The most manageable, most adaptable infrastructure for small IT environments

Integrating management into our product solutions, APC ™ by Schneider Electric ™ provides the answer to your customers rising energy costs and lack of on-site resources.

Our highly manageable power infrastructure allows energy usage monitoring, outlet control, and automation, and we keep installation costs down with our ready-to-install, easy-toconfigure products, making our solutions truly

“plug and play.”

Table of contents

NetShelter ™ SX solutions ......................................................................Page 3

NetShelter cable management ........................................................Page 7

Shelves and mounting hardware ..................................................Page 10

Rack components ..................................................................................Page 11

Open frame racks ..................................................................................Page 12

NetShelter CX ..........................................................................................Page 14

Specialty enclosures ............................................................................Page 16

Rack cooling and airflow management .....................................Page 16

Rack power distribution ......................................................................Page 18

NetBotz ™ security and environmental monitoring .............. Page 22

Software .................................................................................................... Page 24

LCD monitors and KVM switches .................................................Page 26

Smart UPS ™ .............................................................................................. Page 27

Symmetra ™ ...............................................................................................Page 34

Online resources and more ............................................................Page 36

2 | Solutions for network closets and server rooms

NetShelter SX enclosure features

More standard features for faster installation

1 Cable access roof

• Eight cable entry slots

• Toolless mounting of overhead cable trough system

• Snap-in mounting to allow easy roof removal and installation with cables in place

2 Integrated baying brackets

• Pre-installed on frame front and back

• Spacing options at 24 in or 600 mm

• Bays with other APC power and cooling products

3 Pre-installed levelling feet and casters

• Easily adjustable levelling from top down

• Casters standard on all enclosures

4 Toolless, zero U accessory channel

• Toollessly mount

Rack PDUs

• Toollessly mount vertical cable organizers

5 Easily adjustable vertical mounting rails

• Simple screw and cam engagement

• Captive screws - no loose hardware

• Easy visual alignment for quick adjustment

• Adjust in .25 in increments through enclosure

• Hole cutouts for 0U installation (AR8469) of APC Data Distribution Cable (DDC) accessories

6 Half-height side panels

• Easy and safe handling

• Quick release latch

• Lockable - same key as doors

• Enclosure width remains the same with or without sides attached

2

1

Other standard features include:

• Integrated electrical bonding of sides, doors, roof, and rails to frame

• Ventilated front and rear doors

• Split-rear ventilated rear doors for better clearance in hot aisle

• Numbered U positions front and back

• Open bottom for unobstructed under floor access

• 3000 lb (1365 kg) static load, 2250 lb (1025 kg) dynamic (rolling) load

• UL Listed

• Energy Information Administration (EIA)/ECA-310-E compliant

3 | Solutions for network closets and server rooms

NetShelter SX enclosure and selection

Applications for height

24U Enclosures - Remote offices and small spaces

42U Enclosures - Standard height used globally, designed to fit through standard doorways

45U Enclosures - Enclosures with additional

U-spaces for environments that standardize on a 45U 7 ft enclosure height

48U Enclosures - More U-spaces for more equipment in the same footprint

Applications for depth

32.5 in (825 mm) is the preferred depth for

AV equipment

42 in (1070 mm) is the standard depth and meets most low to medium density applications

The 47.5 in (1200 mm) NetShelter has double the toolless mounting locations for more Rack

PDU and cable management options (excluding

AR3x4x enclosures)

The 47 - 48 in (1195 - 1220 mm) depth enclosures are becoming the new standard because of increasing server depth crowding cable and power space

Applications for width

24 in (600 mm) wide enclosures are the standard for most server applications. For higher densities a deeper enclosure may be required

30 in (750 mm) wide enclosures offer more space for high capacity cable management and power distribution. Typically wider enclosures are used for networking applications but the extra side space is often requested in blade sever applications

NetShelter SKU

AR3100

AR3107

AR3150

AR3157

AR3300

AR3307

AR3350

AR3357

AR3140

AR3340

AR3347

AR3200

AR3104

AR3810

AR3812

AR3814

Height

42U

42U

48U

42U

42U

48U

48U

42U

48U

42U

48U

42U

24U

42U

42U

24U

Width

600 mm (24 in)

600 mm (24 in)

750 mm (30 in)

600 mm (24 in)

600 mm (24 in)

600 mm (24 in)

750 mm (30 in)

750 mm (30 in)

750 mm (30 in)

750 mm (30 in)

750 mm (30 in)

600 mm (24 in)

600 mm (24 in)

600 mm (24 in)

600 mm (24 in)

600 mm (24 in)

Depth

1070 mm (42 in)

1070 mm (42 in)

1070 mm (42 in)

1070 mm (42 in)

1200 mm (47.5 in)

1200 mm (47.5 in)

1200 mm (47.5 in)

1200 mm (47.5 in)

1070 mm (42 in)

1200 mm (47.5 in)

1200 mm (47.5 in)

1070 mm (42 in)

1070 mm (42 in)

825 mm (32.5 in)

825 mm (32.5 in)

825 mm (32.5 in)

Application

Low-medium density servers

Low-medium density servers

Networking and blade applications

Networking and blade applications

Medium-high density servers

Medium-high density servers

High density networking and blade applications

Networking and blade applications

High -density networking

Very high -density networking

Very high -density networking

2 x 20U compartments for colocation

Remote server applications

Audio visual applications

Audio visual applications

Audio visual applications

4 | Solutions for network closets and server rooms

NetShelter SX networking enclosure

Optimized NetShelter SX design for enhanced networking application support and a superior solution for side airflow

Cisco Nexus ® 7018, Catalyst ® , and MDS networking switches

Cable access roof

• Extra large cable access slots for high -density cabling and brush strips for air containment

• Two spring loaded pins allow for easy roof removal and installation with cables in place

1

2

1

Networking style mounting rails

• Easily align rails that adjust in .25 in increments

• Left vertical mounting rail contains additional cable channel

• Rail position preset to accommodate Cisco ® switches and cable management

2

3

Pre-installed vertical cable managers

• Front vertical mounting rails feature pre-installed single sided vertical cable managers

• Smooth plastic fingers provide proper bend radius for cables

3

4

Vertical mounting rails for side-to-side airflow

• Front right vertical mounting rail open for improved side airflow

4

AR3140 - 42U x 30 in W x 42 in D

AR3340 - 42U x 30 in W x 47.5 in D

AR3347 - 48U x 30 in W x 47.5 in D

Side airflow cooling

Support cooling for small and large networking switches mounted within an enclosure

• Side airflow solution (AR7742/AR7747) for Cisco Nexus 7018

• Side airflow duct kit (AR7715) mounts inside 30 in (750 mm) wide enclosures for Cisco 6509, 6513, 9509, 9513, and 9500 series switches

• Directs cool air at the front of the enclosure directly and predictably to the intake at the side of side airflow switches

• Consists of two duct assemblies that act as diverters, utilizing the existing fan power of the switch

• Systems of baffles are located throughout the enclosure to mitigate exhaust air from recirculating back into the air intake

AR3340 Networking enclosure and AR7742 side airflow solution for Nexus 7018

5 | Solutions for network closets and server rooms

Toolless accessories

Vertical cable management

APC specializes in toolless install accessories by the use of the zero U channels located in the rear of every

NetShelter SX enclosure

1 Vertical 0U accessory channels

• Allows toolless mounting of vertical Rack PDUs

• Toolless mount vertical cable organizers

• Additional vertical 0U accessory channels:

- AR7502 Vertical 0U accessory channel, 42U, qty. 2

- AR7552 Vertical 0U accessory channel, 45U, qty. 2

- AR7572 Vertical 0U accessory channel, 48U, qty. 2

- AR7511 Narrow vertical OU accessory channel, 42U

- AR7505 Vertical cable organizer, center rear mount

2 AR8442 - Vertical cable organizer, eight cable rings, zero U

• Supports 35 to 55 CAT 6/CAT 6A data cables

• Mounts toollessly on the vertical 0U accessory channel

3 AR8443A - Vertical fiber organizer

• Installs toollessly

• Takes up one bay of channel

• Fiber spool only kit available (AR8444)

4 AR8457 - Data distribution 0U SX panel

• Installs toollessly

• Takes up one bay of channel

• Toollessly mount up to four DDC cable heads,

24 ports for rack-to-rack connections

5 AR7710 - Cable containment brackets with rack PDU mounting

• Low profile vertical cable management

• Support 60 to 90 CAT 6/CAT 6A data cables

• Mount toollessly on the vertical 0U accessory channel

6 AR7711 - Zero U accessory bracket

• Mount Rack PDUs in rear facing orientation

• Support 3rd party accessories in numerous mounting configurations

• Mount 1U or 2U patch panels or other networking accessories

7 AR8621 - Hook-and-loop cable managers, qty. 10

• Mount toollessly on the vertical 0U accessory channel

• Secure and bundle cables with hook-and-loop ties

2

AR8442

AR7710

6 | Solutions for network closets and server rooms

5

3

AR8444

AR8621

7

>

1

AR8457

4

3

AR8443A

6

AR7711

NetShelter SX cable management

Server and networking applications

As the number of IT components within each rack enclosure continues to increase, so do the number of power and data cables. APC by Schneider Electric offers a large selection of vertical and horizontal cable managers to address today’s cable routing demands.

From toolless install ring-style managers for server applications to high -density finger-type managers for supporting patching and switches, APC by Schneider

Electric is a leader in innovative, application -driven solutions. Our unique overhead cable management system turns the top of the enclosure into a cable tray eliminating the need to use space under a raised floor and permitting better organization in non-raised floor environments.

APC by Schneider Electric has a strong history supporting the server applications in data centers around the world. The innovative, toolless, snap-in accessories have become the benchmark for server cable management.

2 1

High capacity cable managers can be used to support fiber and copper cable bundles.

1 for NetShelter SX 30 in (750 mm) wide enclosures (AR3x5x), supports 190 to 250 CAT

6A/CAT 6 data cables per section. 190 CAT 6A

(.25 in - .30 in dia.) per channel section. Each kit covers one corner of the enclosure

2

3 mounting rails of NetShelter SX 30 in (750 mm) wide enclosures (AR3x5x)

3 AR3150 with wide vertical mounting rails shown

AR3x5x 30 in wide enclosure with closed vertical mounting rails for server applications

7 | Solutions for network closets and server rooms

NetShelter SX cable management

Horizontal cable managers

Finger type horizontal cable managers

Cable managers for patching and cross-over applications featuring, smooth radius plastic fingers that protect the cable from kinking and binding. Hinged, snap-on covers provide a clean look and retain large cable bundles. Cable managers with

6 in fingers include hardware for double-sided configurations with two units.

• AR8602 - 1U horizontal cable manager with 4 in fingers and snap-on cover

• AR8600 - 2U horizontal cable manager with 4 in fingers and snap-on cover

• AR8601 - 2U double-sided horizontal cable manager with 4 in fingers and snap-on covers

• AR8612 - 1U horizontal cable manager with 6 in fingers and snap-on cover

• AR8606 - 2U horizontal cable manager with 6 in fingers and snap-on cover

• AR8603A - 2U horizontal cable manager with 6 in fingers, snap-on cover, rear cable pass-through holes, and slots for AR8008BLK/AR8016ABLK horizontal cable channel

• AR8605 - 3U horizontal cable manager with 6 in fingers, snap-on cover, rear cable pass-through holes, and cable channel slots

Ring type horizontal cable managers

Economical cable managers for patching applications featuring various configurations to meet specific needs

• AR8425A - 1U horizontal cable manager with 4 rings

• AR8426A - 2U horizontal cable manager with 4 rings

• AR8428 - 2U horizontal cable manager with 4 rings and pass-through holes

• AR8427A - 2U horizontal cable manager with multiple rings and small cable retainers

• AR8113A - Cable management rings (qty. 5 large, 5 small)

• AR7707 - Cable management rings 8 in deep for 30 in wide enclosures (AR3x5x), qty. 8

Horizontal cable management accessories

• AR8429 - 1U cable pass-through manager with brush strip

• AR8129 - Cable management arm for use with sliding shelves

• AR8008BLK - Horizontal cable side channel (18 to 30 in adjustment) for routing cable front-to-back between the standard wide rack mounting rails or AR8603 and AR8428 horizontal cable managers

• AR8016ABLK - Horizontal cable side channel (10 to 18 in adjustment) for routing cable front-to-back between the standard wide rack mounting rails or AR8603 and AR8428 horizontal cable manager

• AR7706 - Mounting rail brush strips for 30 in wide enclosures

(AR3x5x), qty. 6

8 | Solutions for network closets and server rooms

AR8603A

AR8606

AR8426A

AR8427A

AR7707

AR8429

AR7706

AR8605

AR8425A

AR8428

AR8113A

AR8129

AR8008BLK/AR8016ABLK

NetShelter SX cable management

Overhead cable troughs and partitions

• NetShelter enclosures feature the ability to integrate a system of troughs and partitions for routing power and data cable across the top of the enclosures

• Troughs and partitions reduce the need for expensive suspended cable tray systems

• Troughs and partitions install toollessly with snap-in tabs and have standard attachment points for cable ladder systems

• For information on other troughs and partitions not shown here see APC’s website

3 2

1

1 Power cable trough

• Supports power distribution cables

• Provides separation from data cables

• Data cables pass-through underneath to front partitioned area

• AR8561 - Cable trough, 24 in enclosures

• AR8571 - Cable trough, 30 in enclosures

2 Pass-through data cable partition

• Partitions the top of the enclosure into cable routing areas

• Pass-through hole provides cable access into multiple cable areas

• AR8163ABLK - Pass-through data partition, 24 in enclosures

• AR8173BLK - Pass-through data partition, 30 in enclosures

3

Solid data cable partition

• Partitions the top of the enclosure into cable routing areas

• Solid face provides clean appearance at the front of the enclosure

• AR8162ABLK - Solid data partition,

24 in enclosures

• AR8172BLK - Solid data partition,

30 in enclosures

Cable ladders and accessories

Cable ladders and attachment kits for routing power and data cabling overhead from rack to rack

Cable ladders and attachment kits SKU

Cable Ladder 6 in (AR8164AKIT

6 in ladder with attach kit)

Ladder accessories

AR8164ABLK Ladder Corner Clamp

AR8165ABLK Ladder Angle Clamp Cable Ladder 12 in (AR8165AKIT

12 in ladder with attach kit)

Alternate mounting -

Ladder to Power Troughs

Alternate mounting -

Ladder to Data Partitions

Ladder to NetShelter SX Roof

Ladder Elevation Bracket

Ladder to 2 Post Rack

AR8576

AR8177BLK

AR8168BLK

AR8186

AR8460

Ladder Stacking

Ladder Wall Termination

Ladder Clamp Kit

SKU

AR8461

AR8462

AR8463

AR8465

AR8169

AR8561 AR8162ABLK

AR8163ABLK

9 | Solutions for network closets and server rooms

Shelves and mounting hardware

Mounting accessories to aid in the installation of IT equipment and secure racks into position

Shelving

Fixed and sliding shelves to enable the mounting of tower units, monitors, and other equipment into the rack environment

• AR8105BLK - Fixed shelf 50 lb (22.7 kg)

• AR8122BLK - Fixed shelf 250 lb (114 kg)

• AR8123BLK - Sliding shelf 100 lb (45.5 kg)

• AR8128BLK - Sliding shelf 200 lb (91 kg)

• AR8422 - Double side fixed shelf for 2 post rack

• AR8126ABLK - 17 in Sliding keyboard shelf

• AR8127BLK - 19 in Sliding rotating keyboard shelf

• AR8006A - Misc. equipment support rails for 24 in wide enclosure

Bolt-down and stabilization

Stabilization plates and hardware to prevent tip-over in standalone rack applications and meet specific anchoring requirements

• AR7701 - NetShelter SX bolt-down kit - meets IBC seismic requirements

• AR7700 - NetShelter SX stabilization plate to prevent tipping when sliding out equipment

Miscellaneous mounting brackets

Variety of mounting brackets for mounting IT equipment

• AR7711 - Zero U multi-purpose accessory mounting bracket for side mounting of 1U/2U products and rack PDUs

• AR8150BLK – 23 to 19 in mounting adapter brackets for use with AR7510 23 in EIA mounting rails

Hardware kits

Available for additional hardware needs or to accommodate equipment mounted in varying mounting options

• AR8100 - M6 Cage nuts and screws, qty. 32

• AR8400 - #12-24 screws, qty. 100

• AR8005 - #10-32 cage nuts, qty. 36

10 | Solutions for network closets and server rooms

AR8105BLK

AR8128BLK

AR8126ABLK/AR8127BLK

AR7701

AR7711

AR8100

AR8122BLK

AR8422

AR8006A

AR7700

AR8150BLK

Rack components

Replacement doors, side panels, roofs

Standard doors, side panels, and roofs are available for all enclosure sizes. Check the enclosure product page options tab on www.apc.com for a list of these rack components.

Rails

Mounting rails

Vertical EIA rail mounting kits for different widths and depths

• AR7510 - 23 in (585 mm) EIA mounting rails for 42U x 30 in (750 mm) wide enclosures

AR7510

Specialty roofs, side panels and accessories

• AR7252 - Networking roof for high -density cabling 30 in (750 mm) wide x

42 in (1070 mm) deep

• AR7716 - Networking roof for high -density cabling 30 in (750 mm) wide x

42 in (1070 mm) deep

• AR7215 - NetShelter AV enclosure top mount conduit access adapter

• AR7209 - Open roof support bridge for overhead troughs and partitions

• AR7305A - NetShelter SX pass-through side panel 42U x 42 in deep

• AR7313 - NetShelter SX pass-through side panel 42U x 47.5 in deep

• AR7315 - NetShelter SX pass-through side panel 45U x 42 in deep

• AR7316 - NetShelter SX pass-through side panel 45U x 47.5 in deep

• AR7375 - NetShelter SX pass-through side panel 48U x 42 in deep

• AR7314 - NetShelter SX pass-through side panel 48U x 47.5 in deep

• AR7714 - Replacement snap-in brush strips for SX roofs

• ACF501 - Roof fan for 24 in wide x 42 in deep enclosures, 120 VAC

• ACF502 - Roof fan for 24 in wide x 42 in deep enclosures, 208-230 VAC

• ACF503 - Roof fan for 30 in wide x 42 in deep enclosures, 120 VAC

• ACF504 - Roof fan for 30 in wide x 42 in deep enclosures, 208-230 VAC

• ACF505 - Roof fan for NetShelter AV 24 in wide x 32.5 in deep, 115 VAC

• AR8132A - Combination lock handle for NetShelter SX enclosures, qty. 2

Recessed rail kits

Intermediate mounting rails for supporting shallow depth equipment

• AR7503 - 42U x 24 in (600 mm) wide

• AR7504 - 48U x 24 in (600 mm) wide

• AR7508 - 42U x 30 in (750 mm) wide

• AR7578 - 48U x 30 in (750 mm) wide

AR7503

AR7209

AR7714

AR7215 AR7252/AR7716 ACF503 AR8132A AR7305A

11 | Solutions for network closets and server rooms

Open frame racks

Vertical cable management

NetShelter 2 and 4 post open frame racks

The NetShelter 2 and 4 post open frame racks offer a quality solution for the economical installation of rackmountable equipment, where security at the individual rack level is not required. Open frame racks provide unobstructed airflow and fast, easy access to installed equipment, and can be paired with high -density vertical cable managers for maximum cable volume. The 2 post rack offers cost conscious customers a simple solution for supporting networking equipment and patching applications. The 4 post offers more strength and features for supporting servers and networking equipment. Recent improvements to the 4 post racks increase cable management options and flexibility.

Performance, high capacity, finger-type vertical cable managers

• Fits 2 and 4 post open frame racks

• Slam-to-latch full length door opens to left or right

• Cable management backplate or midspan bracket for toollessly mounting cable management accessories and Rack PDUs

• AR8615 - 6 in (152 mm) wide, single-sided

• AR8625 - 6 in (152 mm) wide, double-sided

• AR8635 - 10 in (253 mm) wide, single-sided

• AR8645 - 10 in (253 mm) wide, single-sided

• AR8665 - 12 in (304 mm) wide, single-sided

• AR8675 - 12 in (304 mm) wide, double-sided

AR8615/AR8625 AR8440A/AR8441A

Channel type vertical cable managers

• AR8440A - 3 in (91 mm) wide, black

• AR8441A - 6 in (152 mm) wide, black

2 Post rack

• Self squaring design

• 45U mounting spaces 84 in (2136 mm) tall

• Black finish

• 6061-T6 Structural grade aluminum

• Weight capacity (static load) 750.00 lbs (340.19 kg)

4 Post rack

• Threaded #12-24 holes (AR204A)

• Square holes for cage nuts and server mounts

(AR203A)

• New design for easier assembly

• Steel construction

• 44U mounting spaces 84 in (2136 mm) tall

• Black finish

• Multiple toolless mounting points for hook and loop fasteners

• Multi-position rack PDU mounting bracket

• Reversible stabilization plates

• Grounding inserts

• Weight capacity (static load) 2000.00 lbs (909 kg)

12 | Solutions for network closets and server rooms

Open frame racks

Applications

1

AR8444 – Cable slack spools

• Toollessly mounts on back panel

• Provides smooth radius support for cable slack

3

1

2

AR8621 – Toolless hook and loop cable managers

• 18 in (457 mm) straps for large data cable bundles

• Various mounting positions on back panel of vertical cable managers

3

AR8680 - Cable divider/organizer

• For creating multiple cable pathways within vertical cable managers

• Includes tie-off features for securing cabling using toolless hook-and-loop cable managers

(AR8621)

2

4

4 Vertical Rack PDUs and patching

• Cable management backplate (single-sided) or midspan brackets (double-sided) allow:

- Toollesslly mount, front or rear, multiple vertical Rack PDUs

- 19 in (483 mm) patch panels can be installed vertically (double-sided only)

Accessories

AR8652 – Rack PDU mounting bracket

• Mounts on sides as a spacer when using vertical cable managers between two racks

• Mounts on face of vertical rails, perpendicular, for single rack applications

• Designed to toollessly mount APC rack PDUs

AR8450A – Trough and partition adapter

• Provides mounting locations for APC overhead trough and partition cable management system

13 | Solutions for network closets and server rooms

NetShelter CX enclosure

Soundproofed “Server room in a box” which allows for

IT deployment wherever and whenever it is needed

Conveniently deploy servers and networking equipment in a quiet, ventilated, secure, and office-ready cabinet. The NetShelter CX is a cost-effective alternative for when there is no space, budget, or time for a traditional server room or wiring closet.

AR4038 - 38U AR4024 - 24U AR4018 - 18U

NetShelter CX features

Cable management

Full height vertical cable trays, front, middle, and rear of all units

Composite wood structure

Composite structure with acoustic foam lining keeps hardware quiet and secure

Integrated fan module

Each unit is outfitted with fan module providing up to 3.6 kW thermal capacity

Zero U rack PDU

Each unit includes a Basic Rack PDU (AP9567) pre-installed providing 13 available outlets with

AR4018, 12 with AR4024, and 11 with AR4038

Cable egress

Cable egress provides discrete and quiet exit of up to 400 CAT5/6 cables

Casters

Each unit sits on 4 casters, 2 swivel and

2 fixed for ease of deployment and mobility

AR4000MV

Standard features

Floor space requirements: Enclosures are designed to be placed directly against a wall.

Clearance of 200 mm / 8 in on both sides of the cabinet is essential for normal operation

Cooling system: 1 x ultra-low-noise exhaust fan module 1.2 kW maximum recommended total thermal load (or 4,100 BTU / hr).

1 module with AR4018, 2 with AR4024, and 3 with AR4038

Noise reduction: 18.5 dB broadband noise reduction, measured 39 in (1.0 m) in front of the enclosure (HP ® and Dell ® servers were used as noise source in noise reduction measurements)

Mobility:

• 4 x heavy duty castor-type wheels

• Front wheels have 360° rotation for maneuverability -- rear wheels have fixed front-to-back motion for stability

Rear and side access:

• Detachable rear side panels, left and right, for equipment installation and maintenance access

• Detachable rear fan modules gives completely open rear rack access

Cable management: 3 in (75 mm) width full-height vertical 0U accessory channels located on each side at the front, middle, and rear of the rack

Grounding: All equipment installed within a NetShelter CX should have conventional grounding via power cables, but unlike conventional metal-case cabinets, the

NetShelter CX has no requirement for additional grounding in the form of ground strapping or pipe earthing, etc. The enclosure shell is constructed entirely from non-conductive materials and the rack is completely isolated from outside contact

Door locking: Key operated lock

14 | Solutions for network closets and server rooms

NetShelter CX accessories - 18, 24, 38U

• AR4601 - Bolt down kit - 2 L shaped brackets secure the enclosure to the floor.

• AR4701 - Dust Filter pack for 18 and 24U.

Increases the Ingress protection rating (IP) from

IP44 to IP54 and reduces the risk of dust related equipment issues.

• AR4702 - Dust filter pack for 38U. Includes filters for bottom and top of enclosure air intake holes.

NetShelter CX accessories - Mini

• AR4000MV12U - 12U Vertical Mounting Rail Kit for NetShelter CX Mini. Converts basic enclosure to a 12U rack enclosure.

• AR4000MV-FR - Fixed rail kit for NetShelter

CX Mini provides 2 horizontal mounting ledges for equipment placement. Must be used with

AR4000MV12U vertical mounting rail kit.

• AR4601 - Bolt down kit - 2 L shaped brackets secure the enclosure to the floor.

Soundproofing

The NetShelter CX achieves 18.5 decibels of noise reduction. In real terms that means it is quiet enough to put in the open office and even quiet enough to sit next to it.

4 x servers in a conventional open-frame rack dBA

70

4 x servers in a NetShelter

CX AR4024 enclosure dBA

70

60

50

Server noise

Normal speech

60

Average background office noise

50

Normal speech

Average background office noise

Server noise

40 40

AR4601

AR4000MV

NetShelter CX Mini enclosure

The CX ‘Mini’ is a purpose built tower-server enclosure aimed at small, non-IT spaces such as

Home Office, School, AV, Small Office, and Remote

Office environments.

NetShelter CX Mini features

• Ventilation system - the ultra-low noise exhaust fan module has a 800W maximum recommended total thermal load

• Cable management - two cable-ports allow passage into and out of the enclosure for power and networking cables

• Mobility - 4 x office style casters

• Access - A detachable and lockable rear panel ensures security and quick access to the equipment inside

• Integrated power strip - Includes 3 IEC outlets and 2 sets of quantity of 3 regional specific equipment cords. The power strip is removeable to allow installation through the rear, without power-off equipment

15 | Solutions for network closets and server rooms

Speciality enclosures

NetShelter seismic enclosure

Enclosure designed for essential facilities and carrier applications in seismic environments.

Meets NEBS test standard GR-63-CORE Zone 4 at

1000 lb (454.5 kg) equipment load

• AR2144BLK - 42U x 24 in (600 mm) wide x 42 in

(1070 mm) deep, NEBS enclosure, with sides

• AR2145BLK - 42U x 24 in (600 mm) wide x 42 in

(1070 mm) deep, NEBS enclosure, without sides

NetShelter WX wall-mount enclosure

Support remote patching and networking applications in a convenient wall-mount rack with an easy install rear hinged section, and reversible doors

• AR100 - 13U x 23 in (580 mm) wide x 25 in

(630 mm) deep, wall mount enclosure with vented sides and glass front door

• AR100HD - 13U x 23 in (580 mm) wide x 25 in

(630 mm) deep, wall mount enclosure with vented sides and full vented front door

• AR8206ABLK - Roof fan tray 120 V

• AR8207BLK - Roof fan tray 208/230 V

• AR8359 - Caster kit for NetShelter WX

• AR8355 - Ventilation plates for NetShelter WX

AR2145BLK

AR100

Cooling and airflow management

Blanking panels

Covers open rack space to prevent air recirculation and reduce bypass airflow to improve cooling efficiency

• AR8136BLK - 1U toolless snap-in blanking panel, 10 pk

• AR8136BLK200 - 1U toolless snap-in blanking panel, 200 pk

• AR8108BLK - 1U standard metal blanking panel, 2 pk

• AR8101BLK - 1U, 2U, 4U, 8U, blanking panel kit

• AR7708 - NetShelter SX Air Recirculation

Prevention Kit for closing gaps and pass-through holes between side panels and equipment mounting rails

16 | Solutions for network closets and server rooms

AR8136BLK

AR8101BLK

Cooling and airflow management

Side airflow cooling

Support cooling for small and large networking switches mounted within networking enclosures

• AR7742 (42U)/AR7747 (48U) - Side airflow solution for Cisco Nexus 7018 attaches to sides of 47.5 in (1200 mm) deep enclosures

• AR7715 - Side airflow duct kit mounts inside 30 in

(750 mm) wide enclosures for Cisco 6509, 6513,

9509, 9513, and 9500 series switches

• Consists of two duct assemblies that act as diverters, utilizing the existing fan power of the switch

• Systems of baffles are located throughout the enclosure to mitigate exhaust air from recirculating back into the air intake

KoldLok ® raised floor grommets

Seal a variety of cutouts in a raised floor environment to reduce cold air leakage and improve cooling efficiency under the raised floor

• AR7720 - Integral raised floor grommet (enclosed) for new installation, 10 pk

• AR7730 - Surface mount raised floor grommet

(split) for existing cables, 10 pk

• AR7740 - Extended raised floor grommet to cover length of floor tile, 10 pk

AR7720

AR7740

AR7742

AR7715

Ducting only

Vertical Exhaust Duct (VED) for NetShelter SX is an easy to install, low-cost cooling option that can increase the efficiency of the attached cooling system

• AR7751 - VED for 24 in enclosures, short range

• AR7752 - VED for 24 in enclosures, tall range

• AR7753 - VED for 30 in enclosures, short range

• AR7754 - VED for 30 in enclosures, tall range

• AR7755 - Overhead cable extension for VED 24 in

• AR7756 - Overhead cable extension for VED 30 in

Roof fan trays available for 42 in

(1070 mm) deep enclosures, see

Rack Components on page 11.

Rack fan panel

2U rack mounted fan panel and accessories

• ACF600 - 2U Rack fan panel

• ACF601 - Rack fan panel temperature controller

• ACAC40000 - 2U vent panel with temperature display

• ACAC40001 - 2U vent panel

ACF600

AR7751 and AR7755 installed on AR3300 with cable management

17 | Solutions for network closets and server rooms

Rack power distribution

Global power densities are increasing and becoming more unpredictable. Whether deploying rack power distribution in a wiring closet, server room, or data center, APC by Schneider Electric offers a consistent way to meet a variety of power density applications up to 22 kW per strip.

APC Rack PDUs have sufficient power and receptacle outputs to meet high kW loads in a minimal amount of space. Their ease of installation accelerates speed of deployment and reduces installation costs. With advanced rack power distribution, APC offers real-time remote load monitoring of connected equipment and individual outlet power control for remote power recycling.

Manage power at the rack level with pinpoint control

• Basic Rack PDU - Entry-level power distribution for rack-mount equipment

• Metered Rack PDU - Advanced power distribution provides real-time remote monitoring of connected loads

• Switched Rack PDU - Premium power distribution allows remote control of individual outlets and monitoring of aggregate current consumption

• Metered-by-Outlet - Provide real-time remote monitoring of each individual outlet

• Rack automatic transfer switch - Provides redundant power to single-corded equipment

The Metered and Switched Rack PDU offers advanced features to meet today’s data center demands

Monitors input and all breakers on the strip

(local and remote) and offer user-customizable warning and overload settings, plus automated alarm notifications. Enables enhanced capacity management and network management.

• Web interface

• Telnet, SNMP

• Security

• Schneider Electric StruxureWare ™ for Data Centers

Rack PDU local display

Load indicator LEDs Serial connection: local configuration and out-ofband management

User interactive display for local access

Environmental monitoring port for external temperature/humidity probe

AP7000 series

Local 2-digit

LED current monitoring display

Network management: access, configure, and receive warnings from remote locations via Web,

SNMP, and Telnet

18 | Solutions for network closets and server rooms

AP8000 series

CAN In/Out ports for future functionality

Local USB port for flash firmware updates and downloading data/event logs (not to be used as serial port)

Rack power distribution selection

Basic Rack PDUs

Mounting

U-Space

Input

Circuit

120 V Input Voltage

Vertical, 0U 15A

Vertical, 0U

Vertical, 0U

Vertical, 0U

Horizontal, 1U

Horizontal, 1U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Horizontal, 1U

Horizontal, 1U

Horizontal, 1U

Horizontal, 1U

Horizontal, 1U 30A

208 V 3 Phase Input Voltage

Vertical, 0U 20A, 3ø

Vertical, 0U 20A, 3ø

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Horizontal, 1U

Horizontal, 2U

Horizontal, 2U

20A

Horizontal, 1U 20A

Horizontal, 1U 30A

208 V Input Voltage

Vertical, 0U 15A

20A

30A

15A

20A

20A

20A

20A

30A

20A

20A

20A

30A

20A, 3ø

20A, 3ø

20A, 3ø

20A, 3ø

50A, 3ø

50A, 3ø

50A, 3ø

50A, 3ø

50A, 3ø

50A, 3ø

30A, 3ø

30A, 3ø

Horizontal, 2U 30A, 3ø

415 V 3 Phase Input Voltage

Vertical, 0U 20A, 3ø

Nominal

Power

1.4 kW

1.9 kW

1.9 kW

2.9 kW

1.4 kW

1.9 kW

1.9 kW

2.9 kW

2.5 kW

3.3 kW

3.3 kW

3.3 kW

5.0 kW

3.3 kW

3.3 kW

3.3 kW

5.0 kW

5.0 kW

5.8 kW

5.8 kW

5.8 kW

5.8 kW

5.8 kW

5.8 kW

12.5 kW

12.5 kW

14.4 kW

14.4 kW

12.5 kW

14.4 kW

5.0 kW

5.0 kW

5.0 kW

11.5 kW

Input

Plug Type

NEMA 5-15P

NEMA L5-20P

NEMA L5-20P

NEMA L5-30P

NEMA 5-15P

NEMA 5-20P

NEMA L5-20P

NEMA L5-30P

IEC-320 C14

IEC-320 C20

IEC-320 C20

NEMA L6-20P

NEMA L6-30P

IEC-320 C20

IEC-320 C20

NEMA L6-20P

NEMA L6-30P

NEMA L6-30P

NEMA L21-20P

NEMA L21-20P

NEMA L21-20P

NEMA L21-20P

NEMA L21-20P

NEMA L21-20P

CS8365C

CS8365C

CS8365C

CS8365C

CS8365C

CS8365C

NEMA L14-30P

NEMA L14-30P

NEMA L14-30P

IEC309 3P+PE

Output Receptacles

(14)5-15

(24)5-20

(14)5-15

(24)5-20

(10)5-15

(10)5-20

(10)5-20

(10)5-20

(15)C13

(15)C13

(20)C13 (4)C19

(20)C13 (4)C19

(20)C13 (4)C19

(2)C19 (10)C13

(12)C13

(12)C13

(4)C19

(10)C13

(42)5-20

(42)5-20

(21)5-20 (6)L6-20

(21)5-20 (6)L6-20

(36)C13 (6)C19

(36)C13 (6)C19

(30)C13 (6)C19

(30)C13 (6)C19

(24)C13

(24)C13

(3)C13

(6)C19

(4)L6-20

(12)5-20

(4)L6-30

(4)C19 (2)L6-30

(4)C19 (2)L6-30

(6)C19

3 ft.

10 ft.

3 ft.

10 ft.

6 ft.

8 ft.

28 ft.

28 ft.

28 ft.

3 ft.

10 ft.

3 ft.

10 ft.

3 ft.

10 ft.

(36)C13 (6)C19 10 ft.

Cord

Length

12 ft.

10 ft.

12 ft.

10 ft.

12 ft.

12 ft.

12 ft.

12 ft.

6.5 ft.

8.2 ft.

10 ft.

10 ft.

10 ft.

8.2 ft.

8.2 ft.

12 ft.

10 ft.

12 ft.

SKU

AP7562

AP7592

AP7563

AP7593

AP7564

AP7594

AP7568

AP7598

AP7569

AP7599

AP7567A

AP7516

AP7581

AP7582

AP7584

AP7557NA

AP9568

AP9572

AP7552

AP7540

AP7541

AP9559

AP9565

AP9566

AP9570

AP9571A

AP9567

AP7530

AP9551

AP7532

AP9562

AP9563

AP9564

AP9560

19 | Solutions for network closets and server rooms

Rack power distribution selection

Metered Rack PDUs

Mounting U-Space Input Circuit

120 V input voltage

Vertical, 0U 15A

Vertical, 0U 20A

Vertical, 0U

Horizontal, 1U

Horizontal, 1U

Horizontal, 2U

208 V input voltage

Vertical, 0U

Vertical, 0U

Vertical, 0U

30A

15A

20A

30A

Vertical, 0U

Vertical, 0U

Vertical, 0U

Horizontal, 1U

Horizontal, 1U

Horizontal, 2U

15A

20A

20A

20A

30A

30A

15A

20A

30A

Nominal Power

1.4 kW

1.9 kW

2.9 kW

1.4 kW

1.9 kW

2.9 kW

Input Plug Type

NEMA 5-15P

NEMA L5-20P

NEMA L5-30P

NEMA 5-15P

NEMA L5-20P

NEMA L5-30P

2.5 kW

3.3 kW

3.3 kW

3.3 kW

5.0 kW

5.0 kW

2.5 kW

3.3 kW

5.0 kW

IEC-320 C14

NEMA L6-20P

NEMA L6-20P

IEC-320 C20

NEMA L6-30P

NEMA L6-30P

IEC-320 C14

IEC-320 C20

NEMA L6-30P

Output Receptacles

(16)5-15

(24)5-20

(24)5-20

(8)5-15

(8)5-20

(16)5-20

(16)C13

(20)C13 (4)C19

(18)C13

(18)C13

(2)C19

(2)C19

(20)C13 (4)C19

(36)C13 (6)C19

(8)C13

(8)C13

(12)C13 (4)C19

Cord Length

10 ft.

10 ft.

10 ft.

12 ft.

12 ft.

12 ft.

10 ft.

10 ft.

10 ft.

Inlet

10 ft.

10 ft.

6.5 ft.

8 ft.

12 ft.

SKU

AP7831

AP7830

AP7832

AP7800

AP7801

AP7802

AP7850

AP7840

AP8858NA3

AP8858

AP7841

AP8841

AP7820

AP7821

AP7811

Switched Rack PDUs

Mounting U-Space Input circuit

120 V Input voltage

Vertical, 0U 15A

Vertical, 0U 20A

Vertical, 0U

Horizontal, 1U

Horizontal, 1U

Horizontal, 2U

208 V Input voltage

Vertical, 0U

Vertical, 0U

Vertical, 0U

30A

15A

20A

30A

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Vertical, 0U

Horizontal, 1U

Horizontal, 1U

Horizontal, 2U

20A

20A

20A

20A

20A

30A

30A

30A

15A

20A

30A

Nominal power

1.4 kW

1.9 kW

2.9 kW

1.4 kW

1.9 kW

2.9 kW

3.3 kW

3.3 kW

3.3 kW

3.3 kW

3.3 kW

5.0 kW

5.0 kW

5.0 kW

2.5 kW

3.3 kW

5.0 kW

Input Plug Type

NEMA 5-15P

NEMA L5-20P

NEMA L5-30P

NEMA 5-15P

NEMA L5-20P

NEMA L5-30P

NEMA L6-20P

IEC-320 C20

NEMA L6-20P

NEMA L6-20P

IEC-320 C20

NEMA L6-30P

NEMA L6-30P

NEMA L6-30P

IEC-320 C14

IEC-320 C20

NEMA L6-30P

Output receptacles

(16)5-15

(24)5-20

(24)5-20

(8)5-15

(8)5-20

(16)5-20

(7)C13

(7)C13

(21)C13

(21)C13

(21)C13

(21)C13

(21)C13

(21)C13

(8)C13

(8)C13

(16)C13

(1)C19

(1)C19

(3)C19

(3)C19

(3)C19

(3)C19

(3)C19

(3)C19

Cord length

10 ft.

10 ft.

10 ft.

12 ft.

12 ft.

12 ft.

10 ft.

Inlet

10 ft.

10 ft.

Inlet

10 ft.

10 ft.

10 ft.

6.5 ft.

8 ft.

10 ft.

SKU

AP7931

AP7930

AP7932

AP7900

AP7901

AP7902

AP8958NA3

AP8958

AP7940

AP8959NA3

AP8959

AP8641

AP7941

AP8941

AP7920

AP7921

AP7911A

20 | Solutions for network closets and server rooms

Rack power distribution selection

Locking IEC Power Cords

PDU input

IEC C14

Straight

IEC C14

(3 right, 3 left)

IEC C20

Straight

IEC C20

(3 right, 3 left)

Server input Cord length Cords per SKU

IEC C13

2 ft.

6

4 ft 6

6 ft.

6

IEC C13

IEC C19

2 ft.

4 ft.

6 ft.

2 ft.

6

6

6

6

IEC C19

4 ft.

6 ft.

2 ft.

4 ft.

6

6

6

6

6 ft.

6

SKU

AP8702S

AP8704S

AP8706S

AP8702R

AP8704R

AP8706R

AP8712S

AP8714S

AP8716S

AP8712R

AP8714R

AP8716R

Environmental

Description

Temp. sensor

Temp. and humidity sensor

Connector type

RJ-45

RJ-45

Cord length

13 ft.

13 ft.

SKU

AP9335T

AP9335TH

Locking IEC power cords provide a mechanism to secure power cord connections to the Rack PDU when used with any AP8000 series unit.

Every AP8000 Rack PDU includes 1 input jack for environmental monitoring probes.

Rack ATS

Mounting U-Space

120 V Voltage

1

1

2

208 V Voltage

1

1

1

2

Input Circuit

15A

20A

30A

15A

20A

20A

30A

Input Plug Type

NEMA 5-15P

NEMA L5-20P

NEMA L5-30P

IEC C14 Inlet

IEC C20 Inlet

NEMA L6-20P

NEMA L6-30P

Output Receptacles

(8) 5-15

(10) 5-20

(16) 5-20

(12) C13

(8) C13, (1) C19

(8) C13, (1) C19

(16) C13, (2) C19

Cord Length

8 ft.

8 ft.

8 ft.

none none

8 ft.

8 ft.

SKU

AP7750

AP7752

AP7753

AP7721

AP7723

AP7730

AP7732

Rack-mount PDU accessories

Vertical-mount bracket kits for third-party enclosures and alternate mounting configurations.

Bracket kits

Vertical, 0U mounting brackets for Dell and Rittal enclosures

Vertical, 0U mounting brackets for HP enclosures

NetShelter SX, 0U accessory and Rack PDU multiple orientation mounting bracket

Horizontal to Vertical, OU mounting bracket for horizontal 1U

Rack PDUs

*Brackets for AP7000 series Rack PDUs only

SKU

AP7400*

AP7406*

AR7711

AR8417

Rack-mount transfer switches

Provides redundant power to singlecorded equipment.

21 | Solutions for network closets and server rooms

NetBotz security and environmental monitoring

Security and environmental monitoring for network closets to data centers

NetBotz

Surveillance

• Leverage NetBotz, Pelco ™ IP, and CCTV camera technology to monitor IT assets remotely

Management capabilities

• Alarming allows alerts, multiple notification methods, scheduling, graph and video attachments, and escalation

• StruxureWare Central available for centralized monitoring of multiple appliances

Environmental monitoring

• Wide range of sensor support to monitor the health of your IT assets

• Temperature, humidity, leak, door, smoke, vibration, dew point, airflow, dry contact, 4-20mA, and 0-5V

Access control

• Control and manage access privileges for APC

NetShelter SX enclosures over the network

NBWL0455

NBPD0160

NBRK0201

NBRK0451

High level security option for NetShelter SX

NetBotz rack access PX – HID system AP9361

• Configure individual HID proximity cards for access or schedule access to equipment for maintenance purposes

• Control and manage rack access privileges from a web browser

• Perform audit trails on rack access

• Receive alarm notification when the rack is in a compromised security state

AP9361

NetBotz rack access pod 170 – NBPD0171

• Rack access pod connects via A-Link and mounts in the rack basement, minimizing space usage

• Rack access solution scales easily and can be used with any NetShelter SX brand enclosures

NBPD0171

AP9361

NBPD0155

22 | Solutions for network closets and server rooms

NetBotz security and environmental monitoring

Features and benefits

Availability

• Prevent equipment failure from a full range of threatening environmental conditions

• Detect and prevent access to equipment from unauthorized personnel

• Real-time event notification minimizes response times to critical physical infrastructure situations.

Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime

• Detect and record motion, allowing a visual record to be paired with an access or environmental alert, which speeds root cause analysis

• Video storage prompted by motion or alert

• Grant authorized people access to equipment through proximity card authentication

Protection

• User-selectable password protection prevents unauthorized access

• Share access without risking unauthorized configuration changes with read-only options

Agility

• Customize threshold definitions (multiple thresholds per sensor, scheduling, severity levels) to individual requirements

• Alerts are managed according to user specific escalation policies and received in multiple formats

• Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc.

• View the user interface with a browser or from a mobile device. Provides quick access from anywhere on a secure network

• Video storage prompted by motion or alert

Manageability

• Robust appliance interface provides historic alerts, graphs, and configuration

• Easily review and correlate alerts. Provide context to alerts by attaching video clips, graphs, and maps

• Integrates seamlessly with StruxureWare Central

" Anchor Glass Container Corporation is the third-largest manufacturer of glass containers in the United States. Our NetBotz monitoring gives us the peace of mind of having a complete monitoring picture and understanding of our data center environment."

- Dennis W. Grow

Manager MIS Technical Service

Anchor Glass Container Corp.

23 | Solutions for network closets and server rooms

StruxureWare Central

Centralized, multi-vendor, real-time monitoring of data center physical infrastructure

StruxureWare Central is easy to use and deploy with a user-friendly interface to monitor, manage, and control the hundreds or thousands of devices a company might have from a wide range of manufacturers.

These devices include equipment that provides power, cooling, security, and environmental monitoring.

• Multi-vendor – capable of monitoring any networked device from any manufacturer

• Real-time monitoring, user-defined reports and graphs, and instant fault notification and escalation enable quick resolution of critical infrastructure events.

• Centralized repository – of critical information accessible by multiple users from anywhere on the network.

• Customized alarming – alarm and escalate by device, by rack, by location to the right people at the right time.

• Open and flexible architecture – expands with changing business needs through additional device licenses, add-on surveillance, operations, capacity, and change modules.

24 | Solutions for network closets and server rooms

StruxureWare Central options

Specifications

SKU

Device Support

(1 node = 1 IP address)

Basic

AP9465

Up to 525 devices

Standard

AP9470

Up to 2,025 devices

Enterprise

AP9475

Up to 4,025 devices

Virtual Machine

AP94VMTRL AP94VMACT

Up to 5 devices Up to 325 devices with

(1) CPU and (1) GB RAM

Up to 1,025 devices with

(1) CPU and (2) GB RAM

Up to 2,025 devices with

(2) CPU and (2) GB RAM

Up to 4,025 devices with

(4) CPU and (4) GB RAM

Up to 250 appliances NetBotz Appliance

Surveillance Support

StruxureWare Operations

StruxureWare Capacity

StruxureWare Mobile

StruxureWare Energy Efficiency

StruxureWare Energy Cost

StruxureWare Change

Building Management

System Integration

Multi-vendor SNMP and

ModBus Support

Up to 15 appliances

Up to 20 racks

Yes

Yes

Up to 125 appliances

Up to 200 racks

Yes

Yes

Up to 250 appliances

Yes

Yes

Up to 1 appliance

Up to 1,000 racks (2,500 nodes)

Yes

Yes

Power

Supported device types

All: UPS Models, Chillers, Power

Distribution Units (PDU), Rack

PDUs, Computer Room Air

Conditioners, Environmental

Sensors, Power Metering

Equipment, Surveillance

Appliances, Static Transfer

Switches, Standby Generators

Single supply

Yes

Single supply

Yes

Dual supply

Yes n/a

Yes

Client system and web browser prerequisites

Operating system Microsoft ® Windows ® , XP SP2, Server 2003, Vista or Red Hat Enterprise, Linux 5.x (32-bit platforms only)

CPU speed

System memory

Screen resolution

1 GHz or better AMD/Intel processor

1GB RAM

1024 x 768

Browser requirements

Communication and storage

On-board RAM

The browser must be JavaScript ® enabled, MozillaFirefox ® version 3.0.8 or higher, Microsoft Internet Explorer ® version 6.0 or higher

1 GB 2 GB 4 GB See “Supports VMware ® Fault

Tolerance”/“High Availability”

Data storage

Support VMware fault tolerance

Support VMware high availability

Protocols

160 GB available for data storage n/a n/a

250 GB available for data storage n/a n/a

1 TB available for data storage n/a n/a

DNS, HTTP, HTTPS, SMS, SMTP, SSL, TCP/IP, SNMP

18 GB minimum (includes required space for VM image and 1GB of data storage)

(1) CPU, (1) GB RAM, up to 325 devices

(1) CPU, (2) GB RAM, up to 1,025 devices

(1) CPU, (1) GB RAM, up to 325 devices

(1) CPU, (2) GB RAM, up to 1,025 devices

(2) CPU, (2) GB RAM, up to 2,025 devices

(4) CPU, (4) GB RAM, up to 4,025 devices

DNS, HTTP, HTTPS, SMS, SMTP, SSL, TCP/IP,

SNMP, Modbus TCP

Network interface connections RJ-45 10/100/1000 Base-T

25 | Solutions for network closets and server rooms

LCD monitors and KVM switches

Optimize rack space.

Maximize system visibility.

APC Rack LCD Consoles are a keyboard, mouse,

17 in/19 in LCD console, and optional integrated

8/16 port analog KVM Switch (17 in model only) all in a compact 1U design. This compact design allows a KVM switch to be mounted in the rear of the Rack LCD Console, or, eliminate the need for a separate KVM switch altogether by choosing a Rack

LCD Console with Integrated 8/16 port analog KVM

Switch. The console is easily installed and minimizes support and maintenance costs, ensuring lower cost of ownership. The ultra-thin LCD screen, touchpad technology, and easy-to-install single user rack mount kit combine to form a high-quality, streamlined solution built for server management. The Rack LCD

Consoles can be used in a variety of IT environments, from computer rooms to large data centers.

• Ultra-thin 17 in or 19 in LCD Monitor

• Integrated keyboard with number pad

• USB Port for external media

• Space-saving 1U design

• Touchpad mouse

• Easy to install

LCD Console

17 inch Rack LCD Console

19 inch Rack LCD Console

SKU

AP5717

AP5719

AP5808

LCD Console with Integrated KVM Switch

17 inch Rack LCD Console with Integrated 8-port KVM Switch

17 inch Rack LCD Console with Integrated 16-port KVM Switch

KVM USB Cable, 6 ft. (1.8 m)

KVM USB Cable, 12 ft. (3 m)

KVM USB Cable, 25 ft. (5 m)

SKU

AP5808

AP5816

AP5821

AP5822

AP5823

AP5816

Access your servers across the room or across the world

APC Rack KVM switches empower IT administrators through both local and remote POST and BIOSlevel access and control of connected servers. APC

Analog, CAT-5 Analog, and IP KVM switches help reduce total cost of ownership--minimizing space, hardware, electricity, and cabling by leveraging just one keyboard, monitor, and mouse for multiple servers. Improve return on investment and flexibility through enterprise-level scalability with centralized management. IT infrastructure management in data centers, computer rooms, and remote branch offices is now possible with greater control and peace of mind with APC Rack KVM switches.

KVM Switches with Coaxial Type Connection

8-port Analog KVM

16-port Analog KVM

AP5201

SKU

AP5201

AP5202

KVM Switches with CAT-5 Type Connection

32-port Digital Enterprise IP KVM with Virtual Media, 2 remote users

16-port Digital Enterprise IP KVM with Virtual Media, 2 remote users

16-port Digital IP KVM with Virtual Media, 1 remote users

16-port Analog Enterprise KVM with Virtual Media, 2 local users

16-port Analog KVM, 1 local users

8-port Analog KVM, 1 local users

KVM USB Server Module

KVM PS/2 Server Module

KVM USB Server Module with Virtual Media

KVM PS/2 Server Module with Virtual Media

KVM USB Server Module with Virtual Media and CAC Support

KVM Serial Server Module

KVM to APC Rack PDU Power Management Cable

KVM 1U Bracket for rearmount behind Rack LCD Console

KVM Access Software License Upgrade to Enterprise (1024 Nodes)

Cables

KVM USB cable

KVM PS/2 cable

KVM Daisy-Chain cable

2ft

AP5262

3ft

AP5264

6ft

AP5253

AP5250

AP5263

12ft

AP5257

AP5254

SKU

KVM2132P

KVM2116P

KVM1116P

KVM0216A

KVM0116A

KVM0108A

KVM-USB

KVM-PS2

KVM-USBVM

KVM-PS2VM

KVM-USBVMCAC

KVM-SERIAL

AP5641

KVM-LCDMOUNT

SEKVM1024N

25ft

AP5261

AP5258

26 | Solutions for network closets and server rooms

APC Smart-UPS

Advanced line interactive power protection for servers and network equipment

The world’s most popular network and server UPS

Award-winning Smart-UPS protects critical data by supplying reliable, network-grade power in either traditional tower or rack-optimized convertible form factor. Included PowerChute ™ management software provides IT administrators the comfort of safe system shutdown and advanced UPS management.

2

1

3

4

Tower 750-3000 VA

5

6

7

Standard features:

1 Alpha/numeric LCD display

Intuitive interface provides detailed and accurate information with ability to configure locally.

2

High efficiency green mode

Optimum efficiency which saves utility and cooling costs.

3 Network grade power conditioning

Extended range automatic voltage regulation

(AVR), noise filtering, and surge protection.

4 Advanced battery management

Temperature compensated charging extends life and advanced algorithms recommend replacement date.

5

Communication ports

Serial, USB, and Smart-slot for accessory cards.

6 Switched outlet group

Reboot hung devices, shed non-critical loads to conserve runtime, sequenced start-up/ turn off.

7 Battery disconnect

Convenient way to disconnect battery for transport.

27 | Solutions for network closets and server rooms

APC Smart-UPS Extended Run

Convertible extended run models ideal for critical servers and voice/data switches

1

2

3

Extended Run 750-1500VA

4

6

5

Additional features from standard:

1 Slim 2U Rack/Tower convertible form

Display rotates easily for use in or out of a rack.

2 High frequency design

Reduces size of (or eliminates) bulky transformers making installation even easier.

3 Models available with pre-installed network cards

Models with “NC” suffix have pre-installed

AP9631 network cards with temperature monitoring.

4

Smart external battery connector

Accept external batteries and increases runtime automatically to increase availability.

5 Switched outlet groups

Reboot hung devices, shed non-critical loads to conserve runtime, sequenced start-up/turn off.

6 Emergency power off (EPO)

Provides for remote UPS shutoff in the event of a fire or other emergency.

28 | Solutions for network closets and server rooms

APC Smart-UPS display

Intuitive, easy to use LCD interface

1 LCD Display Screen

Clear, consistent, and detailed information in your choice of basic or advanced menus.

Power Status

• Operating mode and efficiency

• Load VA/Watts/Amps

• Input/Output Voltage and frequency

• Battery capacity and runtime

• Energy meter and more

Control

• UPS and outlet group settings

Configuration

• Language

• Power quality setting

• Sensitivity

• Voltage transfer points

• Alarm, delay, and threshold settings

Test and diagnostics

• Initiate battery and runtime calibration tests

Logs

• See explanation of last ten transfers and faults

About

• UPS and replacement battery part numbers

• Serial numbers

• Battery install and suggested replacement dates

2 High frequency design

Reduces size of (or eliminates) bulky transformers making installation even easier.

3 Models available with Pre-installed network cards

Models with “NC” suffix have pre-installed

AP9631 network cards with temperature monitoring.

4 Smart external battery connector

Accept external batteries and increases runtime automatically to increase availability.

5 Switched outlet groups

Reboot hung devices, shed non-critical loads to conserve runtime, sequenced start-up/turn off.

2

1

3

4

5

On all SMT and SMX models

29 | Solutions for network closets and server rooms

Standard tower models

Product feature

Output

Power capacity

Nominal output voltage

Output frequency

Wave form type

Output connections

Input

Nominal input voltage

Input voltage range for main operations

(Max adjustable range)

Input frequency

Input connection

Batteries and runtime

Battery type

Typical backup time at 1/2 Load (minutes)

Typical backup time at full Load (minutes)

Replacement battery

Communication and management

Interface ports

Control panel and audible alarms

Emergency power off (EPO)

Surge protection and filtering

Surge energy rating

Filtering

Physical

Maximum height (inches)

Maximum width (inches)

Maximum depth (inches)

Net weight (lbs)

Conformance

Regulatory

Warranty and equipment protection policy

SMT750

500 W/750 VA

(6) NEMA 5-15R

670 W/1000 VA 980 W/1500 VA

120 V

57-63Hz

Sine wave

(8) NEMA 5-15R

120 V

82-144 V (75-154 V)

50/60 Hz +/-3 Hz (auto sensing)

NEMA 5-15P, 6 ft cord NEMA 5-20P

15.9

4.6

RBC48

Maintenance-free sealed lead-acid battery with suspended electrolyte, leak proof

20.6

23.9

24.1

6.1

RBC6

6.7

RBC7

6.7

RBC55

13.6

5.5

540J 459J

Full time multi-pole noise filtering: 0.3% IEEE surge let-through, zero clamping response time, meets UL1449

6.20

5.40

14.10

29

SMT1000 SMT1500 SMT2200

1980 W/2200 VA 2700 W/3000 VA

(8) NEMA 5-15R, (2) NEMA 5-20R

Serial (RJ45), USB and Smart-Slot

Alpha-numeric LCD display with LED status indicators; alarm on battery, distinctive low battery alarm and configurable delays

Optional Yes

8.50

6.70

17.3

42

8.50

6.70

17.3

53

17.0

7.7

21.5

112

UL 1778, FCC Part 15 Class A, CSA

3 years electronics, 2 years battery and $150,000 lifetime EPP

SMT3000

NEMA L5-30P

17.0

7.7

21.5

116

30 | Solutions for network closets and server rooms

Extended run rack/tower convertible models

Product feature

Output

Power capacity

Nominal output voltage

Output frequency

Wave form type

Output connections

Input

Nominal input voltage

Input voltage range for main operations

(Max adjustable range)

Input frequency

Input connection

Batteries and runtime

Battery type

Typical backup time at half load (minutes)

Typical backup time at full Load (minutes)

Replacement battery

External Battery Pack

Communication and management

Interface ports

Control panel and audible alarms

Emergency power off (EPO)

Surge protection and filtering

Surge energy rating

Filtering

Physical

Maximum height (inches)

Maximum width (inches)

Maximum depth (inches)

Net weight (lbs)

Conformance

Regulatory

Warranty and equipment protection policy

SMX750 SMX1000

500 W, 750 VA 800 W, 1000 VA

120 V

57-63Hz

Sine wave

(8) 5-15R, (750 has 1 group, 1000 has 2, 1500 has 3)

1200 W, 1500 VA

120 V

82-143 V (75-153 V)

50/60 Hz +/-3 Hz (auto sensing)

NEMA 5-15P 8 ft cord

3.5 (2U)

17

19

50

SMX1500RM2U

Maintenance-free sealed lead-acid battery with suspended electrolyte, leak proof

24 20 14

12

APCRBC116

8 5

APCRBC115

SMX48RMBP2U

Serial (RJ45), USB and Smart-Slot

Alpha-numeric LCD display with LED status indicators; alarm on battery, distinctive low battery alarm and configurable delays

Yes

645J

Full time multi-pole noise filtering: 0.3% IEEE surge let-through, zero clamping response time, meets UL1449

49

UL 1778, FCC Part 15 Class A, CSA

3 years electronics, 2 years battery and $150,000 lifetime EPP

55

31 | Solutions for network closets and server rooms

Smart-UPS Online

1.5-20 kVA rack/tower convertible 2U-12U

Performance power protection with scalable runtime for spaceconstrained server rooms, and voice and data networks.

APC Smart-UPS Online is a family of high-density, performance UPSs for voice and data networks, server rooms, and light industrial applications. Capable of supporting up to 20 kVA in a 12U rack/tower convertible form, users can support power hungry blade servers or heavily loaded equipment racks. This flexible form factor allows standardization across multiple applications.

Features

• Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

• Scalable runtime Allows quick addition of more runtime when needed.

• Intelligent battery management Provides higher availability through intelligent precision charging that maximizes battery performance, life, and reliability.

• Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment throughout battery replacement.

• Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

• Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

• Flash-upgradeable firmware Allows implementation of new firmware upgrades.

• Network manageable Monitor and control the UPS and access environmental information remotely via included PowerChute software or APC’s Network Management Card with temperature monitoring (included in all models above 3 kVA).

• SmartSlot Customize UPS capabilities with management cards.

• LED status indicators Enables quick understanding and response to visual indicators showing UPS status.

• Serial connectivity Provides management of the UPS via a serial port.

Environments

Network closets: Convergence of voice and data makes availability all the more critical. High power internal chargers allow virtually unlimited additional matching battery packs to comply with aggressive runtime demands of business-critical systems.

Server rooms: Smart-UPS Online small footprint and versatile form factor is very much suitable to enhance availability of the small server rooms drawing single phase power and supporting 5-10 racks worth of IT gear.

Light industrial: The on-line double conversion topology of Smart-UPS Online with input power factor correction is ideal for industrial applications protecting a small control or operations room requiring single phase power. Even the smallest power disruptions can cause work flow disruptions causing thousands and even millions of dollars of damage.

32 | Solutions for network closets and server rooms

Smart-UPS Online specifications

Available models

Smart-UPS Online

1500 VA

Smart-UPS Online

2000 VA

Smart-UPS Online

3000 VA

Smart-UPS Online

5000 VA

Smart-UPS Online

6000 VA

Smart-UPS Online

5000 VA

Smart-UPS Online

6000 VA

Smart-UPS Online

8000 VA

Smart-UPS Online

10000 VA

Smart-UPS Online

15000 VA

Smart-UPS Online

20000 VA

Runtime

(minutes)

22/8

15/5

34/14

18/6

13/4

22/8

15/5

12/4

11/3

16/6

15/5

Watt capacity

1,050

1,400

2,100

6,400

8,000

12,000

16,000

4,000

4,200

3,500

4,200

Input

5-15P

5-20P

L5-30P(120 V),

L6-30P(208 V)

L14-30P

L14-30P

L6-30P

L6-30P

Hardwire (2PH & G)

Hardwire (2PH & G)

Hardwire (2PH & G)

Hardwire (2PH & G)

Output*

(6)5-15

(6)5-15

(6)5-15,

(2)5-20 (120 V),

(2)L6-20,

(2)L6-30 (208 V)

(4)5-20, (2)L6-30,

L14-30

(4)5-20, (2)L6-30,

L14-30

(2)L6-20, L6-30

(2)L6-20, L6-30, (1)

Hardwire (2P & G)

(2)L6-20, (2)L6-30,

(1)Hardwire (2P & G)

(2)L6-20, (2)L6-30,

(1)Hardwire (2P & G)

(2)L6-20, L6-30,

(1)Hardwire (2P & G)

(2)L6-20, L6-30,

(1)Hardwire (2P & G)

Integrated network management card

×

×

×

× x x

×

×

Available optional products

Output stepdown transformer

Output stepdown transformers for use with Smart-UPS Online

3000/5000/6000/8000/10,000 VA models

Steps down 208 V to 120 V

SURT003 Tower stepdown/isolation transformer, rated at 5000 VA, rack-mountable with rail-kit

(SURTRK2), 3U inside rack

AP9626 Rack optimized stepdown transformer, rated at 5000 VA, 2U inside rack

Battery packs

An unlimited number of rack/tower convertible external battery packs can be added to achieve desired levels of runtime. Smart-UPS Online battery packs are hot-swappable so you never have to bring down your mission critical loads to service the unit.

SURT192XLBP battery pack for Smart-UPS Online

3000/5000/6000/8000/10,000 VA models, 3U inside the rack

SURTA48XLBP battery pack for APC Smart-UPS

Online 1500/2000 VA models, 2U inside the rack

Rail kits

AP9625 2-post rail-kit for

Smart-UPS Online

SURTRK 4-post rail-kit for Smart-UPS Online

1500/2000 VA models and SURTA48XLBP

SURTRK2 4-post rail-kit for Smart-UPS Online

3000/5000/6000/8000/10,000 VA models,

SURT192XLBP, SURT003, and AP9626

33 | Solutions for network closets and server rooms

Symmetra

4-16 kVA N+1 redundant, rack or tower

High performance, redundant power protection with scalable power and runtime for space-constrained server rooms, and voice and data networks.

Engineered to deliver the highest level of business continuity possible, the

Symmetra LX uses a modular redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. With built-in network manageability, and rack-optimized and tower models available from 4-16 kVA N+1 redundant, the online Symmetra LX is the choice to protect high-performance IT and Telecom equipment in business-critical server and network rooms.

Environments

Network Closets: Convergence of voice and data makes availability all the more critical. Redundant and manageable power protection provides scalable runtime for network applications in addition to cellular sites, VoIP applications, and PBX systems.

Server Rooms: Symmetra LX provides remote management over the network to manage and maintain unpredictable changes in the environment.

The modular design and N+1 redundancy offers high availability and serviceability.

Retail: Extended power outages can disrupt an entire store, including point of sale terminals, servers, and network switches in the back room. Symmetra

LX allows for un-interruptible operation for business-critical systems.

Light Industrial: The on-line double conversion topology of input power factor correction is ideal for industrial applications protecting a small control.

Even the smallest power disruptions can cause work flow disruptions causing thousands and even millions of dollars of damage.

Features

• Scalable runtime Allows quick addition of more runtime when needed.

• Scalable power Reduces UPS over-sizing costs today by allowing quick upgrades later.

• Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

• Configurable for N+1 internal redundancy

Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

• Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

• Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, hot-swappable, and fieldreplaceable modules.

• Network manageable Provides remote management of the UPS over the network.

• LCD display Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events.

• Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

• Removable input/output wiring tray

Allows quick and easy installation and maintenance of the UPS.

• Field-replaceable power distribution panel Ensures compatibility with equipment that has different plug types

34 | Solutions for network closets and server rooms

Symmetra specifications

Symmetra LX 4 kVA scalable to 8 kVA N+1

Symmetra LX 8 kVA scalable to 16 kVA N+1

Symmetra LX 12 kVA scalable to 16 kVA N+1

Symmetra LX 16 kVA scalable to 16 kVA N+1

Symmetra LX 16 kVA scalable to 16 kVA N+1

Ext. Run Tower

half/full load

(minutes)

16/6

17/6

17/6

17/6

47/20

3200

6400

9600

12800

12800

Input

208/240 V Hardwire

208/240 V Hardwire

208/240 V Hardwire

208/240 V Hardwire

208/240 V Hardwire

Output

4 - 8 kVA (RM)

HW + (2) NEMA L14-

30R and (4) NEMA

L5-20R, (4) L14-30,

(8) L5-20

8 - 16 kVA (RM) HW +(4)

NEMA L14-30R and

(8)NEMA L5-20R

208/240 and

120 V Hardwire

(Tower models)

Integrated network management card

×

×

×

×

×

Additional solutions enhancement options

Battery systems

Additional battery modules or external battery frames can be added to achieve desired levels of runtime.

Symmetra LX battery modules and frames are hotswappable so you never have to bring down your mission critical loads to service the unit.

SYBT5 Battery module for APC Symmetra LX.

SYARMXR9B9, SYAXR9B9, and SYARMXR3B3.

Symmetra LX Extended Run Battery Frames.

Service bypass

Service Bypass Panels featuring quick transfer time and wraparound service bypass.

SBP16KP 200/208/240 V; 100A; MBB; Hardwire input/output

SBP16KRMP4U Input: 208 V, Input connections:

Hard Wire 3-wire (2PH + G), Hard Wire 4-wire

(2PH+N+G), Output: 200 V, 208 V, Output

Connections: NEMA L14-30R L6-30R output

SBP16KRMP4U-HW Input: 208 V, Input Connections:

Hard Wire 3-wire (2PH + G), Hard Wire 4-wire

(2PH+N+G), Output: 120 V, 200 V, 208 V, Output

Connections: Hard Wire 3-wire (2PH + G), Hard Wire

4-wire (2PH + N +G), NEMA L14-30R, NEMA L5-20R

Services

Services to extend the coverage beyond the original factory warranty or on site to diagnose or repair your APC equipment

WEXTWAR1YR-SY-16

1 year extended warranty

WEXTWAR3YR-SY-16 3 year extended warranty

WONSITEBE-SY-16 1 year best endeavor response on-site service for Symmetra

WONSITENBD-SY-16 1 year next business day onsite service for Symmetra

Power distribution

Field replaceable receptacle panels allow direct connection enabling fast installation of new

IT equipment.

SYPD1 Power distribution panel; (1) L14-30, (2) L5-20

SYPD3 208/240 V Backplate kit with (2) L6-20R and

(1) L6-30R

SYPD7 208V/240 V Backplate kit with (3) L6-20R

SYPD11 208/240 V Backplate kit with (2) L6-30R

35 | Solutions for network closets and server rooms

Online resources

Learn more

APC Solutions

Visit http://www.apc.com/site/Solutions/index.

cfm/solutions/server-rooms/

See for myself

NetShelter SX multimedia product demo

Receive a guided tour of the NetShelter SX enclosures—at your convenience. Free online multimedia demo walks you through ease of use, power distribution, cooling, and cable management benefits.

Visit www.apc.com/tours/netsheltersxtour

Additional resources

White Paper #103:

How monitoring systems reduce human error in

Distributed Server rooms and remote wiring closets.

Visit http://www.apc.com/wp?wp=103

White Paper #68:

Cooling strategies for IT wiring closets and small rooms

Visit http://www.apc.com/wp?wp=68

White Paper #69:

Power and cooling for VoIP and IP telephony applications

Visit http://www.apc.com/wp?wp=69

APC Podcast Portal

Visit www.apc.com/podcast

Data Center University ™ online education

Data Center University (DCU) courses offer industryleading education for IT professionals and deliver real-world expertise, where and when you need it.

Visit www.datacenteruniversity.com

To learn more about Schneider Electric solutions visit www.schneider-electric.com

Try our FREE, web-based applications to experiment with virtualization, efficiency, and more at tools.apc.com

Make the most of your energy

SM

APC by Schneider Electric

132 Fairgrounds Road

West Kingston, RI 02892-1517

(800) 788-2208

©2012 Schneider Electric. All Rights Reserved. Schneider Electric, APC, Make the most of your energy, NetShelter, NetBotz, Symmetra, Smart-UPS, StruxureWare, Pelco, InfraStruxure, and Data Center University are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. email: [email protected] • 132 Fairgrounds Road, West Kingston, RI 02892 USA • 998-6403