Electric Tankless and Mini Tank

Hot Water

Heaters

Specification Guide

Effective

April 2015

No.1 US brand of electric tankless water heaters

Contents

Electric Tankless and

Mini Tank Hot Water

Heaters

Specification Guide

Effective

April 2015

Important Things to Note

• Complete submittal packages available for download on eemax.com

• All Eemax “Tankless” units are to be hard-wired to the electrical panel box with their own dedicated breaker.

• Size ALL Eemax Tankless Water

Heaters for required performance,

NOT to the existing electrical wiring available.

• Temperature settings of the unit are a “high limit not-to-exceed” specification. Refer to “Eemax Sizing

Guide” on page 4.

• Booster applications (heater installed on a hot water feed line) MUST have temperature control as indicated by the letter “T” in the suffix of the product number.

• To obtain the shortest time to temp, install unit(s) as close to the point-ofuse as possible.

• Pay attention to the minimum and maximum flow rates.

• CNL SKUs are Canada specific.

• “C” indicates evaluation and compliance to either Underwriters

Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.

Eemax ®

Tepid Water Requirements Fact Sheet

Eemax Sizing Guide – Electric Tankless Water Heaters

SafeAdvantage with PhD Technology

SpecAdvantage with PhD Technology

Accumix

Series 1 - Single point and Flow Controlled

Series 1 - Thermostatic

Mini Tank Water Heaters

HomeAdvantage II - Residential

ProSeries

ProAdvantage

Series Two

Series Two, Residential/Commercial “TC”

Series Two, Commercial “T2”

3

4

5-6

7-8

9-10

11-12

13-14

15-16

17-18

19-20

21-22

23-24

25-26

Series Three

Series Four

Three Phase

De-Ionized

27-28

29-30

31-32

De-Ionized – Stainless Steel Internals – 2.4 to 10 kW 33-34

De-Ionized – Stainless Steel Internals – 15 to 28.5 kW 35-36

De-Ionized – Stainless Steel Internals – 18 to 32 kW 37-38

Series Six* 39-40

Series Twelve*

Accessories and Replacement Parts

41-42

43-44

Terms and Conditions/Warranty Information 45

*Obsolete product listed for reference only.

For additional product specifying needs, contact Eemax Support at (800) 543-6163 or email [email protected].

2 Information and product specifications contained in this document are subject to change without notice.

Tepid Water Requirement Fact Sheet

The American National Standards Institute ANSI Z358.1 requirement for tepid water is 60°F – 100°F for Emergency Eye/Face and Drench Showers. This requirement is a direct response to reduce employers’ liability and increase employee safety. The problem with untempered water is that the minimum recommendation of 15 min to flush hazardous chemicals from contaminated parts of the body is often not met because incoming water temperature can be as low as 35° (2°C). This condition can cause hypothermia and at the very least discourage proper flushing of contaminates.

The Eemax collection of Emergency Eye/Face and Drench Shower on demand electric water heaters are specifically engineered to comply with ANSI Z358.1 requirements.

Preventative over temperature measures have been engineered into all ANSI compliant

Eemax instantaneous water heaters. Sophisticated micro processing thermostats are factory set to a safe 60°F – 90°F. Unique staging of elements only allow power required for the flow needed (combo eye/face drench shower).

The powerful drench shower heater has the capacity to deliver 23 GPM at 80°F outlet temperature safely and reliably with no danger of running out of tepid water.

Legionella bacteria or mycrobacteria growth is substantially reduced with instantaneous water heaters as there is no stored tepid water.

When the heater is not operational there is no consumption of energy, making it the most economical way to comply with ANSI Z358.1 code.

Eemax, the market leader in the manufacturing and engineering of electric instantaneous water heaters, can build a heater to fit your requirements.

Contact Eemax Engineering personnel for assistance in selection of the right heater.

800-543-6163 or visit www.eemax.com.

ANSI Requirements for Emergency Eye Washes and Shower Equipment

Emergency Shower Requirements

1. Shower heads should be not less than 82 in. nor more than 96 in. in height from the surfaces on which the user stands.

2. The spray pattern should have a minimum diameter of 20 in. at 60 in. above the surface on which the user stands. The center of the spray pattern should be located at least 16 in. from any obstruction.

3. Emergency shower heads should be capable of delivering a minimum of 20 GPM of flushing fluid at 30 PSI for a minimum 15 minute period.

4. The valve should be designed so that the flushing fluid flow remains on without requiring the use of the operator’s hands, and it should remain on until intentionally shut off. The valve should go from “off” to “on” in 1 second or less.

5. The pull rod should be located not more than 69 in. above the level on which the user stands.

6. Emergency showers should be in accessible locations that require no more than

10 seconds to reach.

7. Delivered flushing fluid temperature should be tepid.

8. Plumbed emergency showers should be activated weekly to verify proper operation.

Plumbed and Self-Contained Eyewash Unit Requirements

1. Eyewash heads should be not less than 33 in. nor more than 45 in. from the surface on which the user stands and 6 in. minimum from the wall or nearest obstruction.

2. The eyewash unit should provide flushing fluid to both eyes simultaneously, and both nozzles should be protected from airborne contaminants.

3. Plumbed and self-contained eyewash equipment should be capable of delivering flushing fluid to the eyes not less than 0.4 GPM at 30 PSI for 15 minutes.

4. The valve should be designed so that the flow remains on without requiring the use of the operator’s hand, and it should remain on until intentionally shut off. The valve should go from “off” to “on” in 1 second or less.

5. Eyewash units should be in accessible locations that require no more than 10 seconds to reach.

6. Delivered flushing fluid temperature should be tepid.

7. Plumbed eyewashes should be activated weekly to verify proper operation.

Personal Eyewash Equipment Requirements

1. Personal eyewash units should have the capacity to deliver immediate flushing to the eyes without being injurious to the user.

2. When addressing washing of the eyes, training should address holding the eyelids open and rolling the eyeballs so flushing fluid will flow on all surfaces of the eye and under the eyelid.

3. Delivered flushing fluid temperature should be tepid.

4. Personal eyewash units should be inspected annually to assure conformance with

ANSI Z358.1-1998.

Eye/Face Wash Equipment Requirements

1. Eye/face wash heads should be no less than 33 in. and no more than 45 in. from the level on which the user stands and 6 in. minimum from the wall or nearest obstruction.

2. The eye/face unit should provide flushing fluid to both eyes simultaneously, and both nozzles should be protected from airborne contaminants.

3. Plumbed eye/face wash equipment should be capable of delivering flushing fluid to the eyes not less than 3.0 GPM at 30 PSI for 15 minutes.

4. The valve should be designed so that the flow remains on without requiring the use of the operator’s hands, and it should remain on until intentionally shut off.

The valve should go from “off” to “on” in 1 second or less.

5. Eye/face wash units should be in accessible locations that require no more than

10 seconds to reach.

6. Delivered flushing fluid temperature should be tepid.

7. Plumbed eye/face washes should be activated weekly to verify proper operation.

Hand-Held Drench Hose Requirements

1. Drench hoses should be capable of delivering a minimum of 3 GPM of flushing fluid at 30 PSI for a minimum 15 minute period.

2. The valve should go from “off” to “on” in 1 second or less.

3. Delivered flushing fluid temperature should be tepid.

4. Plumbed drench hoses should be activated weekly to verify proper operation.

Combination Unit Requirement

1. Shower heads should be not less than 82 in. nor more than 96 in. in height from the surface on which the user stands. Eye or eye/face wash heads should be not less than 33 in. nor more than 45 in. from the surface on which the user stands and 6 in. minimum from the wall or nearest obstruction.

2. The spray pattern of the shower head should have a minimum diameter of 20 in. at 60 in. above the surface on which the user stands. The center of the spray pattern should be located at least 16 in. from any obstruction.

3. Emergency shower heads should be capable of delivering a minimum of 20 GPM of flushing fluid at 30 PSI for a minimum 15 minute period. Eyewash equipment should be capable of delivering a minimum of 0.4 GPM at 30 PSI for a minimum

15 minute period, and eye/face wash equipment should be capable of delivering a minimum of 3 GPM at 30 PSI for a minimum 15 minute period.

4. The pull road should be located not more than 69 in. above the level on which the user stands.

5. Eye and eye/face wash heads should provide flushing fluid to both eyes simultaneously, and both nozzles should be protected from airborne contaminants.

6. The valves should be designed so that the flow remains on without requiring the use of the operator’s hands, and it should remain on until intentionally shut off.

The valve should go from “off” to “on” in 1 second or less.

7. Combination units should be capable of operating simultaneously and should be positioned so that components may be used simultaneously by the same user.

8. Combination units should be in accessible locations that require no more than 10 seconds to reach.

9. Delivered flushing fluid temperature should be tepid.

10. Plumbed combination units should be activated weekly to verify proper operation.

Information and product specifications contained in this document are subject to change without notice.

3

4

Eemax Sizing Guide

Simple Formula Ensures Proper Size of Electric Tankless Water Heaters

A tankless water heater creates hot water on demand.

You need a proportional amount of energy or (kW) to heat the flow (GPM) needed/required for your applications. The chart below will help you determine the correct electric tankless water heater, based on flow rate (GPM) and temperature rise.

44 kW

41 kW

38 kW

35 kW

32 kW

29 kW

26 kW

23kW

67 kW

64 kW

62 kW

59 kW

56 kW

53 kW

50 kW

47 kW

9 kW

6 kW

3 kW

2 kW

20°F

20 kW

18 kW

15 kW

12 kW

Flow Chart Power Required – kW

9

8

11

10

15

14

13

12

19

18

17

16

23

22

21

20

1

0.5

3

2

5

4

7

6

66 kW

62 kW

57 kW

53 kW

48 kW

44 kW

40 kW

35 kW

101 kW

97 kW

92 kW

88 kW

84 kW

79 kW

75 kW

70 kW

31 kW

26 kW

22 kW

18 kW

13 kW

9 kW

4 kW

2 kW

30°F

73 kW

66 kW

59 kW

51 kW

44 kW

37 kW

29 kW

22 kW

132 kW

125 kW

117 kW

110 kW

103 kW

95 kW

88 kW

81 kW

15 kW

7 kW

4 kW

50°F

82 kW

76 kW

70 kW

64 kW

59 kW

53 kW

50 kW

41 kW

129 kW

123 kW

117 kW

111 kW

105 kW

100 kW

94 kW

88 kW

35 kW

29 kW

23 kW

18 kW

12 kW

6 kW

3 kW

40°F

123 kW

113 kW

103 kW

92 kW

82 kW

72 kW

62 kW

51 kW

41 kW

31 kW

21 kW

10 kW

5 kW

70°F

Rise In Temperature °F

62 kW

53 kW

44 kW

35 kW

26 kW

18 kW

9 kW

4 kW

60°F

132 kW

123 kW

114 kW

105 kW

97 kW

88 kW

79 kW

70 kW

NOTE: For simple calculation, kW reference is based on a 100% heater efficiency. Eemax tankless heaters are 99% efficient. kW req. = GPM x temp rise/6.83

Temp rise = kW x 6.83/GPM

GPM = kW x 6.83/temp rise

129 kW

117 kW

105 kW

94 kW

82 kW

70 kW

59 kW

47 kW

35 kW

23 kW

12 kW

6 kW

80°F

132 kW

119 kW

105 kW

92 kW

79 kW

66 kW

53 kW

40 kW

26 kW

13 kW

7 kW

90°F

132 kW

117 kW

103 kW

88 kW

73 kW

59 kW

44 kW

29 kW

15 kW

7 kW

100°F

129 kW

113 kW

97 kW

81 kW

64 kW

48 kW

32 kW

16 kW

8 kW

110°F

Residential, commercial, safety, and industrial slide rule sizing guides are available by request. Contact Eemax

Support at (800) 543-6163 or email [email protected].

Information and product specifications contained in this document are subject to change without notice.

SafeAdvantage with PhD (Nema 4 Incl.)

For Safety Applications – Eye/Face Wash and Drench Showers

Specifications

Electric Tankless Hot Water Heater

Applications

• Eye/face wash

• Emergency drench showers

• Where tepid water is needed

Performance Features

• Thermo-Optical sensor

• Predictive control algorithm

• Adjustable turn on

• Field programmable & firmware updates

• On board diagnostics with digital LCD display

Optional Features

• N4X (304SS) N4X6 (316SS) enclosures

• Freeze protection for harsh climate, up to -30°F

• Electrical disconnect

• GFCI

• Explosion Proof

U.S. Patent Pending

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Suggested Specification

Tankless water heater shall be an Eemax SafeAdvantage model number AP_________________________.

Factory installation in a ______(N4/N4X/N4x6) enclosure.

Enclosure to be fitted with the following features:

_____ FP Freeze protection (-30F)

_____ EDS Non-fused disconnect

_____ FDS Fused disconnect

_____ EP Explosion proof (C1D2 Groups A, B, C & D)

_____ GFCI True RMS GFCI with digital display and reset

_____ SK 24’’ legs for free standing applications

_____ RD Remote display

_____ SB Siren and Beacon

Tankless water heater must have water connections on the bottom, and be constructed with NSF61 listed materials. Direct heating element to be non-ferrous, cartridge style, designed for field replacement. Tankless water heater to utilize a dual

PID algorithm, actively managing power application to real-time system demand.

Integrated flow meter capable of volumes in excess of 40 GPM drives predictive control algorithm. Water heater must be protected by redundant safeties. Redundant safeties to include thermo mechanical safety switches, infrared element monitoring via thermo optical sensors, and dual temperature monitoring via master control board.

Tankless water heater user interface must have the following capabilities:

• Selectable display including Celsius/Fahrenheit, inlet temperature, outlet temperature, and set point temperature.

• Must be capable of displaying flow rate in gallons per minute or liters per minute.

• Diagnostic features to include error and fault code display.

• Control board must maintain error/fault history of 9 events.

• Capable of factory coded temperature setting (max and min)

• Capable of firmware upgrades via USB port

• Capable of BMS integration

• Available Data logger for monitoring of internal I/O values and 4 external inputs.

• Compliant with ANSI Z358.1 tepid water without additional mixing or purge features

(inlet temperatures must not exceed 100ºF).

24.00

3.50

OUTLET

1 1/4

NPT

11.72

30.00

28.50

INLET

1 1/4

NPT

4XØ .41 THRU

25.25

13.47

6.29

Electrical configuration and requirements

All Eemax three phase units are custom made to order and as such, are nonreturnable and non-refundable. We urge you, therefore, to check your electrical supply, making sure all criteria for operating your Eemax water heater are met.

L1

Eemax 600v, 480v and 208v

Three Phase Units

Delta Configuration

Requires: 3 Lives and 1 Ground (earth)

L2

L3

Information and product specifications contained in this document are subject to change without notice.

5

with PhD Technolog

SafeAdvantage with PhD (Nema 4 Incl.)

For Safety Applications – Eye/Face Wash and Drench Showers

Specifications

Electric Tankless Hot Water Heater

Suffix Definitions

EE Emergency Eyewash. Shipped with max. temp of 90°F. Shipped with display “Locked.”

EFD Emergency Eye, Face & Drench.

Shipped with max. temp of 90°F. Must get software update to change temp.

Shipped with display “Locked.”

PHD Pressure Drop

Flow Rate (GPM)

2

3

8

11

4

6

22

24

27

30

12

15

18

20

33

35

37

40

14

17

22

26

10

13

6

8

Delta PSI

0

0

0

3

4

0

1

30

34

43

NEMA Cabinet Options

Dimensions: 24’’H x 30’’W x 13’.5’D

(Total weight est 150 lbs.)

N4 Waterproof powder coated steel

N4X Waterproof corrosion resistant

304 stainless steel

N4X6 Waterproof corrosion resistant

316 stainless steel

MODEL NUMBER

VOLTS 208 3 ΦD

AP032208 EE N4

AP032208 EE N4X kW BTU

32 109,189

32 109,189

AMPS

PER

PHASE

89

89

AP036208 EE N4

AP036208 EE N4X

36 122,832 100

36 122,832 100

AP041208 EFD N4 41 143,310 112

AP041208 EFD N4X 41 143,310 112

AP054208 EFD N4 54 184,256 150

AP054208 EFD N4X 54 184,256 150

AP064208 EFD N4 64 218,377 178

AP064208 EFD N4X 64 218,377 178

VOLTS 480 3 ΦD

AP036480 EE N4 36 122,837 43

AP036480 EE N4X

AP039480 EE N4

36 122,837

39 133,068

43

47

AP039480 EE N4X

AP048480 EFD N4

39 133,068 47

48 163,783 57.6

AP048480 EFD N4X 48 163,783 57.6

AP054480 EFD N4 54 184,256

AP054480 EFD N4X 54 184,256

AP063480 EFD N4 63 214,956

AP063480 EFD N4X 63 214,956

AP072480 EFD N4 72 245,674

AP072480 EFD N4X 72 245,674

65

65

76

76

87

87

TURN ON

(GPM)

1.0

1.0

1.0

1.0

1.0

1.0

1.5

1.5

2.5

2.5

1.0

1.0

1.0

1.0

1.0

1.0

1.5

1.5

2.5

2.5

2.5

2.5

RECOMMENDED

WIRE SIZE

(90° C/CU)

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

2/0 AWG

2/0 AWG

3/0 AWG

3/0 AWG

8 AWG

8 AWG

6 AWG

6 AWG

6 AWG

6 AWG

4 AWG

4 AWG

3 AWG

3 AWG

3 AWG

3 AWG

3.0

GPM

73°

73°

82°

82°

93°

93°

123°

123°

+

+

82°

82°

89°

89°

109°

109°

123°

123°

143°

143°

+

+

4.0

GPM

55°

55°

61°

61°

70°

70°

92°

92°

109°

109°

61°

61°

67°

67°

82°

82°

92°

92°

108°

108°

123°

123°

5.0

GPM

36°

36°

49°

49°

47°

47°

61°

61°

73°

73°

41°

41°

53°

53°

55°

55°

61°

61°

86°

86°

82°

82°

TEMPERATURE RISE °F

6.0

GPM

29°

29°

41°

41°

37°

37°

49°

49°

58°

58°

33°

33°

44°

44°

44°

44°

49°

49°

72°

72°

66°

66°

20.0

GPM

11°

11°

12°

12°

14°

14°

18°

18°

22°

22°

12°

12°

13°

13°

16°

16°

18°

18°

22°

22°

25°

25°

23.0

GPM

10°

10°

11°

11°

12°

12°

16°

16°

19°

19°

11°

11°

12°

12°

14°

14°

16°

16°

19°

19°

21°

21°

AP096480 EFD N4 96 327,552 116

AP096480 EFD N4X 96 327,552 116

AP108480 EFD N4 108 368,511 130

AP108480 EFD N4X 108 368,511 130

AP126480 EFD N4 126 429,930 151

AP126480 EFD N4X 126 429,930 151

AP144480 EFD N4 144 491,348 173

AP144480 EFD N4X 144 491,348 173

VOLTS 600 3 ΦD

C AP130600 EFD N4 130 443,578 125

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

1/0 AWG

1/0 AWG

1/0 AWG

1/0 AWG

2/0 AWG

2/0 AWG

3/0 AWG

3/0 AWG

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

131°

131°

123°

123°

+

+

+

+

109°

109°

98°

98°

115°

115°

+

+

33°

33°

37°

37°

43°

43°

49°

49°

29°

29°

32°

32°

37°

37°

43°

43°

2.5

1 AWG + + + 118° 44° 29°

C AP130600 EFD N4X 130 443,578 125

C AP150600 EFD N4 150 511,821 144

2.5

2.5

1 AWG

1/0 AWG

+

+

+

+

+

+

118°

+

44°

51°

29°

45°

C AP150600 EFD N4X 150 511,821 144 2.5

1/0 AWG + + + + 51°

+ Temperature electronically limited to factory preset not to exceed temperature.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.

45°

26.0

GPM

34°

34°

39°

39°

25°

25°

28°

28°

17°

17°

19°

19°

33°

33°

38°

38°

13°

13°

14°

14°

10°

10°

14°

14°

17°

17°

11°

11°

30.0

GPM

40.0

GPM

12°

12°

15°

15°

22°

22°

25°

25°

14°

14°

16°

16°

29°

29°

33°

33°

11°

11°

12°

12°

26°

26°

24°

24°

22°

22°

26°

26°

16°

16°

18°

18°

11°

11°

12°

12°

22°

22°

25°

25°

11°

11°

24.00

30.00

28.50

4XØ .41 THRU

25.25

Special Design Service

PURGE

KIT

SIREN/BEACON

30.00

VENT are welcome. Call our Technical Service department at 1-800-543-6163.

41.35

36.00

3.50

11.72

OUTLET 1 1/4 NPT INLET 1 1/4 NPT

13.47

6.29

5.57

OUTLET 1 1/4 NPT INLET 1 1/4 NPT

17.31

1.39

NEMA Cabinet Option Accessories:

Dimensions: 36’’H x 30’’W x 17.3’’D)

(Total weight est. 225 lbs.)

FP Freeze protection (-30°F)

EDS Non-fused disconnect

FDS Fused disconnect

EP Explosion proof (C1D1/2

Groups A,B,C,&D)

24.00

30.00

28.50

4XØ .41 THRU

25.25

SK 24” legs for free standing applications

RD Remote display

11.72

OUTLET 1 1/4 NPT INLET 1 1/4 NPT

SB Siren and Beacon

13.47

6.29

PURGE

KIT

SIREN/BEACON

30.00

41.35

5.57

OUTLET 1 1/4 NPT

VENT

17.31

36.00

30.00

1.39

6 Information and product specifications contained in this document are subject to change without notice.

1.5625 OUTLET

1 1/4 NPT

INLET

1 1/4 NPT

12.8125

30.00

24.00

INLET

1 1/4 NPT

12.8125

SpecAdvantage with PhD

For Commercial and Industrial Applications

Specifications

Electric Tankless Hot Water Heater

Applications

• Eye/face wash

• Emergency drench showers

• Where tepid water is needed

• Booster applications for sanitation

• Commercial kitchen

• Process heating

• High volume domestic hot water

Performance Features

• Thermo-Optical sensor

• Predictive control algorithm

• Adjustable turn on

• Field programmable & firmware updates

• On board diagnostics with digital LCD display

• Designed for commercial and industrial applications

Optional Features

• N4, N4X (304SS) N4X6 (316SS) enclosures

• Freeze protection for harsh climate, up to -30°F

• Electrical disconnect

• GFCI

• Explosion Proof

U.S. Patent Pending

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

26.17

10.28

Suggested Specification

Tankless water heater shall be an Eemax SpecAdvantage model number AP_________________________.

Optional factory installation in a ____(N4/N4X/N4X6) enclosure.

Enclosure to be fitted with the following features:

_____ FP Freeze protection (-30F)

_____ EDS Non-fused disconnect

_____ FDS Fused disconnect

_____ EP Explosion proof (C1D2 Groups A, B, C & D)

_____ GFCI True RMS GFCI with digital display and reset

_____ SK 24’’ legs for free standing applications

_____ RD Remote display

_____ SB Siren and beacon

Tankless water heater must have water connections on the bottom, and be constructed with NSF 61 listed materials. Direct heating element to be non-ferrous, cartridge style, designed for field replacement. Tankless water heater to utilize a dual PID algorithm, actively managing power application to real-time system demand. Integrated flow meter capable of volumes in excess of 40 GPM drives predictive control algorithm.

Water heater must be protected by redundant safeties. Redundant safeties to include thermo mechanical safety switches, infrared element monitoring via thermo optical sensors, and dual temperature monitoring via master control board. Tankless water heater user interface must have the following capabilities:

• Selectable display including Celsius/Fahrenheit, inlet temperature, outlet temperature, flow rate, and set point temperature.

• Must be capable of displaying flow rate in gallons per minute or liters per minute.

• Diagnostic features to include error and fault code display.

• Control board must maintain error/fault history of 9 events.

• Capable of factory coded temperature setting (max and min)

• Capable of firmware upgrades via USB port

• Capable of BMS integration

• Available Data logger for monitoring of internal I/O values and 4 external inputs.

• Compliant with ANSI Z358.1 tepid water without additional mixing or purge features

(inlet temperatures must not exceed 100°F when selecting an EE or EFD option)

1.55

13.31

OUTLET

1 1/4 NPT

INLET

1 1/4 NPT

17.61

L2

L3

5.20

Electrical configuration and requirements

All Eemax three phase units are custom made to order and as such, are nonreturnable and non-refundable. We urge you, therefore, to check your electrical supply, making sure all criteria for operating your Eemax water heater are met.

Eemax 600v, 480v and 208v

Three Phase Units

Delta Configuration

Requires: 3 Lives and 1 Ground (earth)

L1

Information and product specifications contained in this document are subject to change without notice.

7

26.17

1.55

13.31

OUTLET

1 1/4 NPT

INLET

1 1/4 NPT

17.61

5.20

10.28

with PhD Technolog

SpecAdvantage with PhD

For Commercial and Industrial Applications

Specifications

Electric Tankless Hot Water Heater

Suffix Definitions

S Sanitation. Shipped at 180°F with temp range of 100°F-190°F max.

EE Emergency Eyewash. Shipped with max. temp of 90°F. Shipped with display “Locked.”

EFD Emergency Eye, Face & Drench.

Shipped with max. temp of 90°F. Must get software update to change temp.

Shipped with display “Locked.”

PHD Pressure Drop

Flow Rate (GPM)

2

3

8

11

4

6

22

24

27

30

12

15

18

20

33

35

37

40

NEMA Cabinet Options

Dimensions: 24’’H x 30’’W x 13’.5’D

(Total weight est 150 lbs.)

N4 Waterproof powder coated steel

N4X Waterproof corrosion resistant

304 stainless steel

N4X6 Waterproof corrosion resistant

316 stainless steel

24.00

30.00

28.50

3.50

11.72

OUTLET

1 1/4 NPT

INLET

1 1/4 NPT

8

14

17

22

26

10

13

6

8

Delta PSI

0

0

0

3

4

0

1

30

34

43

4XØ .41 THRU

25.25

6.29

13.47

RECOMMENDED

WIRE SIZE

(90° C/CU)

TEMPERATURE RISE °F

MODEL NUMBER

VOLTS 208 3 ΦD

AP032208

AP032208 EE

AP032208 S

AP036208

AP036208 EE

AP036208 S

AP041208

AP041208 EFD

AP041208 S

AP054208

AP054208 EFD

AP054208 S kW

32 109,189

32 109,189

32 109,189

36 122,832

36

36

41

41

BTU

122,832

122,832

143,310

143,310

41 143,310

54 184,256

54 184,256

54 184,256

AMPS

PER

PHASE

89

89

89

100

100

100

112

112

112

150

150

150

TURN ON

(GPM)

1.0*

1.0*

1.0*

1.0*

1.0*

1.0*

1.0*

1.0*

1.0*

1.5*

1.5*

1.5*

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

1 AWG

2/0 AWG

2/0 AWG

2/0 AWG

3.0

GPM

73°

73°

73°

82°

82°

82°

93°

93°

93°

123°

123°

123°

4.0

GPM

55°

55°

55°

61°

61°

61°

70°

70°

70°

92°

92°

92°

5.0

GPM

36°

36°

36°

49°

49°

49°

47°

47°

47°

61°

61°

61°

7.

6.0

GPM

29°

29°

29°

41°

41°

41°

37°

37°

37°

49°

49°

49°

20.0

GPM

11°

11°

11°

12°

12°

12°

14°

14°

14°

18°

18°

18°

23.0

GPM

10°

10°

10°

11°

11°

11°

12°

12°

12°

16°

16°

16°

AP064208

AP064208 EFD

AP064208 S

VOLTS 480 3 ΦD

AP036480

64

64

64

218,377

218,377

218,377

178

178

178

2.5

2.5

2.5

3/0 AWG

3/0 AWG

3/0 AWG

146°

146°

146°

109°

109°

109°

73°

73°

73°

58°

58°

58°

22°

22°

22°

19°

19°

19°

AP036480 EE

AP036480 S

AP039480

AP039480 EE

36 122,837

36

36

39

122,837

122,837

133,068

43

43

43

47

1.0*

1.0*

1.0*

1.0*

8 AWG

8 AWG

8 AWG

6 AWG

82°

82°

82°

89°

61°

61°

61°

67°

41°

41°

41°

53°

33°

33°

33°

44°

12°

12°

12°

13°

11°

11°

11°

12°

AP039480 S

AP048480

AP048480 EFD

AP054480

AP054480 EFD

AP063480

AP063480 EFD

AP063480 S

AP072480

AP072480 EFD

AP096480

AP096480 EFD

AP096480 S

39 133,068

39

48

48

133,068

163,783

163,783

54 184,256

54 184,256

63

63

214,956

214,956

63 214,956

72 245,674

72

96

245,674

327,552

96 327,552

96 327,552

47

47

58

58

65

65

76

76

76

87

87

116

116

116

1.0*

1.0*

1.0*

1.0*

1.5*

1.5*

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

6 AWG

6 AWG

6 AWG

6 AWG

4 AWG

4 AWG

3 AWG

3 AWG

3 AWG

3 AWG

3 AWG

1/0 AWG

1/0 AWG

1/0 AWG

89°

89°

109°

109°

123°

123°

143°

143°

143°

+

+

+

+

+

67°

67°

82°

82°

92°

92°

108°

108°

108°

123°

123°

+

+

+

53°

53°

55°

55°

61°

61°

86°

86°

86°

82°

82°

131°

131°

44°

44°

44°

44°

49°

49°

72°

72°

72°

66°

66°

109°

109°

131° 109°

13°

13°

16°

16°

18°

18°

22°

22°

22°

25°

25°

33°

33°

33°

12°

12°

14°

14°

16°

16°

19°

19°

19°

21°

21°

29°

29°

29°

AP108480 108 368,511 130 2.5

1/0 AWG + + 123° 98° 37° 32°

AP108480 EFD 108 368,511 130 2.5

1/0 AWG + + 123° 98° 37° 32°

AP126480 126 429,930 151 2.5

2/0 AWG + + 143° 115° 43° 37°

AP126480 EFD 126 429,930 151 2.5

2/0 AWG + + 143° 115° 43° 37°

AP144480 144 491,348 173 2.5

3/0 AWG + + + + 49° 43°

AP144480 EFD

VOLTS 600 3 ΦD

C AP130600 EFD

144

130

491,348

443,578

173

125

2.5

2.5

3/0 AWG

1 AWG

+

+

+

+

+

+

+

118°

49°

44°

43°

29°

C AP150600 EFD 150 511,821 144 2.5

1/0 AWG + + + + 51° 45°

* Units with 1 GPM turn-on are limited to 120°F only. Contact Eemax support for applications above 120°F and 1 GPM or less.

+ Temperature electronically limited to factory preset not to exceed temperature.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.

26.0

GPM

34°

39°

14°

14°

14°

17°

11°

11°

11°

17°

17°

17°

19°

19°

25°

14°

14°

17°

17°

10°

10°

13°

13°

10°

33°

33°

38°

38°

25°

25°

28°

28°

30.0

GPM

40.0

GPM

26°

24°

22°

26°

11°

11°

11°

12°

12°

12°

15°

15°

15°

14°

16°

16°

22°

12°

12°

14°

14°

11°

11°

29°

29°

33°

33°

22°

22°

25°

25°

11°

12°

12°

16°

11°

11°

22°

22°

25°

25°

16°

16°

18°

18°

NEMA Cabinet Option Accessories:

Dimensions: 36’’H x 30’’W x 17.3’’D)

(Total weight est. 225 lbs.)

FP Freeze protection (-30°F)

30.00

28.50

EDS Non-fused disconnect

FDS Fused disconnect

EP

SIREN/BEACON VENT

Explosion proof (C1D1/2 Groups A,B,C,&D)

GFCI True RMS GFCI with digital display and reset

4XØ .41 THRU

25.25

SK

RD

24” legs for free standing applications

Remote display

SB Siren and Beacon

OUTLET 1 1/4 NPT INLET 1 1/4 NPT

36.00

13.47

6.29

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at

1.39

1-800-543-6163.

PURGE

KIT

SIREN/BEACON

30.00

41.35

VENT

5.57

OUTLET 1 1/4 NPT INLET 1 1/4 NPT

17.31

36.00

1.39

Information and product specifications contained in this document are subject to change without notice.

30.00

24.00

30.00

24.00

INLET

1 1/4 NPT

12.8125

1.5625 OUTLET

1 1/4 NPT

INLET

1 1/4 NPT

12.8125

AccuMix Series

Ideal for Sensor or Metering Faucets. UPC 413.1 Code Compliant

Performance Features

• Eemax exclusive turnkey solution

• Integrated mixing valve meets ASSE 1070-2004

• Meets UPC 413.1 requirements when properly installed

• No scalding or temperature spikes

• Product performance test indicator light

• 99% energy efficient reducing your utility costs

• On-Demand hot water –– never run out

• 0.3 GPM turn on

• Quick temperature ramp up time

• Compatible with all sensor and non-sensor faucets

• Save water – “Point of Use”

• Easy installation – only one cold or hot water line is needed for installation – integral compression fittings for 1/2” pipe on

BOTTOM (MB Units) or 3/8” on TOP (MT Units)

• Reduces calcification, liming and sedimentation

• Reduces installation cost and material – No T&P relief valve needed (check local codes)

• Warranty – Heaters, against failure due to leaks of “Heater

Body/Element Assembly”, five (5) years – Parts, one (1) year

• High Temperature Limit Switch (ECO) with automatic reset

• ADA Compliant

Product Specifications

Dimensions:

Weight:

Cover:

13.5” H x 5” W x 4” D

8 lbs.

Steel Powder Coated

Color: Sandstone

Temperature:

Element:

MT Fittings:

MB Fittings:

Factory set to 105°F

Replaceable Ni Chrome cartridge insert

3/8” compression fittings at TOP of unit

1/2” compression fittings at BOTTOM of unit

UL Listed: E86887

U.S. Patent Pending Technology

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Tankless water heater shall be an Eemax AccuMix model number M_____________________T.

Tankless Water Heater shall be an Eemax AccuMix model, with digital microprocessing temperature control capable of maintaining outlet temperature of +/–1°F accuracy, and uses an ASSE 1070 approved integrated mixing valve to conform to UPC 413.1.

Element shall be replaceable cartridge insert. Unit shall have replaceable filter in the inlet connector. Element shall be iron free, Nickel Chrome material. Heater shall be fitted with 1/2” pipe compression fittings (5/8” OD) or 3/8” (1/2’’ OD) fittings, to eliminate need for soldering. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

MT Version

3/8” compression fittings at

TOP of unit

Specifications

Electric Tankless Hot Water Heater

MB Version

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

1/2” compression fittings at

BOTTOM of unit

Information and product specifications contained in this document are subject to change without notice.

9

AccuMix Series

Ideal for Sensor or Metering Faucets. UPC 413.1 Code Compliant

Specifications

Electric Tankless Hot Water Heater

Warning: The temperature of this heater has been Eemax factory set at 105°f for hand washing applications and must not be adjusted. Tampering with any adjustments will void warranty and may cause a loss of compliance to Uniform

Plumbing Code 413.1. For further information please contact our technical support department at

1-800-543-6163.

TEMPERATURE RISE °F

MODEL NUMBER VOLTS kW AMPS

ACCUMIX MT with 3/8” Compression Fittings at TOP of Unit

C MT004120T 120V 3.5

29A

TURN

ON

(GPM)

0.3

C MT005240T 240V 4.8

20A

C MT005240T (derated 208V perf.) 240V* 3.6

17A

C MT007240T 240V 6.5

27A

C MT007240T (derated 208V perf.) 240V* 4.9

24A

0.3

0.3

0.3

0.3

C MT010240T 240V 9.5

40A

C MT010240T (derated 208V perf.) 240V* 7 34A

MT004277T

MT008277T

277V

277V

4.1

8.0

14.8A

29A

0.3

0.3

0.3

0.3

MT010277T 277V 10.0

40A 0.3

ACCUMIX MB with 1/2” Compression Fittings at BOTTOM of Unit

C MB004120T

C MB005240T

120V 3.5

29A

240V 4.8

20A

C MB005240T (derated 208V perf.) 240V* 3.6

17A

C MB007240T 240V 6.5

27A

C MB007240T (derated 208V perf.) 240V* 4.9

24A

0.3

0.3

0.3

0.3

0.3

RECOM-

MENDED WIRE

SIZE (CU)

10 AWG

12 AWG

12 AWG

10 AWG

10 AWG

8 AWG

8 AWG

14 AWG

10 AWG

8 AWG

10 AWG

12 AWG

12 AWG

10 AWG

# OF 0.5

AERATORS

SUPPLIED/UNIT

1

1

1

2

2

3

3

1

2

3

1

1

1

2

WATER

CONNECTIONS

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

1/2”

1/2”

1/2”

1/2”

COMPRESSION

FITTINGS

Top

Top

Top

Top

Top

Top

Top

Top

Top

Top

Bottom

Bottom

Bottom

Bottom

0.5

GPM

48°

64°

49°

66°

56°

48°

64°

49°

1.0

GPM

31°

25°

44°

33°

65°

48°

28°

55°

68°

31°

25°

44°

1.5

GPM

21°

16°

30°

22°

43°

32°

19°

36°

46°

21

16°

30°

10 AWG 2 1/2” Bottom 66° 33° 22°

C MB010240T 240V 9.5

40A

C MB010240T (derated 208V perf.) 240V* 7 34A

C MB012240T 240V 11.5

50A

C MB012240T (derated 208V perf.) 240V* 8.7

42A

0.3

0.3

0.3

0.3

8 AWG

8 AWG

6 AWG

6 AWG

3

3

4

4

1/2”

1/2”

1/2”

1/2”

Bottom

Bottom

Bottom

Bottom

65°

48°

79°

43°

32°

52°

59° 39°

MB004277T

MB008277T

277V 4.1

14.8A

277V 8.0

29A

0.3

0.3

14 AWG

10 AWG

1

2

1/2”

1/2”

Bottom

Bottom

56°

28° 19°

55° 36°

MB010277T 277V 10.0

40A 0.3

8 AWG 3 1/2” Bottom † 68° 46°

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 208V to 240V single phase applied voltage. Check with local officials prior to derating the electrical infrastructure.

† Units are factory preset to not exceed 105°F.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.

10

5.16

MT

2.7

5.16

MB

4.10

4.14

2.7

Information and product specifications contained in this document are subject to change without notice.

Point of Use “Non-Thermostatic”

Single Point and Flow Controlled (Designed for cold water feed only)

Applications

• Hand washing (0.35-2.0 GPM)

• Kitchen/bar/utility sinks

• Manufacturing facilities

• Public hand washing

• Hand set shower (0.7-2.0 GPM)

• Dual handwash sinks (DL option)

• Modular buildings and tenant spaces

Performance Features

• On demand hot water. Flow switch activates heater only on demand (no standby heat loss). 99% efficient

• Endless hot water – no storage capacity to run out

• Easy installation. No T&P relief valve needed (check local codes). Only one cold water line need be brought to installation, mounts on wall

• High temperature limit switch with automatic reset

• Optional flow restricting aerator (for EX-DL models) ensures proper temperature rise. Standard with SP models

• Prevents Legionella bacteria growth

• Reduces calcification, liming and sedimentation

• Complies with handicap ADA physical installation requirements

• Ni Chrome element – a unique, patented flow path ensures optimum heat transfer and extended element life

• Warranty – Heaters, against failure due to leaks of “Heater

Body/Element Assembly”, five (5) years – Parts, one (1) year

Product Specifications

Dimensions: 10.75” x 5.25” x 2.78”

Weight:

Cover:

4 lbs.

ABS UL rated 94Vo.

Color: White

Element: Replaceable cartridge insert

Fittings:

Operating Pressure:

UL Listed:

SP – 3/8” compression fitting at top of unit

EX – 1/2” (5/8” OD) compression fitting at bottom of unit

Min. 25 PSI, max. 150 PSI

E86887 (M)

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Pictured, EX: Bottom Water Connections

U.S. Patent #’s: 4,762,980 and 4,960,976

Specifications

Electric Tankless Hot Water Heater

SP Version

3/8” compression fittings at TOP of unit

EX Version

1/2” compression fittings at

BOTTOM of unit

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Suggested Specification

Tankless water heater shall be an Eemax Non-Thermostatic model number ___________.

Unit shall have ABS-UL 94V0 rated cover. Element shall be replaceable cartridge insert.

Unit shall have replaceable filter in the inlet connector. Element shall be iron free, nickel chrome material. Heater shall be fitted with compression fitting, 1/2” (5/8”OD) for model EX, or 3/8’’ fitting (1/2’’ OD) for model SP, to eliminate need for soldering.

Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal. NOTE: Refer to rating chart for product information.

Specification options available on EX models:

_____ DL Dual Lavs- supplied with two faucet aerators

_____ SL Single Lav – supplied with 3/8’’ compression fittings (0.5 or 1.0 GPM aerator included).

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

11

Point of Use “Non-Thermostatic”

Single Point and Flow Controlled (Designed for cold water feed only)

Specifications

Electric Tankless Hot Water Heater

MODEL NUMBER

VOLTS 120

C SP2412 †

C EX2412 kW

2.4kW

2.4kW

AMPS

20A

20A

C SP3012 †

C EX3012

C SP3512 †

C EX3512

VOLTS 208 Single Phase

C SP3208 †

C EX3208

C SP4208 †

C EX4208

C SP8208 †

C SP8208 DL †

C EX8208

C EX8208 DL

VOLTS 240 *

C SP35 †

3.0kW

3.0kW

3.5kW

3.5kW

3.0kW

3.0kW

4.1kW

4.1kW

8.3kW

8.3kW

8.3kW

8.3kW

3.5kW

25A

25A

29A

29A

15A

15A

20A

20A

40A

40A

40A

40A

15A

C SP35 † (derated 208V perf.) 2.7kW

13A

C EX35 3.5kW

15A

C EX35 (derated 208V perf.) 2.7kW

13A

C EX35 SL 3.5kW

15A

C SP48 † 4.8kW

20A

C SP48 † (derated 208V perf.) 3.6kW

17A

C SP48 DL

C EX48

4.8kW

20A

4.8kW

20A

C EX48 (derated 208V perf.) 3.6kW

17A

C EX48 SL 4.8kW

20A

C EX48 DL

C SP55 †

4.8kW

20A

5.5kW

23A

C SP55 † (derated 208V perf.) 4.1kW

20A

C SP55 DL † 5.5kW

23A

C EX55 5.5kW

23A

C EX55 (derated 208V perf.) 4.1kW

20A

C EX55 DL

C EX55 SL

5.5kW

23A

5.5kW

23A

C SP65 † 6.5kW

27A

C SP65 † (derated 208V perf.) 4.9kW

24A

C SP65 DL

C EX65

† 6.5kW

27A

6.5kW

27A

C EX65 (derated 208V perf.) 4.9kW

24A

C EX65 DL 6.5kW

27A

C EX65 SL

C SP75 †

6.5kW

27A

7.5kW

32A

C SP75 † (derated 208V perf.) 5.6kW

27A

C SP75 DL † 7.5kW

32A

C EX75 7.5kW

32A

C EX75 (derated 208V perf.) 5.6kW

27A

C EX75 DL

C EX75 SL

7.5kW

32A

7.5kW

32A

9.5kW

40A C SP95 †

C SP95 † (derated 208V perf.)

C SP95 DL †

C EX95

7kW

9.5kW

9.5kW

34A

40A

40A

C EX95 (derated 208V perf.)

C EX95 DL

C EX95 SL

7kW

9.5kW

9.5kW

34A

40A

40A

TURN ON

(GPM)

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.5

0.5

0.5

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.3

0.5

0.5

0.5

0.3

0.3

0.3

0.3

RECOMMENDED

WIRE SIZE (CU)

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

10 AWG

14 AWG

14 AWG

12 AWG

12 AWG

8 AWG

8 AWG

8 AWG

8 AWG

10 AWG

10 AWG

8 AWG

*

8 AWG

8 AWG

*

8 AWG

*

10 AWG

10 AWG

10 AWG

*

10 AWG

10 AWG

*

8 AWG

8 AWG

*

8 AWG

8 AWG

*

8 AWG

8 AWG

12 AWG

*

12 AWG

12 AWG

10 AWG

*

10 AWG

10 AWG

14 AWG

*

14 AWG

*

14 AWG

12 AWG

*

12 AWG

TEMPERATURE RISE °F

0.5

GPM

33°

33°

41°

41°

48°

48°

41°

41°

56°

56°

0.75

GPM

1.0

GPM

1.5

GPM

48° 32° 24° 16°

37° 24° 18° 15°

48° 32° 24° 16°

37° 24° 18° 15°

48° 32° 24° 16°

64° 42° 31° 21°

49° 33° 25° 16°

64° 42° 31° 21°

64° 42° 31° 21°

49° 33° 25° 16°

64° 42° 31° 21°

64° 42° 31° 21°

75° 50° 38° 25°

56° 38° 28° 19°

75° 50° 38° 25°

75° 50° 38° 25°

56° 38° 28° 19°

75° 50° 38° 25°

75° 50° 38° 25°

– 59° 44° 30°

66° 44° 33° 22°

– 59° 44° 30°

– 59° 44° 30°

66° 44° 33° 22°

– 59° 44° 30°

– 59° 44° 30°

– 68° 51° 34°

77° 51° 38° 26°

– 68° 51° 34°

– 68° 51° 34°

77° 51° 38° 26°

– 68° 51° 34°

– 68° 51° 34°

– 87° 65° 43°

95° 64° 48° 32°

– 87° 65° 43°

– 87° 65° 43°

95° 64° 48° 32°

– 87° 65° 43°

– 87° 65° 43°

– 76° 57° 38°

– 76° 57° 38°

– 76° 57° 38°

– 76° 57° 38°

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check

† with local officials prior to derating the electrical infrastructure.

3/8” compression fittings at top of unit

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/

CSA-C22.2 No. 64/No. 88.

EX80 DL

SP90 †

SP90 DL †

EX90

EX90 SL

EX90 DL

SP100 †

SP100 DL †

EX100

EX100 SL

EX100 DL

SP60 DL †

EX60

EX60 SL

EX60 DL

SP80 †

SP80 DL †

EX80

EX80 SL

MODEL NUMBER

VOLTS 277

SP3277 †

EX3277

SP4277 †

EX4277

SP60 †

Suffix Definitions

DL Dual Lavs – Two faucet aerators provided

SL Single Lav – 3/8” compression connections

“EX”

9.67

1.11

OUTLET

1.50

INLET

“SP”

9.67

OUTLET

1.50

5.22

5.22

kW AMPS

TURN ON

(GPM)

RECOMMENDED

WIRE SIZE (CU)

TEMPERATURE RISE °F

0.5

GPM

0.75

GPM

1.0

GPM

1.5

GPM

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.3

0.3

0.3

0.3

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

9.0kW

9.0kW

9.0kW

10kW

10kW

10kW

10kW

10kW

6.0kW

8.0kW

8.0kW

8.0kW

8.0kW

8.0kW

9.0kW

9.0kW

3.0kW

3.0kW

11A

11A

4.1kW

14.8A

4.1kW

14.8A

6.0kW

6.0kW

6.0kW

6.0kW

22A

22A

22A

22A

29A

29A

33A

33A

22A

29A

29A

29A

36A

36A

36A

36A

33A

33A

33A

36A

14 AWG

14 AWG

14 AWG

14 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

41°

41°

56° 37° 28° 19°

56° 37° 28° 19°

– 55° 41° 27°

– 55° 41° 27°

– 55° 41° 27°

– 55° 41° 27°

– 55° 41° 27°

– 73° 55° 36°

– 73° 55° 36°

– 73° 55° 36°

– 73° 55° 36°

– 73° 55° 36°

– 82° 61° 41°

– 82° 61° 41°

– 82° 61° 41°

– 82° 61° 41°

– 82° 61° 41°

– 91° 68° 46°

– 91° 68° 46°

– 91° 68° 46°

– 91° 68° 46°

– 91° 68° 46°

3.00

.81

INLET

1.11

.81

3.00

NEMA 4/4X

For EX version only. NEMA cabinets not available for SP version.

11.08

11.81

5.91

1.07

9.84

7.30

4X Ø.25

MOUNTING

HOLES

OUTLET INLET

4.17 1.50

12 Information and product specifications contained in this document are subject to change without notice.

OUTLET

1 1/2”

INLET

3/4”

10 3/4” 9 3/4”

5 1/4” 2 7/8”

10 3/4” 9 3/4”

5 1/4” 2 7/8”

OUTLET

1 1/2”

INLET

3/4”

Point of Use “Thermostatic”

Micro Processing Temperature Control

Specifications

Electric Tankless Hot Water Heater

Applications

• Multi lav configurations (up to three) ideal for sensor or metering faucets (ML option)

• Emergency eye wash fountains (EE option)

• Dishwashers, commercial kitchens

• Low volume showers

Performance Features

• Cut energy waste. Flow switch activates heater only on demand (no standby heat loss) – 99% efficient

• Save Water – “Point of Use”

• Eliminate costly mixing valves (check local codes)

• Continuous hot water. No storage capacity to run out

• Eliminate lag time in long pipe runs

• Booster up to 180°F (S option)

• Easy installation. Only one cold or hot water line need be brought to installation – integral compression fittings for 1/2” pipe (5/8” OD) on bottom (no sweat connections)

• Microprocessor temperature control for thermostatic accuracy +/-1°F. Fully adjustable temperature range between

100-140°. Special settings of higher or lower range available upon request. (see Specification Options)

• Reduces installation cost and materials. No T&P relief valve needed (check local codes)

• Prevents Legionella bacteria growth

• Reduces calcification, liming and sedimentation

• Compact size

• Warranty – Heaters, against failure due to leaks of “Heater

Body/Element Assembly”, five (5) years – Parts, one (1) year

• High temperature limit switch (ECO)

Product Specifications

Dimensions:

Weight:

Cover:

10.75”x 5.25”x 2.875”

4 lbs.

ABS UL rated 94Vo.

Color: White

Std. Temp. Range 100°F-140°F

Element:

Fittings:

UL Listed:

Replaceable Ni Chrome cartridge insert

1/2” pipe compression fittings at bottom of unit. (5/8” OD)

E86887 (M)

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Suggested Specification

Tankless water heater shall be an Eemax Thermostatic model number EX___________.

Unit shall have ABS-UL 94Vo rated cover. Element shall be replaceable cartridge insert.

Unit shall have replaceable filter in the inlet connector. Element shall be iron free,

Nickel Chrome material. Heater shall be fitted with 1/2” pipe compression nuts (5/8”

OD) to eliminate need for soldering. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

Specification options to be included with EX models:

_____ EE Emergency Eyewash. Meets ANSI tepid water requirements. Max. temperature 90°F

_____ FS Factory Set. Customer specified factory-set not to exceed temperature ambient to 180°F

_____ ML Multiple Lavatory. Factory preset to 110°F with

0.3 GPM turn on for sensor and metering faucets

_____ S Sanitation. Factory preset not to exceed temperature of 180°F

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

13

Point of Use “Thermostatic”

Micro Processing Temperature Control

Specifications

Electric Tankless Hot Water Heater

MODEL NUMBER

VOLTS 120

C EX2412T

C EX2412T EE

C EX2412T FS

C EX2412T S

C EX3012T kW

2.4kW

2.4kW

2.4kW

2.4kW

AMPS

20A

20A

20A

20A

TURN

ON

(GPM)

0.3

0.3

0.3

0.3

REC’D

WIRE SIZE

(CU)

12 AWG

12 AWG

12 AWG

12 AWG

0.5

GPM

33°

33°

33°

33°

TEMPERATURE RISE °F

0.75

GPM

22°

22°

22°

22°

1.0

GPM

1.5

GPM

16° 11°

16° 11°

16° 11°

16° 11°

2.0

GPM

3.0kW

25A 0.3

10 AWG 41° 27° 20° 14° 10°

C EX3012T EE

C EX3012T FS

C EX3012T S

C EX3512 T

C EX3512 T EE

C EX3512 T FS

C EX3512 T ML

C EX3512 T S

VOLTS 240*

C EX35T

C EX35T (derated 208V perf.)

C EX35T EE

C EX35T FS

C EX35T ML

C EX35T S

C EX48T

C EX48T (derated 208V perf.)

C EX48T EE

C EX48T FS

C EX48T ML

C EX48T S

C EX55T

C EX55T (derated 208V perf.)

C EX55T EE

C EX55T FS

C EX55T ML

C EX55T S

C EX65T

C EX65T (derated 208V perf.)

C EX65T EE

C EX65T FS

C EX65T ML

3.0kW

3.0kW

3.0kW

3.5kW

3.5kW

3.5kW

3.5kW

3.5kW

3.5kW

2.7kW

3.5kW

3.5kW

3.5kW

3.5kW

4.8kW

3.6kW

4.8kW

4.8kW

4.8kW

4.8kW

5.5kW

4.1kW

5.5kW

5.5kW

5.5kW

5.5kW

6.5kW

4.9kW

6.5kW

6.5kW

6.5kW

25A

25A

25A

29A

29A

29A

29A

29A

15A

13A

15A

15A

15A

15A

20A

17A

20A

20A

20A

20A

23A

20A

23A

23A

23A

23A

27A

24A

27A

27A

27A

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.7

0.7

0.7

0.7

0.3

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

14 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

12 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

41°

41°

41°

48°

48°

48°

48°

48°

48°

37°

48°

48°

48°

48°

64°

49°

64°

64°

64°

64°

75°

56°

75°

75°

75°

75°

+

27°

27°

27°

32°

32°

32°

32°

32°

32°

24°

32°

32°

32°

32°

42°

33°

42°

42°

42°

42°

50°

38°

50°

50°

50°

50°

59°

44°

59°

59°

59°

20° 14° 10°

20° 14° 10°

20° 14° 10°

24° 16° 12°

24° 16° 12°

24° 16° 12°

24° 16° 12°

24° 16° 12°

24° 16° 12°

18° 1.5° 9°

24° 16° 12°

24° 16° 12°

24° 16° 12°

24° 16° 12°

31° 21° 16°

25° 16° 12°

31° 21° 16°

31° 21° 16°

31° 21° 16°

31° 21° 16°

38° 25° 19°

28° 19° 17°

38° 25° 19°

38° 25° 19°

38° 25° 19°

38° 25° 19°

44° 30° 22°

33° 22° 17°

44° 30° 22°

44° 30° 22°

44° 30° 22°

C EX65T S

C EX75T

C EX75T (derated 208V perf.)

C EX75T EE

C EX75T FS

C EX75T ML

C EX75T S

C EX95T

6.5kW

7.5kW

5.6kW

7.5kW

7.5kW

7.5kW

7.5kW

9.5kW

27A

32A

27A

32A

32A

32A

32A

40A

0.7

0.7

0.7

0.7

0.7

0.3

0.7

0.7

C EX95T (derated 208V perf.)

C EX95T EE

C EX95T FS

C EX95T ML

7kW

9.5kW

9.5kW

9.5kW

34A

40A

40A

40A

0.7

0.7

0.7

0.3

C EX95T S

EX012240T

EX012240T (derated 208V perf.) 8.7kW

EX012240T EE 11.5kW

42A

48A

0.7

0.7

EX012240T FS

EX012240T ML

9.5kW

11.5kW

11.5kW

48A 0.7

11.5kW

40A

48A

48A

0.7

0.7

0.3

EX012240T S 11.5kW

48A 0.7

10 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

+

59°

68°

51°

68°

68°

68°

68°

87°

64°

87°

87°

87°

87°

44° 30° 22°

51° 34° 26°

38° 26° 19°

51° 34° 26°

51° 34° 26°

51° 34° 26°

51° 34° 26°

65° 43° 32°

48° 32° 24°

65° 43° 32°

65° 43° 32°

65° 43° 32°

65° 43° 32°

104° 79° 52° 39°

79° 59° 39° 30°

104° 79° 52° 39°

104° 79° 52° 39°

104° 79° 52° 39°

104° 79° 52° 39°

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage.

Check with local officials prior to derating the electrical infrastructure.

+Temperature electronically limited to factory preset not to exceed temperature.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under

CAN/CSA-C22.2 No. 64/No. 88.

14

MODEL NUMBER

VOLTS 208 Single Phase

C EX3208T

C EX3208T ML

C EX4208T

C EX4208T EE

C EX4208T FS

C EX4208T ML

C EX4208T S

C EX8208T

C EX8208T EE

C EX8208T FS

C EX8208T ML

C EX8208T S

VOLTS 277

EX3277T

EX3277T EE

EX3277T FS

EX3277T ML

EX3277T S

EX4277T

EX4277T EE

EX4277T FS

EX4277T ML

EX4277T S

EX60T

EX60T EE

EX60T FS

EX60T ML

EX60T S

EX80T

EX80T EE

EX80T FS

EX80T ML

EX80T S

EX90T

EX90T EE

EX90T FS

EX90T ML

EX90T S

EX100T

EX100T EE

EX100T FS

EX100T ML

EX100T S

Suffix Definitions kW AMPS

TURN

ON

(GPM)

REC’D

WIRE

SIZE (CU)

0.5

GPM

0.75

GPM

1.0

GPM

1.5

GPM

2.0

GPM

3.0kW

15A 0.3

14 AWG 41° –

3.0kW

15A 0.3

14 AWG 41° –

4.1kW

20A 0.3

12 AWG 56° 37° 28° 18° 14°

4.1kW

20A 0.3

12 AWG 56° 37° 28° 18° 14°

4.1kW

20A 0.3

12 AWG 56° 37° 28° 18° 14°

4.1kW

20A 0.3

12 AWG 56° 37° 28° 18° 14°

4.1kW

20A 0.3

12 AWG 56° 37° 28° 18° 14°

8.3kW

40A 0.7

8 AWG – 76° 57° 38° 28°

8.3kW

40A 0.7

8.3kW

40A 0.7

8.3kW

40A 0.3

8.3kW

40A 0.7

3.0kW

11A 0.3

14 AWG 41° –

3.0kW

11A 0.3

14 AWG 41° –

3.0kW

11A 0.3

14 AWG 41° –

3.0kW

11A 0.3

14 AWG 41° –

3.0kW

11A 0.3

14 AWG 41° – – – –

4.1kW 14.8A

0.3

14 AWG 56° 37° 28° 19° 14°

4.1kW 14.8A

0.3

14 AWG 56° 37° 28° 19° 14°

4.1kW 14.8A

0.3

14 AWG 56° 37° 28° 19° 14°

4.1kW 14.8A

0.3

14 AWG 56° 37° 28° 19° 14°

4.1kW 14.8A

0.3

14 AWG 56° 37° 28° 19° 14°

6.0kW

22A 0.7

10 AWG – 55° 41° 27° 20°

6.0kW

22A 0.7

10 AWG – 55° 41° 27° 20°

6.0kW

22A 0.7

10 AWG – 55° 41° 27° 20°

6.0kW

22A 0.3

10 AWG 81° 55° 41° 27° 20°

6.0kW

22A 0.7

10 AWG – 55° 41° 27° 20°

8.0kW

29A 0.7

10 AWG – 73° 55° 36° 27°

8.0kW

29A 0.7

10 AWG – 73° 55° 36° 27°

8.0kW

29A 0.7

10 AWG – 73° 55° 36° 27°

8.0kW

29A 0.3

10 AWG + 73° 55° 36° 27°

8.0kW

29A 0.7

10 AWG – 73° 55° 36° 27°

9.0kW

33A 0.7

9.0kW

33A 0.7

9.0kW

33A 0.7

9.0kW

33A 0.3

9.0kW

33A 0.7

10.0kW

36A 0.7

10.0kW

36A 0.7

10.0kW

36A 0.7

10.0kW

36A 0.3

10.0kW

36A 0.7

EE Meets ANSI Z358.1 emergency eye/face wash tepid water requirements

FS Factory set ambient to 180°

ML Multi lavs 0.3 turn on. staged up to

S

4 lavs 105°-110° temp setting

Sanitation 180°

5.22

3.00

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

NEMA

4/4X

8 AWG

8 AWG

8 AWG

8 AWG

11.08

11.81

– 76° 57° 38° 28°

– 76° 57° 38° 28°

+ 76° 57° 38° 28°

– 76° 57° 38° 28°

+

+

TEMPERATURE RISE °F

82°

82°

82°

82°

82°

91°

91°

91°

91°

91°

61° 41° 31°

61° 41° 31°

61° 41° 31°

61° 41° 31°

61° 41° 31°

68° 46° 34°

68° 46° 34°

68° 46° 34°

68° 46° 34°

68° 46° 34°

7.30

9.84

4X Ø.25

MOUNTING

HOLES

9.67

5.91

OUTLET INLET

1.11

OUTLET

1.50

INLET

.81

1.07 4.17 1.50

Information and product specifications contained in this document are subject to change without notice.

85% reduction

Mini-Tank Series

1.5, 2.5, 4 and 6 Gallon Mini Tanks Deliver Hot Water Efficiently

Specifications

Electric Mini-Tank Hot Water Heater

Performance Features

• Point-of-use heating eliminates long hot water pipe runs

• Compact design fits virtually anywhere

• Easy and ready to install

• Hot or cold water feed

• Adjustable temperature control 50°-140°F

• T&P relief valve included

• Glass lined tank for extended life

• Floor and wall mountable, bracket included

• Field replaceable element

• ETL tested to UL174 and NSF372

• EMT1, EMT2.5 and EMT4 plug into standard outlets, cord included. EMT6 must be hard wired, pig tail included

• Single weld design

• Tank status indicator light –

Green: ready mode

Red: heating mode

• Warranty, five (5) years limited on leaks, two (2) years on defects

Product Specifications

• Voltage: 120 volts

• Amperage: 12 amps

• Heating Capacity: 1440 watts

• Phase: Single

• Temperatures: 50°-140°F

• Max. Operating Pressure: 150 PSI

Tank

Volume Weight

(gals) (lbs.) Fittings

EMT1 1.5

EMT2.5 2.5

EMT4 4

EMT6 6

Recovery time based on 60° temp. rise

11.7 1/2” NPT connections at TOP of unit 8 minutes

15.5 1/2” NPT connections at TOP of unit 15 minutes

19.3 1/2” NPT connections at TOP of unit 24 minutes

24.9 3/4” NPT connections at TOP of unit 37 minutes

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Water heater shall be an Eemax Mini-Tank model number

EMT______.

Unit shall be glass lined with a single weld design. Water connections and supplied

T&P valve to be located on top of the unit. Unit shall have an status indicator light with adjustable thermostat. Unit to have a 5 year warranty against leaks.

F

E

EMT1

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

C

D

H

EMT4

B

EMT2.5

A

G

EMT6

Key inch mm inch mm inch mm inch mm

A 9.95 252.7 11.23 285.2 12.88 327.2 14.36 364.7

B 3.15 80.0 3.13 79.5 4.06 103.1 3.46 87.9

C 9.71 246.6 10.89 276.6 12.27 311.7 13.85 351.8

D

E

3.94 100.1 3.94 100.1

5.08 129.0 5.61 142.5

3.94 100.1

6.46 164.1

3.94 100.1

7.52 191.0

F 15.09 383.3 16.91 429.5 18.27 464.1 20.96 532.4

G 14.19 360.4 15.98 405.9 17.41 442.2 19.81

H* 2.52 64.0 2.52 64.0 2.52 64.0 2.52 64.0

*Mounting bracket location on the back of unit

Information and product specifications contained in this document are subject to change without notice.

15

Mini-Tank Series

1.5, 2.5, 4 and 6 Gallon Mini Tanks Deliver Hot Water Efficiently

Specifications

Electric Mini-Tank Hot Water Heater

Eemax Mini Tank

Installation

Save water by eliminating the wait for hot water to reach the faucet. Simply tap into the water line and install the heater directly at the sink.

No need for costly recirculating lines and pumps. And when you want to eliminate the wait for hot water but need more volume, install the Eemax heater in-line with a larger hot water source, such as a tankless heater or a storage tank heater. Lightweight and compact.

MODEL NUMBER

VOLTS 120

C EMT1 kW

TANK

VOLUME DIMENSIONS

WATER

CONNECTIONS

RELIEF

VALVE

1.4

1.5 gallons 12.5” H x 11” W x 10” D 1/2” NPT Included

C EMT2.5

C EMT4

1.4

1.4

2.5 gallons 14.5” H x 11.75” W x 10.375” D

4.0 gallons 19.25” H x 11.75” W x 10.375” D

1/2” NPT

1/2” NPT

Included

Included

C EMT6 1.4

6.0 gallons 18” H x 15.75” W x 15.5” D 3/4” NPT

“C” indicates evaluation and compliance to Intertek (ETL) under CAN/CSA-C22.2 No. 10. *Pigtail included.

Included

Sample Installations

Standalone Point-of-Use Heating Application

COLD WATER FEED

EEMAX EMT ELECTRIC

HOT WATER MINI TANK

ELECTRICAL FEED

SHIPPING

WEIGHT PLUG IN

12.5 lbs.

20 lbs.

24 lbs.

26 lbs.

Yes

Yes

Yes

No*

Standalone Point-of-Use Multi fixture Application

HOT WATER FEED

EEMAX EMT ELECTRIC

HOT WATER MINI TANK

ELECTRICAL FEED

COLD

WATER

FEED

Point-of-Use Booster Heating Application from Central Tank Heating System

COLD

WATER

FEED

HOT WATER OUTLET

EEMAX EMT

ELECTRIC HOT

WATER MINI TANK

ELECTRICAL

FEED

GAS OR

ELECTRIC

WATER

HEATER

Cure for “Cold Water Sandwich” Gas Tankless Heating Application

COLD

WATER

FEED

GAS

TANKLESS

WATER

HEATER

HOT WATER TO FIXTURE

EEMAX EMT ELECTRIC

HOT WATER MINI TANK

ELECTRICAL FEED

HOT WATER OUTLET

COLD

WATER

FEED

16 Information and product specifications contained in this document are subject to change without notice.

HomeAdvantage II

For Single Point-of-Use or Multiple Applications

Applications

• Water-Saver Shower Head 1.5 GPM

• Standard Shower Head 2.0 GPM

• Standard Hand Sink

• Kitchen Sink

• Bath Tub

0.5 GPM

1 to 2 GPM

• Dishwasher

• Washing Machine

≥ 4 GPM

1 to 2 GPM

1 to 1.5 GPM

Average Gallons Per Minute (GPM) based on 2010 Plumbing Standards

Performance Features

• Instant, consistent and endless hot water

• Compact, resistant and stylish with digital temperature control in increments of 1°F ranging from 80°F to 140°F

• 99.8% energy efficient

• Copper immersion heating elements with brass top increases durability and are threaded for easy replacement

• Simple Installation

• Digital temperature display

• External controls to adjust temperature in increments of 1°F.

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Tankless water heater shall be an Eemax HomeAdvantage II model number HA_______________.

HA008240/HA011240/HA013240

HA024240/HA027240

Specifications

Electric Tankless Hot Water Heater

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

HA018240

HA036240

Information and product specifications contained in this document are subject to change without notice.

17

HomeAdvantage II

For Single Point-of-Use or Multiple Applications

Specifications

Electric Tankless Hot Water Heater

MODEL NUMBER kW AMPS

240V* 1 MODULES

C HA008240 8.0 33(1x40)A

C HA008240 (derated 208V performance) 5.8

28A

C HA011240 11.0 46(1x50)A

C HA011240 (derated 208V performance) 8.2

29A

C HA013240 13.0 54(1x60)A

C HA013240 (derated 208V performance) 10.1 49(1x60)A

240V* 2 MODULES

C HA018240 18.0 75(2x38)A

C HA018240 (derated 208V performance) 13.3 64(2x32)A

240V* 3 MODULES

C HA024240 24.0 100(3x33)A

C HA024240 (derated 208V performance) 17.5 84(3x28)A

C HA027240 27.0 112(3x37)A

C HA027240 (derated 208V performance) 20 96(3x32)A

240V* 4 MODULES

C HA036240 36.0 150(4x38)A

C HA036240 (derated 208V performance) 26.6 127(4x32)A

RECOMMENDED

WIRE SIZE (CU)

TURN ON

(GPM)

8 AWG

*

6 AWG

*

6 AWG

*

8 AWG

*

8 AWG

*

8 AWG

*

8 AWG

*

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

MIN.

FLOW

(GPM)

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

MAX.

FLOW

(GPM)

7.0

7.0

8.0

8.0

4.8

4.8

4.8

4.8

4.8

4.8

7.0

7.0

7.0

7.0

1.0

GPM

1.5

GPM

2.0

GPM

TEMPERATURE RISE °F

2.5

GPM

3.0

GPM

4.0

GPM

55°

40°

75°

56°

89°

69°

+

90°

+

+

+

+

+

+

36°

27°

50°

37°

59°

46°

82°

60°

+

+

+

+

+

+

27°

20°

38°

28°

44°

34°

62°

45°

82°

60°

92°

68°

+

91

22°

30°

36°

49°

36°

66°

48°

74°

55°

98°

73°

18°

25°

30°

41°

30°

55°

40°

62°

45°

82°

61°

22°

31°

41°

30°

46°

34°

62°

45°

5.0

GPM

6.0

GPM

25°

33°

24°

37°

27°

49°

36°

41°

30°

27°

20°

31°

23°

* 240V units can be used on

208V single phase with 25% reduced temperature output.

Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage.

Check with local officials prior to derating the electrical infrastructure.

+ Temperature electronically limited setting on adjustable thermostat on front cover

“C”indicates evaluation and compliance to either Underwriters

Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2

No. 64/No. 88.

Product Rated Pressure 25 PSI min., 150 PSI max.

Specifications

Certifications ETL Listed to UL 499 and CSA

(all models)

Std. Temp. Settings 120°F (Adjustable 80°F-140°F)

Temp. Accuracy +/–1° at steady state flow

Max Flow Rate

Turn-On

7 GPM @ 60 PSI

0.3 GPM

HA008240/HA011240/HA013240

Size 11.75”H x 7.25”W x 3.75”D

Weight 8 kw: 4.75 lbs. 11 kw/13 kw: 7 lbs.

Unique Features Solid, hand-welded exchanger, 1/2” NPT adapters, 3 foot electric cable and 1/2” compression fittings for water connectors included

7.25” 7.25”

HA018240

Size

Weight

17”H x 14”W x 3.75”D

11.25 lbs.

Unique Features Solid, hand-welded exchanger, 3/4” NPT water connectors for flex hose installation

14”

12”

12”

HA008240 HA011240/HA013240

HA024240/HA027240

Size 17”H x 17”W x 3.75”D

Weight 13.75 lbs.

Unique Features Solid, hand-welded exchanger, 3/4” NPT water connectors for flex hose installation

17”

17”

HA036240

Size 17”H x 19”W x 3.75”D

Weight 17.4 lbs.

Unique Features Solid, hand-welded exchanger, 3/4” NPT water connectors for flex hose installation

19”

17”

17”

18 Information and product specifications contained in this document are subject to change without notice.

ProSeries

For Single Point-of-Use or Multiple Applications in Commercial Applications

Applications

COMING SOON!

• Hand washing

• Standard Hand Sink

0.5-2.2 gpm

0.5 GPM

• Kitchen Sink or Mop Sink 4+ GPM

• Dishwasher 1 to 2 GPM

Average Gallons Per Minute (GPM) based on 2010 Plumbing Standards

Performance Features

• Instant, consistent and endless hot water

• Protected internal temperature control

• 99.8% energy efficient

• Copper immersion heating elements with brass top increases durability and are threaded for easy replacement

• Simple Installation

• Internal temperature control adjust in increments of 1°

• Temperature range 80°-140°F

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Tankless water heater shall be an Eemax ProSeries model number PRO_______________.

PRO008240/PR011240/PR013240

Specifications

Electric Tankless Hot Water Heater

PRO018240

PRO024240/PRO027240

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

PRO036240

Information and product specifications contained in this document are subject to change without notice.

19

ProSeries Commercial

ProSeries

For Single Point-of-Use or Multiple Applications in Commercial Applications

COMING SOON!

TEMPERATURE RISE °F

MODEL NUMBER kW AMPS

RECOMMENDED

WIRE SIZE (CU)

TURN ON

(GPM)

MIN.

FLOW

(GPM)

MAX.

FLOW

(GPM)

1.0

GPM

1.5

GPM

2.0

GPM

2.5

GPM

3.0

GPM

4.0

GPM

240V* 1 MODULES

C PRO008240 8.0 33(1x40)A

C PRO008240 (derated 208V performance) 5.8

28A

C PRO011240 11.0 46(1x50)A

C PRO011240 (derated 208V performance) 8.2

29A

C PRO013240 13.0 54(1x60)A

C PRO013240 (derated 208V performance) 10.1 49(1x60)A

240V* 2 MODULES

C PRO018240 18.0 75(2x38)A

C PRO018240 (derated 208V performance) 13.3 64(2x32)A

240V* 3 MODULES

C PRO024240 24.0 100(3x33)A

C PRO024240 (derated 208V performance) 17.5 84(3x28)A

C PRO027240 27.0 112(3x37)A

8 AWG

*

6 AWG

*

6 AWG

*

8 AWG

*

6 AWG

*

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

4.8

4.8

4.8

4.8

4.8

4.8

7.0

7.0

7.0

7.0

55°

40°

75°

56°

89°

69°

+

90°

+

+

36°

27°

50°

37°

59°

46°

82°

60°

+

+

27°

20°

38°

28°

44°

34°

62°

45°

82°

60°

22°

30°

36°

49°

36°

66°

48°

18°

25°

30°

41°

30°

55°

40°

22°

31°

41°

8 AWG 0.3

0.3

7.0

+ + 92° 74° 62°

30°

46°

* 0.3

0.3

7.0

+ + 68° 55° 45° 34° C PRO027240 (derated 208V performance) 20 96(3x32)A

240V* 4 MODULES

C PRO036240 36.0 150(4x38)A

C PRO036240 (derated 208V performance) 26.6 127(4x32)A

8 AWG

*

0.3

0.3

0.3

0.3

8.0

8.0

+

+

+

+

+

91

98°

73°

82°

61°

62°

45°

Specifications

Electric Tankless Hot Water Heater

5.0

GPM

6.0

GPM

25°

33°

24°

37°

27°

49°

36°

27°

20°

31°

23°

41°

30°

* 240V units can be used on

208V single phase with 25% reduced temperature output.

Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage.

Check with local officials prior to derating the electrical infrastructure.

+ Temperature electronically limited setting on adjustable thermostat on front cover

“C”indicates evaluation and compliance to either Underwriters

Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2

No. 64/No. 88.

Product Rated Pressure 25 PSI min., 150 PSI max.

Specifications

Certifications ETL Listed to UL 499 and CSA

(all models)

Std. Temp. Settings 120°F (Adjustable 80°F-140°F)

Temp. Accuracy +/–1° at steady state flow

Turn-On 0.3 GPM

PRO008240/PRO011240/PRO013240

Size 11.75”H x 7.25”W x 3.75”D

Weight 8 kw: 4.75 lbs. 11 kw/13 kw: 7 lbs.

Unique Features Solid, hand-welded exchanger, 1/2” NPT adapters, 3 foot electric cable and 1/2” compression fittings for water connectors included

3.7

PRO018240

Size

Weight

17”H x 14”W x 3.75”D

11.25 lbs.

Unique Features Solid, hand-welded exchanger, 3/4” NPT water connectors for flex hose installation

3.6 13.9

12.9

11.4

8.8

17.0

15.1

PRO024240/PRO027240

Size 17”H x 17”W x 3.75”D

Weight 13.75 lbs.

Unique Features Solid, hand-welded exchanger, 3/4” NPT water connectors for flex hose installation

3.6

17.0

15.1

5.9

20

5.9

PRO036240

Size

Weight

17”H x 19”W x 3.75”D

17.4 lbs.

Unique Features Solid, hand-welded exchanger, 3/4” NPT water connectors for flex hose installation

3.6

20.8

19.8

17.4 15.1

9.8

Information and product specifications contained in this document are subject to change without notice.

ProAdvantage Series

Digital Temperature Control for Commercial and Industrial Applications

Performance Features

• Cut Energy Waste. Flow switch activates heater only on demand (no standby heat loss) 99% efficient

• Save Water – “Point of Use”

• Continuous Hot Water. No storage capacity to run out

• Easy Installation. Only one cold or hot water line is needed for installation – 3/4” NPT water fittings (except single module units use 1/2” compression fittings)

• Reduces calcification, liming and sedimentation

• External digital temp control

• Reduces installation cost and material. No T&P relief valve needed (check local codes) or venting

• Warranty – Heaters are guaranteed against failure due to leaks of “Heater Body/Element Assembly” for a period of five (5) years and one (1) year on parts – Field serviceable replaceable cartridge element, one (1) year

• LEED credits available

• Aluminum powder coated exterior

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Water heater shall be an Eemax ProAdvantage model number

PA____________________

Tankless Water Heater shall be an Eemax ProAdvantage model, with digital microprocessing temperature control capable of maintaining outlet temperature. Unit shall have 6061-T6 Aircraft Alloy cover. Element shall be replaceable cartridge insert.

Unit shall have replaceable filter in the inlet connector. Element shall Nickel Chrome material. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited.

Unit shall be Eemax or approved equal.

Single Module

Specifications

Electric Tankless Hot Water Heater

Triple Module

Dual Module

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Information and product specifications contained in this document are subject to change without notice.

21

ProAdvantage Series

Digital Temperature Control for Commercial and Industrial Applications

Specifications

Electric Tankless Hot Water Heater

Product Specifications

Single Module Models

PA004120T, PA008208T, PA005240T,

PA007240T, PA010240T, PA012240T,

PA008277T, PA010277T

Dimensions: 9.875” H x 5.3” W x 4” D

Weight: 4.5 lbs.

Cover: Aluminum Powder Coated

Rated 25 PSI min.

Pressure 150 PSI max.

Element: Single replaceable heating cartridge insert

Fittings: 1/2” compression

Temp

Control:

Digital touchpad LED, range 100°F-140°

Dual Module Models

PA014240TC, PA016277TC,

PA019240TC, PA020288TC,

PA023240TC

Dimensions: 10.5” H x 11” W x 4.5” D

Weight: 10.5 lbs.

Cover: Aluminum Powder Coated

Rated 25 PSI min.

Pressure 150 PSI max.

Element: Dual replaceable heating cartridge insert

Fittings: 3/4” NPT

Temp Digital touchpad LED,

Control: range 100°F-140°F

Triple Module Models

PA018208T2T, PA024208T2T,

PA018277T2T, PA024277T2T,

PA032277T2T,

SINGLE PHASE MODEL PA028240T2T

Dimensions: 12.5” H x 15.5” W x

4.5” D

Weight: 15 lbs.

Cover: Aluminum Powder Coated

Rated 45 PSI min.

Pressure 150 PSI max.

Element: Triple replaceable heating cartridge insert

Fittings: 3/4” NPT

Temp Digital touchpad LED,

Control: range 100°F-140°F

MODEL NUMBER kW

SINGLE PHASE 120V – Approximate Weight 4.5 lbs.

C PA004120T 3.5

SINGLE PHASE 208V – Approximate Weight 4.5 lbs.

C PA008208T 8.3

SINGLE PHASE 240V* – Approximate Weight 4.5 lbs.

C PA005240T 4.8

C PA005240T (derated 208V performance)

C PA007240T

3.6

6.5

4.9

C PA007240T (derated 208V performance)

C PA010240T

C PA010240T (derated 208V performance)

C PA012240T

9.5

7

11.5

AMPS

29A

40A

20A

17A

27A

24A

40A

34A

48A

C PA012240T (derated 208V performance) 8.7

SINGLE PHASE 240V* – Approximate Weight 10.5 lbs.

C PA014240TC

C PA014240TC (derated 208V performance)

15 64(2x32)A

11.2

42A

52(2x27)A

19 80(2x40)A C PA019240TC

C PA019240TC (derated 208V performance)

C PA023240TC

C PA023240TC (derated 208V performance)

14

23

17.3

68(2x34)A

96(2x48)A

83(2x42)A

SINGLE PHASE 240V* – Approximate Weight 15 lbs.

C PA028240T2T 28.5 120(3x40)A

RECOMMENDED

WIRE SIZE (CU)

10 AWG

8 AWG

10 AWG

*

10 AWG

*

8 AWG

*

6 AWG

*

8 AWG

*

8 AWG

*

6 AWG

*

6 AWG

MIN. FLOW

(GPM)

0.3

0.7

0.5

0.5

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

MAX. FLOW

(GPM)

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

4.0

0.5

GPM

49°

66°

0.75

GPM

33°

44°

87°

95°

+

+

+

+

+

+

+

+

+

TEMPERATURE RISE °F

1.0

GPM

25°

33°

64°

79°

+

77°

+

95

+

+

+

1.5

GPM

66° 44° 33° 2°

16°

59° 45° 30°

22°

65° 43°

48°

79° 53°

59°

2.0

GPM

48° 32° 24° 16° 16°

68° 51° 41° 34°

2.5

GPM

68° 51° 41° 34°

51°

86° 65° 52° 43°

64

+

79°

+

22°

33°

32°

39°

39°

38°

48

31°

38°

3.0

GPM

26°

32°

79° 63° 53°

59° 47° 39°

+ 77° 64°

C PA028240T2T (derated 208V performance) 20.9 100(3x33)A

SINGLE PHASE 277V – Approximate Weight 4.5 lbs.

C PA008277T

C PA010277T

8

10

SINGLE PHASE 277V – Approximate Weight 10.5 lbs.

29A

36A

C PA016277TC

C PA020277TC

16 58(2x29)A

20 72(2x36)A

THREE PHASE 208V/3 Ø † – Approximate Weight 15 lbs.

C PA018208T2T

C PA024208T2T

18 50A/phase

24 67A/phase

THREE PHASE 480Y/277V †† – Approximate Weight 15 lbs.

*

10 AWG

10 AWG

10 AWG

6 AWG

6 AWG

6 AWG

0.7

0.7

0.7

0.7

0.7

0.7

0.7

4.0

2.5

2.5

3.0

3.0

4.0

4.0

+

+

+

+

+

+

+ + +

73° 55° 37° 27°

69° 46° 34°

+

+

+

+

74° 55° 44° 37°

+

82° 62° 49° 41°

+

57°

48°

69° 55° 46°

82° 66° 55°

C PA018277T2T

C PA024277T2T

18 22A/phase

24 29A/phase

10 AWG

10 AWG

0.7

0.7

4.0

4.0

+

+

+

+

82° 62° 49° 41°

+ 82° 66° 55°

C PA032277T2T 32 39A/phase 6 AWG 0.7

4.0

– + + + + 88° 73°

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

† Delta – No Neutral Leg

†† Wye – Neutral Leg Required

+ Temperature electrically limited to factory preset not-to-exceed temperature.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No.88.

Single Module

5 3/8˝

4 1/4”

7 7/8˝

MOUNTING

LOCATIONS

9 7/8˝

1 3/8˝

OUT IN

1/2˝ COMPRESSION

ELECTRICAL

CONNECTION

Dual Module

11˝

MOUNTING

LOCATIONS

9 1/4˝

8 1/2˝

10 1/2˝

3/4˝ NPT

ELECTRICAL

CONNECTION

OUT

IN

4 1/2˝

10 1/2˝

OUT

Triple Module

15 1/2˝

7”

MOUNTING

LOCATIONS

14˝

IN

3/4˝ NPT

12 1/2˝

3 PHASE ELEC.

CONNECTIONS

(1 3/8˝)

4 1/2˝

SINGLE PHASE ELEC. CONNECTIONS (1 1/8˝ 3 PL)

22

5 3/8˝

4 1/4”

7 7/8˝

MOUNTING

LOCATIONS

9 7/8˝

1 3/8˝

OUT IN

1/2˝ COMPRESSION

ELECTRICAL

CONNECTION

11˝

MOUNTING

LOCATIONS

9 1/4˝

8 1/2˝

10 1/2˝

3/4˝ NPT

ELECTRICAL

CONNECTION

OUT

IN

4 1/2˝

10 1/2˝

15 1/2˝

MOUNTING

LOCATIONS

14˝

3/4˝ NPT

7”

OUT

IN

12 1/2˝

3 PHASE

ELECTRICAL

CONNECTIONS

(3 1/8˝)

SINGLE PHASE

ELECTRICAL

CONNECTIONS

(1 1/8˝ 3 PL)

4 1/2˝

Information and product specifications contained in this document are subject to change without notice.

Series Two, Residential/Commercial “TC”

Staged models (Two heating modules) with thermostatic control

Specifications

Electric Tankless Hot Water Heater

Applications

• Single or Multi fixture

• Residential showers

• Commercial/Industrial

• Photo processing

• Adjustable, precise temperature setting +/–1°F (ambient up to 180°F)

• Solar backup with FS option

Performance Features

• Turns on in stages based on hot water demand

Min. flow 0.7 GPM, max. flow 3 GPM (ML units turn on

0.3 GPM)

• On demand hot water

• Continuous hot water. No storage capacity to run out

• Reduces installation cost and material. No T&P relief valve needed (check local codes) or venting

• Easy installation with integral 3/4” NPT fittings

• Cut energy waste. Flow switch activates heater only on demand (no standby heat loss)

• Reduces calcification

• Two glass-fiber reinforced heater bodies and Ni Chrome elements – a unique, patented flow path ensures optimum heat transfer and extended element life

• Warranty – Five (5) years leaks and one (1) year on parts.

Field serviceable replaceable cartridge element, one (1) year

• Unit mounts on wall

• High temperature limit switch

• LEED credits available

Optional Features

• Factory set ambient to 180°F (FS)

• Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp setting (ML)

• Sanitation 180°F (S)

• N4, N4X (304SS) enclosures

Product Specifications

Dimensions

Weight

Cover

10” x 10.5” x 3”

10.5 lbs.

Enameled steel

Color White

Element Dual replacement cartridge inserts

Thermostatic control (+/-1°F) accuracy

Pipe-Fittings 3/4” NPT fittings at bottom of unit.

Operating Pressure Min. 40 PSI, max. 150 PSI

UL Listing E 36887(M)

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Suggested Specification

Tankless water heater shall be an Eemax Series Two model number EX_________________________.

Heater shall have two heating modules. Element shall be replaceable cartridge insert.

Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with

3/4” NPT water connections. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

NOTE: Refer to rating chart for product information.

Enclosure to be fitted with the following features:

_____ FS

_____ ML

4 lavs 105°F-110°F temp setting

_____ S

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

23

Series Two, Residential/Commercial “TC”

Staged models (Two heating modules) with thermostatic control

Specifications

Electric Tankless Hot Water Heater

Suffix Definitions

FS Factory set ambient to 180°F

ML Multi lavs 0.3 turn on. Staged up to

S

4 lavs 105°F-110°F temp setting

Sanitation 180°F

10.12

10.68

4.32

1.77

.94

UTLET

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

MODEL NUMBER

VOLTS 240*

C EX144TC

C EX144TC (derated 208V performance)

C EX144TC S

C

C

“EX”

15.19

C EX190TC

C EX190TC (derated 208V performance)

C EX190TC S

C EX190TC FS

C EX190TC ML kW

15kW

11.2kW

15kW

15kW

15kW

19kW

14kW

19kW

19kW

19kW

23kW

EX023240TC (derated 208V performance) 17.3kW

EX023240TC S

EX023240TC FS

23kW

23kW

EX023240TC ML

VOLTS 208 Single Phase

C EX1608TC S

C EX1608TC FS

C EX1608TC ML

23kW

16.6kW

16.6kW

16.6kW

AMPS

64(2x32)A

54(2x27)A

64(2x32)A

64(2x32)A

64(2x32)A

80(2x40)A

68(2x34)A

80(2x40)A

80(2x40)A

80(2x40)A

96(2x48)A

83(2x50)A

96(2x48)A

96(2x48)A

96(2x48)A

80(2x40)A

80(2x40)A

80(2x40)A

RECOMMENDED

WIRE SIZE (CU)

MIN. FLOW

(GPM)

8 AWG per module

*

8 AWG per module

8 AWG per module

8 AWG per module

*

8 AWG per module

8 AWG per module

8 AWG per module

6 AWG per module

*

6 AWG per module

6 AWG per module

8 AWG per module

8 AWG per module

8 AWG per module

0.7

0.7

0.3

1.5

GPM

+

+

+

87°

87°

+

+

68°

87°

64°

87°

68°

51°

68°

68°

0.7

0.7

0.3

0.7

0.3

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.7

0.3

75°

75°

75°

TEMPERATURE RISE °F

2.0

GPM

2.5

GPM

79°

59°

79°

79°

79°

48°

65°

65°

65°

51°

38°

51°

51°

57°

57°

57°

41°

52°

38°

52°

41°

31°

41°

41°

62°

47°

62°

62°

62°

45°

45°

45°

3.0

GPM

52°

52°

52°

43°

43°

52°

39°

34°

43°

32°

43°

34°

26°

34°

34°

38°

38°

38° NEMA 4/4X

EX160TC

EX160TC S

OUTLET

INLET

16kW

16kW

58(2x29)A 10 AWG per module

58(2x29)A 10 AWG per module

0.7

0.7

73°

73°

55°

55°

44°

44°

36°

36°

4XØ .500

MOUNTING HOLES

16kW

16kW

58(2x29)A 10 AWG per module

58(2x29)A 10 AWG per module

8 AWG per module

2.89

1.93

6 AWG

2.21

6 AWG

0.7

0.7

0.7

73° 55° 44° 36°

18.50

20.00

8.78

EX160TC ML

EX200TC

EX200TC S

EX200TC FS

EX200TC ML

CNL Models

C EX144TC CNL

C EX144TC S CNL

C EX144TC FS CNL

C EX144TC ML CNL

C EX190TC CNL

C EX190TC S CNL

C EX190TC FS CNL

C EX190TC ML CNL

C EX1608TC CNL

C EX1608TC S CNL

7.02

20kW

20kW

20kW

20kW

15kW

15kW

15kW

15kW

19kW

19kW

19kW

19kW

16.6kW

72(2x36)A

72(2x36)A

72(2x36)A

72(2x36)A

64A

64A

64A

64A

80A

80A

80A

80A

80A

8 AWG per module

8 AWG per module

6 AWG

6 AWG

4 AWG

4 AWG

4 AWG

4 AWG

4 AWG

0.3

0.7

0.3

0.7

0.7

0.7

0.3

0.7

0.7

0.7

0.3

0.7

73°

+

+

+

+

68°

68°

68°

87°

87°

87°

87°

75°

55°

68°

INLET

68°

68°

68°

51°

51°

51°

51°

65°

65°

65°

65°

57°

44°

54°

54°

54°

54°

41°

41°

41°

41°

52°

52°

52°

52°

45°

36°

46°

46°

46°

46°

34°

34°

34°

34°

43°

43°

43°

43°

38°

OUTLET INLET 16.6kW

80A 4 AWG 0.7

75° 57° 45° 38°

C EX1608TC FS CNL 16.6kW

80A 4 AWG 0.7

75° 57° 45° 38°

2.80

C EX1608TC ML CNL 16.6kW

80A 0.3

75° 57° 45° 38°

1.97

4.07 4.00 * 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

+ Temperature electrically limited to factory preset not-to-exceed temperature.

NEMA 4/4X ENCLOSURE

Pg 24

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

SERIES 2

EX190TC

Pg 20

77% REDUCTION

NEMA 4/4X ENCLOSURE

EX208C Pg 20/22

SERIES 3

1 PHASE EX208C

Pg 29

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

SERIES 2

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

12.12

4.32

1.87

.90

1.30

OUTLET

9.96

20.19

INLET

SERIES 4

ELECTRICAL

CONNECTION (4)

24 Information and product specifications contained in this document are subject to change without notice.

12.14

18.19

NEMA

4/4X

16.00

14.50

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL CONNECTION

8.78

OUTLET

2.21 7.02

INLET

20.00

18.50

4XØ .500

MOUNTING HOLES

77% REDUCTION

NEMA 4/4X

“EX”

Series Two, Commercial “T2”

Parallel models (Two heating modules) with thermostatic control

Specifications

Electric Tankless Hot Water Heater

Applications

• Single high volume fixture

• Commercial dishwashers

• Booster (Solar backup)

• Commercial/Industrial

• Adjustable, precise temperature setting +/–1°F (ambient up to 180°F)

Performance Features

• Parallel turn on. Min. flow 1.5 GPM, max. flow 4 GPM

• On demand hot water

• Continuous hot water. No storage capacity to run out

• Reduces installation cost and material. No T&P relief valve needed (check local codes) or venting

• Easy installation with integral 3/4” NPT fittings

• Cut energy waste. Flow switch activates heater only on demand (no standby heat loss)

• Meets ANSI Z358.1 tepid water requirement (EE option)

• Reduces calcification

LAV SHOWER KITCHEN

• Two glass reinforced heater bodies and Ni Chrome elements – a unique, patented flow path ensures optimum heat transfer and extended element life

• Warranty – Five (5) years leaks, and one (1) year on parts –

Field serviceable replaceable cartridge element, one (1) year

• Unit mounts on wall Multi Outlet

• High temperature limit switch

• LEED credits available

Eemax

HOT

OUTLET

COLD

INLET

Optional Features

• Emergency eye/face wash ANSI Z358.1 (EE)

• Factory set ambient to 180°F (FS)

• Sanitation 180°F (S)

• N4, N4X (304SS) enclosures

Product Specifications

Dimensions

Weight

Cover

10” x 10.5” x 3”

10.5 lbs.

Enameled steel

Color White

Element Dual replacement cartridge inserts.

Thermostatic control (+/-1°F) accuracy

Pipe-Fittings 3/4” NPT fittings at bottom of unit.

Operating Pressure Min. 40 PSI, max. 150 PSI

UL Listing E 36887(M)

U.S. Patent #’s: 4,762,980 and 4,960,976

Suggested Specification

Tankless water heater shall be an Eemax Series Two model number EX_________________________.

Heater shall have two heating modules. Element shall be replaceable cartridge insert.

Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with

3/4” NPT water connections. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

NOTE: Refer to rating chart for product information.

Enclosure to be fitted with the following features:

_____ EE Emergency Eyewash. Meets ANSI tepid water requirements

_____ FS Factory Set. Customer specified factory-set not to exceed temperature ambient to 180°F

_____ S Sanitation. Factory preset not to exceed temperature of 180°F

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

COMMERCIAL

DISHWASHER

BOOSTER

HOT

OUTLET

140°F

TANK

WATER

HEATER

UTILITY SINK

Eemax COLD

INLET

Eemax

180°F

HOT OUTLET

UTILITY SINK

Booster

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

COLD INLET

Information and product specifications contained in this document are subject to change without notice.

25

Series Two, Commercial “T2”

Parallel models (Two heating modules) with thermostatic control

Specifications

Electric Tankless Hot Water Heater

Suffix Definitions

EE Meets ANSI Z358.1 emergency eye/face wash tepid water requirements

FS Factory set ambient to 180°F

S Sanitation 180°F

10.12

4.32

1.77

.94

UTLET

10.68

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

NEMA 4/4X

MODEL NUMBER

VOLTS 240*

C EX144T2

EX144T2 (derated 208V performance)

C EX144T2 EE

C

C

“EX”

15.19

C EX190T2

EX190T2 (derated 208V performance)

C EX190T2 EE

C EX190T2 FS

C EX190T2 S

EX022340T2 (derated 208V performance)

EX022340T2 EE

EX022340T2 FS

EX022340T2 S

VOLTS 208 Single Phase

C EX1608T2

C EX1608T2 EE

C EX1608T2 FS

C EX1608T2 S

VOLTS 277

EX160T2

OUTLET

INLET kW

19kW

19kW

23kW

17.3KW

23kW

23kW

23kW

15kW

11.2KW

15kW

15kW

15kW

19kW

14KW

19kW

16.6kW

16.6kW

16.6kW

16.6kW

16kW

AMPS

64(2x32)A

54(2x27)A

64(2x32)A

64(2x32)A

64(2x32)A

80(2x40)A

68(2x34)A

80(2x40)A

80(2x40)A

80(2x40)A

96(2x48)A

83(2x42)A

96(2x48)A 16.00

96(2x48)A

96(2x48)A

80(2x40)A

80(2x40)A

80(2x40)A

80(2x40)A

58(2x29)A

RECOMMENDED

WIRE SIZE (CU)

8 AWG per module

*

8 AWG per module

8 AWG per module

8 AWG per module

*

8 AWG per module

8 AWG per module

8 AWG per module

6 AWG per module

*

6 AWG per module

6 AWG per module

8 AWG per module

8 AWG per module

8 AWG per module

8 AWG per module

10 AWG per module

1.5

GPM

+

+

+

+

+

+

79°

68°

+

64

+

68°

51°

68°

68°

75°

75°

75°

75°

73°

TEMPERATURE RISE °F

2.0

GPM

2.5

GPM

3.0

GPM

51°

38°

51°

51°

79°

59°

79°

79°

79°

48

65°

65°

65°

57°

57°

57°

57°

55°

62°

62°

62°

52°

52°

62°

47°

41°

52°

38

52°

41°

31°

41°

41°

45°

45°

45°

45°

44°

34°

43°

32

43°

34°

26°

34°

34°

38°

38°

38°

38°

52°

39°

52°

52°

52°

36°

4.0

GPM

39°

39°

39°

32°

32°

39°

29°

25°

32°

24

32°

25°

19°

25°

25°

28°

28°

28°

28°

27°

4XØ .500

MOUNTING HOLES

16kW

CONNECTION (3)

16kW

58(2x29)A

72(2x36)A

72(2x36)A

8.78

10 AWG per module

8 AWG per module

8 AWG per module

2.21

6 AWG

73°

7.02

68°

55°

68°

68°

44° 36° 27°

18.50

20.00

8.78

EX160T2 FS

EX160T2 S

EX200T2

EX200T2 EE

EX200T2 FS

EX200T2 S

CNL Models

C EX144T2 CNL

C EX144T2 EE CNL

C EX144T2 FS CNL

C EX144T2 S CNL

C EX190T2 CNL

C EX190T2 EE CNL

C EX190T2 FS CNL

C EX190T2 S CNL

C EX1608T2 CNL

7.02

20kW

20kW

20kW

20kW

15kW

15kW

15kW

15kW

19kW

19kW

19kW

19kW

58(2x29)A

58(2x29)A

72(2x36)A

72(2x36)A

64 A

64 A

64 A

64 A

80 A

80 A

80 A

80 A

10 AWG per module

10 AWG per module

2.89

8 AWG per module

1.93

6 AWG

6 AWG

6 AWG

4 AWG

4 AWG

4 AWG

4 AWG

73°

73°

+

+

+

+

68°

68°

68°

+

+

+

+

55°

55°

68°

68°

51°

51°

51°

51°

65°

65°

65°

65°

44°

44°

54°

54°

54°

54°

41°

41°

41°

41°

52°

52°

52°

52°

36°

36°

46°

46°

46°

46°

34°

34°

34°

34°

43°

43°

43°

43°

27°

27°

34°

34°

34°

34°

25°

25°

25°

25°

32°

32°

32°

32°

OUTLET INLET 16.6kW

80 A 4 AWG 75° 57° 45° 38° 28°

C EX1608T2 EE CNL 16.6kW

80 A 4 AWG 75° 57° 45° 38° 28°

2.80

C EX1608T2 FS CNL 16.6kW

80 A 75° 57° 45° 38° 28°

1.97

4.07 4.00

C EX1608T2 S CNL 16.6kW

80 A 4 AWG

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

75° 57° 45° 38° 28°

NEMA 4/4X ENCLOSURE

+ Temperature electrically limited to factory preset not-to-exceed temperature.

Pg 24

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

SERIES 2

EX190TC

Pg 20

77% REDUCTION

NEMA 4/4X ENCLOSURE

EX208C Pg 20/22

SERIES 3

1 PHASE EX208C

Pg 29

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

SERIES 2

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

12.12

4.32

1.87

.90

1.30

OUTLET

9.96

20.19

INLET

SERIES 4

ELECTRICAL

CONNECTION (4)

26 Information and product specifications contained in this document are subject to change without notice.

12.14

18.19

NEMA

4/4X

16.00

14.50

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL CONNECTION

8.78

OUTLET

2.21 7.02

INLET

20.00

18.50

4XØ .500

MOUNTING HOLES

77% REDUCTION

NEMA 4/4X

“EX”

Series Three, Residential/Commercial

Staged or parallel models (Three heating modules) thermostatic control

Specifications

Electric Tankless Hot Water Heater

Applications

• Whole house, multi fixture 4 GPM unit has capacity to handle up to two showers at a time

• Jetted bathtub booster (T3 option)

Performance Features

• On demand hot water. Cuts energy waste. No stand-by heat loss. 99% efficiency rating

• Thermostatic control. Microprocessor provides precise outlet temperatures

• Regulates power to required flow

• Continuous hot water. No storage capacity to run out

• Reduces installation cost and material. Requires only one cold water input line, no solder connections. No T&P relief valve needed (check local codes) or venting

• Easy installation with integral 3/4” NPT fittings

• Reduces calcification and sedimentation

• Three glass-fiber reinforced heater bodies and Ni Chrome elements – a unique, patented flow path ensures optimum heat transfer and extended element life

• Warranty – Five (5) years leaks and one (1) year on parts.

Field serviceable replaceable cartridge element, one (1) year

• Unit mounts on wall

• High temperature limit switch

• LEED credits available

Optional Features

• T2T – Staged heating elements. Turn on min. flow 0.7 GPM, max. flow 4 GPM (ML units – 0.3 GPM turn on)

• T3 – Parallel heating elements. Turn on min. flow 1.8 GPM,

max. flow 5 GPM. Recommended for commercial uses only

• Factory set ambient to 180° (FS)

• Multi lavs. Staged up to 4 lavs 105°F-110°F temp setting,

0.3 GPM turn on, aerators supplied (ML)

• Sanitation 180F° (S)

• N4, N4X (304SS) enclosures

Product Specifications

Dimensions

Weight

15 1/4” x 12 1/4” x 4 1/4”

15 lbs

Operating Pressure Min. 45 PSI, max. 150 PSI

Cover

Color

Element

Pipe Fitting

UL listed

Enameled Steel

White

Triple replaceable cartridge inserts.

Thermostatic control (+/-1°F) accuracy

3/4” NPT at bottom of unit. (5/8 ” OD) or 3/4” NPT Adapter

E86887(M)

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Suggested Specification

Tankless water heater shall be an Eemax Series Three model number EX280_________________.

Heater shall have three heating modules. Element shall be replaceable cartridge insert. Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with 3/4” NPT water connections. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

NOTE: Refer to rating chart for product information.

Enclosure to be fitted with the following features:

_____ T2T

_____ T3

_____ FS

_____ ML

4 lavs 105°F-110°F temp setting

_____ S

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

27

10.12

Series Three Residential/Commercial

For Commercial and Industrial Applications

Specifications

Electric Tankless Hot Water Heater

Suffix Definitions

T3 Parallel heating elements

EE Meets ANSI Z358.1 emergency eye/face wash tepid water requirements

FS Factory set ambient to 180°F

ML Multi lavs 0.3 turn on. Staged up to 6

S lavs 105°F-110°F temp setting

Sanitation 180°F

MODEL NUMBER kW AMPS

RECOMMENDED

WIRE SIZE (CU)

2.5

GPM

TEMPERATURE RISE °F

3.0

GPM

4.0

GPM

5.0 GPM

T3 ONLY

VOLTS 240*

C EX280T2T

C EX280T2T (derated 208V performance)

C EX280T2T ML

C EX280T2T FS

C EX280T2T S

C EX280T3

C EX280T3 (derated 208V performance)

28.5

20.9

28.5

28.5

28.5

28.5

20.9

120(3X40)A

100(3X33)A

120(3X40)A

120(3X40)A

120(3X40)A

120(3X40)A

100(3x33)A

8 AWG per module

*

8 AWG per module

8 AWG per module

8 AWG per module

8 AWG per module

*

76°

57°

76°

76°

76°

76°

57°

65°

48°

65°

65°

65°

65°

48°

49°

36°

49°

49°

49°

49°

36°

38°

49°

C EX280T3 S

C EX280T3 FS

CNL Models

C EX280T2T CNL

28.5

28.5

28.5

120(3X40)A

120(3X40)A

120 A

8 AWG per module

8 AWG per module

1 AWG

76°

76°

76°

65°

65°

65°

49°

49°

49°

38°

38°

C EX280T2T ML CNL

C EX280T2T FS CNL

28.5

28.5

120 A

120 A

1 AWG

1 AWG

76°

76°

65°

65°

49°

49°

C EX280T2T S CNL

C EX280T3 CNL

28.5

28.5

120 A

120 A

1 AWG

1 AWG

76°

76°

65°

65°

49°

49°

38°

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88. CNL SKUs are Canada specific.

10.68

“EX” NEMA 4/4X

15.19

20.00

18.50

4XØ .500

MOUNTING HOLES

12.14

16.00 14.50

4.32

1.77

.94

UTLET

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

NEMA 4/4X

16.00

14.50

4XØ .500

MOUNTING HOLES

18.50

20.00

4.32

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL

CONNECTION (3)

8.78 OUTLET

2.89

1.93

2.21 7.02

INLET

12.12

20.19

4.32

1.87

.90

1.30

OUTLET

9.96

INLET

SERIES 4

ELECTRICAL

CONNECTION (4)

12.14

18.19

NEMA

4/4X

16.00

14.50

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL CONNECTION

8.78

OUTLET

2.21 7.02

INLET

4XØ .500

MOUNTING HOLES

8.78

INLET OUTLET

2.80

1.97

4.07 4.00

SERIES 3

NEMA 4/4X ENCLOSURE

Pg 24

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

28

SERIES 2

EX190TC

Pg 20

77% REDUCTION

NEMA 4/4X ENCLOSURE

EX208C Pg 20/22

SERIES 2

SERIES 3

1 PHASE EX208C

Pg 29

Information and product specifications contained in this document are subject to change without notice.

-0

-1

-10

-11

-12

-13

-6

-7

-8

-9

-2

-3

-4

-5

-14

-15

-16

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

77% REDUCTION

NEMA 4/4X

“EX”

Series Four, Residential/Commercial

Staged or parallel models (Four heating modules) thermostatic control

Specifications

Electric Tankless Hot Water Heater

Applications

• Whole house unit has capacity to handle up to three showers at a time

• Multi fixture, 6 GPM max.

Performance Features

• On demand hot water. Cuts energy waste. No stand-by heat loss. 99% efficiency rating

• Thermostatic control. Microprocessor provides precise outlet temperatures

• Regulates power to required flow

• Continuous hot water. No storage capacity to run out

• Reduces installation cost and material. Requires only one cold water input line, no solder connections. No T&P relief valve needed (check local codes) or venting

• Easy installation with integral 3/4” NPT fittings

• Reduces calcification and sedimentation

• Four glass-fiber reinforced heater bodies and Ni Chrome elements – a unique, patented flow path ensures optimum heat transfer and extended element life

• Warranty – Five (5) years leaks and one (1) year on parts

Field serviceable replaceable cartridge element, one (1) year

• Unit mounts on wall

• High temperature limit switch

• LEED credits available

Optional Features

• T2T2 – Staged heating elements. Turn on min. flow 0.9 GPM, max. flow 6 GPM

• T4 – Parallel heating elements. Turn on min. flow 1.8 GPM, max. flow 8 GPM. Recommended for commercial uses only

• Factory set ambient to 180°F (FS)

• Sanitation 180°F (S)

• N4, N4X (304SS) enclosures

Specifications

Dimensions

Weight

20 3/16” x 12 1/8” x 4 1/8”

23 lbs.

Operating Pressure 45 PSI, max. 150 PSI

Cover

Color

Element

Enameled Steel

White

Four replaceable cartridge inserts

Thermostatic control (+/-1F°) accuracy

Pipe Fitting

UL listed

3/4” NPT

E86887(M)

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Suggested Specification

Tankless water heater shall be an Eemax “Series Four” model number EX380_________________.

Heater shall have four heating modules. Element shall be replaceable cartridge insert.

Unit shall have a replaceable filter in the inlet connector. Heater shall be fitted with

3/4” NPT water connections. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal.

NOTE: Refer to rating chart for product information.

Enclosure to be fitted with the following features:

_____ T2T2

_____ T4

_____ FS

_____ S

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

29

10.68

“EX”

15.19

10.12

12.14

4.32

1.77

.94

UTLET

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

NEMA 4/4X

4XØ .500

MOUNTING HOLES

4.32

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL

CONNECTION (3)

18.50

20.00

NEMA 4/4X

16.00 14.50

8.78 OUTLET

2.89

1.93

2.21 7.02

INLET

Series Four, Residential/Commercial

Staged or parallel models (Four heating modules) thermostatic control

Suffix Definitions

T4 Parallel heating Elements

FS Factory set ambient to 180°F

S Sanitation 180°F

Specifications

Electric Tankless Hot Water Heater

MODEL NUMBER kW AMPS

RECOMMENDED

WIRE SIZE (CU)

2.5

GPM

3.0

GPM

TEMPERATURE RISE °F

4.0

GPM

5.0

GPM

6.0

GPM

8.0

GPM

VOLTS 240*

C EX380T2T2

EX380T2T2 (derated 208V performance)

C EX380T2T2 FS

38kW

27.9

38kW

160(4x40)A

134(4x33)A

160(4x40)A

8 AWG per module

*

8 AWG per module

+

76°

+

86°

64°

86°

65°

48°

65°

52°

38°

52°

43°

32°

43°

24°

C EX380T2T2 S

C EX380T4

38kW

38kW

160(4x40)A

160(4x40)A

8 AWG per module

8 AWG per module

+

+

86°

86°

65°

65°

52°

52°

43°

43°

32°

C EX380T4 (derated 208V performance) 27.9

134(4x33)A * 76° 64° 48° 38° 32° 24°

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

+Temperature electrically limited to factory preset not-to-exceed temperature.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.

20.00

18.50

20.19

18.19

4XØ .500

MOUNTING HOLES

12.14

12.12

4.32

1.87

.90

1.30

OUTLET

9.96

INLET

SERIES 4

ELECTRICAL

CONNECTION (4)

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL CONNECTION

NEMA

4/4X

16.00

14.50

8.78

OUTLET

2.21 7.02

INLET

20.00

18.50

4XØ .500

MOUNTING HOLES

8.78

2.80

1.97

4.07

OUTLET

4.00

INLET

SERIES 2

EX190TC

Pg 20

77% REDUCTION

NEMA 4/4X ENCLOSURE

EX208C Pg 20/22

SERIES 3

1 PHASE EX208C

Pg 29

SERIES 2

SERIES 3

NEMA 4/4X ENCLOSURE

Pg 24

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

-4

-5

-6

-7

-0

-1

-2

-3

-8

-9

-10

-11

-12

-13

30

-16

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

Information and product specifications contained in this document are subject to change without notice.

77% REDUCTION

NEMA 4/4X

“EX”

Three Phase Series

Triple module, commercial/industrial thermostatic 3-phase heater

Specifications

Electric Tankless Hot Water Heater

Applications

• Eye/face wash

• Where tepid water is needed

• Multiple lavatories

• Restaurants and other food service requirements

• Booster applications

• Manufacturing and wash down processes

• Commercial and industrial

Performance Features

• Hot or cold water feed

• Available electrical models are 480V Delta (ED models) or

208V Delta (EX models) no neutral leg required

• Fitted with 1/2” compression fittings and electrical entry on the bottom

• Built in over temp protection

• Flow switch activates heater only on demand (no standby heat loss) – 99% efficient

• Save water – “Point of use application”

• Continuous hot water – no storage capacity to run out

• Factory set temperature available. Range ambient to 180°F

• Capacity to 5 GPM (T3 only), 4 GPM (T2T)

• Thermostatic control. Microprocessor provides precise outlet temperatures

• Reduces calcification, liming and sedimentation

• Warranty – Five (5) years leaks and one (1) year on parts –

Field serviceable replaceable cartridge element, one (1) year

Optional Features

• Emergency eye/face wash ANSI Z358.1 (EE)

• Factory set ambient to 180°F (FS)

• Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp setting, aerators supplied (ML)

• Sanitation 180°F (S)

• N4, N4X (304SS) enclosures

Product Specifications:

Dimensions

Weight

15 1/4” x 12 1/4” x 4 1/4”

Cover

Color

Element

Fittings

Pressure

15 lbs.

Powder Coated Steel

White

Triple replaceable Ni Chrome cartridge elements insert

1/2” compression fittings at BOTTOM of unit

Min. 25 PSI, max. 150 PSI

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

(Representational Image)

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Electrical configuration and requirements

All Eemax three phase units are custom made to order and as such, are nonreturnable and non-refundable. We urge you, therefore, to check your electrical supply, making sure all criteria for operating your Eemax water heater are met.

Eemax 600v, 480v and 208v

Three Phase Units

Delta Configuration

Requires: 3 Lives and 1 Ground (earth)

L1

L2

L3

Suggested Specification

Tankless water heater shall be an Eemax “Three Phase” model number _________________________.

Element shall be replaceable cartridge insert. Element shall be iron free, Nickel Chrome material. Heater shall be fitted with 1/2” compression fittings. Heater shall be installed upright with water connections on bottom. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal. NOTE: Refer to rating chart for product information.

Enclosure to be fitted with the following features:

_____ EE Emergency Eyewash. Meets ANSI tepid water requirements

_____ FS Factory Set. Customer specified factory-set not

_____ to exceed temperature ambient to 180°F

Multi lavs 0.3 GPM turn on, staged up to

_____ S

4 lavs 105°F-110°F temp setting, aerators supplied

Sanitation. Factory preset not to exceed temperature of 180°F

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

31

10.68

“EX”

15.19

10.12

12.14

4.32

1.77

.94

UTLET

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

NEMA 4/4X

16.00

14.50

4XØ .500

MOUNTING HOLES

18.50

20.00

4.32

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL

CONNECTION (3)

NEMA 4/4X

16.00 14.50

20.00

18.50

8.78 OUTLET

2.89

1.93

2.21 7.02

INLET

4XØ .500

MOUNTING HOLES

12.12

20.19

Three Phase Series

Triple module, commercial/industrial thermostatic 3-phase heater

Suffix Definitions

EE Meets ANSI Z358.1 emergency eye/face wash tepid water requirements

FS Factory set ambient to 180°F

ML Multi lavs 0.3 turn on. Staged up to 4

S lavs 105°F-110°F temp setting

Sanitation 180°F

MODEL NUMBER

VOLTS 208v/3 Ø

EX180T2T

EX240T3 FS

VOLTS 480v Delta

ED020480T2T

ED020480T2T S

ED020480T2T ML

ED020480T2T FS

ED020480T3

ED020480T3 EE

ED020480T3 S

ED024480T2T

ED024480T2T S

ED024480T2T ML

ED024480T2T FS

ED024480T3

ED024480T3 EE

ED024480T3 S

EX180T2T EE

EX180T2T S

EX180T2T ML

EX180T2T FS

EX180T3

EX180T3 EE

EX180T3 S

EX180T3 FS

EX240T2T

EX240T2T EE

EX240T2T S

EX240T2T ML

EX240T2T FS

EX240T3

EX240T3 EE

EX240T3 S

ED032480T2T

ED032480T2T S

ED032480T2T ML

ED032480T2T FS

ED032480T3

ED032480T3 EE

ED032480T3 S

ED032480T3 FS kW

24kW

24kW

24kW

24kW

24kW

24kW

32kW

32kW

20kW

20kW

20kW

20kW

20kW

20kW

20kW

24kW

32kW

32kW

32kW

32kW

32kW

32kW

18kW

24kW

24kW

24kW

24kW

24kW

24kW

24kW

24kW

24kW

18kW

18kW

18kW

18kW

18kW

18kW

18kW

18kW

AMPS

PER PHASE

24A/phase

24A/phase

24A/phase

24A/phase

24A/phase

24A/phase

24A/phase

29A/phase

29A/phase

29A/phase

29A/phase

29A/phase

29A/phase

29A/phase

38A/phase

38A/phase

38A/phase

38A/phase

38A/phase

38A/phase

38A/phase

38A/phase

50A/phase

50A/phase

50A/phase

50A/phase

50A/phase

50A/phase

50A/phase

50A/phase

50A/phase

67A/phase

67A/phase

67A/phase

67A/phase

67A/phase

67A/phase

67A/phase

67A/phase

67A/phase

12.14

18.19

Specifications

Electric Tankless Hot Water Heater

NEMA

4/4X

TURN-ON

(GPM)

1.8

1.8

0.7

0.7

0.7

0.3

0.7

1.8

1.8

1.8

1.8

0.7

0.7

0.7

0.3

0.7

0.3

0.7

1.8

1.8

1.8

1.8

0.3

0.7

1.8

1.8

1.8

0.7

0.7

0.7

1.8

1.8

0.7

1.8

1.8

1.8

0.7

0.7

0.7

0.3

RECOMMENDED

WIRE SIZE (CU)

2.0

GPM

TEMPERATURE RISE °F

2.5

GPM

3.0

GPM

4.0

GPM

5.0

GPM

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

6AWG

6AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

10 AWG

6AWG

6AWG

10 AWG

10 AWG

10 AWG

10 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

6 AWG

55°

55°

73°

73°

55°

55°

55°

55°

46°

46°

46°

55°

46°

46°

46°

46°

73°

73°

73°

73°

73°

73°

55°

55°

55°

55°

41°

55°

55°

55°

55°

55°

41°

41°

41°

41°

41°

41°

41°

41°

41°

41°

55°

55°

41°

41°

41°

41°

34°

34°

34°

41°

34°

34°

34°

34°

55°

55°

55°

55°

55°

55°

43°

43°

43°

43°

32°

43°

43°

43°

43°

43°

32°

32°

32°

32°

32°

32°

32°

32°

33°

33°

33°

27°

27°

27°

43°

43°

43°

43°

34°

34°

25°

34°

34°

25°

25°

25°

66°

66°

87°

87°

66°

66°

66°

66°

55°

55°

55°

66°

55°

55°

55°

55°

87°

87°

87°

87°

87°

87°

66°

66°

66°

66°

49°

66°

66°

66°

66°

66°

49°

49°

49°

49°

49°

49°

49°

49°

82°

82°

109°

109°

82°

82°

82°

82°

68°

68°

68°

82°

68°

68°

68°

68°

109°

109°

109°

109°

109°

109°

82°

82°

82°

82°

61°

82°

82°

82°

82°

82°

61°

61°

61°

61°

61°

61°

61°

61°

20.00

18.50

4XØ .500

MOUNTING HOLES

16.00

14.50

4.32

1.87

.90

1.30

OUTLET

9.96

INLET

32

SERIES 4

ELECTRICAL

CONNECTION (4)

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL CONNECTION

8.78

OUTLET INLET

2.21 7.02

Information and product specifications contained in this document are subject to change without notice.

8.78

2.80

1.97

4.07

OUTLET

4.00

INLET

SERIES 2

EX190TC

Pg 20

77% REDUCTION

NEMA 4/4X ENCLOSURE

EX208C Pg 20/22

SERIES 3

1 PHASE EX208C

Pg 29

SERIES 2

SERIES 3

NEMA 4/4X ENCLOSURE

Pg 24

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

-12

-13

-14

-15

-16

-8

-9

-10

-11

-4

-5

-6

-7

-0

-1

-2

-3

77% REDUCTION

NEMA 4/4X

“EX”

De-Ionized, Single Module

Stainless steel and engineered plastics for all wetted components

Applications

• Microchip manufacturing

• Pharmaceutical production

• High tolerance component cleaning

• Ultrasonic cleaning

• Spray rinse tank

• Batch chemical mixing

Performance Features

• Hot or cold water feed.

• Capable of heating high purity water with state of the art materials used in construction, rated for purity levels up to

18 MEG OHM

• Proven by independent analytical laboratory to maintain water purity. Test results available upon request

• Compact size allows for easy installation close to the point-of-use

• Thermostatic temperature control available with highly accurate micro processor to deliver +/–1°F outlet accuracy

• Eliminate deadlegs. Unique flow activated design allows for constant water movement, even when not heating

• Easy installation

Product Specifications

Dimensions

Weight:

Fittings

Temp Accuracy

10 3/4”H x 5 1/4”W x 2 7/8”D

Approximately 4 lbs.

1/2” compression

+/–1° outlet accuracy

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Tankless water heater shall be an Eemax De-Ionized model number EX___________.

Enclosure to be fitted with the following features:

Heating element shall be replaceable element cartridge. Unit shall be capable of heating water up to 18 MEG OHM quality or approved equal.

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Specifications

Electric Tankless Hot Water Heater

Eemax

Ultrasonic

Cleaning Tank

TOOL

1/8”

TEFLON

TUBING

DI RETURN

5/8” OD TEFLON TUBING

15˝

208V

480/277V

3-PHASE/5 WIRE

HEATER

(3.6”

DEEP)

12˝

SHUTOFF

VALVE

CHECK VALVE

1/2” FPT

X TUBE

5/8” OD TEFLON

TUBING

DI SUPPLY

3-PHASE UNIT

ON LOOP WITH RETURN

Information and product specifications contained in this document are subject to change without notice.

33

De-Ionized, Single Module

Stainless steel and engineered plastics for all wetted components

“EX”

5.22

3.00

9.67

1.11

OUTLET

1.50

INLET

“SP”

OUTLET

1.50

INLET

1.11

.81

9.67

.81

Specifications

Electric Tankless Hot Water Heater

NEMA 4/4X

For EX version only. NEMA cabinets not available for SP version.

VOLTS 120

C EX2412T DI

9.84

7.30 kW

2.4kW

C EX3012T DI 3.0kW

C EX3512T DI

VOLTS 240*

C EX35T DI

C EX48T DI

C EX55T DI

C EX65T DI

4X Ø.25

MOUNTING

HOLES

C EX75T DI

C EX95T DI

VOLTS 208 Single Phase

C EX8208T DI

VOLTS 277

EX3277T DI

EX4277T DI

3.5kW

3.5kW

4.8kW

5.5kW

6.5kW

7.5kW

9.5kW

8.3kW

3.0kW

4.1kW

AMPS

20A

25A

29A

15A

20A

23A

27A

32A

40A

40A

RECOMMENDED

WIRE SIZE (CU)

10 AWG

10 AWG

10 AWG

14 AWG

12 AWG

10 AWG

10 AWG

8 AWG

8 AWG

8 AWG

0.5

GPM

48°

64°

75°

33°

41°

48°

11A

15A

14 AWG

14 AWG

41°

56°

6.0kW

22A 10 AWG –

EX80T DI

EX90T DI

OUTLET INLET 8.0kW

9.0kW

29A

33A

10 AWG

8 AWG

1.07

EX100T DI

1.50

10.0kW

36A 8 AWG –

4.17 be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

“C” indicates evaluation and compliance to Underwriters Laboratories (UL) under CAN/CSA-C22.2 No. 64/No. 88.

0.75

GPM

TEMPERATURE RISE °F

1.0

GPM

1.5

GPM

32°

42°

50°

59°

68°

87°

22°

27°

32°

76°

27°

37°

55°

73°

82°

91°

20°

28°

41°

55°

61°

68°

24°

31°

38°

44°

51°

65°

16°

20°

24°

57°

16°

21°

25°

30°

34°

43°

11°

14°

16°

38°

14°

18°

27°

36°

41°

46°

2.0

GPM

12°

16°

19°

22°

26°

32°

10°

12°

28°

10°

14°

20°

27°

31°

34°

5.22

3.00

34

OUTLET

1 1/2”

INLET

3/4”

5 1/4” 2 7/8”

5 1/4”

10 3/4”

10 3/4”

9 3/4”

Information and product specifications contained in this document are subject to change without notice.

2 7/8”

OUTLET

1 1/2”

INLET

9 3/4”

3/4”

De-Ionized, Dual Module

Stainless steel and engineered plastics for all wetted components

Applications

• Microchip manufacturing

• Pharmaceutical production

• High tolerance component cleaning

• Ultrasonic cleaning

• Spray rinse tank

• Batch chemical mixing

Quality Features

• Hot or cold water feed

• Capable of heating high purity water with state of the art materials used in construction, rated for purity levels up to

18 MEG OHM

• Proven by independent analytical laboratory to maintain water purity. Test results available upon request

• Compact size allows for easy installation close to the point-of-use

• Thermostatic temperature control available with highly accurate micro processor to deliver +/–1°F outlet accuracy

• Eliminate deadlegs. Unique flow activated design allows for constant water movement, even when not heating

• Easy installation

Product Specifications

Dimensions

Weight:

10 3/4”H x 5 1/4”W x 2 7/8”D

Fittings

Temp Accuracy

Approximately 10 lbs.

1/2” compression

+/–1° outlet accuracy

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

Suggested Specification

Tankless water heater shall be an Eemax De-Ionized model number EX___________.

Heating element shall be replaceable element cartridge. Unit shall be capable of heating water up to 18 MEG OHM quality or approved equal.

Enclosure to be fitted with the following features:

_____ TC

_____ T2

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

(Representational Image)

Specifications

Electric Tankless Hot Water Heater

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Information and product specifications contained in this document are subject to change without notice.

35

De-Ionized, Dual Module

Stainless steel and engineered plastics for all wetted components

Suffix Definitions

T2 Parallel heating elements

Specifications

Electric Tankless Hot Water Heater

MODEL NUMBER kW AMPS

RECOMMENDED

WIRE SIZE (CU)

1.0

GPM

1.5

GPM

TEMPERATURE RISE °F

2.0

GPM

3.0

GPM

4.0 GPM

T2 ONLY

VOLTS 240*

C EX144T2 DI

C EX144TC DI

C EX190T2 DI

C EX190TC DI

EX280T2T DI

VOLTS 208 Single Phase

C EX1608T2 DI

15kW

15kW

19kW

19kW

28.5kW

64(2x32)A

64(2x32)A

80(2x40)A

80(2x40)A

120(3x40)A

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

-

+

-

+

+

65°

65°

87°

87°

+

51°

51°

65°

65°

+

34°

34°

43°

43°

64°

26°

32°

48°

16.6kW

80(2x40)A 8 AWG 75° 57° 38° 28°

C EX1608TC DI

VOLTS 277

EX160T2 DI

EX160TC DI

16.6kW

16kW

80(2x40)A

58(2x29)A

8 AWG

10 AWG

+

-

75°

73°

57°

55°

38°

36°

27°

16kW 58(2x29)A 10 AWG + 73° 55° 36° –

EX200TC DI 20kW 72(2x36)A 8 AWG + 91° 68° 46° –

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

+ Temperature electrically limited to factory preset not-to-exceed temperature.

“C” indicates evaluation and compliance to Underwriters Laboratories (UL) under CAN/CSA-C22.2 No. 64/No. 88.

10.68

18.19

10.12

12.14

4.32

1.77

.94

UTLET

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

SERIES 2

EX190TC

Pg 20

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL

CONNECTION

36 Information and product specifications contained in this document are subject to change without notice.

De-Ionized, Triple Module

Three phase – 18kW to 32kW and single phase 28kW

Specifications

Electric Tankless Hot Water Heater

Applications

• Microchip manufacturing

• Pharmaceutical production

• High tolerance component cleaning

• Ultrasonic cleaning

• Spray rinse tank

• Batch chemical mixing

(Representational Image)

Quality Features

• Hot or cold water feed

• Capable of heating high purity water with state of the art materials used in construction, rated for purity levels up to

18 MEG OHM

• Proven by independent analytical laboratory to maintain water purity. Test results available upon request

• Compact size allows for easy installation close to the point-of-use

• Thermostatic temperature control available with highly accurate micro processor to deliver +/–1°F outlet accuracy

• Eliminate deadlegs. Unique flow activated design allows for constant water movement, even when not heating

• Easy installation

Product Specifications

Dimensions

Weight:

Fittings

Temp Accuracy

10 3/4”H x 5 1/4”W x 2 7/8”D

Approximately 15 lbs.

1/2” compression

+/–1° outlet accuracy

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Electrical configuration and requirements

All Eemax three phase units are custom made to order and as such, are nonreturnable and non-refundable. We urge you, therefore, to check your electrical supply, making sure all criteria for operating your Eemax water heater are met.

Eemax 208v

Three Phase Units

Delta Configuration

Requires: 3 Lives and 1 Ground (earth)

L1

L2

L3

L1

Eemax 480Y/277

Three Phase Units

Star Configuration

Requires: 3 Lives, 1 Neutral and

1 Ground (earth)

N

L2

L3

Suggested Specification

Tankless water heater shall be an Eemax De-Ionized model number EX___________.

Heating element shall be replaceable element cartridge. Unit shall be capable of heating water up to 18 MEG OHM quality or approved equal.

Enclosure to be fitted with the following features:

_____ T2T

_____ T3

_____ N4 NEMA 4 waterproof cabinet w/powder coat finish

_____ N4X NEMA 4 stainless steel waterproof corrosion- resistant cabinet

Information and product specifications contained in this document are subject to change without notice.

37

10.12

De-Ionized, Triple Module

Triple module, commercial/industrial thermostatic 3-phase heater

Suffix Definitions

T3 Parallel heating elements

Specifications

Electric Tankless Hot Water Heater

MODEL NUMBER

VOLTAGE - 208V/3 Ø Delta-no neutral leg

EX180T2T DI kW

AMPS

PER PHASE

RECOMMENDED

WIRE SIZE (CU)

2.0

GPM

TEMPERATURE RISE °F

3.0

GPM

4.0

GPM

5.0 GPM

T3 ONLY

18kW 50A/phase 6 AWG 61° 41° 31° –

EX180T3 DI

EX240T2T DI

EX240T3 DI

VOLTAGE - 240V Single Phase*

EX280T2T DI

VOLTAGE - 480Y/277V Neutral leg required

EX180T2T-277 DI

EX240T2T-277 DI

18kW

24kW

24kW

28.5kW

18kW

24kW

50A/phase

67A/phase

67A/phase

120(3x40)A

22A/phase

29A/phase

6 AWG

6 AWG

6 AWG

8 AWG

10 AWG

10 AWG

61°

82°

82°

+

61°

82°

41°

55°

55°

64°

41°

55°

31°

41°

41°

48°

31°

41°

25°

33°

EX240T3-277 DI

EX320T2T-277 DI

EX320T3-277 DI

VOLTAGE - 480V Delta

24kW

32kW

32kW

29A/phase

39A/phase

39A/phase

10 AWG

8 AWG

8 AWG

82°

+

+

55°

73°

73°

41°

55°

55°

33°

44°

ED020480T2T DI

ED024480T2T DI

20kW

24kW

24A/phase

29A/phase

10AWG

10AWG

68°

82°

46°

55°

34°

41°

ED032480T2T DI 32kW 38A/phase 6AWG 109° 73° 55° –

* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

+ Temperature electrically limited to factory preset not-to-exceed temperature.

10.68

18.19

12.14

4.32

1.77

.94

UTLET

1.41

4.00

INLET

ELECTRICAL

CONNECTION (2)

SERIES 2

EX190TC

Pg 20

1.87

.90

1.30

OUTLET

7.02

INLET

ELECTRICAL

CONNECTION

38 Information and product specifications contained in this document are subject to change without notice.

Series Six Commercial

Six module, commercial/industrial for emergency eye/face applications

Specifications

Electric Tankless Hot Water Heater

Applications

• Commercial/Industrial

• Eye/Face combo “Tepid” Water option (EF) Meets ANSI

Z358.1 “Tepid” Water Requirements for Emergency Eye/Face wash range of (65°-90°F)

• Boosters applications to 180°F (S option)

Performance Features

• Cut energy waste. Flow switch activates heater only on demand (no standby heat loss) – 99% efficient

• Save water – “Point of use application”

• Continuous hot water – no storage capacity to run out

• Factory set temperature available. Range ambient to 180°F

• Capacity to 12 GPM (T6 only), 6 GPM (T24T)

• Meets ANSI Z358.1 Tepid Water Requirements (EE)

• Reduces installation cost and material. No T&P relief valve needed (check local codes) or venting

• Thermostatic control. Microprocessor provides precise outlet temperatures

• Reduces calcification, liming and sedimentation

• Warranty – Five (5) years leaks and one (1) year on parts –

Field serviceable replaceable cartridge element, one (1) year

Optional Features

• Emergency eye/face wash. Meets ANSI tepid water requirements

• Staged heating elements. Turn on min. flow 1 GPM, max. flow 6 GPM. Sign off required

• Parallel heating elements. Turn on min. flow 3.5 GPM, max. flow 12 GPM. Sign off required

• Factory set ambient to 180°

• Sanitation 180F°

• N4, N4X (304SS) enclosures

Product Specifications

Dimensions

Weight

Cover

32 3⁄32” H x 20 3/32” W x 6 3⁄32” D

42 lbs.

Powder Coated Steel

Color Yellow

Element

Fittings

Pressure

Six replaceable cartridge elements plus two spares

1” NPT fittings at BOTTOM of unit

Min. 40 PSI, max. 150 PSI

UL Listed E86887(m)

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

For reference only.

Product will not be available after 12/31/2014.

Refer to SpecAdvantage and

SafeAdvantage product on pages 7 and 8.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Electrical configuration and requirements

All Eemax three phase units are custom made to order and as such, are nonreturnable and non-refundable. We urge you, therefore, to check your electrical supply, making sure all criteria for operating your Eemax water heater are met.

L1 Eemax 480v and 208v

Three Phase Units

Delta Configuration

Requires: 3 Lives and 1 Ground (earth)

L2

L3

Information and product specifications contained in this document are subject to change without notice.

39

Series Six Commercial

Six module, commercial/industrial for emergency eye/face applications

Suffix Definitions

T6 Parallel Heating Elements

EF Meets ANSI Z358.1 emergency eye/face wash tepid water requirements

FS Factory set ambient to 180°F

S Sanitation 180°F

MODEL NUMBER

VOLTS 208V/3 Ø

EX360T24T

EX360T6

EX480T24T

EX480T6

VOLTS 480V Delta

ED039480T24T

ED048480T24T

ED054480T24T

ED063480T24T

Specifications

Electric Tankless Hot Water Heater kW

36

36

48

48

39

48

54

63

AMPS

PER PHASE

100A/phase

100A/phase

133A/phase

133A/phase

47A/phase

58A/phase

65A/phase

76A/phase

1

1

1

1

TURN ON

(GPM)

1

3.5

1

3.5

RECOMMENDED

WIRE SIZE

4.0

GPM

5.0

GPM

1 AWG

1 AWG

2/0 AWG

2/0 AWG

6 AWG

4 AWG

4 AWG

3 AWG

61°

61°

82°

82°

67°

82°

92°

109°

53°

66°

74°

86°

49°

49°

65°

65°

44°

55°

61°

72°

TEMPERATURE RISE °F

6.0

GPM

7.5

GPM

8.0

GPM

41°

41°

54°

54°

32°

43°

30°

41°

10.0

GPM

12.0

GPM

24°

32°

-

20°

27°

For reference only.

Product will not be available after

12/31/2014.

Refer to

SpecAdvantage and

SafeAdvantage product on pages

7 and 8.

6 3/32

SERIES SIX TO PHD CROSSOVER GUIDE

BASE MODEL NUMBER KW VOLTS AMPS ° RISE AT 6 GPM

EX360T6/T24T 36 208 100 41

EX480T6/T24T

ED039480T24T

ED048480T24T

ED054480T24T

ED063480T24T

48

39

48

54

63

208

480

480

480

480

133

47

58

65

76

54

44

55

61

72

BASE MODEL NUMBER KW

AP032208

AP41208

AP54208

AP036480

AP048480

AP048480

AP054480

➠ AP054480

AP072480

32

48

54

41

54

36

48

54

72

VOLTS AMPS ° RISE AT 6 GPM

208 89 36

208

208

480

480

480

112

150

43

58

58

47

61

41

55

55

480

480

480

65

65

87

61

61

82

ELECTRICAL CONNECTIONS

32 3/32

20 3/32

40

OUTLET 1” NPT MALE

7 17/32 13 3/16

INLET 1” NPT MALE

31/32

1 1/2

-3

-4

-9

-10

-4

-5

-15

-16

-20

-21

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

-10

-12

-26

-27

Information and product specifications contained in this document are subject to change without notice.

-32

-33

Series Twelve Commercial

Twelve Module, Commercial/Industrial for Emergency Eye/Face and Drench Showers

Specifications

Electric Tankless Hot Water Heater

Applications

• Emergency combination eye/face drench shower (EFD)

• Emergency drench shower only (DS)

• Where tepid water is needed

Performance Features

• Cut energy waste. Flow switch activates heater only on demand (no standby heat loss) – 99% efficient

• Save water – “Point of use application”

• Continuous hot water – no storage capacity to run out

• Unlimited On Demand Hot Water – No delay

• Meets ANSI Z358.1 Tepid Water Requirements

• Reduces installation cost and material. No T&P relief valve needed (check local codes) or venting

• Thermostatic control. Microprocessor provides precise outlet temperatures

• Reduces calcification, liming and sedimentation

• Warranty – Five (5) years leaks and one (1) year on parts –

Field serviceable replaceable cartridge element, one (1) year

Optional Features

• Freeze protection for harsh climate, up to -30°F

• GFCI

• Safety alerting light and siren.

• N4, N4X (304SS) enclosures

Product Specifications

Dimensions

Weight

Cover

32 3/32” H x 32 3/32” W x 6” D

70 lbs.

Powder Coated Steel

Color Yellow

Element

Fittings

Pressure

Twelve replaceable cartridge elements plus two spares

1.25” NPT fittings at BOTTOM of unit

Min. 40 PSI, max. 150 PSI

UL Listed E86887(m)

U.S. Patent #’s: 4,762,980 and 4,960,976

Special Design Service

Inquiries for units for unique applications are welcome.

Call our Technical Service department at 1-800-543-6163.

For reference only.

Product will not be available after 12/31/2014.

Refer to SpecAdvantage and

SafeAdvantage product on pages 7 and 8.

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

Electrical configuration and requirements

All Eemax three phase units are custom made to order and as such, are nonreturnable and non-refundable. We urge you, therefore, to check your electrical supply, making sure all criteria for operating your Eemax water heater are met.

Eemax 600v, 480v and 208v

Three Phase Units

Delta Configuration

Requires: 3 Lives and 1 Ground (earth)

L1

L2

L3

Information and product specifications contained in this document are subject to change without notice.

41

Series Twelve Commercial

Twelve Module, Commercial/Industrial for Emergency Eye/Face and Drench Showers

Specifications

Electric Tankless Hot Water Heater

Suffix Definitions

EFD For combination Eye/Face drench shower. First Stage 3 GPM turn on (with reduced power for eye/face wash).

Second Stage 15 GPM turn on (full power for drench shower)

DS For drench shower only. (min. turn on

12 GPM)

MODEL NUMBER

VOLTS 208V/3 Ø

EX480T12 EFD

EX480T12 DS

EX720T12 EFD

EX720T12 DS

EX960T12 EFD

EX960T12 DS

VOLTS 480Y/277V

EX480T12 EFD-277*

EX580T12 EFD-277*

ED079480T12 EFD

ED096480T12 EFD

ED108480T12 EFD

ED126480T12 EFD

ED138480T12 EFD

ED150480T12 DS

VOLTS 600V Delta

C ED130600T12 EFD

C ED130600T12 DS

C ED150600T12 DS kW

48

AMPS

PER PHASE

133A/phase

48 133A/phase

TURN ON

(GPM)

3 & 15

12

72 200A/phase 3 & 15

72

96

96

48

58

79

96

200A/phase

267A/phase

267A/phase

58A/phase

76A/phase

96A/phase

116A/phase

108 130A/phase

126 152A/phase

138 166A/phase

150 180A/phase

130 130A/phase

130 130A/phase

150 145A/phase

12

3 & 15

12

3 & 15

3 & 15

3 & 15

3 & 15

3 & 15

3 & 15

3 & 15

12

3 & 15

12

12

RECOMMENDED

WIRE SIZE (CU)

2/0 AWG

2/0 AWG

200 MCM

200 MCM

400 MCM

400 MCM

6 AWG

4 AWG

1 AWG

1/0 AWG

2/0 AWG

3/0 AWG

4/0 AWG

4/0 AWG

2/0 AWG

2/0 AWG

2/0 AWG

3.0

GPM

54°

80°

108°

54°

66°

+

+

+

+

+

+

4.0

GPM

41°

61°

81°

41°

50°

67°

+

+

+

+

+

6.0

GPM

27°

40°

54°

27°

33°

44°

54°

61°

+

+

+

TEMPERATURE RISE °F

7.5

GPM

21°

32°

43°

22°

26°

35°

43°

49°

57°

62°

+

20.0

GPM

16°

16°

24°

24°

32°

32°

16°

20°

26°

32°

36°

43°

47°

51°

46°

46°

53°

* Wye – Neutral Leg Required

+ Temperature electrically limited to factory preset not-to-exceed temperature.

“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.

23.5

GPM

14°

14°

21°

21°

28°

28°

14°

17°

23°

28°

32°

37°

40°

45°

40°

40°

46°

26.0

GPM

30.0

GPM

12°

12°

18°

18°

25°

25°

12°

15°

20°

25°

28°

33°

36°

39°

35°

35°

41°

30°

30°

34°

32°

34°

For reference only.

Product will not be available after

12/31/2014.

Refer to

SpecAdvantage and

SafeAdvantage product on pages

7 and 8.

SERIES TWELVE TO PHD CROSSOVER GUIDE

BASE MODEL NUMBER KW VOLTS AMPS ° RISE AT 20 GPM

EX480T12 EFD/DS 48 208 133 16.3

EX720T12 EFD/DS

EX960T12 EFD/DS

EX480T12 EFD-277

ED079480T12 EFD

72 208 200

96

48

79

208

480/277 wye

267

58

480 96

24

32

16

26

ED096480T12 EFD 96 480 116 32

ED108480T12 EFD 108 480 130

ED126480T12 EFD 126 480 152

For assistance call technical support at 1-800-543-6163

37

43

BASE MODEL NUMBER

AP041208 EFD

AP054208 EFD

AP048480 EFD

KW

41

54

48

VOLTS AMPS ° RISE AT 20 GPM

208 112 14

208 150 18.4

AP064208 EFD 64 208 178 22

Call Technical Support at 1-800-543-6163

480 65 16

AP072480 EFD 72 480 87 25

➠ AP072480 EFD

AP108480 EFD

72

108

480

480

87

130

25

37

AP108480 EFD 108 480 130 37

AP126480 EFD 126 480 152 43

32 3/32˝

42

32 3/32˝

7 17/32˝ 13 3/16˝

31/32

1 1/2˝

OUTLET

1 1/4˝ NPT MALE

INLET

1 1/4˝ NPT MALE

Information and product specifications contained in this document are subject to change without notice.

-0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -1 -11 -1

-5

-6

-10

-11

-17

-18

-23

-24

-28

-30

-5

-6

-11

-12

Accessories and Replacement Parts

Accessories

MODEL NUMBER

EX0061-0.5AER

EX0061-1.0AER

EX145

EX176

EX177

DESCRIPTION

1/2 GPM Aerator (Male 15/16”-27, Female 55/64”-27)

1 GPM Aerator (Male 15/16”-27, Female 55/64”-27)

Element Removal Tool

3/8C X 1/2 FIP Stainless Steel Flexible Water Connector 16” Long

3/8C X 3/8 OD Stainless Steel Flexible Water Connector 16” Long

EX0183DL-30A

EX0183DL-40A

EX100S-208V

EX284AB-120-KIT

EX284AB-240-KIT

EX284AB-240ML-KIT

EX284AB-277-KIT

EX100CV-480V

EX100S-480V

EX284AB-120AM-KIT

EX284AB-240AM-KIT

EX284AB-277AM-KIT

EX284AB-277ML-KIT

TRIACS

EX18-KIT

ECO

EX08100-02

EX08100-03

EX08100-04

EX278A-KIT

EX278D-KIT

Replacement Parts – Excluding Elements

MODEL NUMBER

CIRCUIT BOARDS – RELAY TYPE

DESCRIPTION

EX0284E-309-240-KIT

EX0309-240V

240V Thermostatic Circuit Board For EX0309-240V Display Board –

HomeAdvantage/ProAdvantage

Display Board w/Push Button Temperature Control – HomeAdvantage/

ProAdvantage

208/240/277V Circuit Board Flow Control 30 Amp for units under 6.5kW

208/240/277V Circuit Board Flow Control 40 Amp for units over 6.5kW

208v/277v Dual Voltage Slave Board Readout

120V Thermostatic Circuit Board

240V Thermostatic Circuit Board

240V Thermostatic Circuit Board Multiple Lavatory

277V Thermostatic Circuit Board

480V Delta Thermostatic Control Board – Master

480V Delta Thermostatic Control Board – Slave

120V Thermostatic Circuit Board For AccuMix

240V Thermostatic Circuit Board For AccuMix

277V Thermostatic Circuit Board For AccuMix

277V Thermostatic Circuit Board For Multiple Lavatory

EX278E-KIT

Triac -all except 12kW “square” type

480V ECO – EE/EFD Temperature Range

480V ECO – Standard Temperature Rage

480V ECO – Sanitation Temperature Range

ECO – Option A – Standard Temperature Range – Standard Units

ECO – Option D – Sanitation (yellow dot) – Sanitize Units

ECO – Option E – “EE” Tepid (white dot) – Emergency Eye Wash, Face

Wash, Drench Shower

RELAYS

EX08002-01

EX250B

EX251B

EX253B

EX254B

EX259B

EX255B

EX1050-1

EX256B

EX257B

EX258

Relay-480V Delta 40a

Relay 120V 30 Amp for SP/EX2412(M), SP/EX3012(M), SP/EX3512(M)

Relay 277V 30 Amp for SP3277,SP4277,SP/EX 60, SP/EX 80

Relay 277V 40 Amp for SP/EX 60T, SP/EX 80T, SP/EX 90(T), SP/EX

100(T), EX160, EX200

Relay-208v 30a for EX/SP3208, EX/SP4208

Relay-120v 40a for EX2412T, EX3012T, EX3512T

Relay 240V 40 Amp for EX/SP 48T, SP/EX 55T, SP/EX 65T, SP/EX 75(T),

SP/EX 8208(T), SP/EX 95(T), EX120TC

Relay 208V-240V 50 Amp for EX012240T, EX023240TC,

SS012240T,SS023240TC

Relay-208v 75a for all 208 Volt 3 Phase

Relay-277v 40a for all Legacy 480 Volt 3 Phase

Relay-240v 40a EXPORT ONLY

Replacement Parts – Heating Elements

ELEMENT

CARTRIDGE MODEL NUMBER

EX144 (T2, TC)

EX190 (T2, TC)

EX023240 (T2, TC)

EX1608 (T2, TC)

EX160 (T2, TC)

EX200 (T2, TC)

SERIES THREE MODELS

EX280

SERIES FOUR MODELS

EX380

PROADVANTAGE MODELS

PA004120T

PA008208T

PA005240T

PA007240T

PA010240T

PA012240T

PA008277T

PA010277T

PA014240TC

PA016277TC

PA019240TC

PA020277TC

PA023240TC

PA028240T2T

PA018208T2T

PA024208T2T

PA018277T2T

PA024277T2T

PA032277T2T

THREE PHASE MODELS

EX180 (T3,T2T) 277V

EX180 (T3,T2T) 208V

EX240 (T3,T2T) 277V

EX240 (T3,T2T) 208V

EX320 (T3,T2T) 277V

ED020480T2T 480V

ED024480T2T 480V

ED032480T2T 480V

SINGLE POINT “SP” MODELS

SP2412

SP3012

SP3512

SP3208

SP4208

SP35

SP48

SP55

SP3277

SP4277

EX AND EX-T MODELS

EX35 (T)

EX48 (T)

EX55 (T)

EX65 (T)

EX75 (T)

EX95 (T)

EX012240 (T)

EX8208 (T)

EX4277 (T)

EX60 (T)

EX80 (T)

EX90 (T)

EX100 (T)

SERIES TWO MODELS

EX120 (T2, TC)

EX410

EX520

EX1200

EX890

EX630

EX500

EX960

EX760

EX770

EX960

EX630

EX760

EX500 PRT

EX630

EX720

EX720

EX1260

EX960

EX720

EX1650

EX1200

EX1050

EX890

EX770

EX630

EX500 PRT

EX520

EX1870

EX1280

EX960

EX850

EX760

EX610

EX480

EX410

EX1440

EX1050

EX1650

EX1200

EX1050

EX260

EX1870

EX1280

EX720

EX960

EX560

EX720

EX3454

EX2880

EX2194

EX1000

EX770

EX630

EX500 PRT

EX520

EX960

EX760

EX630

EX630

SS015240TC

SS019240TC

SS023240TC

SS029240T2T

SS038240T2T2

ACCUMIX MODELS

MT004120T

MT005240T

MT007240T

MT010240T

MT008277T

MT010277T

MB004120T

MB005240T

MB007240T

MB010240T

MB012240T

MB008277T

MB010277

MINI TANK MODELS

EMT1

EMT2.5

EMT4

EMT6

MODEL NUMBER

SERIES SIX MODELS

EX360(T6,T24T) 277V

EX360 (T6,T24T) 208V

EX480 (T6,T24T) 277V

EX480 (T6,T24T) 208V

EX540 (T6,T24T) 277V

EX630 (T6,T24T) 277V

ED039480 (T6,T24T) 480V

ED048480 (T6,T24T) 480V

ED054480 (T6,T24T) 480V

ED063480 (T6,T24T) 480V

SERIES TWELVE MODELS

EX360 (T12) 208V

EX480 (T12) 208V

EX480 (T12) 277V

EX720 (T12) 208V

EX720 (T12) 277V

EX960 (T12) 208V

EX960 (T12) 277V

EX1080 (T12) 277V

EX1260 (T12) 277V

ED079480T12 EFD 480V

ED096480T12 EFD 480V

ED108480T12 EFD 480V

ED126480T12 EFD 480V

ED138480T12 EFD 480V

ED0150480T12 DS 480V

HOMEADVANTAGE MODELS

SS012240T

ELEMENT

CARTRIDGE

EX1440

EX1080

EX1920

EX720

EX1280

EX540

EX960

EX850

EX730

EX3491

EX2880

EX2560

EX2194

EX2003

EX1840

EX1280

EX720

EX960

EX540

EX850

EX730

EX3491

EX2880

EX2560

EX2194

EX500

EX770

EX630

EX500 PRT

EX630

EX630

EX410

EX1200

EX890

EX630

EX960

EX760

EX410

EX1200

EX890

EX630

EX500 PRT

EX960

EX760

Call Eemax

Call Eemax

Call Eemax

Call Eemax

Information and product specifications contained in this document are subject to change without notice.

43

Accessories and Replacement Parts

Continued

SpecAdvantage and SafeAdvantage Replacement Parts HomeAdvantage II Replacement Parts

MODEL NUMBER

TRANSFORMERS

EX08303-07

EX08303-05

EX08303-08

EX08303-06

CIRCUIT BOARDS - PHD

EX08300-00

EX08601-00

EX78001-00

FUSES

EX198

EX08200-11

EX08200-13

EX08100-07

FLOW METER KITS

EX78000-00

FOR USE WITH

AP032208, AP041208, AP054208, AP064208

AP036480, AP048480

AP054480, AP072480, AP108480, AP126480, AP144480

AP130600, AP150600

Main Control Board - Used on all PhD products

Hall Effects Flow meter board - Used on all PhD products

Optical Sensor board assembly includes board, lens, filter, o-ring, screws

AP032208, AP054208, AP072480, AP108480

AP041208, AP064208, AP126480

AP144480, AP130600, AP150600

AP054480

AP032208, AP041208, AP054208, AP64208, AP036480, AP048480, AP054480

EX78000-01

AP064208, AP072480, AP108480, AP126480, AP144480, AP130600, AP150600

Kits include housing, board, screws, wheel, o-ring, nuts

TRIACS/RELAY

EX78002-00

EX08200-12

ELEMENTS

EX77000-8.12

EX77000-6.33

EX77000-4.81

EX77000-4.06

EX77000-9.6

EX77000-19.2

EX77000-14.4

EX77000-12.8

Triac Kit includes Triac and Board - All 208V & 480V PhD products

Relay - Used on all 600V PhD products except AP144480

AP032208 and AP144480

AP041208

AP054208

AP064208

AP144480

AP036480, AP072480

AP048480, AP150600

AP054480, AP108480

EX77000-10.97

EX77000-16.6

EMERGENCY CUT-OFF (ECO)

EX278A-KIT Used on all PhD products except EE, EFD, S

EX278D-KIT

EX278E-KIT

AP126480

AP130600

Used on PhD products with S & DB options

Used on PhD products with EE, EFD options

CONTACTORS

EX08306-02

EX08306-00

EX08309-00

AP032208, AP036480, AP054480, AP072480

AP041208, AP048480

AP054208, AP054480, AP064208, AP108480, AP126480, AP144480, AP130600,

AP150600

MODEL NUMBER

HEATING ELEMENTS

HA-P001

HA-P002

HA-P003

HA-P004

HA-P005

TRIACS

HA-P008

HA-P009

HA-P010

HA-P011

HA-P012

HA-P053

HA-P054

HA-P055

HA-P056

HA-P057

HA-P051

FLOW SENSORS

HA-P021

HA-P022

CONTROL BOARDS

HA-P024-008

HA-P024-011

HA-P024-013

HA-P025

HA-P025-024

MISC ITEMS

HA-P026

HA-P027

HA-P046

HA-P047

FOR USE WITH

Element, Heating for HA011240

Element, Heating for HA013240

Element, Heating for HA008240

Element, Heating for HA024240

Element, Heating for HA018240, HA027240, HA036240

Triac, 1st Heating Element for HA008240/HA011240/HA013240

Triac, 2nd Heating Element for HA011240/HA013240

Triac, 1st Heating Element for HA018240

Triac, 2nd Heating Element for HA018240

Triac, 3rd Heating Element for HA024240/HA027240

Triac, 1st Heating Element for HA024240, HA027240

Triac, 1st Heating Element for HA036240

Triac, 2nd Heating Element for HA024240, HA027240

Triac, 2nd Heating Element for HA036240

Triac, 3rd Heating Element for HA036240

Triac, 4th Heating Element for HA036240

Flow Sensor Assembly for HA008240/HA011240/HA013240

Flow Sensor Assembly for HA018240/HA024240/HA027240/HA036240

Control Board for HA008240 w/Transformer

Control Board for HA011240 w/Transformer

Control Board for HA013240 w/Transformer

Control Board for HA018240/HA027240/HA036240

Control Board for HA024240

Knob for HA008240/HA011240/HA013240

Knob for HA018240/HA024240/HA027240/HA036240

Thermistor for HA018240/HA024240/HA027240 (set of 2)

Thermistor for HA036240 (set of 2)

44 Information and product specifications contained in this document are subject to change without notice.

Terms and Conditions

Terms of Sale

FOB Shipping Point – Title passes to you once the product is delivered to the carrier. It is your responsibility to inspect each shipment and file a claim with the carrier for any damage or shortages.

Freight Terms

Available Options:

1. Collect – Eemax ships on your freight account #.

2. Prepaid – Eemax arranges shipping and charges you for freight.

3. Free Freight – Eemax pays freight to a single location in the continental US if your order is $2900.00 or more. (excludes SafeAdvantage and SpecAdvantage products)

Returns

Eemax will accept the return of unopened product with a 25% restock charge with prior approval. Custom products requiring sign-offs are excluded. To initiate a return, please fill out an RGA request form and email to

Eemax for approval. [email protected]

Payment Terms

Net 30 with approved credit.

Order Cancellation

All canceled product will be subject to a 25% restock fee.

How to Contact Eemax

Email: [email protected] for Tech Support,

Order Tracking, Literature and more.

Email: [email protected] for Returns

Phone: 800-543-6163

Web: www.eemax.com

LIMITED WARRANTY INFORMATION – EEMAX ELECTRIC TANKLESS WATER HEATERS

Subject to the terms and conditions set forth in this limited warranty, each eemax tankless water heater is warranted to the original owner (“owner”) against (i) mechanical or electrical failure of any component solely due to defects in materials or manufacturer’s workmanship for a period of one year from the date of original purchase and (ii) leaks solely due to defects in materials or manufacturer’s workmanship for the later of (x) five years from the date of original purchase or (y) the date of owner’s occupancy of a new dwelling in which the eemax tankless water heater is installed.

However, if owner cannot document the original date of purchase with the original sales receipt, then the limited warranty period begins on the date the eemax tankless water heater was manufactured. As owner’s sole and exclusive remedy, manufacturer shall, at manufacturer’s sole election, either repair or replace the eemax tankless water heater or the defective portion of such product. Manufacturer is not liable for any costs incurred by owner, including, without limitation, the cost of any labor. Manufacturer’s maximum liability is limited to the value of the water heater. This limited warranty shall be governed by the laws of the united states.

This limited warranty shall be the exclusive warranty made by manufacturer and is made in lieu of all other warranties, statutory, expressed or implied (whether written or oral), including, but not limited to, warranties of merchantability and fitness for a particular purpose. Manufacturer expressly disclaims the implied warranties of merchantability and fitness for a particular purpose. Owner’s sole and exclusive remedy is product repair or replaced, as provided in this limited warranty, and all other claims for damages are excluded.

The remedies set forth in this limited warranty are the only remedies available to owner or any person for breach of any covenant, duty or obligation on the part of manufacturer. Manufacturer is not liable to owner or any third party for any loss, personal injury or property damage, directly or indirectly, arising from the eemax tankless water heater. Under no circumstances is manufacturer liable to owner or any third party for incidental, consequential, special, contingent, or punitive damages of any description, whether any such claim be based upon warranty, contract, negligence, strict liability, or other tort, or otherwise.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above

limitation or exclusion may not apply to owner. In such cases, the warranty shall be limited to one year from the original date of purchase or date of manufacture, as provided in this limited warranty, or the shortest period allowed by law. This warranty gives owner specific legal rights and owner may also have other rights which may vary from state to state.

EXCLUSIONS OF COVERAGE FROM THIS LIMITED WARRANTY

1. Manufacturer is not liable for any water damage or other damages arising, directly or indirectly, from any defect in the Eemax Tankless Water Heater component part(s) or from its use.

2. Manufacturer is not liable under this limited warranty or otherwise if:

(a) The water heater or any of its component parts have been subject to misuse, alteration, neglect or accident; or

(b) The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) and/or regulation(s); or

(c) The water heater has not been installed or maintained in accordance with Manufacturer’s printed instructions, or installed with improper orientation, improper fastening, improper use of pipe dope/plumbers putty or with the use of any non Manufacturer approved sealant; or

(d) The water heater has not been continuously supplied with potable water or the water’s inlet temperature is above Manufacturer’s recommended maximum temperature; or

(e) The water heater experiences any water pressure or flow interruptions, normal inlet water pressure is outside of the published specification for the heater; is exposed to any condition that causes the heater to turn on before the air is purged from the heater, also known as a dry fire; or

(f) The water heater has been exposed to conditions resulting from floods, earthquakes, winds, fire, freezing, lightning, or circumstances beyond the Manufacturer’s control; or

(g) The water heater has been removed from its original installation location; or

(h) The water heater has been used for other than the intended purpose.

3. Owner, and not Manufacturer or its agent/representative, is liable for and shall pay for all field charges for labor or other expenses incurred in the removal and/or repair of the water heater or any expense incurred by Owner in order to repair the water heater.

Subject to the terms and conditions set forth in this limited warranty, if the Eemax Tankless Water Heater fails or leaks because of defects in materials or Manufacturer’s workmanship during the applicable warranty period set forth above,

Owner should contact Manufacturer for a Returned Merchandise Authorization (RMA). No returns will be accepted by Manufacturer without an RMA number and Manufacturer assumes no responsibility for a water heater returned without an RMA number. Water heaters should be wrapped and packaged securely to avoid shipping damage. All shipments of parts from the Manufacturer to the Owner to replace defective components shall be made via normal ground transportation. If expedited shipment is required, it will be provided at Owner’s additional cost.

LIMITED WARRANTY INFORMATION – EEMAX ELECTRIC MINI TANK WATER HEATERS

S ubject to the terms and conditions set forth in this limited warranty, each Eemax Mini Tank Water Heater is warranted to the original owner (“Owner”) against (i) mechanical or electrical failure of any component solely due to defects in materials or Manufacturer’s workmanship for a period of two years from the date of original purchase and (ii) leaks solely due to defects in materials or Manufacturer’s workmanship for the later of (x) five years from the date of original purchase or (y) the date of Owner’s occupancy of a new dwelling in which the Eemax Mini Tank Water Heater is installed. However, if Owner cannot document the original date of purchase with the original sales receipt, then the limited warranty period begins on the date the Eemax Mini Tank Water Heater was manufactured. As Owner’s sole and exclusive remedy, Manufacturer shall, at Manufacturer’s sole election, either repair or replace the Eemax Mini

Tank Water Heater or the defective portion of such product. Manufacturer is not liable for any costs incurred by Owner, including, without limitation, the cost of any labor. Manufacturer’s maximum liability is limited to the value of the water heater. This limited warranty shall be governed by the laws of the United States.

This limited warranty shall be the exclusive warranty made by manufacturer and is made in lieu of all other warranties, statutory, expressed or implied (whether written or oral), including, but not limited to, warranties of merchantability and fitness for a particular purpose. Manufacturer expressly disclaims the implied warranties of merchantability and fitness for a particular purpose. Owner’s sole and exclusive remedy is product repair or replaced, as provided in this limited warranty, and all other claims for damages are excluded.

The remedies set forth in this limited warranty are the only remedies available to owner or any person for breach of any covenant, duty or obligation on the part of manufacturer. Manufacturer is not liable to owner or any third party for any loss, personal injury or property damage, directly or indirectly, arising from the eemax mini tank water heater. Under no circumstances is manufacturer liable to owner or any third party for incidental, consequential, special, contingent, or punitive damages of any description, whether any such claim be based upon warranty, contract, negligence, strict liability, or other tort, or otherwise.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above

limitation or exclusion may not apply to owner. In such cases, the warranty shall be limited to one year from the original date of purchase or date of manufacture, as provided in this limited warranty, or the shortest period allowed by law. This warranty gives owner specific legal rights and owner may also have other rights which may vary from state to state.

EXCLUSIONS OF COVERAGE FROM THIS LIMITED WARRANTY

1. Manufacturer is not liable for any water damage or other damages arising, directly or indirectly, from any defect in the Eemax Mini Tank Water Heater component part(s) or from its use.

2. Manufacturer is not liable under this limited warranty or otherwise if:

(a) The water heater or any of its component parts have been subject to misuse, alteration, neglect or accident; or

(b) The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) and/or regulation(s); or

(c) The water heater has not been installed or maintained in accordance with Manufacturer’s printed instructions, or installed with improper orientation, improper fastening, improper use of pipe dope/plumbers putty or with the use of any non Manufacturer approved sealant; or

(d) The water heater has not been continuously supplied with potable water or the water’s inlet temperature is above Manufacturer’s recommended maximum temperature; or

(e) The water heater experiences any water pressure or flow interruptions, normal inlet water pressure is outside of the published specification for the heater; is exposed to any condition that causes the heater to turn on before the air is purged from the heater also know as dry fire; or

(f) The water heater has been exposed to conditions resulting from floods, earthquakes, winds, fire, freezing, lightning, or circumstances beyond the Manufacturer’s control; or

(g) The water heater has been removed from its original installation location; or

(h) The water heater has been used for other than the intended purpose.

3. Owner, and not Manufacturer or its agent/representative, is liable for and shall pay for all field charges for labor or other expenses incurred in the removal and/or repair of the water heater or any expense incurred by Owner in order to repair the water heater.

Subject to the terms and conditions set forth in this limited warranty, if the Eemax Mini Tank Water Heater fails or leaks because of defects in materials or Manufacturer’s workmanship during the applicable warranty period set forth above,

Owner should contact Manufacturer for a Returned Merchandise Authorization (RMA). No returns will be accepted by Manufacturer without an RMA number and Manufacturer assumes no responsibility for a water heater returned without an RMA number. Water heaters should be wrapped and packaged securely to avoid shipping damage. All shipments of parts from the Manufacturer to the Owner to replace defective components shall be made via normal ground transportation. If expedited shipment is required, it will be provided at Owner’s additional cost.

Information and product specifications contained in this document are subject to change without notice.

45

Notes

46 Information and product specifications contained in this document are subject to change without notice.

Notes

Information and product specifications contained in this document are subject to change without notice.

47

To learn more about the full line of Eemax Water Heaters scan the

QR code or visit eemax.com

400 Captain Neville Drive

Waterbury, CT 06705

(800) 543-6163 [email protected]

eemax.com

The wetted surface of this product contacted by water contains less than 0.25% lead and meets ANSI/NSF 372

NOTE: Certifications may vary based on product lines

© 2015 Eemax, Inc.

All Rights Reserved. EEM6010

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement