Molded Vacuum Recloser
The Elastimold
®
Recloser, in either single-phase or threephase configurations, is fully compatible with SEL
®
Controls
Smart, Light and Flexible
The Elastimold ® Recloser is world-class, by design. It responds to every hardware requirement that utilities want.
Smart – Our recloser is Smart Grid ready with three integral load-side voltage sensors and provision to add source-side voltage sensors, if desired. It was designed to be fully compatible with the industry’s
No. 1 name in controls, Schweitzer Engineering Laboratories.
Light – The three-phase Elastimold ® Recloser weighs 33% less than existing typical units. The simplicity of the mechanism design, and the compactness of the encapsulated components, contribute to making the
Elastimold ® Recloser easier to move and install.
Flexible – The Elastimold ® Recloser is modular, so field upgrades and retrofits are easy and fast. The single phase recloser has a pole rotation mounting bracket for easier installation.
Made with Your Needs in Mind – We designed the Elastimold ® Recloser only after extensive talks with electric utilities. Its features, from easier-to-see open/close indicators to the many robust extra features that we consider “standard”, are there because of you.
A86
Solid Dielectric Insulation
Lifting Rings
Highly-Visible
360° Indicators
Current & Voltage
Sensors
Integrated Pole
Mounting Bracket
Manual Tripping Lever
Recloser Operation
The Elastimold ® Molded Vacuum Recloser (MVR) operates electrically by energizing a magnetic actuator system with a completely sealed housing. Each pole contains a vacuum interrupter sealed in solid dielectric insulation for mechanical and high dielectric strength.
An open-closed position indicator provides a 360-degree view. An external manual trip assembly is located on the side; when in the down position, it maintains the recloser in a lockout position until it is manually restored. All electrical control connections are made through a sealed single-environment control cable connector on the side.
The combination of the molded vacuum recloser with microprocessor controls accurately detects a wide range of line disturbances and provides reliable, high-speed isolation for adverse conditions.
Current Transformer
Side Silicone Terminal
Load Side Voltage Sensor
Upper Cover
Lower Cover
Top Silicone Sheds
Vacuum Bottle
Main Body EPDM
Insulation
Solid Dielectric
Diaphragm
Pull Rod Assembly
Bottom Silicone Sheds
Magnetic Actuator
Position Indicator w w w . t n b . c a
Elastimold
®
Cable Accessories
Molded Vacuum Recloser
Catalogue Numbering System
Indicates field that must be filled in to complete order.
M V R
1
3
Phases
Single-Phase
Three-Phase
15
27
38
Voltage Class
15.0 kV
27.0 kV
38.0 kV
1
2
3
Control Model
SEL-351R, SEL-351R Falcon ™ (14-pin)
SEL-651R (32-pin)
SEL-351RS Kestrel ® (single-phase only)
Sequential Numbers*
Control, Cable Length and
Other Accessories
12
—
Interrupting Rating
25 kV
Future
Source-Side Voltage Sensing
N
1
3
No
One Voltage Sensor
Three Voltage Sensors
* Consult your T&B sales representative for complete catalogue number configuration.
SEL is a registered trademark of Schweitzer
Engineering Laboratories, Inc.
Accessories
Cat. No.
3188D0120G1
3188D0121G1
3188C0122G1
3188C0123G1
3070A1191P1
3070A1190P1
3188C0075G1
3188D0119G1
3188B0126G1
3180A0661P1
3070B0913G1
1548FH-ANC3JNAA
1548FH-ANC3XNA1
Description
Three-phase Line Side Arrester Frame
Three-phase Load Side Arrester Frame
Single-phase Line Side Arrester Frame
Single-phase Load Side Arrester Frame
Wildlife Protector Top Bushing (one per phase)
Wildlife Protector Side Bushing (one per phase)
Source-side Voltage Sensors (one per phase)
Substation Mounting Frame
NEMA 2-hole pad
NEMA 4-hole pad
Aerial Lug
Fisher Pierce ® Overhead Faulted Circuit Indicator – Adaptive Trip TM ; 4 hr automatic reset time with current reset override
(60 sec. after restoration of power), five ultra-bright LEDs for increase visibility display
Fisher Pierce ® Overhead Faulted Circuit Indicator – Adaptive Trip TM ; 4 hr automatic reset time with current reset override
(60 sec. after restoration of power), with 4 hr temporary fault reset time, temporary fault indication option, four red and one amber LED
Ratings and Specifications
15 kV 27 kV 38 kV* 15 kV 27 kV 38 kV*
Nominal System Voltage (kV RMS)
Rated Maximum Voltage (kV RMS)
Nominal Frequency (Hz)
Phase Spacing on Three-Phase Units (Inches)
BIL (kV)
Power Frequency Withstand — Dry (kV)
Power Frequency Withstand — Wet (kV)
Continuous Current (A RMS)
14.4
17.1
50 or 60
15.5
150
50
45
800
25
29.3
50 or 60
15.5
150
50
45
800
35
38
50 or 60
15.5
170
70
60
800
Interrupting Current (kA RMS Symmetrical)
Making Current (kA Asymmetrical Peak)
Creepage Distances (Inches — Line to Ground)
Arc-Extinction Medium
Insulation Medium
Mechanical Operations
Operating Temperatures
Voltage Sensor Accuracy (Load/Line)
12.5
32.5
41.5
Vacuum
EPDM/Silicon Rubber
10,000
–40°C to 65°C
3% / 1%
Eight (8) Hour Overload Current (A RMS) 960 960 960 CT Accuracy Class 1
CT Ratio 1,000 to 1 1,000 to 1 1,000 to 1 Weight (Single–Phase/Three-Phase) 57 lb. / 208 lb.
* Single phase 38 kV units are rated for use on grounded systems only. Three-phase 38 kV units can be used for single-phase tripping on grounded systems only.
For ungrounded systems, three-phase tripping is required.
12.5
32.5
41.5
Vacuum
EPDM/Silicon Rubber
10,000
–40°C to 65°C
3% / 1%
Class 1
57 lb. / 208 lb.
12.5
32.5
41.5
Vacuum
EPDM/Silicon Rubber
10,000
–40°C to 65°C
3% / 1%