Brave Smyle - LC User manual

Add to my manuals
58 Pages

advertisement

Brave Smyle - LC User manual | Manualzz

Brave – Door Intercom

Brave Smyle - C

Brave Smyle - LC

Brave Smyle - C/C

User guide

Version 2.6

Dear customer

Congratulation to your purchase of “BRAVE SMYLE door intercom”. The

BRAVE Smyle door intercom is designed as universal project to be suitable for different installation on the field and brings more features and possibilities.

This manual is designed for Urmet 1129 panel in 4 models with 1 or 2 buttons:

Brave Smyle - C - Comfort model

Brave Smyle - C/C - Comfort model with analog camera

Brave Smyle - LC - Low cost model

Basic features of BRAVE door intercoms

SMYLE solution – surface installation only

IP 44 casing protection

LED cards lighting

Integrated analog color camera (C/C, LC/C)

1 (2*) relay with 8 different operational modes

 possibility to use electrical lock PSU for feeding the unit (C)

 elektronical loudness settings ( without neccessity open the unit)

 adjustable tones detection for REDIAL or Hanging Up

 integrated RTC ( realtimeclock) circuit – automatical DAY/NIGHT switching (C)

 programming by phone DTMF or by USB cable from PC**

24 digits length of number including

*

# Flash and Pause

(C/C, LC/C) – models only

* Comfort version only

** USB cabel is an option

Version of manual V2.6 22.10.2013

Alphatech spol. s r.o.

Jeremenkova 88

140 00 Praha 4

Tel/fax: 272103334 www.alphatech.cz

/ [email protected]

Content

1 BASIC DESCRIPTION ......................................................................................... 6

1.1

F EATURES ........................................................................................................ 6

1.2

T ERMINOLOGY ................................................................................................. 7

1.3

D IFFERENT M ODELS OF S MYLE B RAVE DOOR INTERCOM ................................ 8

1.4

M ODELS OF B RAVE DOOR INTERCOM ............................................................... 8

1.5

PCB S CHEMATICS ............................................................................................ 9

2 INSTALLATION ................................................................................................. 12

2.1

A SSEMBLY ..................................................................................................... 12

2.1.1

Assembly of Brave Smyle front panel ........................................................ 12

2.1.2

Assembly of cards backlighting................................................................. 13

2.1.3

Wall mounting of Brave Smyle .................................................................. 13

2.1.4

Replacing of cards backlighting after wall mounting ............................... 14

2.1.5

Cards exchange (name cards)................................................................... 14

2.2

C ONNECTION ................................................................................................. 15

2.2.1

Code relay (COSW) .................................................................................. 16

2.3

C AMERA ( /C VERSION ONLY ) ........................................................................ 18

2.4

A CCSSESORIES ............................................................................................... 19

2.4.1

Weather hood 19

2.4.2

TimeRelay 19

2.4.3

DistyBox 19

2.4.4

Power supply 12V ..................................................................................... 20

2.4.5

Programming cable USB .......................................................................... 20

2.4.6

BlackBox 20

3 DOOR INTERCOM SERVICE ......................................................................... 21

3.1

S IGNALLING OVERVIEW ................................................................................. 21

3.2

V ISITOR AT THE DOOR .................................................................................... 22

3.3

P ERSON INSIDE BUILDING ............................................................................... 24

3.3.1

Outgoing call 24

3.3.2

Incoming call 25

3.4

A COUSTIC PATH SETTING ............................................................................... 25

4 PARAMETRES PROGRAMMING .................................................................. 26

4.1

P ROGRAMMING BY PHONE ............................................................................. 26

4.1.1

Programming enter ................................................................................... 26

4.1.2

Parametres programming ......................................................................... 26

4.2

PC PROGRAMMING

– B RAVE S ET PROGRAMM ................................................ 27

5 DESCRIPRION OF PROGRAMMABLE PARAMETRES ............................ 28

5.1

D IRECT NUMBERS DIAL

MEMORIES .............................................................. 28

5.2

R ELAY ( S ) ....................................................................................................... 29

5.3

B ASIC PARAMETRES ....................................................................................... 34

5.4

T IME PARAMETRES ......................................................................................... 36

5.5

S YSTEM PARAMETRES .................................................................................... 39

5.6

H ANDS F REE PARAMETRES SETTING ............................................................... 42

5.7

T IME PROGRAMM

AUTOMATIC DAY/NIGHT SWITCHING (C) ..................... 45

5.8

D EFAULT SETTTING AND ERASING ................................................................. 47

5.9

P ROGRAMMING TERMINATION ....................................................................... 47

5.10

P ARAMETRES OVERVIEW ............................................................................... 48

6 TECHNICAL PARAMETRES .......................................................................... 52

6.1

E LEKTRICAL PARAMETRES ............................................................................. 52

6.2

M ECHANICAL DIMENSIONS ............................................................................ 52

7 TABLE FOR EASY PROGRAMMING ............................................................ 53

BRAVE

– user guide

5

6

1 BASIC DESCRIPTION

1.1 Features

 Voice communication is powered from telephone line only

 Tone (DTMF) and pulse dial

 Two 24digit numbers with each button (including *, #, Flash and Pause)

 DAY/NIGHT switching by DTMF code or automatically by integrated real time clocks - RTC, weekly schedule (C model)

 Possibility of the call extension by * or # choice

 Possibility to connect 1 or 2 (only C) independent locks for door opening

 8 different relays modes (for example: additional ring, progressive opening)

 Two codes for hanging up the unit by telephone

 Two codes for door opening by telephone for 1 pulse and two codes for

2 pulses

 3 x 6 codes for each relay (code by buttons at doors)

 Can be connected electrically secure lock on the first switch (serial activation code)

 Possible switched on hang up by press the same push button

 Possible switched on mode "Baby Call"

 Possible switched on suppress receive DTMF by microphone

 Possible switched on accoustic tick to the conversation for speech recognition

 Possible switched on accoustic signalization of close the relay

 Adjustable number of rings before pick up an incoming call

 Adjustable parameters of tone dial, length of Flash and Pause

 Adjustable parametres of acoustical signalization

 Adjustable parametres of tones detector

 Elektronical loudness settings ( without neccessity open the unit)

 Integrated analog colour camera with permanent or automatical operation /C

 Automatical camera lighting infra LED /C

 Possibility of powering by external PSU 12V (Siemens) /C (C)

 Easy settings of HW by DIP switch

 Factory settings (default) in different levels

 Programming by phone DTMF or by USB cable from PC

 Integrated heating for PCB

 Permanent cards lighting, switchable

 Ground output for better protection against static electricity

(C)

– comfort model only (Comfort)

/C - model with camera only

BRAVE

– user guide

1.2 Terminology

Telephone line analog (2 wires) is way of connection to public network

(PSTN line) or connection to PABX – telephone exchange at place of installation ( extension line)

Line picking up begin of call – same like OFF HOOK by handset

Line hanging up end of call – same like ON HOOK by handset

Dial

Incoming call

DTMF - tone dial. It is dial by 2 tones combination (dial also special character * and #. Use Flash loop interruption)

Pulse – dial by loop interruption (dial numbers only) connection between intercom and phone has been done by

Outgoing call dial from phone.The intercom picks up the call after preprogrammed number of rings. After picking up and password inserting you can programm the unit by phone. connection between intercom and phone has been done by dial from intercom, for example : by button pressing

Call establishing it is stage when call is picked up by called party. This stage is not signalled at analog line. It just stop ringing tone and

El.lock code

Code relay call starts. It is difficult identify just this moment. function for relay closing by dial digits combination from intercom buttons between Doorphone Brave and the electric lock can be connected code relay (COSW - CodeSwitch), which is code on the board relay (COSW).

External code Digits combination dial from intercom buttons for relay activation. External = dial by intercom buttons – out of building ( at place of door intercom installation)

Internal code located at the lock and lock activates only when is the same the specified serial combination of the Brave and set the

Digits combination dial from phone for relay activation

(DTMF). Internal = dial by phone – inside building ( phone connected to other PBX extension)

The manufacturer continuously improves the product firmware. The technology used allows you to upload to Brave the latest version of the firmware any time using a standard computer with BraveSet and USB cable. The latest version of the firmware is available at http://www.alphatech.cz

BRAVE

– user guide

7

1.3 Different Models of Smyle Brave door intercom

Brave door intercoms is designed as new generation of door intercom units reflects all experiences collected during last 10 years of succesfull sales of door enry solutions. Features and parametres are different for different models of intercom to provide best balance between price and usage value.

In this manual you will meet features and parametres marked by (C) which are specific for Brave Smyle (Comfort) model only and features and parametres marked (M) which are planned for modular model (in Smyle solution are not provided due mechanical solution)

Labelling of availability function :

Model LC (low cost) has all features except particularly marked

Model /C is version equiped by full colour analog camera

Model C (comfort) has special features marked by (C)

Model M (modular) has marked (M) – in mechanical Smyle solution is not produced! And it is mentioned in programming tables only which are same for all models.

1.4 Models of Brave door intercom

SMYLE models of Brave LC/C includes appropriate mother board with all connectable elements.

Brave Smyle - 01C Brave Smyle - 01C/C Brave Smyle

– 02C Brave Smyle – 2C/C

Brave Smyle - 01LC Brave Smyle

– 02LC

Models LC and C are different up mother board components. In model (LC) is missing:

Second relay

RTC real time clocks for automatic DAY/NIGHT switching

Models with camera /C have added:

Possibility of external powering (usable for relay modes 7 and 8)

 automatical / permanent lighting for camera (infra)

 switch off cards lighting

 disconnectable internal impedance for camera cable ending 75ohm

8 BRAVE

– user guide

1.5 PCB Schematics

All functional and connectional elements are marked by red rounded number at bellow picture. Explanation follow on next page.

Pict. 1 Brave Smyle mother board

(1) + (3) + (7) + (11) - version /C only relay 2 version (C) only

BRAVE

– user guide

9

1. Camera lighting - infra LED. It lights up space before camera when is active.

It is possible switch off (via. item 7) – version for camera only /C

2. Connector to PC connection via USB cable

3. Analog colour camera – version with camera /C only

4. Speaker connection

5. Microphone connection (caution on polarity)

6. DIP switch in all models:

1 = Service, usage – when programming password is forgotton. Incoming call is going directly to programming mode where you can set new password.

2 = Heating

– switch ON integrated heating of mother board to increase resistance against condensation water during changes of temperature

7. DIP switch position in versions (C) and /C:

3 = external power supply

4 = external power supply – switching 3 and 4 simultaneously. The powering is used from screw 12V (11) due following reasons:

- using relay mode 7 or 8 – tpermanent switching ON/OFF is possible only with external power supply. Dont forget setup parametr 64.

- Connection of door intercom to certain type of PBX which has problems with current consumption on its extensions during start (Siemens).

5 = Camera lighting up (switch ON/OFF lighting of space before camera via infra

LED)

6 = Cards lighting (switch ON/OFF Leds backlighting for cards beside button)

7 = Activate permanent camera operation. In default camera is active only when door intercom is active.

8 = Allows connect 75ohm to camera output - impedance

8. Analog telephone line (not depends on polarity)

9. Grounding – connection to ground of static electricity protection – protects electronic of door intercom as same as PBX

10. Relays are galvanically isolated - max. 48V, max. 1,5A model (C) has 2 relays model (LC) has 1 relay only on switch 1 is available relay function code (COSW - CodeSwitch) (see

page16)

11. Camera output - PAL video 1V / 75ohm. For distance longer than 25m we recommend coax cable. For other installation UTP cable is also available.

/C

model only

12. 12V power supply: - relays control

- mother board heating

- cards backlighting

- camera powering and infra LED camera lighting up

- external powering of unit (DIP 3 and 4)

The power supply might be AC as same as DC, not depends on polarity, max consumption 250mA from 12V.

The power supply might be used also for electrical lock powering. Then we recommend power supply 12V/1A.

10 BRAVE

– user guide

You can also use 24V DC power supply. It is useful mainly at installations where power supply is already installed and it is used for sliding doors,

RFID, etc.. The heating has control element to restrict power.

The remaining components are designed for voltage up 24V DC!!!

It not depends on polarity.

BRAVE

– user guide

11

2 Installation

2.1 Assembly

2.1.1 Assembly of Brave Smyle front panel

12 BRAVE

– user guide

2.1.2 Assembly of cards backlighting

2.1.3 Wall mounting of Brave Smyle

Make the mounting by attached pack with screws and plug (drill 5mm).

BRAVE

– user guide

13

2.1.4 Replacing of cards backlighting after wall mounting

2.1.5 Cards exchange (name cards)

Every button has own card ( label) holded by plastic flag ( via picture).

You can print out paper labels from special Excel file (downloadable on www.alphatech.cz or ).

14 BRAVE

– user guide

2.2 Connection

The basic functionality of intercom (voice communication) needs

connection of telephone line only - LINE (8) on .Pict. 1 Brave Smyle. The line

is connected by 2 wires (a,b) and in stand by has usually voltage 24V - 60V, short circuit current 20mA - 60mA. When line is OFF HOOK the line voltage is

7V - 10V.

Line connection Brave Smyle intercom announce by sound signal

(Reset) ♫ (capture 3.1 page.21) when is disconnected from line certain time.

Brave Smyle is analog intercom designed for connection to analog line( PSTN line or PBX analog extension) it means line where works ordinary analog phone.

It works regardless to line polarity and in range mentioned in technical

parametres (capture 6).

Paralel connection – we not recommend! Paralell connection with other analog phone or other door intercom is not recommended! We also not recommend use special devices switching the line ( inteligent couplers, adapters, etc..).

When model of Brave Smyle is with camera /C then on screw CAM

(11) on Pict. 1. connect cable for video transmission. Up to 25m you can use

one free pair of UTP cable. For longer distances you have to use coax cable

Pict. 1. Camera mode you setup by DIP switch (capture 1.5) and camera is

either activated automatically (when intercom is active) or is permanently ON

(DIP 7). Camera lighting up by infra LED is either active with camera (DIP 5) or you can permanently switch OFF. Due DIP 8 you can paralelly connect to video output impedance 75ohm

12V power supply (12) on Pict. 1 must be connected for mother board

heating, cards backlighting, camera powering inludes infra LEDs and for relays control. The power supply might be AC and also DC, not depends on polarity.

From 12V is max consumption 250mA. Power supply might be used also for electrical lock powering. Then we recommend power supply 12V/1A. You can also use 24V DC power supply. It is useful mainly at installations where power supply is already installed and it is used for sliding doors, RFID, etc..

You can use only 24DC power supply not AC!!! Not depends on polarity.

Relays (10) on Pict. 1 have many possibilities in practise usage. The

examples (drawings) are mentioned on Pict. 2. 12V power supply must be

connected for correct operation. The intercom unit has galvanically isolated all important parts. Telephone line is isolated from power supply and relays contacts are also galvanically isolated from other intercom electronic parts.

In any case must not be activated directly main voltage 120V or

230V !!! When you need control main devices please use contactors ( power

relays) as it is on Pict. 2 example (6) .

BRAVE

– user guide

15

Relays connection examples are mentiond on following page. It is not all of them but give you an idea how should be connected individual circuits (red rings with numbers = example numbers).

1. Basic connection - 2 elektrical locks and possibility independently control two doors. (relay mode 1 and 2 m=1) or progressive door opening (relay mode 2 m=5 - version (C) only.

2. Two power supply – possibility to use independently two power supply One for Brave Smyle and second for electrical locks. Second electrical lock is connected inversaly (fire emergency exit).

3. Combination of doors with electrical lock and sliding gate at fencing.

4. Extending of previous example (3) about second doors with progressive opening (this feature is setup in TimeRelay - optional modul)

5. Combination of electrical lock and additional ring. Relay of additional ring might be in mode m=4 (from each button is activated for preprogrammed time) or in mode m=6 (it is activated from one presetup button for preprogrammed time)

6. Lighting activation m=3 (for example: way to building ) and control of for example: heating up DAY/NIGHT mode m=8 ( (C) version only - RTC circuit). External power supply required (DIP 3 and 4) /C version only.

Further is neccessary use contactor (Brave Smyle must not activate

230V!).

2.2.1 Code relay (COSW)

For the first switch is available function code relay (COSW CodeSwitch).

It serves primarily to secure transmission of information by switching the electric lock. When using this function is not possible connecting or disconnecting the voltage at the terminals to lock this lock activated. Activation is performed only when positive result compared serial information transmitted between Brave and the board code relay

Brave is set in several codes to activate the relay code.

Relay can be activated codes for one or two impulses can differentiate activated from the phone (DTMF) or from keys

(keyboard). The last option is the activation code in another mode switch than the lock.

The code information is 8 bits, but the code is 4 bits with security 4 bits which is total of 8 bits. Practically, this is performed so that after activation the switch is first transmits the serial code, and if they agree, so code relay connects the electric lock.

The code relays can be connected in parallel to increase the number of switches, but can never combine connections electric lock and the code relay parallel!

16 BRAVE

– user guide

Pict. 2 Examples of relay connection

BRAVE

– user guide

17

2.3 Camera ( /C version only)

Technical parametres:

- videonorm:

- sensor:

- picture area:

PAL-CCIR

CMOS 1/3''

5,78x4,19mm

- resolution:

- video output:

628x582pixel 380 rows

1V p-p/75 ohm

- automatic profit control: 18dB

- minimal lighting: 3LUX

- automatic lens shutter: 1/60-1/15000sekund

- camera view: 50st.

18

- zoom: manually

BRAVE

– user guide

2.4 Accssesories

2.4.1 Weather hood

It increases intercom protection during raining. It is fixed by adhesive labels from sides.

2.4.2 TimeRelay

Time relay allows expansion of relays functionality. It is individual product and detail manual you find on our websites www.alphatech.cz

2.4.3 DistyBox

This optional modul is plastic box allows you to connect analog unit (phone, intercom) into wireless system DECT –

GAP (for example Siemens line GigaSet,

TopCom line Butler etc.). DistyBox is suitable for intercom connection when are cables not available. You just registrate intercom as handset to DECT base station. All features of intercom are kept.

Important: DECT base station must support

DTMF transmission between each handsets

(relay activation feature).

BRAVE

– user guide

19

2.4.4 Power supply 12V

As standard we provide for Brave Smyle intercom AC power supply 12V/1A . It is not part of unit packaging. It must be ordered individualy. More info about electrical locks and power supply on www.alphatech.cz.

2.4.5 Programming cable USB

USB cable is not part of packaging. It must be ordered individualy. USB drivers are downloadable on www.alphatech.cz

2.4.6 BlackBox

BlackBox is DTMF modem useful for remote programming from PC. Via

BraveSet programm you can remotely setup all parametres of Brave Smyle intercom.

3

20 BRAVE

– user guide

3 Door intercom service

Functionality of Brave Smyle door inercom is adjustable by parametres

settings (via. Programming parametres capture page 26).

3.1 Signalling overview

The Brave Smyle door intercom signalling acoustically stages which are happening during operation. Samples of acoustical sounds you can play in

BraveSet ( PC programm).

Stage Tones Tone frequency

Line pick up ( OFF HOOK) type 1

Line hang up ( ON HOOK) type1

Line pick up ( OFF HOOK) type 2

Line hang up ( ON HOOK) type2

Command confirmation by phone

Alerting (knocking) into call

Call ending alert

Relay activation signal

Programming enter by phone

Programming by phone

Parametr confirmation

Programming enter by PC

Line connection (Reset)

Error (generally all incorrects)

–▄■▄■▀–

–▀■▄■▄–

–▄■▀–

–▀■▄–

––█––

─┴─┴─

–■–■–■–

─▒▒▒▒▒▒─

–▄■▀–

––▓–▓–––––

––█––

–▄■▀–

–■–▄–■–

–■–■–■–■–■–■–

980-1333-1650

1650-1333-980

800-1067-1200-1333

1333-1200-1067-800

800

1333

Modulovaný

980-1067-1180

Modulov aný

800

980-1067-1180

1850-1067-1850

800

Memory empty (no number programmed) –▄■▄■▄■▄■– 1300-2100

During problems identification is very good when you know the tones. It helps you monitor how door intercom works and where from comes the problem.

The signalling might be switch of in a few levels (parametres 61,62,63 and 65).

BRAVE

– user guide

21

3.2 Visitor at the door

Door intercom buttons have signs (cards) like usual ring buttons. Visitor find desired name ( for example“Scott") and push it. The Brave intercom pick up the line and "play" tone line pick up (when is not switch off by par.62) and dial phone number saved under the button (parametr 1 or 2 up door intercom mode).

From Brave intercom speaker you hear ringing tone and phone of Mr. Scott is ringing. As soon as Mr. Scott pick up ringing phone he can talk to visitor at the door. When is electrical lock connected to Brave intercom then Mr. Scott can open the door for visitor by dial DTMF code on his phone. When Mr. Scott hang up the phone then Brave intercom hangs up as well after busy tone detection.

When call duration is longer then setup limit (parametr 52) the 10sec before hang up Brave intercom sends alerting tone of call ending. Mr. Scott can dial * or # up setting (parametr 42) to prolong the call about the time setup by

parametr 52.

Dialled number from Brave intercom is different up dial mode setup in the unit by (parametr 47):

- Day/Night mode = when intercom is in DAY mode then number setup by

parametru 1 is dialled. When intercom is in NIGHT mode then always dial number setup by parametr 2. Manual intercom modes switching is setup by parametres 45,46. In version (C) you can switch DAY/NIGHT mode automatically. Selection of dialled number saved under the button is control by time up table (parametry 00-06).

- 2 groups numbers mode = first button push – always dial number setup by parametr 1. When the same button is pushed or 10seconds after dial busy tone is detected, or setup number of rings is out (parametr 56) the door intercom dial number from second group setup by (parametr 2). When you push the same button again you will dial again number from first group etc.

……(when after dial number from second group busy tone is detected the repeating is finished)

When visitor push the button after line is picked up the door intercom hangs up for time setup by parametr 54 and then picks up the line and dial new number ( second push number). The number dialling is either by tone dial

(DTMF) or pulse dial up setting by parametr 41. There is one more option and it is line hangs up by again pushing of same button (parametr 4*).

You can control relay(s) by door intercom buttons (code lock). When visitor push buttons in order which match to setup code (parametr 32-34) and time between each button press is not longer than setup by (parametr 53) then door intercom picks up and activate appropriate relay (when relay setup is mode m=1 or m=5) for time setup by parametr 37 eventually.39,30. Then hangs up.

The relay (up control code) can activate one pulse or two pulses with time

between each pulse setup by parametr 30 via. Tab. 1.

22 BRAVE

– user guide

mode m = 1 (parametr 3111 and 3121)

Action Note Parametr Relay

Evaluation of correct external code from buttons

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settins

DAY/NIGHT

3211-3215

3311-3315

3411-3415

3221-3225

3321-3325

3421-3425

321*

331*

341*

322*

332*

342*

Internal code from phone

351

You can dial 1 or 2 numbers of code

2digits code is default

You can shorter it by using * on first digit of code during programming

352

361

362

Mode m = 5 (parametr 3125)

Action Note

Evaluation of correct external code from buttons

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settings

DAY/NIGHT

Internal code from phone You can dial 1 or 2 numbers of code

2digits code is default

You can shorter it by using * on first digit of code during programming

Parametr Relay

3211-3215

3311-3315

3411-3415

3221-3225

3321-3325

3421-3425

321*

331*

341*

322*

332*

342*

351

352

361

362

BRAVE

– user guide

23

mode m = 4

Action

Button push

Note

Any button different from

311* or 312*

Parametr

3114

3124

Relay

3114

Button setup by 311* or

312*

3124

Mode m = 6

Action

Button push

Note

Any button different from

311* or 312*

Parametr

3116

3126

Relay

-

-

3116

Button setup by 311* or

312*

3126

Poznámka: t1 – time activation 1 of relay (parametr 371) t2 – time between pulses 1 of relay (parametr 301) t3 – time between activation 1 and 2 relay (parametr 39) t4

– time activation 2 of relay (parametr 372) t5 – time between pulses 1 of relay (parametr 302)

Tab. 1 Table of relay(s) control

3.3 Person inside building

By person inside building we mean person in telephone connection with

Brave intercom , for example Mr. Scott.

3.3.1 Outgoing call

Outgoing call is a call from door intercom (generated by visitor). After door intercom dial is ringing a phone inside the building. When you pick up the phone you can talk to visitor. By code dialling you can activate the relay (parametr 35) when relay is setup in mode m=1 or m=5. You also can switch operation mode

DAY/NIGHT (parametr 45,46) and hang up (parametr 43). Door intercom sends

10sec before call ending (parametr 52) alerting tone and you can prolong the call by dialling special character from phone (parametr 42). By phone hanging up the call is ended (PBX generates busy tone into the line which is detected and door intercom hangs up). There is one more option which is hang up the line by again push of the same button (parametr 4*).

24 BRAVE

– user guide

3.3.2 Incoming call

Incoming call is a call into door intercom (generated by person inside the building). After dialling extension number where is connected door intercom the door interocm line is ringing. After setup number of rings the door intercom picks up (parametr 51) and you can talk. Other

possibilities are the same like in case of outgoing call (capture 3.3.1).

First exception is first 10sec where you can dial "# and service password"

(parametr 44). By this you enter programming mode of door intercom.

Second exception is when DIP1 is switch to position ( "SERVIS" ). Then you enter programming mode directly without dialling service password.

Last exception is relay(s) control (parametr 381 and 382). You can by programming prohibit to control relay(s) from incoming call .

3.4 Acoustic path setting

The principle of setting acoustic paths:

Here we have three parameters 71.72 and 73 Using the interaction of these parameters can be set to sound in different conditions.

1. quiet environment parameters 71,72,73 are set to 7

2. environment where is a strong ambient noise at the communicator and quiet environment at the phone. Here is both necessary to reduce the microphone gain (parameter 72 = 1-3) and also change the ratio of the parameters 71/73 way 73 enlarge the the parameter (parameter 73 = 11-15) and 71 parameter smaller value (71 = 2-4)

3. environment where is a strong ambient noise at the phone and quiet environment at the communicator. Here we leave the parameter value of 72

= 7 and 73 and 71 parameters set as follows - parameter71 = 11 to 14 and

73 = 2 to 4

The principle of settin parameters is - signal from the microphone is amplified by the sum of parameters 72+71 = volume of microphone and signal to the speaker is amplified by the sum of parameters 71+73 = volume of speaker. To switch the direction of the ratio is evaluated parameters (threshold) 73/72.

- If parameter 72 is greater than the parameter 73, thus favoring the direction from the microphone. We choose when the direction to the phone is interrupted.

- If parameter 73 greater than parameter 72, thus favored direction to the speaker. We choose this if the interrupted sound in the speaker of communicator.

BRAVE

– user guide

25

4 Parametres programming

4.1 Programming by phone

4.1.1 Programming enter

You can enter programming mode by following ways:

1. password – incoming call only! – pick up the phone and dial phone number where is door intercom connected (either extension number when door intercom is connected to PBX or PSTN line number of building where is door intercom installed and let operator connect you to appropriate door intercom extension) . Door intercom picks up (you hear pick up acoustic tone

– via. capture 3.1 page.21) and you have to dial within 10 sec

#xxxx, when xxxx is service passsword to enter programming mode

(default xxxx=0000) . When all is correct you hear acoustic tone of programming mode enter and after a while you hear programming tone

(via. capture 3.1 page.21).

2. switch "SERVIS" – incoming call only! – the connection you establish the same way like in item 1. but only when DIP1 switch is in position

"on". Then door intercom after picks up going directly into programming

mode without neccessity to insert service password. (via. capture 3.1 page.21).

4.1.2 Parametres programming

Stand by stage of programming is announced by programming tone into which door intercom always returns after time out (5sec) whenever you started to programm.

There are two kind of parametres you can programm. First are parametres with fix length – Most of parametres are those. The parametr is saved immediatelly after inserting mandatory length – you hear confirmation tone.

Second are parametres with variable length (parametr 1, 2,32,33,34). Saving and confirmation of those parametres is made after 5 seconds inserting last dial.

There is one case when those parametres are saved immediately and it is filling up maximal number of characters (numbers) – at parametr 1 and 2 it is 24,

parametr 32,33,34 it is 6.

When during programming insert number(character) which is unacceptable then door intercom sends error tone. The parametr is not saved even changed. Door intercom returns to stand by and you can start again parametr programming of programm other parametr.

When you enter programming mode and do not make any dialling for

30seconds the door intercom will hang up. After each dialled DTMF tone the time is prolonged about 30seconds. You can finish programming mode also by dialling parametr 9.

26 BRAVE

– user guide

4.2 PC programming – BraveSet programm

For PC programming of door intercom you have to purchase special

USB cable USB-KAB and programm BraveSet ( free on every CD). Then you have to connect door intercom into the line or at version /C or (C) switched ON and connected power supply 12V - DIP3 and 4.

Procedure:

- Connect telephone line into door intercom or at version /C and (C) you can use external power supply 12V (DIP 3,4)

- Connect special USB cable to PC USB socket . Door interocm picks up the line within 3 seconds and play tone of programming enter (via. capture

capture 3.1 page.21).

- Run programm BraveSet. Door intercom is in programming mode during all the time when programm BraveSet is running. The door intercom stays pasive until moment of USB cable disconnection. When you loose connection please disconnect USB cable from door intercom and connect it again – door intercom picks up.

- Correct connection PC with BraveSet programm is indicated by reading firmware version from door intercom ( visible in bar) as same as reading the time ( shown in left top corner). When you have version (LC) then time is 0 because LC version doesnt includes RTC circuit.

For easy orientation are parametres in BraveSet programm marked by the same codes like codes for programming by phone.

Details about setting you will find in programm HELP and on website www.alphatech.cz

.

USB cable is special cable with galvanical isolation and with 3V convertor. The galvanical isolation is neccessary because telephone line must not be grounded and PC´s are usually grounded.

BRAVE

– user guide

27

5 Descriprion of programmable parametres

Parametres always starts by fix, mandatory part ( adress) and variable part – it is your dial. Range and explanation is always under each table . All is dial like it is written in table. You dont dial any confirmation character. After savings into memory you get back confirmation tone. When dialled value is incorrect you get immediatelly error tone.

5.1 Direct numbers dial – memories

Parametr Value description

1 tt nn… Number nn under button tt

tt – button number (memory), always has 2 digits [01-99]

nn – phone number up 24 digits which you desire to save. For saving further characters use assignments mentioned in table.

Numbers saved in parametr 1 are numbers of first

group, or numbers of DAY mode.

Default settings doesnt erase as same as changed those saved numbers.

Default

- description dial

0 - 9

#

*

Flash

Pause

0 - 9

#

**

* #

* 0

Parametr Value Description Default

2 tt nn… číslo nn pod tlačítkem tt -

tt – button number (memory), always has 2 digits [01-99] nn – phone number up 24 digits which you desire to save. For saving further characters use description Dial assignments mentioned in table. 0 - 9 0 - 9

Numbers saved in parametr 1 are numbers of second # #

group, or numbers of NIGHT mode.

Default settings doesnt erase as same as changed those

*

Flash

**

* # saved numbers. Pause * 0

Note: switching DAY/NIGHT mode stays in door intercom even after line disconnection and version (C) this mode switch up current time (when this feature is activated - parametr 084)

Note: at version Brave Smyle - C and Brave Smyle - LC are available max. 2 buttons - tt=01-02

28 BRAVE

– user guide

Settings examples:

1. first button should dial at DAY number 358 and in NIGHT 0_603441296 , you programm it - 101358 and wait for

♫, next 2010 *0 603441296 and wait for ♫

2. second button should dial at DAY and NIGHT 123#1*2Flash3, you programm

102123#1 ** 2 *# 3 and wait for ♫, next 202123#1 ** 2 *# 3 and wait for ♫

Note. When you dont use mode of 2 group numbers or DAY/NIGHT mode we recommend setup DAY/NIGHT mode (parametr 47) and next setup same code for

DAY/NIGHT switching (parametry 45 and 46). You provide by this that door intercom will be always in DAY mode and then you programm numbers for DAY mode only

(parametr 1).

5.2 Relay(s)

Parametr Value Description Deafault

31 r m relay r works in mode m (1-8) 11 21 r – relay number [1-2]

m – relay mode [1-8 for r=1 is not mode m=5]

modes m=1,4,5,6 are detaily descriped in Tab. 1. on page 24

m=1 mode relay – activated by command (internal code) or password (external code) 1 pulse for time t1/t4 (using for electrical locks) or 2 pulses when is activated for time t1/t4, open for time t2/t5 and close for time t1/t4 (sliding door opening)

m=2 closed for time of line OFF HOOK (camera) – close when door intercom picks up and open by hanging up

m=3 closed for time of line OFF HOOK and more for time t1/t4 after hang up

(lighting) – closed when door intercom picks up and stays closed for time t1/t4 after door intercom hangs up (for this time line is busy, at version /C and C is after switching DIP 3,4 and settings parametr 64 for time t1/t4 line hanged up)

m=4 mode button – closed when any button is pushed and open after time t1/t4 (usage for example: connection external bell)

m=5 mode progressive opening – you can setup into this mode relay 2 only because relay 1 will be setup automatically into mode m=1. By command

(internal code) or password (external code) is activated relay 1 for time t1, then is running time t3 before closing relay 2. Then is relay 2 activated for time t4 and then door intercom hangs up. When dialled command or password match to 2 pulses then in sequence will appear two pulses

separated by time t2/t5. Explained in Tab. 1

Note. The command or password for relay 1start whole sequence.When you use command or password for relay 2 then you control relay 2 only the same like in mode m=1.

m=6 closed up pushed button (setup in parametr 31r*). Due this you can select

one button for every relay its pushing activate appropriate relay for time t1/t4. This mode serves as substitution of ring bell connected to Brave system.

BRAVE

– user guide

29

m=7 permanent closing / opening – usable at versions /C and (C) only, if switching (DIP 3,4)+par.64. By command for pulse 1 is closed and for pulses2 is opened. This stage stays in door intercom even after power/line disconnection. This mode you can use for potting, glasshouse opening, heating activation etc.. m=8 activated up DAY/NIGHT mode settings - usable at versions /C and (C) only, if switching (DIP 3,4)+par.64. Version /C allows copying manual

DAY/NIGHT switching only. Version (C) allows copying setting from week table switching time (when is activated - parametr 084) and then you can use for example for heating control etc…

Parametr Value Description Default

31 r* tt

(01-99) r – relay number [1-2]

tt – button number (memory), always has 2 digits [01-99]

This parametr is for relay mode m=6 only. Value of tt designate from which button start closing for time t1/t4 of relay r.

Parametr Value Description Default

32

33

34 rp hh... rp hh... rp hh...

In mode DAY + NIGHT password hh... for relay r, in order p=1-5, for 1 pulse and p=* for 2 pulses (00-999999)

In mode DAY password hh... for relay r, in order p=1-5, for 1 pulse and p=* for 2 pulses (00-999999)

In mode NIGHT password hh... for relay r, in order p=1-5, for 1 pulse and p=* for 2 pulses (00-999999)

-

-

- r

p

p

– relay number [1-2]

– order [1 - 5] for 1 pulse. 5 passswords (external codes) from door intercom buttons (external code of codelock)

– order = *, then you can insert just one code (external code) for closing by 2 pulses hh... – password (external code) for relay closing from buttons [2 to 6 digits].

Tlačítka 1 - 10 are programmable as numbers 1-0.

Totally 3 x 12 passwords. Controlled by settings DAY/NIGHT.

Combination is inserting by door intercom buttons .

Relay closing is influenced by setup relay mode and switching DAY/NIGHT. When is setup mode 2 groups

of numbers the door intercom is permanently in mode DAY.

You have to keep certain rules for password dialling:

 First button of password select from at least used button for direct dialling (-prolong dial time)

30 BRAVE

– user guide

 Caution on numbers identity of password. When one password includes other, for example:password for relay1 is 1234 and for relay 2 12345, then always after pushing button 4 relay 1 will be activated and relay 2 wont be never acivated. When you select password for relay 2 234, then after button 4 pushing both relays will be activated.

Note1. switching to DAY/NIGHT mode stays setup in door intercom even after power

(line) disconnection. At version (C), when is activated, then DAY/NIGHT switching is done up time and week table.

Note2.

when you insert parametres 32,33,34 do not use character # and * because you cant select them from button panel. Number 0 represents button 10.

Parametr Value Description Default

35 r aa command aa from phone for relay activating

r 1 pulse (00-99,*0-*9)

155 266 r – relay number [1-2]

aa – command (internal code) from phone for relay activation [2 digits] / 1

For both relays you can setup the same command (internal code) then both relays are activated simultaneously. It is profitable to setup the same command for relay activation as same as door intercom hang up (parametr 43) aa=bb.

/ 1 – command has always 2 digits but when you want control relay by 1 digit only ( from keypad of phone) then you have possibility to programm " *a " where

a is one number only which activate the relay (star represents empty character and must be on first digit position).

Example: 1 relay activated by internal code 48 - dial 35148

2 relay activated by internal code 8 - dial 352*8

By dialling on phone 8 you activate relay 2 by dialling 48 you activate both relays

Parametr Value

BRAVE

– user guide

Description Default

36 r cc command aa from phone for relay activation

r 2 pulses (00-99,*0-*9)

150 260 r – relay number [1-2]

cc – command (internal code) from phone for relay activation [2 digits] / 1

For both relays you can setup the same command (internal code) then both relays are activated simultaneously.

/ 1 – command has always 2 digits but when you want control relay by 1 digit only ( from keypad of phone) then you have possibility to programm " *a " where

a is one number only which activate the relay (star represents empty character and must be on first digit position).

Activation relay 2 pulses is suitable for example: at sliding gate which this way can also substitute wicket for person entrance.

31

Example: command to activate relay1 with 1 pulse *8, command to hang up *8 and command for activation relay2 with 2 pulses *9.

Dial: 352*8 ♫ , 432*8 ♫ , 362*9 ♫.

You are in communication with door intercom unit. Dial command for open sliding gate 9.

First pulse starts sliding the gate and second pulse stop it. The size of spot for person entrance is according time between each pulses (parametr 30). After person etnering you dial 8. The door intercom makes one pulse and hang up. Sliding gate is closing.

Parametr Value Description Default

37 r ss

(00-99) r – relay number [1-2]

ss – time t1 / t4 for which is relay closed 1 / 2 [2 digits 00-99], where time 00 means 0,5sec

Parametr Value Description Default

38 r p

Control relay r during incoming call

(0/1)

11 21 r – relay number [1-2]

p – parametr which says permitted p=1 or forbidden p=0 control relay during incoming call

To prohibit control of relay during incoming call has a sense for example by relay2 in mode 1 by which you control sliding gate opening where door intercom open the gate and after car passing the gate is closed. Then control by phone could make unwillingly permanent gate opening.

Parametr Value Description Default

39 xx

time xx [sec] between activation relay 1 and 2 in mode m=5 - time t3

(01-99)

10

xx – time t3 between activation relay 1 and 2 when mode m=5 is setup

(progressive opening) [2 digits 00-99] ], when time 00 means 0,5sec

Parametr Value Description Default

30 r zz time zz [sec] between pulses when is closing for 2 pulses relay r - time t2/t5

(00-99)

105 205 r – relay number [1-2]

zz – time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits

00-99], where 00 means 0,5sec

32 BRAVE

– user guide

Parametr Value Description Default

3#0 p

p = 1 enabled / disabled p = 0 connection code relay COSW (0/1)

0

p – turns on transmission serial code to activate the first switch.

CAUTION - at activation this function never connect to the circuit electric lock without board COSW - code relay - threatens to destroy the relay in Brave communicator!

The following codes may be the same or different for the resolution switching on multiple parallel connected relay code.

Parametr Value Description Default

3#1 abcd activation code 1 pulse from buttons

(0000-1111)

0000 abcd – Brave sends a serial code for the code relay (COSW) after evaluation code from keys (keyboard) namely for 1 pulse

Parametr Value Description Default

3#2 abcd activation code 1 pulse from phone

(0000-1111)

0000 abcd – Brave sends a serial code for the code relay (COSW) after evaluation code from telephone (DTMF) namely for 1 pulse

Parametr Value Description Default

3#3 abcd activation code 2 pulses from buttons

(0000-1111)

0000 abcd – Brave sends a serial code for the code relay (COSW) after evaluation code from keys (keyboard) namely for 2 pulses

Parametr Value Description Default

3#4 abcd activation code 2 pulses from phone

(0000-1111)

0000 abcd – Brave sends a serial code for the code relay (COSW) after evaluation code from telephone (DTMF) namely for 2 pulses

Parametr Value Description Default

3#5 abcd activation code from other modes of switch

(0000-1111)

0000 abcd – Brave sends a serial code for the code relay (COSW) after evaluation code from other modes m switch 1

BRAVE

– user guide

33

5.3 Basic parametres

Parametr Value Description

41 v Dial type v – tone / pulse (0/1) v – dial type v=0 is DTMF tone dial, v=1 pulse dial

Parametr Value Description

Default

0

Default

42 z Character to prolong the call (* / #) * z – character to prolong the call * or # (10sec before call termination door intercom sends notification then you can prolong the call)

Parametr Value Description Default

43 g bb

Command to hang up door intercom by phone

(00-99,*0-*9)

155 266 g – command order [1-2] (they are two to be possibility hang up door intercom when each relay is used)

bb – command to hang up door intercom by phone [2 digits] / 1

It is profitable setup the same command to hang up door intercom as same as activate relay (parametr 35,36) aa=bb or aa=cc

/ 1 – command has always 2 digits but if you want use 1 digit then you have possibility insert " *a " where a is just one number which activate the relay (star represents empty character and must be on first position). (Example at parametres

35,36)

Parametr Value Description Default

44 xxxx Service password (0000-9999) xxxx – service password to enter programming by phone (DTMF)

0000

34 BRAVE

– user guide

Parametr Value Description Default

45

46 dd nn

Command to switch into DAY mode

(00-99,*0-*9)

Command to switch into NIGHT mode

(0099,*0-*9)

11

10

dd – command to switch into DAY mode [2 digits] / 1

nn – command to switch into NIGHT mode [2 digits] / 1

/ 1 - command has always 2 digits but if you want use 1 digit then you have possibility insert " *a " where a is just one number which switch DAY/NIGHT mode (star represents empty character and must be on first position).

Note. Switching into DAY or NIGHT mode stays setup even after power (line) disconnection from door intercom

Parametr Value Description Default

47 e Door intercom dial mode (0/1) 1 e – dial numbers mode e=0 dial numbers from first and second group, e=1 numbers are dialled up DAY/NIGHT mode in door intercom

CAUTION !! setting of this parametr has a big influence to numbers dialling

Parametr Value Description Default

4* k

Feature of line hanging up by again push of the same button (0/1)

1 k – line hanging up by push of same button:

k=0 feature is switch off

k=1 again button push hang up the line

CAUTION !! setting of this parametr has a big influence to numbers dialling

BRAVE

– user guide

35

5.4 Time parametres

Parametr Value Description Default

51 q

Number of rings before door intercom picks up incoming call (1-9)

2 q – number of incoming call rings . Door intercom picks up between rings and

2 sec after detection of q – th rings. Number is adjustable from 1 to 9.

Parametr Value Description Default

52 d Maximal call duration (0-9,*,#) d – maximal time for which door intercom is OFF HOOK.

This time you can prolong by dial character during a call by phone (* or # - parametr 42 ). Setting of time is up table.

2 time[min] Dial

0,5

1 - 9

15

30

0

1 - 9

*

#

Parametr Value Description Default

53 w Time between button push (1-9) 2 w – maximal time [sec] between button push [range 1-9]

normal buttons

- relay activation – when time between push of 2 following buttons is longer than time w then code is evaluated incorrectly.

- Number dial – when button which we push is first number in password for relay activation then dial is delayed about this time w

36 BRAVE

– user guide

Parametr Value Description Default

54 z Hanging up time during REDIAL (1-5) 2 z – time [sec] for which door intercom hangs up before pick up for REDIAL

(button push during call, busy tone detection) [range 1-5]

Parametr Value Description Default

55 z Time before start dialling (1-5) 1 z – time [sec] after door intercom picks up and before start dialling [range 1-5].

This time is different for every PBX but usually all PBXs accepts dial within 2 seconds after line is picked up.

Parametr Value Description Default

56 hh Number of rings before hang up (04-99) 12 h – after dial termination calculate number of CRT (control ring tones). When number is higher than hh then hang up [range 04-99]. Dial is repeated in case of 2 groups mode.

Parametr Value Description Default

500 x Middle frequency of tones detector (1-0) 3 (375-475Hz)

501 y Number of busy tones (2-0) 4

502 z Time of permanent tone duration (1-5) 3 (3s)

x middle frequency of tones detector – is suitable when PBX signalling is unusual: frequency

[Hz] x - dial

275-375 1

325-425

375-475

2

3

425-525

475-575

525-625

4

5

6 y minimal number of busy tones neccessary for detection [2-0], where 0 means 10 busy tones z minimal time of permanent tone duration (for dial

575-675

625-725

675-775

725-825

7

8

9

0 tone detection on PBX) [1-5 sec]

Parametr Value Description Default

BRAVE

– user guide

37

503

504 tt mm

Time of tone duration DTMF (tone) dial

(04-16)

Time of space duration between DTMF tones (04-16)

10 (100ms)

10 (100ms)

505 f Time of Flash duration (1-6) 1 (100ms)

506 p

Time of pause duration / pause between numbers

(1-0)

4 (800ms) tt –Time of tone duration DTMF (tone) dial is calculated up:

(inserted number) x 10 = tone duration time [ms]

[range 04-16 tj. 40-160ms] m – Time of space duration between DTMF tones is calculated up:

(inserted number) x 10 =pause duration time [ms]

[range 04-16 tj. 40-160ms] f – Time of Flash duration is calculated:

inserted number x 100 = Flash duration time [ms]

[range 1-6 tj. 100-600ms] p – Time of pause duration is calculated:

inserted number x 100 + 400 = pause duration time [ms]

[range 1-0 tj. 500-1400ms]

– time p is also time of pause between numbers at pulse dialling

Parametr Value Description Default

507 uu

Level of sending tone DTMF dial in

[-dBm](04-16)

10 uu – level of sending tone (DTMF) dial into line, range is -4 to -16dBm. You insert desired level, uu=04 is -4dBm, uu=10 is -10dBm

Parametr Value Description Default

508 p preemphase DTMF (0/1) 0

509 S Listening –in DTMF - level (1-4) 2 p – preemphase is rate between upper and lower groups of DTMF frequency.

You can select rate 2,2 dB - p=0 (Europe) or rate 3,2dB - p=1 (Australia) s – listening –in DTMF level you can select in four levels:

Level of listening in DTMF [dB] s - dial

-15

-9

-3

+3

1

2

3

4

38 BRAVE

– user guide

5.5 System parametres

Parametr Value Description Default

61 z

Acoustic signalling (confirmation, error, empty memory, call termination...) (0/1)

1

In default the stages of door intercom are acoustically signalling. By parametr

z“ you can switch off this signalling. Possible values are z=0 – signalling is off z=1 – signalling is on

Parametr Value Description Default

62 v

Acoustic signalling off hook/on hook

(0/1/2)

1

In default is signalling pick up and hang up of the line. If you identify some problems at certain PBXs you can switch it off by p arametr „v“ . The possible values are: v=0 – signalling OFF HOOK / ON HOOK is off v=1 – signalling OFF HOOK / ON HOOK is on (type 1) v=1 – signalling OFF HOOK / ON HOOK is on (type 2)

Parametr Value Description Default

63 u Acoustic signalling knocking to call (0/1) 0

In default it is switch off. By activation of this feature you can identify at PBX calling from door intercom just up knocking into call. Possible values are: u=0 – knocking to call is off u=1 – knocking to call is on

Parametr Value Description Default

64 w

Powering from external power supply 12V

(DIP 3,4) (0/1)

0

In version /C only or at version (C) .

In default external power supply is OFF.

Activation has a sense only in cases when door intercom should make some operation during stand by mode – relay activation. Relay in mode m=7 allows permanent closing even after call termination. Relay mode m=8 allows activation up DAY/NIGHT mode settings even after call termination. In those cases you have to provide external power supply to dont flow current at hanged up line. The DIP switch 3 and 4 must be in position „on“ to activate this parametr

w=1 . Deactivation - w=0.

BRAVE

– user guide

39

Parametr Value description Default

65 z Acustic signalling of relay activation (0/1) 0

In default the activation is off z=0. Usually you can use this fetaure for DC power supply 12 V. Then when el.lock is released you dont hear „buzzing“ so visitor doesnt know that el.lock is released. When you activate this feature z=1 then during relay activation you hear special sounds simulating relay activation.

Note.1 This feature is available for relay mode m=1, m=5 only.

Note.2 For relay activation with 2 pulses the acoustic signalling sounds during whole time of sequence. (even in space between pulses)

Parametr Value Description Default

66 i

Suppression of DTMF reception from microphone (0/1)

0

In default the suppression of DTMF reception from MIC is off i=0. Due this you can activate relay by personal dialler without ringing to person inside building. To increase security you can activate suppression of DTMF reception from microphone i=1 and due this protect entrance of persons who provided record of

DTMF code for door opening.

Parametr Value

67 b

Description

BabyCall

– call without neccessity programm phone number (0/1)

Default

0

In default is switch off b=0. By activation this feature b=1 is cancelled acoustic signalling of empty memory. After pushing of button with empty memory you get just beep (confirmation) and call is established as normal dialled number

Caution: first 10sec of call is not active tone detector (it waits on reaction of PBX and number dialling by PBX)

Parameter Value Meaning Basic

68 b Mute at the lock activated (0/1) 0

Default is off m = 0 By enabling the m = 1 mutes the acoustic path at close relay

(1 or 2) in "electric lock" (modes 1 and 5). This feature is there because if you often use code lock function or exit button, so the switch-on time to hear the tone exchange. For some customers, this can be distracting.

40 BRAVE

– user guide

Parametr Value

6* t

Description delay start for PBx´s with line testing

(Siemens) (0/1)

Default

0

In default is switch off t=0. By activation this feature t=1 is processor going to

„sleep mode“ after line connection and after 3sec the door intercom makes initialization. It delays line picks up after line ( voltage) connection – activation status / PBX restart. When this feature is not efficient and PBX still evaluate the line into „failure“ mode“ then you have to use external power supply – put DIP switch 3 and 4 to position "on" – possible at version /C (C) only. It is the same like using Best Box option.

BRAVE

– user guide

41

5.6 HandsFree parametres setting

Parametr Value Description Default

71 gg

Reception loudness 01-16 (16 is highest)

(SPK)

07

72

73 ff rr

Transmission loudness 01-16 (16 is highest)

(MIC)

Speaker loudness 01-16 (16 is highest)

(TRH)

07

07 gg / ff / rr – numbers are inserted always by 2 digits in range [01-16]

After reception of confirmation ♫ is new value immediatelly active and you can test it.

Help: except inserting of direct values 01-16 you can add/ decrease amplification

+/- by buttons on phone

*

=

-

and

#

=

+

Limits of maximal and minimal loudness are acoustically signalling (3 tones as call termination signalling. When you dont press any digit within 5sec then setup value is saved and you hear confirmation tone ♫.

CAUTION !! We dont recommend factory setting if neccessary.

Parametr Value Description Default

74 c Soft pass of switching (0/1) 1

In default this feature is off c=0. It is going about character of on line operation semiduplex switching. In case where character of depresser is too steep you can make it softer by c=1.

Parametr Value Description Default

75 n Depression of background sound (0/1) 1

In default it is off n=0. When door intercom is installed in noicy environment

(noicy streets, subway stations, parkings…) then by activation of this circuit n=1 is setup level of noice as start level for microphone activation. Then the call connection is not one way opened. It relates with setup of parametres 71, 76, 77.

42 BRAVE

– user guide

Parametr Value Description Default

76 b Level of microphone start 1-4 (4 is highest) 2

On the line is simultaneously signal from microphone and speaker. In handsfree circuit is a few functional blocks to suppress acoustic shock. The basic one is circuit of semiduplex operation when incoming signal decrease microphone amplificatio as same as signal from microphone decrease incoming signal. The level of microphone start is setup by this parametr.. As lower value as higher microphone sensitivity is. In noicy environment we recommend higher value with combination of parametrs 71,75, 77.

Parametr Value Description Default

77 s

Fast switching voice automatic 1-4 (4 is slowest)

2

At parametres 75, 76 is descriped principal of acoustic shock supression. Speed of circuit switching between incoming and outgoing sound is setup by parametr

77.

Switching time

[ms]

1

2

4

8

S - dial

1

2

3

4

Parametr Value Description Default

78 l

VoltAmper (VA) charakteristic of line connection (0/1)

1

Almost every country around the world has different telephone directives and this parametr allows decrease voltage at door intercom line interface about 1V during

OFF HOOK. Where directive requires decreasement of line voltage I=0 decrease voltage about 1V. In default l=1.

BRAVE

– user guide

43

Parametr Value Description Default

79 k

Compemsation of wires losses depends on line current (0/1/2)

1

Door intercom Brave includes circuit which during long distance installations

(100m and more from PBX) can compensate losses on wiring. In default the feature is off k=0. You can setup in two levels depending on line current of PBX

(short circuit current I

0

).

PBX current I

0

k - dial

Feature is off

20mA-50mA

45mA-75mA

0

1

2

Parametr Value Description Default

70 uu

Transmission signalling level in [-dBm] (04-

16)

10 uu – transmission signalling level to the line, range -4 to -16dBm. You insert desired level, uu=04 is -4dBm, uu=10 is -10dBm ...

44 BRAVE

– user guide

5.7 Time programm

– automatic DAY/NIGHT switching (C)

(C) version only !

Parametr Value Description Default

09 a

ON / OFF automatic DAY/NIGHT switching and setting time control (0/1/#)

0

When door intercom Brave includes RTC circuit - (C) version then you can activate automatical switching from real time a=1. The condition is correct time settings. You can verify it easily by diallingu a=# and door intercom reply either by confirmation tone (all is correct) or error tone (you have to setup the time). By dial

a=0 you deactivate automatical switching.

Parametr Value Description Default

081

082 hhnn Time settings hh-hours, nn-minutes ddmmyyw

Date settings dd-day, mm-month, yy-year, w-weekday

# wait 1 min for seconds zeroing

-

-

083 -

Internal clocks parametres setting. After setting by command 083# zeroing seconds setting any through this agreed clocks exactly up seconds. w - weekday: 0 - Sunday

1 - Monday

2 - Tuesday

3 - Wednesday

4 - Thursday

5 - Friday

6 - Saturday

Example: you want set 27.5.2011 9:39 (its Friday), then dial sequence:

0822705115 you hear tone ♫, then dial 0810939 hear tone ♫ and finally dial 083

– wait for exact time sec=0 . In this moment dial # and you hear tone ♫ - finished.

BRAVE

– user guide

45

Parametr Value

00

01

02

03

04

05

06

07 hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj

#

Description

sunday

– time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

monday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

tuesday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

wednesday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night

thursday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night

friday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

saturday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night overwrite (copyright) setting from sunday

(00) into whole week

Default

00000000

00000000

00000000

00000000

00000000

00000000

00000000

-

By parametres 00-06 are setting times of automatic switching DAY/NIGHT for every day in week. The parametr 07 is designed for copying when setting is the same for whole week. Then you setup switching times for parametr 00 (sunday) and then by parametr 07# you copy this setting into remaining days.

Examples:

1. monday 8:00 starts day, 17:05 starts night, tuesday 7:30 starts day and in 16:00 starts night.

Setting sequence: 0108001705 a nd ♫, then 0207301600 and ♫

2. In Thursday starts day 6:45 and night starts 15:05, on Friday night continue until 15:00 and then starts day and it is until saturday 12:00 , then is night. Here you can use setting of switching inside one day into night even night is still valid from previous day and again switching into day even day is valid from previous day. Then for setting after midnight you insert time 00:00.

Setting sequence: 0406451505 and

♫, 0515000000 and ♫, 0600001200 and ♫

46 BRAVE

– user guide

5.8 Default settting and erasing

Parametr Value

84

85

86

87

Description

Default settings for parametres 7x only

Default

8# # Default execute

This setting doesnt change parametres 1 and 2 (numbers saved in memories)

Parametr Value Default

81

82

83

Description

Erase all numbers in group 1

(Day mode)

Erase all numbers in group 2

(Night mode)

Default settings for parametres 3x only 3 only..

Default settings for parametres 4x only

Default settings for parametres 5x only

Default settings for parametres 6x only

4 only..

5 only..

6 only..

7 only..

80 Default settings for parametres 0x only 0 only..

Parametres 81 and 82 makes erasing of all numbers saved in button memories.

Parametres 83 – 87,80 makes default settings for parametres starts 3,4,5,6,7,0 only. Default settings values are mentioned at every parametr in right - column

"Default".

CAUTION !!! the erasing is unreturnable !!! it is neccessary programm again

5.9 Programming termination

Parametr Value Description

9 E N D of programming

After 9 dial in programming tone the door intercom hangs up.

Default

BRAVE

– user guide

47

5.10 Parametres overview

Parametr Value

1

2

Description

tt nn… number nn under button tt

tt nn… number nn under button tt

31 r m

31

32 r* tt rp hh... relay r works in mode m (1-8) button tt activate relay closing r in mode m=6 (01-99)

In mode DAY + NIGHT password hh... for relay r, in order p=1-5, for 1 pulse and p=* for 2 pulses (00-999999)

In mode DAY password hh... for relay r, in

33 rp hh...

(00-999999)

In mode NIGHT password hh... for relay r, in

34 rp hh...

35

36 r aa r cc

(00-999999) command aa from phone for closing relay r

1 pulse (00-99,*0-*9) command aa from phone for closing relay r

2 pulses (00-99,*0-*9)

Default

-

-

11 21

01

-

155 266

150 260

37 r ss

38

39

30

3#0

3#1

3#1

3#1

3#1

3#5

41

42 r p xx r zz p abcd abcd abcd abcd abcd v z

(01-99)

Relay control r during incoming call

(0/1)

time xx [sec] between relay closing 1 and 2 in mode m=5 - doba t3 (01-99) time zz [sec] between pulses during closing for 2 pulses of relay r - doba t2/t5 (01-

99)

p = 1 enabled / disabled p = 0 connection code relay COSW (0/1) activation code 1 pulse from buttons

(0000-1111) activation code 1 pulse from phone

(0000-1111) activation code 2 pulses from buttons

(0000-1111) activation code 2 pulses from phone

(0000-1111) activation code from other modes of switch

(0000-1111)

Dial type v – tone / pulse (0/1)

Character for call prolongation (* / #)

11 21

10

105 205

0

0000

0000

0000

0000

0000

0

*

48 BRAVE

– user guide

56

500

501

502

52

53

54

55

43

44

45

46

47

4*

51

503

504

505

506

507

508

509

61

62

63

64

65 d w z z g bb

Command to hang up door intercom by phone

(00-99,*0-*9) xxxx Service password (0000-9999)

Command to switch into DAY (00-99,*0-*9) dd nn Command switch into NIGHT (0099,*0-*9) e k q

Door intercom dial mode (0/1)

Feature of line hanging up by again push of the same button (0/1)

Number of rings before door intercom pick up incoming call (1-9)

Maximal call duration (0-9,*,#)

Time between button push (1-9)

Hang up time before REDIAL (1-5)

Time before dial start (1-5) hh x y z tt mm

S w

BRAVE

– user guide f p uu p z v u z

155 266

0000

11

10

1

1

2

2

2

2

1

Number of ringing before hang up (04-99) 12

Middle frequency of tone detector (1-0) 3 (375-475Hz)

Number of busy tones (2-0) 4

Duration time of permanent tone (1-5) 3 (3s)

Duration time of tone DTMF of tone dial

(04-16)

10 (100ms)

Time of space between each DTMF tones

(04-16)

10 (100ms)

Flash duration time (1-6) 1 (100ms)

Pause duration time / space between numbers (1-0)

Transmitting level of DTMF dial in [-dBm]

(04-16)

4 (800ms)

10 preemphase DTMF (0/1) 0

Listening in DTMF

– level (1-4)

Acoustic signalling (confirmation,error, empty memory, call termination...) (0/1)

Acustic signalling OFF HOOK /ON HOOK

(0/1)

Acoustic signalling of beeping into call (0/1)

External powering from power supply 12V

(DIP 3,4) (0/1)

Acoustic signalling of relay activation (0/1)

2

1

1

0

0

0

49

50

71

72

73

74

75

76

77

78

79

70

09

081

082

083

66

67

68

6*

00

01

02

03

04 i b b t gg ff rr

Depression of DTMF reception from microphone (0/1)

BabyCall – call without neccessity to insert phone number (0/1)

Mute at the lock activated (0/1)

Delay start for PBX´s with extension test

(Siemens) (0/1)

Reception loudness 01-16 (16 is highest)

(SPK)

Transmission loudness 01-16 (16 is highest)

(MIC)

Speaker loudness 01-16 (16 is highest)

(TRH)

Soft pass of switching (0/1) c n Depression of background sound (0/1) b Level of microphone start 1-4 (4 is highest) s l k uu a

Fast switching voice automatic 1-4 (4 is slowest)

VoltAmper (VA) charakteristic of line connection (0/1)

Compemsation of wires losses depends on line current (0/1/2)

Transmission signalling level in [-dBm] (04-

16)

ON/ OFF automatic switching DAY/NIGHT mode and time settings control (0/1/#) hhnn Time settings hh-hours, nn-minutes ddmmyy Date settings dd-day,mm-month,yy-year

0

0

0

0

07

07

07

1

1

2

2

1

1

10

0

-

-

# hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj

Wait for 1 min for seconds zeroing

sunday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

monday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

tuesday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

wednesday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night

thursday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night

-

00000000

00000000

00000000

00000000

00000000

BRAVE

– user guide

05

06

07

8#

81

82

83

84

85

86

87

80

9 hhnnkkjj hhnnkkjj

#

friday - time setting hours hh and minutes

nn starts day and hours kk and minutes jj starts night

saturday - time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night overwrite (copyright) setting from sunday

(00) into whole week

# default

Erase all numbers in group 1

(DAY mode)

Erase all numbers in group 2

(NIGHT mode)

Default setting for parametres 3x only

Default setting for parametres 4x only

Default setting for parametres 5x only

Default setting for parametres 6x only

Default setting for parametres 7x only

Default setting for parametres 0x only

END

00000000

00000000

- execute

3 only..

4 only..

5 only..

6 only..

7 only..

0 only..

BRAVE

– user guide

51

6 Technical parametres

6.1 Elektrical parametres

Parametr

Minimal line current

Minimal line voltage

Line voltage during OFF HOOK

(VA characteristic)

Downlead during ON HOOK

Line termination impedance

Bandwidth

Ringing impedance

Sensitivity of ringing detector

Pulse dial

Tone dial level

Value Conditions

18mA

18V

< 8V

< 12V 1 )

Line OFF HOOK

Line ON HOOK

I = 20mA

I = 60 mA

< 30uA U = 60V

220R +

820R paral. 115nF

300Hz – 3400 Hz

> 2Kohm

Line OFF HOOK

20 - 60mA

25 min. 10 – 25 V

– 60 Hz

40 / 60 ms

-6 and -8 dB

1 ) min. -40 dB min. -30 dB

20

20

20

– 60 mA

– 60 mA

– 60 mA

Sensitivity of tone dial

Sensitivity of tones detector

Powering of backlight, relays and heating

Max consumption of backlight and heating

Max voltage of relay contact

Max current of relay contact

Operation temperature

IP rate

Weight

Camera

1 ) - possible setting by progam

12Vss ± 2V , 10-12Vst ± 2V

250mA 12Vss

48V

1,5A when I < 1A when U < 30 V

- 20 to + 60 st

IP44 max. 350g

Parametres on page 18

6.2 Mechanical dimensions

Model

Brave Smyle (1 and 2 buttons)

Weather hood

Brave with weather hood

Screw 2x

Wall plug 2x

dimension HxWxD [mm]

185 x 99 x 40

68 x 103 x 60

187 x 103 x 60 screw 3.5x30 halfround head

UPA,UPP pr. 5 x 25

52 BRAVE

– user guide

7 Table for easy programming

Into empty parts of table write values which you desire to programm. In double linked part are mentioned programming commands for easy programming. Moreover the programmed values stay in manual for future changes.

Description Programming sequence digits description detail par. Fill up your values

Number under button 1 Day/1gr. 101

Number under button 2 Day/1gr. 102

Number under button 3 Day/1gr. 103

Number under button 4 Day/1gr. 104

Number under button 5 Day/1gr. 105

Number under button 6 Day/1gr. 106

Number under button 7 Day/1gr. 107

Number under button 8 Day/1gr. 108

Number under button 9 Day/1gr. 109

Number under button 10 Day/1gr. 110

Number under button 11 Day/1gr. 111

Number under button 12 Day/1gr. 112

1 Number under button Night/2gr 201

2 Number under button Night/2gr 202

3 Number under button Night/2gr 203

4 Number under button Night/2gr 204

5 Number under button Night/2gr 205

6 Number under button Night/2gr 206

7 Number under button Night/2gr 207

8 Number under button Night/2gr 208

9 Number under button Night/2gr 209

10 Number under button Night/2gr 210

11 Number under button Night/2gr 211

12 Number under button Night/2gr 212 relay 1 works in mode relay 2 works in mode m=1 - 8 311 m=1 - 8 312

3211 Password for relay 1

(1 pulse)

Day+Night

BRAVE

– user guide

1

1

6

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

53

password relay 1 (1pulse) Day/Night 3212 password relay 1 (1pulse) Day/Night 3213 password relay 1 (1pulse) Day/Night 3214 password relay 1 (1pulse) Day/Night 3215 password relay 1 (2pulses) Day/Night 321* password relay 2 (1 pulse) Day/Night 3221 password relay 2 (1 pulse) Day/Night 3222 password relay 2 (1 pulse) Day/Night 3223 password relay 2 (1 pulse) Day/Night 3224 password relay 2 (1 pulse) Day/Night 3225 password relay 2 (2 pulses) Day/Night 322*

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Day 3311

Day 3312

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Password relay 1 (2 pulses)

Day 3313

Day 3314

Day 3315

Day 331* password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (2 pulses)

Day 3321

Day 3322

Day 3323

Day 3324

Day 3325

Day 332*

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Password relay 1 (1 pulse)

Password relay 1 (2 pulses) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (1 pulse) password relay 2 (2 pulses)

Night 3411

Night 3412

Night 3413

Night 3414

Night 3415

Night 341*

Night 3421

Night 3422

Night 3423

Night 3424

Night 3425

Night 342*

54 BRAVE

– user guide

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

Button selection for relay 1 m=6 311*

Button selection for relay 1 m=6 312*

Relay 1 activation by phone 1 pulse 351

Relay 2 activation by phone 1 pulse 352

Relay 1 activation by phone 2 pulses 361

Relay 2 activation by phone 2 pulses 362

Time of closing for relay 1 [sec] 371

Time of closing for relay 2

Incoming call relay1 control

[sec]

1 / 0

1 / 0

372

381

382 Incoming call relay2 control

Delay between closing relay 1 and 2

Time between pulses rel 1

Time between pulses rel 2

[sec]

[sec]

[sec]

39

301

302

Enable code relay (COSW-sw.1) 0/1 code for activation 1 imp./btn.

0000-1111 code for activation 1 imp./phn.

0000-1111 code for activation 2 imp./btn.

0000-1111 code for activation 2 imp./phn.

0000-1111 code for activation other mode 0000-1111

3#0

3#1

3#2

3#3

3#4

3#5

Dial type tone / pulse

Call prolongation character

Brave hanging up by phone

Brave hanging up by phone

Service password

Code to switch into DAY

Code to switch into NIGHT

Door intercom dial mode

Hang up by same button p.

0 / 1

* / #

1.

2.

1 / 0

0 / 1

Number of rings for pick up

Maximal call duration

Time before dial start

Numb of rings bef. Hang up

BRAVE

– user guide

[min]

Time between button press [sec]

Hang up time - REDIAL [sec]

[sec]

Tone detector frequency table

41

42

431

432

44

45

46

47

4*

51

52

53

54

55

56

500

2

1

1

2

2

2

2

2

2

2

2

1

1

1

1

1

2 ms 1

1

1

2

2

4

2

2

1

1

2

2

1

4

4

4

4

4

55

Number of busy tones

Time duration of permanent tone

Time duration of tone dial nn x 10

Space betweeni DTMF tones

Flash duration nn x 10 n x 100 pause/ space between numbers

DTMF transmission level n x100+400

04-16

501

502

503

504

505

506 preemphase DTMF 0 / 1

Listening in DTMF - level 1-4

507

508

509

Acustic signalling

Acustic signalling Off hook

/on hook

Acustic signalling beeps

External power supply 12V

Acustic signalling of relay activation

Depression of DTMF reception from microphone

BabyCall

0 / 1

0 / 1

0 / 1

0 / 1

0 / 1

0 /1

61

62

63

64

65

66

0 / 1 67

Mute at the lock activated

Number of buttons on panel

0 / 1

Up model

Delayed start (Siemens)

68

6#

6*

01-16 71 Reception loudness (TRH)

Transmission loudness

(MIC)

Speaker loudness (SPK)

01-16

01-16

0 / 1

72

73

74 Soft pass of switching

Depression of background sound

Level of microphone start

Fast switching voice automatic

VA charakteristic

Compemsation of wires losses

Signalling transmission level on/off.

automatic switching

0 / 1

1 - 4

1 - 4

0 / 1

0 / 1 / 2

04 - 16

0 / 1 / #

75

76

77

78

79

70

09

56 BRAVE

– user guide

1 sec 2 ms 2 ms 2 ms 1 ms 1

-dBm 2

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

1

1

1

1

1

1

-dBm 2

0

Time setting hhnn

Date setting+weekday w ddmmyyw sunday

Monday

Tuesday

Wednesday thursday friday saturday hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj hhnnkkjj

081

082

00

01

02

03

04

05

06

4

7

8

8

8

8

8

8

8

BRAVE

– user guide

57

Producer:

Distributor:

Sales date:

© JR 2011-13 verze 2.6 X/13