Arjay Engineering
Technical support 1(800)-398-9487
Arjay Engineering
Price List
Effective: March 1, 2003
CAPACITANCE INSTRUMENTS
Technical Support & Delivery Schedules
1-800-387-9487 (N.A. Toll Free)
+1 (905) 829-2418
+1 (905) 829-4701
www.ArjayEng.com
Description
Page
Level Instruments
2000
Level-Ease Series (remote mount)
-two relay setpoints
-four relay setpoints
-continuous monitors
-multi tank configurations
- single or dual Probe monitor
2
9820
9830
9080
Level Switch (probe mount)
Level Switch (remote mount)
Level Transmitter (probe mount)
4
5
6
Probe
Ordering Sheet
7
Specialty Instruments
9820-OWS
Oil/Water Separtor Switch
9830-OWS
Remote Oil/Water Switch
2114-OWS
Oil/Water Separtor Monitor
9830-HCF
Hydrocarbon Float Sensor
2114-HCF
Hydrocarbon Float Sensor
2114-OCF
Open Channel Flow Monitor
9820-DPM
Dry Pump Monitor (probe mount)
9830-DPM
Dry Pump Monitor (remote mount)
9830-ILA
Interstitial Leak Alarm
9830-LPS
Leak Pad Sensor
9830-PCD
Plugged Chute Detector
9
10
11
12
13
14
15
16
17
18
19
Instrument Options & Accessories
Electronic Replacement Parts & Spares
20
21
The Level-Ease 2000 control unit is mounted remote from the tank via 2 conductor shielded cable
using the ARJAY PMC card in the probe head. This provides operator and electrical installation safety
and controls. The control unit can be ordered to suit the application needs. The base unit is ordered
and each feature is added on through the following work sheet.
Page 1
Arjay Engineering
Technical support 1(800)-398-9487
Level-Ease 2000 Work Sheet
Part 1: Control Unit (includes pulse card for probe(s)
code
2
2
price
base unit
Arjay Level-Ease 2000 Capacitance Level monitor
code
probe input and controller mounting
1
single probe input (stand alone unit, includes keypad/display)
2
dual probe input (stand alone unit, includes keypad/display)
3
single probe input (multi-tank mounting, requires calibrator)
4
dual probe input (multi-tank mounting, requires calibrator)
code description (output isolated)
~
0 no 4-20 mA output(s)
1 4-20 mA output (includes on output per probe unit)
code
relay output, 10amp@120vac, SPDT, dry, full differential
~
0
no relays
2
two independent relays
4
four independent relays (relay to probe input is user)
code power input
0 24 vdc, .5 amp
~
1 115 vac, 50/60 Hz
~
2 230 vac, 50/60 Hz
~
code
unit enclosure
0
no enclosure (subplate mounted)
~
1
type 4 X polycar w/ window
2
type 4 X polycar no window
3
other
__
__
__
__
__
Add a calibrator (if necessary) and probe from Part 2 & 3.
Part 2: Calibrator (Required for above 23XX and 24XX models only)
A00069
A00070
Portable Calibrator (9vdc battery) with display
Wall mount Calibrator/Scanner with display
can connect up to 100 units with RS-485 (2 wire)
Page 2
Arjay Engineering
Technical support 1(800)-398-9487
Part 3: Probe (most typical configuration, other styles available - See Level Probe Sheet
PAA-XXXX-Z
For straight walled metal tanks up to 12 feet+A618
3/4" npt, 316SS process connection
Teflon coated, explosion proof
(i.e. PAA-12IN-Z = 12" probe)
PBA-XXXX-Z
Heavy Duty Probe
For bulk materials or high agitation
1" npt, 5/8" diameter
(i.e. PBA-12IN-Z = 12" probe)
PJA-XXXX-Z
For non-metallic and horizontal tanks
2" npt, 316 SS process connection
316 SS concentric shield for probe
Teflon coated probe, explosion proof
For plastic tanks with corrosive chemicals, a standard duty probe with a SS
grounding SPIRAP and Kynar protection tube is available
Flexible probes, alternate materials, and various tank connections available
Type 4X fibreglass reinforced polycarbonate enclosures for use with multi-tank units.
(size will be determined by options)
A00353
20" x 16"
will house up to 5 x 23XX or 24XX series units
A00354
28" x 20"
will house up to 14 x 23XX or 24XX series units
A00355
40" x 32"
will house up to 36 x 23XX or 24XX series units
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 3
Arjay Engineering
Technical support 1(800)-398-9487
Model 9820 - Level Switch
This point alarm will actuate a relay on the presence or absence of material on the probe. The setpoint can
be adjusted to alarm anywhere along the length of an Arjay probe. The differential feature allows the relay
to cycle on and off between two distinct points along the length of one probe.
The electronics is explosion proof and is mounted directly on the probe.
A. Electronics
A00225
A00226
A00227
A00228
A00229
A00230
A00231
A00232
Input voltage
12vdc
12vdc
24vdc
24vdc
110vac
110vac
220vac
220vac
X-P rating
Group C, D
Group B
Group C, D
Group B
Group C, D
Group B
Group C, D
Group B
B. Probe
PEA-XXXX-Z
Standard probe
For straight walled tanks
3/4" npt, 316SS process connection
Teflon coated, explosion proof
(i.e. PEA-12IN-Z = 12" probe)
PFA-XXXX-Z
Heavy Duty Probe
For bulk materials or high agitation
1" npt, 5/8" diameter
(i.e.. PFA-12IN-Z - 12" probe)
Page 4
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830 - Remote Level Switch
This point alarm will actuate a relay on the presence or absence of material on the probe. The setpoint can
be adjusted to alarm anywhere along the length of an Arjay probe. The differential feature allows the relay
to cycle on and off between two distinct points along the length of one probe.
The electronics is remote from the probe up to 1 km using the Arjay PMC Card
A. Electronics
A00301
A00302
A00303
A00304
A00305
A00306
Input voltage
24vdc
24vdc
110vac
110vac
220vac
220vac
X-P rating
Group C, D
Type 4X
Group C, D
Type 4X
Group C, D
Type 4X
B. Probe
PAA-XXXX-Z
Standard probe
For straight walled tanks
3/4" npt, 316SS process connection
Teflon coated, explosion proof
(i.e. PAA-12IN-Z = 12" probe)
PBA-XXXX-Z
Heavy Duty Probe
For bulk materials or high agitation
1" npt, 5/8" diameter
(i.e. PBA-12IN-Z = 12" probe)
Page 5
Arjay Engineering
Technical support 1(800)-398-9487
Model 9080 - Level Transmitter
This probe mounted transmitter provides a 4-20 mA output over the calibrated range of the probe. The
input voltage is 24 vdc. Calibration is by a direct adjustment on the electronics or with the ease of the 2000CAL Handheld or 2000-CAP Scanner.
A. Electronics
A00036
Input voltage
24vdc
X-P rating
Group B
B. Probe
PCA-XXXX-Z
Standard probe
For straight walled tanks
3/4" npt, 316SS process connection
Teflon coated, explosion proof
(i.e. PCA-12IN-Z = 12" probe)
PDA-XXXX-Z
Heavy Duty Probe
For bulk materials or high agitation
1" npt, 5/8" diameter
(i.e. PDA-12IN-Z = 12" probe)
Optional
2000-CAL
2000-CAP
Portable Calibrator (9vdc battery) with display
Wall mount Calibrator/Scanner with display
can connect up to 100 units with RS-485 (2 wire)
Page 6
Arjay Engineering
Technical support 1(800)-398-9487
Standard Capacitance Level Probe Ordering
Other materials and configurations available - Contact Factory.
Probe Type Entrance Fitting Probe Length Length Units Options Special Configuration
Code:
P
1
2
3
4
5
6
Example:
P
A
A
36
IN
- D10
Z
1
A
J
B
Probe Type (316SS fitting)
TFE Coated Rigid Probes
- Remote Standard, 3/4" NPT
- Remote Concentric Shielded, 2" NPT
- Remote Heavy Duty, 1" NPT
C
K
D
- Integral 9080 Model, Std. 3/4"
- Integral 9080Concentric Shielded, 2" NPT
- Integral 9080 Model, HD, 1"
E
L
F
G
H
- Integral 9820 Model, Std. 3/4"
- Integral 9820 Concentric Shielded, 2" NPT
- Integral 9820 Model, HD, 1"
Flexible Probes
- Flex, PVC Coated Probe, 2"
- Flex, Tefzel Coated Probe, 2"
A
B
C
D
E
F
G
H
J
K
L
M
Entrance Fitting Adapters
- As provided above
- 1" NPT, 316 SS
- 1.5" NPT, 316 SS
- 2" NPT, 316 SS
- 1" 150# Flange, 316 SS
- 1.5" 150# Flange, 316 SS
- 2 " 150# Flange, 316 SS
- 3" 150# Flange, 316 SS
- 4" 150# Flange, 316 SS
- 1.5" Tri-Clamp, 316 SS
- 2" Tri-Clamp, 316 SS
- Wall Bracket
2
Continued…
Page 7
Arjay Engineering
Technical support 1(800)-398-9487
3
Probe Length - Price per inch
Standard (Std.)
Concentric Shielded
Heavy Duty (HD)
Flex, PVC Coated
Flex, Tefzel Coated
Probe Length - Price per millimeters
Standard (Std.)
Concentric Shielded
Heavy Duty (HD)
Flex, PVC Coated
Flex, Tefzel Coated
4
Probe Length Units
IN - Inches
MM - Millimeters
5
B
D
Options
- Input Letter for Option, Blank without
Rigid Probe Options:
- Welding of Probe fitting to Flange for full penetration
- Inactive Sheath, 316 SS (specify length)
E
- Spirap, 316 SS
F
- Kynar Protection Tube
G
- PVC Protection Tube
H
N
B
E
- Potted Probe Head w Remote PMC
-Probe bend - distance from fitting & degree of bend must be specified
Flexible Probe Options:
- Welding of Probe fitting to Flange for full penetration
- Spirap, 316 SS
J
K
L
M
- 316 SS Weight
- SS Turn Buckle
- Galvanized Turnbuckle
-Inactive sheath
X
Z
Special Configuration
- contains Special Configuration per description
- Probe is complete
6
7
Production Code
Leave Blank- used by factory
Page 8
Arjay Engineering
Technical support 1(800)-398-9487
Model 9820-OWS - Oil/Water Separator Level Alarm
This single point alarm will actuate a relay when the oil/water interface in a separator passes to within 4" of
the tip of the probe. The set point depth is determined by the length of the probe. The probe is 316SS
A332nto the probe.
A. Electronics
A00275
A00276
A00277
A00278
A00279
A00280
A00281
A00282
Input voltage
12 vdc
12 vdc
24vdc
24vdc
110vac
110vac
220vac
220vac
X-P rating
Group C, D
Group B
Group C, D
Group B
Group C, D
Group B
Group C, D
Group B
B. Probe
PEA-L1XX-D(L2)-Z Standard probe with sheath
L1 = Probe Length, L2 = probe length less 4"
3/4" npt, 316SS process connection
3/8" diameter Teflon coated, SS probe
1/2" 316SS inactive sheath to within 4" of probe tip
(i.e. PEA-12IN-D8IN-Z = 12" probe)
Page 9
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830-OWS - Oil/Water Separator Level Alarm
This single point alarm will actuate a relay when the oil-water interface in a separator passes to within 4" the
tip of the probe. The set point depth is determined by the length of the probe. The probe is 316SS
sheathed to allow calibration under the conditions of a normal water filled tank. The electronics are remote
from the probe, and can be mounted up to 1 km away.
A. Electronics
A00247
A00248
A00249
A00250
A00251
A00252
Input voltage
24vdc
24vdc
110vac
110vac
220vac
220vac
X-P rating
Group C, D
Type 4X
Group C, D
Type 4X
Group C, D
Type 4X
B. Probe
PAA-L1XX-D(L2)-Z Standard probe - 3/4"npt, process connection
L1 = Probe Length, L2 = probe length less 4"
3/8" diameter Teflon coated, SS probe
1/2" 316SS inactive sheath to within 4" of probe tip
(i.e. PAA-12IN-D8IN-Z = 12" probe)
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 10
Arjay Engineering
Technical support 1(800)-398-9487
Model 2114-OWS - Oil/Water Separator Continuous Monitor
This capacitance based monitor provides accurate, reliable level measurement when used in conjunction
with a gravity flow 'equal volume in - equal volume out' style of separator. The unit is calibrated once
installed and reads the level of separated floating oil. Alarms, a pump run relay, display and signal output
are standard.
A. Electronics
2114-OWS-0-1
2114-OWS-1-1
2114-OWS-2-1
Input voltage
24 vdc
110 vac
220 vac
B. Probe
A00526-"LENGTH" Teflon coated probe per specified length
316 SS Shield with 2" npt process connection
explosion proof head
(i.e.A00526-12" = 12" probe)
C. Option
A00071
Note:
Intrinsic Safety Barrier
installed at the controller, makes the sensor
intrinsically safe
Provide enough probe length to ensure the head will be above possible water surging. The actual
level range used on the probe will be calibrated once installed. Separators are typically efficient
until the oil in the separator reaches 40% of the upper level. Therefore, the probe length should
be sized to provide a submersion to approximately 50% of the tank depth.
Page 11
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830-HCF - Hydrocarbon Float Sensor
For monitoring the upper surface of water to alarm on the presence of separated oil at the surface. The
floats allow the sensors to follow changes in the water level. When oil separates to the water surface, the
9830-HCF control unit activates a relay. The 9830-HCF electronics is installed remote from the sensor
which allows easy access for wiring and calibration.
A. Electronics
A00235
A00233
A00236
Input voltage
24 vdc
110 vac
220 vac
B. Probe
A00083
Float Sensor, 304 SS wetted parts
PVC sensor housing
10 meters of cable (float to PMC)
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 12
Arjay Engineering
Technical support 1(800)-398-9487
Model 2114-HCF - Floating Oil on Water Sensor
For monitoring the upper surface of water to indicate the presence of separated oil at the surface. The float
allows the sensor to follow changes in the water level. As the water in front of the sensor is replaced by oil,
the 2114-HCF provides a display of the surface oil level, relays for control, and a 4-20 mA output.
A. Electronics
2114-HCF-0-1
2114-HCF-1-1
2114-HCF-2-1
2214-HCF-0-1
2214-HCF-1-1
2214-HCF-2-1
Input voltage
24 vdc, single float input
110 vac, single float input
220 vac, single float input
24 vdc, dual float input
110 vac, dual float input
220 vac, dual float input
B. Probe
A00083
Float Sensor - Style A
For maximum level oil thickness of 1" (25.4 mm)
304 SS floats with PVC sensor housing
Type 4X housing for PMC card near sensor
10 meters of cable (float to PMC)
A00525
Float Sensor - Style B
For oil depths up to 24" (610 mm)
float assembly as above with shielded probe
304 SS wetted parts
C. Option
A00071
Intrinsic Safety Barrier
installed at the controller, makes the sensor
intrinsically safe
(one barrier per float required)
Page 13
Arjay Engineering
Technical support 1(800)-398-9487
Model 2114-OCF - Open Channel Flow Monitor
This capacitance based flow monitor provides accurate, reliable flow measurement when used in
conjunction with a primary flow device such as a weir or a flume. The menu of 23 pre-programmed weir and
flume sizes is standard. The level signal is linearized to the primary device to provide an LCD display of the
flow rate, with totalization, signal output and alarms.
A. Electronics
2114-OCF-0-1
2114-OCF-1-1
2114-OCF-2-1
Input voltage
24 vdc
110 vac
220 vac
B. Probe
A00526-"LENGTH" Teflon coated per specified length
316 SS shield with 2" npt process connection
explosion proof head
(i.e. A00526-12" = 12" probe)
C. Option
A00071
Note
Intrinsic Safety Barrier
installed at the controller, makes the sensor
intrinsically safe
Provide enough probe length to ensure the head will be above possible water surging. The actual
water level range used on the probe will be calibrated once installed.
Page 14
Arjay Engineering
Technical support 1(800)-398-9487
Model 9820-DPM - Dry Pipe/Pump Monitor
For monitoring of liquids travelling through a pipe or into a pump. The sensor mounts flush in-line with the
pipe or at the inlet of the pump to eliminate intrusion. When there is an absence of material in front of the
sensor due to a dry condition, the 9820-DPM control unit activates a relay. The 9820-DPM is installed
integral to the sensor for applications where the control wiring is desired at the pump, and vibration is not a
concern. For high vibration applications and remote electronics, refer to the 9830-DPM.
A. Electronics
A00324
A00325
A00326
A00258
Input voltage
12 vdc
24 vdc
115 vac
220 vac
B. Probe
Ring Flange Sensor
PVC wetted parts
explosion proof housing
150# ANSI hole sizing
A00165
A00166
A00167
A00168
A00169
A00170
A00136
A00153
Note.
1" (25 mm)
1.5" (39 mm)
2.0" (50 mm)
2.5" (54 mm)
3.0" (75 mm)
4.0" (100 mm)
6.0" (150 mm)
7.0" (200 mm)
Other materials (I.e. Kynar, Nylon) and sizes are available on request.
Page 15
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830-DPM - Dry Pipe/Pump Monitor
For monitoring of liquids travelling through a pipe or into a pump. The sensor mounts flush in-line with the
pipe or at the inlet of the pump to eliminate intrusion. When there is an absence of material in front of the
sensor due to a dry condition, the 9830-DPM control unit activates a relay. The 9830-DPM is installed
remote from the sensors to minimize the vibration affect on the electronics and to provide a safe accessible
calibration and wiring. For applications where the control wiring is desired at the pump, and vibration is not
a concern, the control unit can be be close to the sensor to provide an economical compact system.
A. Electronics
Input voltage
24 vdc
115 vac
220 vac
A00256
A00257
A00258
B. Probe
Ring Flange Sensor
PVC wetted parts
explosion proof housing
150# ANSI hole sizing
A00165
A00166
A00167
A00168
A00169
A00170
A00136
A00153
Note.
1" (25 mm)
1.5" (39 mm)
2.0" (50 mm)
2.5" (54 mm)
3.0" (75 mm)
4.0" (100 mm)
6.0" (150 mm)
7.0" (200 mm)
Other materials (I.e. Kynar, Nylon) and sizes are available on request.
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 16
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830-ILA - Interstitial Leak Alarm
For monitoring the interstitial space of a double walled tank. The flexible sensor can be fed down between
the walls until the active tip of the probe is at the bottom of the cavity. When fluid intrudes in the interstitial
space, the 9830-ILA control unit activates a relay. The 9830-ILA is installed remote from the sensor to
provide a safe and accessible calibration and wiring.
A. Electronics
A00262
A00263
A00264
Input voltage
24 vdc
115 vac
220 vac
B. Probe
PGA-XXXX-M-X
Flexible probe
3/4" npt process connection
PVC jacketed probe
316 SS sheath
explosion proof head
(i.e. PGA-120IN-M-X = 120" Probe)
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 17
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830-LPS - Leak Pad Sensor
For monitoring of containments, vaults, floors, etc. for the presence of a liquid in a normal dry condition. Up
to three pads may be operated on one control unit with a common alarm. When liquid leaks beneath the
raised sensing pad, the 9830-LPS unit activates a relay. The 9830-LPS is installed remote from the sensing
area to provide a safe and accessible calibration and wiring.
A. Electronics
A00267
A00268
A00269
Input voltage
24 vdc
115 vac
220 vac
B. Probe
A00062
Leak pad Sensor
polycarbonate & epoxy resin sensor puck
6 meters of cable to PMC card
up to 3 pads per PMC and control unit
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 18
Arjay Engineering
Technical support 1(800)-398-9487
Model 9830-PCD - Plugged Chute Detector
For monitoring bulk materials (i.e. coal, chips, pellets) travelling through a chute or pipe. The sensor
mounts flush into the wall to eliminate intrusion. When the material in front of the sensor compacts due to a
plugged condition, the 9830-PCD unit activates a relay. The 9830-PCD is installed remote from the sensor
to minimize the vibration affect on the electronics and to provide a safe and accessible calibration and
wiring.
A. Electronics
Input voltage
24 vdc
115 vac
220 vac
A00272
A00273
A00274
B. Probe
Flush mount sensor
UHMWPE (polyethylene) facing
316 SS backplate
wall insert thickness as specified by customer
(consult factory for wall thickness > 150 mm)
A00177
A00178
A00179
Note:
F-4 100 mm x 100 mm (approx. 4" x 4")
F-6 150 mm x 150 mm (approx. 6" x 6")
F-8 200 mm x 200 mm ( approx. 8" x 8")
Other facing materials, sizes and shapes are available on request.
Curved sensors are available for pipe and cyclones
C. Option
A00071
Intrinsic Safety Barrier
installed at 9830 controller, makes the sensor
intrinsically safe
Page 19
Arjay Engineering
Technical support 1(800)-398-9487
Instrument Options and Accessories
The following items are factory installed on or into ordered enclosures.
A00237
A00130
A00238
A00239
A00071
A00259
A00421
A00422
Red & green light, Type 4 heavy duty
Door mounted flashing red light - Type 4X
Push button jog - Type 4X heavy duty
Buzzer with Acknowledge/Silence, 80 dcB @ 10', push button to
silence
Intrinsic Safety Barrier, installed at probe input to controller,
provides intrinsic safety to probe
Enclosure strip heater - on 10°C, off 20°C
4-20 mA loop powered display, panel mount supplied loose
4-20 mA loop powered display, explosion proof with viewing
window, wall or conduit mount
Type 4X fiberglass reinforced polycarbonate enclosures
Size will be determined by options
A00353
A00354
A00355
20" x 16"
up to 5 x model 23XX or 24XX series units
28" x 20"
up to 14 x model 23XX or 24XX series units
40" x 32"
up to 36 x model 23XX or 24XX series units
Page 20
Arjay Engineering
Technical support 1(800)-398-9487
Electronic Replacement Parts and Spares
Model 9820
A00240
A00241
A00424
A00425
A00333
Input voltage
12 vdc
24 vdc
115 vac
220 vac
Main Circuit Board
Main Circuit Board
Main Circuit Board
Main Circuit Board
2 fuses
Model 9830
A00329
A00330
A00331
A00332
A00415
Input voltage
24 vdc
115 vac
220 vac
Main Circuit Board
Main Circuit Board
Main Circuit Board
2 fuses
PMC-2000
Model 9080, 9080R
A00298
A00361
A00243
A00244
A00356
A00363
Input voltage
24 vdc
24 vdc
115 vac
230 vac
Board Set (2)
Power Supply Board
Power Supply Board
Power Supply Board
Flyboard
2 fuses
Model 9050, 9052, 9054 (Specify serial number when ordering)
Input voltage
A00357
24 vdc
Micro Board
A00358
Interface Board
A00361
24 vdc
Power Supply Board
A00243
115 vac
Power Supply Board
A00244
230 vac
Power Supply Board
A00060
PMC-9000 - potted
A00110
Relay Board with cable
A00362
2 sets of 2 fuses
A00418
Display, 4 line, no backlight
Model 9070, 9072, 9074 (Specify serial number when ordering)
Input voltage
A00357
24 vdc
Micro Board
A00359
Interface Board
A00060
PMC-9000 - potted
A00110
Relay Board with cable
A00334
2 sets of 2 fuses
Page 21
Arjay Engineering
Technical support 1(800)-398-9487
Model 9062, 9064 (Specify serial number when ordering)
Input voltage
A00357
24 vdc
Micro Board
A00360
Interface Board
A00361
24 vdc
Power Supply Board
A00243
115 vac
Power Supply Board
A00244
230 vac
Power Supply Board
A00060
PMC-9000 - potted
A00110
Relay Board with cable
A00334
2 sets of 2 fuses
Model 2000 Series
Input voltage
A00408
A00409
A00410
A00411
A00412
A00500
A00413
A00414
A00415
A00416
A00417
A00419
24 vdc
115 vac
230 vac
Micro Board
Model 210X, 230X Interface Board
Model 211X, 231X Interface Board
Model 220X or 240X Interface Board
Model 221X or 241X Interface Board
Power Supply Boards
Power Supply Boards
Power Supply Boards
PMC-2000 - potted
Relay Board with cable
2 fuses
Display - backlit, 4 line
Model 2000-CAP
A00419
A00408
A00500
A00413
A00414
24 vdc
115 vac
230 vac
Display - backlit, 4 line
Micro Board
Power Supply Boards
Power Supply Boards
Power Supply Boards
Model 2000-CAL
A00418
A00408
Display, 4 line, no backlight
Micro Board
Model 9000-CAP
A00357
A00358
A00361
A00243
A00244
A00418
Model 9000-CAL
A00418
Input voltage
24 vdc
24 vdc
115 vac
230 vac
Micro Board
Interface Board
Power Supply Board
Power Supply Board
Power Supply Board
Display - 4 line
Display, 4 line, no backlight
Page 22