HP ProLiant Smart Array E200 Specifications

HP ProLiant BL460c Server Blade
Maintenance and Service Guide
Part Number 405778-401
November 2008 (Tenth Edition)
© Copyright 2006, 2008 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Intended audience
This guide is for an experienced service technician. HP assumes you are qualified in the servicing of
computer equipment and trained in recognizing hazards in products with hazardous energy levels and
are familiar with weight and stability precautions for rack installations.
Contents
Customer self repair ...................................................................................................................... 5
Parts only warranty service ......................................................................................................................... 5
Illustrated parts catalog ............................................................................................................... 16
Server blade components ......................................................................................................................... 16
Removal and replacement procedures ........................................................................................... 22
Required tools......................................................................................................................................... 22
Safety considerations ............................................................................................................................... 22
Preventing electrostatic discharge .................................................................................................... 22
Server blade warnings and cautions ................................................................................................ 22
Symbols on equipment ................................................................................................................... 23
Server blade preparation ......................................................................................................................... 23
Power down the server blade .......................................................................................................... 24
Remove the server blade ................................................................................................................ 24
Access panel .......................................................................................................................................... 25
Hard drive blank ..................................................................................................................................... 26
Hard drive.............................................................................................................................................. 26
FBDIMM ................................................................................................................................................ 28
Hard drive backplane .............................................................................................................................. 29
Hard drive backplane retainer .................................................................................................................. 30
Front panel/hard drive cage assembly....................................................................................................... 31
Mezzanine card...................................................................................................................................... 32
HP Smart Array E200i Controller cache module .......................................................................................... 33
HP Smart Array E200i Controller battery pack ............................................................................................ 34
Server blade handle ................................................................................................................................ 35
Release button ........................................................................................................................................ 36
Heatsink................................................................................................................................................. 37
Processor ............................................................................................................................................... 39
System board ......................................................................................................................................... 44
System battery ........................................................................................................................................ 49
Diagnostic tools .......................................................................................................................... 51
Troubleshooting resources ........................................................................................................................ 51
HP Insight Diagnostics.............................................................................................................................. 51
HP Insight Diagnostics survey functionality .................................................................................................. 51
Integrated Management Log ..................................................................................................................... 52
Array Diagnostic Utility ............................................................................................................................ 52
HP Systems Insight Manager ..................................................................................................................... 52
HP Instant Support Enterprise Edition.......................................................................................................... 53
Web-Based Enterprise Service .................................................................................................................. 53
Open Services Event Manager.................................................................................................................. 53
Server component identification.................................................................................................... 54
Front panel components ........................................................................................................................... 54
Front panel LEDs ..................................................................................................................................... 55
SAS and SATA hard drive LEDs................................................................................................................. 56
Contents
3
SAS and SATA hard drive LED combinations .............................................................................................. 56
System board components........................................................................................................................ 57
Mezzanine connector definitions ..................................................................................................... 58
FBDIMM slot numbering ................................................................................................................. 58
System maintenance switch............................................................................................................. 58
Hard drive backplane components ............................................................................................................ 59
HP c-Class Blade SUV Cable..................................................................................................................... 60
Specifications ............................................................................................................................. 61
Environmental specifications ..................................................................................................................... 61
Server blade specifications ....................................................................................................................... 61
Acronyms and abbreviations........................................................................................................ 62
Index......................................................................................................................................... 64
Contents
4
Customer self repair
HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow
for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP
service providers or service partners) identifies that the repair can be accomplished by the use of a CSR
part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:
•
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these
parts, you will be charged for the travel and labor costs of this service.
•
Optional—Parts for which customer self repair is optional. These parts are also designed for
customer self repair. If, however, you require that HP replace them for you, there may or may not be
additional charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer
warranty, HP requires that an authorized service provider replace the part. These parts are identified as
"No" in the Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day
delivery. Same day or four-hour delivery may be offered at an additional charge where geography
permits. If assistance is required, you can call the HP Technical Support Center and a technician will help
you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a
defective part must be returned to HP. In cases where it is required to return the defective part to HP, you
must ship the defective part back to HP within a defined period of time, normally five (5) business days.
The defective part must be returned with the associated documentation in the provided shipping material.
Failure to return the defective part may result in HP billing you for the replacement. With a customer self
repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.
For more information about HP's Customer Self Repair program, contact your local service provider. For
the North American program, refer to the HP website (http://www.hp.com/go/selfrepair).
Parts only warranty service
Your HP Limited Warranty may include a parts only warranty service. Under the terms of parts only
warranty service, HP will provide replacement parts free of charge.
For parts only warranty service, CSR part replacement is mandatory. If you request HP to replace these
parts, you will be charged for the travel and labor costs of this service.
Réparation par le client (CSR)
Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client)
afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant
la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut
être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces
CSR:
Customer self repair 5
•
Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à
HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront
facturés.
•
Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont
également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous
demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type
de garantie applicable à votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la
réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit
effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue
illustré.
Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre
situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le
jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance
téléphonique, appelez le Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de
rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous
devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation
doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se
réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte
l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à
utiliser.
Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus
d'informations sur ce programme en Amérique du Nord, consultez le site Web HP
(http://www.hp.com/go/selfrepair).
Service de garantie "pièces seules"
Votre garantie limitée HP peut inclure un service de garantie "pièces seules". Dans ce cas, les pièces de
rechange fournies par HP ne sont pas facturées.
Dans le cadre de ce service, la réparation des pièces CSR par le client est obligatoire. Si vous demandez
à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti
difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente
dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di
assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente
al cliente per la sostituzione. Vi sono due categorie di parti CSR:
•
Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida
la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
•
Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di
componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP,
potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
Customer self repair 6
NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare
la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti
sono identificate da un "No" nel Catalogo illustrato dei componenti.
In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il
giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un
supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di
un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP
specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente
difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni
lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di
spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio
da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e
resa e sceglie il corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il
programma in Nord America fare riferimento al sito Web HP (http://www.hp.com/go/selfrepair).
Servizio di garanzia per i soli componenti
La garanzia limitata HP può includere un servizio di garanzia per i soli componenti. Nei termini di
garanzia del servizio per i soli componenti, HP fornirà gratuitamente le parti di ricambio.
Per il servizio di garanzia per i soli componenti è obbligatoria la formula CSR che prevede la riparazione
da parte del cliente. Se il cliente invece richiede la sostituzione ad HP, dovrà sostenere le spese di
spedizione e di manodopera per il servizio.
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und
höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP
Servicepartner) bei der Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden
kann, sendet Ihnen HP dieses Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien
unterteilt:
•
Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie
den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten
für diesen Service berechnet.
•
Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für
Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen
lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen
Garantiebedingungen zusätzliche Kosten anfallen.
HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog
sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag
geliefert. Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen
einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center
Customer self repair 7
anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSRErsatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden
muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines
vorgegebenen Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss
mit der zugehörigen Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang
enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung
stellen. Im Falle von Customer Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf
und bestimmt den Kurier-/Frachtdienst.
Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner
vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter
(http://www.hp.com/go/selfrepair).
Parts-only Warranty Service (Garantieservice
ausschließlich für Teile)
Ihre HP Garantie umfasst möglicherweise einen Parts-only Warranty Service (Garantieservice
ausschließlich für Teile). Gemäß den Bestimmungen des Parts-only Warranty Service stellt HP Ersatzteile
kostenlos zur Verfügung.
Für den Parts-only Warranty Service ist das CSR-Verfahren zwingend vorgegeben. Wenn Sie den
Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen
Service berechnet.
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer
Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de
realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los
proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el
uso de un componente CSR, HP le enviará dicho componente directamente para que realice su
sustitución. Los componentes CSR se clasifican en dos categorías:
•
Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si
solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los
gastos de desplazamiento y de mano de obra de dicho servicio.
•
Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos
componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo,
si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del
tipo de servicio de garantía correspondiente al producto.
NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para
que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios
autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra
"No" en el catálogo ilustrado de componentes.
Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a
su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega
en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al
Customer self repair 8
Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de
materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos
deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP,
deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los
componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje
de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En
el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío
y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.
Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase
en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica,
visite la página web de HP siguiente (http://www.hp.com/go/selfrepair).
Servicio de garantía exclusivo de componentes
La garantía limitada de HP puede que incluya un servicio de garantía exclusivo de componentes. Según
las condiciones de este servicio exclusivo de componentes, HP le facilitará los componentes de repuesto
sin cargo adicional alguno.
Para este servicio de garantía exclusivo de componentes, es obligatoria la sustitución de componentes
por parte del usuario (CSR). Si solicita a HP que realice la sustitución de estos componentes, tendrá que
hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze
onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner)
bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP
dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee
categorieën CSR-onderdelen:
•
Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze
onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening
gebracht.
•
Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn
ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te
vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type
garantieservice voor het product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband
met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden
vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de
eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden
aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service
Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het
vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte
onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde
Customer self repair 9
periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de
bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het
defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen.
Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde
onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma
van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair).
Garantieservice "Parts Only"
Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen
van de Parts Only garantieservice zal HP kosteloos vervangende onderdelen ter beschikking stellen.
Voor de Parts Only garantieservice is vervanging door CSR-onderdelen verplicht. Als u HP verzoekt deze
onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening
gebracht.
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a
minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se,
durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o
reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao
cliente. Existem duas categorias de peças CSR:
•
Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua
essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
•
Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas
para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a
cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de
cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão
identificadas com a marca "No" (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após
o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode
ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte
técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a
peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for
necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente
cinco (5) dias úteis. A peça com defeito deve ser enviada com a documentação correspondente no
material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de
reparo feito pelo cliente, a HP paga todas as despesas de transporte e de devolução da peça e
determina a transportadora/serviço postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com
o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP
(http://www.hp.com/go/selfrepair).
Customer self repair 10
Serviço de garantia apenas para peças
A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segundo os termos
do serviço de garantia apenas para peças, a HP fornece as peças de reposição sem cobrar nenhuma
taxa.
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas
peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Customer self repair 11
Customer self repair 12
Customer self repair 13
Customer self repair 14
Customer self repair 15
Illustrated parts catalog
Server blade components
Item
Description
Spare part
number
Customer self repair
(on page 5)
Mechanical components
1
Access panel
410303-001
Mandatory1
2
Hard drive blank
392613-001
Mandatory1
System components
3
Front panel/hard drive cage assembly with front
panel LED/board
410301-001
Mandatory1
4
Processors
—
—
a) 3.00-GHz Intel® Xeon® processor 5050, dual- 409423-001
core, 2×2-MB cache, 667-MHz FSB**
Optional2
b) 3.20-GHz Intel® Xeon® processor 5060, dual- 409424-001
core, 2×2-MB cache, 1066-MHz FSB* **
Optional2
Illustrated parts catalog 16
Item
Description
Spare part
number
Customer self repair
(on page 5)
c) 3.20-GHz Intel® Xeon® processor 5063 MV,
dual-core, 2×2-MB cache, 1066-MHz FSB* **
413073-001
Optional2
d) 3.73-GHz Intel® Xeon® processor 5080, dual- 412955-001
core, 2×2-MB cache, 1066-MHz FSB* **
Optional2
e) 1.60-GHz Intel® Xeon® processor 5110, dual- 416795-001
core, 4-MB cache, 1066-MHz FSB* **
Optional2
f) 1.86-GHz Intel® Xeon® processor 5120, dualcore, 4-MB cache, 1066-MHz FSB* **
416794-001
Optional2
g) 2.00-GHz Intel® Xeon® processor 5130, dual- 416796-001
core, 4-MB cache, 1333-MHz FSB* **
Optional2
h) 2.33-GHz Intel® Xeon® processor 5140, dual- 416797-001
core, 4-MB cache, 1333-MHz FSB* **
Optional2
i) 2.33-GHz Intel® Xeon® processor 5148, dualcore, 4-MB cache, 1066-MHz FSB* **
431716-001
Optional2
j) 2.66-GHz Intel® Xeon® processor 5150, dualcore, 4-MB cache, 1333-MHz FSB* **
416798-001
Optional2
k) 3.00-GHz Intel® Xeon® processor 5160, dual- 416799-001
core, 4-MB cache, 1333-MHz FSB* **
Optional2
l) 1.86-GHz Intel® Xeon® processor E5205,
dual-core, 6-MB L2 cache, 1066-MHz FSB* **
460493-001
Optional2
m) 3.00-GHz Intel® Xeon® processor L5240,
dual-core, 6-MB L2 cache, 1333-MHz FSB* **
459739-001
Optional2
n) 3.33-GHz Intel® Xeon® processor X5260,
dual-core, 6-MB L2 cache, 1333-MHz FSB* **
459738-001
Optional2
o) 1.60-GHz Intel® Xeon® processor E5310,
quad-core, 2×4-MB cache, 1066-MHz FSB* **
437945-001
Optional2
p) 1.86-GHz Intel® Xeon® processor E5320,
quad-core, 2×4-MB cache, 1066-MHz FSB* **
436151-001
Optional2
q) 2.00-GHz Intel® Xeon® processor E5335,
quad-core, 2×4-MB cache, 1333-MHz FSB* **
437946-001
Optional2
r) 2.33-GHz Intel® Xeon® processor E5345,
quad-core, 2×4-MB cache, 1333-MHz FSB* **
439827-001
Optional2
s) 2.66-GHz Intel® Xeon® processor X5355,
quad-core, 2×4-MB cache, 1333-MHz FSB* **
438363-001
Optional2
t) 2.00-GHz Intel® Xeon® processor E5405,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
457876-001
Optional2
u) 2.33-GHz Intel® Xeon® processor E5410,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
460492-001
Optional2
v) 2.33-GHz Intel® Xeon® processor L5410,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
459736-001
Optional2
Illustrated parts catalog 17
Item
Description
Spare part
number
Customer self repair
(on page 5)
w) 2.50-GHz Intel® Xeon® processor E5420,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
460491-001
Optional2
x) 2.50-GHz Intel® Xeon® processor L5420,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
463719-001
Optional2
y) 2.66-GHz Intel® Xeon® processor E5430,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
457877-001
Optional2
z) 2.83-GHz Intel® Xeon® processor E5440,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
460490-001
Optional2
aa) 3.00-GHz Intel® Xeon® processor E5450,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
457878-001
Optional2
bb) 3.00-GHz Intel® Xeon® processor X5450,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
462801-001
Optional2
cc) 3.16-GHz Intel® Xeon® processor X5460,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
457879-001
Optional2
dd) 3.33-GHz Intel® Xeon® processor X5470,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
497545-001
Optional2
ee) 2.66-GHz Intel® Xeon® processor X5430,
quad-core, 2×6-MB L2 cache, 1333-MHz FSB*
**
459735-001
Optional2
ff) 3.50-GHz Intel® Xeon® processor X5270,
dual-core, 6-MB L2 cache, 1333-MHz FSB* **
497546-001
Optional2
5
Heatsink
410304-001
Optional2
6
Hard drives
—
—
a) 36-GB, SAS, SFF, 10,000-rpm
376596-001
Mandatory1
b) 72-GB, SAS, SFF, 10,000-rpm*
376597-001
Mandatory1
c) 60-GB, SATA, SFF, 5,400-rpm*
405419-001
Mandatory1
FBDIMMs
—
—
a) 512-MB, PC2-5300
416470-001
Mandatory1
b) 1-GB, PC2-5300*
416471-001
Mandatory1
c) 1-GB, PC2-5300, low-power, RoHS*
462837-001
Mandatory1
d) 2-GB, PC2-5300*
416472-001
Mandatory1
e) 2-GB, PC2-5300, low-power, RoHS*
455442-001
Mandatory1
f) 4-GB, PC2-5300*
416473-001
Mandatory1
Boards
7
Illustrated parts catalog 18
Item
Description
Spare part
number
Customer self repair
(on page 5)
g) 4-GB, PC2-5300, low-power, RoHS*
467654-001
Mandatory1
h) 8-GB, PC2-5300*
416474-001
Mandatory1
8
Hard drive backplane
410300-001
Optional2
9
System board
—
Optional2
a) System board (dual-core processor support)
410299-001
Optional2
b) System board (quad-core processor support)*
438249-001
Optional2
Battery-backed write cache components
—
—
a) Smart Array E200i Controller cache module,
64-MB*
412800-001
Mandatory1
b) Smart Array E200i Controller cache module,
128-MB*
351518-001
Mandatory1
c) Smart Array E200i Controller battery pack*
307132-001
Mandatory1
10
Miscellaneous
11
System battery*
234556-001
Optional2
12
HP c-Class Blade SUV Cable (Local I/O cable)*
416003-001
Mandatory1
13
Fibre Channel mezzanine*
—
—
a) Emulex LPe1105 FC Mezzanine HBA for HP cClass BladeSystem
405921-001
Mandatory1
b) Qlogic QMH2462 FC Mezzanine HBA for HP
c-Class BladeSystem
405920-001
Mandatory1
Standard NIC mezzanine*
—
—
a) HP NC326m PCIe Dual Port 1 Gb HBA for HP
c-Class BladeSystem
419330-001
Mandatory1
b) HP NC373m PCIe Dual Port Multifunction 1Gb 430548-001
HBA for HP c-Class BladeSystem
Mandatory1
Hardware and plastics kit*
410302-001
Mandatory1
a) Heatsink blank
—
—
b) Mezzanine connector covers (2)
—
—
c) Processor socket cover
—
—
d) Hard drive backplane retainer
—
—
Server blade handle kit*
434104-001
Optional2
a) Server blade handle
—
—
b) Release button
—
—
c) Server blade handle screw, T-15
—
—
d) Release button screws, T-15 (2)
—
—
e) Server blade handle nut
—
—
14
15
16
*Not shown
**Do not mix processors with different speeds or cache sizes.
Illustrated parts catalog 19
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be
charged for the travel and labor costs of this service.
2
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If,
however, you require that HP replace them for you, there may or may not be additional charges, depending on the
type of warranty service designated for your product.
3
No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires
that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts
Catalog.
1
Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP
de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
2
Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également
conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer
ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
3
No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour
que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé.
Ces pièces sont identifiées par la mention “Non” dans le Catalogue illustré.
1
Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la
riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
2
Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti
progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese
addizionali a seconda del tipo di garanzia previsto per il prodotto.
3
No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la
garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono
identificate da un “No” nel Catalogo illustrato dei componenti.
1
Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn
Sie diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet.
2
Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für
Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten,
können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten
anfallen.
3
No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu
erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit
„No“ bzw. „Nein“ gekennzeichnet.
1
1
Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a
HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de
mano de obra de dicho servicio.
2
Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional. Estos
componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que
HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía
correspondiente al producto.
3
No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el
usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la
sustitución de estos componentes. Dichos componentes se identifican con la palabra “No” en el catálogo ilustrado de
componentes.
Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen
te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2
Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn
ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen
daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
1
Illustrated parts catalog 20
No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de
garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze
onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
3
Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas
peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
2
Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o
reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa
adicional, dependendo do tipo de serviço de garantia destinado ao produto.
3
No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a
garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a
marca “No” (Não), no catálogo de peças ilustrado.
1
Illustrated parts catalog 21
Removal and replacement procedures
Required tools
You need the following items for some procedures:
•
T-15 Torx screwdriver (provided inside the access panel)
•
HP Insight Diagnostics software ("HP Insight Diagnostics" on page 51)
Safety considerations
Before performing service procedures, review all the safety information.
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the
system or handling parts. A discharge of static electricity from a finger or other conductor may damage
system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the
device.
To prevent electrostatic damage:
•
Avoid hand contact by transporting and storing products in static-safe containers.
•
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
•
Place parts on a grounded surface before removing them from their containers.
•
Avoid touching pins, leads, or circuitry.
•
Always be properly grounded when touching a static-sensitive component or assembly.
Server blade warnings and cautions
WARNING: To reduce the risk of shock or injury from high-current electrical energy, do not
remove the server blade access panel and then install the server blade into the enclosure.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: Do not operate the server blade with the access panel removed. Operating the
server blade in this manner results in improper airflow and improper cooling that can lead to
thermal damage.
Removal and replacement procedures 22
CAUTION: When performing non-hot-plug operations, you must power down the server blade
and/or the system. However, it may be necessary to leave the server blade powered up when
performing other operations, such as hot-plug installations or troubleshooting.
Symbols on equipment
The following symbols may be placed on equipment to indicate the presence of potentially hazardous
conditions.
This symbol indicates the presence of hazardous energy circuits or electric shock
hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this
enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no
user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this
enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment,
do not plug telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or hot component. If this surface is
contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to
cool before touching.
This symbol indicates that the component exceeds the recommended weight for one
individual to handle safely.
6.44 kg
14.20 lb
WARNING: To reduce the risk of personal injury or damage to the equipment,
observe local occupational health and safety requirements and guidelines for manual
material handling.
These symbols, on power supplies or systems, indicate that the equipment is supplied
by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock, remove all power cords
to completely disconnect power from the system.
Server blade preparation
To service any internal server blade component, power down the server blade and remove it from the
enclosure.
Removal and replacement procedures 23
Power down the server blade
Before powering down the server blade for any upgrade or maintenance procedures, perform a backup
of critical server data and programs.
Depending on the Onboard Administrator configuration, use one of the following methods to power down
the server blade:
•
Use a virtual power button selection through iLO 2.
This method initiates a controlled remote shutdown of applications and the OS before the server
blade enter standby mode.
•
Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server blade enter
standby mode.
•
Press and hold the Power On/Standby button for more than 4 seconds to force the server blade to
enter standby mode.
This method forces the server blade to enter standby mode without properly exiting applications and
the OS. It provides an emergency shutdown method in the event of a hung application.
•
Execute one of the following commands using the Onboard Administrator CLI:
poweroff server all
or
poweroff server all force
The first command initiates a controlled shutdown of applications and the OS before the server blade
enter standby mode. The second form of the command forces the server blade to enter standby mode
without exiting applications and the OS. This is an emergency method to force a shutdown in the
event of a hung application.
•
Use the Onboard Administrator GUI to initiate a shutdown:
a. Select the Enclosure Information tab, then select the Overall checkbox in the Device Bays item.
b. Initiate a shutdown from the Virtual Power menu:
— Select Momentary Press to initiate a controlled shutdown of applications and the OS.
— Select Press and Hold to initiate an emergency shutdown of applications and the OS.
IMPORTANT: When the server blade are in standby mode, auxiliary power is still being
provided. To remove all power from the server blade, remove the server blade from the
enclosure.
After initiating a virtual power down command, be sure that the server blade go into standby mode by
observing that the system power LED is amber.
Remove the server blade
To remove the component:
1.
Identify the proper server blade.
2.
Power down the server blade (on page 24).
Removal and replacement procedures 24
3.
Remove the server blade.
4.
Place the server blade on a flat, level work surface.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
Access panel
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Lift the access panel latch and slide the access panel to the rear.
4.
Remove the access panel.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
To replace the component:
1.
Place the access panel on top of the server blade with the hood latch open. Allow the panel to
extend past the rear of the server blade approximately 0.8 cm (0.2 in).
2.
Engage the anchoring pin with the corresponding hole in the latch.
3.
Push down on the hood latch. The access panel slides to a closed position.
Removal and replacement procedures 25
Hard drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade
or the enclosure unless all hard drive and device bays are populated with either a component
or a blank.
Remove the component as indicated.
To replace the blank, slide the blank into the bay until it locks into place.
Hard drive
To remove the component:
1.
Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations ("SAS and
SATA hard drive LED combinations" on page 56).
2.
Back up all server data on the hard drive.
Removal and replacement procedures 26
3.
Remove the hard drive.
To replace the component:
1.
Prepare the hard drive.
Removal and replacement procedures 27
2.
Install the hard drive.
FBDIMM
CAUTION: Use only HP FBDIMMs. FBDIMMs from other sources may adversely affect data
integrity.
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove the FBDIMM.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 28
Hard drive backplane
Some models of this server blade do not include a hard drive backplane.
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
CAUTION: Remove all hard drives and hard drive blanks before removing the hard drive
backplane.
6.
Remove the hard drive backplane. Use the backplane retainer to disengage the hard drive
backplane from the connector.
Removal and replacement procedures 29
To replace the component:
1.
Install the hard drive backplane. Press down on the hard drive backplane retainer to seat the board.
2.
Install the hard drives ("Hard drive" on page 26).
3.
Install the hard drive blanks ("Hard drive blank" on page 26).
4.
Install the access panel ("Access panel" on page 25).
5.
Install the server blade.
Hard drive backplane retainer
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
CAUTION: Remove all hard drives and hard drive blanks before removing the hard drive
backplane.
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
Removal and replacement procedures 30
7.
Remove the hard drive backplane retainer.
To replace the component:
1.
Install the hard drive backplane retainer.
2.
Install the hard drive backplane ("Hard drive backplane" on page 29).
3.
Install the hard drives ("Hard drive" on page 26).
4.
Install the hard drive blanks ("Hard drive blank" on page 26).
5.
Install the access panel ("Access panel" on page 25).
6.
Install the server blade.
Front panel/hard drive cage assembly
To remove the component:
1.
Power down the server blade (on page 24).
Removal and replacement procedures 31
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly.
To replace the component, reverse the removal procedure.
Mezzanine card
Optional mezzanine cards enable network connectivity and provide Fibre Channel support. For
mezzanine card locations, see the system board components (on page 57).
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
Removal and replacement procedures 32
4.
Remove the mezzanine card.
To replace the component:
1.
Install the mezzanine card. Press down on the connector to seat the card.
2.
Install the access panel ("Access panel" on page 25).
3.
Install the server blade.
HP Smart Array E200i Controller cache module
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
Removal and replacement procedures 33
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the Smart Array E200i Controller cache module.
To replace the component, reverse the removal procedure.
HP Smart Array E200i Controller battery pack
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the Smart Array E200i Controller cache module ("HP Smart Array E200i Controller cache
module" on page 33).
Removal and replacement procedures 34
8.
Remove the Smart Array E200i Controller battery pack.
To replace the component, reverse the removal procedure.
Server blade handle
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on
page 31).
Removal and replacement procedures 35
8.
Remove the server blade handle.
To replace the component, reverse the removal procedure.
Release button
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on
page 31).
Removal and replacement procedures 36
8.
Remove the release button.
To replace the component, reverse the removal procedure.
Heatsink
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on
page 31).
Removal and replacement procedures 37
8.
Remove the heatsink.
To replace the component:
1.
Clean the old thermal grease from the processor with the alcohol swab. Allow the alcohol to
evaporate before continuing.
2.
Remove the thermal interface protective cover from the heatsink.
CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an
"X" pattern).
Removal and replacement procedures 38
3.
Install the heatsink.
4.
Install the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on page
31).
5.
Install the hard drive backplane ("Hard drive backplane" on page 29).
6.
Install the hard drives ("Hard drive" on page 26).
7.
Install the hard drive blanks ("Hard drive blank" on page 26).
8.
Install the access panel ("Access panel" on page 25).
9.
Install the server blade.
Processor
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent possible server malfunction, do not mix processors of different speeds or
cache sizes. Refer to the label on the processor heatsink for a description of the processor.
CAUTION: To prevent possible server blade overheating, always populate processor socket 2
with a processor and a heatsink or a processor socket cover and a heatsink blank.
IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty, the
server blade does not power up.
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
Removal and replacement procedures 39
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on
page 31).
8.
Remove the heatsink ("Heatsink" on page 37).
9.
Open the processor retaining latch and the processor socket retaining bracket.
10.
Using your fingers, remove the failed processor.
To replace the component:
IMPORTANT: Be sure the processor remains inside the processor installation tool.
Removal and replacement procedures 40
1.
If the processor has separated from the installation tool, carefully re-insert the processor in the tool.
2.
Align the processor installation tool with the socket and install the spare processor.
CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides
on the processor and socket to properly align the processor with the socket. Refer to the server
blade hood label for specific instructions.
Removal and replacement procedures 41
3.
Press down firmly until the processor installation tool clicks and separates from the processor, and
then remove the processor installation tool.
4.
Close the processor retaining latch and the processor socket retaining bracket.
5.
Clean the old thermal grease from the heatsink with the alcohol swab. Allow the alcohol to
evaporate before continuing.
Removal and replacement procedures 42
6.
Apply all the grease to the top of the processor in one of the following patterns to ensure even
distribution:
CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an
"X" pattern).
7.
Install the heatsink.
8.
Install the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on page
31).
9.
Install the hard drive backplane ("Hard drive backplane" on page 29).
10.
Install the hard drive blanks ("Hard drive blank" on page 26).
11.
Install the hard drives ("Hard drive" on page 26).
12.
Install the access panel ("Access panel" on page 25).
13.
Install the server blade.
Removal and replacement procedures 43
System board
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on
page 31).
8.
Remove all FBDIMMs ("FBDIMM" on page 28).
9.
Remove any mezzanine cards ("Mezzanine card" on page 32).
10.
Remove the heatsink ("Heatsink" on page 37).
11.
Open the processor retaining latch and the processor socket retaining bracket.
CAUTION: To avoid damage to the processor:
• Handle the processor only by the edges.
• Do not touch the bottom of the processor, especially the contact area.
Removal and replacement procedures 44
12.
Using your fingers, remove the processor from the failed system board.
CAUTION: To avoid damage to the system board:
• Do not touch the processor socket contacts.
• Always install the processor socket cover after removing the processor from the socket.
• Do not tilt or slide the processor when lowering the processor into the socket.
13.
Remove the system board assembly.
To replace the system board:
Removal and replacement procedures 45
1.
Install the spare system board.
2.
Prepare the processor socket on the spare system board:
a. Open the processor retaining latch and the processor socket retaining bracket.
Removal and replacement procedures 46
b. Remove the processor socket protective cover.
3.
Install the processor socket cover onto the processor socket of the failed system board.
4.
Install the processor on the spare system board.
CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides
on the processor and socket to properly align the processor with the socket. Refer to the server
blade hood label for specific instructions.
CAUTION: Always install the processor parallel to the system board to avoid damage to the
pins.
Removal and replacement procedures 47
5.
Close the processor retaining latch and the processor socket retaining bracket.
6.
Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab.
Allow the alcohol to evaporate before continuing.
7.
Apply all the grease to the top of the processor in one of the following patterns to ensure even
distribution:
8.
Install the heatsink ("Heatsink" on page 37).
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
9.
Install all components removed from the failed system board.
10.
Install the hard drives ("Hard drive" on page 26).
11.
Install the hard drive blanks ("Hard drive blank" on page 26).
12.
Install the access panel ("Access panel" on page 25).
13.
Power up the server blade.
Removal and replacement procedures 48
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the F9 key to access RBSU.
2.
Select the System Options menu.
3.
Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
4.
Press the Enter key to clear the warning.
5.
Enter the serial number and press the Enter key.
6.
Select Product ID.
7.
Enter the product ID and press the Enter key.
8.
Press the Esc key to close the menu.
9.
Press the Esc key to exit RBSU.
10.
Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
System battery
If the server blade no longer automatically displays the correct date and time, you may need to replace
the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
• Replace only with the spare designated for this product.
To remove the component:
1.
Power down the server blade (on page 24).
2.
Remove the server blade (on page 24).
3.
Remove the access panel ("Access panel" on page 25).
4.
Remove all hard drives ("Hard drive" on page 26).
5.
Remove all hard drive blanks ("Hard drive blank" on page 26).
6.
Remove the hard drive backplane ("Hard drive backplane" on page 29).
7.
Remove the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on
page 31).
Removal and replacement procedures 49
8.
Remove the system board.
9.
Identify the battery location ("System board components" on page 57).
10.
Remove the battery.
IMPORTANT: Replacing the system board battery resets the system ROM to its default
configuration. After replacing the battery, reconfigure the system through RBSU.
To replace the component, reverse the removal procedure.
Removal and replacement procedures 50
Diagnostic tools
Troubleshooting resources
The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common problems and
comprehensive courses of action for fault isolation and identification, error message interpretation, issue
resolution, and software maintenance on ProLiant servers and server blades. This guide includes problemspecific flowcharts to help you navigate complex troubleshooting processes. To view the guide, select a
language:
•
English (http://www.hp.com/support/ProLiant_TSG_en)
•
French (http://www.hp.com/support/ProLiant_TSG_fr)
•
Italian (http://www.hp.com/support/ProLiant_TSG_it)
•
Spanish (http://www.hp.com/support/ProLiant_TSG_sp)
•
German (http://www.hp.com/support/ProLiant_TSG_gr)
•
Dutch (http://www.hp.com/support/ProLiant_TSG_nl)
•
Japanese (http://www.hp.com/support/ProLiant_TSG_jp)
The HP BladeSystem c-Class Enclosure Troubleshooting Guide provides procedures and solutions for
troubleshooting HP BladeSystem c-Class enclosures. This guide explains how to use the Insight Display to
troubleshoot enclosures, and it includes a flowchart to help you navigate the troubleshooting process. To
view the guide, see the HP website (http://www.hp.com/support/BladeSystem_Enclosure_TSG_en).
HP Insight Diagnostics
HP Insight Diagnostics is a proactive server blade management tool, available in both offline and online
versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify
server blade installations, troubleshoot problems, and perform repair validation.
HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the
OS is not running. To run this utility, launch the SmartStart CD.
HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and
other related data needed for effective server blade management. Available in Microsoft® Windows®
and Linux versions, the utility helps to ensure proper system operation.
For more information or to download the utility, refer to the HP website
(http://www.hp.com/servers/diags).
HP Insight Diagnostics survey functionality
HP Insight Diagnostics (on page 51) provides survey functionality that gathers critical hardware and
software information on ProLiant server blades.
Diagnostic tools 51
This functionality supports operating systems that may not be supported by the server blade. For operating
systems supported by the server blade, see the HP website (http://www.hp.com/go/supportos).
If a significant change occurs between data-gathering intervals, the survey function marks the previous
information and overwrites the survey data files to reflect the latest changes in the configuration.
Survey functionality is installed with every SmartStart-assisted HP Insight Diagnostics installation, or it can
be installed through the HP PSP.
NOTE: The current version of SmartStart provides the memory spare part numbers for the
server blade. To download the latest version, see the HP website
(http://www.hp.com/support).
Integrated Management Log
The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each
event with 1-minute granularity.
You can view recorded events in the IML in several ways, including the following:
•
From within HP SIM ("HP Systems Insight Manager" on page 52)
•
From within Survey Utility
•
From within operating system-specific IML viewers
o
For NetWare: IML Viewer
o
For Windows®: IML Viewer
o
For Linux: IML Viewer Application
•
From within the iLO 2 user interface
•
From within HP Insight Diagnostics (on page 51)
For more information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack.
Array Diagnostic Utility
The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage
controllers and disk drives. This report provides vital information to assist in identifying faults or conditions
that may require attention. ADU can be accessed from the SmartStart CD or downloaded from the HP
website (http://www.hp.com).
HP Systems Insight Manager
HP SIM is a web-based application that allows system administrators to accomplish normal administrative
tasks from any remote location, using a web browser. HP SIM provides device management capabilities
that consolidate and integrate management data from HP and third-party devices.
IMPORTANT: You must install and use HP SIM to benefit from the Pre-Failure Warranty for
processors, SAS and SATA hard drives, and memory modules.
For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack or
the HP SIM website (http://www.hp.com/go/hpsim).
Diagnostic tools 52
HP Instant Support Enterprise Edition
ISEE is a proactive remote monitoring and diagnostic tool to help manage your systems and devices, a
feature of HP support. ISEE provides continuous hardware event monitoring and automated notification to
identify and prevent potential critical problems. Through remote diagnostic scripts and vital system
configuration information collected about your systems, ISEE enables fast restoration of your systems.
Install ISEE on your systems to help mitigate risk and prevent potential critical problems.
For more information on ISEE, refer to the HP website
(http://www.hp.com/hps/hardware/hw_enterprise.html).
To download HP ISEE, visit the HP website (http://www.hp.com/hps/hardware/hw_downloads.html).
For installation information, refer to the HP ISEE Client Installation and Upgrade Guide
(ftp://ftp.hp.com/pub/services/hardware/info/isee_client.pdf).
Web-Based Enterprise Service
WEBES enables administrators to manage hardware events proactively, either locally or online. The
service provides real-time multiple event analysis, crash analysis, and notification, locally through SMTP
and remotely through ISEE for OpenVMS, Tru64, and Microsoft® Windows® operating system binary
error logs.
For more information, refer to the HP website (http://h18000.www1.hp.com/support/svctools/).
Open Services Event Manager
OSEM is a standalone tool that performs real-time reactive and proactive service event filtering, analysis,
and notification. The tool gathers event data from SNMP traps or information provided over an HTTP
interface and notifies an administrator or HP through SMTP and ISEE.
For more information, refer to the HP website (http://h18000.www1.hp.com/support/svctools/).
Diagnostic tools 53
Server component identification
Front panel components
Item
Description
1
Hard drive bay 1
2
Power On/Standby button
3
SUV connector*
4
Hard drive bay 2
5
Server blade handle
6
Release button
7
Serial label pull tab
* The SUV connector and the HP c-Class Blade SUV cable are for some server blade configuration and diagnostic
procedures.
Server component identification 54
Front panel LEDs
Item
Description
Status
1
UID LED
Blue = Identified
Blue flashing = Active remote management
Off = No active remote management
2
Health LED
Green = Normal
Flashing = Booting
Amber = Degraded condition
Red = Critical condition
3
NIC 1 LED*
Green = Network linked
Green flashing = Network activity
Off = No link or activity
4
NIC 2 LED*
Green = Network linked
Green flashing = Network activity
Off = No link or activity
5
System power LED
Green = On
Amber = Standby (auxiliary power available)
Off = Off
* Actual NIC numbers depend on several factors, including the operating system installed on the server blade.
Server component identification 55
SAS and SATA hard drive LEDs
Item
Description
1
Fault/UID LED (amber/blue)
2
Online LED (green)
SAS and SATA hard drive LED combinations
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or flashing Alternating amber
and blue
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been selected by a
management application.
On, off, or flashing Steadily blue
The drive is operating normally, and it has been selected by a
management application.
On
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
On
Off
The drive is online, but it is not active currently.
Flashing regularly
(1 Hz)
Amber, flashing
regularly (1 Hz)
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
Replace the drive as soon as possible.
The drive is part of an array that is undergoing capacity
expansion or stripe migration, but a predictive failure alert has
been received for this drive. To minimize the risk of data loss, do
not replace the drive until the expansion or migration is
complete.
Flashing regularly
(1 Hz)
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, erasing, or it is part of an array that is
undergoing capacity expansion or stripe migration.
Server component identification 56
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
Flashing irregularly Amber, flashing
regularly (1 Hz)
The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.
Flashing irregularly Off
The drive is active, and it is operating normally.
Off
Steadily amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.
Off
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
Off
The drive is offline, a spare, or not configured as part of an
array.
System board components
Item
Description
1
System board thumbscrew
2
Processor socket 2
3
Processor socket 1 (populated)
4
Hard drive backplane connector
5
FBDIMMs (8)
6
Embedded NICs (2)
7
Mezzanine connector 1 [Type I mezzanine only (shown)]
8
Battery
9
Mezzanine connector 2 [Type I (shown) or Type II mezzanine]
10
System maintenance switch (SW2)
11
System board thumbscrew
Server component identification 57
Item
Description
12
Enclosure connector
The symbols
correspond to the symbols located on the interconnect bays. For more information, see the
HP ProLiant BL460c Server Blade Installation Instructions that ship with the server blade.
Mezzanine connector definitions
Item
PCIe
Mezzanine connector 1
x4, Type I mezzanine card only
Mezzanine connector 2
x8, Type 1 or II mezzanine card
A PCIe x4 mezzanine connector supports x8 cards at up to x4 speeds. A PCIe x8 mezzanine connector supports x16
cards at up to x8 speeds.
FBDIMM slot numbering
FBDIMM slots
Memory bank
Memory branch
1 and 3
A
0
5 and 7
B
1
2 and 4
C
0
6 and 8
D
1
System maintenance switch
Position
Function
Default
1*
iLO 2 security override
Off
2
Configuration lock
Off
3
Reserved
Off
4
Reserved
Off
Server component identification 58
Position
Function
Default
5*
Password disabled
Off
6*
Reset configuration
Off
7
Reserved
Off
8
Reserved
Off
*To access redundant ROM, set S1, S5, and S6 to ON.
Hard drive backplane components
Some models of this server blade do not include a hard drive backplane.
Item
Description
1
Hard drive backplane thumbscrews (5)
2
Smart Array E200i Controller cache module
3
Internal USB connector
Server component identification 59
HP c-Class Blade SUV Cable
Item
Connector
Description
1
Server blade
For connecting to the SUV connector on the
server blade front panel
2
Video
For connecting a video monitor
3
USB
For connecting up to two USB devices
4
Serial
For trained personnel to connect a null modem
serial cable and perform advanced diagnostic
procedures
Server component identification 60
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 60°C (-40°F to 140°F)
Storage
-20°C to 60°C (-4°F to 140°F)
Maximum wet bulb temperature
30°C (86°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Shipping
10% to 90%
Storage
10% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70
Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server blade specifications
Specification
Value
Height
5.56 cm (2.19 in)
Depth
50.95 cm (20.06 in)
Width
18.16 cm (7.15 in)
Weight (maximum)
6.44 kg (14.20 lb)
Weight (no drives installed)
5.82 kg (12.82 lb)
Specifications
61
Acronyms and abbreviations
ADU
Array Diagnostics Utility
BBWC
battery-backed write cache
CSR
Customer Self Repair
ESD
electrostatic discharge
FBDIMM
fully buffered DIMM
FC
Fibre Channel
HBA
host bus adapter
I/O
input/output
iLO 2
Integrated Lights-Out 2
IML
Integrated Management Log
LED
light-emitting diode
NIC
network interface controller
Acronyms and abbreviations
62
PCI
peripheral component interface
PCIe
peripheral component interconnect express
RBSU
ROM-Based Setup Utility
ROM
read-only memory
SAS
serial attached SCSI
SATA
serial ATA
SFF
small form-factor
SIM
Systems Insight Manager
SUV
serial, USB, video
UID
unit identification
UPS
uninterruptible power system
USB
universal serial bus
Acronyms and abbreviations
63
Index
A
H
access panel 25
ADU (Array Diagnostic Utility) 52
Array Diagnostic Utility (ADU) 52
hard drive backplane 29, 59
hard drive backplane components 59
hard drive backplane connector 57, 59
hard drive backplane retainer 30
hard drive backplane thumbscrews 59
hard drive bays 54
hard drive blanks 26
hard drive LEDs 56
hard drives 26, 56
hard drives, determining status of 56
heatsink 37
heatsink blank 37
HP c-Class Blade SUV Cable 54, 60
HP Insight Diagnostics 22, 51
B
backplane, hard drive 29, 59
battery 49, 57
battery-backed write cache battery pack 34
buttons 54
C
cache module 33
cautions 22
component identification 54, 56
components 54
connectors 54
CSR (customer self repair) 5
customer self repair (CSR) 5
I
D
illustrated parts catalog 16
IML (Integrated Management Log) 52
Insight Diagnostics 22, 51
Integrated Management Log (IML) 52
internal USB connector 59
diagnostic tools 51
diagnostics utility 51
L
E
electrostatic discharge 22
enclosure connector 57
F
FBDIMM slot locations 57, 58
FBDIMMs 28, 57, 58
features 54
Fibre Channel mezzanine 32
front panel buttons 54
front panel components 54
front panel LEDs 55
front panel/hard drive cage assembly 31
LED, health 55, 56
LED, power button 55
LED, system power 55
LEDs, hard drive 56
LEDs, NIC 55
LEDs, unit identification (UID) 55
M
management tools 51
memory 28, 58
mezzanine board connectors 57
mezzanine boards 32
mezzanine connectors 57, 58
N
NIC (network interface card) 57
Index 64
P
Power On/Standby button 54
powering down 24
preparation procedures 23
processor socket 57
processors 39, 57
R
release button 36, 54
removing the access panel 25
removing the server blade 24
required tools 22
S
safety considerations 22
safety information 22
SAS drives 26, 56
SAS hard drive LEDs 56
SATA hard drive 26, 56
SATA hard drive LEDs 56
serial connector 60
serial label pull tab 54
server blade handle 35, 54
Smart Array E200i Controller components 33, 34
specifications, server blade 61
static electricity 22
SUV connector 54, 60
system battery 49
system board 44, 57
system board thumbscrews 57
system maintenance switch 57, 58
T
tools 22, 51
Torx screwdriver 22
troubleshooting 51
U
USB connectors 59, 60
utilities 51
V
video connector 60
video connector cabling 60
W
warnings 22
Index 65