Preliminary Info
Meets the needs for simultaneous
Heat recovery system provides optimum individual comfort by FUJITSU GENERAL`s
High energy efficiency operation using
high efficient compressor !
0.1 Hz steps high precision inverter compressor control
New
Simple operation
large LCD
touch panel controller !
Wired remote controller with
the largest LCD touch panel in
the industry
Easy design and easy installation
with few restrictions !
Easy design and easy installation using
flexible piping connections and
RB units with few installation restrictions.
Supports speedy maintenance !
The indoor unit information can be checked using
the remote controller to support speedy maintenance.
INDOOR UNITS
2
4-way
Compact Cassette
4-way
Cassette
Low Static Pressure Duct /
Concealed Floor
Slim Duct /
Slim Concealed Floor
Medium
Static Pressure Duct
High
Static Pressure Duct
Floor / Ceiling
Ceiling
Wall Mounted
(EEV External)
Wall Mounted
cooling and heating operation
changing over from cooling to heating
8 to 48HP
System outline
A heat recovery system achieve high energy efficiency by drawing heat from the room
to be cooled and effectively using the heat as a heat energy for rooms to be heated.
Simultaneous
multaneous cooling and
d heating operation is possible by RB unit
Simultaneously as the cooling operation and
heating operation, energy saving is up.
High pressure liquid
Low pressure gas
High pressure gas
Heat exchanger
Heating & Cooling
High
4 way valve
Outdoor unit
COP
Compressor
Mainly Heating
Mainly Cooling
RB unit
it
Heating only
RB unit
Heat
exchanger
EEV
Indoor unit
0
Cooling
Cooling
Heating
Heating
50
Heating ratio
100 (%)
Heating
CONTROLLERS
Central Controller
Group
Remote Controller
Central
Remote Controller
Individual Controller
Touch Panel
Controller
System Controller
(Software)
Wireless
Simple
Remote Controller Remote Controller
Wired
Remote Controller
Wired
(Touch Panel)
Remote Controller
3
FEATURES
High Energy Efficiency
Energy efficiency technology boosted operation efficiency
Powerful large propeller fan
By using CFD*1 technology, A newly designed
fan achieves high performance and low noise
operation.
*1. CFD = Computational Fluid Dynamics
3 phase DC fan motor
Efficiency is substantially improved by high
efficient motor with sophisticated driver control.
In addition, low noise is realized by DC fan motor.
Subcool heat exchanger
High Heat Exchange efficiency is achieved by
using an internal projection shape double pipe
construction.
Sine-wave DC inverter control
High efficiency is realized by adoption of reduced
switching loss IPM.
4-face heat exchanger
Heat exchange efficiency is significantly
improved by the introduction of a new 4-face
heat exchanger that increases effective surface area.
Front intake port
(corner cut air inhaling structure)
In multiple outdoor unit installations, the unique
front intake design improves airflow into the Heat
Exchanger.
High efficient compressor
High efficient compressor speed control
Large capacity
DC inverter compressor
Large capacity high efficient DC twin
rotary compressor with excellent
intermediate capability.
Comfortable space with small room temperature changes and little
energy loss is created by 0.1Hz steps compressor speed control.
Capacity
0.1Hz
Inverter frequency
Ideal heat exchanger path control
Sophisticated operation control
Heat exchanger is split into top and bottom. Heat exchange
efficiency is improved by optimum heat exchanger path refrigerant
control. Refrigerant is more distributed at the top side heat
exchanger with a large intake
e air flow.
When multi units are connected, sophisticated operation is
performed by each compressor. Efficiency is improved by
operating the rotary compressor in the good efficiency low speed
range by using the heat exchangers to the full.
High efficient refrigerant flow control
Larger
refrigerant
flow
Fan
Large
intake
airflow
Compressor
Load level
Small
intake
airflow
Heat
exchanger
4
EEV Heat exchanger Distributor
Outdoor unit
High efficient operation
Inefficient operation
Comfort & Convenience
Simple operation Wired Remote Controller (Touch panel)
Wired Remote Controller equipped touch panel method with
LCD panel is not only provision of simple operation but also
can be managed with multi energy saving function.
Wide LCD touch
panel
Set temperature
display
Backlight
Room temperature
display
On/Off button
Multi language
support
Auto changeover function
At Auto setting, the cooling/heating mode is automatically switched
according to the set temperature and room temperature.
Automatic cooling/heating operation for each room
m is possible
2°C
0.5°C
Heating
Set Temp.
Room A
24°C
-0.5°C
-2°C
Cooling
Room B
18°C
time
Cooling operation
Cooling fan operation
Heating operation
Heating fan operation
Dry
Room C
27°C
Room D
OFF
Fan
Room E
23°C
Precision refrigerant flow control
Precision and Smooth refrigerant flow control is achieved by
using a DC Inverter control in conjunction with individual
indoor unit electronic expansion valve control. This allows for
a high precision comfortable temperature control within ±0.5°C
of set temperature.
±0.5˚C
High
Hot
Hot
Set temp.
Thermal change of the room
*Simulation in heating operation.
Comfortable operation is
achieved due to a small variation of
room temperature
Cold
Low
Reach the set temperature quickly
Quiet operation
Low noise mode
Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the usage
environment and outside temperature load.
Outdoor unit external input and setting from system controller are possible.
Capacity priority setting
Quiet priority setting
Air
conditioning
load factor
Capacity
Operating
sound
Heat load
Heat load
100%
down
100%
0
0
Rated
noise
level
Rated
noise
level
0
0
time
Quiet priority low noise mode
Alternated
automatically
Reset automatically
time
Capacity priority low noise mode
5
FEATURES
Design Flexibility
Overall piping length 1,000m
Flexible piping connection
Total pipe length
More flexible refrigerant piping work is possible to adjust floor layout and building structure
by various RB unit connection type.
1,000 m
Actual pipe length
165m max.
*2
Height difference between
outdoor and indoor units
50m max.
For the outdoor unit stated
below : 40m max.
Separation tube
RB Unit
((single type)
RB Unit
(multi type)
Max.3 or 8
indoor units
Single
connection
Max. 8 indoor unit
Multiple
connection
Single
Multiple
&
connection
connection
*1 Cooling only
connection
・The RB unit can be freely positioned between the first branch and the indoor unit.
・The maximum height difference between RB units is 15 m.
Pipe length from first
separation tube to the
farthest indoor unit
*1. RB Unit is not necessary for cooling only use.
60m max.
Height difference
between indoor and
indoor units
15m max.
*2. Note : When there is 1 outdoor unit, the maximum is 700m.
High static pressure of 80Pa
Large diameter fan and 3 phase DC motor has been utilized allowing an external static pressure of
80Pa. This allows outdoor units to be installed within balcony, etc. on each floor in high rise
buildings.
80 Pa
as standard
High capacity connection
Various combination from 8HP to 48HP with 2HP
increments. 12 types, 55 models of indoor units can be
selected ranging from 2.2kW to 25kW in capacity.
A maximum of 150% indoor unit connectable capacity.
6
Connectable indoor
unit capacity
Connectable indoor
unit number
50% to 150%
up to 64
Installation Example
Easy Installation
Flexible installation of RB unit
・Small & slim design saves space
・A drain pipe is not required
・The control box position can be changed to
meet the installation conditions
Height
198mm
RBunit (single type)
Both-sides installation freedom of the
control box
Upper-sides installation of the
control box in a narrow space
・Small design saves space
・A drain pipe is not required
・Simple installation series connection design
•2-way connection
•Up to 2 units can be
connected in series.
RBunit (multi type)
Simple wiring work
Installation is made as the communication wiring can be
connected continiously to RB units and outdoor units.
Note: In a multiple refrigerant system installation, Automatic
addressing sequence cannot be initiated
Up to maximum
length
RB Unit
3,600m
or
Parallel connection
Serial connection
Automatic address setting
The address of each indoor unit, RB unit,
and Signal Amplifier can be automatically
set by button switch of outdoor unit.
Automatic address setting is
performed at outdoor unit
Addresses are automatically
distributed from outdoor unit.
1 Signal Amplifier
RB unit
3
3
7
7
2
Press the pushbutton
switch of outdoor unit.
2
1
4
0
1
4
0
5
5
6
6
Manual address setting from indoor unit and remote controller is also possible.
7
FEATURES
High Reliability
Life-extending operation
Rotation
Outdoor unit rotational operation
The compressor starting order is rotated
so that the running time is shared.
Rotation
Rotation
DC
1
DC
2
DC
1
DC
3
DC
3
DC
2
DC
1
DC
3
DC
2
Note: Rotational operation is alternated by the start / stop timing of the compressor.
Backup operation
If one compressor fails, backup operation will be performed by
the remaining compressors as emergency*.
*:Note: Backup operation may not be possible depending on the trouble state.
Equalization refrigerant control
Introduced innovative compresoor control logic in order to balance
refrigerant mass flow rate of each outdoor unit by controlling
inverter speed.
ON
ON
ON
ON
ON
OFF
DC
1
DC
2
DC
3
DC
1
DC
2
DC
3
Master
Slave 1
Slave 2
Master
Slave 1
Slave 2
Load level
Unbalance operation condition
Balance operation condition
Liquid back flow protection
By adopting a large sized accumulator, the refrigerant which is
not completely vaporized is left inside the accumulator and only
a stable gas is fed to the compressor.
from
Evapolator
Compressor
Accumulator
Large sized
Accumulator
Adoption of blue fin heat exchanger
Corrosion resistant of the heat exchanger has been
improved by the introduction of blue fin treatment to the
outdoor unit’s heat exchanger.
Blue fin heat exchanger
Cobalt Blue protection
Standard chromate protection
Aluminium base material
Hydrophilic coating
8
Easy Maintenance & Service
Various information or error status can be checked easily via
Wired Remote Controller
Address, sensor values, and error status can be checked.
Setting status
Indoor unit address
Error status/
Error history
Sensor value
Wired Remote Controller
(Touch panel)
Design for easy service and maintenance
Inspection and replacement of main parts are easier due to innovative construction and an LED operational display.
Consolidated electrical
components make
maintenace easy.
Easy-to-read 7-segment LED display
which explains operational and trouble
status
Split front panel allows for
maintenance from top or
bottom of the outdoor unit
Movable PCB panel
that allows for easier
maintenance work
behind the PCB.
Expansion of work space
Ma
Main
Ma
Maintenance
of electrical components,
valves, and compressor parts from the front is
possible.
Solenoid valve can be removed
from the side.
Electrics box can be temporarily
fixed by sliding down.
Trouble diagnosis by Service Tool
Suitable maintenance is possible by analysis of the
operation data. Connection anywhere in the VRF
network system is easy.
Outdoor unit
Service Tool
UTY-ASGX
Transmission line
USB adaptor
(Field supplied)
Intdoor
unit
Easy to
carry out with
USB adaptor
9
LINEUP
Outdoor units lineup
Space saving combination
Rating Capacity range
8
10
12
14
16
18
20
22
24
AJ*A72GALH
AJ*A90GALH
AJ*108GALH
AJ*126GALH
AJ*144GALH
AJ*162GALH
AJ*180GALH
AJ*198GALH
AJ*216GALH
HP
Model name
Energy efficiency combination
Rating Capacity range
16
22
24
26
28
30
AJ*144GALHH
AJ*198GALHH
AJ*216GALHH
AJ*234GALHH
AJ*252GALHH
AJ*270GALHH
HP
Model name
Dimensions
(Unit : mm)
690 (Bolt pitch)
80 530 (Bolt pitch)
8, 10, 12HP
8-12×17 (Hole)
732 (Bolt pitch)
AJ*A72GALH / AJ*A90GALH / AJ*108GALH
765
C
Bottom side knockout position
82
80
1339
1576
1690
Pipe port
Top view
190
42
B
A
C
930
A
Front side knockout position
Ø 34.5
Power supply cable port
Ø 43.7
Power supply cable port
73
Ø 22.2
Transmission
cable port
100
10
Pipe port
125
199
10
Left side knockout position
Ø 22.2
Transmission cable port
75
95
43
Ø 50
Power supply
cable port
B
AJ* : AJY(FUJITSU), AJH(GENERAL)
Ø 50
Power supply
cable port
Ø 22.2
Transmission
cable port
Ø 34.5
Power supply cable port
Ø 43.7
Power supply cable port
Ø 22.2
Transmission
cable port
26
28
30
32
34
36
38
40
42
44
46
48
AJ*234GALH
AJ*252GALH
AJ*270GALH
AJ*288GALH
AJ*306GALH
AJ*324GALH
AJ*342GALH
AJ*360GALH
AJ*378GALH
AJ*396GALH
AJ*414GALH
AJ*432GALH
32
34
36
38
40
42
44
AJ*288GALHH
AJ*306GALHH
AJ*324GALHH
AJ*342GALHH
AJ*360GALHH
AJ*378GALHH
AJ*396GALHH
(Unit : mm)
14, 16HP
1000 (Bolt pitch)
840 (Bolt pitch)
80
8-12×7 (Hole)
732 (Bolt pitch)
AJ*126GALH / AJ*144GALH
1690
765
B
A
C
1240
11
OUTDOOR UNITS
Specifications
Space saving combination
Rating Capacity range
HP
Model name
Unit 1
Unit 2
Unit 3
Maximum Connectable Indoor Unit*1
Indoor unit connectable capacity
Cooling
kW
8
10
12
14
16
18
20
22
24
AJ*A72GALH
AJ*A90GALH
AJ*108GALH
AJ*126GALH
AJ*144GALH
AJ*162GALH
AJ*180GALH
AJ*198GALH
AJ*216GALH
AJ*A72GALH
AJ*A90GALH
AJ*108GALH
AJ*126GALH
AJ*144GALH
AJ*A90GALH
AJ*A72GALH
AJ*A90GALH
AJ*A90GALH
AJ*108GALH
AJ*A90GALH
AJ*108GALH
AJ*108GALH
15
16
17
21
24
27
30
32
35
11.2-33.6
14.0-42.0
16.8-50.2
20.0-60.0
22.4-67.2
25.2-75.6
28.0-83.9
30.8-92.3
33.5-100.5
22.4
28.0
33.5
40.0
45.0
50.4
56.0
61.5
67.0
25.0
31.5
37.5
45.0
50.0
56.5
63.0
69.0
75.0
80
80
80
80
80
80
80
80
80
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Power source
Capacity
3-phase 4 wire , 400 V, 50Hz
Cooling
kW
Heating
Maximum external static pressure
Pa
Heat exchanger fin
Dimensions
Connection
pipe diameter
Operation
range
Height
mm
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
Width
mm
930
930
930
1,240
1,240
930×2
930×2
930×2
930×2
Depth
mm
765
765
765
765
765
765
765
765
765
Liquid
12.70
12.70
12.70
12.70
12.70
15.88
15.88
15.88
15.88
Discharge Gas mm
15.88
19.05
19.05
22.22
22.22
22.22
22.22
28.58
28.58
Suction Gas
22.22
22.22
28.58
28.58
28.58
28.58
28.58
34.92
34.92
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
Cooling
˚C
Heating
Energy efficiency combination
Rating Capacity range
HP
Model name
Unit 1
Unit 2
Unit 3
Maximum Connectable Indoor Unit*1
Indoor unit connectable capacity
kW
Cooling
16
22
24
26
28
30
AJ*144GALHH
AJ*198GALHH
AJ*216GALHH
AJ*234GALHH
AJ*252GALHH
AJ*270GALHH
AJ*A72GALH
AJ*A72GALH
AJ*126GALH
AJ*A72GALH
AJ*A72GALH
AJ*A72GALH
AJ*A72GALH
AJ*A90GALH
AJ*A72GALH
AJ*A72GALH
AJ*A90GALH
AJ*A90GALH
AJ*A72GALH
AJ*A90GALH
AJ*A90GALH
AJ*A90GALH
24
33
36
39
42
45
22.4-67.2
31.2-93.6
33.6-100.8
36.4-109.2
39.2-117.4
42.4-127.2
44.8
62.4
67.2
72.8
78.4
84.0
50.0
70.0
75.0
81.5
88.0
94.5
80
80
80
80
80
80
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Power source
Capacity
3-phase 4 wire, 400 V, 50Hz
Cooling
kW
Heating
Maximum external static pressure
Pa
Heat exchanger fin
Dimensions
Connection
pipe diameter
Operation
range
Height
mm
1,690
1,690
1,690
1,690
1,690
1,690
Width
mm
930×2
930+1,240
930×3
930×3
930×3
930×3
Depth
mm
765
765
765
765
765
765
Liquid
12.70
15.88
15.88
15.88
15.88
19.05
Discharge Gas mm
22.22
28.58
28.58
28.58
28.58
28.58
Suction Gas
28.58
34.92
34.92
34.92
34.92
34.92
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
Cooling
Heating
˚C
AJ* : AJY(FUJITSU), AJH(GENERAL)
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
12
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
When cooling operation will be conducted at outdoor air temperature below -5°C,
the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.
26
28
30
32
34
36
38
40
42
44
46
48
AJ*234GALH
AJ*252GALH
AJ*270GALH
AJ*288GALH
AJ*306GALH
AJ*324GALH
AJ*342GALH
AJ*360GALH
AJ*378GALH
AJ*396GALH
AJ*414GALH
AJ*432GALH
AJ*144GALH
AJ*90GALH
AJ*144GALH
AJ*108GALH
AJ*144GALH
AJ*126GALH
AJ*144GALH
AJ*144GALH
AJ*108GALH
AJ*108GALH
AJ*A90GALH
AJ*108GALH
AJ*108GALH
AJ*108GALH
AJ*144GALH
AJ*108GALH
AJ*A90GALH
AJ*144GALH
AJ*108GALH
AJ*108GALH
AJ*144GALH
AJ*144GALH
AJ*A90GALH
AJ*144GALH
AJ*144GALH
AJ*108GALH
AJ*144GALH
AJ*144GALH
AJ*126GALH
AJ*144GALH
AJ*144GALH
AJ*144GALH
39
42
45
48
50
53
57
60
63
64
64
64
36.8-110.3
39.3-117.8
42.5-127.5
45.0-135.0
47.5-142.5
50.3-150.8
53.5-160.5
56.0-168.0
59.3-177.8
61.8-185.3
65.0-195.0
67.5-202.5
73.0
78.5
85.0
90.0
95.0
100.5
106.5
112.0
118.5
123.5
130.0
135.0
81.5
87.5
95.0
100.0
106.5
112.5
119.0
125.0
131.5
137.5
145.0
150.0
80
80
80
80
80
80
80
80
80
80
80
80
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
3-phase 4 wire , 400 V, 50Hz
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
1,690
930+1,240
930+1,240
1,240×2
1,240×2
930×3
930×3
930×2+1,240
930×2+1,240
930+1,240×2
930+1,240×2
1,240×3
1,240×3
765
765
765
765
765
765
765
765
765
765
765
765
15.88
15.88
19.05
19.05
19.05
19.05
19.05
19.05
19.05
19.05
19.05
19.05
28.58
28.58
28.58
28.58
28.58
28.58
34.92
34.92
34.92
34.92
34.92
34.92
34.92
34.92
34.92
34.92
34.92
41.27
41.27
41.27
41.27
41.27
41.27
41.27
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
32
34
36
38
40
42
44
AJ*288GALHH
AJ*306GALHH
AJ*324GALHH
AJ*342GALHH
AJ*360GALHH
AJ*378GALHH
AJ*396GALHH
AJ*126GALH
AJ*A90GALH
AJ*A72GALH
AJ*126GALH
AJ*A90GALH
AJ*A90GALH
AJ*126GALH
AJ*126GALH
AJ*A72GALH
AJ*126GALH
AJ*126GALH
AJ*A90GALH
AJ*144GALH
AJ*126GALH
AJ*A90GALH
AJ*126GALH
AJ*126GALH
AJ*126GALH
AJ*144GALH
AJ*126GALH
AJ*126GALH
48
51
54
57
60
64
64
44.9-134.1
48.0-143.8
51.2-153.6
54.0-162.0
56.8-170.2
60.0-180.0
62.5-187.5
90.4
96.0
102.4
108.0
113.0
120.0
125.0
101.5
108.0
115.0
121.5
126.5
135.0
140.0
80
80
80
80
80
80
80
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
Blue fin
3-phase 4 wire, 400 V, 50Hz
1,690
1,690
1,690
1,690
1,690
1,690
1,690
930×2+1,240
930×2+1,240
930+1,240×2
930+1,240×2
930+1,240×2
1,240×3
1,240×3
765
765
765
765
765
765
765
19.05
19.05
19.05
19.05
19.05
19.05
19.05
28.58
28.58
28.58
34.92
34.92
34.92
34.92
34.92
34.92
41.27
41.27
41.27
41.27
41.27
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-10 to 46
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
-20 to 21
*1 Minimum connectable indoor unit number is 2.
13
INDOOR UNITS
Indoor Unit Lineup
12 Types, 55 Models, Capacity range from 2.2kW to 25.0kW
Capacity range (kW)
Model code
2.2
2.8
3.6
4.5
7
9
12
14
4-way Compact Cassette
AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH
Cassette
4-way Cassette
Low Static Pressure Duct
ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH
Slim Duct
(Drain pump internal)
ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH
Concealed Duct
Medium Static Pressure Duct
High Static Pressure Duct
Floor standing
(*Same as Ceiling models)
AB*A12GATH
Floor
AB*A14GATH
Concealed Floor mounted
(*Same as Low Static Pressure Duct models)
ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH
Slim Concealed Floor mounted
(*Same as Slim Duct models)
ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH
Ceiling
Ceiling
AB*A12GATH
AB*A14GATH
AS*A1GACH
AS*A14GACH
Wall Mounted
AS*A07GACH
Wall Mounted
AS*A09GACH
Wall Mounted
(EEV external)
AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH
With this model, connection of EV kit is necessary.
AB* : ABY(FUJITSU), ABH(GENERAL)
14
AS* : ASY(FUJITSU), ASH(GENERAL)
Comprehensive range of indoor units of variety design and capacity ranges
available which can be selected to suit any air conditioning needs.
5.6
7.1
9.0
11.2
12.5
14.0
18.0
22.4
25.0
18
24
30
36
45
54
60
72
90
AUXB18GALH AUXB24GALH
AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH
ARXB18GALH ARXB24GALH ARXB30GALH ARXB36GALH ARXB45GALH
ARXD18GALH ARXD24GALH
ARXA24GALH ARXA30GALH ARXA36GALH ARXA45GALH
ARXC36GATH ARXC45GATH
AB*A18GATH
ARXC60GATH ARXC72GATH ARXC90GATH
AB*A24GATH
ARXB18GALH
ARXD18GALH ARXD24GALH
AB*A18GATH
AB*A24GATH
AB*A30GATH
AB*A36GATH
AB*A45GATH
AB*A54GATH
AS*A18GACH AS*A24GACH AS*A30GACH
15
CONTROLLER
Control System
Every user's needs are supported by offering a variety of controls, such as individual
control, central control and building management control options.
Building
Management
Air Conditioning
Central Control
Air Conditioning
Individual Control
System
Outdoor unit
System Controller (Software)
UTY-APGX
UTY-PEGX(Option)
USB
Adaptor *2
Wired Remote Controller
(Touch panel)
UTY-RNR*
Indoor unit
(Field supplied)
Outdoor unit
R*:RY(FUJITSU), RG(GENERAL)
Internet or Public
Telephone Line
Wired Remote Controller
UTY-RNK*
Indoor unit
Remote/Monitoring side
K*:KY(FUJITSU), KG(GENERAL)
Touch Panel Controller
UTY-DTG*
Simple Remote Controller
UTY-RSK*
G*:GY(FUJITSU), GG(GENERAL)
Signal Amplifier
UTY-VSGXZ1
Central Remote Controller
UTY-DCG*
K*:KY(FUJITSU), KG(GENERAL)
Simple Remote Controller
UTY-RHK*
Without
operation mode
G*:GY(FUJITSU), GG(GENERAL)
General-purpose
Building Control Computer
Group Remote Controller
UTY-CGG*
Network
Convertor
IR Receiver Unit
UTB-YWC
K*:KY(FUJITSU), KG(GENERAL)
Connectable to
various sized BMS/BAS*1
G*:GY(FUJITSU), GG(GENERAL) UTY-VGGXZ1
BACnet ® Gateway (Software)
UTY-ABGX
IR Receiver Unit
UTY-LRH*B1
USB
Adaptor *2
(Field supplied)
or
Wireless Remote Controller
UTY-LNH*
H*:HY(FUJITSU), HG(GENERAL)
Network Convertor
(BMS / LONWORKS® )
UTY-VLGX
Card-key
*B:YB(FUJITSU),
GB(GENERAL)
External
Switch Controller
UTY-TEKX
For single split
(Field supplied)
Web Monitoring
Tool (Software)
UTY-AMGX
USB
Adaptor*2
Internet or
Public Telephone Line
(VRF system side)
(Field supplied)
(Monitoring side)
*1. BMS/BAS: Building Management System / Building Automation System
*2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.
The devices above cannot be connected to the S series.
(Except System Controller & BACnet® Gateway)
16
Network
Convertor
UTY-VGGXZ1
Service Tool (Software)
UTY-ASGX
USB
Adaptor*2
(Field supplied)
Transmission line (VRF Network)
LONWORKS ® Network
Module link
Ethernet
Remote controller line
Signal line(Single split system)
USB cable
Group Remote Controller line
Individual controller
Wired Remote Controller (Touch panel)
Max. controllable
16
UTY-RNR*
indoor units
•Easy finger touch operation with LCD panel
•Built-in weekly/Daily timer(ON/OFF,Temp.,Mode)
•Temperature upper and lower limit setting
•Background light enables easy operation in a darkened room
•Anti-cool /Anti-heat and Anti-freeze setting
•Room temperature display
•Control up to 16 indoor units
•Corresponds to 7 different languages •Non-polar 2 wires
R*:RY(FUJITSU), RG(GENERAL)
Wired Remote Controller
Max. controllable
16
UTY-RNK*
indoor units
The room temperature can be controlled by detecting the temperature accurately from the built-in sensor
•Simple operation with Built-in Weekly / Daily Timer.
•Control up to 16 indoor units.
•Up to 2 wired remote controllers can be connected to a single indoor unit.
K*:KY(FUJITSU), KG(GENERAL)
Simple Remote Controller
UTY-RSK*
UTY-RHK* (Without operation mode)
Max. controllable
16
indoor units
Compact remote controller provides access to basic functions
•Up to 16 indoor units can be controlled with one remote controller.
•Suitable for hotels or offices as it is easily operated with no complex functions.
UTY-RSK*
UTY-RHK*
Without operation mode
K*:KY(FUJITSU), KG(GENERAL)
Wireless Remote Controller
Max. controllable
16
UTY-LNH*
indoor units
Selectable
Simple and sophisticated operations with a choice of 4 daily timers
4
•A single controller controls up to 16 indoor units.
daily timers
UTY-LNH*
H*:HY(FUJITSU), HG(GENERAL)
IR Receiver Unit
UTB-YWC
Necessary to control for all duct type by Wireless Remote Controller
Wireless
Remote Controller
IR Receiver Unit
IR Receiver Unit
UTY-LRH*B1
Cassette type indoor unit can be controlled
with Wireless Remote Controller
IR Receiver Unit
*B:YB(FUJITSU), GB(GENERAL)
Wireless
Remote Controller
17
OTHERS
Control System
Central controller
Group Remote Controller
Max. controllable
UTY-CGG*
group R.C. in a VRF
network system
Group control of indoor units with simple operation
Max. controllable
64
8
•Up to 8 remote controller groups can be controlled by one Group Remote Controller.
•Up to 64 Group Remote Controllers can be connected in one VRF network system.
•Network Convertor is required to connect Group Remote Controllers to a VRF
network system.
(Network Convertor allows up to 4 Group Remote Controllers)
remote
controller groups
G*:GY(FUJITSU), GG(GENERAL)
Central Remote Controller
Max. controllable
100
UTY-DCG*
Indoor units
Central control of small- and medium-sized buildings and tenants.
Max. controllable
16
• Individual control and monitor of 100 indoor units
groups
• 5 inch TFT color screen
• User friendly view and easy operation
• External input / output contact
• Detachable power supply unit
• Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish.
Touch Panel Controller
G*:GY(FUJITSU), GG(GENERAL)
Max. controllable
400
UTY-DTG*
indoor units
•Large-sized 7.5-inch TFT color
•Easy finger touch operation with LCD panel
•Stylish shape and design to suit all application
•No additional component is required for installation
•Up to 400 indoor units can be controlled
•Selectable 2 display types (Icon / List) in monitoring mode
•Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.
System Controller
Software
UTY-APGX
UTY-PEGX (Energy manager- Option)
G*:GY(FUJITSU), GG(GENERAL)
Max. controllable
Max. controllable
Max. controllable
VRF network systems
outdoor units
indoor units
4
400
1,600
System Controller realizes the advanced integrated monitoring & control of VRF network system
from small scale buildings to large scale buildings.
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled.
• Supports VRF VR-II as well as J-II and V-II series.
• In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and
energy saving functions are strengthened and building manager and owner needs are met.
• Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish)
Service & Maintenance Tool
Service Tool
Software
UTY-ASGX
Max. Monitor
and controll
Max. Monitor
and controll
indoor units
outdoor units
400
Extensive monitoring and analysis functions for installation and maintenance
•Operation status can be checked and analyzed to detect even the smallest abnormalities
•Storage of data on system operation status on a PC allows access even from off site.
•Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large
scale buildings or hotels
•This software can be connected to any point of transmission line with USB adaptor (field supplied).
•Supports VRF VR-II as well as J-II and V-II series
18
100
Service & Maintenance Tool
Web Monitoring Tool
VRF network system
can be supported
Software
4
1,600
UTY-AMGX
Product features
•Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks.
•Error notification can be automatically transmitted to several locations using the internet*1.
•Requires either a dedicated internet connection or public telephone line.
•Determination of an error occurrence can be made through error warnings and equipment status information obtained
from a remote location.
•Supports VRF VR-II as well as J-II and V-II series
indoor units
can be supported
*1: Use of internet mail system required.
Convertor/Adaptor
External Switch Controller
UTY-TEKX
Air conditioner switching can be controlled by connecting other sensor switches
•In combination with a field supply Card-Key Switch or other sensor, the External Switch
Controller allows control of the ON / OFF, Room temperature, Fan speed and Master
control functions. This makes this product suitable for installations such as hotel rooms.
Network Convertor
Max. controllable
16
UTY-VGGXZ1
Network
Convertor units
•This network convertor is to be used for connecting single split system or group
remote controller with the VRF network system.
Please select the function by switching the dip switch during the installation.
Network Convertor for LONWORKS®
Max. controllable
Max. controllable
Units to BMS
indoor units
Max. controllable
Max. controllable
Max. controllable
VRF network systems
outdoor units
indoor units
4
UTY-VLGX
128
•For connection between VRF network system and a LONWORKS ® open network for
management of small to medium-sized BMS and VRF network system.
•The UTY-VLGX permits central monitoring and control of a VRF network system from a BMS
through a LONWORKS ® interface.
BACnet® Gateway
UTY-ABGX
Software
4
400
•The VRF network system can be incorporated into a Building Management System.
•Enables central control of up to 1,600 indoor units through BACnet®, a global standard for
open networks.
•Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller
(B-ASC) BACnet® / IP over Ethernet.
•Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway.
•Supports VRF VR-II as well as J-II and V-II series
1,600
CD-ROM
(Software)
Software
Protection Key
Signal Amplifier
UTY-VSGXZ1
•Transmission Line length can be extended up to 3,600m with multiple Signal Amplifier.
•Multiple Signal Amplifier are required according to the total wiring length or total number of
connectable units.
•A Signal Amplifier has filter function for communication. It is required every VRF refrigerant
system in a parallel transmission connection when the total number of indoor units exceeds 320.
19
O
OTHERS
S
Refrigerant piping parts
RB unit
Single
g type
yp
Type
Model name
Number of branch
Total connection capacity of indoor unit
per 1 connection port(Q)
kW
Number of connectable indoor unit per
1 connction port
Dimensions (H×W×D)
Fujitsu General (Thailand) Co., Ltd.
UTP-RX01AH
UTP-RX01BH
UTP
RX01BH
UTP-RX01CH
UTP-RX04BH
UTP
RX04BH
1
1
1
4
Q 8.0
Q 18.0
Q 28.0
Q 18.0
8
8
3
8
198X298X268
mm
ISO 9001
ISO 14001
Certified number : 01 100 89394 Certified number : 01 104 9245101
Multi type
yp
ISO 9001
Certified number : 01 100 79269
ISO 14001
Certified number : 272043
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001
Certified number : 00608Q11061R2M
260X654X428
ISO 14001
Certified number : 00609E20454R2M
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
N807
All products specified in this brochure
comply with the Australian
Communications Authority's (ACA)
requirements for Electromagnetic
“
” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan, the U.S.A and other countries or areas.
*Microsoft ® and Windows ® are registered trademarks of Microsoft Corporation in the United States.
*Adobe ® Reader® are registered trademarks of Adobe Systems Incorporated in the United States.
*Intel ®, Pentium ® and Celeron ® are registered trademark of Intel Corporation or its subsidiaries in the United States.
*AMD AthlonTM and AMD DuronTM are registered trademark of Advanced Micro Devices, Inc.
*Echelon ®, LONWORKS ®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries.
*BACnet ® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE).
The colors may be different from the actual colors because this catalog is printed matter.
Product specifications are subject to change without notice.
Distributed by :
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
http://www.fujitsu-general.com/
Copyright© 2012 Fujitsu General Limited. All rights reserved.
6NNR20-1201E