CRESTRON
Contents
Slide Controller: SP-SC
Description
Functional Description
Physical Description
Specifications
Setup
SP-SC with SmartPresenter™
SP-SC with SmarTouch™ ST-CP
SP-SC with CNMSX
Programming
SmartPresenter™ SP-1
SmarTouch™ ST-CP
CNMSX
Problem Solving
Troubleshooting
Further Inquiries
Return and Warranty Policies
Merchandise Returns / Repair Service
CRESTRON Limited Warranty
Operations Guide - DOC. 5729
1
1
1
1
2
3
3
4
5
6
6
6
6
7
7
7
8
8
8
Contents • i
CRESTRON
Slide Controller: SP-SC
Description
Functional Description
The SP-SC is a slide controller that allows easy control of slide projectors from the
SmartPresenter, Smartouch ST-CP, and CNMSX systems.
Physical Description
The SP-SC is a small unit with a permanently attached 6 ft. (183 cm) projector cable.
The projector cable is equipped with an EBY, pickle type connector. A 3ft. (91 cm)
Serial Data Cable is supplied for connection to the SmartPresenter or the SmarTouch
ST-CP systems.
SP-SC: Top View
Operations Guide - DOC. 5729
Slide Controller: SP-SC • 1
CRESTRON
Specifications
Dimensions:
Length
Width
Height
4.850" (123.19 mm)
1.324" (33.63 mm)
1.052" (26.72 mm)
6.2 oz. (176 g)
Projector Cable:
Connector Type
Length
EBY, Five-pin, Pickle
6' (183 cm)
Serial Data Cable¹:
Connector Type
Length
3.5 mm, Straight, Stereo
3' (91.44 cm)
Weight:
Serial Data Cable²:
Crestron p/n CNSP-112
12v DC Power Supply*: Crestron p/n PW-1205
(USA and Canada)
Input 120V 60Hz 18W
Output 12vDC 0.5A
Software:
Crestron p/n PWI-1210
(International)
Input 230V 50Hz 110mA
Output 12V---1.0A 12VA
SIMPL™ Windows®
VisionTools Pro™
Crestron Database
Version 1.20.04 or later
Version 1.1.3 or later
Version 11.7.207 or later
¹ For SmartPresenter and SmarTouch ST-CP (supplied)
² Required for use with CNMSX (Sold separately)
* Required for use with SmarTouch ST-CP and CNMSX (sold separately)
Cable Length = 6'
(183 cm)
4.850"
(123.19 mm)
1.324"
(33.63 mm)
1.052"
(26.72 mm)
2 • Slide Controller: SP-SC
Operations Guide - DOC. 5729
CRESTRON
Setup
SP-SC with SmartPresenter™
Connect the 3.5 mm, Serial Data Cable (supplied) to the input port on the SP-SC.
Connect the other end of the cable to one of the outputs on the SP-1. The EBY, fivepin, pickle type connector should be plugged into the projector.
To assign a Q-Code for the Slide Controller, refer to the latest revision of the
SmartPresenter – Quick Guide (DOC. 5742).
NOTE: An external power supply is not necessary when using the SP-SC with the
SmartPresenter system.
Connect Serial Data Cable to SP-1
To Slide Projector
Serial Data Cable
Serial Data Cable
Operations Guide - DOC. 5729
Slide Controller: SP-SC • 3
CRESTRON
SP-SC with SmarTouch™ ST-CP
Connect the 3.5 mm, Serial Data Cable (supplied) to the input port on the SP-SC.
Connect the other end of the cable to one of the outputs on the ST-CP. The EBY,
five-pin, pickle type connector should be plugged into the projector.
To program the ST-CP for the Slide Controller, refer to the SmarTouch STS Wizard
included with VisionTools Pro™ or Crestron's SIMPL™ Windows® programming
software (v 1.20.04 or later) and the latest version of the Crestron Database (v
11.7.207).
NOTE: An external power supply must be used when using the SP-SC with the
SmarTouch ST-CP system. Refer to "Specifications" on page 2 for part number and
input/output voltage specifications.
Connect Serial Data Cable to ST-CP
Serial Data Cable
External
Power Supply
To Slide Projector
Serial Data Cable
4 • Slide Controller: SP-SC
Operations Guide - DOC. 5729
CRESTRON
SP-SC with CNMSX
The SP-SC can be used with a variety of Crestron systems, including the CNMSX.
When used with a CNMSX there are additional hardware requirements.
•
A specially designed Serial Data Cable is required (p/n CNSP-112).
•
An external power supply is required. Refer to "Specifications" on
page 2 for part number and input/output voltage specifications.
Connect the stereo plug of the CNSP-112 into the input port of the SP-SC. Connect
the Phoenix type connector to of the CNSP-112 to one of the Infrared – Serial output
ports on the CNMSX.
To program the CNMSX for the Slide Controller, refer to Crestron's SIMPL™
Windows® programming software (v 1.20.04 or later) and the latest version of the
Crestron Database (v 11.7.207).
NOTE: An external power supply must be used when using the SP-SC with the
CNMSX system. A CNSP-112 Serial Data Cable is also required.
Connect to CNMSX
Serial Data Cable
CNSP-112
External
Power Supply
To Slide Projector
S
G
Serial Data Cable
CNSP-112
Operations Guide - DOC. 5729
Slide Controller: SP-SC • 5
CRESTRON
Programming
SmartPresenter™ SP-1
The SmartPresenter is field programmable and does not require a PC. Refer to the
latest revision of the SmartPresenter – Quick Guide (DOC. 5742). SmartPresenter
software is available, however, it is only necessary for changing drivers, cloning
SP-1 machines, and updating firmware.
SmarTouch™ ST-CP
The SmarTouch systems are easily programmed using the SmarTouch STS Wizard.
In several easy steps a SmarTouch system can be programmed and up-loaded. The
STS Wizard is available in VisionTools Pro™ software.
SmarTouch systems may also be custom programmed using Crestron's easy-to-use
SIMPL™ Windows® and VisionTools Pro™ software.
CNMSX
The CNMSX is programmed using Crestron's easy-to-use SIMPL™ Windows®
software.
Example Program shown as Block Diagram
This example allows a touchpanel to control a slide projector via the IR-Device (SPSC). Feedback is provided to alert the touchpanel user that a button is, in fact, being
pressed. The IR Device represents the driver for the SP-SC. This SP-SC driver can
be located in the Crestron Database (version 11.7.207 or later), under Slide
Controllers.
6 • Slide Controller: SP-SC
Operations Guide - DOC. 5729
CRESTRON
Problem Solving
Troubleshooting
TROUBLE
SP-SC not
functioning.
POSSIBLE
CAUSE(S)
SmartPresenter
Q-Code incorrect
SmarTouch ST-CP
/CMMSX
Incorrect Driver
Selected
No 12v power supply
CORRECTIVE ACTION
Verify that the correct Q-Code for the
device has been assigned.
Select the correct driver from the
Crestron database.
12v power supply must be used
(see "Specifications" on page 2).
Further Inquiries
If after reviewing this Operations Guide, you cannot locate specific information or
have questions, please take advantage of Crestron's award winning technical support
team by calling:
•
In the US and Canada, call Crestron’s corporate headquarters at
1.888.CRESTRON [1.888.273.7876] or 1.201.767.3400.
•
In Europe, call Crestron International at +32.15.50.99.50.
•
In Asia, call Crestron Asia at +852.2341.2016.
•
In Latin America, call Crestron Latin America at +525.574.15.90.
For local support from exclusive Crestron factory trained personnel call:
Operations Guide - DOC. 5729
•
In Australia, call Soundcorp at +613.941.61066.
•
In New Zealand, call Amber Technologies at +649.410.8382.
Slide Controller: SP-SC • 7
CRESTRON
Return and Warranty Policies
Merchandise Returns / Repair Service
1.
2.
3.
No merchandise may be returned for credit, exchange, or service
without prior authorization from CRESTRON. To obtain warranty
service for CRESTRON products, contact the factory and request an
RMA (Return Merchandise Authorization) number. Enclose a note
specifying the nature of the problem, name and phone number of
contact person, RMA number, and return address.
Products may be returned for credit, exchange, or service with a
CRESTRON Return Merchandise Authorization (RMA) number.
Authorized returns must be shipped freight prepaid to CRESTRON,
Cresskill, N.J., or its authorized subsidiaries, with RMA number clearly
marked on the outside of all cartons. Shipments arriving freight collect
or without an RMA number shall be subject to refusal. CRESTRON
reserves the right in its sole and absolute discretion to charge a 15%
restocking fee, plus shipping costs, on any products returned with an
RMA.
Return freight charges following repair of items under warranty shall
be paid by CRESTRON, shipping by standard ground carrier. In the
event repairs are found to be non-warranty, return freight costs shall be
paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its Cresnet products, denoted by a
"CN" prefix model number, to be free from manufacturing defects in materials and
workmanship for a period of three (3) years from the date of shipment to purchaser.
Disk drives and any other moving or rotating mechanical parts are covered for a
period of one (1) year. CRESTRON warrants all its other products for a period of
one year from the defects mentioned above, excluding touchscreen display
components which are covered for 90 days. Incandescent lamps are completely
excluded from Crestron's Limited Warranty. CRESTRON shall, at its option, repair
or replace any product found defective without charge for parts or labor. Repaired or
replaced equipment and parts supplied under this warranty shall be covered only by
the unexpired portion of the warranty.
CRESTRON shall not be liable to honor warranty terms if the product has been used
in any application other than that for which it was intended, or if it has been
subjected to misuse, accidental damage, modification, or improper installation
procedures. Furthermore, this warranty does not cover any product that has had the
serial number altered, defaced, or removed.
This warranty shall be the sole and exclusive remedy to the purchaser. In no event
shall CRESTRON be liable for incidental or consequential damages of any kind
(property or economic damages inclusive) arising from the sale or use of this
equipment. CRESTRON makes no other warranties nor authorizes any other party to
offer any warranty, expressed or implied, including warranties of merchantability for
this product. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names, and trademarks are the sole property of their
respective owners. Windows is a registered trademark of Microsoft Corporation.
Windows95, Windows98 and WindowsNT are trademarks of Microsoft Corporation.
8 • Slide Controller: SP-SC
Operations Guide - DOC. 5729