Comfort Module Range for Monobloc Heat Pumps
Quality
Management
Systems
Comfort module with two-zone kit
Single-zone comfort module
80HMA
Nominal heating capacity 4-20 kW
Nominal cooling capacity 4-20 kW
The new comfort module range for monobloc inverter
heat pumps offers a complete heating system that is easy
to design and install.
System controls ensure optimised energy efficiency, using
auto-adaptative weather compensation control that
constantly monitors the indoor and outdoor climate to
optimise the heat pump energy efficiency and deliver
perfect indoor climate.
With its improved aesthetics and compactness, combined
with new features and options, the new comfort module
sets new standards in energy savings and comfort. Using
the two-zone kit, two different terminal unit types or two
independent comfort zones can be closely monitored.
Domestic hot water production is made easy and can be
interfaced with thermal solar panels.
Features
■■
■■
■■
■■
■■
■■
■■
■■
■■
Reversible operation.
Electric booster heater or boiler back-up.
Auto-adaptative weather compensation control.
Dual comfort zone with independent control of two
terminal unit types.
Domestic hot water production control with possible
interfacing with thermal solar panels.
Easy-to-read user interface with weekly scheduling and
quick-access settings: comfort, eco and night mode.
Swimming pool heating control (optional)
Heat exchanger to create primary and secondary water
loop when using frost protection (optional field
installation in comfort module)
Circulation pump with high head pressure (optional)
New user interface
■■ The comfort module has an easy-to-use user interface with
easy-to-read LCD screen. It provides enhanced control
capability for maximised performance, reliability and indoor
comfort and has extended programming features such as
weekly scheduling. The sleek contemporary design blends
in with any room decor.
Domestic hot water tank
■■ With or without connection to a thermal solar panel, 200
or 300-litre tank. Built-in electric heater back-up and
anti-legionnella protection, controlled by the comfort
module, make domestic hot water readily available, safe
and energy-efficient.
Two-zone kit
■■ The new design facilitates the installation process and
makes two independent comfort zones easy to control.
This kit includes a hydronic disconnection collector, the
necessary circulating pumps and modulating valve. Installed
together with the domestic hot water tank, the two-zone
kit can integrate all accessories, such as the diverting valve
and T-connection.
Swimming pool heating control kit
■■ This control box, fitted with all necessary sensors and for
wall-mounting next to the comfort module, controls
swimming pool heating, using the heat pump. Hot water
from the heat pump is sent from the space heating system to
the swimming pool by controlling a diverting valve similar
to the one used for domestic hot water (field supply).
Swimming pool heating can be in accordance with a time
schedule that defines priorities between space heating/
cooling, domestic hot-water production and swimming pool
heating. An field-supplied intermediate heat exchanger,
fitted with the necessary circulating pumps, is mandatory
to ensure that water from the swimming pool is not used
for the space heating system.
Intermediate heat exchanger
■■ When adding antifreeze to the water loop, this option
allows limiting the use of antifreeze between heat pump
and comfort module by creating a primary and secondary
water loop.
Heat pump compatibility
■■ All 30AWH-HC sizes are compatible with the 80HMA
comfort module range. Comfort module controls can also
manage up to eight 30AWH units. A parallel hydronic
coupling of the unit to a tank is necessary (field supply).
■■ 30RQ 017 to 021 and 61AF 014 to 019 units are also
compatible, but the water volume of this installation must
be checked by a professional and comply with the heat
pump size minimum requirements. Depending on the
terminal unit type installed with the Carrier system a
buffer tank may have to be added.
2
Type key
Indoor unit (comfort module)
80HMA M
Product range
03
03 - 06 - 09 - Back-up electric heater size in kW
00 - For boiler back-up
M = single-phase model
T = three-phase model
Unit description
Part number
80HMA-M00
80HMA-M03
80HMA-M06
80HMA-T06
80HMA-T09
Indoor unit, reversible, 1 zone, for boiler back-up
Indoor unit, reversible, 1 zone, 3 kW 1-ph electric heater back up
Indoor unit, reversible, 1 zone, 6 kW 1-ph electric heater back up
Indoor unit, reversible, 1 zone, 6 kW 3-ph electric heater back up
Indoor unit, reversible, 1 zone, 9 kW 3-ph electric heater back up
Combination table, indoor and outdoor units
Outdoor unit (heat pump)
30AWH04HC Nominal capacity 4 kW
30AWH06HC Nominal capacity 6 kW
30AWH08HC Nominal capacity 8 kW
30AWH12HC Nominal capacity 12 kW
30AWH15HC Nominal capacity 15 kW
Indoor unit (comfort module)
80HMA-M00
Reversible, 1 zone, maximum heating capacity 20 kW for boiler back-up application
80HMA-M03
Reversible, 1 zone, maximum heating capacity 20 kW with 3 kW 1-phase electrical heater booster
80HMA-M06
Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 1-phase electrical heater booster
80HMA-T06
Reversible, 1 zone, maximum heating capacity 20 kW with 6 kW 3-phase electrical heater booster
80HMA-T09
Reversible, 1 zone, maximum heating capacity 20 kW with 9 kW 3-phase electrical heater booster
NOTE: All 30AWH sizes are compatible with the 80HMA comfort module range. Comfort module controls can also manage up to eight 30AWH units. A parallel hydronic
coupling of the unit to a tank is necessary (field supply). 30RQ 017 to 021 and 61AF 014 to 019 units are also compatible, but the water volume of this installation must
be checked by a professional and comply with the heat pump size minimum requirements. Depending on the terminal unit type installed with the Carrier system a buffer
tank may have to be added.
Accessories
Part No.
33AW-CB02
33AW-CS3
Description
Communication kit
Additional user interface
33AW-RAS02
Remote outdoor sensor
60STS020E03
60STS030E03
60STD020E03
60STD030E03
80AW9023
Domestic hot water tank, 1 coil - 200 l
Domestic hot water tank, 1 coil - 300 l
Domestic hot water tank, 2 coils - 200 l
Domestic hot water tank, 2 coils - 300 l
Domestic hot-water three-way valve and actuator
Advantages
To be installed in 30AWH
Monitors two independent comfort zones or used together with
comfort module interface
Positioned in the right place, the OAT sensor maximises comfort
compared to using the condensing unit OAT sensor.
Storage, 200 l of domestic hot water
Storage, 300 l of domestic hot water
Storage, 200 l of domestic hot water with thermal solar panel connection
Storage, 300 l of domestic hot water with thermal solar panel connection
Necessary to connect domestic hot water tank.
80AW9024
Thermal cut-out, floor heating
Stops circulation pump when supply temperature is too high
80AW9026
80AW9028
Piping kit to install domestic hot-water valve and
actuator (80AW9023) inside the unit
Cover panel to install two-zone kit (80HMA-9001)
detached from comfort module
Kit to add three-way valve and actuator in second zone
80HMA-9001
80HMA-9002
Two-zone kit
Pool kit
80HMA-9003
Pump kit
80HMA-9004
BPHE kit (for heat pumps up to 8 kW)
80HMA-9005
BPHE kit (for heat pumps up to 16 kW)
Specific DHW piping kit for the installation, used together with
80HMA-9001
Hides piping and connections, if two-zone kit is installed remotely
from the main comfort module.
Necessary to include domestic hot-water three-way valve in second
zone kit
Allows independent control of two comfort zones
Control box with all necessary sensors required to control three-way
valve to divert flow
Necessary when available heat pump pressure is too low for the
installation
Separate heat pump loop (with glycol) from indoor loop; includes
BPHE and pump
Separate heat pump loop (with glycol) from indoor loop; includes
BPHE and pump
80AW9027
Use
30AW---HC
80HMA, 80HMA9001, 80HMA-9002
80HMA
80HMA
80HMA
80HMA
80HMA
80HMA, 60ST,
80HMA-9002
80HMA, 80HMA9001, 80HMA-9002
30HMA-9001
80HMA-9001
80HMA-9001
80HMA
80HMA
80HMA
80HMA
80HMA
3
Physical data
Indoor unit (comfort module)
Number of comfort zones
Electric booster element
Number of auxiliary heating steps
Connection of back-up boiler
Dimensions, H x L x D
Operating weight
Power supply
Recommended circuit breaker size
kW
mm
kg
V-ph-Hz
80HMA-M00
1
0
1 (external boiler)
Yes
800 x 450 x 320
34
230-1-50
C6
80HMA-M03
1
3
1
No
800 x 450 x 320
35
230-1-50
C20
Electrical data
Comfort module 80HMA
Power supply
Voltage range
Max. power consumption, board and auxiliary devices
Board and auxiliary circuit breaker protection (not included)
Electric heater power consumption
Electric heater circuit breaker protection (not included)
Max. operating current
Main power cable size
Communication cable (FROH2R)
User interface (additional or remote) cable (FROH2R)
Booster heater power supply cable (H05VV-F)
Booster heater activation cable (FROH2R)
Domstic hot water sensor cable (FROH2R)
Remote outdoor sensor cable (FROH2R)
V-ph-Hz
V
kW
kW
A
mm2
mm2
mm2
mm2
mm2
mm2
mm2
M00
230-1-50
207-253
1.15
C6
0
C6
5
3G x 2.5
2 x 0.75
4 x 0.75
3G x 2.5
2x1
2 x 0.5
2 x 0.5
80HMA-M06
1
6
3
No
800 x 450 x 320
35
230-1-50
C32
M03
230-1-50
207-253
1.15
C6
3
C20
18
3G x 4
2 x 0.75
4 x 0.75
3G x 2.5
2x1
2 x 0.5
2 x 0.5
80HMA-T06
1
6
3
No
800 x 450 x 320
35
400-3-50
C16
M06
230-1-50
207-253
1.15
C6
6
C32
31
3G x 6
2 x 0.75
4 x 0.75
3G x 2.5
2x1
2 x 0.5
2 x 0.5
80HMA-T09
1
9
3
No
800 x 450 x 320
35
400-3-50
C20
T06
400-3-50
360-400
1.15
C6
6
C16
14
5G x 2.5
2 x 0.75
4 x 0.75
3G x 2.5
2x1
2 x 0.5
2 x 0.5
T09
400-3-50
360-400
1.15
C6
9
C20
18
5G x 4
2 x 0.75
4 x 0.75
3G x 2.5
2x1
2 x 0.5
2 x 0.5
Note: The heat pump data depends on the heat pump used.
Sound levels, indoor units
4
Sound power level
Sound pressure level
dB(A)
dB(A)
* The comfort module has no running parts.
0
0
Operating limits
Heat pump limits
Comfort module limits
Indoor temperature
Water temperature, cooling
Water temperature, heating
Depends on the heat pump selected
5-30°C
4-18°C
20-80°C
Pressure drop, comfort module
Pressure, dop, kPa
50
45
40
35
30
25
20
15
10
5
0
0
500
1000
1500
2000
0
0.14
0.28
0.42
0.56
2500
3000
3500
4000
4500
5000
0.69
0.83
0.97
1.11
1.25
1.39
Flow rate, l/h
Flow rate, l/s
Head pressure, comfort
module plus pump kit
35
70
30
60
Head pressure, kPa
Pressure, dop, kPa
Pressure drop, comfort
module plus pump kit
25
20
15
10
5
0
50
40
30
20
10
0
500
1000
1500
2000
2500
3000
3500
4000
4500
0
0.14
0.28
0.42
0.56
0.69
0.83
0.97
1.11
1.25
Flow rate, l/h
Flow rate, l/s
5000
1.39
The pump kit is required when the available heat pump
pressure is too low to cover the system pressure drop. The
water pump in the heat pump will then be used to irrigate
the comfort module buffer tank and the additional comfort
module pump is used to distribute the heat from the comfort
module buffer tank to the terminal units.
0
0
500
0
0.14
1000
0.28
1500
2000
2500
3000
3500
0.56
0.69
0.83
0.97
Flow rate, l/h
0.42
Flow rate, l/s
High speed
Medium speed
Low speed
5
Pressure drop, comfort module plus BPHE kit
100
90
80
70
60
50
40
30
20
10
0
With 16 kW BPHE kit
60
Pressure, dop, kPa
Pressure, dop, kPa
With 8 kW BPHE kit
0
500
1000
1500
2000
2500
50
40
30
20
10
0
3000
0
500
1000
1500
2000
Flow rate, l/h
0
0.14
0.28
0.42
Flow rate, l/s
2500
3000
3500
4000
4500
0.97
1.11
1.25
5000
Flow rate, l/h
0.56
0.69
0
0.83
0.14
0.28
0.42
0.56
0.69
0.83
Flow rate, l/s
1.39
Head pressure, comfort module plus BPHE kit
With 16 kW BPHE kit
70
70
60
60
Head pressure, kPa
Head pressure, kPa
With 8 kW BPHE kit
50
40
30
20
10
0
0
500
1000
1500
2000
2500
3000
Flow rate, l/h
0
0.14
0.28
0.42
0.56
0.69
0.83
50
40
30
20
10
0
0
500
0
0.14
1000
0.28
Flow rate, l/s
High speed
Medium speed
Low speed
The comfort module BPHE kit includes a heat exchanger
and a circulating pump. It creates two independent water
loops, one between heat pump and comfort module buffer
tank and the other between the comfort module and the
terminal units. If the heat pump is used for heating only
applications, this option allows limiting the use of antifreeze
protection between heat pump and comfort module.
6
1500
Flow rate, l/h
0.42
Flow rate, l/s
High speed
Medium speed
Low speed
2000
0.56
2500
0.69
Dimensions, comfort module Clearances, comfort module
30
30
70
Note: All dimensions are in millimetres.
7
Physical data, two-zone kit
Dimensions
Unit H x L x D
Packaging H x L x D
Unit weight
Gross weight
Hydronic data
Water connections
Operating water pressure
Maximum pressure
Hydronic components
Pump
Three-way valve
Collector volume
Draining valve
Outside air operating range, heating and cooling
mm
mm
kg
kg
485 x 450 x 330
565 x 530 x 410
22
27
in
kPa (bar)
kPa (bar)
1” male
100 (1)
300 (3)
l
Two water-cooled pumps, three speeds, 70 kPa static pressure
One modulating valve, 6.3 Kv, switching time (90°) 240 seconds, 230-V, 3-point SPDT actuator
1
√
See Comfort module
Electrical data, two-zone kit
Power supply
Voltage range
Power input
V-ph-Hz
V
W
Sound levels, two-zone kit
230-1-50
207-253
260
Sound power level
Sound pressure level*
dB(A)
dB(A)
Without comfort
module
44
30
* Measured at 2 m distance, in accordance with UNI EN ISO 3741.
With comfort
module
44
30
Available static pressure, two-zone kit
Zone with modulating valve
Zone without modulating valve
80
80
70
60
60
Pressure, kPa
70
Pressure, kPa
50
40
40
HI
HI
ME
ME
LO
30
LO
30
20
20
10
10
0
0
0
0
500
0.14
High water pump speed
Flow, l/h
Flow, l/s
Medium water pump speed
Low water pump speed
8
50
1 00 0
15 0 0
0
0.28
0.42
0
500
0.14
Flow, l/h
Flow, l/s
1 00 0
0.28
15 0 0
0.42
137
329
Dimensions (mm), two-zone kit
69
74
182
74
448
387
240
( 102 )
483
141
31
Clearances (mm), two-zone kit
Connected to the comfort module
Detached from the comfort module
30
30
30
30
70
30
30
70
9
Physical data, domestic hot water (DHW) module
Water tank size
Number of coils
Electric heater back-up
Voltage
Operating temperature range
Operating pressure DHW module
Operating pressure heat exchangers
Ambient operating temperature range
Storage temperature range
Lower heat exchanger
Upper heat exchanger
Diameter
Height
l
kW
V
°C
bar
bar
°C
°C
m2
m2
mm
mm
60STS 020E03
212
1
3.3, single-phase
230 ± 10%
5 to 95
0 to 10
0 to 6
5 to 45°C
-20 to +75°C
1.2
600
1215
60STD 020E03
212
2
3.3, single-phase
230 ± 10%
5 to 95
0 to 10
0 to 6
5 to 45°C
-20 to +75°C
1.2
0.5
600
1215
60STS 030E03
291
1
3.3, single-phase
230 ± 10%
5 to 95
0 to 10
0 to 6
5 to 45°C
-20 to +75°C
1.5
60STD 030E03
291
2
3.3, single-phase
230 ± 10%
5 to 95
0 to 10
0 to 6
5 to 45°C
-20 to +75°C
1.5
1.1
600
1615
600
1615
Electrical data, domestic hot water (DHW) module
Model
Maximum operating current
Power supply
Voltage range
A
V-ph-Hz
V
1.
2.
3.
4.
5.
6.
Main unit
Domestic hot water tank control box
Circuit breaker
Mains supply connecting cable
Booster heater activation cable
Temperature sensor cable
L
N
Earth
Live power supply
Neutral power supply
10
60ST-020/60ST-030
15
230-1-50
207-253
Cable type and size (4): H05VV-F
Cable type and size (5): FROH2R
Cable type and size (6): FROH2R
3G x 2.5 mm2
2 x 1 mm2
2 x 0.5 mm2
Dimensions (mm), domestic hot water (DHW) module
2
1
&
%
3
4
^
Legend
1 Water outlet (hot water)
2 Water outlet (hot water)
3 Anode connection
4 Connection for temperature sensor/pressure gauge
5 Connection for temperature sensor/pressure gauge
6 Connection
7 Electric heater (flange-mounted)
8 Fastening hole
9 Water inlet (cold water)
10 Lower coil outlet
11 Connection for temperature sensor/pressure gauge
12 Lower coil
13 Lower coil inlet
14 Upper coil outlet
15 Temperature sensor
16 Upper coil
17 Upper coil inlet
18 Control box
19 Cable holder
20 M6 nut earth
21 Insulation
22 Aesthetical cover
*
5
%
$
6
(
#
@
!
0
7
9
8
q
w
)
Typical installation diagrams, domestic hot water (DHW) module
System with solar panel and tanks
60STD 020E03 or 60STD 030E03
System without solar panel and tanks
60STS 020E03 or 60STS 030E03
h
8
7
8h
7
4
2
3
1
2
3
1
5
4 6
Legend
1 Water circuit
2 Check valve
3 Pressure reduction device
4 Expansion tank
5 Safety valve
6 Drain valve
7 Boiler
8 Thermostatic valve
5
4 6
11
Environmental
Management
Systems
Order
No.: 18405-20, 04.2012. Supersedes order No.: New.
Manufacturer reserves the right to change any product specifications without notice.
Manufactured by: Carrier SpA, Villasanta, Italy.
Printed in the European Union.