Black Opal - Dallas Avionics, Inc.

Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
Specifications & Set-up
READ THIS DOCUMENT THOROUGHLY BEFORE
ATTEMPTING TO ASSEMBLE OR OPERATE
THE
Black Opal
Multi Function Flat Panel Display System
Model RMU10HX
Treatment of this product other than as specified herein may result in:
damage to the product or attached systems;
invalidation of the warranty.
The location of this document should always be known to all users of, and technical
support personnel for, the Black Opal RMU.
The information contained herein is proprietary to Laserdyne Pty Ltd. No part of this work may be
reproduced or copied in any way without prior written permission of Laserdyne Pty Ltd.
Note: specifications herein are subject to change without notice.
CAUTIONS:
•
User-supplied cables must be correctly wired (see Connector/Pin
Details).
•
Ensure that external power is within the range specified.
•
Ensure that external power is off before proceeding with set-up.
PS-RMU-M-0269-0_1
6.7.06
TW/TW
i
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
Tracking Records
This document is appropriate for the following product
configurations:
Model:
Black Opal Model:
RMU10HX.
Initial Installed Software Version:
PS-RMU-M-0269-0_1
6.7.06
TW/TW
4.5
ii
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
TABLE OF CONTENTS
Chapter
Page
1 SYSTEM SPECIFICATIONS
1.1 System Performance
1.2 Controls
1.3 Communications
1.4 Physical Characteristics
1.5 Electrical Requirements
1.6 Environmental
1.7 Connector/Pin Details
1-1
1-1
1-2
1-3
1-3
1-3
1-4
1-4
2 SET-UP
2.1 Mounts
2.2 Connections
2.3 Set-up Procedure
2.4 Heating and Cooling
2-1
2-1
2-1
2-2
2-3
LIST OF FIGURES
Figure 2-1:
Mounts
Figure 2-2:
Connections
2-1
2-2
PS-RMU-M-0269-0_1
6.7.06
TW/TW
iii
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
1
SYSTEM SPECIFICATIONS
1.1
System Performance
PARAMETER
SPECIFICATION
Designation
RMU10HX
Remote Monitor Unit, 10”, High
brightness, XGA
Control
Control Functions [factory configurable to
customer requirements]
Controls
power On/Off; backlight intensity;
menu select; select screen lay-out;
select image enhancement feature;
digital zoom; freeze frame
tactile 8-button membrane
Display
Type
diagonal
Display Size (″ {cm})
active area
Aspect Ratio [width:height]
Pixel Number [1 pixel is RGB trio]
Colour
Grey Scale
Backlight Luminance [CCFT type;
minimum
approx.; adjustable] (cdm-2) 1
maximum
Contrast Ratio [limiting; LCD]
Response Time [max.] (ms)
Readability [ambient conditions]
Active Matrix Colour (18-bit colour)
LCD Module
10.4 {26.42}
8.31 {21.1} x 6.24 {15.8}
4:3
1,024 x 768
262k [6-bit each colour]
256 [8-bit]
0
1,700
300:1
50
black-out to full direct sunlight
[105 lux]
Night Vision Device compatible?
Viewing Angle
vertical
horizontal
[full angle] (°)
yes [low intensity green]
+40/-35
±55
Inputs
Inputs
Signal Formats
video
PC
1
2 video and 1 PC [4 and 1 optional]
PAL [all forms], NTSC [all forms],
SECAM [all forms], CCIR-601, RS170;
interlaced and non-interlaced
non-interlaced, 60Hz, RGB, separate
Hsync. & Vsync., up to 1,024 x768
[standard PC XGA]
1 cdm-2 = 1 nit.
PS-RMU-M-0269-0_1
6.7.06
TW/TW
1-1
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
1.1
System Performance (cont’d)
PARAMETER
SPECIFICATION
Inputs (cont’d)
Connection Formats
video
PC
Composite, S-Video [Y-C]
RGB + Hsync. + Vsync.
Outputs
Video
prime video input is output [what
comes in goes out]
Safety & Protection
Cooling
thermal transfer by internal and
external convection; cooling fin fitted to
rear
purged & backfilled [N2]
Antireflection, hard-coated, sealed,
EMI/EMC shielded
pressure relief valve, 2-way
conforms to QSTAG 307
nil
Backfill
Display Window
Altitude/Decompression
Electrical Protection
Audible Emission [@ ≥ 10m]
Support
MTBF (hours)
Operational Life (years)
1.2
> 8,000
10
Controls
Control Type
Location
Primary Label
Primary Function
Button
membrane
on left of
top
Button
front face
2nd top
1
menu
Button
3rd top
2
show assigned screen
lay-outs for selection
Button
middle
3
enhance
Button
3rd bottom
4
zoom
Button
2nd bottom
5
freeze
Button
bottom left
-
backlight down;
scroll/adjust down
Button
bottom right
+
backlight up;
scroll/adjust up
PS-RMU-M-0269-0_1
6.7.06
TW/TW
toggle between active
and standby
1-2
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
1.3
Communications
PARAMETER
Ports
Data
1.4
SPECIFICATION
Format
Rate (Baud)
one Serial port 2
RS232 [RS422 optional]
9,600 [1,200 to 230.6k optional; or to
10 Mbaud for RS422]
Physical Characteristics
PARAMETER
Mass [approx.] (kg)
Dimensions Width
SPECIFICATION
body
281
(mm)
overall 3
307
body
211
4.7
Height
overall
3
Depth 4
96
Specific Gravity
Mounting 5
1.5
229
>1 [non-floatation]
Dzus fasteners x 6 [type PFSC35] or
or 2-way adjustable mounting bracket
optional
Electrical Requirements
PARAMETER
Supply Voltage (Vdc)
Current Drain
[@ 28Vdc; typical] (A)
SPECIFICATION
heater on
heater off
20 to 33 [28 nominal]
<3
<2
2
Shared with power input.
Including mounting flange.
4
Excluding connectors.
5
Optional 2-way adjustable mounting bracket has four ¼” clearance holes for mounting
3
PS-RMU-M-0269-0_1
6.7.06
TW/TW
1-3
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
1.6
Environmental
PARAMETER
Temperature (°C)
SPECIFICATION
Operate 6
min.
-25 [without wind-chill]
Survive
max.
min.
max.
+55 [without solar radiation]
-30 [without wind-chill]
+71 [without solar radiation]
MIL-STD-810E, aircraft 7
water resistant [drip & spray]
MIL-STD-461D 7
Vibration and Shock
Sealing 8
EMI/EMC 8
1.7
Connector/Pin Details
No.
Name
Pin
Marking
Purpose
Notes for
Harness
Comment
A: VGA Input: Connector, MilSpec, Mil-C26482, Panel, Plug, Bayonet, 19 Way, 14 Shell, Pattern 105,
square flange, AB05 2100 14-19P N00
A1
RED OUT
A
N/A
A2
RED IN
B
RED INPUT
A3
GREEN OUT
C
N/A
A4
GREEN IN
D
GREEN INPUT
A5
BLUE OUT
E
N/A
A6
BLUE IN
F
BLUE INPUT
A7
HS OUT
G
N/A
A8
HS IN
H
HSYNC INPUT
coax (B,P), 75Ω DB15 pin 1. Also Pr
input for component
video
coax (D,R), 75Ω DB15 pin 2. Also Y
(and SOG) input for
component video
coax (F,S), 75Ω DB15 pin 3. Also Pb
input for component
video
signal wire
DB15 pin 13
A9
VS OUT
J
N/A
A10
VS IN
K
VSYNC INPUT
signal wire
DB15 pin 14
A11
DDC_5V
L
DDC CHANNEL +5V
unused
DB15 pin 9
A12
DDC_SDA
M
DDC CHANNEL DATA
unused
DB15 pin 12
A13
DDC_SCL
N
DDC CHANNEL CLOCK unused
DB15 pin 15
6
When used in accordance with procedures in User’s Manual.
Contact supplier for details.
8
With compliant line connectors attached.
7
PS-RMU-M-0269-0_1
6.7.06
TW/TW
1-4
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
1.7
Connector/Pin Details (cont’d)
No.
Name
Pin
Marking
Purpose
Notes for
Harness
Comment
A: VGA Input (cont’d)
A14
RED GND
P
A15
GREEN GND
R
GREEN coax GND
coax braid
DB15 pin 7
A16
BLUE GND
S
BLUE coax GND
coax braid
DB15 pin 8
A17
DIGITAL GND
T
HSYNC GND
signal wire
DB15 pin 5
A18
DIGITAL GND
U
VSYNC GND
signal wire
DB15 pin 10
A19
N/C
V
UNUSED
unused
DB15 pin 4,11
RED coax GND
coax braid
DB15 pin 6
B: Video Input: Connector, MilSpec, Mil-C26482, Panel, Socket, Bayonet, 19 Way, 14 Shell, Pattern
105, square flange, AB05 2100 14-19S N00
B1
Y1_GND
A
Primary video
(composite or luma)
GND
coax, 75Ω
shield
B2
Y1_SIGNAL
B
Primary video
(composite or luma)
input
coax, 75Ω
center
B3
Y2_GND
C
Secondary video
(composite or Y) GND
coax, 75Ω
shield
B4
Y2_SIGNAL
D
Secondary video
(composite or Y) input
coax, 75Ω
center
B5
RS485+
E
RS485+ connection
signal
B6
RS485-
F
RS485- connection
signal
B7
V-
G
dc- (GND) connection
5A dc
internally isolated
from comms and
video GND.
B8
V+
H
Output power (+28V)
5A dc
Same as input dc
B9
V+
J
Output power (+28V)
5A dc
Same as input dc
B10
VIDEO_OUT
K
Switched video output
coax, 75Ω
center
either Y1 or Y2
output, 75Ω double
terminated
B11
GND_OUT
L
Video output GND
coax, 75Ω
shield
B12
SPARE1
M
Analogue input
signal
B13
SPARE2
N
Analogue input
signal
SPARE2
B14
C1_SIGNAL
P
Primary chroma input
[or VCR composite
input]
coax, 75Ω
center
75Ω terminated in
display
B15
C2_SIGNAL
R
Secondary chroma
input
coax, 75Ω
center
75Ω terminated in
display
PS-RMU-M-0269-0_1
6.7.06
TW/TW
75Ω terminated in
display
75Ω terminated in
display
SPARE1
1-5
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
1.7
Connector/Pin Details (cont’d)
No.
Name
Pin
Marking
Purpose
Notes for
Harness
Comment
B: Video Input (cont’d)
B16
C_GND
S
Chroma common [or
VCR composite input]
coax, 75Ω
shield
B17
V-
T
dc- (GND) connection
5A dc
B18
RS232_TX
U
RS232 transmit
(output from display)
signal
B19
RS232_RX
V
RS232 receive (input
to display)
signal
internally isolated
from comms and
video GND.
C: dc Power Input & Comms Port Connection: Connector, MilSpec, Mil-C26482, Panel, Plug, Bayonet,
12 Way, 14 Shell, Pattern 105, square flange, AB05 2100 14-12P N00
C1
COMMS_GND
C2
N/C
B
unused
C3
RS232_RX
C
RS232 receive (input
to display)
signal
C4
RS232_TX
D
RS232 transmit
(output from display)
signal
C5
nRESET
E
active low display
reset control
reserved
C6
MODAB
F
active low display
bootload control
reserved
C7
RS485-
G
RS485- connection
reserved
C8
RS485+
H
RS485+ connection
reserved
C9
V-
J
dc- (GND) connection
5A dc
internally isolated
from comms and
video GND.
C10
V-
K
dc- (GND) connection
5A dc
internally isolated
from comms and
video GND.
C11
V+
L
Input power (+28V)
for display
5A dc
+20..+33V input
C12
V+
M
Input power (+28V)
for display
5A dc
+20..+33V input
PS-RMU-M-0269-0_1
A
6.7.06
common for comms
TW/TW
signal
1-6
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
2
SET-UP
2.1
Mounts
The RMU has two optional mounting methods:
six type PFSC35 Dzus fasteners, located on the left and right (three per
side) of the mounting flange; or
a 2-way adjustable mounting bracket fitted to the RMU.
In the case of the 2-way adjustable mounting bracket, four mounting points are
provided, being ¼” diameter clearance holes located in the top section of the
bracket.
mounting
points
Figure 2-1: Mounts
2.2
Connections
The RMU has three connection points located on the rear of the unit:
Connector A, the VGA Input connector;
Connector B, the Video Input connector; and
Connector C, the dc Power Input & Comms Port connector.
PS-RMU-M-0269-0_1
6.7.06
TW/TW
2-1
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
Connector C, Power
Input & Comms (12
way)
Pressure Relief
Valve
Connector B, Video
Input (19 way)
Connector A, VGA
Input (19 way)
Figure 2-2: Connections
2.3
Set-up Procedure
CAUTION:
User-supplied cables must be correctly wired (see list of
Connector/Pin Details).
Ensure that external power is within the range specified
herein.
Ensure that external power is OFF before proceeding with
set-up.
•
Mount the unit to the vehicle or platform, using the six Dzus fasteners provided.
•
Connect the required video cable to Connector B and to the external imaging
system(s).
•
Connect the required VGA cable to Connector A and to the external VGA source.
•
Connect the required power/data cable to Connector C and to the external power
source, and to the communication data source (RS232).
PS-RMU-M-0269-0_1
6.7.06
TW/TW
2-2
Specifications & Set-up:
Black Opal Model RMU10HX
Flat Panel Display System
2.4
Heating and Cooling
The unit contains internal heating and cooling mechanisms that are triggered at
certain internal temperatures.
The operating procedures, internal temperatures and resulting operating conditions
are shown in the following table.
Ambient
Temp. (°C)
Procedure
< -46
do not attempt to operate
unit
-46 to 0
de-ice unit prior to start-up
0 to +55
Internal
Temp. (°C)
Operating Condition
≤0
unit will not power up;
heater on
>0
unit will power up;
internal convection on
≥ 10
heater off
≥ 55
backlight reduces
≥ 75
unit will not power up
none
+55 to +60
provide forced air cooling
(e.g. fan)
> +60
do not attempt to operate
unit
The approximate warm-up rate is 17s/°C (e.g. with starting internal temperature of 46°C, unit will power up in about 13 minutes; with starting internal temperature of 25°C, unit will power up in about 7 minutes).
Once the unit has warmed it will operate normally provided that the ambient
temperature stays within the specified operating temperature range. Otherwise the
heater will remain on.
T:\PROD&PRO\SPECS\PS-RMU-M-0269-0_1
6.7.06
TW/TW