P.O. Box 27
4300 AA Zierikzee
The Netherlands
Tel. +31 111 413656
Fax. +31 111 416919
www.deltapowersupp lies.com
DELTA ELEKTRONIKA B.V.
SM 1500 - Series 1500 Watts DC POWER SUPPLIES
Models
Voltage range
Current range
SM 15-100
SM 35-45
SM 52-30
SM 52-AR-60
Autoranging output
SM 70-22
SM 120-13
SM 300-5
SM 400-AR-8
Autoranging output
0 - 15 V
0 - 35 V
0 - 52 V
0 - 26 V
0 - 52 V
0 - 70 V
0 - 120 V
0 - 300 V
0 - 200 V
0 - 400 V
0 - 100 A
0 - 45 A
0 - 30 A
0 - 60 A
0 - 30 A
0 - 22 A
0 - 13 A
0-5A
0-8A
0-4A
Features
•
cTUVus safety approval
•
Designed for long life at full power
•
Excellent dynamic response to load changes
•
Protected against all overload and short circuit conditions
•
EMC surpasses CE requirements:
low emission & high immunity
•
Low audible noise: fans are temperature controlled
•
Available options: High Speed Programming, Interfaces, Extra
Isolation, Sequencer, Digital Encoders, Power Sink etc.
Functionalities
•
Master/Slave parallel and series operation with
voltage and current sharing
•
Stacking is allowed, space between units is not
required
•
High power system configuration from multiple units
•
19" rack mounting or for laboratory use
(feet included)
•
Remote sensing
•
Interlock
DELTA ELEKTRONIKA BV
SM1500
Output
voltage
current
AUTORANGING (2 ranges)
max. output current / voltage
Input
AC single phase, 48 - 62 Hz
rated voltage range
rated frequency
SM 15-100
SM 35-45
0 - 15 V
0 - 100 A
no
-
0 - 35 V
0 - 45 A
no
-
SM 52-30 SM 52-AR-60 SM 70-22
0 - 52 V
0 - 30 A
no
-
0 - 52 V
0 - 60 A
yes
60 A / 0-26 V
30 A / 26-52 V
SM 120-13 SM 300-5 SM 400-AR-8
0 - 70 V
0 - 22 A
no
-
0 - 120 V
0 - 13 A
no
-
0 - 300 V
0-5A
no
-
0 - 400 V
0-8A
yes
8 A / 0-200 V
4 A / 200-400 V
90 - 265 V 90 - 265 V 90 - 265 V 90 - 265 V 90 - 265 V 90 - 265 V 90 - 265 V 90 - 265 V
100 - 240 V 100 - 240 V 100 - 240 V 100 - 240 V 100 - 240 V 100 - 240 V 100 - 240 V 100 - 240 V
50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Power Derating vs input:
90 V : Pout max (W), Iin (A)
100 V : Pout max (W), Iin (A)
110 V : Pout max (W), Iin (A)
1170,16
1317, 16
1492, 16
1185, 16
1334, 16
1498, 16
1200,16
1350,16
1505,16
1200,16
1350,16
1505,16
1200,16
1350,16
1505,16
1200,16
1350,16
1505,16
1200,16
1350,16
1500,16
1200,16
1350,16
1505,16
230 V : Pout max (W), Iin (A)
1500, 7.5
1575, 7.7
1560, 7.7
1560,7.7
1540, 7.6
1560, 7.7
1500, 7.4
1600, 7.8
power factor, 100%, 50% load
0.99, 0.98
0.99, 0.98
0.99, 0.98
0.99, 0.98
0.99, 0.98
0.99, 0.98
0.99, 0.98
0.99, 0.98
25 AT
12 W
22 W
25 AT
12 W
22 W
25 AT
12 W
22 W
25 AT
12 W
22 W
25 AT
12 W
22 W
25 AT
12 W
22 W
25 AT
12 W
22 W
25 AT
12 W
25 W
internal fuses
standby input power (Vo=Io=0)
standby input power (Vo=Vmax)
26 V / 52 V
Efficiency
AC 230 V input, full load
AC 115 V input, max. load
200 V / 400 V
87 %
83 %
90 %
86 %
90 %
86 %
89 / 90 %
84%
90 %
86 %
90 %
86 %
91 %
86 %
90 / 91%
86%
Load 0 - 100%
CV
Line 120 - 265 V AC
CV
(measured on sense block)
0.5 mV
0.2 mV
1 mV
0.5 mV
2 mV
0.7 mV
2 mV
0.7 mV
2.5 mV
1 mV
4 mV
2 mV
10 mV
3 mV
12 mV
4 mV
Load 0 - 100%
CC
Line 120 - 265 V AC
CC
(internal voltage sense)
5 mA
1 mA
3 mA
0.5 mA
1.5 mA
0.5 mA
2 mA
1 mA
1 mA
0.25 mA
0.6 mA
0.2 mA
0.5 mA
0.1 mA
0.5 mA
0.2 mA
CV
CV
2 mV
8 mV
1.8 mV
8 mV
2 mV
15 mV
2 mV
15 mV
3 mV
15 mV
7 mV
30 mV
7 mV
50 mV
15 mV
80 mV
CC
CC
15 mA
80 mA
5 mA
15 mA
3 mA
10 mA
10 / 3 mA
30 / 10 mA
3 mA
10 mA
2 mA
6 mA
0.5 mA
4 mA
1.2 / 0.6 mA
6 / 3 mA
Regulation
Ripple + noise
rms (BW=300 kHz)
p-p (BW=20 MHz)
rms (BW=300 kHz)
p-p (BW=20 MHz)
CC-ripple at full load
Temp. coeff., per °C
35.10-6
60.10-6
CV
CC
Stability
after 1 hr warm-up
during 8 hrs
6.10-5
9.10-5
CV
CC
tamb = 25 ± 1 °C, Vin = 230 V AC
(int. voltage sensing for CC-stab.)
Analog Programming
CV
CC
Programming inputs
input range
accuracy
offset
temp. coeff. offset
input impedance
0-5V
± 0.2%
- 0.1 ... +1.3 mV (on 5V)
10 µV / °C
> 1 MOhm
0-5V
± 0.5%
0 ... +2.2 mV (on 5V)
50 µV / °C
> 1 MOhm
Monitoring output
output range
accuracy
offset
temp. coeff. offset
output impedance
0-5V
± 0.2%
- 1... 0 mV (on 5V)
3 µV / °C
2 Ohm / max. 4 mA
0-5V
± 0.5%
- 1.1... 0 mV (on 5V)
60 µV / °C
2 Ohm / max. 4 mA
Reference voltage
on prog. connector
+12 V output
on prog. Connector
Relay Outputs
ACF
DCF
Page 1 - 2
Vref
TC
5.114 V ± 15 mV (Ro = 2 Ohm, max. 4 mA)
20 ppm
Vo
Imax
Ro
12 V ± 0.2 V
0.2 A
3 Ohm
AC - Fail
DC - Fail
1
)
both NO and NC contact
both NO and NC contact
SPECIFICATIONS
1
) output voltage ± 5% beyond set point
Rev. Sept. 2012
SM1500
DELTA ELEKTRONIKA BV
Status outputs
CC - status
LIM- status
OT
- status
PSOL - status
ACF
- status
DCF
- status
CC - operation
CV or CC limit
Over Temperature
Power Sink Overload
AC - Fail
DC - Fail 2)
5 V = logic 1
5 V = logic 1
5 V = logic 1
5 V = logic 1
5 V = logic 1
5 V = logic 1
2
) output voltage ± 5% beyond set point
with + 5V, 1 mA or relay contact
Remote ShutDown
contact at rear panel, see photo of rear panel on page 1-6
Interlock
Voltage meter, Ampere meter, AC-Fail, DC-Fail, Over Temperature, Power Sink Overload,
Remote-ShutDown, Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV- and CC- mode
Indicators (front panel)
Controls
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(front panel)
Mains on/off switch, CV-and CC-potmeter, CV- and CC-limit-potmeter, Display-Settings button, Display-Limits
button, Remote/Local button, Output On/Off button, Front panel Lock button.
Programming speed
SM 15-100
SM 35-45
SM 52-30 SM 52-AR-60 SM 70-22
SM 120-13
SM 300-5 SM 400-AR-8
0 → 15 V
6.1 ms
2.1 ms
0 → 35 V
15.4 ms
5.1 ms
0 → 52 V
7.3 ms
2.4 ms
0 → 26 V
8.5 ms
2.8 ms
0 → 70 V
13.2 ms
4.4 ms
0 → 120 V 0 → 300 V
3.4 ms
9 ms
2 ms
3.9 ms
-
-
-
0 → 52 V
34.2 ms
11 ms
-
15 → 0 V
6.1 ms
61 ms
35 → 0 V
14.7 ms
147 ms
52 → 0 V
7 ms
70 ms
26 → 0 V
8.2 ms
82 ms
70 → 0 V
12.9 ms
129 ms
-
-
-
52 → 0 V
33 ms
330 ms
-
SM 15-100
SM 35-45
Standard Version
Rise time (10 - 90%)
output voltage step
time, (100 % load)
time, (10 % load)
output voltage step
time, (100 % load)
time, (10 % load)
Fall time (90 - 10%)
output voltage step
time, (100 % load)
time, (10 % load)
output voltage step
time, (100 % load)
time, (10 % load)
Programming speed
High Speed Version
Rise time (10 - 90%)
output voltage step
time, (100 % load)
time, (10 % load)
output voltage step
time, (100 % load)
time, (10 % load)
Fall time (90 - 10%)
output voltage step
time, (100 % load)
time, (10 % load)
output voltage step
time, (100 % load)
time, (10 % load)
Ripple @full load
(rms/pp)
@full load
(rms/pp)
Output capacitance
SM 52-30 SM 52-AR-60 SM 70-22
Option P210 Option P211 Option P212
Option P213
0 → 35 V
0.27 ms
0.14 ms
0 → 52 V
0.31 ms
0.23 ms
0 → 26 V
0.44 ms
0.43 ms
0 → 70 V
0.47 ms
0.30 ms
-
-
-
0 → 52 V
0.53 ms
0.34 ms
-
15 → 0 V
0.21 ms
1.6 ms
35 → 0 V
0.33 ms
3.5 ms
52 → 0 V
0.38 ms
3.9 ms
26 → 0 V
0.27 ms
3.2 ms
70 → 0 V
0.78 ms
8.3 ms
-
-
-
52 → 0 V
1.0 ms
9.7 ms
-
26 V / 60 A
15/ 50 mV 50/115 mV 55 /135 mV 30 / 105 mV 45/150 mV
52 V / 30 A
25 / 90 mV
190 µF
91 µF
195 µF
-
120 → 0 V 300 → 0 V
3.3 ms
9 ms
33 ms
90 ms
SM 120-13
-
113 µF
0 → 120 V 0 → 300 V
0.46 ms
1.0 ms
0.27 ms
0.51 ms
-
-
120 → 0 V 300 → 0 V
0.51 ms
1.40 ms
4.5 ms
13 ms
20/80 mV
21 µF
0 → 400 V
15 ms
5 ms
200 → 0 V
3.5 ms
35 ms
400 → 0 V
14.2 ms
142 ms
SM 300-5 SM 400-AR-8
Option P214 Option P215 Option P216
0 → 15 V
0.20 ms
0.11 ms
390 µF
-
0 → 200 V
3.7 ms
2.6 ms
-
Option P217
0 → 200 V
0.35 ms
0.33 ms
0 → 400 V
0.98 ms
0.59 ms
200 → 0 V
0.35 ms
3.8 ms
400 → 0 V
1.7 ms
18 ms
200 V
25/115 mV 85 / 355 mV
400 V
60 / 245 mV
10 µF
7 µF
Notes: All specifications regarding programming speed are typical and measured on a resistive load.
Recovery time
recovery within
di/dt of load step
output voltage
time, @ 50 - 100% load step
max. deviation
@ 230 V AC input voltage
Output impedance
CV, 0-1 kHz
CV, 1-100 kHz
SM 15-100
SM 35-45
SM 52-30
50 mV
1.5 A/µs
14 V
100 µs
200 mV
50 mV
0.8 A/µs
30 V
100 µs
150 mV
100 mV
0.5 A/µs
48 V
100 µs
250 mV
26 V / 52 V
60 mV
1.0 / 0.5 A/µs
24 / 48 V
100 / 100 µs
200 / 100 mV
100 mV
0.4 A/µs
65 V
100 µs
200 mV
0.7 V
0.2 A/µs
110 V
100 µs
2.2 V
1.0 V
0.1 A/µs
280 V
100 µs
1.5 V
200 V / 400 V
1.0 / 0.5 V
0.2 / 0.1 A/µs
185 / 370 V
100 / 100 µs
2.5 / 1.5 V
< 1.3 mΩ
< 25 mΩ
< 1.7 mΩ
< 30 mΩ
< 3.5 mΩ
< 30 mΩ
< 3.3 mΩ
< 40 mΩ
< 7.5 mΩ
< 30 mΩ
< 63 mΩ
< 0.6 Ω
< 125 mΩ
<1Ω
< 83 mΩ
< 1.3 Ω
15 Arms
45 Apeak
13 Arms
30 Apeak
20 Arms
13 Arms
30 / 60 Apeak 22 Apeak
2.5 Arms
13 Apeak
1.2 Arms
5 Apeak
0.8 Arms
8 / 4 Apeak
Pulsating load
max. tolerable AC component
of load current
15 Arms
f > 1 kHz
100 Apeak
f < 1 kHz
Rev. Sept. 2012
SM 52-AR-60 SM 70-22 SM 120-13 SM 300-5 SM 400-AR-8
SPECIFICATIONS
Page 1 - 3
DELTA ELEKTRONIKA BV
SM1500
Insulation
1 input / output
creepage / clearance
3750 Vrms (1 min.)
8 mm
2500 Vrms
600 V DC
input / case
output / case
cTUVus / EN 60950 / EN 61010
Safety
EMC
Power Supply Standard
EN 61204-3,
Emission: residential, light industrial environment (CISPR22-Class B)
Immunity: industrial environment
Generic Emission
Generic Immunity
EN 61000-6-3, residential, light industrial environment (EN 55022 B)
EN 61000-6-2, industrial environment
− 20 to + 50 °C
derate output to 75% at 60 °C
Operating Temperature at full
load
max. 95% RH, non condensing, up to 40 °C
max. 75% RH, non condensing, up to 50 °C
Humidity
− 40 to + 85 °C
Storage temperature
Output shuts down in case of insufficient cooling
Thermal protection
500 000 hrs
MTBF
Hold-Up time
Vout = 100%,
Iout = 100%
Vout = 85%,
Iout = 100%
Vout = 100%,
Iout = 50%
@ 230 V AC input
16 ms
20 ms
36 ms
(time till DC-fail = 1)
Turn on delay
after mains switch on
480 ms @ 230 V AC,
27 A@115 V AC,
Inrush current
700 ms @ 115 V AC
22 A@230 V AC
Series operation
max. total voltage
Master / Slave operation
600 V
yes
Parallel operation
max. total current
Master / Slave operation
no limit
max. 4 units (including master)
Remote sensing
max. volt. drop per load lead
2V
adjust range
adjust range
0 - 102%
0 - 102%
Potentiometers & Encoders
front panel control with knobs
resolution
standard
0.03 %
Limits Voltage
Current
Option P001 (at front panel)
Option P220
screwdriver adjustment
digital encoders
SM 15-100
Meters
scale voltage
scale current
accuracy read output
read limit setting
(d = digit)
Mounting
Input Connector
SM 35-45
SM 52-30 SM 52-AR-60 SM 70-22
3.5 digit
3.5 digit
3.5 digit
0 - 15.00 V 0 - 35.0 V 0 - 52.0 V
0 - 100.0 A 0 - 45.0 A 0 - 30.0 A
0.5% + 2 d 0.5% + 2 d 0.5% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
3.5 digit
0 - 52.0 V
0 - 60.0 A
0.5% + 2 d
2% + 2 d
Cooling
audio noise level
airflow
M8 bolts
15 pole D-connector at rear panel (FEMALE)
Low noise blower, fan speed adapts to temperature of internal heatsink.
ca.45 dBA at full load, 25 °C ambient temperature, 1 m distance
ca. 50 dBA at full load, 50 °C ambient temperature, 1 m distance
from left to right
IP20
89 x 442 x 365 mm (feet removed)
89 x 483 mm (19", 2 U)
9.9 kg
Weight
Page 1 - 4
3.5 digit
0 - 400 V
0 - 8.00 A
0.5% + 2 d
2% + 2 d
IEC320/C20, EN 60320/C20
Enclosure
degree of protection
Dimensions
behind front panel: h x w x d
front panel: h x w
SM 300-5 SM 400-AR-8
Stacking of units allowed, air flow is from left to right.
Output Terminals
Programming connector
SM 120-13
3.5 digit
3.5 digit
3.5 digit
0 - 70.0 V 0 - 120.0 V 0 - 300 V
0 - 22.0 A 0 - 13.00 A 0 - 5.00 A
0.5% + 2 d 0.5% + 2 d 0.5% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
SPECIFICATIONS
Rev. Sept. 2012
SM1500
DELTA ELEKTRONIKA BV
Typical Applications
•
•
•
•
Solar inverter testing, PV-Simulation
Semiconductor burn-in & processing
Car test systems
ATE in industrial production lines
• Lasers
• Controlled battery (dis)charging
• Component device testing
• Driving PWM-controlled DC-motors
• Accurate current sources
• Aerospace and military equipment
Available Options
Two-Quadrant
Output: Power sink
High speed
programming
Increased
Output Power
The conservatively rated unit
allows to deliver extra output with
the same reliability.
At some derating, either the maximum output
voltage or the maximum output current can be
increased by about 10%.
A 10 to 20 times higher
programming speed (down to
0.2 ms rise time at full load)
and lower output capacitance.
Excellent for laser applications, test systems or
as current source with low parallel capacitance
as used in plasma chambers.
Two quadrant operations
maintains the output
voltage constant
regardless the output power is positive or
negative. Ideal for PWM-speed controlled
DC-motors and ATE systems.
• Order Code - P069
• Order Codes :
SM 15-100 P210
SM 35-45
P211
SM 52-30
P212
SM 52-AR-60 P213
• Order Codes :
SM 15-100 P202 - SM 52-AR-60 P205
SM 35-45 P203 - SM 70-22
P206
SM 52-30 P204
0,4ms
SM 70-22
P214
SM 120-13 P215
SM 300-5
P216
SM 400-AR-8 P217
Sequencer
High Voltage Isolation
Arbitrary Waveform generator or
standalone automation.
The sequencer is integrated in
the Ethernet controller.
A higher output isolation
allows series operation up to
1000V.
• Order Code - P177
• Order Code - P089
Digital Voltage and
Current Setting
Reliable, longlife digital encoders
can be implemented at the front
panel. Includes total front panel
lock (also for CV/CC-knobs) and
a coarse or fine pitch adjustment depending on
the turning speed.
• Order Code - P220
Note:
-
Secured Voltage
and Current Setting
For a maximum
security,the CV/CC
settings can be adjusted
with a screwdriver only and are protected
with a plastic cap from accidental
adjusting.
• Order Code - P001
Software Control and
Interfaces
Factory installed
programming interfaces:
•
•
•
•
•
•
Ethernet controller (incl.sequencer)
RS232 controller
IEEE488 controller
ISO AMP CARD - isolated analog
PROFIBUS controller
CANBUS controller
- P177
- P183
- P184
- P218
- P273
- P274
1. Download special datasheet about High Speed Program., Power Sink and Battery Charging from www.DeltaPowerSupplies.com.
2. There is only room for one of the interfaces in a unit (P177, P183, P184, P218, P273 or P274).
Rev. Sept. 2012
SPECIFICATIONS
Page 1 - 5
DELTA ELEKTRONIKA BV
SM1500
CV
CC
= Constant Voltage
= Constant Current
Specifications measured at
tamb = 25 ± 5 °C and Vin = 230 V AC,
50 Hz, unless otherwise noted.
The information in this document is
subject to change without notice
Connections programming connector
Ethernet or IEEE488 or isolated analog (all optional)
ETH user I/O, RS232 , CAN, PROFI (all optional)
Programming Connectors
Analog (standard)
Status
Relay
InterLock
Master / Slave
Line Cord
supplied
Sense Block
Output Terminals
Input Connector
Feet are not mounted
but included in packing
Safety Cover supplied for output (not shown)
Page 1 - 6
SPECIFICATIONS
Rev. Sept. 2012