EcoQuest Fresh Air Owner's Manual

Add to My manuals
16 Pages

advertisement

EcoQuest Fresh Air Owner's Manual | Manualzz

65-00087-004 REV 02_04

FA SP-ENG OM - 02_04

OWNERS MANUAL

Installation

Operation

Specifications

Features

Maintenance

Warranty

INTRODUCTION

Congratulations, you have purchased one of the most effective, technologically advanced air purifiers available. Your new Fresh Air by EcoQuest is designed to provide years of trouble-free, low maintenance operation. Be sure to read and follow all service procedures outlined in this owner’s manual and to use only genuine EcoQuest replacement parts available from your

EcoQuest Dealer.

If you have any questions concerning this or any EcoQuest product, contact your EcoQuest Dealer.

Please record the name and phone of your EcoQuest Dealer:

Name ________________________________________________

Phone________________________________________________

Please record the serial number of your Fresh Air by EcoQuest:

Serial # ______________________________________________

2

To reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter the plug in any way.

CONTENTS

Inspection & Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Your New Fresh Air by EcoQuest: . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Settings and Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Maintenance and Service Reminders . . . . . . . . . . . . . . . . . . . . . . . .7

LCD Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

General Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Placement of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Optional EcoHelp Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Removing the Lint Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Removing the Purifier Plate & Catalytic Screen . . . . . . . . . . . . . .11

Removing the UV Bulb and Starter . . . . . . . . . . . . . . . . . . . . . . . . .11

Installing the UV Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Installing Catalytic Screen & Purifier Plate . . . . . . . . . . . . . . . . . . .12

Installing the Lint Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Check out the Online Owners Manual: http://www.ecoquestintl.com/freshairusaom

INSPECTION & INSTALLATION

1. Remove protective packaging.

2. Remove unit from shipping carton.

3. Remove all protective materials.

4. Check for shipping damage and loose or broken parts.

5. Read Owners Manual thoroughly prior to installation.

6. Install batteries in remote.

7. Determine placement location for the unit (See “Placement of

Unit” on page 9), plug the unit into a 110 volt outlet.

8. Be sure the main power switch (on back of unit - see page 5) is in the ON position.

9. Using either the remote control or the Power button, turn the unit ON. The display should look similar to below.

Fan Speed Purifier Setting

Purifier Coverage

OPERATION

1. Adjust the fan speed to your preference keeping in mind that higher fan speeds will give better results.

2. Set the purifier controls anywhere from zero up to the total area of the indoor environment.

Do not set the area indicated by the purifier above the square footage

(or square meters for international models) of the indoor area.

3. To operate the sanitize feature, press the sanitize button until the desired time is reached (2, 4, 6, or 8 hours). The unit will display SANITIZE and the remaining time in hours and minutes (see below). Make sure the area is unoccupied before using the sanitizer. To interupt the sanitize feature before the timer reaches zero, press the Purifier On/Off button.

Fan Speed (Max) Sanitize Mode

Time Remaining

NORMAL MODE: The unit’s display shows the fan speed (low to high), the purifier setting (1 bar to 12 bars), and the purifier coverage in square feet for

U.S. models and square meters for international units.

SANITIZE MODE: The unit’s display will change when the Sanitize function is active. The fan will show maximum and SANITIZE will replace the purifier setting. The amount of time remaining will depend on how long you have selected for the Sanitize function to operate. The colon (:) will flash to indicate time being count down.

3

4

Electrical:

• 100 volt 50/60hz, 110 volt 60 hz, 220/240 volt 50/60 hz depending on model

• 90 watts power consumption

• 24 to 30 KV, 20-30 Khz ion generation pulsator

• Fixed 6 KV DC needle ion generator

Mechanical:

• 400 CFM fan

Size:

• Dimensions: 12” high x 9” wide x 12” deep

• Weight: 16 pounds

Purification Plate Output:

• 0-360 mg of ozone per hour

Coverage:

• Covers a range of 250 square feet* to 3000 square feet**

* Depends on variables such as severity and frequency of pollution, humidity and temperature

Warranty:

• Length of warranty will vary depending on model

See warranty card for specific details

* 250 Sq. Ft. = 23 Sq. Meters **3000 Sq. Ft. = 279 Sq. Meters

YOUR NEW FRESH AIR BY ECOQUEST:

• Eliminates smoke, odors, and tobacco smoke.

• Sanitize feature kills mold, mildew, and bacteria.

• UVC light helps kill airborne germs as they pass through the unit.

• Removes odors from your home, office, car, boat, RV, etc.

• Improves the quality of air indoors

• Helps control additional dust and dander when an optional

EcoHelp filter is properly installed.

• Customizable to your environment using either the included remote or the controls on the front of the unit.

• IntelliAir™ Technology alerts you when normal maintenance needs to be performed or service is required.

WARNING! - Do not operate this unit without the lint screen AND back cover installed.

CAUTION! - The sanitizer feature of this unit is to be operated in unoccupied areas only.

CAUTION! - Disconnect power cord before servicing.

100 & 110 volt models - use 1.6 Amp slow blow fuse.

220/240 volt models - use 1.0 Amp slow blow fuse.

PE

Location for Protective Earth Line.

UNIT FEATURES

Back of Unit /

Rear Access

Removable

Grill

Controls

LCD Display

Infrared Window

• Five Speed Fan

• Adjustable Purifier control

• LCD Display

• Sanitizer Function w/ adjustable digital timer

• IntelliAir™ Maintenance Reminders

• IntelliAir™ Service Alerts

• Remote Control or Manual Operation

• Computer style cord

• Uses Standard household current

• Carbon-impregnated lint screen

• Washable Ecotech Purification Plate

• Washable Photocatalytic Process Screen

• Replaceable Gemicidal UV Lamp

• Optional EcoHelp HEPA-type filtration

Main Power

Switch

Fuse

Power Cord

Receptacle

5

SETTINGS AND ADJUSTMENTS

Fresh Air by EcoQuest can be turned on or off and adjusted using either the included remote or the control panel on the front of the unit. With the exception of the Reminder Reset button, both the remote and the control panel buttons have the same functions.

Fan UP

Reminder

Reset

Purifier UP

Sanitizer

Purifier ON/OFF

Power ON/OFF

Fan DOWN Purifier DOWN

POWER ON/OFF

Remote Operation LED

Sanitizer ON

Fan UP

Power

Sanitize

Purifier ON/OFF

Purifier UP

Purifier

Fan

Purifier

On / Off

Purifier

Fan

Purifier DOWN

Fan DOWN

Battery compartment (2 AAA)

6

POWER

Turns the unit ON and OFF. Works only when the Main

Power switch (in back of unit) is turned on.

FAN UP / FAN DOWN

Adjusts the five speed fan.

PURIFIER UP / PURIFIER DOWN

Sets the purifier level for the indoor area. The level is indicated by both a horizontal bar graph and square footage for U.S. models (or square meters for international models).

PURIFIER ON/OFF

Turns the purifier function on and off.

SANITIZER

Turns on and adjusts the timer for the sanitizer function. Each press of the Sanitizer button will increase the time by two hours, up to eight hours, then OFF.

REMINDER RESET

(CONTROL PANEL ONLY)

Clears the maintenance reminders after performing routine maintenance.

LCD DISPLAY

LCD SCREEN

The LCD Screen is used to display all current settings as well as any maintenance reminders and service messages.

Fan Speed Purifier Setting

Purifier Coverage

Reminders (normally blank - reminders appear here when unit needs maintenance)

LCD SCREEN BACKLIGHT

As adjustments are being made, the LCD screen backlight will brighten and the settings on the screen will change. After 15 seconds without change, the backlight will return to normal.

If a maintenance reminder or a service reminder appears, the backlight will brighten and stay bright until the Reminder Reset button is pressed or the service problem is corrected.

RESETTING THE REMINDERS

The only reminder you need to reset is the PERFORM MAINTENANCE reminder (after performing maintenance, press the Reminder Reset button and the screen will display CLEARED, then clear the message).

All the other service reminders will clear automatically once the unit has been turned off and back on and the problem has been corrected.

MAINTENANCE AND SERVICE REMINDERS

PERFORM MAINTENANCE

(approx. every 30 days)

• Vacuum Lint Screen

• Clean Purifier Plate

• Clean the Catalytic Screen

• Vacuum Front and Rear Grill openings

Be sure to press the Reminder

Reset button to clear the reminder following regular maintenance

INSTALL PLATE

The purifier plate is missing or installed incorrectly

• Install or Re-install purifier plate correctly

REPLACE PLATE

The purifier plate is not functioning properly.

• Replace the old purifier plate with a new purifier plate (available from your EcoQuest Dealer)

REPLACE LAMP

The germicidal UV lamp is no longer working correctly

• Replace the UV lamp and starter (new lamps and starters are available from your EcoQuest Dealer)

SEE PAGES 10 - 13 FOR REMOVAL AND INSTALLATION INSTRUCTIONS

7

GENERAL MAINTENANCE

Periodic maintenance is required to insure that your Fresh Air by

EcoQuest operates properly. The unit will display a PERFORM

MAINTENANCE reminder when it is time to perform regular maintenance. If you are operating your unit in a severely polluted environment, cleaning of the unit, purifier plate, and catalytic screen should be done more frequently. Shown here are basic procedures that should be carried out to keep your unit running at top performance.

CAUTION: Unplug the unit before performing any maintenance procedures.

Cleaning the Case:

Wipe the unit with a soft cloth dampened with water. Do not use chemicals or solvents. Vacuum the front and rear grills periodically to remove any lint buildup.

Rear lint-screen / Catalytic Screen cleaning:

You have two options to clean the lint screen and catalytic screen:

1. When visibly dirty, simply remove the rear lint screen and the catalytic screen from the unit (see pages 10 - 13) and, with a hand-held vacuum, remove the heavy particulate from both.

This method will extend the life of the filter and ensure proper function of the catalytic screen.

- OR -

8

2. When visibly dirty, remove the rear lint screen and catalytic screen from the unit (see pages 10 - 13) and wash in hot water, brushing gently with a toothbrush to remove particulate. Allow to dry prior to re-installing. Note: do not use soap - it will damage the carbon material in the lint screen. If an EcoHelp filter has been installed, replace if necessary - do not wash.

Rear lint-screen replacement:

Contact your EcoQuest Dealer for replacement lint screens.

Purifier Plate:

Remove the rear filter (see pages 10 - 13). Carefully remove the

Ecotech purifier plate from the card cage by grasping the middle of the edge nearest to you, and slowly pull it straight out.

Clean the purifier plate with hot water and EcoQuest’s ecoH cleaner (following the glass cleaner instructions on the package) or you can use ammonia and water. Dry completely using a hair dryer if necessary. Reinstall purifier plate. Be sure to check that the electrical tabs are in contact with the metal screens on the plate.

The unit will display a REPLACE PLATE message if the purification plate needs to be replaced.

Changing the UV Lamp

The UV lamp should be changed when REPLACE LAMP appears on the display. To change the lamp follow the instructions on pages 10 - 13.

Changing the fuse:

The fuse may be accessed by unplugging the cord from the back of the unit and gently pulling the fuse holder straight out.

100 & 110 volt models - use 1.6 Amp slow blow fuse.

220/240 volt models - use 1.0 Amp slow blow fuse.

OPTIONAL ECOHELP FILTER

For removal of additional dust and allergens, your Fresh Air by

EcoQuest will accommodate an optional EcoHelp filter. The

EcoHelp filter replaces the standard lint screen and is completely covered when the unit is properly assembled. See page 13 for filter installation instructions. Contact your EcoQuest Dealer to order an EcoHelp filter.

PLACEMENT OF UNIT

Place the unit as high as possible to insure complete purification.

(On top of a bookshelf, high cabinet, etc.)

Suggested locations, listed in the order of preference:

1. Nearest the source of the worst pollution.

2. Near a cold-air return to thoroughly circulate clean air throughout the area.

3. In the area most heavily used to achieve maximum benefit.

Note:

• The rear of the unit should always have at least one inch of open area to allow unrestricted airflow.

• Be sure the power cord is not accessible to small children to prevent injury.

9

10

REMOVING THE LINT SCREEN

1. Unplug unit.

1

2. Remove the two (2)

2

To Remove:

Lint Screen

follow steps 1 - 5

Purifier Plate

follow steps 1 - 6

Catalyzer Screen

follow steps 1 - 7

UV Bulb

follow steps 1 - 10

5. Remove the top of the lint screen holder and the lint

5 back and lifting up and out.

4 the top of the lint screen holder.

To remove the purification plate, continue to step 6.

For installation of the lint screen or

EcoHelp filter, go to page 13.

WARNING: DO NOT OPERATE Fresh Air by EcoQuest without the lint screen and back cover properly installed.

REMOVING THE PURIFIER PLATE & CATALYTIC SCREEN REMOVING THE UV BULB AND STARTER

6. To remove the purification plate, grasp edge of plate in

6

NOTE: If the plate is difficult to remove, gently press down on the lower metal contact tab.

7. To remove the catalytic screen, grasp the frame and

7

TIP: Hot water and ammonia work well to clean your

Ecotech Purification Plates, but did you know that ecoH

Household Cleaner will clean your purification plates without the fumes or smell of ammonia. Ask your

EcoQuest Dealer for more information.

lead wires attached to

8

8. Disconnect the two (2) the purifier plate cage.

10

10. Rotate starter and lift to remove.

9

9. Loosen two (2) screws holding the plate cage. Slide the cage forward, lift and remove.

11

11. Rotate UV Bulb 1/4 turn, lift out of holders, and remove from unit.

11

INSTALLING THE UV LAMP

1

1. Insert UV bulb into holder then rotate to lock into place.

NOTE: Do not touch glass areas of

UV bulb. To install, hold bulb by ceramic ends only.

2

2. Replace starter and turn to lock.

INSTALLING CATALYTIC SCREEN & PURIFIER PLATE

5. Replace catalytic screen by gently inserting into the large

5

To Install:

Lint Screen or

EcoHelp Filter

follow steps 7 - 11

Purifier Plate

follow steps 6 - 11

Catalytic Screen

follow steps 5 - 11

UV Bulb

follow steps 1 - 11

6. Gently insert the purifier plate

6 cage) until it stops.

12

3

3. Replace cage by lowering and sliding back into place. Tighten two (2) screws securely.

4

4. Connect the two (2) lead wires attached to the purifier plate cage.

INSTALLING THE LINT SCREEN

the top of the lint screen

7. Replace lint screen and

7 holder at the same time.

For disassembly instructions see pages 10 - 11.

11. Reinstall the power cord.

11

8. Be sure the lint screen

8 depresses the metal tab.

9. Replace two (2) lint screen

9

10. Replace two (2)

10

When installing the purification plate, be sure the metal tabs are making contact with the screen on each side of the plate.

WARNING: DO NOT OPERATE

Fresh Air by EcoQuest without the lint screen and back cover properly installed.

13

TROUBLESHOOTING

Indicators of Operation

When the unit is on the LCD display will show the fan setting, purifier setting, and square footage. If the unit is in sanitizer mode, it will display SANITIZE and the hours and minutes remaining.

Troubleshooting - What to look for first.

1. I have plugged in the unit, turned “on” the main power switch, pressed the ON button on the remote (or the unit) and nothing happens…what's wrong?

• Make sure the power cord is inserted completely into the receptacle on the back of the unit.

• Make sure the electrical outlet is capable of providing power to the unit.

• Check the lint screen located at the back of the machine to ensure that the safety switch activator clip depresses the safety switch.

• Check to see if the proper fuse is installed and that it is operational.

14

2. The fan is operating but the Ecotech Purifier Plate is not working…what's wrong?

• The unit will diplay a REPLACE PLATE message.

• Check the Ecotech purifier plate for serviceability. If it is cracked or broken, the purifier plate will require replacement.

Ensure maintenance procedures required for the purifier plate have been performed according to the "Maintenance" section of this Owner's Manual. Order new plates from your EcoQuest

Dealer.

• Electrical stainless steel contacts are not contacting the screen portion of the purifier plate. Unplug and inspect the unit for any loose connections.

• Do not attempt to disassemble the unit, this will void the warranty of the product.

3. The Ecotech Purifier Plate is making a noise, has a burning smell, and/or appears to arc or spark. What is the problem?

• The purifier plate is most likely cracked. The unit will display a

REPLACE PLATE message. Refer to the answers for question # 2, as it would apply to this question also.

4. The UV lamp is not functioning / I’m getting a “Replace Lamp” message.

• Check lamp for proper installation.

• Replace UV Lamp.

PLEASE NOTE: If unit has been recently transported check lamp for proper installation, remove Lamp and reinstall.

5. What are the most typical application problems?

• Symptom: A belief that the proper equipment is placed in the environment and the equipment appears unsuccessful.

Problem: Lack of air movement, improper placement of the unit.

• Symptom: Strong odors still remain within the environment after placement.

Problem: Purifier setting is too low or improper placement of the unit.

• Symptom: A strong odor of ozone is present within the environment.

Problem: Too much ozone accumulation within the environment as a result of improper purifier control setting, and / or lack of air movement.

• Symptom: Visual haze of smoke and / or particulate remain within the environment.

Problem: Lack of ionization and / or air movement.

6. How can I tell if the UV lamp is functioning?

• The UV lamp will produce a glow that is visible through the front grill under low light conditions

CAUTION: Do not look directly at the glowing lamp.

7. Unit does not operate -

• Is the unit plugged in?

• Are you sure the outlet is active?

• Is the main power switch turned on?

• Is the rear lint screen installed properly to depress the safety switch downward?

• Does the fuse need to be replaced?

8. Air flow is restricted or reduced -

• Is the unit properly placed away from objects that may obstruct air flow?

• Are the lint screen (or EcoHelp filter) and front grill housing clean?

• Is the catalytic screen clean?

If your unit fails to operate properly after performing trouble-shooting, contact your EcoQuest Dealer for further assistance, contact EcoQuest at the address located on the front of the manual, or visit www.EcoQuest.com for additional support.

15

16

WARRANTY INFORMATION

This product is of solid state construction and is warrantied by

EcoQuest International

310 T. Elmer Cox Drive

Greeneville, TN 37743

to the original purchaser, depending on model, to be free from defect in materials and workmanship for a limited time.

Length of warranty will vary depending on model.

See warranty card for specific details.

If you have any questions concerning your Fresh Air by EcoQuest, please see your local EcoQuest Dealer.

For help, visit www.EcoQuest.com.

EcoQuest International

310 T. Elmer Cox Drive

Greeneville, TN 37743

Did you forget to register your Fresh Air by EcoQuest?

By registering, you’ll activate your warranty, and your privacy is guaranteed.

Just fill out your warranty card and drop it in the mail.

310 T. Elmer Cox Drive

Greeneville, TN 37743

423.638.7246

www.EcoQuest.com

Copyright © 2003 EcoQuest International. All rights reserved

advertisement

Key Features

  • Eliminates smoke, odors, and tobacco smoke
  • Improves the quality of air indoors
  • Sanitize feature kills mold, mildew, and bacteria
  • UVC light helps kill airborne germs
  • Removes odors from your home, office, car, boat, RV, etc.
  • Helps control additional dust and dander when an optional EcoHelp filter is properly installed
  • Customizable to your environment using either the included remote or the controls on the front of the unit

Related manuals

Frequently Answers and Questions

What is the power consumption of the EcoQuest Fresh Air?
90 watts
What is the size of the EcoQuest Fresh Air?
12” high x 9” wide x 12” deep
What is the weight of the EcoQuest Fresh Air?
16 pounds
What is the ozone output of the EcoQuest Fresh Air?
0-360 mg per hour
What is the CFM of the EcoQuest Fresh Air?
400 CFM