PN5212/PN5320/PN7212/PN7320
Power Over the NET™
Power Distribution Units
ALTUSEN Power Over the NET™ products are Power Distribution Units that offer outlet level control combined with
remote access to give IT administrators the ability to power control devices attached to the unit from practically any
location via a TCP/IP connection. With support for power status measurement, PDUs enable administrators to
monitor the current, voltage and power consumption of their IT equipment, either at the PDU or outlet level,
minimizing the power cost of running their equipment; and ensuring high levels of system availability for server
rooms of all sizes.
The ALTUSEN PDU is highly suitable for server rooms or data centers with high-density server deployments. It
features a space-saving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a
more efficient use of server room space, and the elimination of the usual cable clutter. With NEMA or IEC outlet
support and with amperage capacity (20A or 30A for NEMA; 16A or 32A for IEC) , the PDU delivers plenty of power
to the rack, which means you can safely connect a larger number of IT devices than you could with ordinary power
units.
A measuring feature, coupled with a threshold alarm, keeps you informed of the operating status of all your
attached equipment. Warning messages regarding triggered alarms can be sent via an SMTP server or SMS via the
unit's Digital Output port. PDUs also provide sensor ports for temperature and humidity monitoring and threshold
alarm message notification. IT administrators are able to easily and conveniently monitor and power control
connected devices – remotely if necessary – by means of a browser-based UI, thereby minimizing maintenance costs
and ensuring 24/7 reliability for their server room operations.
ALTUSEN Power Distribution Units can be daisy-chained to manage even more devices, so your server room
management can expand in step with your company's growth. In a daisy-chained installation, administrators can
remotely monitor and control the power status of a server that has a dual power supply from a single portal, by
connecting its power cords to the outlets of separate level units (so they can receive power from separate sources).
For ease of management, when PDUs are deployed in conjunction with other ALTUSEN products*, administrators
can access them all from the same user interface.
When a PDU is integrated in a CC (Control Center Over the NET™) management software installation, the power
outlet of an IT device can be associated with its KVM port and displayed on the same CC web page. This allows IT
administrators to completely control an IT device from a single user interface. In addition, to provide the highest
possible system integration, the Intelligent PDU offers an API to support third-party management software.
*KVM Over the NET™
PN5212
Amp
20 A
16 A
Inlet
NEMA L5-20P
IEC60309
Outlet
12
Rack Space
0U
LAN Port
V
Daisy-chain
V
Switching Capability
Per Outlet
Metering Capability
PDU Level
Thresholds & Alarms
V
Environment Monitoring
Digital Output Port
Modem Support
PN5320
30 A
32 A
NEMA L5-30P IEC 60309
20
0U
V
V
Per Outlet
PDU Level
V
PN7212
20 A
16 A
NEMA L5-20P IEC60309
12
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
PN7320
30 A
32 A
NEMA L5-30P IEC60309
20
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
Early Warning
Notification
The PDU permits server room administrators to set custom thresholds for
current, voltage, power consumption, humidity, and temperature. When
levels exceed the user defined thresholds, designated recipients can receive
alarm notifications via SMTP email, SNMP traps, or SMS sender (connected to
the Digital Output port). An audio alarm can also sound and lights with blink
at the local site. Necessary steps can be taken to avoid equipment damage
due to such things as circuit overload – reducing mean time to recovery and
minimizing loss.
Environment Monitoring
The PDU supports external, environment sensors that allow administrators to
monitor temperature and humidity remotely. IT administrators can set
environment thresholds to identify critical value and take preventive actions
before a system failure occurs – thereby helping to obtain the highest degree
of availability for all mission-critical equipment.
Management
FEATURES
Power Distribution
• Maximum Amps/Outlet:
NEMA 20A / 12 outlets (PN5212/PN7212); 30A/ 20 outlets (PN52320/PN7320)
IEC 16A / 12 outlets (PN5212/PN7212); 32A/ 20 outlets (PN5320/PN7320)
• Space saving 0U rack mount design
• IEC or NEMA outlet models
• Daisy chain up to 15 additional stations for up to 192 (PN5212 / PN7212) or 320 (PN5320 /
PN7320) outlets
• 2 x 7 segment front panel LED shows Station and Outlet ID
• Overcurrent protection and recovery for the PDU
• Remote users can monitor outlet status via web pages on their browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets. The user interface is still
accessible even when an overload condition trips the devices' circuit breaker
Remote Access
• Remote power control via TCP/IP and a built in 10/100 Ethernet port
• Out of Band operation via modem access*
• Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, ARP, NTP, DNS, Telnet,
10Base-T/100Base-TX, auto sense, Ping
• IPv6 support
Operation
• Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets and outlet
groups
• Outlet group support at the PDU and Daisy-chain levels – the same action can be performed on
a specified group of outlets at the same time
• Supports redundant power management via daisy chaining and outlet groups
• On/Off scheduling for individual outlets and outlet groups. Power management tasks can be
scheduled on a daily, weekly, monthly, or user-specified times basis
• Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and delay time for each outlet to
allow equipment to be turned on in the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Mozilla, Firefox, Safari, Opera, Netscape)
• Telnet and SSH access for text menu configuration and outlet level switching / monitoring
• Local console access support
• Java GUI AP program provided for non-browser connectivity
• RTC support to keep the timer running during times of no power.
• Up to 64 user accounts - up to 32 concurrent logins
• Power status measurement at PDU and outlet* levels
• LED indicators for current; voltage; power dissipation; temperature; and humidity at the PDU
and outlet* levels
• Current; voltage; power dissipation; and energy consumption displayed in a browsed-based UI
for monitoring at the outlet*, group, PDU, and daisy-chain levels
• Environment monitoring* – supports external temperature/temperature & humidity sensors for
rack temperature and humidity monitoring
• Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold
level setting
• Alert threshold notification for selected events (On, Off, Recycle, Failure, etc.), via audio alarm
and blinking LEDs (locally), SMTP, SNMP trap notification, and digital output*
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis.
• Windows-based Log Server; event logging, and syslog support
• Integration with ALTUSEN CC2000 Management software and KVM devices
• API for 3rd party software centralized control integration
• Upgradeable firmware – daisy chained stations receive the upgrade via the daisy chain bus
• Multi-language support: English, German, Traditional Chinese, Smplified Chinese, Japanese,
Korean, Russian
Security
•
•
•
•
Three-level password security
IP/MAC filtering
Secure 128-bit SSL encryption
Remote authentication support: RADIUS, TACACS+, LDAP, LDAPS and Active Directory
Centralized
Management
*Feature supported by PN7212/PN7320 only
Benefits
Remote Monitoring
Outlet Switching
With PDU/Outlet level metering, IT administrators can easily monitor the
current, voltage, and power consumption status of all connected IT equipment
via a browser-based UI. With the addition of temperature and humidity sensors,
even the status of the rack environment can be monitored from just about
anywhere in the world.
By simply clicking a button on the browser-based UI, administrators can power
control the connected devices with ease. There is no longer any need to move
around the server room turning equipment on and off. Outlet level remote
switching ensures that the server room operates smoothly.
ALTUSEN Product
Integration*
Redundant Power
Management
Combining with ALTUSEN's CC (Control Center Over the NET™)
management software gives IT administrators the advantages of centralized
control over the entire Power Over the NET™ installation, as well as all other
Over the NET™ products from a single user interface. By associating the KVM
port, serial port and power outlet of an IT device, all the ports can be
presented on the same web page for convenient access and management. In
addition, a free API is included with the PDU that provides the ability to
integrate the unit into your existing IT applications and tools.
The ALTUSEN PDU can be integrated with multiple ALTUSEN devices to
provide a single interface point – the switch’s interface – allowing IT
administrators to control servers or serial devices at the same time as they
control their power management. For KVM switches that support the Power
Association function, a KVM port can be associated with a power outlet. If
the connected server has a dual power supply the KVM port can be
associated with two outlet ports and the operation of both power supplies
can be synchronized.
The ALTUSEN PDU supports daisy-chaining and outlet groups to provide
redundant power management. Equipment with dual power supplies can be
assigned to outlet groups for convenient control. Since up to 15 additional
units can be daisy chained from the master unit, IT administrators can
connect a server’s power cords to different units - each of which is connected
to a separate power source - for failsafe operation. Management efficiency is
also increased, since the power status of both outlets can be monitored and
controlled from the same portal.
Specification
Function
PN5212
PN5320
PN7212
PN7320
12
20
12
20
192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Chain) 320 (via Daisy Chain)
1 x NEMA L5-20P
1 x NEMA L5-30P
1 x NEMA L5-20P
1 x NEMA L5-30P
Power NEMA
Inlets
IEC
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
3
x
NEMA
5-20R
3
x NEMA 5-20R
NEMA
12 x NEMA 5-15R
12 x NEMA 5-15R
17 x NEMA 5-15R
17 x NEMA 5-15R
Power
Outlets
3 x IEC320 C19
3 x IEC320 C19
IEC
12 x IEC320 C13
12 x IEC320 C13
17 x IEC320 C13
17 x IEC320 C13
Connectors PON In / Console
1 x RJ-45 (F)
PON Out
1 x RJ-45 (F)
Modem
N/A
1 x RJ-45 (F)
LAN
1 x RJ-45 (F)
Environment Sensor
N/A
2 x RJ-11 (F)
Digital Output
N/A
1 x Terminal Block
ID
1 x 2-digit 7-segment
Station
1 x Green
Outlet
N/A
1 x Green
Readout
1 x 3-digit 7-segment
Current
1 x Green
LEDs
Voltage
1 x Green
Power
1 x Green
Sensor 1
N/A
1 x Green
Sensor 2
N/A
1 x Green
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
16A
24A
16A
24A
I/P Rating
(Total Input)
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
16A
32A
16A
32A
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
NEMA
1920W
2880W
1920W
2880W
Load Capacity
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
IEC
3680W
7360W
3680W
7360W
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
12A
16A (x3) / 12A (x17)
12A
16A (x3) / 12A (x17)
Per Port
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
10A
16A (x3) / 10A (x17)
10A
16A (x3) / 10A (x17)
O/P Rating
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
15A
23A
15A
23A
Total
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
15A
31A
15A
31A
NEMA
120V; 50/60Hz; 16W 120V; 50/60Hz; 22W 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W
Power Consumption
IEC
230V; 50/60Hz; 18W 230V; 50/60Hz; 26W 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W
Operating Temp.
0-50℃
Environment
Storage Temp.
-20 - 60℃
Humidity
0-80% RH Non-condensing
Housing
Metal
Physical
Weight
4.49 kg
5.68 kg
4.49 kg
5.68 kg
Properties
Dimensions
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
(L x W x H)
cm
cm
cm
cm
Power
Outlets
Direct
Max
Inlet/Outlet
Model
No.
Inlet
Inlet Typ
1
NEMA L5(120V)
PN5212
1
IEC 6030
(230V)
1
NEMA L5(120V)
PN5320
1
IEC 6030
(230V)
Optional Eq
EA1140
• Temperature Sen
EA1240
• Temperature & H
Sensor
ATEN In
3F., No.12
Phone: 88
*KVM Over the NET™
p1
p2
p3
p4
p5
p6
© Co
ATEN
Printe
PN5212/PN5320/PN7212/PN7320
Power Over the NET™
Power Distribution Units
ALTUSEN Power Over the NET™ products are Power Distribution Units that offer outlet level control combined with
remote access to give IT administrators the ability to power control devices attached to the unit from practically any
location via a TCP/IP connection. With support for power status measurement, PDUs enable administrators to
monitor the current, voltage and power consumption of their IT equipment, either at the PDU or outlet level,
minimizing the power cost of running their equipment; and ensuring high levels of system availability for server
rooms of all sizes.
The ALTUSEN PDU is highly suitable for server rooms or data centers with high-density server deployments. It
features a space-saving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a
more efficient use of server room space, and the elimination of the usual cable clutter. With NEMA or IEC outlet
support and with amperage capacity (20A or 30A for NEMA; 16A or 32A for IEC) , the PDU delivers plenty of power
to the rack, which means you can safely connect a larger number of IT devices than you could with ordinary power
units.
A measuring feature, coupled with a threshold alarm, keeps you informed of the operating status of all your
attached equipment. Warning messages regarding triggered alarms can be sent via an SMTP server or SMS via the
unit's Digital Output port. PDUs also provide sensor ports for temperature and humidity monitoring and threshold
alarm message notification. IT administrators are able to easily and conveniently monitor and power control
connected devices – remotely if necessary – by means of a browser-based UI, thereby minimizing maintenance costs
and ensuring 24/7 reliability for their server room operations.
ALTUSEN Power Distribution Units can be daisy-chained to manage even more devices, so your server room
management can expand in step with your company's growth. In a daisy-chained installation, administrators can
remotely monitor and control the power status of a server that has a dual power supply from a single portal, by
connecting its power cords to the outlets of separate level units (so they can receive power from separate sources).
For ease of management, when PDUs are deployed in conjunction with other ALTUSEN products*, administrators
can access them all from the same user interface.
When a PDU is integrated in a CC (Control Center Over the NET™) management software installation, the power
outlet of an IT device can be associated with its KVM port and displayed on the same CC web page. This allows IT
administrators to completely control an IT device from a single user interface. In addition, to provide the highest
possible system integration, the Intelligent PDU offers an API to support third-party management software.
*KVM Over the NET™
PN5212
Amp
20 A
16 A
Inlet
NEMA L5-20P
IEC60309
Outlet
12
Rack Space
0U
LAN Port
V
Daisy-chain
V
Switching Capability
Per Outlet
Metering Capability
PDU Level
Thresholds & Alarms
V
Environment Monitoring
Digital Output Port
Modem Support
PN5320
30 A
32 A
NEMA L5-30P IEC 60309
20
0U
V
V
Per Outlet
PDU Level
V
PN7212
20 A
16 A
NEMA L5-20P IEC60309
12
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
PN7320
30 A
32 A
NEMA L5-30P IEC60309
20
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
Early Warning
Notification
The PDU permits server room administrators to set custom thresholds for
current, voltage, power consumption, humidity, and temperature. When
levels exceed the user defined thresholds, designated recipients can receive
alarm notifications via SMTP email, SNMP traps, or SMS sender (connected to
the Digital Output port). An audio alarm can also sound and lights with blink
at the local site. Necessary steps can be taken to avoid equipment damage
due to such things as circuit overload – reducing mean time to recovery and
minimizing loss.
Environment Monitoring
The PDU supports external, environment sensors that allow administrators to
monitor temperature and humidity remotely. IT administrators can set
environment thresholds to identify critical value and take preventive actions
before a system failure occurs – thereby helping to obtain the highest degree
of availability for all mission-critical equipment.
Management
FEATURES
Power Distribution
• Maximum Amps/Outlet:
NEMA 20A / 12 outlets (PN5212/PN7212); 30A/ 20 outlets (PN52320/PN7320)
IEC 16A / 12 outlets (PN5212/PN7212); 32A/ 20 outlets (PN5320/PN7320)
• Space saving 0U rack mount design
• IEC or NEMA outlet models
• Daisy chain up to 15 additional stations for up to 192 (PN5212 / PN7212) or 320 (PN5320 /
PN7320) outlets
• 2 x 7 segment front panel LED shows Station and Outlet ID
• Overcurrent protection and recovery for the PDU
• Remote users can monitor outlet status via web pages on their browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets. The user interface is still
accessible even when an overload condition trips the devices' circuit breaker
Remote Access
• Remote power control via TCP/IP and a built in 10/100 Ethernet port
• Out of Band operation via modem access*
• Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, ARP, NTP, DNS, Telnet,
10Base-T/100Base-TX, auto sense, Ping
• IPv6 support
Operation
• Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets and outlet
groups
• Outlet group support at the PDU and Daisy-chain levels – the same action can be performed on
a specified group of outlets at the same time
• Supports redundant power management via daisy chaining and outlet groups
• On/Off scheduling for individual outlets and outlet groups. Power management tasks can be
scheduled on a daily, weekly, monthly, or user-specified times basis
• Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and delay time for each outlet to
allow equipment to be turned on in the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Mozilla, Firefox, Safari, Opera, Netscape)
• Telnet and SSH access for text menu configuration and outlet level switching / monitoring
• Local console access support
• Java GUI AP program provided for non-browser connectivity
• RTC support to keep the timer running during times of no power.
• Up to 64 user accounts - up to 32 concurrent logins
• Power status measurement at PDU and outlet* levels
• LED indicators for current; voltage; power dissipation; temperature; and humidity at the PDU
and outlet* levels
• Current; voltage; power dissipation; and energy consumption displayed in a browsed-based UI
for monitoring at the outlet*, group, PDU, and daisy-chain levels
• Environment monitoring* – supports external temperature/temperature & humidity sensors for
rack temperature and humidity monitoring
• Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold
level setting
• Alert threshold notification for selected events (On, Off, Recycle, Failure, etc.), via audio alarm
and blinking LEDs (locally), SMTP, SNMP trap notification, and digital output*
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis.
• Windows-based Log Server; event logging, and syslog support
• Integration with ALTUSEN CC2000 Management software and KVM devices
• API for 3rd party software centralized control integration
• Upgradeable firmware – daisy chained stations receive the upgrade via the daisy chain bus
• Multi-language support: English, German, Traditional Chinese, Smplified Chinese, Japanese,
Korean, Russian
Security
•
•
•
•
Three-level password security
IP/MAC filtering
Secure 128-bit SSL encryption
Remote authentication support: RADIUS, TACACS+, LDAP, LDAPS and Active Directory
Centralized
Management
*Feature supported by PN7212/PN7320 only
Benefits
Remote Monitoring
Outlet Switching
With PDU/Outlet level metering, IT administrators can easily monitor the
current, voltage, and power consumption status of all connected IT equipment
via a browser-based UI. With the addition of temperature and humidity sensors,
even the status of the rack environment can be monitored from just about
anywhere in the world.
By simply clicking a button on the browser-based UI, administrators can power
control the connected devices with ease. There is no longer any need to move
around the server room turning equipment on and off. Outlet level remote
switching ensures that the server room operates smoothly.
ALTUSEN Product
Integration*
Redundant Power
Management
Combining with ALTUSEN's CC (Control Center Over the NET™)
management software gives IT administrators the advantages of centralized
control over the entire Power Over the NET™ installation, as well as all other
Over the NET™ products from a single user interface. By associating the KVM
port, serial port and power outlet of an IT device, all the ports can be
presented on the same web page for convenient access and management. In
addition, a free API is included with the PDU that provides the ability to
integrate the unit into your existing IT applications and tools.
The ALTUSEN PDU can be integrated with multiple ALTUSEN devices to
provide a single interface point – the switch’s interface – allowing IT
administrators to control servers or serial devices at the same time as they
control their power management. For KVM switches that support the Power
Association function, a KVM port can be associated with a power outlet. If
the connected server has a dual power supply the KVM port can be
associated with two outlet ports and the operation of both power supplies
can be synchronized.
The ALTUSEN PDU supports daisy-chaining and outlet groups to provide
redundant power management. Equipment with dual power supplies can be
assigned to outlet groups for convenient control. Since up to 15 additional
units can be daisy chained from the master unit, IT administrators can
connect a server’s power cords to different units - each of which is connected
to a separate power source - for failsafe operation. Management efficiency is
also increased, since the power status of both outlets can be monitored and
controlled from the same portal.
Specification
Function
PN5212
PN5320
PN7212
PN7320
12
20
12
20
192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Chain) 320 (via Daisy Chain)
1 x NEMA L5-20P
1 x NEMA L5-30P
1 x NEMA L5-20P
1 x NEMA L5-30P
Power NEMA
Inlets
IEC
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
3
x
NEMA
5-20R
3
x NEMA 5-20R
NEMA
12 x NEMA 5-15R
12 x NEMA 5-15R
17 x NEMA 5-15R
17 x NEMA 5-15R
Power
Outlets
3 x IEC320 C19
3 x IEC320 C19
IEC
12 x IEC320 C13
12 x IEC320 C13
17 x IEC320 C13
17 x IEC320 C13
Connectors PON In / Console
1 x RJ-45 (F)
PON Out
1 x RJ-45 (F)
Modem
N/A
1 x RJ-45 (F)
LAN
1 x RJ-45 (F)
Environment Sensor
N/A
2 x RJ-11 (F)
Digital Output
N/A
1 x Terminal Block
ID
1 x 2-digit 7-segment
Station
1 x Green
Outlet
N/A
1 x Green
Readout
1 x 3-digit 7-segment
Current
1 x Green
LEDs
Voltage
1 x Green
Power
1 x Green
Sensor 1
N/A
1 x Green
Sensor 2
N/A
1 x Green
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
16A
24A
16A
24A
I/P Rating
(Total Input)
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
16A
32A
16A
32A
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
NEMA
1920W
2880W
1920W
2880W
Load Capacity
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
IEC
3680W
7360W
3680W
7360W
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
12A
16A (x3) / 12A (x17)
12A
16A (x3) / 12A (x17)
Per Port
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
10A
16A (x3) / 10A (x17)
10A
16A (x3) / 10A (x17)
O/P Rating
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
15A
23A
15A
23A
Total
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
15A
31A
15A
31A
NEMA
120V; 50/60Hz; 16W 120V; 50/60Hz; 22W 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W
Power Consumption
IEC
230V; 50/60Hz; 18W 230V; 50/60Hz; 26W 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W
Operating Temp.
0-50℃
Environment
Storage Temp.
-20 - 60℃
Humidity
0-80% RH Non-condensing
Housing
Metal
Physical
Weight
4.49 kg
5.68 kg
4.49 kg
5.68 kg
Properties
Dimensions
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
(L x W x H)
cm
cm
cm
cm
Power
Outlets
Direct
Max
Inlet/Outlet
Model
No.
Inlet
Inlet Typ
1
NEMA L5(120V)
PN5212
1
IEC 6030
(230V)
1
NEMA L5(120V)
PN5320
1
IEC 6030
(230V)
Optional Eq
EA1140
• Temperature Sen
EA1240
• Temperature & H
Sensor
ATEN In
3F., No.12
Phone: 88
*KVM Over the NET™
p1
p2
p3
p4
p5
p6
© Co
ATEN
Printe
PN5212/PN5320/PN7212/PN7320
Power Over the NET™
Power Distribution Units
ALTUSEN Power Over the NET™ products are Power Distribution Units that offer outlet level control combined with
remote access to give IT administrators the ability to power control devices attached to the unit from practically any
location via a TCP/IP connection. With support for power status measurement, PDUs enable administrators to
monitor the current, voltage and power consumption of their IT equipment, either at the PDU or outlet level,
minimizing the power cost of running their equipment; and ensuring high levels of system availability for server
rooms of all sizes.
The ALTUSEN PDU is highly suitable for server rooms or data centers with high-density server deployments. It
features a space-saving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a
more efficient use of server room space, and the elimination of the usual cable clutter. With NEMA or IEC outlet
support and with amperage capacity (20A or 30A for NEMA; 16A or 32A for IEC) , the PDU delivers plenty of power
to the rack, which means you can safely connect a larger number of IT devices than you could with ordinary power
units.
A measuring feature, coupled with a threshold alarm, keeps you informed of the operating status of all your
attached equipment. Warning messages regarding triggered alarms can be sent via an SMTP server or SMS via the
unit's Digital Output port. PDUs also provide sensor ports for temperature and humidity monitoring and threshold
alarm message notification. IT administrators are able to easily and conveniently monitor and power control
connected devices – remotely if necessary – by means of a browser-based UI, thereby minimizing maintenance costs
and ensuring 24/7 reliability for their server room operations.
ALTUSEN Power Distribution Units can be daisy-chained to manage even more devices, so your server room
management can expand in step with your company's growth. In a daisy-chained installation, administrators can
remotely monitor and control the power status of a server that has a dual power supply from a single portal, by
connecting its power cords to the outlets of separate level units (so they can receive power from separate sources).
For ease of management, when PDUs are deployed in conjunction with other ALTUSEN products*, administrators
can access them all from the same user interface.
When a PDU is integrated in a CC (Control Center Over the NET™) management software installation, the power
outlet of an IT device can be associated with its KVM port and displayed on the same CC web page. This allows IT
administrators to completely control an IT device from a single user interface. In addition, to provide the highest
possible system integration, the Intelligent PDU offers an API to support third-party management software.
*KVM Over the NET™
PN5212
Amp
20 A
16 A
Inlet
NEMA L5-20P
IEC60309
Outlet
12
Rack Space
0U
LAN Port
V
Daisy-chain
V
Switching Capability
Per Outlet
Metering Capability
PDU Level
Thresholds & Alarms
V
Environment Monitoring
Digital Output Port
Modem Support
PN5320
30 A
32 A
NEMA L5-30P IEC 60309
20
0U
V
V
Per Outlet
PDU Level
V
PN7212
20 A
16 A
NEMA L5-20P IEC60309
12
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
PN7320
30 A
32 A
NEMA L5-30P IEC60309
20
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
Early Warning
Notification
The PDU permits server room administrators to set custom thresholds for
current, voltage, power consumption, humidity, and temperature. When
levels exceed the user defined thresholds, designated recipients can receive
alarm notifications via SMTP email, SNMP traps, or SMS sender (connected to
the Digital Output port). An audio alarm can also sound and lights with blink
at the local site. Necessary steps can be taken to avoid equipment damage
due to such things as circuit overload – reducing mean time to recovery and
minimizing loss.
Environment Monitoring
The PDU supports external, environment sensors that allow administrators to
monitor temperature and humidity remotely. IT administrators can set
environment thresholds to identify critical value and take preventive actions
before a system failure occurs – thereby helping to obtain the highest degree
of availability for all mission-critical equipment.
Management
FEATURES
Power Distribution
• Maximum Amps/Outlet:
NEMA 20A / 12 outlets (PN5212/PN7212); 30A/ 20 outlets (PN52320/PN7320)
IEC 16A / 12 outlets (PN5212/PN7212); 32A/ 20 outlets (PN5320/PN7320)
• Space saving 0U rack mount design
• IEC or NEMA outlet models
• Daisy chain up to 15 additional stations for up to 192 (PN5212 / PN7212) or 320 (PN5320 /
PN7320) outlets
• 2 x 7 segment front panel LED shows Station and Outlet ID
• Overcurrent protection and recovery for the PDU
• Remote users can monitor outlet status via web pages on their browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets. The user interface is still
accessible even when an overload condition trips the devices' circuit breaker
Remote Access
• Remote power control via TCP/IP and a built in 10/100 Ethernet port
• Out of Band operation via modem access*
• Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, ARP, NTP, DNS, Telnet,
10Base-T/100Base-TX, auto sense, Ping
• IPv6 support
Operation
• Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets and outlet
groups
• Outlet group support at the PDU and Daisy-chain levels – the same action can be performed on
a specified group of outlets at the same time
• Supports redundant power management via daisy chaining and outlet groups
• On/Off scheduling for individual outlets and outlet groups. Power management tasks can be
scheduled on a daily, weekly, monthly, or user-specified times basis
• Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and delay time for each outlet to
allow equipment to be turned on in the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Mozilla, Firefox, Safari, Opera, Netscape)
• Telnet and SSH access for text menu configuration and outlet level switching / monitoring
• Local console access support
• Java GUI AP program provided for non-browser connectivity
• RTC support to keep the timer running during times of no power.
• Up to 64 user accounts - up to 32 concurrent logins
• Power status measurement at PDU and outlet* levels
• LED indicators for current; voltage; power dissipation; temperature; and humidity at the PDU
and outlet* levels
• Current; voltage; power dissipation; and energy consumption displayed in a browsed-based UI
for monitoring at the outlet*, group, PDU, and daisy-chain levels
• Environment monitoring* – supports external temperature/temperature & humidity sensors for
rack temperature and humidity monitoring
• Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold
level setting
• Alert threshold notification for selected events (On, Off, Recycle, Failure, etc.), via audio alarm
and blinking LEDs (locally), SMTP, SNMP trap notification, and digital output*
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis.
• Windows-based Log Server; event logging, and syslog support
• Integration with ALTUSEN CC2000 Management software and KVM devices
• API for 3rd party software centralized control integration
• Upgradeable firmware – daisy chained stations receive the upgrade via the daisy chain bus
• Multi-language support: English, German, Traditional Chinese, Smplified Chinese, Japanese,
Korean, Russian
Security
•
•
•
•
Three-level password security
IP/MAC filtering
Secure 128-bit SSL encryption
Remote authentication support: RADIUS, TACACS+, LDAP, LDAPS and Active Directory
Centralized
Management
*Feature supported by PN7212/PN7320 only
Benefits
Remote Monitoring
Outlet Switching
With PDU/Outlet level metering, IT administrators can easily monitor the
current, voltage, and power consumption status of all connected IT equipment
via a browser-based UI. With the addition of temperature and humidity sensors,
even the status of the rack environment can be monitored from just about
anywhere in the world.
By simply clicking a button on the browser-based UI, administrators can power
control the connected devices with ease. There is no longer any need to move
around the server room turning equipment on and off. Outlet level remote
switching ensures that the server room operates smoothly.
ALTUSEN Product
Integration*
Redundant Power
Management
Combining with ALTUSEN's CC (Control Center Over the NET™)
management software gives IT administrators the advantages of centralized
control over the entire Power Over the NET™ installation, as well as all other
Over the NET™ products from a single user interface. By associating the KVM
port, serial port and power outlet of an IT device, all the ports can be
presented on the same web page for convenient access and management. In
addition, a free API is included with the PDU that provides the ability to
integrate the unit into your existing IT applications and tools.
The ALTUSEN PDU can be integrated with multiple ALTUSEN devices to
provide a single interface point – the switch’s interface – allowing IT
administrators to control servers or serial devices at the same time as they
control their power management. For KVM switches that support the Power
Association function, a KVM port can be associated with a power outlet. If
the connected server has a dual power supply the KVM port can be
associated with two outlet ports and the operation of both power supplies
can be synchronized.
The ALTUSEN PDU supports daisy-chaining and outlet groups to provide
redundant power management. Equipment with dual power supplies can be
assigned to outlet groups for convenient control. Since up to 15 additional
units can be daisy chained from the master unit, IT administrators can
connect a server’s power cords to different units - each of which is connected
to a separate power source - for failsafe operation. Management efficiency is
also increased, since the power status of both outlets can be monitored and
controlled from the same portal.
Specification
Function
PN5212
PN5320
PN7212
PN7320
12
20
12
20
192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Chain) 320 (via Daisy Chain)
1 x NEMA L5-20P
1 x NEMA L5-30P
1 x NEMA L5-20P
1 x NEMA L5-30P
Power NEMA
Inlets
IEC
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
3
x
NEMA
5-20R
3
x NEMA 5-20R
NEMA
12 x NEMA 5-15R
12 x NEMA 5-15R
17 x NEMA 5-15R
17 x NEMA 5-15R
Power
Outlets
3 x IEC320 C19
3 x IEC320 C19
IEC
12 x IEC320 C13
12 x IEC320 C13
17 x IEC320 C13
17 x IEC320 C13
Connectors PON In / Console
1 x RJ-45 (F)
PON Out
1 x RJ-45 (F)
Modem
N/A
1 x RJ-45 (F)
LAN
1 x RJ-45 (F)
Environment Sensor
N/A
2 x RJ-11 (F)
Digital Output
N/A
1 x Terminal Block
ID
1 x 2-digit 7-segment
Station
1 x Green
Outlet
N/A
1 x Green
Readout
1 x 3-digit 7-segment
Current
1 x Green
LEDs
Voltage
1 x Green
Power
1 x Green
Sensor 1
N/A
1 x Green
Sensor 2
N/A
1 x Green
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
16A
24A
16A
24A
I/P Rating
(Total Input)
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
16A
32A
16A
32A
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
NEMA
1920W
2880W
1920W
2880W
Load Capacity
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
IEC
3680W
7360W
3680W
7360W
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
12A
16A (x3) / 12A (x17)
12A
16A (x3) / 12A (x17)
Per Port
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
10A
16A (x3) / 10A (x17)
10A
16A (x3) / 10A (x17)
O/P Rating
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
15A
23A
15A
23A
Total
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
15A
31A
15A
31A
NEMA
120V; 50/60Hz; 16W 120V; 50/60Hz; 22W 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W
Power Consumption
IEC
230V; 50/60Hz; 18W 230V; 50/60Hz; 26W 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W
Operating Temp.
0-50℃
Environment
Storage Temp.
-20 - 60℃
Humidity
0-80% RH Non-condensing
Housing
Metal
Physical
Weight
4.49 kg
5.68 kg
4.49 kg
5.68 kg
Properties
Dimensions
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
(L x W x H)
cm
cm
cm
cm
Power
Outlets
Direct
Max
Inlet/Outlet
Model
No.
Inlet
Inlet Typ
1
NEMA L5(120V)
PN5212
1
IEC 6030
(230V)
1
NEMA L5(120V)
PN5320
1
IEC 6030
(230V)
Optional Eq
EA1140
• Temperature Sen
EA1240
• Temperature & H
Sensor
ATEN In
3F., No.12
Phone: 88
*KVM Over the NET™
p1
p2
p3
p4
p5
p6
© Co
ATEN
Printe
Early Warning
Notification
The PDU permits server room administrators to set custom thresholds for
current, voltage, power consumption, humidity, and temperature. When
levels exceed the user defined thresholds, designated recipients can receive
alarm notifications via SMTP email, SNMP traps, or SMS sender (connected to
the Digital Output port). An audio alarm can also sound and lights with blink
at the local site. Necessary steps can be taken to avoid equipment damage
due to such things as circuit overload – reducing mean time to recovery and
minimizing loss.
Environment Monitoring
The PDU supports external, environment sensors that allow administrators to
monitor temperature and humidity remotely. IT administrators can set
environment thresholds to identify critical value and take preventive actions
before a system failure occurs – thereby helping to obtain the highest degree
of availability for all mission-critical equipment.
Centralized
Management
Combining with ALTUSEN's CC (Control Center Over the NET™)
management software gives IT administrators the advantages of centralized
control over the entire Power Over the NET™ installation, as well as all other
Over the NET™ products from a single user interface. By associating the KVM
port, serial port and power outlet of an IT device, all the ports can be
presented on the same web page for convenient access and management. In
addition, a free API is included with the PDU that provides the ability to
integrate the unit into your existing IT applications and tools.
ALTUSEN Product
Integration*
The ALTUSEN PDU can be integrated with multiple ALTUSEN devices to
provide a single interface point – the switch’s interface – allowing IT
administrators to control servers or serial devices at the same time as they
control their power management. For KVM switches that support the Power
Association function, a KVM port can be associated with a power outlet. If
the connected server has a dual power supply the KVM port can be
associated with two outlet ports and the operation of both power supplies
can be synchronized.
Redundant Power
Management
The ALTUSEN PDU supports daisy-chaining and outlet groups to provide
redundant power management. Equipment with dual power supplies can be
assigned to outlet groups for convenient control. Since up to 15 additional
units can be daisy chained from the master unit, IT administrators can
connect a server’s power cords to different units - each of which is connected
to a separate power source - for failsafe operation. Management efficiency is
also increased, since the power status of both outlets can be monitored and
controlled from the same portal.
*KVM Over the NET™
p4
Specification
Function
PN5212
PN5320
Direct
Max
PN7212
PN7320
12
20
12
20
Power
Outlets
192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Chain) 320 (via Daisy Chain)
1 x NEMA L5-20P
1 x NEMA L5-30P
1 x NEMA L5-20P
1 x NEMA L5-30P
Power NEMA
Inlets
IEC
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
3 x NEMA 5-20R
3 x NEMA 5-20R
NEMA
12 x NEMA 5-15R
12
x
NEMA
5-15R
17 x NEMA 5-15R
17 x NEMA 5-15R
Power
Outlets
3
x
IEC320
C19
3 x IEC320 C19
IEC
12 x IEC320 C13
12 x IEC320 C13
17 x IEC320 C13
17 x IEC320 C13
Connectors PON In / Console
1 x RJ-45 (F)
PON Out
1 x RJ-45 (F)
Modem
N/A
1 x RJ-45 (F)
LAN
1 x RJ-45 (F)
Environment Sensor
N/A
2 x RJ-11 (F)
Digital Output
N/A
1 x Terminal Block
ID
1 x 2-digit 7-segment
Station
1 x Green
Outlet
N/A
1 x Green
Readout
1 x 3-digit 7-segment
Current
1 x Green
LEDs
Voltage
1 x Green
Power
1 x Green
Sensor 1
N/A
1 x Green
Sensor 2
N/A
1 x Green
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
16A
24A
16A
24A
I/P Rating
(Total Input)
200-240V;
50/60Hz;
200-240V;
50/60Hz;
200-240V;
50/60Hz;
200-240V;
50/60Hz;
IEC
16A
32A
16A
32A
120V; 50/60Hz;
120V; 50/60Hz;
120V; 50/60Hz;
120V; 50/60Hz;
NEMA
1920W
2880W
1920W
2880W
Load Capacity
230V;
50/60Hz;
230V;
50/60Hz;
230V;
50/60Hz;
230V;
50/60Hz;
IEC
3680W
7360W
3680W
7360W
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
12A
16A (x3) / 12A (x17)
12A
16A (x3) / 12A (x17)
Per Port
200-240V;
50/60Hz;
200-240V;
50/60Hz;
200-240V;
50/60Hz;
200-240V;
50/60Hz;
IEC
10A
16A (x3) / 10A (x17)
10A
16A (x3) / 10A (x17)
O/P Rating
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
15A
23A
15A
23A
Total
200-240V;
50/60Hz;
200-240V;
50/60Hz;
200-240V;
50/60Hz;
200-240V;
50/60Hz;
IEC
15A
31A
15A
31A
NEMA
120V; 50/60Hz; 16W 120V; 50/60Hz; 22W 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W
Power Consumption
IEC
230V; 50/60Hz; 18W 230V; 50/60Hz; 26W 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W
Operating Temp.
0-50℃
Environment
Storage Temp.
-20 - 60℃
Humidity
0-80% RH Non-condensing
Housing
Metal
Physical
Weight
4.49 kg
5.68 kg
4.49 kg
5.68 kg
Properties
Dimensions
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
(L x W x H)
cm
cm
cm
cm
p5
PN5212/PN5320/PN7212/PN7320
Power Over the NET™
Power Distribution Units
ALTUSEN Power Over the NET™ products are Power Distribution Units that offer outlet level control combined with
remote access to give IT administrators the ability to power control devices attached to the unit from practically any
location via a TCP/IP connection. With support for power status measurement, PDUs enable administrators to
monitor the current, voltage and power consumption of their IT equipment, either at the PDU or outlet level,
minimizing the power cost of running their equipment; and ensuring high levels of system availability for server
rooms of all sizes.
The ALTUSEN PDU is highly suitable for server rooms or data centers with high-density server deployments. It
features a space-saving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a
more efficient use of server room space, and the elimination of the usual cable clutter. With NEMA or IEC outlet
support and with amperage capacity (20A or 30A for NEMA; 16A or 32A for IEC) , the PDU delivers plenty of power
to the rack, which means you can safely connect a larger number of IT devices than you could with ordinary power
units.
A measuring feature, coupled with a threshold alarm, keeps you informed of the operating status of all your
attached equipment. Warning messages regarding triggered alarms can be sent via an SMTP server or SMS via the
unit's Digital Output port. PDUs also provide sensor ports for temperature and humidity monitoring and threshold
alarm message notification. IT administrators are able to easily and conveniently monitor and power control
connected devices – remotely if necessary – by means of a browser-based UI, thereby minimizing maintenance costs
and ensuring 24/7 reliability for their server room operations.
ALTUSEN Power Distribution Units can be daisy-chained to manage even more devices, so your server room
management can expand in step with your company's growth. In a daisy-chained installation, administrators can
remotely monitor and control the power status of a server that has a dual power supply from a single portal, by
connecting its power cords to the outlets of separate level units (so they can receive power from separate sources).
For ease of management, when PDUs are deployed in conjunction with other ALTUSEN products*, administrators
can access them all from the same user interface.
When a PDU is integrated in a CC (Control Center Over the NET™) management software installation, the power
outlet of an IT device can be associated with its KVM port and displayed on the same CC web page. This allows IT
administrators to completely control an IT device from a single user interface. In addition, to provide the highest
possible system integration, the Intelligent PDU offers an API to support third-party management software.
*KVM Over the NET™
PN5212
Amp
20 A
16 A
Inlet
NEMA L5-20P
IEC60309
Outlet
12
Rack Space
0U
LAN Port
V
Daisy-chain
V
Switching Capability
Per Outlet
Metering Capability
PDU Level
Thresholds & Alarms
V
Environment Monitoring
Digital Output Port
Modem Support
PN5320
30 A
32 A
NEMA L5-30P IEC 60309
20
0U
V
V
Per Outlet
PDU Level
V
PN7212
20 A
16 A
NEMA L5-20P IEC60309
12
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
PN7320
30 A
32 A
NEMA L5-30P IEC60309
20
0U
V
V
Per Outlet
Outlet & PDU Level
V
V
V
V
Management
FEATURES
Power Distribution
• Maximum Amps/Outlet:
NEMA 20A / 12 outlets (PN5212/PN7212); 30A/ 20 outlets (PN52320/PN7320)
IEC 16A / 12 outlets (PN5212/PN7212); 32A/ 20 outlets (PN5320/PN7320)
• Space saving 0U rack mount design
• IEC or NEMA outlet models
• Daisy chain up to 15 additional stations for up to 192 (PN5212 / PN7212) or 320 (PN5320 /
PN7320) outlets
• 2 x 7 segment front panel LED shows Station and Outlet ID
• Overcurrent protection and recovery for the PDU
• Remote users can monitor outlet status via web pages on their browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets. The user interface is still
accessible even when an overload condition trips the devices' circuit breaker
Remote Access
• Remote power control via TCP/IP and a built in 10/100 Ethernet port
• Out of Band operation via modem access*
• Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, ARP, NTP, DNS, Telnet,
10Base-T/100Base-TX, auto sense, Ping
• IPv6 support
Operation
• Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets and outlet
groups
• Outlet group support at the PDU and Daisy-chain levels – the same action can be performed on
a specified group of outlets at the same time
• Supports redundant power management via daisy chaining and outlet groups
• On/Off scheduling for individual outlets and outlet groups. Power management tasks can be
scheduled on a daily, weekly, monthly, or user-specified times basis
• Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and delay time for each outlet to
allow equipment to be turned on in the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Mozilla, Firefox, Safari, Opera, Netscape)
• Telnet and SSH access for text menu configuration and outlet level switching / monitoring
• Local console access support
• Java GUI AP program provided for non-browser connectivity
• RTC support to keep the timer running during times of no power.
• Up to 64 user accounts - up to 32 concurrent logins
• Power status measurement at PDU and outlet* levels
• LED indicators for current; voltage; power dissipation; temperature; and humidity at the PDU
and outlet* levels
• Current; voltage; power dissipation; and energy consumption displayed in a browsed-based UI
for monitoring at the outlet*, group, PDU, and daisy-chain levels
• Environment monitoring* – supports external temperature/temperature & humidity sensors for
rack temperature and humidity monitoring
• Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold
level setting
• Alert threshold notification for selected events (On, Off, Recycle, Failure, etc.), via audio alarm
and blinking LEDs (locally), SMTP, SNMP trap notification, and digital output*
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis.
• Windows-based Log Server; event logging, and syslog support
• Integration with ALTUSEN CC2000 Management software and KVM devices
• API for 3rd party software centralized control integration
• Upgradeable firmware – daisy chained stations receive the upgrade via the daisy chain bus
• Multi-language support: English, German, Traditional Chinese, Smplified Chinese, Japanese,
Korean, Russian
Security
•
•
•
•
Three-level password security
IP/MAC filtering
Secure 128-bit SSL encryption
Remote authentication support: RADIUS, TACACS+, LDAP, LDAPS and Active Directory
Early Warning
Notification
Environment Monitoring
Centralized
Management
*Feature supported by PN7212/PN7320 only
Benefits
Remote Monitoring
Outlet Switching
With PDU/Outlet level metering, IT administrators can easily monitor the
current, voltage, and power consumption status of all connected IT equipment
via a browser-based UI. With the addition of temperature and humidity sensors,
even the status of the rack environment can be monitored from just about
anywhere in the world.
By simply clicking a button on the browser-based UI, administrators can power
control the connected devices with ease. There is no longer any need to move
around the server room turning equipment on and off. Outlet level remote
switching ensures that the server room operates smoothly.
ALTUSEN Product
Integration*
Redundant Power
Management
The PDU permits server room administrators to set custom thresholds for
current, voltage, power consumption, humidity, and temperature. When
levels exceed the user defined thresholds, designated recipients can receive
alarm notifications via SMTP email, SNMP traps, or SMS sender (connected to
the Digital Output port). An audio alarm can also sound and lights with blink
at the local site. Necessary steps can be taken to avoid equipment damage
due to such things as circuit overload – reducing mean time to recovery and
minimizing loss.
The PDU supports external, environment sensors that allow administrators to
monitor temperature and humidity remotely. IT administrators can set
environment thresholds to identify critical value and take preventive actions
before a system failure occurs – thereby helping to obtain the highest degree
of availability for all mission-critical equipment.
Combining with ALTUSEN's CC (Control Center Over the NET™)
management software gives IT administrators the advantages of centralized
control over the entire Power Over the NET™ installation, as well as all other
Over the NET™ products from a single user interface. By associating the KVM
port, serial port and power outlet of an IT device, all the ports can be
presented on the same web page for convenient access and management. In
addition, a free API is included with the PDU that provides the ability to
integrate the unit into your existing IT applications and tools.
The ALTUSEN PDU can be integrated with multiple ALTUSEN devices to
provide a single interface point – the switch’s interface – allowing IT
administrators to control servers or serial devices at the same time as they
control their power management. For KVM switches that support the Power
Association function, a KVM port can be associated with a power outlet. If
the connected server has a dual power supply the KVM port can be
associated with two outlet ports and the operation of both power supplies
can be synchronized.
The ALTUSEN PDU supports daisy-chaining and outlet groups to provide
redundant power management. Equipment with dual power supplies can be
assigned to outlet groups for convenient control. Since up to 15 additional
units can be daisy chained from the master unit, IT administrators can
connect a server’s power cords to different units - each of which is connected
to a separate power source - for failsafe operation. Management efficiency is
also increased, since the power status of both outlets can be monitored and
controlled from the same portal.
Internet/
LAN
Specification
Function
PN5212
PN5320
PN7212
PN7320
12
20
12
20
192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Chain) 320 (via Daisy Chain)
1 x NEMA L5-20P
1 x NEMA L5-30P
1 x NEMA L5-20P
1 x NEMA L5-30P
Power NEMA
Inlets
IEC
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
1 x IEC 60309
3
x
NEMA
5-20R
3
x NEMA 5-20R
NEMA
12 x NEMA 5-15R
12 x NEMA 5-15R
17 x NEMA 5-15R
17 x NEMA 5-15R
Power
Outlets
3 x IEC320 C19
3 x IEC320 C19
IEC
12 x IEC320 C13
12 x IEC320 C13
17 x IEC320 C13
17 x IEC320 C13
Connectors PON In / Console
1 x RJ-45 (F)
PON Out
1 x RJ-45 (F)
Modem
N/A
1 x RJ-45 (F)
LAN
1 x RJ-45 (F)
Environment Sensor
N/A
2 x RJ-11 (F)
Digital Output
N/A
1 x Terminal Block
ID
1 x 2-digit 7-segment
Station
1 x Green
Outlet
N/A
1 x Green
Readout
1 x 3-digit 7-segment
Current
1 x Green
LEDs
Voltage
1 x Green
Power
1 x Green
Sensor 1
N/A
1 x Green
Sensor 2
N/A
1 x Green
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
100-120V; 50/60Hz;
NEMA
16A
24A
16A
24A
I/P Rating
(Total Input)
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
16A
32A
16A
32A
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
120V;
50/60Hz;
NEMA
1920W
2880W
1920W
2880W
Load Capacity
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
230V; 50/60Hz;
IEC
3680W
7360W
3680W
7360W
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
12A
16A (x3) / 12A (x17)
12A
16A (x3) / 12A (x17)
Per Port
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
10A
16A (x3) / 10A (x17)
10A
16A (x3) / 10A (x17)
O/P Rating
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
100-120V;
50/60Hz;
NEMA
15A
23A
15A
23A
Total
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
200-240V; 50/60Hz;
IEC
15A
31A
15A
31A
NEMA
120V; 50/60Hz; 16W 120V; 50/60Hz; 22W 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W
Power Consumption
IEC
230V; 50/60Hz; 18W 230V; 50/60Hz; 26W 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W
Operating Temp.
0-50℃
Environment
Storage Temp.
-20 - 60℃
Humidity
0-80% RH Non-condensing
Housing
Metal
Physical
Weight
4.49 kg
5.68 kg
4.49 kg
5.68 kg
Properties
Dimensions
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
6.42 x 5.46 x 134
6.42 x 5.46 x 167.64
(L x W x H)
cm
cm
cm
cm
Power
Outlets
PN7320
Direct
Max
Up to 20 Servers/Devices
Up to 15 additional PDUs can be daisy-chained
Inlet/Outlet Chart
Model
No.
Inlet
Inlet Type
1
Inlet
Current
Outlet
20A
12
NEMA L5-20P
(120V)
PN5212
1
Outlet Type
Outlet
Current
16A
12
IEC 60309
(230V)
Outlet
20A
12
16A
1
12
30A
3
17
10A
1
16A
p2
p3
p4
16A
NEMA 5-20R
PN7320
IEC320 C19
12A
NEMA 5-15R
32A
IEC 60309
(230V)
10A
IEC320 C13
3
16A
IEC320 C19
Optional Equipment
EA1140
• Temperature Sensor
EA1240
• Temperature & Humidity
Sensor
Temperature Sensor
(EA1140)
Function
Connectors
Measurement Range
Power Consumption
Storage Temperature
Housing
Weight
Cable Length
Range
Accuracy
0 ~ 60 °C
+/- 1°C
Temperature & Humidity Sensor
(EA1240)
RJ-11
0 ~ 60 °C
+/- 1°C
12V, 60mW
-20 - 60°C
Plastic
0.07 kg
3 meter
15 ~ 95 % RH
+/- 5% RH
ATEN International Co., Ltd.
3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, Taiwan
Phone: 886-2-8692-6789 Fax: 886-2-8692-6767 www.aten.com E-mail: marketing@aten.com
*KVM Over the NET™
p1
10A
IEC320 C13
NEMA L5-30P
(120V)
IEC320 C13
Outlet
Current
12A
17
16A
3
Outlet Type
NEMA 5-15R
IEC 60309
(230V)
NEMA 5-20R
32A
Inlet
Current
12A
17
1
1
10A
3
NEMA L5-30P
(120V)
PN5320
PN7212
NEMA 5-15R
30A
Inlet Type
NEMA L5-20P
(120V)
IEC320 C13
17
1
Inlet
1
12A
NEMA 5-15R
IEC 60309
(230V)
Model
No.
p5
p6
© Copyright 2011 ATEN® International Co., Ltd.
ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners.
Printed 08/2011 V2.0
www.aten.com