HP 1/10Gb Virtual Connect Ethernet Module for c

QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Overview
Simplify and make your data center change-ready. The HP 1/10Gb Virtual Connect Ethernet Module for the c-Class BladeSystem is
the simplest, most flexible connection to your networks. The Virtual Connect Ethernet Module is a new class of blade interconnect that
simplifies server connections by cleanly separating the server enclosure from LAN, simplifies networks by reducing cables without
adding switches to manage, and allows you to change servers in just minutes, not days. The HP 1/10Gb Virtual Connect Module for
c-Class BladeSystem is an innovative, new class of integrated interconnects from HP.
Figure 1 Virtual Connect Ethernet Module Front Bezel
1. X1 10GBASE-CX4 port
4. Ports 1-8 (10/100/1000BASE-T)
2. X2 10GBASE-CX4 port
5. Reset button (recessed)
3. USB 2.0 connector (covered, for future use)
6. Next button
What's New
Support for HP BladeSystem c3000 Enclosure
Stacking with the HP 1/10Gb-F Virtual Connect Ethernet Module
Enhanced with new enterprise level LAN management tools, Virtual Connect can be administered via SNMP and a scriptable
Command Line Interface. LAN traffic can be also be monitored with common network analysis tools assuring maximum
uptime and performance.
Models
HP 1/10Gb Virtual Connect Ethernet Module for c-Class BladeSystem
399593-B22
At A Glance
Performance
(2) 10GBASE-CX4 uplinks can be connected to core switches or used to stack Virtual Connect modules
(8) 10/100/1000BASE-T uplinks can be connected to core switches or used to stack Virtual Connect modules
Wire speed performance on all ports
IGMP Snooping optimizes network traffic and reduces bandwidth for multicast applications such as streaming applications
VLAN Tagging, Pass-Thru and Link Aggregation supported on all uplinks
Management
Virtual Connect Manager is included with every module
HTTP and a secure, scriptable CLI interface is ready out of the box. Easy setup and management via the Onboard
Administrator interface
SNMP v.1 and v.2, provide ease of administration and maintenance.
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 1
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Overview
Role-based security for network and server administration with LDAP compatibility
Port Mirroring on any uplink provides network troubleshooting support with Network Analyzers
Appears as a Pass-Thru device to the LAN Manager
Virtual Connect Server Profiles
Allows setup of server connectivity prior to server installation for easy deployment
Ability to move, add, or change server network connections on the fly
Once defined, LAN and SAN administrators don't have to be involved in server changes
Options
Stack multiple Virtual Connect Ethernet modules together in an enclosure to allow any server Ethernet port to connect to any
uplink
The Fibre Channel Virtual Connect Module provides a complete LAN and SAN Virtual Connect solution
HP CX-4 Ethernet cables are available in .5m, 1m, 3m, and 15m lengths
Supports all Server NIC's including LOM and Mezzanine card options
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 2
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
QuickSpecs
Supported Products
Compatibility
HP ProLiant Servers
All HP ProLiant BladeSystem c-Class Server Blades with latest ROM updates
Supports all Server NIC's including LOM and Mezzanine card options
Virtual Connect requires the following minimum firmware levels:
BL460c BIOS - System ROM version 2007.05.01 or later
BL480c BIOS-System ROM version 2007.05.01 or later
BL465c BIOS - System ROM version 2007.04.05 or later
BL685c BIOS - System ROM version 2007.04.05 or later
Server Mezzanine Cards:
QLogic QMH2462 4Gb FC HBA QLogic Firmware loaded when driver is loaded. Use QLogic
BIOS version 1.26 (in Multiboot 1.63) or later
HP Emulex LPe 1105-HP 4Gb FC BIOS version 6.00a2 (3.00a4) or later
ProLiant BL c-Class
Server Blade Enclosures
For the latest additional information on required firmware versions and to download firmware upgrades,
see the HP website http://www.hp.com/go/bladesystemupdates.
The HP BladeSystem c3000 and c7000 Enclosures have been designed up front with the Virtual Connect
Architecture in mind incorporating the HP Onboard Administrator, ILO Management, and HP
Management tools inside the Virtual Connect framework.
Virtual Connect requires the following minimum firmware levels:
Single and redundant Onboard Administrators - (version 2.01 or later)
Supported Configurations
1. Upper Fan System
2. Interconnect Bays 1 /2
3. Interconnect Bays 3 / 4
HP BladeSystem c7000 Enclosure - Rear View
5. Interconnect Bays 7 / 8
6. On Board Administrator
7. Lower Fan System
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 3
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Supported Products
4. Interconnect Bays 5 / 6
8. Rear Redundant Power Complex
HP BladeSystem c3000 Enclosure - Front View
1. Device Bays 1 thru 8
4. Insight Display
2. Enclosure DVD Drive
5. Active Onboard Administrator
3. Standby Onboard Administrator (reserved for Future)
1.
2.
3.
4.
5.
6.
HP BladeSystem c3000 Enclosure - Rear View
Local KVM interface (reserved for future)
7. iLO/Onboard Administrator Port
Interconnect Bay 1
8. iLO/Onboard Administrator Port 2 (reserved for future)
Active Cool Fans
9. Power Supplies
Interconnect Bay 2
10. Interconnect Bay 4
Enclosure Up-link and Service Port
11. Interconnect Bay 3
Enclosure Down-link
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 4
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Supported Products
Mezzanines
Port Mapping
Port mapping differs slightly between full height and half height server blades due to the support for
additional Mezzanine cards on the full height version.
HP has simplified the processes of mapping Mezzanine ports to switch ports by providing intelligent
management tools via the Onboard Administrator and HP Insight Manager Software. The Onboard
Administrator Guide, Enclosure Setup and Installation Guide provides detailed information on port
mapping.
c7000 Half Height Server Blade
c7000 Full Height Sever Blade
c3000 Half Height Server Blade
c3000 Full Height Sever Blade
The following are supported configurations for the 1/10Gb Virtual Connect Ethernet Module. Please note that other interconnect
options can be installed in the enclosure, but they do not inherit the benefits of Virtual Connect. Switches and Pass-Thru modules will
operate per their default configurations. Any moves, adds, or changes to servers which are connected to non-Virtual Connect modules
will require reconfiguration on the LAN and/or SAN. The Virtual Connect Manager will only manage Virtual Connect Modules.
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 5
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Supported Products
HP BladeSystem c7000 Enclosure
NOTE: The following tables show a number of typical, supported configurations for an HP BladeSystem c7000 Enclosure.
[Bay 1] VC-Enet
[Bay 3] Other/empty
[Bay 5] Other/empty
[Bay 7] Other/empty
[Bay 2] Empty
[Bay 4] Other/empty
[Bay 6] Other/empty
[Bay 8] Other/empty
[Bay 1] VC-Enet
[Bay 3] Other/empty
[Bay 5] Other/empty
[Bay 7] Other/empty
[Bay 2] VC-Enet
[Bay 4] Other/empty
[Bay 6] Other/empty
[Bay 8] Other/empty
[Bay 1] VC-Enet
[Bay 3] VC-Enet
[Bay 5] Other/empty
[Bay 7] Other/empty
[Bay 2] VC-Enet
[Bay 4] VC-Enet
[Bay 6] Other/empty
[Bay 8] Other/empty
[Bay 1] VC-Enet
[Bay 3] Other/empty
[Bay 5] VC-Enet
[Bay 7] Empty
[Bay 2] VC-Enet
[Bay 4] Other/empty
[Bay 6] VC-Enet
[Bay 8] Empty
[Bay 1] VC-Enet
[Bay 3] VC-Enet
[Bay 5] VC-Enet
[Bay 7] Empty
[Bay 2] VC-Enet
[Bay 4] VC-Enet
[Bay 6] VC-Enet
[Bay 8] Empty
[Bay 1] VC-Enet
[Bay 3] VC-FC
[Bay 5] Other/empty
[Bay 7] Other/empty
[Bay 2] Empty
[Bay 4] Empty
[Bay 6] Other/empty
[Bay 8] Other/empty
[Bay 1] VC-Enet
[Bay 3] VC-FC
[Bay 5] Other/empty
[Bay 7] Other/empty
[Bay 2] VC-Enet
[Bay 4] VC-FC
[Bay 6] Other/empty
[Bay 8] Other/empty
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 6
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Supported Products
[Bay 1] VC-Enet
[Bay 3] VC-Enet
[Bay 5] VC-FC
[Bay 7] Empty
[Bay 2] VC-Enet
[Bay 4] VC-Enet
[Bay 6] VC-FC
[Bay 8] Empty
[Bay 1] VC-Enet*
[Bay 3] VC-Enet
[Bay 5] VC-FC
[Bay 7] VC-FC
[Bay 2] VC-Enet
[Bay 4] VC-Enet
[Bay 6] VC-FC
[Bay 8] VC-FC
* This configuration is only applicable for enclosures with full-height servers.
[Bay 1] VC-Enet
[Bay 3] VC-FC
[Bay 5] VC-Enet
[Bay 7] Empty
[Bay 2] VC-Enet
[Bay 4] VC-FC
[Bay 6] VC-Enet
[Bay 8] Empty
[Bay 1] VC-Enet
[Bay 3] VC-FC
[Bay 5] VC-Enet
[Bay 7] VC-Enet
[Bay 2] VC-Enet
[Bay 4] VC-FC
[Bay 6] VC-Enet
[Bay 8] VC-Enet
[Bay 1] VC-Enet
[Bay 3] Other/empty
[Bay 5] VC-FC
[Bay 7] Empty
[Bay 2] VC-Enet
[Bay 4] Other/empty
[Bay 6] VC-FC
[Bay 8] Empty
[Bay 1] VC-Enet
[Bay 3] VC-FC
[Bay 5] VC-FC
[Bay 7] Empty
[Bay 2] VC-Enet
[Bay 4] VC-FC
[Bay 6] VC-FC
[Bay 8] Empty
[Bay 1] VC-Enet
[Bay 3] VC-Enet
[Bay 5] VC-Enet
[Bay 7] VC-Enet
[Bay 2] VC-Enet
[Bay 4] VC-Enet
[Bay 6] VC-Enet
[Bay 8] VC-Enet
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 7
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Supported Products
HP BladeSystem c3000 Enclosure
NOTE: The following tables show a number of typical, supported configurations for an HP BladeSystem c3000 Enclosure.
[Bay 1] VC-Enet
[Bay 3] Empty
[Bay 2] VC-Enet
[Bay 4] Empty
[Bay 1] VC-Enet
[Bay 3] VC-Enet
[Bay 2] VC-Enet
[Bay 4] VC-Enet
[Bay 1] VC-Enet
[Bay 3] VC-FC
[Bay 2] VC-Enet
[Bay 4] VC-FC
Required Network
Cabling
10BASE-T
Categories 3 UTP or better (up to 100 meters)
EIA/TIA-568 100-ohm STP (up to 100 meters)
100BASE-TX
Category 5 UTP or better (up to 100 meters)
EIA/TIA-568 100-ohm STP (up to100 meters)
1000BASE-T
Category 5e UTP or better (up to 100 meters)
EIA/TIA-568 100-ohm STP (up to 100 meters)
10GBASE-CX4
Twinax CX4 (0.5 to 15m)
NOTE: For available cables; please see the "Options" section below of this QuickSpecs.
Stacking Configuration
Stacking links are used to interconnect Virtual Connect Ethernet Modules when using more than one
enclosure (future) or when using more than two Virtual Connect Ethernet Modules in a single enclosure.
All Virtual Connect Modules within the VC Domain must be interconnected. Any combination of 1Gb
and 10Gb cables can be used to interconnect the Virtual Connect Modules; however the following
provides recommended configurations (note that a built-in 10Gb link is provided between modules in
horizontally adjacent bays). Supported cable lengths on 10Gb uplinks are 3 to 15 meters and supported
10Gb stacking links (connecting between two HP Virtual Connect Ethernet Modules) are 0.5 to 7 meters.
Interconnecting the modules allows all Ethernet NICs on all server blades in the Virtual Connect domain
to have access to any Virtual Connect uplink port. By using these module-to-module links, a single pair
of uplinks can be used as the data center network connections for the entire Virtual Connect domain,
and allows any server blade to be connected to any Ethernet network.
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 8
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Supported Products
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 9
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Service and Support, HP Care Pack and Warranty Information
Service and Support
This product is covered by a global limited warranty and supported by HP Services and a worldwide
network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for
three years from date of purchase. Support for software and initial setup is available for 90 days from
date of purchase. Additional support may be covered under the warranty or available for an additional
fee. Enhancements to warranty services are available through HP Care Pack services or customized
service agreements.
NOTE: Server Blade Interconnect Limited Warranty includes 1 year Parts, 1 year Labor, 1-year on-site
support. Additional information regarding worldwide limited warranty and technical support is available
at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP services provide total care and support expertise with committed response designed to meet your IT
and business needs.
To fully capitalize on your HP BladeSystem servers' capabilities requires a service partner who thoroughly
understands your server technology and systems environment. HP Services, an industry leader in
provision of multi vender support solutions provides a range of support services designed to meet the
varying needs of business. Whether an SMB or large global corporation HP has a HP BadeSystem server
support offer to help you speedily deploy and maximize system uptime.
Recommended Service - simplify ProLiant solution implementation, maintenance, and management.
Support - 3-Year, 24x7, Same Business Day, 4-Hour response coverage
Deployment Service - Installation and Start Up for HP BladeSystem Infrastructure
Enhanced Service - optimize service level to increase IT performance and availability.
Support -1-Year HP Proactive BladeSystem Service
Deployment Service - Enhanced Network Installation and Start-up for HP BladeSystem Switches
Installation & Start-Up service for HP BladeSystem Infrastructure plus HP BladeSystem Enhanced Network
Installation and Start-UP as per the Customer Description and/or Data Sheet. To be delivered on a
scheduled basis 8am-5pm, M-F, excluding HP holidays
For a complete listing of service offerings and information visit:
http://www.hp.com/services/bladesystemservices
http://www.hp.com/go/proliant/carepack
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 10
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
QuickSpecs
Related Options
Cabling Options
HP .5m 10GbE CX4 Cable
HP 1m 10GbE CX4 Cable
HP 3m 10GbE CX4 Cable
HP 15m 10GbE CX4 Cable
Service and Support
Offerings
NOTE: The HP Care Pack service part numbers below for ProLiant BL c-Class server
blades, cover the server blade and all HP branded hardware options qualified for the
server, purchased at the same time or afterwards, internal to the server.
Hardware Services On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
NOTE: HP Care Pack services for the c7000 and c3000 Enclosure cover the
enclosure, power supplies and fans. HP qualified rack options are covered by these
services when installed within the same rack. HP supported c-Class enclosure devices
including pass thru, Ethernet interconnect and virtual connect modules are also
covered by the c7000 and c3000 enclosure Care Pack services.
NOTE: SSAN/Fabric switches for the HP c-Class BladeSystem are not covered under
the c7000 and c3000 enclosure Care Packs, SAN/Fabric switches carry separate
Care Packs. SAN/Fabric Switch Care Pack service level support should always be
uplifted to match existing storage or server service level.
Hardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic
NOTE: Uplifts the Ethernet devices to the same level of service as the c-class
enclosure
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Installation & Start-up Services
HP BladeSystem c-Class Infrastructure Installation and Startup Service, Electronic
HP BladeSystem Enhanced Network Installation and Startup Service, Electronic
ProLiant BL c-Class Blade Server Hardware Installation, Electronic
ProLiant BL c-Class Enclosure and Server Blade Hardware Installation, Electronic
NOTE: For additional information; please visit:
http://www.hp.com/services/bladesystemservices
DA - 12597
Worldwide — Version 9 — February 29, 2008
444477-B21
444477-B22
444477-B23
444477-B27
UE458E
UE459E
UE460E
UE473E
UE477E
UE478E
UE479E
UE480E
UE602E
UE603E
UE493E
UE494E
Page 11
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Technical Specifications
Shipping Dimensions
Shipping Weight
Product Specifications
Hardware
Length
Width
Height
352.55mm (13.88 in)
270.00mm (10.63 in)
120.65mm (4.75 in)
2.0Kg (4.4lbs)
Performance
108 Gb total throughput
Non-blocking, line rate packet forwarding
Maximum transmission unit (MTU) of up to 9216 bytes (jumbo frames)
Connectors and Cabling Gigabit Ethernet uplink ports (Up to 10 external)
8 external 10/100/1000BASE-T RJ-45 ports.
2 external 10GBASE-CX4 (one additional internal 10Gb Cross Connect)
Indicators
Module locator (UID)
Module status
X1/X2 port status/locator
X1/X2 link/port activity
Port 1-8 port status/locator
Port 1-8 link/activity
Dimensions
Length
10.5in (267.7mm)
Width
7.5 in (92.79mm)
Height
1.1 in (27.94mm)
Weight
1.27Kg (2.8 Lbs)
Environmental Ranges
Temperature Range
Specification
10C to 35C (50F to 95F)
range*
Temperature range
Operating
10C to 35C (50F to 95F)
Shipping
Shipping -40C to 60C (-40F to 140F)
Storage
-20°C to 60°C (-4F to 140°F)
Maximum wet bulb
30C (80F)
temperature
Relative humidity
(noncondensing)**
Operating
10% to 90%
Shipping
10% to 90%
Storage
10% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per
1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is
3,048m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3
KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude
maximum for storage corresponds to a pressure minimum of 70 KPa.
12V @ 3A (36 W)
Power Specification
Product Specifications
Software
Security Features
DA - 12597
HTTPS (HTTP exchanged over an SSL-encrypted session) is required for
access to the Virtual Connect Manager.
Access to the Virtual Connect Manager is via the system Onboard
Worldwide — Version 9 — February 29, 2008
Page 12
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Technical Specifications
Trunking and Failover
Features
VLAN Features
Management Features
Administrator
Each user account can be configured for a combination of four access
privileges to control and/or view elements in the Virtual Connect Manager.
User verification by account name and password (Case Sensitive)
LDAP Authentication services provide role based security via an LDAP SSH
Directory Server connection.
Shared Uplink Sets using Link Aggregation Control Protocol (LACP) allows
the creation of Ethernet channeling with upstream switches that conform to
IEEE 802.3ad. Ports can alternatively be configured for failover only.
External ports within a Port Set can be on the same VC Ethernet module or
on multiple VC modules within the VC domain.
In the event of an uplink failure to a data center switch, the next highest
performance uplink connection or aggregation will become active.
Fast MAC Cache failover enables rapid recovery of network connections
when a standby module becomes active.
Smart Link network senses a failed upstream switch connection and allows
teamed NIC's to properly failover.
Configure uplink speeds to Auto,,10Mb, 100Mb, 1Gb,or10Gb on the
associated uplinks
802.1Q VLAN supported on uplinks
Uplink ports can be configured for VLAN tagging at egress or pass-thru of
tagged VLAN packets from Server ports
Native VLAN support for untagged packets on a shared uplink set. Packets
can be targeted to a specific server ports.
Simple and intuitive Graphical User Interface (GUI) for defining, configuring,
and managing all elements of the Virtual Connect Domain.
Setup Wizards for initial domain installation and configuration and network
configuration.
Comprehensive administration, definition, and management of Ethernet
Network, Shared Uplink Set, and Server Profiles
Embedded SNMP v1, v2 and SMI-S agents allow Network Management
applications to query Virtual Connect for statistics and trap information.
A robust, scriptable and secure Command Line Interface simplifies
management and enables macros to control common Virtual Connect tasks
Any uplink port can be used as a dedicated mirrored port for traffic analysis
and troubleshooting by a Network Analyzer or Sniffer.
Domain Management of user accounts, enclosure, Virtual Connect domain
settings, and firmware updates
The location and status of Virtual Connect Modules in the HP c-Class
Enclosure and Onboard Administrator can be viewed from the Hardware
Status page. Including at-a-glance detailed information of the hardware
elements via mouse-over pop-up windows.
MAC Address Administration allows local administration of predefined or
user-defined MAC address ranges.
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 13
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
QuickSpecs
Technical Specifications
VC manager runs as a high-availability pair when an HP 1/10Gb VC-Enet
Module is installed in adjacent bays. All configuration data is stored in flash
memory and checkpointed to the standby module. Configurations can also
be backed up to a workstation via the GUI.
Management and
Standards Support
Standards
IEEE 802.1Q
IEEE 802.3ac
IEEE 802.3ad (LACP)
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-X
IEEE 802.3ak 10GBASE-CX4
IGMP v1,v2,v3
SNMP v.1, v.2
Safety and
Compliance
Safety Certifications
UL/CUL Recognition to UL/CSA 60950-1
TUV to EN 60950-1
CB report and certificate to IEC 60950-1 with all country deviations
CE Marking
Electromagnetic
Emissions Certifications
FCC Part 15 Class A
FCC Part 15 Class A
EN 55022 Class A (CISPR22 Class A)
VCCI Class A
AS/NZS 3548 Class A or AS/NZS CISPR22 Class A
MIC Class A
CE Marking
Environment-friendly
Products and Approach
End-of-life Management
and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go to
http://www.hp.com/go/green. To recycle your product, please go to:
http://www.hp.com/go/green or contact your nearest HP sales office.
Products returned to HP will be recycled, recovered or disposed of in a
responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment facilities.
This information (product disassembly instructions) is posted on the Hewlett
Packard web site at: http://www.hp.com/go/green. These instructions may
be used by recyclers and other WEEE treatment facilities as well as HP OEM
customers who integrate and re-sell HP equipment.
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 14
QuickSpecs
HP 1/10Gb Virtual Connect Ethernet Module for c-Class
BladeSystem
Technical Specifications
© Copyright 2008 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
DA - 12597
Worldwide — Version 9 — February 29, 2008
Page 15