GP-2400/2500/2600 Series

User Manual

(Pro-Designer Compatible)

Preface

Thank you for purchasing the Pro-face GP2400/2500/2600 Series programmable operator interface (hereafter referred to as the “GP unit”).

GP2400/2500/2600 Series units allow you to use the Ethernet, CF Card, and

Sound Output features without attaching separately sold expansion units.

Please read this manual carefully as it explains, step by step, how to use the GP correctly and safely.

Also, in this manual’s examples, the Mitsubishi MELSEC-AnA Series PLC is used whenever possible, connected in a one-to-one relationship with a GP.

<Note>

1) It is forbidden to copy the contents of this manual, in whole or in part, except for the user’s personal use, without the express permission of Digital Electronics Corporation of Japan.

2) The information provided in this manual is subject to change without notice.

3) This manual has been written with care and attention to detail; however, should you find any errors or omissions, please contact Digital and inform them of your findings.

4) Please be aware that Digital shall not be held liable by the user for any damages, losses, or third party claims arising from any uses of this product.

All Company/Manufacturer names used in this manual are the registered trademarks of those companies.

© 2002, Digital Electronics Corporation

GP-2400/2500/2600 Series User Manual 1

2

Preface

Table of Contents

Preface ........................................................................................................................ 1

Table of Contents ...................................................................................................... 2

Essential Safety Precautions ................................................................................... 4

General Safety Precautions .................................................................................... 8

GP2400/2500/2600 Series Models ........................................................................ 10

Package Contents ................................................................................................... 11

UL/c-UL (CSA) Application Notes .................................................................... 12

CE Marking Notes ............................................................................................... 13

Revisions .................................................................................................................. 13

Documentation Conventions ................................................................................. 14

CHAPTER 1 INTRODUCTION

1.1

System Design ............................................................................................... 1-1

1.2

Accessories .................................................................................................... 1-3

CHAPTER 2 SPECIFICATIONS

2.1

General Specifications ................................................................................. 2-1

2.1.1

Electrical ............................................................................................ 2-1

2.1.2

Environmental .................................................................................... 2-2

2.1.3

Structural ............................................................................................ 2-3

2.2

Functional Specifications ............................................................................ 2-4

2.2.1

Display ............................................................................................... 2-4

2.2.2

Memory .............................................................................................. 2-5

2.2.3

Clock .................................................................................................. 2-5

2.2.4

Interfaces ........................................................................................... 2-6

2.3

Interface Specifications ............................................................................... 2-7

2.3.1

Serial Interfaces (COM1) .................................................................. 2-7

2.3.2

Sound Output ..................................................................................... 2-9

2.4

Part Names and Functions ....................................................................... 2-10

2.5

Dimensions .................................................................................................. 2-12

2.5.1

GP-2400 Series External Dimensions ........................................... 2-12

2.5.2

GP-2500 Series External Dimensions ........................................... 2-12

2.5.3

GP-2600 Series External Dimensions ........................................... 2-13

2.5.4

Panel Cut Dimensions ..................................................................... 2-13

2.5.5

Installation Fasteners ....................................................................... 2-14

GP-2400/2500/2600 Series User Manual

Preface

CHAPTER 3 INSTALLATION AND WIRING

3.1

Installation .................................................................................................... 3-1

3.1.1

Installation Procedures ...................................................................... 3-1

3.2

Wiring Cautions ........................................................................................... 3-6

3.2.1

Connecting the Power Cord .............................................................. 3-6

3.2.2

Connecting the Power Supply ......................................................... 3-8

3.2.3

Grounding .......................................................................................... 3-9

3.2.4

I/O Signal Line Placement ................................................................ 3-9

3.3

Tool Connector ........................................................................................... 3-10

3.4 Ethernet Cable Connector ........................................................................ 3-10

3.5

CF Card Installation and Removal ......................................................... 3-11

3.5.1

CF Card Handling ............................................................................ 3-13

3.6

Sound Output ............................................................................................. 3-14

3.6.1

Connecting Speaker Lines .............................................................. 3-14

CHAPTER 4 SETTINGS

4.1

Types of Settings .......................................................................................... 4-1

4.1.1

Offline ................................................................................................ 4-3

4.1.2

System ................................................................................................ 4-5

CHAPTER 5 TROUBLESHOOTING

5.1

Troubleshooting Checklists ........................................................................ 5-1

5.1.1

No display .......................................................................................... 5-2

5.1.2

Connected devices cannot be used ................................................... 5-2

5.2

SELF TEST ................................................................................................... 5-3

5.2.1

SELF TEST item list ......................................................................... 5-3

5.2.2

SELF TEST - details ......................................................................... 5-4

CHAPTER 6 MAINTENANCE

6.1

Regular Cleaning ......................................................................................... 6-1

6.1.1

Cleaning the Display ......................................................................... 6-1

6.1.2

Installation Gasket Check/Replacement .......................................... 6-1

6.2

Periodic Check Points ................................................................................. 6-3

6.3

Replacing the Backlight .............................................................................. 6-4

GP-2400/2500/2600 Series User Manual 3

4

Preface

Essential Safety Precautions

This manual includes procedures that must be followed to operate the GP correctly and safely. Be sure to read this manual and any related materials thoroughly to understand the correct operation and functions of this unit.

Safety Icons

Throughout this manual the following icons are provided next to GP operation procedures requiring special attention, and provide essential safety information.

These icons indicate the following levels of danger:

Warning

Indicates situations where severe bodily injury, death or major equipment damage can occur.

Caution

Indicates situations where slight bodily injury or machine damage can occur.

WARNINGS

System Design

• Do not create GP touch panel switches that could possibly endanger the safety of equipment and personnel. Damage to the GP, its I/O unit(s), cable(s), and other related equipment can cause an output signal to remain continuously

ON or OFF and possibly cause a major accident. Therefore, design all monitoring circuits using limit switches, etc. to detect incorrect device movement. To prevent accidents related to incorrect signal output or operation, design all switches used to control vital machine operations so they are operated via a separate control system.

• Please design your system so that equipment will not malfunction due to a communication fault between the GP and its host controller. This is to prevent any possibility of bodily injury or material damage.

• Do not use the GP unit as a warning device for critical alarms that can cause serious operator injury, machine damage or production stoppage. Critical alarm indicators and their control/activator units must be designed using stand-alone hardware and/or mechanical interlocks.

• The GP is not appropriate for use with aircraft control devices, aerospace equipment, central trunk data transmission (communication) devices, nuclear power control devices, or medical life support equipment, due to these devices’ inherent requirements of extremely high levels of safety and reliability.

GP-2400/2500/2600 Series User Manual

Preface

WARNINGS

• Do not create switches used to control machine safety operations, such as an emergency stop switch, as a GP touch screen icon. Be sure to install these switches as separate hardware switches, otherwise severe bodily injury or equipment damage can occur.

• When using the GP with transportation vehicles (trains, cars and ships), disaster and crime prevention devices, various types of safety equipment, non-life support related medical devices, etc. redundant and/or failsafe system designs should be used to ensure the proper degree of reliability and safety.

Touch Panel

• After the GP’s backlight burns out, the touch panel is still active. If the operator fails to notice that the backlight is burned out and touches the panel, a potentially dangerous malfunction can occur.

If your GP’s backlight suddenly turns OFF, use the following steps to determine if the backlight is actually burned out.

1) When the backlight burnout feature is not set, and the screen has gone blank, your backlight is burned out.

2) When the backlight burnout feature is set, and the screen has gone blank, if touching the screen does not cause the backlight to tourn ON, your backlight is burned out.

It is recommended to use the feature that disables the device operation to prevent accidental machine misoperation when a backlight burnout is detected automatically.

Wiring

• To prevent electrical shock or equipment damage, unplug the GP unit’s power cord from the power supply prior to installing or wiring the GP.

• After completing any GP wiring work, be sure the terminal block’s protective plastic cover is reattached. If this cover is not reattached, an electrical shock could easily occur.

• Do not use power beyond the GP’s specified voltage range. Doing so may cause a fire or an electric shock.

GP-2400/2500/2600 Series User Manual 5

6

Preface

WARNINGS

Battery Replacement

• The GP uses a lithium battery for backing up its internal clock data. If the battery is incorrectly replaced, the battery may explode. To prevent this, please do not replace the battery yourself. When the battery needs to be replaced, please contact your local GP distributor.

Installation/Maintenance

• High voltage runs through the GP. Except for replacing the backlight, never take apart the GP, otherwise an electrical shock can occur.

• Do not modify the GP unit. Doing so may cause a fire or an electric shock.

• Do not use the GP in an environment where flammable gasses are present, since operating the GP may cause an explosion.

CAUTIONS

Installation/Maintenance

• Be sure to securely connect all cable connectors to the GP.

A loose connection may cause incorrect input or output.

Wiring

• Ground the GP’s FG line separately from other units’ FG lines. Putting these FG lines too close may cause an electric shock or unit malfunction. Be sure to use a grounding resistance of 100

or less and a 2mm 2 or thicker wire, or your country’s applicable standard.

• Correctly wire the GP, be sure that the rated voltage and terminal layout are within the designated range. If the voltage supplied differs from the rated voltage, or incorrect wiring or grounding is performed, it may cause a fire or unit malfunction.

GP-2400/2500/2600 Series User Manual

Preface

CAUTIONS

• Use only the designated torque to tighten the GP’s terminal block screws. If these screws are not tightened firmly, it may cause a short-circuit, fire, or GP malfunction.

• Be careful that metal filings and wiring debris do not fall inside the GP, since they can cause a fire, GP malfunction, or incorrect operation.

Touch Panel/CF Card

• The liquid crystal panel contains a powerful irritant and if for any reason the panel is damaged and this liquid contacts any part of your body, be sure to wash that area with running water for 15 minutes. If any of this liquid enters your eye, flush your eye for 15 minutes with running water and contact a physician.

• Prior to inserting or removing a CF Card, be sure to turn the GP’s CF Card ACCESS switch OFF and to confirm that the ACCESS lamp is not lit. If you do not, CF Card internal data may be damaged or lost.

• While a CF Card is being accessed, NEVER turn OFF or reset the GP, or insert or remove the CF Card. Prior to performing these operations, create and use a special GP application screen that will prevent access to the CF Card.

Unit Disposal

• When this unit is disposed of, it should be done so according to your country’s regulations for similar types of industrial waste.

GP-2400/2500/2600 Series User Manual 7

8

Preface

General Safety Precautions

• Do not strike the touch panel with a hard or pointed object, or press on the touch panel with too much force, since it may damage the touch panel or the display.

• Do not install the GP where the ambient temperature can exceed the allowed range. Doing so may cause the GP to malfunction or shorten its operation life.

• Do not restrict or limit the GP’s naturally occurring rear-face ventilation, or storing or using the GP in an environment that is too hot.

• Do not use this unit in areas where large, sudden temperature changes can occur. These changes can cause condensation to form inside the unit., possibly causing the unit to malfunction.

• Do not allow water, liquids, metal or charged particles to enter inside the GP’s case, since they can cause either a GP malfunction or an electrical shock.

• Do not use or store the GP in direct sunlight, or in excessively dusty or dirty environments.

• Do not store or use the unit where strong jolting or excessive vibration can occur.

• Do not store or use the GP where chemicals (such as organic solvents, etc.) and acids can evaporate, or where chemicals and acids are present in the air.

Corrosive chemicals: Acids, alkalines, liquids containing salt

Flammable chemicals: Organic Solvents

• Do not use paint thinner or organic solvents to clean the GP.

• Do not store or operate the LCD display in areas receiving direct sunlight, since the sun’s UV rays may cause the LCD display’s quality to deteriorate.

• Storing this unit in areas at a temperature lower than is recommended in this manual’s specifications may cause the LCD display’s liquid to congeal, which may damage the panel. Conversely, if the storage area’s temperature becomes higher than the allowed level, the LCD’s liquid will become isotropic, causing irreversible damage to the LCD.

Therefore, be sure to store the panel only in areas where temperatures are within those specified in this manual.

• Do not connect or disconnect the communication cable to the host machine while the power is ON.

• Due to the possibility of unexpected accidents, be sure to back up the GP’s screen data regularly.

GP-2400/2500/2600 Series User Manual

Preface

„ About the GP’s Display Panel

• The GP’s currently displayed data, its voltage *1 and brightness set-

ting each affect the intensity of Contouring. (i.e, when some parts of the screen are brighter than others, creating a wavelike pattern)

• There are minute grid-points (dark and light) on the Display Panel’s surface. This is part of the GP’s design and not a defect.

• Extended shadows, or “Crosstalk” may appear on the sides of screen images. This is normal for an LCD display.

• Sometimes the display area may look as if the display colors have changed. This is a common attribute of LCD’s and is not a defect.

• Displaying a single image for long periods can cause an afterimage to remain when the display is changed to another screen.

To prevent this effect:

• Do not display any single screen for a long period of time. Try to periodically change the screen display.

*1 If the GP’s voltage is at the very low end of its allowable range, it may effect the intensitly of contouring.

GP-2400/2500/2600 Series User Manual 9

Preface

GP2400/2500/2600 Series Models

The GP2400/2500/2600 Series refers to the following GP model numbers:

GP2000

Series

Series

GP-2400

Series

GP-2500

Series

GP-2600

Series

Model Name

GP-2500T

GP-2600T

Model Type

GP-2400T GP2400-TC41-24V

GP-2500L GP2500-LG41-24V

GP-2500S GP2500-SC41-24V

GP2500-TC11

GP2500-TC41-24V

GP2600-TC11

GP2600-TC41-24V

Comments

UL/c-UL (CSA) Approved,

CE Marked

UL/c-UL (CSA) Approved,

CE Marked

UL/c-UL (CSA) Approved,

CE Marked

*1

UL/c-UL (CSA) Approved,

CE Marked

*1

UL/c-UL (CSA) Approved,

CE Marked

*1 Units are compliant or incompliant to the UL/c-UL(CSA) and the CE Marking standards depending on their revisions. For distinguishing the revision, refer to

“Revisions”. (page 13)

10 GP-2400/2500/2600 Series User Manual

Preface

Package Contents

The GP’s packing box contains the items listed below. Please check to confirm that all items shown below have been included.

„

GP2400-TC41-24V,

GP2500-LG41-24V,GP2500-SC41-24V

GP2500-TC11,GP2500-TC41-24V

GP2600-TC11, GP2600-TC41-24V

Installation

Guide

„ 1 „

This unit has been carefully packed, with special attention to quality. However, should you find anything damaged or missing, please contact your local GP distributor immediately for prompt service.

*1 The included installation fasteners may have different shapes depending on unit models.

2.5.5 Installation Fasteners

The installation procedures are same for all unit models.

GP-2400/2500/2600 Series User Manual 11

Preface

12

UL/c-UL (CSA) Application Notes

GP2500-TC11* 1 and GP2600-TC11* 1 are UL/c-UL(CSA) approved units. (UL File

No.E231702)

The GP2400-TC41-24V, GP2500-LG41-24V, GP2500-SC41-24V, GP2500-TC41-

24V, and GP2600-TC41-24V are UL/c-UL (CSA) listed products. (UL file

No.E182139)

Model Type

UL registered format

GP2400-TC41-24V 2880061

GP2500-LG41-24V 2980078-01

GP2500-SC41-24V 2980078-02

GP2500-TC11 *1 3180021-01

GP2500-TC41-24V 2880045-01

GP2600-TC11 *1 3180021-02

GP2600-TC41-24V 2880045-02

A

{

{

{

{

B

Standard Classification

C D

{ {

{

{

{ {

{

{ {

{

E

{

{

{

{

F G

{ {

{ {

{

This unit conforms as a product to the following standards:

*1 Units are compliant or incompliant to the UL/c-UL(CSA) and the CE Marking standards depending on their revisions. For distinguishing the revision, refer to

“Revisions”. (page 13)

A)

„

Industrial Electrical Control Equipment

B)

„

3rd Edition, December 1, 2001)

C)

„

3 Hazardous (classified) Locations

D) „

Standard for Safety of Technology Equipment, including Electrical Business Equipment

E)

„

Safety Requirements of Electrical Equipment for Measurement,

Control and Laboratory

F)

„

Standard for Safety of Information Technology Equipment (The

3rd Edition, December 1, 2001)

G) „

Standard for Safety of Technology Equipment, including Electrical Business Equipment

<Cautions>

• The GP must be used as a built-in component of an end-use product.

• This unit must be used indoors only.

• This unit should be installed in the front face of a metal panel.

• If this unit is installed so as to cool itself naturally, be sure to install it in a vertical panel. Also, be sure that the GP unit is mounted at least 100 mm away from any adjacent structures or equipment. If these requirements are not met, the heat generated by the GP unit’s internal components may cause the unit to

GP-2400/2500/2600 Series User Manual

Preface fail to meet UL/c-UL standard requirements.

• Be sure to set the switch to turn the GP power OFF at the location where an operator can easily operate on an end-user product with the GP built-in. Use the switch that an electric current and voltage are considered appropriately.

• Be sure to make an end-user product with the GP built-in have the chassis structure conformed to UL60950.

UL1604 Conditions of Acceptability and Handling Cautions:

1. Power, input and output (I/O) wiring must be in accordance with Class I,

Division 2 wiring methods - Article 501- 4(b) of the National Electrical Code,

NFPA 70 within the United States, and in accordance with Section 18-152 of the Canadian Electrical Code for units installed within Canada.

2. Suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous

Locations.

3. WARNING: Explosion hazard - substitution of components may impair suitability for Class I, Division 2.

4. WARNING: Explosion hazard - when in hazardous locations, turn power OFF before replacing or wiring modules.

5. WARNING: Explosion hazard - do not disconnect equipment unless power has been switched OFF, or the area is known to be non-hazardous.

CE Marking Notes

The GP2400-TC41-24V, GP2500-LG41-24V, GP2500-SC41-24V, GP2500-TC41-

24V, and GP2600-TC41-24V are CE marked products that conform to EMC directives EN55011 Class A, EN61000-3-2, EN61000-3-3, EN61000-6-2 and

EN60950.

GP2500-TC11* 1 and GP2600-TC11* 1 are CE marked products that conform to

EMC directives and low-voltage directives. Those products conform to EN55011

Class A, EN61000-6-2 and EN60950.

*1 Supported with the product marked on Revision “3”. For distinguishing revision, refer to “Revisions”. (page 13)

For detailed CE marking information, please contact your local GP distributor.

Revisions

You can distinguish revision from the brand label or the revision sticker pasted on the

GP body. Revision is consisted of alphabets and numbers at the location marked with a “*” sign and a marker pen in the “Rev” field.

In the example below, as you can see “*” signs at locations where “D”, “1” and “2” should exist, revision is “D, 1, 2”.

DIGITAL ELECTRONICS CORP.

Brand Label

GP-2400/2500/2600 Series User Manual

Revision Sticker

13

Preface

Documentation Conventions

The list below describes the documentation conventions used in this manual.

Symbol

*1

1) , 2)

Meaning

Indicates important information or procedures that must be followed for correct and risk-free software/device operation.

Indicates useful or important supplemental information.

Indicates steps in a procedure. Be sure to perform these steps in the order given.

Refers to useful or important supplemental information.

Provides useful or important supplemental information.

Screen

Editor

PLC n:1

Indicates the Pro-Designer (version 4.0 or higher).

Abbreviation for Programmable Logic Controller.

Indicates a multi-link type connection is used.

14 GP-2400/2500/2600 Series User Manual

Chapter

1 Introduction

1. System Design

2. Accessories

1.1

System Design

The following diagram represents the main selection of devices connectable to the GP.

RUN Mode

Edit Mode

GP Unit

(1)

To an Ethernet Network

(5)

(4)

(3)

CF Card

GP077-CF20,GP077-CF30

Speaker

(Commercial type)

(6)

RS-232C Cable

GP410-IS00-O*1

RS-422 Cable

GP230-IS11-O*1

(7)

RS-422 Connector

Terminal Adapter

GP070-CN10-O*1

2 Port Adaptor II

Cable

GP070-MDCB11

Mitsubishi PLC A,

Q, C, FX Series’

2 Port Adaptor II

GP070-MD11

(8)

(8)

Mitsubishi PLC A-Series

Program Port I/F Cable

GP430-IP10-O

Mitsubishi PLC FX-Series

Program Port I/F Cable

GP430-IP11-O

(8)

Host Controller

PLC etc.

Bar-Code Reader

(Commercial Type)

GP-2400/2500/2600 Series User Manual 1-1

Chapter 1 - Introduction

GP Unit

(1)

To an

E t h e r n e t

Network

GP Interfaces

(1) Ethernet

PLC Interfaces

(6) RS-232C Port

(2) Tool Connector

(3) CF Card

(4) Sound (AUX)

(7) RS-422 Port

(8) Programming

Console Port

(5) Serial Interface (COM1, COM2)

(2)

Data Transfer

Cable

GPW-CB02

Personal

Computer

*2

(3)

CF Card

GP077-CF20,

GP077-CF30

*1 Certain types and models of PLCs cannot be connected.

Pro-Designer On-line Help

*2 For the full range of compatible PCs, refer to the following manual.

Pro-Designer On-line Help

Pro-Designer

1-2 GP-2400/2500/2600 Series User Manual

Chapter 1 - Introduction

1.2

Accessories

All optional equipment listed here is produced by Digital Electronics Corporation.

Product Name

Pro-Designer

Ver. 4.0 or later

Model No.

PS-DWE01-V40

Description

Software to be used to create the screen data using a personal computer.

Product Name Model No.

Screen Data Transfer

Cable

GPW-CB02

Description

Connects the GP to a personal computer.

Transfers screen data and user program(s).

Product Name

RS-232C cable

*1

RS-422C cables

*1

RS-422C

*1

(Connector terminal block conversion adapter)

Model No.

GP410-IS00-O

GP230-IS11-O

GP070-CN10-O

Interface cables between the host (PLC) and the

GP.

Description

Conversion adapter to convert serial data to RS-

422 format

2 Port Adapter II

GP070-MD11 Interface unit that allows use of both GP and

Mitsubishi A, Q, C and FX series equipment in the same location.

Connects the GP to 2 Port Adapter II.

2 Port Adapter II

Cable

Mitsubishi A Series

Programming Port

I/F cable

Mitsubishi FX Series

Programming Port

I/F cable

GP070-MDCB11

GP430-IP10-O

GP430-IP11-O

Connects directly to Mitsubishi's PLC I/F

Programming Console. Simultaneous use of program console, however, is not possible.

*1 For detailed information about range of connectable PLC.

Pro-Designer On-line Help

GP-2400/2500/2600 Series User Manual 1-3

Chapter 1 - Introduction

Product Name

CF Card

CF Card Adaptor

Model No.

GP077-CF20

GP077-CF30

GP077-CFAD10

Description

GP Series CF Card (16MB)

GP Series CF Card (32MB)

CFCard Adaptor for standard PC Card

Slot.

Product Name

Screen Protection Sheet

Model No.

PS400-DF00

(GP-2400 Series)

PSL-DF00

(GP-2500/2600 Series)

Description

Disposable protective and dirtresistant sheet for the GP’s screen. The GP’s touch panel can be used with this cover sheet attached. (5 sheets/set)

They are available separately as optional maintenance items.

Product Name

Backlight

Model No.

GP-2400T

PS400-BU00-MS

GP-2500S

PS500S-BU00

GP-2500T

GP577RT-BL00-MS

GP-2600T

PS600-BU00

Description

Replacement Backlight

Installation Fastener

GP070-AT01

Fasteners to attach the GP to a panel.

(4 fasteners/set)

Installation Gasket

Connector Cover

PS400-WP00-MS

(GP-2400 Series)

GP570-WP10-MS

(GP-2500/2600 Series)

PS-BH00

Provides a moisture resistant seal when installing the GP. Same as the seal included in the GP’s original equipment package.

Attaches to GP rear face connectors.

1-4 GP-2400/2500/2600 Series User Manual

Chapter

1. General Specifications

2. Functional Specifications

3. Interface Specifications

4. Part Names and Functions

5. Dimensions

2 Specifications

2.1

General Specifications

2.1.1 Electrical

Input Voltage

Rated Voltage

Power Consumption

Allowable Voltage Drop

Voltage Endurance

Insulation Resistance

AC100V

AC85V to AC132V

AC100V to AC240V *1

AC85V to AC265V *1

50VA or less

50VA or less(ACIN100V)

*1

,

85VA or less(ACIN240V)

*1

20ms or less

AC1500V 20mA for 1 minute

(between charging and FG terminals)

10M Ω or higher at DC500V

(between charging and FG terminals)

*1 Supported with the product marked on Revision “3”. For distinguishing revision, refer to “Revisions”. (page 13)

GP2500-TC41-24V/GP2600-TC41-24V

Input Voltage

Rated Voltage

Power Consumption

Allowable Voltage Drop

In-rush Current

Voltage Endurance

GP2400-TC41-24V

GP2500-LG41-24V, GP2500-SC41-24V,

GP2500-TC41-24V, GP2600-TC41-24V

28W or less

DC 24V

DC19.2V to DC28.8V

50W or less

10ms or less

30A or less

AC1000V 20mA for 1 minute

(between charging and FG terminals)

Insulation Resistance

10M Ω or higher at DC500V

(between charging and FG terminals)

GP-2400/2500/2600 Series User Manual 2-1

Chapter 2 - Specifications

2.1.2 Environmental

3.

Ambient Operating

Temperature

Storage Temperature

Ambient Humidity

Atmosheric Endurance

(GP Operation Altitude)

Dust

Atmosphere

Vibration Resistance

Noise Immunity

(via noise simulator)

Electrostatic Discharge

Immunity

GP2400-TC41-24V

GP2500-LG41-24V

GP2500-SC41-24V

GP2500-TC41-24V

GP2600-TC41-24V

0 o C to +50 o C

*1

GP2500-TC11

GP2600-TC11

-20 o C to +60 o C

10%RH to 90%RH

(Non condensing, wet bulb temperature: 39 o C or less)

800hPa to 1114hPa (2000 meters or lower)

0.1mg/m 3 or less (non-conductive levels)

Free of corrosive gasses

IEC61131-2 compliant

When vibration is NOT continuous

10Hz to 57Hz 0.075mm, 57Hz to 150Hz 9.8m/s 2

When vibration is continuous

10Hz to 57Hz 0.035mm, 57Hz to 150Hz 4.9m/s 2

X, Y, Z directions for 10 times (80min.)

Noise Voltage: 1000Vp-p

Pulse Duration: 1 µ s

Rise Time: 1ns

Noise Voltage: 1500Vp-p

Pulse Duration: 1 µ s

Rise Time: 1ns

6kV (complines with IEC 61000-4-2 Level3)

*1 When using GP-2600T in an environment where the temperature becomes or exceeds

40 o C for an extended period of time, the screen contrast level may decrease from its original level of brightness.

2-2 GP-2400/2500/2600 Series User Manual

Chapter 2 - Specifications

2.1.3 Structural

Grounding

Ratings

*1

(For front panel of installed unit)

Weight

Cooling Method

External Dimensions

GP-2400 Series GP-2500 Series GP-2600 Series

100 Ω or less, or your country's applicable standard

Equivalent to IP65f (JEM 1030)

NEMA#250 Type4X/12

1.7 kg (5.5lb) or less 3.5kg (7.7lb) or less

Natural air circulation

W215mm [8.46in] x

H170mm [6.69in] x D60mm [2.36in]

W317mm [12.48in] x H243mm [9.57in] x D58mm [2.28in]

*1 The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit’s level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP’s front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel’s plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the

GP’s operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, you need to replace the installation gasket regularly.

GP-2400/2500/2600 Series User Manual 2-3

Chapter 2 - Specifications

2.2

Functional Specifications

2.2.1 Display

Effective Display

Area

Language Fonts

Text

Type

Colors

Resolution

8x8 dots

8x16 dots

16x16 dots

32x32 dots

Font Sizes

Text Sizes

Touch Panel

Backlight

Brightness Control

Contrast

Adjustment

GP-2400 Series

TFT type color LCD

256, No blink* 1

/64 colors, 3-speed blink

640 x 480pixels

W149.8mm [5.90in.] x

H112.3mm [4.42in.]

GP-2500 Series

GP-2500L

Monochrome LCD

GP-2500S

STN type color LCD

GP-2500T

TFT type color LCD

GP-2500L

White, Black

GP-2500S

64 colors, 3-speed blink

GP-2500T

256, No blink*1

/64 colors, 3-speed blink

W211.2mm [8.34in.] x

H158.4mm [6.24in.]

GP-2600 Series

TFT type color LCD

256, No blink* 1

/64 colors, 3-speed blink

800 x 600pixels

W246mm [9.69in.] x

H184.5mm [7.26in.]

ASCII: (Code page 850) Alphanumeric (incl. Eur. characters)

Chinese: (GB2321-80 codes) simplified Chinese fonts

Japanese: ANK 158, Kanji : 6962 (JIS Standards 1 & 2)

Korean: (KSC5601 - 1992 codes) Hangul fonts

Taiwanese: (Big 5 codes) traditional Chinese fonts

80 Char. x 60 rows

80 Char. x 30 rows

40 Char. x 30 rows

20 Char. x 15 rows

100 Char. x 75 rows

100 Char. x 37 rows

50 Char. x 37 rows

25 Char. x 18 rows

Both height and width can be expanded 1, 2, 4, or 8 times.

8X8 dot font, 8X16 dot font, 16X16 dot font and 32X32 dot font

32 x 24 keys/ screen

(1 or 2 point touch)

40 x 30 keys/ screen

(1 or 2 point touch)

CFL (Service life: 50,000 hrs. at 25 o C and 24hr. operation)

4 levels of adjustment available via touch panel.

8 levels of adjustment available via touch panel.

(GP-2500L/S Only)

*1 Changing the “Colors” setting to “256 colors” will disable the blink feature on all of your project’s screens. If you wish to use the blink feature, do not change this setting to “256 colors”.

2-4 GP-2400/2500/2600 Series User Manual

Chapter 2 - Specifications

2.2.2 Memory

Application

Data Backup

8MB FLASH EPROM *1

512KB SRAM (uses lithium battery)

*2

*1 Pro-Designer and GP-PRO/PBIII (C-Package02) each use application memory differently.

*2 A Lithium battery’s lifetime is:

10 years when the battery’s ambient temperature is under 40 o C

4.1 years when the battery’s ambient temperature is under 50 o C

1.5 years when the battery’s ambient temperature is under 60 o C

When used for backup:

Approximately 60 days, with a fully charged battery

Approximately 6 days, with a half-charged battery

2.2.3 Clock

GP-2400 Series GP-2500 Series GP-2600 Series

+ 65 seconds/ month (at room temperature)

Clock Accuracy

The GP’s internal clock has a slight error. At normal operating temperatures and conditions, with the GP operating from its lithium battery, the degree of error is 65 seconds per month. Variations in operating conditions and battery life can cause this error to vary from -380 to +90 seconds per month. For systems where this degree of error will be a problem, the user should be sure to monitor this error and make adjustments when required.

GP-2400/2500/2600 Series User Manual 2-5

Chapter 2 - Specifications

2.2.4 Interfaces

Serial Interface

(COM1)

Serial Interface

(COM2)

Ethernet Interface

Tool Connector

CF Card Interface

Asynchronous Transmission:

RS232C/RS422

Data Length: 7 or 8 bits

Stop Bit: 1 or 2 bits

Parity: None, Odd or Even

Data Transmission Speed: 2400 to 115.2kbps

Asynchronous Transmission:

RS232C

Data Length: 7 or 8 bits

Stop Bit: 1 or 2 bits

Parity: None, Odd or Even

Data Transmission Speed: 2400 to 115.2kbps

IEEE802.3, 10BASE-T

Asynchronous TTL level nonprocedural command I/F

Used for transferring data to and from the Screen Editor.

1 slot

CF Card

Expansion

Interface

Not available (Pro-Designer does not support this interface.)

Printer Interface

AUX Input/Output

Sound Output

External Speaker Connection (Terminal Block)

Monaural 1CH

Speaker Output 70mW (Rated Load: 8W, Frequency: 1kHz)

Sound Line Out Output 2.7Vp-p (Rated Load:10kW)

Wire Gauge AWG28 to AWG16

2-6 GP-2400/2500/2600 Series User Manual

Chapter 2 - Specifications

2.3

Interface Specifications

2.3.1 Serial Interfaces (COM1)

This interface can be either RS-232C or RS-422. Connects GP to Host (PLC).

This interface uses a socket-type connector.

(D-Sub 25pin female)

1

Pin Assignments

13

SIO

14

25

19

20

21

22

15

16

17

18

23

24

25

11

12

13

14

9

10

7

8

Pin # Signal Name

1

2

FG

SD

5

6

3

4

RD

RS

CS

DR

SG

CD

TRMX

RDA

SDA

NC

NC

VCC

Frame ground

Condition

Send data (RS-232C)

Receive data (RS-232C)

Request send (RS-232C)

Clear send (RS-232C)

Data Set Ready (RS-232C)

Signal ground

Carrier detect (RS-232C)

Termination (RS-422)

Receive data A (RS-422)

Send data A (RS-422)

No connection (Reserved)

No connection (Reserved)

5V±5% output 0.25A

SDB

RDB

RI

CSB

ERB

ER

CSA

ERA

NC

NC

NC

Send data B (RS-422)

Receive data B (RS-422)

Ring Indicate (RS-232C)

Clear send B (RS-422)

Enable receive B (RS-422)

Enable receive (RS-232C)

Clear send A (RS-422)

Enable receive A (RS-422)

No connection (Reserved)

No connection (Reserved)

No connection (Reserved)

Recommended Connector: Dsub25pin plug XM2A-2501<made by OMRON>

Recommended Cover: Dsub25pin cover XM2S-2511<made by OMRON>

Jack Screws: XM2Z-0071<made by OMRON>

• Use rough metric type M2.6x0.45 p threads used to secure the cable’s set screws.

Recommended Cable: CO-MA-VV-SB5P x 28AWG <made by HITACHI Cable

Ltd.>

• To confirm your PLC’s connection specifications , refer to

Pro-Designer On-line Help

GP-2400/2500/2600 Series User Manual 2-7

Chapter 2 - Specifications

When creating your own cable, follow the instructions listed below:

<With RS-422>

• The following pairs of pin #’s must be connected to each other.

#18 (CSB) <—> #19 (ERB)

#21 (CSA) <—> #22 (ERA)

• When connecting the RS-422 cable and the #9 (TRMX) and #10 (RDA) points, a termination resistance of 100

is added between RDA and RDB.

• When making a cable for a Memory Link system, be sure to use a 4-wire type.

<With RS-232C>

• Do not use the following pins: 9 (TRMX), 10 (RDA), 11 (SDA), 15 (SDB), 16

(RDB), 18 (CSB), 19 (ERB), 21 (CSA), 22 (ERA).

• The #1 (FG) terminal should only be connected if it is required by the device being connected to.

• This unit’s serial port is not isolated, therefore, it is important that you connect the SG (Signal Ground) terminals. If this is not done, the RS422 circuit may be damaged.

• Pin 14 (VCC) DC5V output is not protected. To prevent damage or unit malfunction, be sure to use only the designated level of current.

This interface is used for RS-232C data transfer, and uses a plug-type connector.

Pin Assignments Pin No. Signal Name

(D-Sub 9pin male)

5

1

9

6

7

8

5

6

3

4

1

2

9

SG

DR

RS

CS

CD

RD

SD

ER

RI/VCC

Signal

Direction

Input

Input

Output

Output

Input

Output

Input

Input/Output

Condition

Carrier detect (RS-232C)

Receive data (RS-232C)

Send data (RS-232C)

Enable receive (RS-232C)

Signal Ground

Data Set Ready (RS-232C)

Request Send (RS-232C)

Clear send (RS-232C)

Ring Indicate (RS-232C)

+5V+5% 0.25A

Recommended Connector:

OMRON>

Dsub9pin socket XM2D-0901<made by

Recommended Cover: Dsub9pin cover XM2S-0913<made by OMRON>

Jack Screws: XM2Z-0073<made by OMRON>

Use inch type screws (#4-40UNC) as set screws.

Since Pin#9(RI/VCC) is unprotected, be sure to keep the output current in the rated range.

2-8 GP-2400/2500/2600 Series User Manual

Chapter 2 - Specifications

2.3.2 Sound Output

This interface is used for external reset, buzzer output, or sound output.

Pin Assingments

1

12

10

11

12

7

8

9

Pin # Signal Name

1 RESERVE Reserved

2 RESERVE Reserved

5

6

3

4

RESERVE

RESERVE

RESERVE

RESERVE

Reserved

Reserved

Reserved

Reserved

RESERVE

RESERVE

RESERVE

LINE OUT

Reserved

Reserved

Reserved

Condition

SP OUT Speaker Output

GND Ground

Sound Lineout Output

GP-2400/2500/2600 Series User Manual 2-9

Chapter 2 - Specifications

2.4

Part Names and Functions

E

A,B

Front

F G

C

A:Display Panel

The GP monitor screen displays the screen setup and corresponding host (PLC) data.

(All units)

B: Touch Panel

Performs any screen change operations and sends data to the PLC.

C: Status LED

This LED reflects the GP’s condition.

Color

OFF

Green

Orange

Indicates

No power input

Normal operation

Backlight is burned out

D H I

Rear

(GP-2500 Series, GP-2600 Series)

F

D P L M Q N I

(GP-2400 Series)

J

H

D: Power Input Terminal Block

Connects the power cord.

E: CF Card Expansion Interface

(GP-2500 Series, GP-2600 Series only)

Not available (Pro-Designer does not support this interface)

F: Expansion Unit Interface 1

Not available (Pro-Designer does not support this interface.).

G:Expansion Unit Interface 2

(GP-2500T , GP-2600 Series only)

Not available (Pro-Designer does not support this interface.)

H: CF Card Cover

Open this cover to see the CF Card Slot. When accessing the CF Card, this cover must be closed.

I: CF Card Access Lamp

If the CF Card Cover is closed when the CF

Card is inserted, the LED lamp turns ON. The

LED lamp will remain turned ON even if the

CF Card Cover is opened while the GP accesses the CF Card.

2-10 GP-2400/2500/2600 Series User Manual

Chapter 2 - Specifications

J K L M

J: CF Card Slot

Insert the CF Card in this slot.

K: Dip Switches

N O P Q

Bottom

(GP-2500 Series, GP-2600 Series)

Dip Switch

1

2

3

4

Description

CF Card starting setting.Starting control from CF Card.

(Reserved)

(Reserved)

Forcible closing setting of the CF Card cover.

ON

Can start from

CF Card.

Forcible closing enabled.

OFF

Cannot start from

CF Card.

Remarks

Requires CF Card to be able to start.

Forcible closing disabled.

Fix switches at “OFF”.

For emergency treatment when the CF

Card’s hatch broke.

O

L: Serial Interface (COM1)

Used for the RS-232C and RS-422 cables. Is connected to the Host (PLC.)

M: Serial Interface (COM2)

Uses RS-232C cable.

N: Printer Interface

Not available (Pro-Designer does not support this interface.).

O: Ethernet Interface

Used for Ethernet (10BASE-T).

The LED will change (turn ON, blink) according to the GP’s status.

Side

(GP-2400 Series) Color

Orange

Green

Indicates

Lights when power is turned ON, blinks during data transfer.

Turns ON when linked.

P: Sound Output Interface

Used for sound output.

Q: Tool Connector

The Data Transfer cable can be connected here.

GP-2400/2500/2600 Series User Manual 2-11

Chapter 2 - Specifications

2.5

Dimensions

2.5.1 GP-2400 Series External Dimensions

Unit: mm [in.]

Top

204 [8.03]

Front

215 [8.46]

8 [0.31]

Side

60 [2.36]

2.5.2 GP-2500 Series External Dimensions

Unit: mm [in.]

Top

301 [11.85]

Front

317 [12.48]

8 [0.31]

Side

58 [2.28]

2-12 GP-2400/2500/2600 Series User Manual

Chapter 2 - Specifications

2.5.3 GP-2600 Series External Dimensions

Unit: mm [in.]

Top

301 [11.85]

Front

317 [12.48]

8 [0.31]

Side

58 [2.28]

2.5.4 Panel Cut Dimensions

Unit: mm [in.]

204.5

+1

0

+0.04

0

4-R3 or less

Unit: mm [in.]

301.5

+1 +0.04

4-R3 or less

GP-2400/2500/2600 Series User Manual 2-13

Chapter 2 - Specifications

2.5.5 Installation Fasteners

Unit: mm [in.]

M5

31[1.22]

19.5[0.77]

16[0.63]

2-14 GP-2400/2500/2600 Series User Manual

Chapter

1. Installation

2. Wiring Cautions

3. Tool Connector

4. Ethernet Cable Connector

5. CF Card Installation and Removal

6. Sound Output

3 Installation and Wiring

3.1

Installation

3.1.1 Installation Procedures

Follow the steps given below when installing the GP.

It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to repelling water.

Place the GP on a level surface with the display panel facing downward. Check that the GP’s installation gasket is seated securely into the gasket’s groove, which runs around the perimeter of the panel’s frame.

For details about installing the gasket, refer to

6.1.2 Installation Gasket Check/Replacement

Rear

face

Installation

Gasket

• Before installing the GP into a cabinet or panel, check that the Installation gasket is securely attached to the unit.

• A gasket which has been used for a long period of time may have scratches or dirt on it, and could have lost much of its dust and drip resistance. Be sure to change the gasket periodically, or when scratches or dirt become visible.

• The conforming installation gasket types are PS400-WP00-MS (for

GP-2400 Series) and GP570-WP10-MS (for GP-2500/2600 Series).

• Do not insert the joint of the installation gasket in the corner of the

GP. If you do it, the joint will be pulled so that it may cause the installation gasket to be torn.

GP-2400/2500/2600 Series User Manual 3-1

Chapter 3 - Installation and Wiring

Create the correct sized opening required to install the GP, using the installation dimensions given.

2.5.4 GP Panel Cut Dimensions

The installation gasket, installation brackets and attachment screws are all required when installing the GP.

Panel

Panel Cut

Area

Check that the installation panel or cabinet’s surface is flat, in good condition and has no jagged edges. Also, if desired, metal reinforcing strips can be attached to the inside of the panel, near the Panel Cut, to increase the panel’s strength.

Panel thickness should be from 1.6mm [0.06in.] to 10mm [0.4in.]. Decide the panel’s thickness based on the level of panel strength required.

For easier maintenance, operation, and improved ventilation, be sure to install the GP at least 100 mm [3.94 in.] away from adjacent structures and other equipment.

3-2 GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

• Be sure that the ambient operation temperature and the ambient humidity are within their designated ranges. (When installing the GP in a cabinet or enclosure, the term “ambient operation temperature” indicates the cabinet or enclosure’s internal temperature.

• Be sure that heat from surrounding equipment does not cause the

GP to exceed its standard operating temperature.

• When installing the GP in a slanted panel, the panel face should not incline more than 30 o .

• When installing the GP in a slanted panel, and the panel face inclines more than 30 o , the ambient temperature must not exceed 40 o C. You may need to use forced air cooling (fan, A/C) to ensure the ambient operating temperature is 40 o C or below.

• When installing the GP vertically, position the unit so that the Power

Input Terminal Block is also vertical.

GP-2400/2500/2600 Series User Manual 3-3

Chapter 3 - Installation and Wiring

1) Insert the GP into the panel cut out, as shown here.

2) Insert the installation fasteners into the GP’s insertion slots, at the top and bottom of the unit.

(total: 4 slots)

The minimum number of fasteners required to install a GP unit is four (4), however, up to

10 fasteners can be used on a

GP-2500 Series or GP-2600

Series unit.

3) Insert each of the fasteners shown below. Be sure to pull the fastener back until it is flush with the rear of the attachment hole.

3-4 GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

4) Use a Phillips screw driver to tighten each fastener screw and secure the GP in place.

A torque of only 0.5 N•m is sufficient to tighten these screws. Do not use too much force, since it may damage the GP unit.

Depending on the panel condition, you can improve moisture resistant effect by increasing the number of installation fasteners. However, since GP-2400T has only four installation holes, you cannot increase it in this case.

GP-2400/2500/2600 Series User Manual 3-5

Chapter 3 - Installation and Wiring

3.2

Wiring Cautions

3.2.1 Connecting the Power Cord

WARNINGS

• To avoid an electric shock, be sure the power cord is unplugged from the power outlet when connecting the power terminals to the GP unit.

• The GP2400-TC41-24V, GP2500-LG41-24V, GP2500-

SC41-24V, GP2500-TC41-24V, and GP2600-TC41-24V are designed to use only DC24V power. Using any other level of power can damage both the power supply and the GP unit.

• For GP2500-TC11 and GP2600-TC11, units without revision “3” marked are for AC100V Input only. If you supply power inappropriate to the unit model, it will cause damage on the power supply and the GP unit.

• Since the GP is not equipped with the power switch, be sure to connect a breaker type power switch to the

GP’s power cord.

• Be sure to ground the GP’s FG terminal. Failure to do so can lead to an electrical shock or GP malfunction.

• To prevent the Ring Terminals from causing a short when the terminal block attachment screws are loosened, be sure to use sleeve-type Ring Terminals.

• When the FG terminal is connected, be sure the wire is grounded.

Not grounding the GP unit will result in excessive noise. Use your country’s applicable standard for grounding.

3.2.3 Grounding

• The SG and FG terminals are connected internally in the GP unit.

• When connecting the SG line to another device, be sure that the design of the system/connection does not produce a shorting loop.

• Wherever possible, use thick wires (max 2mm 2 ) for power terminals, and twist the exposed wire ends when connecting the Ring Terminals.

• Please use the following size crimp-on type Ring Terminals.

3-6 GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

L N FG

Power

Terminal

Block

L

N

FG

AC Input Live Line

AC Input Neutral Line

Grounding Terminal connected to the GP chassis.

GP2500-TC41-24V, GP2600-TC41-24V

+

Positive electrode

Negative electrode

Grounding Terminal connected to

FG the GP chassis.

1) Be sure that the GP’s power cord is not plugged in to the power supply.

2) Remove the Terminal Strip’s clear plastic cover.

3) Remove the screws from the three (3) middle terminals, position the Ring

Terminals as shown above and reattach the screws. (Check each wire to make sure the connections are correct)

4) Reattach the Terminal Strip’s clear plastic cover.

A torque of only 0.5 to 0.6 N•m is required to tighten an attachment screw.

GP-2400/2500/2600 Series User Manual 3-7

Chapter 3 - Installation and Wiring

3.2.2 Connecting the Power Supply voltage transformer

Twisted Lines

GP unit

• If the supplied voltage exceeds the

GP unit’s range, connect a voltage transformer.

Chapter 2 Specifi-

cations for the allowable voltage range.

noise reducing transformer

Twisted Lines

GP unit

M a i n

Power

GP

power

M a i n

Power

GP

power

GP unit input/output unit

• For between the line and ground, select a power supply that is low in noise. If there is an excess amount of noise, connect a noise reducing transformer.

Use Voltage and Noise Reducing transformers with capacities exceeding 100VA.

• When supplying power to the GP unit, please separate the input/ output and operation unit lines, as shown.

GP unit power

input/output

Input/ Output Power

Input/ Output Power main circuit

Motor

Operation

Unit

• To increase the noise resistance quality of the power cable, simply twist each power wire before attaching the Ring Terminal.

• The power supply cable must not be bundled or positioned close to main circuit lines (high voltage, high current), or input/output signal lines.

GP unit lightening surge absorber

• Connect a lightening surge absorber, as shown in the diagram, to deal with power surges.

• To avoid excess noise, make the power cable as short as possible.

• Be sure to ground the surge absorber (E1) separately from the GP unit (E2).

• Select a surge absorber that has a maximum circuit voltage greater than that of the peak voltage of the power supply.

3-8 GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

3.2.3 Grounding

CAUTION

Do not use common grounding, since it can lead to an accident or machine breakdown.

(a) Exclusive Grounding (BEST) *1

(b) Common Grounding (OK) *1

(c) Common Grounding (Not OK)

Connect the FG terminal found at the back of the GP to an exclusive ground. [diagram (a)].

• Check that the grounding resistance is less than 100

.

• The SG and FG terminals are connected internally in the

GP unit.

• When connecting the SG line to another device, be sure that the design of the system/ connection does not produce a shorting loop.

• The grounding wire should have a cross sectional area greater than 2mm 2 . Create the connection point as close to the GP unit as possible, and make the wire as short, as possible. When using a long grounding wire, replace the thin wire with a thicker wire, and place it in a duct.

If exclusive grounding is not possible, use a common connection point. [diagram (b)]

If the equipment does not function properly when grounded, disconnect the ground wire from the FG terminal.

3.2.4 I/O Signal Line Placement

Input and output signal lines must be separated from the power control cables for operating circuits.

If this is not possible, use a shielded cable and connect the shield to the GP’s frame.

*1 Use a grounding resistance of less than 100W and a 2mm 2 or greater thickness wire, or your country’s applicable standard. For details, contact your local GP distributor.

GP-2400/2500/2600 Series User Manual 3-9

Chapter 3 - Installation and Wiring

3.3

Tool Connector

The GP’s Data Transfer Cable can be attached to the GP unit’s Tool Connector.

WARNING

To prevent an electric shock, unplug the GP unit’s power cord from the main power supply prior to attaching or detaching any connector(s) to or from the GP.

Bottom Face

GP-2500 Series, GP-2600 Series

Rear Face

GP-2400 Series

Tool Connector

3.4 Ethernet Cable Connector

Use the following drawing to locate your GP unit’s Ethernet connector. The GP

Ethernet interface is IEEE802.3 compliant, and transmits data at 10Mbps.

Bottom Face

GP-2500 Series, GP-2600 Series

Side Face

GP-2400 Series

Ethernet Interface

(RJ-45 Connector)

• It is strongly recommended that your Ethernet network is installed by a trained engineer.

• You may not be able to use the 1:1 connection by a cross cable depending on PCs or network cards. Be sure to connect those with a hub.

3-10 GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

3.5

CF Card Installation and Removal

CAUTIONS

When using the GP Unit and a CF Card, follow the precautions below:

• Prior to inserting or removing a CF Card, be sure to turn the

GP unit’s CF Card ACCESS switch OFF and to confirm that the ACCESS lamp is not lit. If you do not, CF Card internal data may be damaged or lost.

• While a CF Card is being accessed, NEVER turn OFF or reset the GP, or insert or remove the CF Card. Prior to performing these operations, create and use a special GP application screen that will prevent access to the CF Card.

Pro-Designer On-line Help

• Prior to inserting a CF Card, familiarize yourself with the CF

Card’s front and rear face orientation, as well as the CF Card connector’s position. If the CF Card is not correctly positioned when it is inserted into the Mulit Unit, the CF Card’s internal data and the GP unit may be damaged or broken.

• Be sure to use only CF Cards manufactured by the Digital

Electronics Corporation. GP unit performance cannot be guaranteed when using another manufacturer’s CF Card.

• Once GP data is lost, it cannot be recovered. Since accidental data loss can occur at any time, be sure to back up all GP screen and CF Card data regularly.

• Be sure to follow the instructions given below to prevent the

CF Card’s internal data from being destroyed or a CF Card malfunction from occuring:

• DO NOT bend the CF Card.

• DO NOT drop or strike the CF Card against another object.

• Keep the CF Card dry.

• DO NOT touch the CF Card connectors.

• DO NOT disassemble or modify the CF Card.

GP-2400/2500/2600 Series User Manual 3-11

Chapter 3 - Installation and Wiring

Use the following steps to insert the CF Card in the GP. The procedure is the same for all GP2000 series units.

1) Slide the CF Card Cover in the direction shown here, then upwards to open the cover.

2) Insert the CF Card in the CF Card

Slot, until the ejector button is pushed forward.

3-12

3) Close the cover. (As shown.)

4) Confirm that the CF Card Access

LED turns ON. You cannot access to the CF Card with the CF Card cover opened. However, if the CF

Card is being accessed, the access will be continued even if you open it on the way.

Simply reverse the steps shown in the previous “Inserting CF Card” explanation.

Prior to removing the CF Card, confirm that the CF Card Access LED is turned

OFF.

GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

3.5.1 CF Card Handling

The CF Card has a data overwrite limit of approximately 100,000 times. Therefore, be sure to back up all CF Card data regularly to another storage media.

(100,000 times assumes the overwriting of 500KB of data in DOS format)

To view CF Card data on a personal computer, first, insert the CF Card into a CF

Card Adapter. Then, insert the adapter into your personal computer’s PC card slot.

Depending on your model personal computer, the CF Card’s data may not be able to be read correctly.

If your personal computer is not equipped with a PC card slot, please use a standard type PC Card or CF Card reader. All of Digital’s CF Card operation testing has been performed using the following equipment.

Manufacture Name Model

I-O DATA DEVICE, INC. CardDock-CF/P

Connection Type

Parallel port

The connection between a personal computer and CF Card reader has been tested using an IBM compatible machine. This does not mean, however, that all IBM compatible machine can be used. Please contact your PC or CF Card reader manufacturer directly for details.

GP-2400/2500/2600 Series User Manual 3-13

Chapter 3 - Installation and Wiring

3.6

Sound Output

3.6.1 Connecting Speaker Lines

Use the following steps to connect the speaker.

1) Rotate the screw lock terminal block’s two (2) levers in the direction shown

(downward), and remove the screw lock terminal block.

2) Unscrew #11 pin and #10 pin set screws (2nd and 3rd screws from the left).

3) Insert the Speaker’s GND line in #11 pin connector, and the SP OUT line in

#10 pin connector.

4) Confirm that each line (cable) is inserted completely, and retighten the two (2) set screws.

3-14 GP-2400/2500/2600 Series User Manual

Chapter 3 - Installation and Wiring

5) Reattach the screw lock terminal block to the GP.

GP-2400/2500/2600 Series User Manual 3-15

Memo

3-16 GP-2400/2500/2600 Series User Manual

1. Types of Settings

Chapter

4 Settings

4.1

Types of Settings

The settings required for the GP unit, when starting Runtime or when in RUN mode, are found in the Settings Menu.

To call up this menu:

1. Connect the GP unit’s power supply.

Pro-Designer Runtime must be installed. For installation instructions, refer to Pro-Designer Ver. 4.0 or later software’s On-line Help.

2. After the GP starts up, touch the upper left corner of the screen within 10 seconds to call up the menu. You can also enter Setting mode at any time by simultaneously touching the upper right corner, bottom right corner, and bottom left corner of the screen. Pro-Designer Runtime will restart and the [Settings

Menu] will appear.

3. In this mode, the two tabs, [Offline] and [System] are available. Simply touch the desired tab to bring up those settings.

The following screen shows the [Offline] area’s selections.

GP-2400/2500/2600 Series User Manual 4-1

Chapter 4 - Settings

• Network

• Backlight

• OP. Switch

• Buzzer

• Self Test

4-2

• Stylus

• Restart

• Language

• Date/Time

• Ver. Info.

• Memory

GP-2400/2500/2600 Series User Manual

Chapter 4 - Settings

4.1.1 Offline

The following information explains how to enter the GP unit’s network settings.

After making a change to the [Network] settings, be sure to restart the GP unit. Touching the [Network] screen’s [Yes] key will automatically restart the GP.

1. In the [Settings] menu, touch the [Offline] tab.

2. Touch the [Network] icon.

3. Touch/select any of the three fields ([IP Address, [Subnet Mask], or [Default

Gateway]) and a keypad will appear for data entry.

The following buzzer sound settings are available.

The factory setting is [Press Touch Object].

• [None]

• [Press Touch Object]

Selecting this will turn the buzzer off.

The buzzer will only sound when a Touch Object is touched.

• [Press Anyway On Panel] You cannot use this option with the GP units.

1. In the [Settings] menu, touch the [Offline] tab.

2. Touch the [Buzzer] icon.

3. Touch/select the desired buzzer mode.

GP-2400/2500/2600 Series User Manual 4-3

Chapter 4 - Settings

Here, three selections (modes) are available.

• Wait

To preserve the GP unit’s screen display elements and extend the life of the backlight, the backlight can be set to automatically turn off after a designated period of inactivity (idle time) elapses. The factory setting for this item is

[OFF].

• Enable Touch if Backlight is OFF

This setting designates if the touch panel is enabled or disabled when a backlight burnout is detected. When this feature is set to OFF, touch panel touch input is ignored, thereby preventing touch panel operation errors. The factory setting is [OFF]. (Checkbox is not set.)

Backlight burnout detection is performed via monitoring of the backlight’s current consumption. Therefore, certain types of backlight failures cannot be detected.

• Brightness

Four levels of brightness are available.

1. In the [Settings] menu, touch the [Offline] tab.

2. Touch the [Backlight] icon.

3. Touch/select the desired backlight brightness.

4. To automatically turn the backlight off after a specified period of time, touch the [Wait] selection and set the “idle time” period.

Performs the GP unit’s self test. For details, see 5.2 Self Test.

This setting item is for GP2000H Series units only.

4-4 GP-2400/2500/2600 Series User Manual

4.1.2 System

This setting is not required for GP series units.

Chapter 4 - Settings

Sets the GP unit’s date and time.

1. In the [Settings] menu, touch the [System] tab.

2. Touch the [Date/time] icon.

3. Touch/select the Date or Time field to call up a data entry keypad. Use this keypad to enter all time setting.

Restarts the GP.

1. In the [Settings] menu, touch the [System] tab.

2. Touch the [Restart] icon.

3. Touch/select the [Restart] button to restart the GP unit.

Calls up the Pro-Designer runtime version, and the version and build numbers for the current project.

1. In the [Settings] menu, touch the [System] tab.

2. Touch the [Ver. Info] icon.

Designates the language used with System screens and User Applications.

1. In the [Settings] menu, touch the [System] tab.

2. Touch the [Language] icon.

3. Touch/select the desired language for the [System] and [User Application] items.

GP-2400/2500/2600 Series User Manual 4-5

Chapter 4 - Settings

Displays the total amount of memory, and the amount of memory currently being used.

1. In the [Settings] menu, touch the [System] tab.

2. Touch the [Memory] icon.

4-6 GP-2400/2500/2600 Series User Manual

1. Troubleshooting Checklists

2. SELF TEST

Chapter

5 Troubleshooting

This section explains how to find and resolve GP unit problems.

The GP unit can be connected to a wide range of devices, including a host (PLC), however, this manual will not discuss every possible device, or problem. For problems not directly related to the GP unit, refer to that device’s manual.

The main problems that occur during use of the GP unit are:

1) The panel display is blank.

2) Connected devices cannot be used.

5.1

Troubleshooting Checklists

When a problem occurs, be sure to first read each checklist item and follow the instructions given.

If this does not solve the problem, please contact your local GP distributor.

For hardware and software problems, contact the distributor where you bought the

GP unit.

GP-2400/2500/2600 Series User Manual 5-1

Chapter 5 - Troubleshooting

5.1.1 No display

No.

Check Item/Operation

1 Are all Pro-Designer screens sent to the GP unit?

2 Is the [Initial Panel ID] set up correctly in Pro-Designer?

3 Is the GP unit’s status LED lit?

Y/N Countermeasure

If not, send to the GP.

If not, enter the [Initial Panel ID] and re-send the screen data.

If the LED is orange, the backlight is burned out. Please change the backlight.

See “6.3 Replacing the Backlight”

See “2.1.1 Electrical” 4 Is the voltage level within the designated range?

5 Turn the power supply OFF.

6 Are the power cable terminals correctly connected?

7 Turn the power supply ON.

8 Is the power lamp lit?

9 Is the backlight lit?

Did the above procedure correct the problem?

If not, connect the terminals correctly.

See “3.2 Wiring Cautions”

If not lit -> Hardware problem

If the backlight is burned out, please change the backlight.

See “6.3 Replacing the Backlight”

If not, -> Hardware problem

5.1.2 Connected devices cannot be used

No.

Check Item/Operation

1 Turn the power supply OFF.

2 Are the power cable terminals correctly connected?

3 Is the correct Device/PLC protocol and driver information set up in Pro-

Designer?

4 Is the Device/PLC connection cable correctly connected?

Y/N

Did the above procedure correct the problem?

Countermeasure

If not, connect the terminals correctly.

See “3.2 Wiring Cautions”

If not, enter the correct protocol and driver information.

Refer to the Device/PLC’s manual and correctly connect the cable.

See “3.2 Wiring Cautions”

If not, -> Hardware problem

5-2 GP-2400/2500/2600 Series User Manual

Chapter 5 - Troubleshooting

5.2

SELF TEST

The GP unit is equipped with a number of self diagnosis features used to check its

System and Interfaces for any problems.

5.2.1 SELF TEST item list

• Char. Pattern • Disp Pattern • Touch Panel

• COM 1 *1 • COM 2 *1 • Video Memory

*1 This item must be prepared by the user (cable, connector, etc.).

GP-2400/2500/2600 Series User Manual 5-3

Chapter 5 - Troubleshooting

5.2.2 SELF TEST - details

This section explains the contents of SELF TEST.

Checks each font’s pattern and kanji-characters’ROM. Used when kanji-characters do not display. If there is no error, the message [OK] will appear, if there is an error, the message [NG] will appear.

Used when the device contents will not display correctly to check the drawing function.

Touch Panel check. Checks if each touch cell highlights when pressed.

Checks the RS-232C and RS-422 SIO lines for areas where communication problems develop. To run the check, connecting the SIO cable is necessary. If all is normal, OK displays; if there is a problem, an error message appears.

The SIO cable wiring is as shown below.

COM1

RS-232C

COM1

RS-422

COM2

RS-232C

SD

RD

RS

CS

CD

ER

5

8

20

2

3

4

RDA 10

SDA

SDB

RDB

CSB

11

15

16

18

ERB

CSA

ERA

19

21

22

CD

RD

SD

ER

SG

DR

RS

CS

RI

6

7

4

5

8

9

1

2

3

This item is used to check video memory (memory used for screen display). Use this feature when your screen display is not correct. This result of this test will be either [OK] (no problem) or [NG](problem).

5-4 GP-2400/2500/2600 Series User Manual

Chapter

6 Maintenance

1. Regular Cleaning

2. Periodic Check Points

3. Replacing the Backlight

6.1

Regular Cleaning

6.1.1 Cleaning the Display

When the surface or the frame of the display gets dirty, soak a soft cloth in water with a neutral detergent, wring the cloth tightly, and wipe the display.

••••• Do not use paint thinner, organic solvents, or a strong acid compound to clean the unit.

••••• Do not use hard or pointed objects to operate the touch-screen panel, since it can damage the panel surface.

6.1.2 Installation Gasket Check/Replacement

The installation gasket protects the GP and improves its water resistance. For instructions on installing the GP’s gasket, refer to

Chapter 3 “Installation and Wiring”

A gasket which has been used for a long period of time may have scratches or dirt on it, and could have lost much of its water resistance. Be sure to change the gasket at least once a year, or when scratches or dirt become visible.

1. Place the GP on a flat, level surface facing the display face downwards.

2. Remove the gasket from the GP.

GP-2400/2500/2600 Series User Manual 6-1

Chapter 6 - Maintenance

3. Attach the new gasket to the GP.

Be sure to insert the gasket into the

GP’s groove so that the gasket’s groove sides are vertical.

4. Check if the gasket is attached to the GP correctly.

• The gasket must be inserted correctly into the groove for the GP’s moisture resistance to be equivalent to IP65f.

• Be sure the gasket’s seam is not inserted into any of the unit’s corners, only in the straight sections of the groove. Inserting it into a corner may lead to its eventually tearing.

• The upper surface of the gasket should protrude approximately 2mm out from the groove. Be sure to check that the gasket is correctly inserted before installing the GP into a panel.

Seam

6-2 GP-2400/2500/2600 Series User Manual

Chapter 6- Maintenance

6.2

Periodic Check Points

To keep your GP unit in its best condition, please inspect the following points periodically.

GP Operation Environment

• Is the operating temperature within the allowable range (0 o C to 50 o C )?

• Is the operating humidity within the specified range (10%RH to 90%RH, dry bulb temperature of 39 o C or less)?

• Is the operating atmosphere free of corrosive gasses?

Electrical Specifications

• Is the input voltage appropriate?

GP-2500T/GP2600T: AC85V to AC132V or AC85V to AC265V *1

GP2400-TC41-24V, GP2500-LG41-24V, GP2500-SC41-24V, GP2500-TC41-24V,

GP2600-TC41-24V: DC19.2V to DC28.8V

Related Items

• Are all power cords and cables connected properly? Have any become loose?

• Are all mounting brackets holding the unit securely?

• Are there many scratches or traces of dirt on the installation gasket?

*1 Units are compliant or incompliant to the UL/c-UL(CSA) and the CE Marking standards depending on their revisions. For distinguishing the revision, refer to

“Revisions”. (page 13)

GP-2400/2500/2600 Series User Manual 6-3

Chapter 6 - Maintenance

6.3

Replacing the Backlight

When the unit’s backlight burns out, the unit’s status LED will turn orange. If the

OFFLINE menu’s “USE TOUCHPANEL AFTER BACKLIGHT BURNS OUT” feature is set to “NO”, the GP’s touch panel will be disabled.

*1

GP2000 Series units use a CFL, long-life type backlight. The actual life of the backlight however, will vary depending on the GP’s operating conditions, and replacement may be required. A GP2000 Series backlight has a life of 50,000 hours (approx. 5.7 years, at 25 o C and 24 hour operation), when the backlight is lit continuously (time required for brightness to fall to half its normal level.)

WARNINGS

• To prevent an electric shock, be sure the GP’s power cord is unplugged from the power outlet prior to replacing the backlight.

• When the power has just been turned OFF, the unit and backlight are still very hot. Be sure to use gloves to prevent burns.

• The backlight is very fragile. Do not touch the glass tube directly or try to remove its power cord. If the glass tube breaks you may be injured.

Use the following table to check that you have ordered the correct backlight.

GP Model

GP2400-TC41-24V

GP2500-SC41-24V

GP2500-TC11

GP2500-TC41-24V

GP2600-TC11

GP2600-TC41-24V

Backlight Model

PS400-BU00-MS

PS500S-BU00

GP577RT-BL00-MS

PS600-BU00

The GP2500L’s backlights cannot be replaced by the customer.

When the backlights need to be replaced, please contact your local GP distributor.

For backlight replacement details, refer to the replacement backlight unit’s installation guide.

6-4

*1 If “NO” has been selected for the OFFLINE menu’s “FORCE RESET” feature,

Touch-Panel operation is disabled.

GP-2400/2500/2600 Series User Manual