Installation and Operation Manual

Silence Sentinel

®

Basic

Manual update: 03/07/2011

Firmware version: PIC1.07 or greater.

If you need a firmware upgrade, contact Broadcast Tools®

No part of this document may be reproduced or distributed without permission.

ALL SPECIFICATIONS AND FEATURES FOR THIS PRODUCT ARE SUBJECT TO

CHANGE WITHOUT NOTICE

NOTE: We recommend the use of Firefox or Safari for Windows as your browser.

Due to the dynamic nature of product design, the information contained in this document is subject to change without notice. Broadcast Tools, Inc., assumes no responsibility for errors and/or omissions contained in this document. Revisions of this information or new editions may be issued to incorporate such changes.

Broadcast Tools® is a registered trademark of Broadcast Tools, Inc.

tiny TOOLS™ is a trademark of Broadcast Tools, Inc.

All Sentinel® labeled products are registered trademarks of Broadcast Tools, Inc.

Copyright® 1989 - 2011 by Broadcast Tools, Inc. All rights reserved.

No part of this document may be reproduced or distributed without permission.

Visit www.broadcasttools.com for important product update information.

Silence Sentinel ® Basic Installation and Operation Manual

Table of Contents

Section Title Page #

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Who to Contact for Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Features/Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

UPS Standby Power System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Power, 7.5 VDC connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Cable Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Connecting your equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

K1 & K2 relay connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Remote “Disable/Alarm Reset” input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Power / Heart beat LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Programming Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Dipswitch Setup Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Delay timing setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Restore timing setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Trip (input sensitivity) level setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Delay Resolution setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Stereo / Dual monaural (Independent) setup . . . . . . . . . . . . . . . . . . . . . . . . . . 7

K2 pulse length setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Operational Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Front panel LED and disable switch descriptions . . . . . . . . . . . . . . . . . . . . . . 8

Stereo Mode operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Dual Monaural (Independent) Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . 8

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Functional Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix

Fractional Schematic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix

Configuration and wiring sheet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix

Usage Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix

WEBSITE:

Visit our web site for product updates and additional information.

e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

CONTENTS

2

Silence Sentinel ® Basic Installation and Operation Manual

INTRODUCTION

CAUTION!

Thank you for your purchase of a Broadcast Tools® “Silence Sentinel® Basic”

(referred to as the Silence Sentinel® Basic throughout this manual). We’re confident that this product will give you many years of dependable service. This manual is intended to give you all the information needed to install and operate the Broadcast

Tools® “Silence Sentinel® Basic”.

SAFETY INFORMATION

Broadcast Tools®

Products, as with any electronic device, can fail without warning.

Do not use this product in applications where a life threatening condition could result due to failure.

Only qualified technical personnel should install Broadcast Tools products. Any attempt to install this device by a person who is not technically qualified could result in a hazardous condition to the installer or other personnel or damage Broadcast

Tools product or other equipment. Please ensure that proper safety precautions have been taken before installing this device. If you are unfamiliar with this type of equipment, please contact a properly qualified engineer to handle the installation and setup of the Broadcast Tools product.

Broadcast Tools, Inc., is unable to support NON-Broadcast Tools software, hardware or NON-Broadcast Tools computer/hardware/software problems. If you experience these problems, please research your hardware/software instruction manuals or contact the manufacturers technical support department.

NOTE:

This manual should be read thoroughly before installation and operation.

WHO TO CONTACT FOR HELP

If you have any questions regarding your product or you need assistance, please contact your distributor from whom you purchased this equipment.

If you would like more information about Broadcast Tools® products, you may reach us at:

WEBSITE:

Visit our web site for product updates and additional information.

Broadcast Tools, Inc.

131 State Street

Sedro-Woolley, WA 98284-1540 USA

Voice: 360.854.9559

Fax: 866.783.1742

Internet Home Page: www.broadcasttools.com

E-mail: [email protected]

THANK YOU FOR CHOOSING

BROADCAST TOOLS® BRAND PRODUCTS!

e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

SECTION TITLE

3

Silence Sentinel ® Basic Installation and Operation Manual

Product Overview

The Broadcast Tools® Silence Sentinel® Basic is a basic stereo silence sensor designed to monitor any stereo or two independent monaural sources and generate alarms when silence is detected, but doesn’t incorporate an audio switcher. Features include: front panel, remote control and relay monitoring; plug-in euroblock screw terminals; “Plug & Play” (NO POTS) installation; dipswitch selection of the following; silence detection of -20, -25, -30 and 35dB below zero reference; precise time delay from OFF to 5 minutes in 2 or 20 second increments; restore delay timing of OFF, 5, 30 and 90 seconds and two SPDT alarm relays with LED indicators.

The Silence Sentinel® Basic may be set on a desktop, mounted on a wall or optional RA-1 rack shelf for mounting up to four units in 1-RU.

Features/Benefits

* May be configured for stereo or dual independent monaural operation.

* Left and right valid audio and alarm LED indicators.

* Dipswitch selection of silence detection of -20, -25, -30 and -35dB below zero reference.

* Dipswitch selection of time delay from OFF to 5 minutes in 2 or 20 seconds increments.

* Dipswitch selection of restore timing delay from OFF, 5, 30 and 90 seconds.

* Two independent SPDT alarm relays and LED indicators.

* Active balanced stereo input.

* Front panel and remote “Disable/Alarm Reset” switch with LED indicator.

* Front Panel Power/heartbeat LED.

* Plug-in euroblock screw terminals, mating plugs supplied.

* Domestic power supply included.

* The unit may be set on a desktop, mounted on a wall or optional RA-1 rack shelf for mounting up to four units in 1-RU with user supplied Velcro.

Installation Guidelines

WEBSITE:

Visit our web site for product updates and additional information.

Inspection

Please examine your Silence Sentinel® Basic for any damage that may have been sustained during shipping. If any is noted, please notify the shipper immediately and retain the packaging for inspection by the shipper. The package should contain the

Silence Sentinel® Basic, this manual and/or CD and the 7.5 VDC @ 1 amp wall transformer. Manuals may also be downloaded from our web site.

Mounting

Mount the Silence Sentinel® Basic where it will be visible and rear panel accessible.

The Silence Sentinel® Basic may be set on a desktop, mounted on a wall or optional RA-1 rack shelf for mounting up to four units in 1-RU using user supplied Velcro.

e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

INSTALLATION

4

Silence Sentinel ® Basic Installation and Operation Manual

Surge Protection

CAUTION!

The Silence Sentinel® Basic has built-in resistance to voltage changes; we recommend that you use a power surge protector or line conditioner on the incoming AC line. Lightning strikes and/or other high voltage surges may damage your Silence

Sentinel® Basic and connected equipment if it is not properly protected. For lightning protection devices, check out www.polyphaser.com and www.itwlinx.com.

UPS Standby Power System

We recommend that you connect your Silence Sentinel® Basic to a UPS system. A

UPS helps minimize the risk to the Silence Sentinel® Basic and provides power during a power outage.

Installation of the

Silence Sentinel® Basic in high RF environments should be performed with care. The station ground should be connected to the designated “GND” ground terminal.

POWER 7.5 VDC connector

This is the connector used to power the unit. Never use any type of power supply other than the specified power supply.

Cable Preparation

The Silence Sentinel® Basic interfaces to external equipment through removable euroblock screw terminals. The terminals accommodate wire sizes from 16 - 28

AWG solid or stranded wire. Before installing a wire, remove the euroblock screw terminal plug and turn each capture screw fully counterclockwise. Strip each conductor to a length of 0.25” and insert the conductor fully into the terminal. Turn the capture screw fully clockwise to secure the conductor. Verify that no bare wires are exposed.

Connecting your equipment

Connect the audio source (air monitor, etc) to J1, the left and right inputs. Audio inputs may be balanced or unbalanced. When using unbalanced sources, feed the + input and jumper the minus (–) input to GND. These inputs are labeled LT- and LT+ for the left channel and RT- and RT+ for the right channel. Observe proper stereo phasing.

When used in dual monaural (independent) mode, the left input is ONE and the right input is TWO.

NOTE: If the audio source is a tuner or receiver, be sure to feed the input(s) from the fixed output, such as the tape monitor outputs.

e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

INSTALLATION

5

Silence Sentinel ® Basic Installation and Operation Manual

K1 & K2 relay connections

External equipment to be controlled should be attached to the terminal J2 labeled

KxNO, KxCM and KxNC (where x is the control relay number) for relay 1 or 2.

NOTE: If mechanical latching relays are required, we suggest the Broadcast

Tools LR-5 (4PDT & SPST) mechanical latching relay.

Remote “Disable/Alarm Reset” input connection

The remote disable/alarm reset switch should be connected between the disable and ground terminals on J2. The remote disable/alarm reset input requires a sustained closure to ground. NOTE: If the front panel disable/alarm reset switch is engaged (unit disabled), then the remote input is disabled.

Power/HB LED

The flashing LED Indicates valid power and that the control processor is operating.

Programming Guidelines

DIPSwitch Setup

Locate dipswitch S1 on the front of the unit and follow the grid below.

Delay Time (SW1-9 ON) SW1-1 SW1-2 SW1-3 SW1-4 Restore SW1-5 SW1-6

Delay Time

OFF / Instant OFF OFF OFF OFF OFF/Instant OFF OFF

2 Sec (20 Sec)

4 Sec (40 sec)

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

5 seconds ON

30 seconds OFF

OFF

ON

ON 6 Sec (1 Minute) ON ON OFF OFF 90 seconds ON

8 Sec (1 Minute, 20 sec) OFF OFF ON OFF

10 Sec (1 Minute, 40 sec) ON OFF ON OFF

12 Sec (2 Minutes) OFF ON ON OFF

Delay SW1-9

Resolution

2 seconds

20 seconds

OFF

ON

Mode Select SW1-10

Stereo Mode * OFF

Dual monaural ON mode.

WEBSITE:

Visit our web site for product updates and additional information.

14 Sec (2 Minutes, 20 sec) ON ON ON OFF

16 Sec (2 Minutes, 40 sec) OFF OFF OFF ON

18 Sec (3 Minutes) ON OFF OFF ON

20 Sec (3 Minutes, 20 sec OFF ON OFF ON

22 Sec (3 Minutes, 40 sec) ON ON OFF ON

24 Sec (4 Minutes) OFF OFF ON ON

26 Sec (4 Minutes, 20 sec) ON OFF ON ON

28 Sec (4 Minutes, 40 sec) OFF ON ON ON

30 Sec (5 Minutes) ON ON ON ON

Trip Level SW1-7 SW1-8

- 20dB OFF OFF

- 25dB ON

- 30dB OFF

- 35dB ON

OFF

ON

ON

K2 Pulse length * JPR1

2 Second OFF

20 Seconds ON e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

PROGRAMMING

6

Silence Sentinel ® Basic Installation and Operation Manual

Delay timing setup

The delay period is the time between when valid audio fails and when an alarm is triggered. The Silence Sentinel® Basic time delay is set by the first four switches on SW1, along with dipswitch 9. SW1-9 provides TWO second resolution when

OFF. To provide longer time resolution, turn on SW1-9 which will provide 20 second resolution. The switches are set at the factory for a 2 second delay (SW1-1, ON factory default).

Restore timing setup

The restore period is the time between when valid audio returns and when the alarm is cleared. Restore time is set by SW1, switches 5 and 6. This function may be turned OFF by setting both switches OFF (factory default).

Trip (input sensitivity) level setup

The trip levels are referenced at zero. Switches 7 and 8 are used to set the stereo or dual monaural trip levels. The factory default is both switches OFF, (-20).

We recommend setting the trip level to -25 for most installations.

Delay Resolution setup

SW1-9 sets the delay timing for either 2 seconds or 20 seconds. Factory default is

(OFF) 2 seconds.

Stereo / Dual (Independent) monaural setup

SW1-10 determines stereo or dual monaural (Independent) operation. When this switch is OFF, (factory default) stereo operation is selected. With the switch ON, dual monaural (Independent) operation is selected.

K2 function pulse length setup

With a jumper over the ON position of JPR1, K2 generates a 20 second pulse. When the OFF position is selected, a 2 second pulse is set (Factory default). This is only operational with the unit in stereo mode. This function could be used to trigger an external AC power relay to reboot equipment. In dual monaural (Independent) mode, K1 is associated with input one and K2 is associated with K2.

NOTE: The front panel must be removed to access this jumper (refer to the configuration and wiring sheet) in the appendix. e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

PROGRAMMING

7

Silence Sentinel ® Basic Installation and Operation Manual

Operational Guidelines

Front panel descriptions

The front panel DIP switch setup functions are laid out using the grid on page SIX of the manual. The front panel disable switch is used to disable or reset an alarm condition. The switch is a latching type device. When engaged, the unit is disabled.

To remotely disable the unit, leave the front panel switch enabled (out) and apply a ground (sustained) to the remote disable input on the rear panel.

The LED indicators are described on the top cover label and in the appendix.

Stereo Mode operation

When the Silence Sentinel® Basic is “Enabled”, it will trigger in the absence of audio (see trip level setup) on either or both channels after the delay time has expired

(See delay dipswitch SW1-1 thru 4 and SW1-9) which will cause the following action:

1 - The front panel “OK LT” and/or “OK RT” audio LED’s will extinguish.

2 - The failed alarm led’s “ALM LT” and/or “ALM RT” and relay K1 will activate.

3 – K2 pulses for either 2 or 20 seconds.

Note: K2 will generate a pulse of a duration determined by JPR1.

When both channels return and the restore time delay has expired (if enable), the following action occurs:

1 – K1 opens.

2 - The front panel “OK LT” and “OK RT” audio LED’s will illuminate

3 - Either or both “ALM LT” or “ALM RT” led indicators will stay illuminated to provide history of the alarm until reset. To reset an alarm, press (pull the remote disable input to ground) in the disable (alarm reset) switch and then press again to release the switch.

Dual Monaural (Independent) Mode Operation

When the Silence Sentinel® Basic is enabled, it will trigger in the absence of audio

(see trip level setup) on each of the independent channels after the delay time has expired (See delay dipswitch SW1-1 thru 4 and SW1-9).

WEBSITE:

Visit our web site for product updates and additional information.

The Silence Sentinel® Basic when triggered will cause the following action:

1 - The failed “ALM LT1” and/or “ALM RT2” led(s) will illuminate.

2 - Either or both relays K1 and K2 will close.

When either audio channel returns, and the restore time delay has expired (if enabled), the following action occurs:

1 - Either or both relays (K1 and K2) will open.

2 -The failed “ALM LT1” and/or “ALM RT2” led indicators stay illuminated to provide history of the alarm. To reset an alarm, press (pull the remote disable input to ground) in the disable (alarm reset) switch and then press again to release the switch.

e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

OPERATION

8

Silence Sentinel ® Basic Installation and Operation Manual

Input Level: -15 to +24 dBu, 22 K ohm, balanced.

Silence Sense trip levels: -20, -25, -30 and -35dB below zero reference.

Alarm Delay: OFF to 5 minutes in 2 or 20 seconds increments.

OFF, 5, 30 and 90 seconds.

Restore Delay:

Disable/Enable Input:

Relays, K1 and K2:

Sustained closure to ground. Pulled up to 5

VDC.

Each relay with SPDT dry contacts, 30 VDC @

1 Amp.

Connectors:

Power supply:

Removable euroblock screw terminals.

7.5 VDC only @ 500ma or 1 Amp PS supplied.

2.1mm ID x 5.5mm OD coaxial connector.

Surge protected.

Operating Temperature: -40°F to +185°F (-40°C to +85°C)

Size: 6.18” x 3.70” x 1.42” (L,W,H)

Weight:

Options:

1.0 lb.

* CE certified universal input power supply.

* RA-1, 1-RU rack shelf. Note: User supplied

Velcro may be used to secure the product to the

RA-1 shelf.

WEBSITE:

Visit our web site for product updates and additional information.

e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

SPECIFICATIONS

9

Silence Sentinel ® Basic Installation and Operation Manual

LIMITED WARRANTY

The term “Buyer” as used in this document refers to and includes both (but only) (a) any person or entity who acquires such an item for the purpose of resale to others (i.e., a dealer or distributor of an item), and (b) the first person or entity who acquires such an item for such person’s or entity’s own use.

Broadcast Tools warrants to each Buyer of any item manufactured by Broadcast Tools that the item will be free from defects in materials and workmanship at the time it is shipped by Broadcast Tools if the item is properly installed, used and maintained.

EXCLUSIVE REMEDIES

If Broadcast Tools is notified, in writing, of a failure of any item manufactured by Broadcast Tools to conform to the foregoing Limited

Warranty within one (1) year following the date of the Buyer’s acquisition of the item, and if the item is returned to Broadcast Tools in accordance with Broadcast Tools’ instructions for confirmation by inspection of the defect (which at Broadcast Tools’ election may include, without limitation, a requirement that the Buyer first obtain a Return Authorization number from Broadcast Tools, that the Buyer furnish proof of purchase in the form of an invoice and/or receipt, and that the Buyer prepay all freight charges associated with any return of the item to Broadcast Tools using such freight service as Broadcast Tools reasonably may specify), Broadcast Tools will repair or replace the defective item, or will refund the purchase price paid by the Buyer for the item. Broadcast Tools shall have the exclusive right to choose between these alternative remedies.

NO OTHER WARRANTIES OR REMEDIES

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, BROADCAST TOOLS AND ITS SUPPLIERS DISCLAIM ALL OTHER

WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL-

ITY OR FITNESS FOR A PARTICULAR PURPOSE; AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF

ALL OTHER REMEDIES. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS,

WHICH VARY FROM STATE/JURISDICTION TO STATE/JURISDICTION.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, NEITHER BROADCAST TOOLS NOR ANY OF ITS SUPPLIERS

SHALL HAVE ANY LIABILITY FOR ANY SPECIAL, INCIDENTAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES WHATSO-

EVER (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES FOR LOST PROFITS, BUSINESS INTERRUPTION, LOSS OF DATA OR

INFORMATION, COST OF CAPITAL, CLAIMS OF CUSTOMERS, OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE

OF OR THE INABILITY TO USE ANY ITEM SUPPLIED BY BROADCAST TOOLS, EVEN IF BROADCAST TOOLS HAS BEEN

ADVISED OF THE POSSIBILITY OF SUCH DAMAGES HAVE ANY LIABILITY FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL,

EXEMPLARY OR PUNITIVE DAMAGES. THIS LIMITATION OF LIABILITY APPLIES WHETHER A CLAIM IS ONE ALLEGING

BREACH OF A CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT, FOR THE VIOLATION OF ANY STATUTORY DUTY,

THE FAILURE OF ANY LIMITED OR EXCLUSIVE REMEDY TO ACHIEVE ITS ESSENTIAL PURPOSE, OR ANY OTHER CLAIM OF

ANY NATURE. BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY

FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, THIS LIMITATION MAY NOT APPLY TO YOU.

Broadcast Tools, Inc.

131 State Street

Sedro-Woolley, WA 98284 • USA

360.854.9559 voice • 866.783.1742 fax [email protected] e-mail www.broadcasttools.com website e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

LIMITED WARRANTY

10

Silence Sentinel ®

SILENCE

Sentinel

®

Basic

Loss of Audio Detector – Audio Controlled Relay

Functional Diagram

(1) Left Audio Input

(2) Right Audio Input

GND

+

+

Control Processor and Stereo

Silence Detector

K1

K2

(1) Valid Left Audio “OK LT”

(2) Valid Right Audio “OK RT”

(1) Alarm Left “ALM LT”

(2) Alarm Right “ALM RT”

Power/Heartbeat “PWR/HB”

“DISABLED”

Disabled Local and

Remote Switch

1

11 Configuration DIP-Switches

11

7.5vdc external

Power Supply (supplied) PS

+5VDC

–5VDC

(Unit in Independent, Dual Monaural mode)

APPENDIX e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

Silence Sentinel ® Basic Installation and Operation Manual e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

APPENDIX

12

Silence Sentinel ® Basic Installation and Operation Manual e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742

APPENDIX

13

Silence Sentinel ® Basic Installation and Operation Manual e-mail: [email protected] voice:

360.854.9559 fax:

866.783.1742