Pocket Guide
LonWorks to Modbus RTU
Gateway
LED
No.
1.
Description
Color
Function
Service
Green
Flashing Green:
This node has an application but is not
yet installed in a network (unconfigured).
Rev 1.0
DOC. ABC-LON-RTU SLAVE
Off:
This node is configured and installed in a
network.
Solid Green:
This node is unconfigured and
applicationless. Indicates errors detected
by the Neuron Self-Test routine.
2.
Wink
Red
Off:
Normal state
Flashes Red:
A wink command is received on the
LonWorks network.
3.
Not used
-
-
4.
Module Status
Green/Red
Solid Green:
The module has been initiated correct
and is working ok.
Flashes Red:
Software error. Restart the module.
Solid Red:
A hardware error has occurred.
5.
Modbus activity
Green/Red
Solid Red:
at start and if no Modbus messages have
been received for more than 5 sec.
Solid Green:
after receiving correct Modbus message
and correct start-up
6.
Config error
Green/Red
Solid Green:
Normal state
Flashes Red:
No configuration saved in the gteway
HMS Industrial Networks
Germany
Japan
Sweden
U.S.A
+49 - 721 - 96472 - 0
+81 - 45 - 478 - 5340
+46 - 35 - 17 29 20
+1 - 773 - 404 - 2271
[email protected]
[email protected]
[email protected]
[email protected]
Installation and Startup Summary
This installation instruction requires that the LW-tool Modbus
configuration program is installed on the computer aimed for
the configuration of the Gateway. (LW-tool Modbus is available
on the Gateway LMS Resource CD or the website of HMS,
www.hms-networks.com)
1.
2.
3.
4.
5.
6.
7.
8.
Snap the Gateway on to the DIN-rail
Connect the LonWorks cable
Connect the serial RS232/422/485 cable
Connect a PC using the Configuration cable
Connect the power cable to the Gateway
Start the LW-tool Modbus program on the computer
Apply 24VDC power to the Gateway
Configure the Gateway with LW-tool, see separate
instructions for LW-tool Modbus configuration program
Pin
Description
1
+24V DC
2
GND
Pin
Description
1
+5V
ü
2
RS232 Rx
ü
3
RS232 Tx
ü
4
Not connected
5
Ground
6
RS422 Rx +
ü
7
RS422 RX -
ü
8
RS485 +/RS422 Tx+
ü
ü
9
RS485 -/RS422 Tx-
ü
ü
Pin
Description
1
Shield
2
-
3
-
4
Net B
5
Net A
RS232
ü
RS422
RS485
ü
ü
ü
ü

advertisement

Related manuals

Frequently Answers and Questions

What does the Green LED indicate?
Flashing Green: Unconfigured node with an application, Off: Configured and installed node, Solid Green: Unconfigured node without an application or errors detected by Neuron Self-Test.
What does the Wink Red LED indicate?
A wink command is received on the LonWorks network.
What does the Solid Green Module Status LED indicate?
The module has been initiated correctly and is working properly.
What does the Solid Red Module Status LED indicate?
A hardware error has occurred.
What does the Solid Red Modbus Activity LED indicate at startup?
No Modbus messages have been received for more than 5 seconds.
What does the Solid Green Modbus Activity LED indicate?
A correct Modbus message and correct startup have been received.
What does the Solid Green Config Error LED indicate?
Normal state.
What does the Flashing Red Config Error LED indicate?
No configuration saved in the gateway.

advertisement