Chapter 2 Conducted Emission Test

Test Report --------------------------------------------------------------------------- 2/19
Contents
Chapter 1 Introduction
Description of EUT ................................................................................................................... 3
Configuration of Test Setup ...................................................................................................... 5
List of Support Equipment ........................................................................................................ 8
Chapter 2 Conducted Emission Test
Test Condition and Setup .......................................................................................................... 9
Conducted Test Placement ....................................................................................................... 10
Chapter 3 Radiated Emission Test
Test Condition and Setup ......................................................................................................... 11
Radiated Test Placement .......................................................................................................... 12
Appendix A :
Conducted test result ................................................................................................................ 13
Appendix B :
Radiated test result ................................................................................................................... 19
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 3/19
Chapter 1 Introduction
Description of EUT:
This EUT is a 12 Slot Universal Media Converter Rack, features as below:
ET-910MCR (12 Slot Universal Media Converter Rack):
Diagnostic LEDs:
Power A
Power B
Power: AC 100-240V, 50-60Hz
Consumption Power: Consumption power (Full Module)=59.90w
Consumption power (Empty Module)=10.89w
Dimensions:
Dimensions: 437 x 280 x 88 mm (W x D x H)
Weight: 5Kg
Temperature: Operating: 0~ 45℃
Storage: -20 ~ 60℃
Humidity: 5% ~ 90% RH
ET-912 (Fast Ethernet Switching Converter)
10/100Base-TX to 100Base-FX converter
Store & Forward switching mechanism
Comply to IEEE 802.3, 802.3u
MDI/MDIX Auto-Crossover supported
Auto-Negotiation or Manual mode setting of Speed & Duplex mode.
LED Indication: Power, FDX; TP 100, TP Link/Activity; FX 100, FX Link/Activity
Fiber Link Alarm function
ET-913 (Gigabit Ethernet Converter):
1000Base-T to 1000BASE-SX/LX Converter
Standard: IEEE 802.3z & 802.3ab
Interface: 1 * RJ-45 connector
1 * SC Duplex connector or
1 * SC Simplex connector (W2 type)
MDI/MDIX Auto-Crossover supported
LED: Power, FDX, TP Link, FO Link, TP ACT, FO ACT
Plug-and-Play installation
Support Link Alarm
Support Jumbo Frame (64-9216 Byte)
Support Voltage Monitor
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 4/19
Test method:
Pretest was found that the emission of operating mode is worse than standby mode. So, The
final test is made at the operating mode.
During testing, there are ten modes were tested:
ET-913 1000 x 1000Mbps + ET-912 100 x 100Mbps 110Vac/60Hz
ET-913 1000 x 1000Mbps 110Vac/60Hz
ET-912 100 x 100Mbps 110Vac/60Hz
ET-913 1000 x 1000Mbps + ET-912 100 x 100Mbps 230Vac/50Hz
ET-913 1000 x 1000Mbps 230Vac/50Hz
ET-912 100 x 100Mbps 230Vac/50Hz
The radiation pretest was found out the testing mode: “ET-913 1000 x 1000Mbps + ET-912
100 x 100Mbps 110Vac/60Hz” was the worst case.
During testing, the EUT was operated at “transmitting” and “receiving” mode
simultaneously.
The test placement as the photographs showed is the worst emission placed. (If the emission
is close to the ambient, the resolution BW and view resolution will be reduced and the data will
be recorded by detection of maximum hold peak mode.)
The testing configuration of test setup is showing in the next page.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 5/19
Configuration of test setup
Test Mode: ET-913 1000 x 1000Mbps +ET-912 100 x 100Mbps
Power
Source
ET-912
ET-912
ET-912
ET-912
Support
Equipment
To another PC
Located Remotely
Gigabit LAN Port
Support
Equipment
Dummy Load 200ohm
To another PC
Located Remotely
LAN Port
Connections:
EUT:
*Slot-1, 2 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-1, 2 (ET-913) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-3 (ET-913) UTP port --- via a 10m long, non-shielded, no ferrite bead, RJ-45
cable to the RJ-45 jack of the LAN card that installed in the PC located remotely.
*Slot-3 (ET-913) Fiber port --- via a 5m length fiber cable to the support equipment.
*Slot-4, 5 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-4, 5 (ET-913) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-6 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-6 (ET-913) Fiber port --- via a 1m length fiber cable to the fiber port of Slot-7.
*Slot-7 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-7 (ET-912) Fiber port --- via a 1m length fiber cable to the fiber port of Slot-6.
*Slot-8, 9 (CVT-100GW2) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-8, 9 (CVT-100GW2) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-10, 12 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-10, 12 (ET-912) Fiber port --- connect with each other.
*Slot-11 (ET-912) UTP port --- via a 10m long, non-shielded, no ferrite bead, RJ-45
cable to the RJ-45 jack of the LAN card that installed in the PC located remotely.
*Slot-11 (ET-912) Fiber port --- via a 5m length fiber cable to the support equipment.
*Power port --- via a 1.80m length power cable with a power adaptor to the power source.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 6/19
Configuration of test setup
Test Mode: ET-913 1000 x 1000Mbps
Power
Source
CVT-100GW2
CVT-100GW2
ET-912
ET-912
Support
Equipment
To another PC
Located Remotely
Gigabit LAN Port
Support
Equipment
Dummy Load 200ohm
Connections:
EUT:
*Slot-1, 2 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-1, 2 (ET-913) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-3 (ET-913) UTP port --- via a 10m long, non-shielded, no ferrite bead, RJ-45
cable to the RJ-45 jack of the LAN card that installed in the PC located remotely.
*Slot-3 (ET-913) Fiber port --- via a 5m length fiber cable to the support equipment.
*Slot-4, 5 (CVT-3002GW2) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-4, 5 (CVT-3002GW2) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-6 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-6 (ET-913) Fiber port --- via a 1m length fiber cable to the fiber port of Slot-7.
*Slot-7 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-7 (ET-912) Fiber port --- via a 1m length fiber cable to the fiber port of Slot-6.
*Slot-8, 9 (CVT-100GW2) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-8, 9 (CVT-100GW2) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-10, 12 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-10, 12 (ET-912) Fiber port --- connect with each other.
*Slot-11 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-11 (ET-912) Fiber port --- via a 5m length fiber cable to the support equipment.
*Power port --- via a 1.80m length power cable with a power adaptor to the power source.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 7/19
Configuration of test setup
Test Mode: ET-912 100 x 100Mbps
Power
Source
Fast Ethernet 2 Wave-Length
WDM Converter
Fast Ethernet 2 Wave-Length
WDM Converter
ET-912
ET-912
Support
Equipment
Support
Equipment
Dummy Load 200ohm
To another PC
Located Remotely
LAN Port
Connections:
EUT:
*Slot-1, 2 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-1, 2 (ET-913) Fiber port --- via a 1m length fiber cable connect with each other.
*Slot-3 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-3 (ET-913) Fiber port --- via a 5m length fiber cable to the support equipment.
*Slot-4, 5 (Fast Ethernet 2 Wave-Length WDM Converter) UTP port --- connect with a 2m length
RJ-45 cable that terminated with 200ohm.
*Slot-4, 5 (Gigabit Ethernet Converter) Fiber port --- via a 1m length fiber cable connect with each
other.
*Slot-6 (ET-913) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-6 (ET-913) Fiber port --- via a 1m length fiber cable to the fiber port of Slot-7.
*Slot-7 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-7 (ET-912) Fiber port --- via a 1m length fiber cable to the fiber port of Slot-6.
*Slot-8, 9 (Fast Ethernet 2 Wave-Length WDM Converter) UTP port --- connect with a 2m length
RJ-45 cable that terminated with 200ohm.
*Slot-8, 9 ((Fast Ethernet 2 Wave-Length WDM Converter)) Fiber port --- via a 1m length fiber
cable connect with each other.
*Slot-10, 12 (ET-912) UTP port --- connect with a 2m length RJ-45 cable that terminated
with 200ohm.
*Slot-10, 12 (ET-912) Fiber port --- connect with each other.
*Slot-11 (ET-912) UTP port --- via a 10m long, non-shielded, no ferrite bead, RJ-45
cable to the RJ-45 jack of the LAN card that installed in the PC located remotely.
*Slot-11 (ET-912) Fiber port --- via a 5m length fiber cable to the support equipment.
*Power port --- via a 1.80m length power cable with a power adaptor to the power source.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 8/19
List of support equipment
Conducted (Radiated) test:
PC
Model No.
Serial No.
FCC ID
Power type
Power cord
:
:
:
:
:
:
HP Brio 85xx 6/350
D6928A
SG91801432
Doc Approved
100 ~ 230VAC / 50 ~ 60Hz, 5A, Switching
Non-shielded, 2.33m long, Plastic, No ferrite core
PC
Model No.
Serial No.
FCC ID
Power type
Power cord
:
:
:
:
:
:
HP Vectra VE
D6970A
SG53000707
Doc Approved
100 ~ 230VAC / 50 ~ 60Hz, 5A, Switching
Non-shielded, 2.30m long, Plastic, No ferrite core
Giga Lan Card:
Model No.
:
Serial No.
:
FCC ID
:
Power Type :
Data Cable
:
LINKSYS
EG1064
N/A
Doc Approved
Powered by PC
UTP, 7', Plastic RJ-45 hoods, no ferrite bead
Lan Card
Model No.
Serial No.
FCC ID
Power Type
Data Cable
DELTA, SURTEC
AEF380-TX, SFC-7211R
N/A
Doc Approved
Powered by PC
UTP, 7', Plastic RJ-45 hoods, no ferrite bead
:
:
:
:
:
:
Support Equipment: Media Converter
Model No.
:
ET-912
Serial No.
:
N/A
FCC ID
:
Doc Approved
Power type
:
DC 5V 1.6A
Support Equipment: Media Converter
Model No.
:
ET-913
Serial No.
:
N/A
FCC ID
:
Doc Approved
Power type
:
DC 5V 1.6A
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 9/19
Chapter 2 Conducted emission test
Test condition and setup:
All the equipment is placed and setup according to the CISPR 22.
The EUT is assembled on a wooden table that is 80 cm high, is placed 40 cm from the back-wall
that is a vertical conducting plane. One LISN is for EUT, the other LISN is for support
equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch
box for selecting L1 or L2, then connect to a preamplifier and spectrum.
The spectrum measured from 150KHz to 30MHz. Conducted emission levels are detected
at max. peak mode. But if the max. peak mode failed or over average limit, it will be measured
by QP and average detection mode using the Receiver.
While testing, there is the worst-emission plot printed at peak detection mode, and there are
more than 6 highest emissions relative to limit recorded. The plot is kept as the original data, not
included in test report.
List of test Instrument :
Calibration Date
Instrument Name
Receiver
LISN (EUT)
LISN (Support E.)
Preamplifier
Line switch box
Model No.
SCR3102
3825/2
3825/2
EQ3-006
EQ3-007
Brand
SCHAFFNER
EMCO
EMCO
TRC
TRC
Serial No.
012
9411-2284
9210-2007
-----------------
Last time
03/29/03
06/17/03
05/31/03
05/15/03
05/15/03
Next time
03/28/04
06/16/04
05/31/04
05/15/04
05/15/04
The level of confidence of 95% , the uncertainty of measurement of conducted emission is ± 2.02 dB .
Test Result: Pass (Appendix A)
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 10/19
Conducted Test Placement: (Photographs)
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 11/19
Chapter 3 Radiated emission test
Test condition and setup:
Pretest : Prior to the final test (OATS test) ,the EUT is placed in a shielded enclosure, and
scan from 30MHz to 1GHz. This is done to ensure the radiation exactly emits form the EUT.
Final test: Final radiation measurement is made on a 10 - meter, open-field test site.
The EUT is placed on a nonconductive table that is 0.8m height, the top surface is 1.0 x 1.5
meter. The placement is according to CISPR 22.
The M. E. whole range Antenna is used to measure frequency from 30 MHz to 1GHz. The
final test is used the Receiver.
Measure more than six top marked frequencies generated form pretest by computer step by
step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from
1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and
vertical polarization.
Appropriated preamplifier that is made by TRC is used for improving sensitivity and
precaution is taken to avoid overloading. The spectrum analyzer’s 6dB bandwidth is set to 120
KHz, and the EUT is measured at quasi-peak mode.
If the emission is close to the frequency band of ambient, the tester will recheck the data
and the corrected data will be written in the test data sheet. If the emission is just within the
ambient, the data from shield room will be taken as the final data.
List of test Instrument :
Calibration Date
Instrument Name Model No.
Brand
Serial No.
Last time
Next time
Receiver
SCR3102
SCHAFFNER
021
03/29/03
03/28/04
Control Box
TWR95-4
TRC
CB-002
N/A
N/A
Antenna
CBL6141A SCHAFFNER
4188
11/29/02
11/29/03
Open test side (Antenna, Amplify, cable calibrated together)
05/16/03
05/15/04
The level of confidence of 95%, the uncertainty of measurement of radiated emission is ± 3.44 dB.
Test Result : Pass (Appendix B)
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 12/19
Radiated Test Placement: (Photographs)
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 13/19
Appendix A
Conducted Emission Test Result:
Test Mode: ET-912 100 x 100Mbps 110Vac/60Hz
Testing room :
Temperature : 23 ° C
Humidity : 63 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
153.00
43.75
***.**
***.**
65.91
55.91
-12.16
169.00
34.53
***.**
***.**
65.46
55.46
-20.93
203.00
42.04
***.**
***.**
64.49
54.49
-12.44
208.00
34.44
***.**
***.**
64.34
54.34
-19.90
1027.00
25.61
***.**
***.**
56.00
46.00
-20.39
1084.00
24.61
***.**
***.**
56.00
46.00
-21.39
6890.00
32.19
***.**
***.**
60.00
50.00
-17.81
22460.00
30.24
***.**
***.**
60.00
50.00
-19.76
23050.00
34.35
***.**
***.**
60.00
50.00
-15.65
24120.00
29.75
***.**
***.**
60.00
50.00
-20.27
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
152.00
48.87
***.**
***.**
65.94
55.94
-7.070
156.00
45.06
***.**
***.**
65.83
55.83
-10.77
163.00
40.78
***.**
***.**
65.63
55.63
-14.85
169.00
40.53
***.**
***.**
65.46
55.46
-14.93
183.00
33.74
***.**
***.**
65.06
55.06
-21.32
202.00
45.62
***.**
***.**
64.51
54.51
-8.89
272.00
31.31
***.**
***.**
62.51
52.51
-21.20
22310.00
31.12
***.**
***.**
60.00
50.00
-18.88
23050.00
37.67
***.**
***.**
60.00
50.00
-12.33
24120.00
30.84
***.**
***.**
60.00
50.00
-19.16
*The reading amplitudes are all under limit.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 14/19
Conducted Emission Test Result:
Test Mode: ET-912 100 x 100Mbps 230Vac/50Hz
Testing room :
Temperature : 23 ° C
Humidity : 63 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
150.00
42.90
***.**
***.**
66.00
56.00
-13.10
156.00
37.29
***.**
***.**
65.83
55.83
-18.54
201.00
42.60
***.**
***.**
64.54
54.54
-11.94
1048.00
26.42
***.**
***.**
56.00
46.00
-19.58
6890.00
33.61
***.**
***.**
60.00
50.00
-16.39
21560.00
27.63
***.**
***.**
60.00
50.00
-22.37
22460.00
30.22
***.**
***.**
60.00
50.00
-19.78
23050.00
35.06
***.**
***.**
60.00
50.00
-14.94
23650.00
33.80
***.**
***.**
60.00
50.00
-16.20
25870.00
28.94
***.**
***.**
60.00
50.00
-21.06
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
152.00
46.63
***.**
***.**
65.94
55.94
-9.31
163.00
41.12
***.**
***.**
65.63
55.63
-14.51
169.00
38.02
***.**
***.**
65.46
55.46
-17.44
173.00
37.43
***.**
***.**
65.34
55.34
-17.92
179.00
37.64
***.**
***.**
65.17
55.17
-17.53
201.00
46.75
***.**
***.**
64.54
54.54
-7.80
272.00
35.06
***.**
***.**
62.51
52.51
-17.45
22460.00
32.64
***.**
***.**
60.00
50.00
-17.36
23050.00
34.75
***.**
***.**
60.00
50.00
-15.25
23650.00
33.87
***.**
***.**
60.00
50.00
-16.13
*The reading amplitudes are all under limit.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 15/19
Conducted Emission Test Result:
Test Mode: ET-913 1000 x 1000Mbps 110Vac/60Hz
Testing room :
Temperature : 23 ° C
Humidity : 57 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
150.00
43.85
***.**
***.**
66.00
56.00
-12.15
155.00
40.54
***.**
***.**
65.86
55.86
-15.32
165.00
35.72
***.**
***.**
65.57
55.57
-19.85
202.00
42.65
***.**
***.**
64.51
54.51
-11.87
6890.00
28.76
***.**
***.**
60.00
50.00
-21.24
7070.00
27.45
***.**
***.**
60.00
50.00
-22.55
7820.00
27.40
***.**
***.**
60.00
50.00
-22.60
23050.00
30.12
***.**
***.**
60.00
50.00
-19.88
23650.00
35.01
***.**
***.**
60.00
50.00
-14.99
26220.00
28.48
***.**
***.**
60.00
50.00
-21.52
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
151.00
44.79
***.**
***.**
65.97
55.97
-11.18
155.00
43.31
***.**
***.**
65.86
55.86
-12.54
166.00
44.13
***.**
***.**
65.54
55.54
-11.42
175.00
37.06
***.**
***.**
65.29
55.29
-18.22
179.00
34.99
***.**
***.**
65.17
55.17
-20.18
191.00
39.38
***.**
***.**
64.83
54.83
-15.45
201.00
48.10
***.**
***.**
64.54
54.54
-6.45
7880.00
29.17
***.**
***.**
60.00
50.00
-20.83
21860.00
29.54
***.**
***.**
60.00
50.00
-20.46
23050.00
33.23
***.**
***.**
60.00
50.00
-16.77
*The reading amplitudes are all under limit.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 16/19
Conducted Emission Test Result:
Test Mode: ET-913 1000 x 1000Mbps 230Vac/50Hz
Testing room :
Temperature : 23 ° C
Humidity : 57 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
150.00
45.77
***.**
***.**
66.00
56.00
-10.23
162.00
38.15
***.**
***.**
65.66
55.66
-17.51
167.00
35.98
***.**
***.**
65.51
55.51
-19.53
197.00
36.85
***.**
***.**
64.66
54.66
-17.81
202.00
43.88
***.**
***.**
64.51
54.51
-10.64
208.00
37.05
***.**
***.**
64.34
54.34
-17.29
1015.00
27.63
***.**
***.**
56.00
46.00
-18.37
1063.00
29.15
***.**
***.**
56.00
46.00
-16.85
23050.00
30.79
***.**
***.**
60.00
50.00
-19.21
24120.00
29.06
***.**
***.**
60.00
50.00
-20.94
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
152.00
45.82
***.**
***.**
65.94
55.94
-10.12
156.00
44.92
***.**
***.**
65.83
55.83
-10.91
163.00
39.63
***.**
***.**
65.63
55.63
-16.00
192.00
39.33
***.**
***.**
64.80
54.80
-15.47
202.00
47.84
***.**
***.**
64.51
54.51
-6.67
208.00
41.29
***.**
***.**
64.34
54.34
-13.05
267.00
35.48
***.**
***.**
62.66
52.66
-17.18
272.00
35.51
***.**
***.**
62.51
52.51
-17.00
23050.00
33.71
***.**
***.**
60.00
50.00
-16.29
26220.00
30.73
***.**
***.**
60.00
50.00
-19.27
*The reading amplitudes are all under limit.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 17/19
Conducted Emission Test Result:
Test Mode: ET-913 1000 x 1000Mbps + ET-912 100 x 100Mbps 110Vac/60Hz
Testing room :
Temperature : 23 ° C
Humidity : 57 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
153.00
43.54
***.**
***.**
65.91
55.91
-12.37
163.00
34.63
***.**
***.**
65.63
55.63
-21.00
167.00
33.34
***.**
***.**
65.51
55.51
-22.17
205.00
40.30
***.**
***.**
64.43
54.43
-14.13
564.00
23.33
***.**
***.**
56.00
46.00
-22.67
1070.00
24.21
***.**
***.**
56.00
46.00
-21.79
22460.00
29.00
***.**
***.**
60.00
50.00
-21.00
23050.00
30.91
***.**
***.**
60.00
50.00
-19.09
23650.00
31.05
***.**
***.**
60.00
50.00
-18.95
26220.00
27.19
***.**
***.**
60.00
50.00
-22.81
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
151.00
48.29
***.**
***.**
65.97
55.97
-7.68
162.00
42.25
***.**
***.**
65.66
55.66
-13.41
167.00
40.77
***.**
***.**
65.51
55.51
-14.74
171.00
40.99
***.**
***.**
65.40
55.40
-14.41
181.00
37.38
***.**
***.**
65.11
55.11
-17.74
192.00
36.08
***.**
***.**
64.80
54.80
-18.72
202.00
47.34
***.**
***.**
64.51
54.51
-7.17
23050.00
35.50
***.**
***.**
60.00
50.00
-14.50
24120.00
30.84
***.**
***.**
60.00
50.00
-19.16
26220.00
29.99
***.**
***.**
60.00
50.00
-20.01
*The reading amplitudes are all under limit.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 18/19
Conducted Emission Test Result:
Test Mode: ET-913 1000 x 1000Mbps + ET-912 100 x 100Mbps 230Vac/50Hz
Testing room :
Temperature : 23 ° C
Humidity : 57 % RH
Line 1
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
150.00
39.97
***.**
***.**
66.00
56.00
-16.03
156.00
35.34
***.**
***.**
65.83
55.83
-20.49
161.00
34.71
***.**
***.**
65.69
55.69
-20.98
194.00
34.32
***.**
***.**
64.74
54.74
-20.42
202.00
43.53
***.**
***.**
64.51
54.51
-10.99
1021.00
25.14
***.**
***.**
56.00
46.00
-20.86
1091.00
27.12
***.**
***.**
56.00
46.00
-18.88
22460.00
29.73
***.**
***.**
60.00
50.00
-20.27
23050.00
36.78
***.**
***.**
60.00
50.00
-13.22
24120.00
31.00
***.**
***.**
60.00
50.00
-19.00
Line 2
READING AMPLITUDE
Frequency
(KHz)
LIMIT
Peak
Quasi-Peak
Average
Quasi-Peak
Average
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
Margin
(dB)
150.00
45.72
***.**
***.**
66.00
56.00
-10.28
158.00
39.47
***.**
***.**
65.77
55.77
-16.31
163.00
38.70
***.**
***.**
65.63
55.63
-16.93
167.00
37.13
***.**
***.**
65.51
55.51
-18.38
203.00
47.41
***.**
***.**
64.49
54.49
-7.07
267.00
33.96
***.**
***.**
62.66
52.66
-18.70
272.00
35.11
***.**
***.**
62.51
52.51
-17.40
22460.00
29.78
***.**
***.**
60.00
50.00
-20.22
23050.00
37.60
***.**
***.**
60.00
50.00
-12.40
24120.00
32.41
***.**
***.**
60.00
50.00
-17.59
*The reading amplitudes are all under limit.
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
Test Report --------------------------------------------------------------------------- 19/19
Appendix B
Radiated Emission Test Result:
Test Mode: ET-913 1000 x 1000Mbps + ET-912 100 x 100Mbps 110Vac/60Hz
Test Conditions:
Testing site
Frequency
MHz
:
Temperature :
Reading
Ant.
Amplitude
Height
dBµV/m
m
25° C
Table
degree
Humidity : 73 % RH
Correction
Corrected
Factors
Amplitude
dB
dBµV/m
Limit
Margin
dBµV/m
dB
(Horizontal)
250.0200
27.36
2.49
300
-1.80
25.56
37.00
-11.44
375.0300
29.90
2.49
279
3.15
33.05
37.00
-3.95
500.0350
24.37
1.01
65
6.80
31.17
37.00
-5.83
625.0300
20.64
1.01
215
10.40
31.04
37.00
-5.96
875.0513
21.12
1.01
128
15.65
36.77
37.00
-0.23
1000.0000
18.06
1.01
121
17.90
35.96
37.00
-1.04
250.0200
34.15
1.01
42
-1.80
32.35
37.00
-4.65
375.0300
28.86
2.50
293
3.15
32.01
37.00
-4.99
500.0250
27.26
1.01
152
6.80
34.06
37.00
-2.94
875.0438
19.12
2.50
230
15.65
34.77
37.00
-2.23
937.0775
10.71
2.50
199
17.16
27.87
37.00
-9.13
***
(Vertical)
***
Note:
1. Margin = Amplitude - limit, if margin is minus means under limit.
2. Corrected Amplitude = Reading Amplitude + Correction Factors
3. Correction factor = Antenna factor + ( Cable Loss - Amplitude gain )
(For example : 30MHz correction factor = 15.5 + (-15.26) = 0.24 dB/m)
Report No.: E3015050191
Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778
LABEL Format:
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Trade Name: EDIMAX
Model No.: ET-912, ET-913, ET-910MCR
LABEL Size: 40 X20 mm
LABEL Position:
LABEL
Canadian ICES-003
ET-913
ET-913
ET-913
ET-913
ET-913
ET-913
ET-912
ET-912
ET-912
ET-912
ET-912
ET-912