PFXGP4603TAD
http://www.axcontrol.com/automation/pro-face/gp-4000/PFXGP4603TAD
Pro-face Xycom GP4000
PFXGP4603TAD
Pro-face Xycom GP-460xT GP460xT
Touch Screen Operator Interface 12.1 TFT Matrix Color LCD Display 24VDC. Call Now!
1-800-991-7026
sales@axcontrol.com
See Also:
http://www.axcontrol.com/automation/pro-face/gp-4000
GP4000 Series Hardware Manual
Part
Name
Description
F
SD Card Interface
Cover/Replacement Battery
Insertion Cover
For information on how to open the cover, and
insert or remove the SD Card, refer to SD Card
Insertion/Removal (see page 150).
For information on how to open the cover and
replace the battery, refer to Replacing the
Primary Battery (see page 168).
G
Serial Interface (COM2)
GP-4501T/GP-4501TW: RS-422/485 Serial
Interface. Connector: D-Sub 9 pin (plug) x 1.
GP-4503T: RS-485 (isolation) Serial Interface.
Connector: D-Sub 9 pin (socket) x 1.
H
Serial Interface (COM1)
RS-232C Serial Interface.
Connector: D-Sub 9 pin (plug) x 1.
I
USB (Type A) Interface
Conforms to USB2.0 (Type A) x 1. Power
supply voltage: 5Vdc+/-5%. Output Current:
500 mA or less. Maximum communication
distance: 5 m (16.4 ft).
*1
Status LED operations are as shown below:
Color
Indicator
Operation Mode
(Drawing)
Logic execution mode
(when logic is enabled)
Green
ON
Offline
–
In operation
RUN
STOP
Flashing
In operation
Orange
Flashing
Software starting up.
Red
ON
Power is turned ON.
Flashing
In operation
LED fade
(Green)
ON
The GP unit’s "Backlight Control" is set to Standby Mode
and the screen has gone blank.
-
OFF
Power is turned OFF.
*2
Major Error
SD Card Access LED operations are as shown below.
Color
Indicator
Description
Green (Active)
ON
The SD Card is inserted.
OFF
The SD Card is not inserted or is not
being accessed.
*3
Ethernet LED operations are as shown below.
Color
Indicator
Description
Green (Active)
Flashing
Data transmission is occurring.
OFF
No data transmission.
ON
Data transmission is available in
10BASE-T/100BASE-TX.
OFF
No connection or subsequent
transmission failure.
Link
Green (Link)
Active
39
Parts/Functions
GP-4600 Series Parts Identification
NOTE:
If you are using the rear mount model, refer to Parts Identification and Functions
(see page 176).
z
Side
GP-4600 Series
Front
A
Rear
B
C
B
I
Bottom
F
40
H
E
G
D
Part
Name
Description
A
Status LED
*1
B
Power Input Terminal Block
(AC model), Power Plug
Connector (DC model)
-
C
SD Card Access LED *2
This lamp lights up when SD Card is inserted.
NOTE: Do not remove or insert the SD Card
when the LED lamp is on. Doing so may
damage data on the SD Card.
D
Ethernet Interface *3
Ethernet transmission interface (10BASET/100BASE-TX)
Connector: Modular jack (RJ-45) x 1.
E
USB (mini-B) Interface
Conforms to USB2.0 (mini-B) x 1.
Communication Distance: 5 m (16.4 ft) or less.
GP4000 Series Hardware Manual
Part
Name
Description
F
SD Card Interface
Cover/Replacement Battery
Insertion Cover
For information on how to open the cover, and
insert or remove the SD Card, refer to SD Card
Insertion/Removal (see page 150).
For information on how to open the cover and
replace the battery, refer to Replacing the
Primary Battery (see page 168).
G
Serial Interface (COM2)
GP-4601T: RS-422/485 Serial Interface.
Connector: D-Sub 9 pin (plug) x 1.
GP-4603T: RS-485 (isolation) Serial Interface.
Connector: D-Sub 9 pin (socket) x 1.
H
Serial Interface (COM1)
RS-232C Serial Interface. Connector: D-Sub 9
pin (plug) x 1.
I
USB (Type A) Interface
Conforms to USB2.0 (Type A) x 1.
Power supply voltage: 5Vdc+/-5%.
Output Current: 500 mA or less.
Maximum communication distance: 5 m (16.4
ft).
*1
Status LED operations are as shown below:
Color
Indicator
Operation Mode
(Drawing)
Logic execution mode
(when logic is enabled)
Green
ON
Offline
–
In operation
RUN
Flashing
In operation
STOP
Orange
Flashing
Software starting up.
Red
ON
Power is turned ON.
Flashing
In operation
LED fade
(Green)
ON
The GP unit’s "Backlight Control" is set to Standby Mode
and the screen has gone blank.
-
OFF
Power is turned OFF.
*2
Major Error
SD Card Access LED operations are as shown below.
Color
Indicator
Description
Green (Active)
ON
The SD Card is inserted.
OFF
The SD Card is not inserted or is not
being accessed.
*3
Ethernet LED operations are as shown below.
Color
Indicator
Description
Green (Active)
Flashing
Data transmission is occurring.
OFF
No data transmission.
Green (Link)
ON
Data transmission is available in
10BASE-T/100BASE-TX.
OFF
No connection or subsequent
transmission failure.
Link
Active
41
Parts/Functions
42
GP4000 Series Hardware Manual
Specifications
KanpaiHardwareManual 10/2011
GP4000 Series Hardware Manual
Specifications
4
Overview
This chapter presents the GP unit specifications.
What Is in This Chapter?
This chapter contains the following sections:
Section
Topic
Page
4.1
GP-4200 Series
44
4.2
GP-4300 Series
64
4.3
GP-4400 Series
82
4.4
GP-4500 Series
97
4.5
GP-4600 Series
117
43
Specifications
4.1
GP-4200 Series
What Is in This Section?
This section contains the following topics:
Topic
44
Page
Electrical Specifications
45
Environmental Specifications
46
Structural Specifications
47
Display Specifications
49
Memory, Clock, and Touch Panel
50
Interface Specifications
52
Specifications of Serial Interface COM1
53
Specifications of Serial Interface COM2
57
Dimensions
58
GP4000 Series Hardware Manual
Power Supply
Electrical Specifications
Rated Input Voltage
24 Vdc
Input Voltage Limits
19.2...28.8 Vdc
Voltage Drop
2 ms or less
Power Consumption
In-Rush Current
9.6 W or less
When power is not supplied to
external devices
5.2 W or less
Backlight OFF (Standby Mode)
4.2 W or less
Backlight Dimmed (Brightness:
20%)
4.3 W or less
30 A or less
Voltage Endurance
1,000 Vac 20 mA for 1 minute
(between charging and FG
terminals)
Insulation Resistance
500 Vdc, 10 MΩ or more
(between charging and FG
terminals)
45
Specifications
Electrical Environment Mechanical Environment
Physical Environment
Environmental Specifications
Surrounding Air
Temperature
0...50 °C (32...122 °F)
Storage Temperature
-20...60 °C (-4...140 °F)
Surrounding Air and
Storage Humidity
10%...90% RH (Non condensing, wet bulb
temperature 39 °C [102.2 °F] or less)
Dust
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive
levels)
Pollution Degree
For use in Pollution Degree 2 environment
Corrosive Gases
Free of corrosive gases
Atmospheric Pressure
(Operating Altitude)
800...1,114 hPa (2,000 m [6,561 ft] or lower)
Vibration Resistance
IEC/EN 61131-2 compliant
5...9 Hz Single amplitude 3.5 mm (0.14 in.)
9...150 Hz Fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion Resistance
IEC/EN 61131-2 compliant
147 m/s2, X, Y, Z directions for 3 times
Noise immunity
Noise Voltage: 1,000 Vp-p
Pulse Width: 1 µs
Rise Time: 1 ns
Electrostatic Discharge
Immunity
Contact Discharge Method: 6 kV (IEC/EN 61000-42 Level 3)
Air quality requirements
Do not operate or store the panel where chemicals evaporate, or where chemicals
are present in the air:
z
z
Corrosive chemicals: Acids, alkalines, liquids containing salt.
Flammable chemicals: Organic solvents.
CAUTION
INOPERATIVE EQUIPMENT
Do not allow water, liquids, metal, and wiring fragments to enter the panel case.
Failure to follow these instructions can result in injury or equipment damage.
46
GP4000 Series Hardware Manual
Structural Specifications
Grounding
Functional grounding: Grounding resistance
of 100Ω, 2mm2 (AWG 14) or thicker wire, or
your country’s applicable standard. (Same
for FG and SG terminals)
Cooling Method
Structure
*1
Natural air circulation
IP65F NEMA #250 TYPE 4X/13 (on the front
panel when properly installed in an
enclosure)
External Dimensions
W132 x H106 x D42 mm (W5.2 x H4.17 x
D1.65 in.)
Panel Cut Dimensions
W118.5 x H92.5 mm (W4.67 x H3.64 in.)*2
Panel thickness area: 1.6...5 mm (0.06...0.2
in)*3
Weight
0.4 kg (0.9 lb) or less (main unit only)
*1
The front face of the GP unit, installed in a solid panel, has been tested using
conditions equivalent to the standards shown in the specification. Even though the
GP unit’s level of resistance is equivalent to these standards, oils that should have
no effect on the GP unit can possibly harm the panel. This can occur in areas where
either vaporized oils are present, or where low viscosity cutting oils are allowed to
adhere to the panel for long periods of time. If the GP unit’s front face protection
sheet peels off, these conditions can lead to the ingress of oil into the GP unit and
separate protection measures are suggested.
Also, if non-approved oils are present, they may cause deformation or corrosion of
the front panel’s plastic cover. Therefore, prior to installing the GP unit, be sure to
confirm the type of conditions that will be present in the GP unit’s operating
environment. If the installation gasket is used for a long period of time, or if the GP
unit and its gasket are removed from the panel, the original level of protection cannot
be kept. To maintain the original protection level, be sure to replace the installation
gasket regularly.
*2
For dimensional tolerance, everything +1/-0 mm (+0.04/-0 in.) and R in angle are
below R3 (R0.12 in.)
*3
Even if the installation wall thickness is within the recommended range for the
“Panel Cut Dimensions”, depending on wall’s material, size, and installation location
of the GP unit and other devices, the installation wall could warp. To prevent
warping, the installation surface may need to be strengthened.
The front face of the panel, installed in a solid panel, has been tested using
conditions equivalent to the standards shown in the specification.
CAUTION
EQUIPMENT DAMAGE
Ensure that the panel is not in permanent and direct contact with oils.
Failure to follow these instructions can result in injury or equipment damage.
47
Specifications
NOTICE
STORAGE AND OPERATION OUTSIDE OF SPECIFICATIONS
z
z
Store the panel in areas where temperatures are within the panel’s
specifications.
Do not restrict or block the panel’s rear-face ventilation slots.
Failure to follow these instructions can result in equipment damage.
NOTICE
GASKET AGING
z
z
Inspect the gasket periodically as required by your operating environment to
keep the initial IP level.
Change the gasket at least once a year, or as soon as scratches or dirt become
visible.
Failure to follow these instructions can result in equipment damage.
48
GP4000 Series Hardware Manual
Display Specifications
GP-4201T / GP-4203T
Display Type
TFT Color LCD
Display Size
3.5”
GP-4201TW
Resolution
320 x 240 pixels (QVGA)
Effective Display Area
W70.56 x H52.92 mm (W2.78 x H2.08 in.)
Display Colors
65,536 colors (No blink) / 16,384 colors (Blink)
Backlight
White LED (Not user replaceable. When
replacement is required, contact your local
distributor.)
Backlight Service Life
50,000 hours or more (continuous operation at 25 °C
[77 °F] before backlight brightness decreased to
50%)
Brightness Control
16 levels (Adjusted with
touch panel or software)
Language Fonts*1
Japanese, ASCII, Chinese (Simplified), Chinese
(Traditional), Korean, Cyrillic, Thai
Character Sizes
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel
fonts
Stroke font: 6...127 pixel fonts
Image font: 8...72 pixel fonts
Font Sizes
Standard font: You can expand width up to 8 times,
8 levels (Adjusted with
touch panel or software)
and expand height up to 8 times.*2
Text
8 x 8 pixels
40 characters per row x 30 rows
8 x 16 pixels
40 characters per row x 15 rows
16 x 16 pixels
20 characters per row x 15 rows
32 x 32 pixels
10 characters per row x 7 rows
*1
Please refer to the GP-Pro EX Reference Manual for details on font types and
character codes.
*2
You can set up other font sizes using the software.
49