Eizo RadiForce GX540-CL Installation manual

English
Deutsch
Important: Please read this “Instructions for Use”, and Installation Manual (on the
CD-ROM) carefully to familiarize yourself with safe and effective usage.
Please retain this manual for future reference.
•The latest "Instruction for Use” is available for download from our web
site: http://www.eizo.com
Wichtig:
Bitte lesen Sie diese „Gebrauchsanweisung“ und das separate
Installationshandbuch sorgfältig durch, um sich mit dem sicheren und
sachgemäßen Gebrauch des Produkts vertraut zu machen.
Bewahren Sie dieses Handbuch zum späteren Nachschlagen auf.
•„Gebrauchsanweisung“ steht Ihnen auf unserer Website zum Download
zur Verfügung: http://www.eizo.com
Mode d’emploi
Important : Veuillez lire attentivement ce « Mode d’emploi » ainsi que le Manuel
d’installation (tome séparé) afin de vous familiariser avec ce produit et de
l’utiliser efficacement et en toute sécurité.
Veuillez conserver ce manuel pour référence ultérieure.
•La dernière version du « Mode d’emploi » est à disposition pour
téléchargement sur notre site Web : http://www.eizo.com
设定手册
重要事项: 请仔细阅读本“使用说明书”和“安装手册”(单独卷),熟
悉安全和高效使用。请保留本手册,以备日后参考。
•最新“使用说明书”可在我们的网站上下载 :http://www.eizo.com
中文
Gebrauchsanweisung
Français
Instructions for Use
Monochrome LCD monitor
English
Instructions for Use
SAFETY SYMBOLS
This manual and this product use the safety symbols below. They denote critical information. Please read them
carefully.
WARNING
CAUTION
Failure to abide by the information in a
WARNING may result in serious injury
and can be life threatening.
Failure to abide by the information in a
CAUTION may result in moderate injury and/or
property or product damage.
Indicates an attention to be required. For example, the symbol
such as “the risk of electric shock”.
Indicates a prohibited action. For example, the symbol
such as “Do not disassemble”.
illustrates the hazard type
illustrates a particular prohibited action
Indicates a mandatory action that must be followed. For example, the symbol
notification of general prohibition such as “Grounding the unit”.
illustrates the
This product has been adjusted specifically for use in the region to which it was originally shipped. If operated
outside this region, the product may not perform as stated in the specifications.
No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
electronic, mechanical, or otherwise, without the prior written permission of EIZO Corporation.
EIZO Corporation is under no obligation to hold any submitted material or information confidential unless prior
arrangements are made pursuant to EIZO Corporation’s receipt of said information. Although every effort has been
made to ensure that this manual provides up-to-date information, please note that EIZO monitor specifications are
subject to change without notice.
2

PRECAUTIONS
• This product has been adjusted specifically for use in the region to which it was originally shipped. If the
product is used outside the region, it may not operate as specified in the specifications.
• To personal safety and proper maintenance, please read carefully this section and the caution statements on
the monitor.
Location of the Caution Statements
Symbols on the unit
Symbol
This symbol indicates
Main Power Switch:
Press to turn the monitor’s main power off.
Main Power Switch:
Press to turn the monitor’s main power on.
Power button:
Press to turn the monitor’s power on or off.
Alternating current
Alerting electrical hazard
CAUTION:
Refer to SAFETY SYMBOLS section in this manual.
PRECAUTIONS
3
English
●●IMPORTANT
WARNING
If the unit begins to emit smoke, smells like something is burning, or makes strange noises, disconnect all power connections immediately and contact your local EIZO representative for advice.
Attempting to use a malfunctioning unit may result in fire, electric shock, or equipment damage.
Do not open the cabinet or modify the unit.
Opening the cabinet or modifying the unit may result in fire, electric shock, or burn.
Refer all servicing to qualified service personnel.
Do not attempt to service this product yourself as opening or removing covers may result in fire, electric shock, or
equipment damage.
Keep small objects or liquids away from the unit.
Small objects accidentally falling through the ventilation slots into the cabinet or spillage into
the cabinet may result in fire, electric shock, or equipment damage. If an object or liquid falls/
spills into the cabinet, unplug the unit immediately. Have the unit checked by a qualified service
engineer before using it again.
Place the unit at the strong and stable place.
A unit placed on an inadequate surface may fall and result in injury or equipment damage. If the
unit falls, disconnect the power immediately and ask your local EIZO representative for advice.
Do not continue using a damaged unit. Using a damaged unit may result in fire or electric shock.
Use the unit in an appropriate location.
Not doing so may result in fire, electric shock, or equipment damage.
•
•
•
•
•
•
•
•
Do not place outdoors.
Do not place in the transportation system (ship, aircraft, trains, automobiles, etc.)
Do not place in a dusty or humid environment.
Do not place in a location where water is splashed on the screen (bathroom, kitchen, etc.).
Do not place in a location where the steam comes directly on the screen.
Do not place near heat generating devices or a humidifier.
Do not place in a location where the product is subject to direct sunlight.
Do not place in an inflammable gas environment.
To avoid danger of suffocation, keep the plastic packing bags away from babies and children.
Use the enclosed power cord and connect to the standard power outlet of your country.
Be sure to remain within the rated voltage of the power cord. Not doing so may result in fire or electric shock.
Power supply: 100-120/200-240Vac 50/60Hz
To disconnect the power cord, grasp the plug firmly and pull.
Tugging on the cord may damage and result in fire or electric shock.
The equipment must be connected to a grounded main outlet.
Failure to do so may result in fire or electric shock.
Use the correct voltage.
• The unit is designed for use with a specific voltage only. Connection to another voltage than specified in this
“Instructions for Use” may cause fire, electric shock, or equipment damage.
Power supply: 100-120/200-240Vac 50/60Hz
• Do not overload your power circuit, as this may result in fire or electric shock.
4
PRECAUTIONS
Handle the power cord with care.
English
• Do not place the cord underneath the unit or other heavy objects.
• Do not pull on or tie the cord.
If the power cord becomes damaged, stop using it. Use of a damaged cord may result in fire or
electric shock.
For the electrical safety, do not connect or disconnect the power cord in the presence of patients.
Never touch the plug and power cord if it begins to thunder.
Touching them may result in electric shock.
When attaching an arm stand, please refer to the user’s manual of the arm stand and install the unit
securely.
Not doing so may cause the unit to become unattached, which may result in injury or equipment damage. Before
installation, make sure that desks, walls, and others an arm stand is fixed on have adequate mechanical strength. When
the unit is dropped, please ask your local EIZO representative for advice. Do not continue using a damaged unit. Using
a damaged unit may result in fire or electric shock. When reattaching the tilt stand, please use the same screws and
tighten them securely.
Do not touch a damaged LCD panel directly with bare hands.
The liquid crystal that may leak from the panel is poisonous if it enters the eyes or mouth. If any
part of the skin or body comes in direct contact with the panel, please wash thoroughly. If some
physical symptoms result, please consult your doctor.
Fluorescent backlight lamps contain mercury (the products that have LED backlight lamps contain
no mercury), dispose according to local, state or federal laws.
Exposure to elemental mercury can result in effects on the nervous system, including tremor, memory loss, and
headache.
PRECAUTIONS
5
CAUTION
Handle with care when carrying the unit.
Disconnect the power cord and cables when moving the unit. Moving the unit with the cord attached is dangerous.
It may result in injury.
Carry or place the unit according to the correct specified methods.
• When carrying the unit, grasp and hold firmly as shown in the illustration below.
• Do not unpack or carry the unit only by a single person, since the large size unit is so heavy.
Dropping the unit may result in injury or equipment damage.
Do not block the ventilation slots on the cabinet.
• Do not place any objects on the ventilation slots.
• Do not install the unit in a closed space.
• Do not use the unit laid down or upside down.
Blocking the ventilation slots prevents proper airflow and may result in fire, electric shock, or
equipment damage.
Do not touch the plug with wet hands.
Doing so may result in electrical shock.
Use an easily accessible power outlet.
This will ensure that you can disconnect the power quickly in case of a problem.
Periodically clean the area around the plug.
Dust, water, or oil on the plug may result in fire.
Unplug the unit before cleaning it.
Cleaning the unit while it is plugged into a power outlet may result in electric shock.
If you plan to leave the unit unused for an extended period, disconnect the power cord from the wall
socket after turning off the power switch for the safety and the power conservation.
This product is only suitable for a patient environment, but not for contact with a patient.
6
PRECAUTIONS
Notice for this monitor
This product has been adjusted specifically for use in the region to which it was originally shipped. If the product is
used outside the region, it may not operate as specified in the specifications.
This product may not be covered by warranty for uses other than those described in this manual.
The specifications noted in this manual are only applicable when the following are used:
· Power cords provided with the product
· Signal cables specified by us
Only use optional products manufactured or specified by us with this product.
It takes about 30 minutes for the performance of electrical parts to stabilize. Please wait 30 minutes or more after
the monitor power has been turned on or the monitor has recovered from the power saving mode, and then adjust the
monitor.
It takes about a few minutes for the image quality to reach acceptable level. Please wait a few minutes or more after the
monitor power has been turned on or the monitor has recovered from the power saving mode, and then view images
for diagnosis.
Monitors should be set to a lower brightness to reduce changes in luminosity caused by long-term use and maintain a
stable display.
When the screen image is changed after displaying the same image for extended periods of time, an afterimage may
appear. Use the screen saver or power save function to avoid displaying the same image for extended periods of time.
Periodic cleaning is recommended to keep the monitor looking new and to prolong its operation lifetime (refer to
“Cleaning” (page 8)).
The screen may have defective pixels or a small number of light dots on the screen. This is due to the characteristics of
the panel itself, and is not a malfunction of the product.
The backlight of the LCD panel has a fixed lifetime. When the screen becomes dark or begins to flicker, please contact
your local EIZO representative.
Do not press on the panel or edge of the frame strongly, as this may result in display malfunctions, such as interference
patterns, etc. If pressure is continually applied to the panel, it may deteriorate or damage your panel. (If the pressure
marks remain on the panel, leave the monitor with a black or white screen. The symptom may disappear.)
Do not scratch or press on the panel with any sharp objects, as this may result in damage to the panel. Do not attempt
to brush with tissues as this may scratch the panel.
When the monitor is cold and brought into a room or the room temperature goes up quickly, dew condensation may
occur on the interior and exterior surfaces of the monitor. In that case, do not turn the monitor on. Instead wait until
the dew condensation disappears, otherwise it may cause some damage to the monitor.
Notice for this monitor
7
English
This product is intended to be used in displaying and viewing digital images including those of digital mammography
for review and analysis by trained medical practitioners.
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.
Cleaning
Attention
• Chemicals such as alcohol and antiseptic solution may cause gloss variation, tarnishing, and fading of the cabinet or panel,
and also quality deterioration of the image.
• Never use any thinner, benzene, wax, and abrasive cleaner, which may damage the cabinet or panel.
Note
• The optional ScreenCleaner is recommended for cleaning the cabinet and panel surface.
The stains on the cabinet and panel surface can be removed by moistening part of a soft cloth with water.
To use the monitor comfortably
• An excessively dark or bright screen may affect your eyes. Adjust the brightness of the monitor according to
the environmental conditions.
• Staring at the monitor for a long time tires your eyes. Take a 10-minute rest every hour.
8
Notice for this monitor
CONTENTS
English
Cover....................................................................... 1
PRECAUTIONS....................................................... 3
●●IMPORTANT.................................................... 3
Notice for this monitor.......................................... 7
Cleaning..................................................................... 8
To use the monitor comfortably.............................. 8
CONTENTS.............................................................. 9
Chapter 1 Introduction...................................... 10
1-1.
Features.........................................................10
1-2.
Package Contents.........................................11
1-3.
EIZO LCD Utility Disk...................................11
●●Disk contents and software overview.............11
●●Using RadiCS LE/ScreenManager Pro
for Medical.......................................................11
1-4.
Controls and Functions...............................12
Chapter 2 Setting Up......................................... 13
2-1.
Compatible Resolutions..............................13
2-2.
Connecting Cables.......................................13
2-3.
Adjusting the Screen Height and Angle.....14
Chapter 3 Troubleshooting............................... 15
●●Error code table..............................................16
Chapter 4 Specifications.................................. 17
Chapter 5 Glossary........................................... 19
Appendix............................................................... 20
Trademark................................................................ 20
License..................................................................... 20
Medical Standard.....................................................21
FCC Declaration of Conformity............................. 22
EMC Information..................................................... 23
China Measures for RoHS Compliance in
ChinaRoHS............................................................... 26
CONTENTS
9
Chapter 1 Introduction
Thank you very much for choosing an EIZO monochrome LCD monitor.
1-1. Features
• 21.3 inches
• Supports a resolution of 5M pixels (Portrait: 2048 × 2560 dots (H × V))
• Uses high-contrast panel (1200:1).
Enables the display of sharp images.
• Applicable to DisplayPort (applicable to 8 bit or 10 bit, not applicable to audio signals)
• The Hybrid Gamma function automatically identifies the display area for the medical and other images on
the same screen, and displays each set status.
*1 The identification may fail depending on the displayed image. The software to be used needs to be verified. For
validation, refer to the Installation Manual (on the CD-ROM).
• The RadiCS SelfQC function and the built-in integrated front sensor allow the user to perform the calibration
and Grayscale Check for the monitor independently.
Refer to the Installation Manual (on the CD-ROM).
*2 When a panel protector (RP-901) is installed, the Integrated Front Sensor cannot be used.
• The CAL Switch function allows the user to select the display mode optimum to the displayed image.
-- The ALT mode adjusts the brightness according to the ambient illuminance.
-- Most suitable mode for calibration
Refer to the Installation Manual (on the CD-ROM).
• Selectable DICOM (page 19) Part 14 complied screen.
• The quality control software “RadiCS LE” used to calibrate the monitor and to manage the history is
included.
See “1-3. EIZO LCD Utility Disk” (page 11).
• The software “ScreenManager Pro for Medical” to adjust the screen using the mouse and keyboard is
included
See “1-3. EIZO LCD Utility Disk” (page 11).
• Frame Synchronous mode supported (24.5 to 25.5 Hz (DVI signal input only), 49 to 51 Hz)
• Power saving function
This product is equipped with power saving function.
-- 0 W power consumption when the main power is off
Equipped with main power switch.
When the monitor is not required, the power supply can be shut off using the main power switch
-- Presence Sensor
The sensor on the front side of the monitor detects the movement of a person. When a person moves away from the
monitor, the monitor shifts to the power saving mode automatically and does not display the images on the screen.
Therefore, the function reduces the power consumption.
Refer to the Installation Manual (on the CD-ROM).
• Long service life LED backlight LCD panel
• Built-in ambient light sensor
The ambient light sensor can measure the ambient illuminance in lux. Depending on the environment, the sensor
sometimes indicates different values from those measured by a stand-alone illuminance meter.
The built-in ambient light sensor is used in the ALT mode or when the measurement is triggered by user operation in the
corresponding menu of the “RadiCS/RadiCS LE” quality control software.
For further details about the measured value and how to execute the measurement, refer to the RadiCS/RadiCS LE
User’s Manual (on the CD-ROM).
• Displays HDCP (High-bandwidth Digital Content Protection) protected contents (DisplayPort only).
10
Chapter 1 Introduction
Attention
1-2. Package Contents
Check that all the following items are included in the packaging box. If any items are missing or damaged, contact
your local EIZO representative.
Note
• Please keep the packaging box and materials for future movement or transport of the monitor.
• USB cable: UU300
• EIZO LCD Utility Disk (CD-ROM)
• Instructions for Use (this manual)
• Monitor
• Power cord
• Digital signal cable: DisplayPort - DisplayPort
(PP300)
• Digital signal cable: DVI-D - DVI-D (Dual Link)
(DD300DL)
1-3. EIZO LCD Utility Disk
An “EIZO LCD Utility Disk” (CD-ROM) is supplied with this product. The following table shows the disk contents
and the overview of the software programs.
●●Disk contents and software overview
The disk includes application software programs for adjustment, and Installation Manual. Refer to Readme.txt
file on the disk for software startup procedures or file access procedures.
Contents
Overview
Readme.txt file
RadiCS LE (for Windows)
Quality control software for calibrating the monitor and managing the
calibration history.
ScreenManager Pro for Medical (for
Windows)
Software for adjusting the screen using the mouse and keyboard.
Installation Manual of this monitor (PDF file)
“Instructions for Use” of this monitor (PDF file)
●●Using RadiCS LE/ScreenManager Pro for Medical
For the installation and use of “RadiCS LE/ScreenManager Pro for Medical”, refer to the respective User’s
Manual on the disk.
When using this software, you will need to connect a PC to the monitor with the supplied USB cable. For more
information, refer to the Installation Manual (on the CD-ROM).
Chapter 1 Introduction
11
English
• A high temperature or high humidity environment may affect the measurement accuracy of the integrated front sensor.
We suggest storing and using the monitor under the following conditions.
-- Temperature 30˚C or less
-- Humidity 70% or less
• Avoid storing or using the sensor where it may be exposed to direct sunlight.
1-4. Controls and Functions
8
7
17
16
Adjustment menu*1
1
2
3
1. Presence Sensor
button
2.
3.
button
button
4.
button
5.
6.
button
7. Ambient Light Sensor
8. Integrated Front Sensor
(slide type)
9. Main power switch
10. Power connector
11. PS/2 connector
4
5
6
9
10
11
18
12
13 1415
Detects the movement of a person in front of the monitor.
Switches the CAL Switch mode.
Cancels the setting/adjustment and exits the Adjustment menu.
Provides the menu selection as well as the adjustment and setting of a function.
Displays the Adjustment menu, determines an item on the menu screen, and saves
values adjusted.
• Turns the power on or off.
• Indicates the monitor’s operation status.
Green: Operating, Orange: Power saving mode, Off: Main power/power off
Measures the environmental illumination.
Used for calibration and Grayscale Check.
Turns the main power on or off.
Connects the power cord.
Used for maintenance. Do not use for other applications. This may cause the monitor
to malfunction.
12. Input signal connector
DVI-D connector
DisplayPort connector
13. Input signal connector
14. USB upstream port
Connects the USB cable to use the software that needs USB connection, or to use
USB Hub function.
15. USB downstream port
Connects a peripheral USB device.
16. Security lock slot
Complies with Kensington’s MicroSaver security system.
17. Stand
Used to adjust the height and angle of the monitor screen.
18. Cable holder
Covers the monitor cables.
*1 For instructions for use, refer to the Installation Manual (on the CD-ROM).
12
Chapter 1 Introduction
Chapter 2 Setting Up
English
2-1. Compatible Resolutions
The monitor supports the following resolutions.
√ : Supported
Resolution
vertical
Applicable
scan
signal
frequency
Dot
Clock
720 × 400
VGA TEXT
70 Hz
640 × 480
VGA
60 Hz
800 × 600
VESA
60 Hz
1024 × 768
VESA
60 Hz
1280 × 1024
VESA
60 Hz
290 MHz
1600 × 1200
VESA
60 Hz
(Max.)
2560 × 2048
VESA CVT
50 Hz
2048 × 2560
VESA CVT
50 Hz
2560 × 2048
VESA CVT
25 Hz
2048 × 2560
VESA CVT
25 Hz
2048 × 2560
SDG
25 Hz
*1
A supported graphics board is required to display.
*2
Dual Link
DVI
DisplayPort
SDG*1
Portrait Landscape Portrait Landscape Portrait
√
√
√
√
√
√
√*2
√
-
√
√
√
√
√
√
√*2
√
-
√
√
√
√
√
√
√
-
√
√
√
√
√
√
√
-
√
√
√
√
√
√
√
2-2. Connecting Cables
Attention
• Check that the monitor and the PC are powered off.
• When replacing the current monitor with this monitor, be sure to change the PC settings for resolution and vertical scan
frequency to those that are available for this monitor. Refer to the compatible resolution table before connecting the PC.
Note
• When connecting multiple PCs to this product, refer to the Installation Manual (on the CD-ROM).
1.Turn the monitor screen 90˚ in clockwise direction.
The landscape position is the default monitor orientation. Turn the monitor screen ninety degrees to portrait
position before installing it.
2.Connect the signal cables to the input signal connectors and PC.
Check the shape of the connectors, and connect the cables.
After connecting the signal cable, tighten the screws of the connectors to secure the coupling.
Chapter 2 Setting Up
13
Digital connection
(DisplayPort)
Digital connection
(DVI)
Signal cable: DisplayPort - DisplayPort
(supplied)
or
Signal cable: DVI-D - DVI-D (Dual Link)
(supplied)
3.Plug the power cord into a power outlet and the power connector on the
monitor.
4.Connect the USB cable when using RadiCS LE or ScreenManager Pro for
Medical.
Connecting to the Monitor
5.Press
Connecting to a Computer
to turn on the monitor.
The monitor’s power indicator lights up green.
6.Turn on the PC.
The screen image appears.
If an image does not appear, refer to “Chapter 3 Troubleshooting” (page 15) for additional advice.
Attention
• Turn off the monitor and PC after using them.
• For the maximum power saving, it is recommended that the Power button be turned off. Turning off the main power switch
or unplugging the power cord completely shuts off power supply to the monitor.
2-3. Adjusting the Screen Height and Angle
Hold left and right edge of the monitor with both hands, and adjust the screen height, tilt and swivel of the screen to
the best condition for working.
Attention
• Be sure that the cables are correctly connected.
14
Chapter 2 Setting Up
Chapter 3 Troubleshooting
Problem
1. No picture
• Power indicator does not light.
• Power indicator is lighting orange and green.
• Power indicator is flashing orange and green.
2. The message below appears.
Possible cause and remedy
•
•
•
•
Check whether the power cord is connected properly.
Turn the main power switch on.
Press .
Turn off the main power, and then turn it on again a few
minutes later.
• Switch the input signal. For details, refer to the Installation
Manual (on the CD-ROM).
• Move the mouse or press any key on the keyboard.
• Check whether the PC is turned on.
• When Presence Sensor is set to “Auto” or “Manual”, the
monitor may have shifted to the power saving mode.
Come near to the monitor.
• The device that is connected using DisplayPort have a
problem. Solve the problem, turn off the monitor, and then
turn it on again. Refer to the User’s Manual of the output
device for further details.
This message appears when the signal is not input correctly
even when the monitor functions properly.
• This message appears when no signal is
input.
Example:
• The message shown left may appear, because some PCs
do not output the signal soon after power-on.
• Check whether the PC is turned on.
• Check whether the signal cable is connected properly.
• Switch the input signal. For details, refer to the Installation
Manual (on the CD-ROM).
• The message shows that the input signal is
out of the specified frequency range. 
Example:
• Check whether the PC is configured to meet the resolution
and vertical scan frequency requirements of the monitor
(see “2-1. Compatible Resolutions” (page 13).).
• Reboot the PC.
• Select an appropriate setting using the graphics board’s
utility. Refer to the manual of the graphics board for
details.
fD: Dot clock
fH: Horizontal scan frequency
fV: Vertical scan frequency
Chapter 3 Troubleshooting
15
English
If a problem still remains after applying the suggested remedies, contact your local EIZO representative.
●●Error code table
Error Code
16
Description
0***
• Errors that occurred during SelfCalibration
1***
• Errors that occurred during Grayscale Check
*1**
• Errors that occurred during DICOM
*2**
• Errors that occurred during CAL1
*3**
• Errors that occurred during CAL2
**10
• The product maximum brightness may be lower than the target brightness.
• Lower the target brightness.
**11
• The product minimum brightness may be higher than the target brightness.
• Raise the target brightness.
**34
• The sensor may not have come out during calibration, or light may have entered the
sensor.
• Turn off the main power, wait for a few minutes before turning the power back on, and
then execute SelfCalibration/Grayscale Check again.
**61
• The sensor may not have come out.
• Check whether there is any foreign object near the sensor.
• Execute SelfCalibration/Grayscale Check again.
**95
• The execution conditions for SelfCalibration/Grayscale Check may not be appropriate.
• Check the execution conditions and reset them if necessary.
Chapter 3 Troubleshooting
Chapter 4 Specifications
Size
21.3-inch (540 mm)
Type
TFT monochrome LCD, LED backlight
Surface treatment
Anti-glare
Surface hardness
2H
Viewing angles
Horizontal 176˚, vertical 176˚ (CR≥10)
Dot pitch
0.165 mm
Response time
Black-white-black: Approx. 25 ms
English
LCD Panel
Horizontal scan frequency
31-135kHz
Vertical scan frequency
DVI:
24 - 61 Hz (non-interlace)
(VGA TEXT: 69 to 71 Hz, QSXGA (2048 × 2560): 24
to 51 Hz)
DisplayPort:
49 - 61 Hz (non-interlace)
(VGA TEXT: 69 to 71 Hz, QSXGA (2048 × 2560): 49
to 51 Hz)
Resolution
5M pixels (Portrait orientation: 2048 dots × 2560 lines (H × V))
Max. dot clock
290MHz
Display grayscales
1,024 steps of 16,369 steps
Recommended Brightness
500 cd/m2
Display area (H × V)
337.9 mm (13.30 inch) × 422.4 mm (16.63 inch) (Portrait orientation)
Power supply
100 - 120 Vac ±10%, 50/60 Hz 1.1 - 0.9A
200 - 240 Vac ±10%, 50/60 Hz 0.6 - 0.5A
Power
consumption
Screen display On
108 W or less
Power saving mode
0.7 W or less
(when only the DVI signal connector is connected,
no USB device is connected, “Input Selection” is set
to “Manual”, “DC5V Output” is set to “Off”, and “DP
Power Save” is set to “On”)
Power Off
0.5 W or less
(when no USB device is connected, “DC5V Output”
is set to “Off”, and “DP Power Save” is set to “On”)
Main power Off
0W
Input signal connectors
DVI-D connector
DisplayPort connector (Standard V1.1a, applicable to HDCP)
Digital Signal (DVI) Transmission System TMDS (Single Link / Dual Link)
Plug & Play
Dimensions
(width) × (height)
× (depth)
Mass
Movable range
Environmental
conditions
Digital (DVI-D): VESA DDC 2B / EDID structure 1.3
Digital (DisplayPort) : VESA DisplayPort / EDID structure 1.4
Main unit
388 mm (15.3 inch) × 512 - 595 mm (20.2 - 23.4 inch) × 245.5 mm (9.7
inch)
Main unit (without
stand)
388 mm (15.3 inch) × 496 mm (19.5 inch) × 99 mm (3.9 inch)
Main unit
Approx. 11.5 kg (25.4 lbs.)
Main unit (without
stand)
Approx. 8.8 kg (19.4 lbs.)
FlexStand
Tilt:
Up 30˚, down 0˚
Swivel:
344˚
Adjustable height:
174 mm (Tilt: 30˚), 83 mm (Tilt: 0˚)
Rotation:
90˚ (counterclockwise for portrait display)
Operating:
0˚C to 35˚C (32˚F to 95˚F)
Temperature
Humidity
Air pressure
Transportation/Storage:
-20˚C to 60˚C (-4˚F to 140˚F)
Operating:
20% to 80% R.H. (no condensation)
Transportation/Storage:
10% to 90% R.H. (no condensation)
Operating:
700 hPa to 1060 hPa
Transportation/Storage:
200 hPa to 1060 hPa
Chapter 4 Specifications
17
USB
Standard
USB Specification Revision 2.0
Port
Upstream port × 1, Downstream port × 2
Communication
Speed
480 Mbps (high), 12 Mbps (full)
1.5 Mbps (low)
Supply current
Downstream: Max. 500 mA/1 port
Outside Dimensions
Unit: mm (inch)
30°
TILT
146.5 (5.8)
236 (9.3)
512 (20.2)
455 (17.9)
65.5 (2.58)
99 (3.90)
94.5 (3.72) 171 (6.7)
344°
SWIVEL
105 (4.1) 3 (0.12)
350 (13.8)
LOWEST POSITION
144 (5.7) 100 (3.9) 144 (5.7)
18 (0.71)
206 (8.1)
320 (12.6)
360.5 (14.2)
629 (24.8)
100 (3.9)
190 (7.5)
28 (1.10)
44 (1.73)
99 (3.90)
549 (21.6)
161 (6.3)
211 (8.3)
355 (14.0)
173 (6.8)
15 (0.59)
°
90
PIVOT
320 (12.6)
30° TIL
T
24 (0.94)
424 (16.7)
496 (19.5)
595 (23.4)
24 (0.94)
388 (15.3)
340 (13.4)
209.5 (8.2)
245.5 (9.7)
HIGHEST POSITION
Accessories
Calibration Kit
Network QC Management Software
Cleaning Kit
EIZO “RadiCS UX1” Ver. 4.1.4 or later
EIZO “RadiCS Version Up Kit” Ver. 4.1.4 or later
EIZO “RadiNET Pro” Ver. 4.1.4 or later
EIZO “ScreenCleaner”
For the latest information about the accessories and information about the latest compatible graphics board, refer to our
web site.
http://www.eizo.com
18
Chapter 4 Specifications
Chapter 5 Glossary
English
DDC (Display Data Channel)
VESA provides the standardization for the interactive communication of the setting information, etc.
between a PC and the monitor.
DICOM (Digital Imaging and Communication in Medicine)
The DICOM standard was developed by the American College of Radiology and the National Electrical
Manufacturer’s Association of the USA.
The DICOM compatible device connection enables to transfer the medical image and information. The
DICOM, Part 14 document defines the digital, grayscale medical image display.
DisplayPort
DisplayPort is a next-generation digital AV interface that allows connection of the PC, audio, imaging
devices, etc. to the monitor. One cable can transfer sound with images.
DVI (Digital Visual Interface)
DVI is a digital interface standard. DVI allows direct transmission of the PC’s digital data without loss.
This adopts the TMDS transmission system and DVI connectors. There are two types of DVI connectors.
One is a DVI-D connector for digital signal input only. The other is a DVI-I connector for both digital and
analog signal inputs.
DVI DMPM (DVI Digital Monitor Power Management)
DVI DMPM is a digital interface power saving function. The “Monitor ON (operating mode)” and “Active
Off (power saving mode)” are indispensable for DVI DMPM as the monitor’s power mode.
HDCP (High-bandwidth Digital Content Protection)
Digital signal coding system developed to copy-protect the digital contents, such as video, music, etc.
This helps to transmit the digital contents safely by coding the digital contents sent via the DVI or HDMI
connector on the output side and decoding them on the input side.
Any digital contents cannot be reproduced if both of the equipments on the output and input sides are not
applicable to HDCP system.
Resolution
The LCD panel consists of numerous pixels of specified size, which are illuminated to form images. This
monitor consists of horizontal 2048 pixels and 2560 vertical pixels. At a resolution of 2048 × 2560 (Portrait)
and 2560 × 2048 (landscape), all pixels are illuminated as a full screen (1:1).
TMDS (Transition Minimized Differential Signaling)
A signal transmission system for digital interface.
Chapter 5 Glossary
19
Appendix
Trademark
The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or
registered trademarks of HDMI Licensing, LLC in the United States and other countries.
The DisplayPort Compliance Logo and VESA are registered trademarks of the Video Electronics Standards
Association.
Acrobat, Adobe, Adobe AIR, and Photoshop are registered trademarks of Adobe Systems Incorporated in the
United States and other countries.
AMD Athlon and AMD Opteron are trademarks of Advanced Micro Devices, Inc.
Apple, ColorSync, eMac, iBook, iMac, iPad, Mac, MacBook, Macintosh, Mac OS, PowerBook, and QuickTime
are registered trademarks of Apple Inc.
ColorMunki, Eye-One, and X-Rite are registered trademarks or trademarks of X-Rite Incorporated in the United
States and/or other countries.
ColorVision and ColorVision Spyder2 are registered trademarks of DataColor Holding AG in the United States.
Spyder3 and Spyder4 are trademarks of DataColor Holding AG.
ENERGY STAR is a registered trademark of the United States Environmental Protection Agency in the United
States and other countries.
GRACoL and IDEAlliance are registered trademarks of International Digital Enterprise Alliance.
NEC is a registered trademark of NEC Corporation.
PC-9801 and PC-9821 are trademarks of NEC Corporation.
NextWindow is a registered trademark of NextWindow Ltd.
Intel, Intel Core and Pentium are registered trademarks of Intel Corporation in the United States and other
countries.
PowerPC is a registered trademark of International Business Machines Corporation.
PlayStation is a registered trademark of Sony Computer Entertainment Inc.
PSP and PS3 are trademarks of Sony Computer Entertainment Inc.
RealPlayer is a registered trademark of RealNetworks, Inc.
TouchWare is a trademark of 3M Touch Systems, Inc.
Windows, Windows Media, Windows Vista, SQL Server, and Xbox 360 are registered trademarks of Microsoft
Corporation in the United States and other countries.
YouTube is a registered trademark of Google Inc.
Firefox is a registered trademark of the Mozilla Foundation.
Kensington and MicroSaver are trademarks of ACCO Brands Corporation.
EIZO, the EIZO Logo, ColorEdge, DuraVision, FlexScan, FORIS, RadiCS, RadiForce, RadiNET, Raptor, and
ScreenManager are registered trademarks of EIZO Corporation in Japan and other countries.
ColorNavigator, EcoView NET, EIZO EasyPIX, EIZO ScreenSlicer, i • Sound, Screen Administrator, and UniColor
Pro are trademarks of EIZO Corporation.
All other company and product names are trademarks or registered trademarks of their respective owners.
License
A round gothic bold bit map font designed by Ricoh is used for the characters displayed on this product.
20
Appendix
Medical Standard
English
• It shall be assured that the final system is in compliance to IEC60601-1-1 requirement.
• Power supplied equipment can emit electromagnetic waves, that could influence, limit or result in
malfunction of the monitor. Install the equipment in a controlled environment, where such effects are
avoided.
Classification of Equipment
------
Type of protection against electric shock : Class I
EMC class: EN60601-1-2:2007 Group 1 Class B
Classification of medical device (MDD 93/42/EEC) : Class I
Mode of operation : Continuous
IP Class : IPX0
Appendix
21
FCC Declaration of Conformity
For U.S.A. , Canada, etc. (rated 100-120 Vac) Only
FCC Declaration of Conformity
We, the Responsible Party
EIZO Inc.
5710 Warland Drive, Cypress, CA 90630
Phone: (562) 431-5011
declare that the product
Trade name: EIZO
Model: RadiForce GX540
is in conformity with Part 15 of the FCC Rules. Operation of this product is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures.
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
* Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Note
Use the attached specified cable below or EIZO signal cable with this monitor so as to keep interference
within the limits of a Class B digital device.
- AC Cord
- Shielded Signal Cable (enclosed)
Canadian Notice
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de le classe B est comforme à la norme NMB-003 du Canada.
22
Appendix
EMC Information
Essential performance of RadiForce series is to display images and operate functions normally.
The RadiForce series requires special precautions regarding EMC and need to be installed, put into
service and used according to the following information.
Do not use any cables other than the cables that provided or specified by us.
Using other cables may cause the increase of emission or decrease of immunity.
Cable Length: Max. 3m
Do not put any portable and mobile RF communications equipment close to the RadiForce series.
Doing so may affect the RadiForce series.
The RadiForce series should not be used adjacent to or stacked with other equipment. If adjacent
or stacked use is necessary, the equipment or system should be observed to verify normal
operation in the configuration in which it will be used.
Anyone who connects additional equipment to the signal input part or signal output parts,
configuring a medical system, is responsible that the system complies with the requirements of
IEC/EN60601-1-2.
Guidance and manufacturer’s declaration - electromagnetic emissions
The RadiForce series is intended for use in the electromagnetic environment specified below. 
The customer or the user of the RadiForce series should assure that it is used in such an environment.
Emission test
RF emissions
CISPR11/EN55011
Compliance
Group 1
RF emissions
Class B
CISPR11/EN55011
Harmonic emissions Class D
IEC/EN61000-3-2
Voltage fluctuations / Complies
flicker emissions
IEC/EN61000-3-3
Electromagnetic environment - guidance
The RadiForce series uses RF energy only for its internal function.
Therefore, its RF emission are very low and are not likely to cause any
interference in nearby electronic equipment.
The RadiForce series is suitable for use in all establishments, including domestic
establishments and those directly connected to the public low-voltage power
supply network that supplies buildings used for domestic purposes.
Guidance and manufacturer’s declaration - electromagnetic immunity
The RadiForce series is intended for use in the electromagnetic environment specified below. 
The customer or the user of the RadiForce series should assure that it is used in such an environment.
Immunity test
Electrostatic 
discharge (ESD)
IEC/EN61000-4-2
Electrical fast
transient / burst
IEC/EN61000-4-4
Surge
IEC/EN61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines 
IEC/EN61000-4-11
IEC/EN60601 test
level
±6kV contact
±8kV air
Compliance level Electromagnetic environment - guidance
±6kV contact
±8kV air
±2kV 
for power supply lines
±1kV 
for input/output lines
±1kV line(s) to line(s)
±2kV line(s) to earth
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the
relative humidity should be at least 30%.
Mains power quality should be that of a typical
±2kV 
for power supply lines commercial or hospital environment.
±1kV 
for input/output lines
±1kV line(s) to line(s) Mains power quality should be that of a typical
±2kV line(s) to earth commercial or hospital environment.
<5% UT (>95% dip in
UT) for 0.5 cycle
40% UT (60% dip in UT)
for 5 cycles
70% UT (30% dip in UT)
for 25 cycles
<5% UT (>95% dip in
UT) for 5sec
3A/m
<5% UT (>95% dip in
UT) for 0.5 cycle
40% UT (60% dip in
UT) for 5 cycles
70% UT (30% dip in
UT) for 25 cycles
<5% UT (>95% dip in
UT) for 5sec
3A/m
Mains power quality should be that of a typical
commercial or hospital environment. If the user
of the RadiForce series requires continued
operation during power mains interruptions, it
is recommended that the RadiForce series be
powered from an uninterruptible power supply or
a battery.
Power frequency magnetic fields should be at
Power frequency
levels characteristic of a typical location in a
(50/60Hz)
typical commercial or hospital environment.
magnetic field
IEC/EN61000-4-8
NOTE UT is the a.c. mains voltage prior to application of the test level.
Appendix
23
English
CAUTION
Guidance and manufacturer’s declaration - electromagnetic immunity
The RadiForce series is intended for use in the electromagnetic environment specified below. The customer or the user
of the RadiForce series should assure that it is used in such an environment.
Immunity test
IEC/EN60601 test
level
Compliance level
Conducted RF
IEC/EN61000-4-6
3Vrms
150kHz to 80MHz
3Vrms
Radiated RF
IEC/EN61000-4-3
3V/m
80MHz to 2.5GHz
3V/m
Electromagnetic environment - guidance
Portable and mobile RF communications
equipment should be used no closer to any part
of the RadiForce series, including cables, than the recommended separation distance calculated
from the equation applicable to the frequency of
the transmitter.
Recommended Separation distance
d = 1.2 √P

d = 1.2 √P, 80MHz to 800MHz
d = 2.3 √P, 800MHz to 2.5GHz
Where “P” is the maximum output power rating
of the transmitter in watts (W) according to
the transmitter manufacturer and “d” is the
recommended separation distance in meters (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site surveya,
should be less than the compliance level in each
frequency rangeb.
Interference may occur in the vicinity of equipment
marked with the following symbol.
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which the RadiForce series is used exceeds
the applicable RF compliance level above, the RadiForce series should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the
RadiForce series.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
24
Appendix
Recommended separation distances between portable and mobile RF communications equipment
and the RadiForce Series
NOTE 1
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
Appendix
25
English
The RadiForce series is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the RadiForce series can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the
RadiForce series as recommended below, according to the maximum output power of the communications equipment.
Separation distance according to frequency of transmitter
Rated maximum output
m
power of transmitter
80MHz to 800MHz
150kHz to 80MHz
800MHz to 2.5GHz

d = 1.2 √P
d = 1.2 √P
d = 2.3 √P
W
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance “d” in
meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where “P” is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
China Measures for RoHS Compliance in ChinaRoHS
About the Electronic Information Products Pollution Control Symbol
This symbol identifies products regulated by the ‘Measures for the Administration of the Control of Pollution by
Electronic Information Products,’ and is applicable to electronic information products for sale in the People’s Republic
of China.The number in the circle is the Environmentally Friendly Use Period (EFUP).Compliance with the relevant
safety precautions ensures that the product will not cause environmental pollution, bodily harm, or property damage
within the specified period of time since the date of manufacture. The label is attached to the back of the device.
• Name and Concentration of Hazardous Substances
Component Name
Hazardous Substance Name
Cadmium
Hexavalent Polybrominated Polybrominated
Biphenyls
Diphenyl Ethers
(Cd)
Chromium
(PBB)
(PBDE)
(Cr(VI))
Printed Circuit Boards
×
○
○
○
○
○
Casing
○
○
○
○
○
○
LCD Monitors
×
○
○
○
○
○
Other
×
○
○
○
○
○
○ : Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is
below the limit requirement in SJ/T11363-2006.
× : Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for
this part is above the limit requirement in SJ/T11363-2006.
(Companies can use this space to provide further explanation of the technical situation behind the ‘×’ in the table
above.)
26
Appendix
Lead
(Pb)
Mercury
(Hg)
153 Shimokashiwano, Hakusan, Ishikawa 924-8566 Japan
Phone: +81 76 277 6792 Fax: +81 76 277 6793
中国苏州市苏州工业园区展业路8号中新科技工业坊5B
Phone: +86 512 6252 0100 Fax: +86 512 6252 1508
Siemensallee 84, 76187 Karlsruhe, Germany
Phone: +49 721 20321 0 Fax: +49 721 20321 471
http://www.eizo.com
Copyright © 2013 EIZO Corporation All rights reserved.
1st Edition-October, 2013
Printed in Japan.
00N0L834A1
(U.M-GX540-4)