
–
–
Model
Height
Minimum
Extension
Into Room
Minimum
Extension
Outside
Thru-the-wall
Finished Hole
Height Width Max. Depth
Depth
with
Front
WALLMASTER
WSC Sleeve
Chassis
UNI-FIT
US= 3 3/8”, UE= 2 7/8”
IMPORTANT:
US chassis w/front fully installed into USC sleeve
extends into room 3 3/8”. UE chassis w/front fully
installed into USC sleeve extends into room 2 7/8”.
IMPORTANT: Sleeves are sold and shipped separately to accommodate new construction and replacement requirements
DIGITAL CONTROLS with REMOTE
Commercial
& Residential
Applications
When should you
install a solid side
sleeve?
SOLID SIDE wall sleeve
allows for installation in
thick exterior walls where
the installation of room air
units with side vents would
effect performance and may
even void the warranty.
ROOM AIR CONDITIONER
Blocked side vents restrict air flow
FRIEDRICH THRU-THE-WALL
Solid-side sleeve (no side vents) can
be installed flush with exterior wall.
Specifications
Cooling
Capacity
BTU/h
 Energy Star® models
Heating
Watts
Energy
Efficiency
Ratio
EER
Moisture
Removal
Pints/Hr.
—
—
—
—
—
—
16.0/14.7
16.0/14.7
16.0/14.7
3.9/4.0
5.4/5.7
—
—
—
—
—
—
3550/2950
3550/2950
3550/2950
857/821
1182/1136
10.5
10.5
9.5
10.0/10.0
8.9/8.7
9.0/8.8
10.0/10.0
8.9/8.7
9.0/8.8
10.0/10.0
9.0/9.0
1.3
2.4
3.3
2.1
3.3
4.2
2.1
3.3
4.2
2.5
3.2
245
245
295
260
280
290
260
280
290
230
280
WSC
WSC
WSC
WSC
WSC
WSC
WSC
WSC
WSC
WSC
WSC
97/93
107/103
116/112
105/101
113/109
123/119
107/103
115/111
125/121
111/107
120/116
830
1040
1060/1040
1220
1220/1190
1530/1480
830
1060/1040
—
—
—
—
—
—
10.7
15.3/14.0
—
—
—
—
—
—
1230
3500/2900
9.6
9.4
9.4
9.4
9.4
8.5
9.6
9.4
2.2
3.2
3.2
3.8
3.8
4.0
2.2
3.2
260
270
285
290
290
300
260
285
USC
USC
USC
USC
USC
USC
USC
USC
77/73
82/78
82/78
84/80
84/80
88/84
77/73
82/78
1220/1190
15.3/14.0
3500/2900
9.4
3.8
290
USC
84/80
Heating
Capacity
BTU/h
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
8000
10000
13500
10000/10000
12500/12000
15800/15000
10000/10000
12500/12000
15800/15000
10100/9800
12500/12100
—
—
—
—
—
—
11000/9100
11000/9100
11000/9100
8100/7800
10400/10000
115
115
115
230/208
230/208
230/208
230/208
230/208
230/208
230/208
230/208
6.8
8.7
12.0
4.6/5.0
6.3/6.7
7.8/8.5
4.6/5.0
6.3/6.7
7.8/8.5
4.6/4.8
6.4/6.8
762
954
1415
1005/996
1404/1379
1756/1705
1005/996
1404/1379
1756/1705
1013/976
1389/1352
US08B10A
US10B10B
US10B30A
US12B10B
US12B30C
US14B30A
UE08A13B
UE10A33B
8000
9800
10000/9800
11500
11500/11200
13000/12600
8000
10000/9800
—
—
—
—
—
—
3850
11200/9200
115
115
230/208
115
230/208
230/208
115
230/208
7.5
9.6
4.7/5.2
11.2
5.6/6.0
7.0/7.5
7.5
4.7/5.2
UE12A33C
11500/11200
11200/9200
230/208
5.6/6.0
Model
Room
Weight
Side Air
Lbs.
Circulation Sleeve Ship/Net
WALLMASTER





WS08B10A
WS10B10A
WS14B10A
WS10B30A
WS13B30B
WS16B30A
WE10B33C
WE13B33C
WE16B33C
WY10B33C
WY13B33C
UNI-FIT





WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE
Change-over from heat pump operation to resistance operation on models
indicated is automatic at a preset outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops
and the electric heat starts, then operates with the fan to maintain indoor
comfort. Below 43°F, the unit remains in electric heat mode. During electric heat
mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7
amps, and 3550/2950 watts.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Plug Face/ Circuit Rating
Circuit Rating
Breaker
or T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
US08B10A, UE08A13B
US10B10B, US12B10B
125V - 15A
5 - 15P
6
WS10B30A, WS13B30B,
WS16B30A
US10B30A, US12B30C,
US14B30A
250V - 15A
6 - 15P
4
WE10B33C, WE13B33C, WE16B33C,
WY10B33C, WY13B33C
UE10A33B, UE12A33C
250V - 20A
6 - 20P
4
WallMaster
Uni-Fit
WS08B10A, WS10B10A,
WS14B10A
Model Number
Model Number
Wall
Outlet
Appearance
Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.
As an Energy Star® partner, Friedrich Air Conditioning Co. has determined that the selected
Energy Star® models ( ) meet the Energy Star® guidelines for energy efficiency.
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
TTW-09 (1-09)
Printed in USA