Manual
Elinx EIRP410-2SFP-T
8 Ports10/100 PoE with 2 combo 10/100/1000 or 100/1000 SFP Ports
Unmanaged Din Rail Ethernet Switch
EIRP410-2SFP-T
Documentation Number: EIRP410-2SFP-T-0912m
International Headquarters:
707 Dayton Road
Ottawa, IL 61350 USA
Phone (815) 433-5100
Website: www.bb-elec.com
Sales e-mail: orders@bb-elec.com
Technical Support: support@bb.elec.com –
European Headquarters
B&B Electronics
Westlink Commercial Park
Oranmore, Co. Galway, Ireland
Phone +353 91-792444
Website: www.bb-europe.com
Sales e-mail: sales@bb-europe.com
Technical Support: support@bb-europe.com
Original – April 2011
©2011 No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any
information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on
the part.
B&B Electronics Manufacturing shall not be liable for incidental or consequential damages resulting from the furnishing, performance, or use of this manual. All brand
names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference
purposes only and does not constitute an endorsement by the trademark holder.
Table of Contents
INTRODUCTION ..................................................................................................................... 1
The EIRP410-2SFP-T is an industrial Managed Ethernet switch that has 8 10/100TX PoE ports and 2
10/100/1000T/Mini-GBIC Combo ports. .............................................................................................................................. 1
Features ................................................................................................................................................................................... 1
Package Contents ................................................................................................................................................................... 2
HARDWARE DESCRIPTION .................................................................................................. 3
Physical Dimension ................................................................................................................................................................ 3
Front Panel ............................................................................................................................................................................. 3
Front Panel of the PoE Industrial Switch ............................................................................................................................ 3
Top View ................................................................................................................................................................................. 4
Top View of the PoE Injectors Industrial SwitchLED Indicators ..................................................................................... 4
LED Indicators ....................................................................................................................................................................... 5
Ports......................................................................................................................................................................................... 6
RJ-45 ports ........................................................................................................................................................................... 6
2 Mini-GBIC combo port ..................................................................................................................................................... 8
Cabling .................................................................................................................................................................................... 8
Wiring the Power Inputs ..................................................................................................................................................... 11
Wiring the Fault Alarm Contact ......................................................................................................................................... 11
MOUNTING INSTALLATION ................................................................................................ 13
DIN-Rail Mounting .............................................................................................................................................................. 13
Wall Mount Plate Mounting ................................................................................................................................................ 15
NETWORK APPLICATION ................................................................................................... 16
Troubleshooting .................................................................................................................................................................... 17
TECHNICAL SPECIFICATION ............................................................................................. 18
Manual Documentation Number: EIRP410-2SFP-T-0912m
i
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Introduction
The EIRP410-2SFP-T is an industrial Managed Ethernet switch that has 8 10/100TX PoE ports and 2 10/100/1000T/MiniGBIC Combo ports.
Features
• System Interface/Performance
o
RJ-45 ports support Auto MDI/MDI-X Function
o
Embedded 8-ports PoE
o
SFP (Mini-GBIC) supports 100/1000 Dual Mode
o
Store-and-Forward Switching Architecture
o
Back-plane (Switching Fabric): 5.6Gbps
o
1Mbits Packet Buffer
o
8K MAC Address Table
o
Supports Wide Operating Temperature (-40oC ~ 75oC)
• Power Supply
o
Redundant Power Design
• Case/Installation
o
IP-30 Protection
o
DIN Rail and Wall Mount Design
• Relay Alarm
o
Relay output for port breakdown, power fail and alarm
1
Manual Documentation Number: EIRP410-2SFP-T-0912m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Package Contents
•
8 Ports10/100 PoE with 2 combo 10/100/1000 or 100/1000 SFP Ports Industrial Switch
•
User manual
•
Pluggable Terminal Block
•
2 wall mount plates and 6 screws
•
One DIN-Rail (attached on the switch)
8 10/100TX + 2 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Switch
User Manual
Wall Mount Plate
block connector
Screws
DIN-Rail
Manual Documentation Number: EIRP410-2SFP-T-0912m
2
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Hardware Description
The following information is an introduction to the Industrial switch’s hardware spec, port, cabling information, and
wiring installation will be described.
Physical Dimension
8 Ports10/100 PoE with 2 combo 10/100/1000 or 100/1000 SFP Ports Industrial Switch dimension (W x D x H) are
72mm x 105mm x 152mm
Front Panel
The Front Panel of the 8 Ports10/100 PoE with 2 combo 10/100/1000 or 100/1000 SFP Ports Industrial Switch is shown
as below:
Front Panel of the PoE Industrial Switch
Manual Documentation Number: EIRP410-2SFP-T-0912m
3
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Top View
The top view of the 8 Ports10/100 PoE with 2 combo 10/100/1000 or 100/1000 SFP Ports Industrial Switch has one
terminal block connector of two DC power inputs.
Top View of the PoE Injectors Industrial Switch
Manual Documentation Number: EIRP410-2SFP-T-0912m
4
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
LED Indicators
The diagnostic LEDs located on the front panel of the industrial switch provide real-time information of operation and
status. The following table provides the description of the LED status and their meanings for the switch.
LED
Status
Meaning
Green
Power 1 is active
OFF
No power inputs
Green
Power 2 is active
OFF
No power inputs
Red
Power input 1 or 2 is inactive
OFF
Power 1 & Power 2 are both active or no power inputs
PWR1
PWR2
Fault
Upper
LED
P9, P10 (RJ-45)
Lower
LED
Link/Active
(P9, P10)
P1 ~ P8
(Green)
P1 ~ P8
(Yellow)
Green
Connected to network
Blinking
Networking is active
OFF
Not connected to network
Green
The port is operating at speed of 1000M
OFF
The port is disconnected or not operating at speed of 1000M
Green
SFP port is linking
Blinks
Data is transmitting or receiving
OFF
Not connected to network
Green
Connected to network
Blinking
Networking is active
OFF
Not connected to network
Yellow
Ethernet port full duplex
Blinking
Collision of packet occurs
OFF
Ethernet port half duplex or not connected to network
Green
A powered device is connected utilizing Power over Ethernet on
the port
OFF
No device is connected or power forwarding fails
FWD (P1 ~ P8)
Manual Documentation Number: EIRP410-2SFP-T-0912m
5
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Ports
RJ-45 ports
The RJ45 copper ports support auto MDI/MDIX operation. This feature allows network connections to computers, servers, or
other switches using straight-through or crossover cables (See Figure below). Straight-through cable connections: pins 1, 2, 3
and 6, at one end of the cable, are connected straight-through to pins 1, 2, 3 and 6 at the other end of the cable. The table below
shows the 10BASE-T/100BASE-TX MDI and MDI-X port pin outs.
Manual Documentation Number: EIRP410-2SFP-T-0912m
6
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Cross Over Cable Schematic
Manual Documentation Number: EIRP410-2SFP-T-0912m
7
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
2 Mini-GBIC combo port
2 auto-detect combo Giga ports — RF45 or fiber. The gigabit Ethernet ports are shared with the mini-GBIC ports. RJ45
UTP (Gigabit Ethernet) ports can operate in half/full-duplex modes and work at speeds of 10/100/1000Mbps that support
auto-sensing technology to enable each port to detect the connecting speed. The mini-GBIC port is a socket for a miniGBIC (SFP) fiber transceiver.
Cabling
•
Use four twisted-pair, Category 5e or above cabling for RJ-45 port connection. The cable between the switch and
the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
•
Use the mini-GBIC ports to uplink to another switch by inserting the mini-GBIC (SFP) transceiver.
To connect the transceiver and LC cable, please follow the steps shown below:
First, insert the transceiver into the SFP module. Notice that the triangle mark is the bottom of the module.
Figure 2.8: Transceiver to the SFP module
Manual Documentation Number: EIRP410-2SFP-T-0912m
8
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Figure 2.9: Transceiver Inserted
Second, insert the fiber cable LC connector into the transceiver.
Figure 2.10: LC connector to the transceiver
To remove the LC connector from the transceiver, press the upper side of the LC connector to release from the
transceiver and pull it out.
Manual Documentation Number: EIRP410-2SFP-T-0912m
9
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Figure 2.11: Remove LC connector
Second, push down the metal loop and pull the transceiver out by the plastic handle.
Figure 2.12: Pull out from the transceiver
Manual Documentation Number: EIRP410-2SFP-T-0912m
10
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Wiring the Power Inputs
Wiring the Fault Alarm Contact
The fault alarm contact wired to pins 3 and 4 of the terminal block connector as the picture shows below. When the wires
are inserting the connected device will detect the fault status. The fault status includes power failure or port link failure.
Once one of the mentioned states occur an open circuit will exist. An application example for the fault alarm contact is
shown on the next page:
Note
The wire gauge for the terminal block should be in the range between
12-24 AWG.
Manual Documentation Number: EIRP410-2SFP-T-0912m
11
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Manual Documentation Number: EIRP410-2SFP-T-0912m
12
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Mounting Installation
DIN-Rail Mounting
The DIN-Rail is installed at the factory and maybe removed if needed.
Rear Panel of the switch
DIN-Rail
1.
First, insert the top of the DIN-Rail into the track.
13
Manual Documentation Number: EIRP410-2SFP-T-0912m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
2.
Lightly push the DIN-Rail into the track.
3.
Check the DIN-Rail to insure proper fit.
4.
To remove the industrial switch from the track, reverse steps above.
Manual Documentation Number: EIRP410-2SFP-T-0912m
14
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Wall Mount Plate Mounting
1.
Remove the DIN-Rail from the industrial switch.
2.
Install the wall mount plate on the rear panel of the industrial switch.
Manual Documentation Number: EIRP410-2SFP-T-0912m
15
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Network Application
This segment provides the samples to help user have more actual idea of industrial switch application. For a sample application
of the industrial switch, see the figures below.
Manual Documentation Number: EIRP410-2SFP-T-0912m
16
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Troubleshooting
•
Verify that you are using the appropriate power supply adapter. Do not use the power adapter with DC output higher than
the power rating of the device.
•
Select the proper UTP/STP cable to construct your network. Use unshielded twisted-pair (UTP) or shielded twisted-pair
(STP) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps connections, 100Ω Category 5 cable for
100Mbps connections. Insure the length of any twisted-pair connection does not exceed 100 meters (328 feet).
•
Diagnosing LED Indicators: The Switch can be easily monitored through panel LED’s. The LED’s will provide an easy
way of detecting power or communication problems.
•
If the Industrial switch LED indicators function normal and the connected cables are correct but the packets still cannot
transmit, please check your system’s Ethernet devices’ configuration or status. The Ping test is a common method to
check Ethernet devices connections on the network.
Manual Documentation Number: EIRP410-2SFP-T-0912m
17
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Technical Specification
Standard
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX/FX
IEEE802.3ab 1000Base-T
IEEE802.3z Gigabit fiber
IEEE802.3x Flow Control and Back Pressure
IEEE802.3af Power over Ethernet
Protocol
CSMA/CD
Transfer Rate
14,880 pps for 10Base-T Ethernet port
148,800 pps for 100Base-TX/FX Fast Ethernet port
1,488,000 pps for Gigabit Fiber Ethernet port
Packet Buffer
1Mbits
MAC address
8K MAC address table
LED
8 ports 10/100TX : Link/Activity (Green), Full duplex/Collision
(Yellow), Power Feeding (Green)
Giga port: Link/Activity (Green)
Per unit: Power 1 (Green), Power 2 (Green), Fault (Red)
Network Cable
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5, 5e cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/5E cable
EIA/TIA-568 100-ohm (100m)
1000Base-TX: 2-pair UTP/STP Cat. 5E cable
EIA/TIA-568 100-ohm (100m)
Optical cable
Distance:
Multi mode:
0 to 5 km, 1300 nm (50/125 μm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125 μm, 500 MHz*km)
Single mode:
0 to 40 km, 1310 nm (9/125 μm, 3.5 PS/(nm*km))
0 to 80 km, 1550 nm (9/125 μm, 19 PS/(nm*km))
Manual Documentation Number: EIRP410-2SFP-T-0912m
18
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Min. TX Output:
Multi mode: -20 dBm
Single mode: 0 to 40 km, -5 dBm; 0 to 80 km, -5 dBm
Max. TX Output:
Multi mode: -14 dBm
Single mode: 0 to 40 km, 0 dBm; 0 to 80 km, 0 dBm
Sensitivity:
-36 to -32 dBm (Single mode); -34 to -30 dBm (Multi mode)
Back-plane (Switching
Fabric)
5.6Gbps
Packet throughput
ability
8.3Mpps at 64bytes
Power Supply
External Power Supply: DC 48V
Redundant power DC 48V with connective removable terminal block
Power Consumption
140 Watts (maximum)
Install
DIN rail kit and wall-mount ear for DIN-type cabinet install and wall
mounting
Operating Temperature
-40oC ~ 75oC (Wide Operating Temperature model)
-10oC ~ 60oC (standard model)
Operating Humidity
5% to 95% (Non-condensing)
Storage Temperature
-40oC to 85oC
Case Dimension
IP-30, 72 mm (W) x 105 mm (D) x 152mm (H)
EMI
FCC Class A
CE EN61000-4-2/3/4/5/6/8/11/12
CE EN61000-6-2
CE EN61000-6-4
Manual Documentation Number: EIRP410-2SFP-T-0912m
19
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Safety
UL
cUL
CE/EN60950-1
Stability testing
IEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Manual Documentation Number: EIRP410-2SFP-T-0912m
20
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com