- Home
- Domestic appliances
- Climate control
- Split-system air conditioners
- Mitsubishi
- PLA-AA
- User manual
advertisement
▼
Scroll to page 2
of 90
OCS05A-1.qxp 06.5.15 0:50 PM Page 1 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS May 2006 TECHNICAL DATA BOOK R410A <Indoor unit> [Model names] INVERTER PLA-RP·AA PLA-RP·AA2 PEAD-RP·EA PEAD-RP·EA2 PEAD-RP·GA PKA-RP·GAL PKA-RP·FAL PCA-RP·GA PCA-RP·HA PSA-RP·GA No. OCS05 REVISED EDITION-A Revision: • High dimension of PEAD-RP71EA are modified in REVISED EDITION-A. • Some descriptions have been modified. • Please void OCS05. <Outdoor unit> [Model names] PUHZ-RP35/50/60/71/100/125/140VHA2 PUHZ-RP100/125/140YHA2 CONTENTS 1. REFERENCE SERVICE MANUAL·············································2 2. SPECIFICATIONS ······································································3 3. OUTLINES AND DIMENSIONS················································23 4. WIRING DIAGRAM···································································42 5. REFRIGERANT SYSTEM DIAGRAM ······································54 6. PERFORMANCE CURVES ······················································57 7. CORRECTION FACTORS ························································59 8. APPLICABLE EXTENSION PIPE FOR EACH MODEL ··········60 9. AIR FLOW DATA ······································································64 10. NOISE CRITERION CURVES ··················································78 11. OPTIONAL PARTS·····································································88 kW Model OCS05A-1.qxp 1 06.5.15 0:50 PM Page 2 REFERENCE SERVICE MANUAL For information on service, please refer to the service manual as follows. 1-1. INDOOR UNIT Model name Service Ref. PLA-RP35/50/60/71AA.UK PLA-RP35/50/60/71AA Service Manual No. OC335 PLA-RP35/50/60/71AA OC327 PLA-RP100/125/140AA2 PLA-RP100/125/140AA2.UK OC357 PCA-RP50/60/71GA PCA-RP100/125/140GA PCA-RP71/125HA PCA-RP50/60/71GA PCA-RP100/125/140GA PCA-RP71/125HA OC328 OC329 PKA-RP35/50GAL PKA-RP35/50GAL OC330 PKA-RP60/71/100FAL PKA-RP60/71/100FAL OC331 PSA-RP71/100/125/140GA PSA-RP71/100/125/140GA OC332 PEAD-RP50/60/71/125/140EA PEAD-RP35/100EA2 PEAD-RP60/71/100GA PEAD-RP50/60/71/125/140EA.UK PEAD-RP35/100EA2.UK PEAD-RP60/71/100GA.UK HWE05210 HWE05060 1-2. OUTDOOR UNIT Model name Service Ref. PUHZ-RP35/50/60/71VHA2 PUHZ-RP100/125/140VHA2 PUHZ-RP100/125/140YHA2 PUHZ-RP35/50/60/71VHA2 PUHZ-RP100/125/140VHA2 PUHZ-RP100/125/140YHA2 2 Service Manual No. OC374 OCS05A-1.qxp 06.5.15 0:50 PM Page 3 SPECIFICATIONS 2 2-1. CEILING CASSETTE TYPE Model name Indoor unit PLA-RP35AA PLA-RP50AA Btu/h PUHZ-RP35VHA2 12,300 PUHZ-RP50VHA2 17,100 kW 3.6(1.6-4.5) 5.0(2.3-5.6) kW 1.07 1.55 3.36 3.23 Outdoor unit Cooling Capacity Total input EER Energy label class A A Btu/h 0.89 14,000 0.86 20,500 kW 4.1(1.6-5.2) 6.0(2.5-7.3) kW 1.12 1.62 3.66 3.70 A A SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW [ Cycle Hz 50 V 230 Breaker size A 11-12-13-14 14-15-16-18 CFM 390-425-460-495 495-530-565-635 External pressure Pa dB(A) 0 0 27-28-29-31 28-29-31-33 W : mm D : mm H : mm W : inch D : inch Unit (Panel) lbs 53 (11) mm 32 inch 1-1/4 Air flow CMM 35 1,240 Sound level at cooling CFM dB(A) Sound level at heating dB(A) 44 46 Ivory Munsell 3Y 7.8/1.1 W : mm 800 D : mm 300+23 H : mm 600 W : inch 31-1/2 D : inch 11-13/16 + 7/8 H : inch 23-5/8 kg 45 Weight Gas side O.D. Liquid side O.D. lbs 99 mm 12.7 inch 1/2 mm 6.35 inch 1/4 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit 33-1/16 (37-3/8) 33-1/16 (37-3/8) Unit drain pipe I.D. Dimension Cooling 840 (950) 258 (30) 10-3/16 (1-3/16) 24 (5) External finish NOTE: White Munsell 0.70Y 8.59/0.97 840 (950) kg H : inch Weight Refrigerant pipe length 16 CMM Dimension Unit (Panel) Refrigerant pipe size 1 Air flow (Low-Medium2-Medium1-High) Sound level (Low-Medium2-Medium1-High) External finish (Panel) Outdoor unit - Phase Voltage Indoor unit - Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 3 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 4 Indoor unit PLA-RP60AA PLA-RP71AA Btu/h PUHZ-RP60VHA2 20,500 PUHZ-RP71VHA2 24,200 kW 6.0(2.7-6.7) 7.1(3.3-8.1) kW 1.65 1.97 3.64 3.60 Outdoor unit Cooling Capacity Total input EER Energy label class A A Btu/h 0.78 23,900 0.74 27,300 kW 7.0(2.8-8.2) 8.0(3.5-10.2) kW 1.85 2.34 3.78 3.42 A B SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW [ Cycle Hz 50 V 230 Breaker size 1 A 25 Air flow (Low-Medium2-Medium1-High) CMM 14-15-16-18 15-16-18-20 CFM 495-530-565-635 530-565-635-705 External pressure Pa dB(A) 0 0 28-29-31-33 28-30-32-34 Sound level (Low-Medium2-Medium1-High) External finish (Panel) Dimension Unit (Panel) W : mm D : mm H : mm W : inch D : inch Unit (Panel) lbs 53 (11) mm 32 inch 1-1/4 Air flow CMM 55 1,940 Sound level at cooling CFM dB(A) Sound level at heating dB(A) Weight Gas side O.D. Liquid side O.D. NOTE: Upper limit Lower limit Upper limit Heating Lower limit 47 48 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 943 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch 37-1/8 kg 75 lbs 165 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 33-1/16 (37-3/8) 33-1/16 (37-3/8) Unit drain pipe I.D. Dimension Refrigerant pipe length 840 (950) 258 (30) 10-3/16 (1-3/16) 24 (5) External finish Refrigerant pipe size White Munsell 0.70Y 8.59/0.97 840 (950) kg H : inch Weight Outdoor unit - Phase Voltage Indoor unit - Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 4 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 5 Indoor unit PLA-RP100AA2 PLA-RP125AA2 PLA-RP140AA2 Btu/h PUHZ-RP100VHA2 34,100 PUHZ-RP125VHA2 42,700 PUHZ-RP140VHA2 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(5.5-15.3) kW 3.02 3.87 4.65 3.31 3.23 3.01 Outdoor unit Cooling Capacity Total input EER Energy label class A A B Btu/h 0.78 38,200 0.74 47,800 0.71 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.02 3.88 4.69 3.61 3.61 3.41 A A B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 32 CMM 19-21-23-27 24-25-27-30 CFM 670-740-810-950 850-880-950-1060 External pressure Pa dB(A) 0 0 33-36-39-41 37-40-43-45 Sound level (Low-Medium2-Medium1-High) External finish (Panel) Dimension Unit (Panel) White Munsell 0.70Y 8.59/0.97 840 (950) W : mm 840 (950) 298 (30) D : mm H : mm 33-1/16 (37-3/8) 33-1/16 (37-3/8) W : inch D : inch kg 11-3/4 (1-3/16) 32 (5) Unit (Panel) lbs 71 (11) Unit drain pipe I.D. mm 32 inch 1-1/4 Air flow CMM 100 3,530 Sound level at cooling CFM dB(A) 49 Sound level at heating dB(A) 51 H : inch Weight Outdoor unit 40 Air flow (Low-Medium2-Medium1-High) External finish Dimension 50 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 121 116 lbs 267 256 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 53-1/8 kg Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46: D.B. 19˚C, W.B. 15˚C D.B. -5: w D.B. 21:, W.B. 15: D.B. 28˚C D.B. -20:, W.B. -20: D.B. 17˚C 5 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 6 Indoor unit PLA-RP100AA2 PLA-RP125AA2 PLA-RP140AA2 Btu/h PUHZ-RP100YHA2 34,100 PUHZ-RP125YHA2 42,700 PUHZ-RP140YHA2 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(5.5-15.3) kW 3.02 3.87 4.65 3.31 3.23 3.01 Outdoor unit Cooling Capacity Total input EER Energy label class A A B Btu/h 0.78 38,200 0.74 47,800 0.71 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.02 3.88 4.69 3.61 3.61 3.41 A A B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A 16 Air flow (Low-Medium2-Medium1-High) CMM 19-21-23-27 24-25-27-30 CFM 670-740-810-950 850-880-950-1060 External pressure Pa dB(A) 0 0 33-36-39-41 37-40-43-45 Sound level (Low-Medium2-Medium1-High) External finish (Panel) Dimension Unit (Panel) White Munsell 0.70Y 8.59/0.97 840 (950) W : mm 840 (950) 298 (30) D : mm H : mm 33-1/16 (37-3/8) 33-1/16 (37-3/8) W : inch D : inch kg 11-3/4 (1-3/16) 32 (5) Unit (Panel) lbs 71 (11) Unit drain pipe I.D. mm 32 inch 1-1/4 Air flow CMM 100 3,530 Sound level at cooling CFM dB(A) 49 Sound level at heating dB(A) 51 H : inch Weight Outdoor unit External finish Dimension 50 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 135 130 lbs 298 287 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 53-1/8 kg Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -20˚C, W.B. -20˚C D.B. 17˚C 6 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Page 7 2-2. CEILING-CONCEALED TYPE Model name Indoor unit PEAD-RP35EA2 PEAD-RP50EA Btu/h PUHZ-RP35VHA2 12,300 PUHZ-RP50VHA2 16,700 kW 3.6(1.6-4.5) 4.9(2.3-5.6) kW 1.12 1.52 3.21 3.22 Outdoor unit Cooling Capacity Total input EER Energy label class A A Btu/h 0.89 14,000 0.82 20,500 kW 4.1(1.6-5.2) 6.0(2.5-7.3) kW 1.20 1.65 3.41 3.64 B A SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW - Phase [ Cycle Hz 50 V 230 Voltage Breaker size Indoor unit 1 A 16 Air flow (Low-High) CMM 13.5-17 CFM External pressure Pa dB(A) 476-600 30(70) Sound level (Low-High) 36-40 (70Pa : 38-44) External finish Dimension Galvanized sheets W : mm 935 D : mm 700 H : mm 295 W : inch 36-13/16 D : inch 27-5/8 H : inch Weight 33 lbs 73 Air flow CMM Sound level at cooling CFM dB(A) Sound level at heating dB(A) External finish Dimension NOTE: Upper limit Lower limit Upper limit Heating Lower limit 44 46 800 D : mm 300+23 H : mm 600 W : inch 31-1/2 D : inch 11-13/16 + 7/8 H : inch 23-5/8 kg 45 Gas side O.D. lbs 99 mm 12.7 inch 1/2 mm 6.35 inch 1/4 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 35 1,240 W : mm Liquid side O.D. Refrigerant pipe length 77 Ivory Munsell 3Y 7.8/1.1 Weight Refrigerant pipe size 35 R1(External thread) Unit drain pipe Outdoor unit 11-5/8 kg Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 7 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 8 Indoor unit PEAD-RP60EA PEAD-RP71EA Btu/h PUHZ-RP60VHA2 20,500 PUHZ-RP71VHA2 24,200 kW 6.0(2.7-6.7) 7.1(3.3-8.1) kW 1.86 2.15 3.23 3.30 Outdoor unit Cooling Capacity Total input EER Energy label class A A Btu/h 0.79 23,900 0.83 27,300 kW 7.0(2.8-8.2) 8.0(3.5-10.2) kW 1.90 2.34 3.68 3.42 A B SHF Heating Capacity Total input COP Energy label class Booster heater Power supply - - Phase [ Cycle Hz 50 V 230 Voltage Breaker size Indoor unit kW Air flow (Low-High) External pressure Sound level (Low-High) 1 A 25 CMM 17-21 20-25 CFM 600-741 30(70) 706-883 70(130) 37-41 (70Pa : 39-46) 37-41 (130Pa : 40-45) Pa dB(A) External finish Dimension Galvanized sheets W : mm 1175 D : mm 700 H : mm 295 740 325 W : inch 46-1/8 D : inch Weight 27-5/8 H : inch 11-5/8 12-13/16 kg 42 44 lbs 92 Outdoor unit Air flow CMM Sound level at cooling CFM dB(A) Sound level at heating dB(A) External finish Dimension Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Upper limit Lower limit Upper limit Heating Lower limit 55 1,940 55 1,940 47 47 48 48 Ivory Munsell 3Y 7.8/1.1 W : mm 950 950 D : mm 330+30 330+30 H : mm 943 943 W : inch 37-3/8 37-3/8 D : inch 13 + 1-3/16 13 + 1-3/16 H : inch 37-1/8 37-1/8 kg 75 75 lbs 165 165 15.88 mm 15.88 inch 5/8 5/8 mm 9.52 9.52 inch 3/8 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 97 R1(External thread) Unit drain pipe Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 8 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 9 Indoor unit PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA Btu/h PUHZ-RP100VHA2 34,100 PUHZ-RP125VHA2 42,700 PUHZ-RP140VHA2 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(5.5-15.3) kW 3.06 3.89 4.65 3.27 3.21 3.01 Outdoor unit Cooling Capacity Total input EER Energy label class A A B Btu/h 0.86 38,200 0.82 47,800 0.83 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.19 3.88 4.69 3.51 3.61 3.41 B A B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 32 40 Air flow (Low-High) CMM 33.5-42 36.5-46 CFM 1183-1483 External pressure Pa dB(A) Sound level (Low-High) 44-50 (130Pa : 46-52) External finish Dimension 1288-1624 70(130) 46-51 (130Pa : 47-53) Galvanized sheets W : mm 1415 1715 D : mm 740 H : mm 325 W : inch 55-11/16 67-1/2 D : inch 29-1/8 H : inch Weight 12-13/16 kg 65 70 lbs 143 154 R1(External thread) Unit drain pipe Outdoor unit Air flow CMM Sound level at cooling CFM dB(A) 100 3,530 49 Sound level at heating dB(A) 51 External finish Dimension 50 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 121 116 lbs 267 256 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 53-1/8 kg Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46: D.B. 19˚C, W.B. 15˚C D.B. -5: w D.B. 21:, W.B. 15: D.B. 28˚C D.B. -20:, W.B. -20: D.B. 17˚C 9 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 10 Indoor unit PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA Btu/h PUHZ-RP100YHA2 34,100 PUHZ-RP125YHA2 42,700 PUHZ-RP140YHA2 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(5.5-15.3) kW 3.06 3.89 4.65 3.27 3.21 3.01 Outdoor unit Cooling Capacity Total input EER Energy label class A A B Btu/h 0.86 38,200 0.82 47,800 0.83 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.19 3.88 4.69 3.51 3.61 3.41 B A B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A 16 Air flow (Low-High) CMM 33.5-42 36.5-46 CFM 1183-1483 1288-1624 External pressure Pa dB(A) 44-50 Sound level (Low-High) 70(130) External finish Dimension 46-51 (130Pa : 47-53) (130Pa : 46-52) Galvanized sheets W : mm 1415 1715 D : mm 740 H : mm 325 W : inch 55-11/16 67-1/2 D : inch 29-1/8 H : inch Weight 12-13/16 kg 65 70 lbs 143 154 R1(External thread) Unit drain pipe Outdoor unit Air flow CMM Sound level at cooling CFM dB(A) 100 3,530 49 Sound level at heating dB(A) 51 External finish Dimension 50 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 135 130 lbs 298 287 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 53-1/8 kg Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -20˚C, W.B. -20˚C D.B. 17˚C 10 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 11 Indoor unit PEAD-RP60GA PEAD-RP71GA PEAD-RP100GA Btu/h PUHZ-RP60VHA2 20,500 PUHZ-RP71VHA2 24,200 PUHZ-RP100VHA2 34,100 kW 6.0(2.7-6.7) 7.1(3.3-8.1) 10.0(4.9-11.4) kW 1.68 2.15 3.08 3.57 3.30 3.25 Outdoor unit Cooling Capacity Total input EER Energy label class A A A Btu/h 0.88 23,900 0.83 27,300 0.86 38,200 kW 7.0(2.8-8.2) 8.0(3.5-10.2) 11.0(4.5-14.0) kW 1.77 2.34 3.23 3.95 3.42 3.41 A B B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 25 Air flow (Low-High) CMM 16.5-21 CFM 582-741 External pressure Pa dB(A) Sound level (Low-High) 26.5-33 706-883 935-1165 35-38/37-41/37-43 (10/50/70Pa) 40-43/42-45/42-46 (10/50/70Pa) 10/50/70 33-37/35-40/36-42 (10/50/70Pa) External finish Dimension 32 20-25 10/50/70 Galvanized sheets W : mm 1171 1411 D : mm 740 H : mm W : inch 275 46-1/8 55-9/16 D : inch 29-1/8 H : inch Weight Unit drain pipe O.D. Outdoor unit 42 50 lbs 93 111 mm 32 inch 1-1/4 Air flow CMM Sound level at cooling CFM dB(A) Sound level at heating dB(A) External finish Dimension 10-13/16 kg 55 1,940 100 3,530 47 49 48 51 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 943 1350 W : inch 37-3/8 D : inch 37-1/8 kg 75 121 lbs 165 267 Weight Refrigerant pipe size 13 + 1-3/16 H : inch Gas side O.D. mm Liquid side O.D. 15.88 inch 5/8 mm 9.52 inch Refrigerant pipe length NOTE: 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 53-1/8 Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C D.B. 28˚C D.B. 17˚C Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Outdoor D.B. 46˚C D.B. -5˚C w1 D.B. 21˚C, W.B. 15˚C D.B. -11˚C, W.B. -12˚C w2 11 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w1. If optional Air protect guide installed. D.B.-15: w2. For RP100 D.B. -20:, W.B. -20: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 12 Indoor unit PEAD-RP100GA Outdoor unit Cooling Capacity Total input Btu/h PUHZ-RP100YHA2 34,100 kW 10.0(4.9-11.4) kW 3.08 EER 3.25 Energy label class A SHF Heating Capacity Total input Btu/h 0.86 38,200 kW 11.0(4.5-14.0) kW 3.23 COP 3.41 Energy label class Booster heater Power supply - Phase [ 3 Cycle Hz 50 V 400 Voltage Breaker size Indoor unit B kW A 16 Air flow (Low-High) CMM 26.5-33 CFM 935-1165 External pressure Pa dB(A) Sound level (Low-High) 10/50/70 40-43/42-45/42-46 (10/50/70Pa) External finish Dimension Weight Unit drain pipe O.D. Outdoor unit Galvanized sheets W : mm 1411 D : mm 740 H : mm 275 W : inch 55-9/16 D : inch 29-1/8 H : inch 10-13/16 kg 50 lbs 111 mm 32 inch 1-1/4 Air flow CMM 100 3,530 Sound level at cooling CFM dB(A) Sound level at heating dB(A) 49 51 External finish Dimension Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Upper limit Lower limit Upper limit Heating Lower limit W : mm 943 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch 53-1/8 kg 135 lbs 298 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling Ivory Munsell 3Y 7.8/1.1 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -20˚C, W.B. -20˚C D.B. 17˚C 12 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Page 13 2-3. WALL MOUNTED TYPE Model name Indoor unit PKA-RP35GAL PKA-RP50GAL Btu/h PUHZ-RP35VHA2 12,300 PUHZ-RP50VHA2 15,700 kW 3.6(1.6-4.5) 4.6(2.3-5.4) kW 1.03 1.63 3.50 2.82 Outdoor unit Cooling Capacity Total input EER Energy label class A C Btu/h 0.84 14,000 0.74 15,400 kW 4.1(1.6-5.2) 4.5(2.5-6.2) kW 1.27 1.40 3.23 3.21 C C SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW [ Cycle Hz 50 V 230 Breaker size A 16 CMM 9-10-11-12 CFM 320-355-390-425 External pressure Pa dB(A) 36-38-41-43 External finish Dimension White Munsell 0.70Y 8.59/0.97 990 D : mm 235 H : mm 340 W : inch 39 D : inch 9-1/4 H : inch 13-3/8 kg 16 Unit drain pipe O.D. lbs 35 mm 20 inch 13/16 Air flow CMM 35 1,240 Sound level at cooling CFM dB(A) Sound level at heating dB(A) External finish Dimension 800 D : mm 300+23 H : mm 600 W : inch 31-1/2 D : inch 11-13/16 + 7/8 H : inch 23-5/8 kg 45 Gas side O.D. Upper limit Lower limit Upper limit Heating Lower limit lbs 99 mm 12.7 inch 1/2 mm 6.35 inch 1/4 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 46 W : mm Liquid side O.D. NOTE: 44 Ivory Munsell 3Y 7.8/1.1 Weight Refrigerant pipe length 0 W : mm Weight Refrigerant pipe size 1 Air flow (Low-Medium2-Medium1-High) Sound level (Low-Medium2-Medium1-High) Outdoor unit - Phase Voltage Indoor unit - Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 13 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 14 Indoor unit PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL Btu/h PUHZ-RP60VHA2 20,500 PUHZ-RP71VHA2 24,200 PUHZ-RP100VHA2 34,100 kW 6.0(2.7-6.7) 7.1(3.3-8.1) 10.0(4.9-11.4) kW 1.55 1.98 2.93 3.87 3.59 3.41 A A A Btu/h 0.83 23,900 0.77 27,300 0.77 38,200 kW 7.0(2.8-8.2) 7.6(3.5-10.2) 11.2(4.5-14.0) kW 2.01 2.23 3.25 3.48 3.41 3.45 B B B - - - Outdoor unit Cooling Capacity Total input EER Energy label class SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 V 230 Voltage Breaker size Indoor unit 1 A 25 32 Air flow (Low-High) CMM 15-20 22-28 CFM 530-705 External pressure Pa dB(A) 39-45 W : mm 1400 Sound level (Low-High) External finish Dimension 780-990 0 41-46 Munsell 3.4Y 7.7/0.8 1680 D : mm 235 H : mm 340 W : inch 55-1/8 D : inch H : inch Weight Unit drain pipe O.D. 13-3/8 kg 24 lbs 53 Air flow CMM Sound level at cooling CFM dB(A) Sound level at heating dB(A) 13/16 55 1,940 47 49 51 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 943 Gas side O.D. Liquid side O.D. 1350 37-3/8 D : inch Refrigerant pipe size 100 3,530 48 W : inch Weight 62 20 External finish Dimension 28 mm inch Outdoor unit 66-1/8 9-1/4 13 + 1-3/16 H : inch 37-1/8 53-1/8 kg 75 121 lbs 165 mm 267 15.88 inch 5/8 mm 9.52 inch Refrigerant pipe length NOTE: m Max. 30 Max. 30 Length m Max. 50 Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 3/8 Height difference Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C D.B. 28˚C D.B. 17˚C Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Outdoor D.B. 46˚C D.B. -5˚C w1 D.B. 21˚C, W.B. 15˚C D.B. -11˚C, W.B. -12˚C w2 14 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w1. If optional Air protect guide installed. D.B.-15: w2. For RP100 D.B. -20:, W.B. -20: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 15 Indoor unit PKA-RP100FAL Outdoor unit Cooling Capacity Total input Btu/h PUHZ-RP100YHA2 34,100 kW 10.0(4.9-11.4) kW 2.93 EER 3.41 Energy label class A SHF Heating Capacity Total input Btu/h 0.77 38,200 kW 11.2(4.5-14.0) kW 3.25 COP 3.45 Energy label class Booster heater Power supply - Phase [ 3 Cycle Hz 50 V 400 Voltage Breaker size Indoor unit B kW A 16 Air flow (Low-High) CMM 22-28 CFM 780-990 External pressure Pa dB(A) 41-46 Sound level (Low-High) External finish Dimension Weight Unit drain pipe O.D. Outdoor unit Munsell 3.4Y 7.7/0.8 W : mm 1680 D : mm 235 H : mm 340 W : inch 66-1/8 D : inch 9-1/4 H : inch 13-3/8 kg 28 lbs 62 mm 20 inch 13/16 Air flow CMM 100 3,530 Sound level at cooling CFM dB(A) Sound level at heating dB(A) External finish Dimension Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 49 51 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch 53-1/8 kg 135 lbs 298 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 0 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -20˚C, W.B. -20˚C D.B. 17˚C 15 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Page 16 2-4. CEILING SUSPENDED TYPE Model name Indoor unit PCA-RP50GA PCA-RP60GA PCA-RP71GA Btu/h PUHZ-RP50VHA2 16,000 PUHZ-RP60VHA2 20,500 PUHZ-RP71VHA2 24,200 kW 4.7(2.3-5.4) 6.0(2.7-6.7) 7.1(3.3-8.1) kW 1.67 1.63 2.14 2.81 3.68 3.32 Outdoor unit Cooling Capacity Total input EER Energy label class C A A Btu/h 0.76 18,800 0.86 23,900 0.74 27,300 kW 5.5(2.5-6.6) 7.0(2.8-8.2) 7.6(3.5-10.2) kW 1.71 2.03 2.23 3.22 3.45 3.41 C B B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 16 25 Air flow CMM 10-11-12-13 14-15-16-18 (Low-Medium2-Medium1-High) External pressure CFM 355-390-425-460 495-530-565-635 Pa dB(A) 0 0 37-38-40-42 37-39-41-43 W : mm 1000 Sound level (Low-Medium2-Medium1-High) External finish Dimension White Munsell 0.70Y 8.59/0.97 1310 D : mm 680 H : mm 210 W : inch 39-3/8 51-9/16 D : inch 26-3/4 H : inch Weight Unit drain pipe I.D. 8-1/4 kg 27 34 lbs 60 75 mm 26 inch Outdoor unit Air flow CMM Sound level at cooling CFM dB(A) Sound level at heating dB(A) 1 35 1,240 55 1,940 44 47 46 External finish Dimension W : mm 800 950 D : mm 300+23 330+30 H : mm 600 943 W : inch 31-1/2 37-3/8 D : inch 11-13/16 + 7/8 13 + 1-3/16 H : inch 23-5/8 37-1/8 kg 45 75 lbs 99 165 15.88 Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: mm 12.7 inch 1/2 5/8 mm 6.35 9.52 inch 1/4 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 48 Ivory Munsell 3Y 7.8/1.1 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 16 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 17 Indoor unit PCA-RP100GA PCA-RP125GA PCA-RP140GA Btu/h PUHZ-RP100VHA2 34,100 PUHZ-RP125VHA2 42,700 PUHZ-RP140VHA2 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(5.5-15.3) kW 2.92 3.88 4.65 3.42 3.22 3.01 Outdoor unit Cooling Capacity Total input EER Energy label class A A B Btu/h 0.75 38,200 0.77 47,800 0.75 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.26 4.11 4.60 3.44 3.41 3.48 B B B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 32 40 Air flow CMM 20-21-23-25 27-30-32-34 (Low-Medium2-Medium1-High) External pressure CFM 705-840-810-885 955-1060-1130-1200 Pa dB(A) 0 40-41-43-45 W : mm 1310 Sound level (Low-Medium2-Medium1-High) External finish Dimension 0 41-43-45-46 White Munsell 0.70Y 8.59/0.97 1620 D : mm 680 H : mm W : inch 270 51-9/16 63-3/4 D : inch 26-3/4 H : inch Weight Unit drain pipe I.D. Outdoor unit 10-5/8 kg 37 43 45 lbs 82 95 99 mm 26 inch 1 Air flow CMM Sound level at cooling CFM dB(A) dB(A) 100 3,530 Sound level at heating 49 50 51 External finish Dimension 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 53-1/8 kg 121 116 lbs 267 256 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 42-44-46-48 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46: D.B. 19˚C, W.B. 15˚C D.B. -5: w D.B. 21:, W.B. 15: D.B. 28˚C D.B. -20:, W.B. -20: D.B. 17˚C 17 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 18 Indoor unit PCA-RP100GA PCA-RP125GA PCA-RP140GA Btu/h PUHZ-RP100YHA2 34,100 PUHZ-RP125YHA2 42,700 PUHZ-RP140YHA2 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(5.5-15.3) kW 2.92 3.88 4.65 3.42 3.22 3.01 Outdoor unit Cooling Capacity Total input EER Energy label class A A B Btu/h 0.75 38,200 0.77 47,800 0.75 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.26 4.11 4.60 3.44 3.41 3.48 B B B - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A 16 Air flow CMM 20-21-23-25 27-30-32-34 (Low-Medium2-Medium1-High) CFM 705-840-810-885 955-1060-1130-1200 External pressure Pa dB(A) 40-41-43-45 W : mm 1310 Sound level (Low-Medium2-Medium1-High) 0 0 External finish Dimension 41-43-45-46 White Munsell 0.70Y 8.59/0.97 1620 D : mm 680 H : mm 270 W : inch 51-9/16 63-3/4 D : inch 26-3/4 H : inch Weight Unit drain pipe I.D. Outdoor unit 10-5/8 kg 37 43 45 lbs 82 95 99 mm 26 inch 1 Air flow CMM Sound level at cooling CFM dB(A) dB(A) 100 3,530 Sound level at heating 49 50 51 External finish Dimension 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 53-1/8 kg 135 130 lbs 298 287 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 42-44-46-48 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -20˚C, W.B. -20˚C D.B. 17˚C 18 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 19 Indoor unit PCA-RP71HA PCA-RP125HA PCA-RP125HA Btu/h PUHZ-RP71VHA2 24,200 PUHZ-RP125VHA2 42,700 PUHZ-RP125YHA2 42,700 kW 7.1(3.3-8.1) 12.5(5.5-14.0) 12.5(5.5-14.0) kW 2.21 3.88 3.88 3.21 3.22 3.22 A A A Btu/h 0.74 27,300 0.77 47,800 0.77 47,800 kW 7.6(3.5-10.2) 13.8(5.0-16.0) 13.8(5.0-16.0) kW 2.23 4.05 4.05 3.41 3.41 3.41 B B B - - Outdoor unit Cooling Capacity Total input EER Energy label class SHF Heating Capacity Total input COP Energy label class Booster heater Power supply [ Cycle Hz 50 50 V 230 400 Breaker size 1 A 3 25 16 Air flow (Low-High) CMM 17-19 30-38 CFM 600-670 1060-1350 External pressure Pa dB(A) 0 0 34-38 44-50 W : mm 1136 Sound level (Low-High) External finish Dimension Stainless steel 1520 D : mm 650 H : mm 280 W : inch 44-3/4 D : inch 59-7/8 25-5/8 H : inch Weight Unit drain pipe I.D. 11 kg 41 56 lbs 90 124 mm 26 inch Outdoor unit 1 Air flow CMM 55 1,940 Sound level at cooling CFM dB(A) 100 3,530 47 50 Sound level at heating dB(A) 48 52 W : mm 950 950 D : mm 330+30 330+30 External finish Dimension Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Ivory Munsell 3Y 7.8/1.1 H : mm 943 1350 W : inch 37-3/8 37-3/8 D : inch 13 + 1-3/16 13 + 1-3/16 H : inch 37-1/8 kg 75 116 lbs 165 256 mm 15.88 53-1/8 130 287 15.88 inch 5/8 5/8 mm 9.52 9.52 inch 3/8 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling - Phase Voltage Indoor unit kW Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C D.B. 28˚C D.B. 17˚C Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Outdoor D.B. 46˚C D.B. -5˚C w1 D.B. 21˚C, W.B. 15˚C D.B. -11˚C, W.B. -12˚C w2 19 3. Guaranteed voltage 198~264V, 50Hz (RP125Y : 342~457V, 50Hz) 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit V: Single phase 230V 50Hz, Y: 3 phase 400V 50Hz w1. If optional Air protect guide installed. D.B.-15: w2. For RP125 D.B. -20:, W.B. -20: OCS05A-1.qxp 06.5.15 0:50 PM Page 20 2-5. FLOOR STANDING TYPE Model name Indoor unit PSA-RP71GA Outdoor unit Cooling Capacity Total input Btu/h PUHZ-RP71VHA2 24,200 kW 7.1(3.3-8.1) kW EER Energy label class A SHF Heating Capacity Total input Btu/h 0.73 27,300 kW 7.6(3.5-10.2) kW COP Power supply B kW - Phase [ 1 Cycle Hz 50 V 230 Voltage Breaker size Indoor unit A 25 Air flow (Low-High) CMM 15-18 CFM 530-635 External pressure Pa dB(A) 40-45 Sound level (Low-High) External finish Dimension Weight Unit drain pipeO.D. Outdoor unit White Munsell 0.70Y 8.59/0.97 600 D : mm 270 H : mm 1900 W : inch 23-5/8 D : inch 10-5/8 H : inch 74-13/16 kg 43 lbs 98 mm 20 inch 13/16 Air flow CMM 55 1,940 Sound level at cooling CFM dB(A) Sound level at heating dB(A) Dimension Weight Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Upper limit Lower limit Upper limit Heating Lower limit 47 48 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 943 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch 37-1/8 kg 75 lbs 165 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 0 W : mm External finish Refrigerant pipe size 2.23 3.41 Energy label class Booster heater 2.20 3.23 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -11˚C, W.B. -12˚C D.B. 17˚C 20 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 21 Indoor unit PSA-RP100GA PSA-RP125GA PSA-RP140GA Btu/h PUHZ-RP100VHA2 34,100 PUHZ-RP125VHA2 42,700 PUHZ-RP140VHA2 47,800 kW 10.0(4.9-11.4) 12.4(5.5-14.0) 13.8(5.5-15.3) kW 2.99 4.12 4.91 3.34 3.01 2.81 Outdoor unit Cooling Capacity Total input EER Energy label class A B C Btu/h 0.81 38,200 0.75 47,800 0.74 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.28 4.11 4.97 3.41 3.41 3.22 B B C - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 32 CMM 24-31 26-33 27-35 CFM 850-1060 920-1165 955-1240 External pressure Pa dB(A) Sound level (Low-High) 0 44-49 External finish Dimension 46-51 600 D : mm 350 H : mm 1900 W : inch 23-5/8 D : inch 13-3/4 H : inch 74-13/16 Unit drain pipeO.D. kg 51 53 lbs 112 117 mm 20 inch 13/16 Air flow CMM 100 3,530 Sound level at cooling CFM dB(A) 49 Sound level at heating dB(A) 51 External finish Dimension 50 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 53-1/8 kg 121 116 lbs 267 256 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 47-52 White Munsell 0.70Y 8.59/0.97 W : mm Weight Outdoor unit 40 Air flow (Low-High) Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46: D.B. 19˚C, W.B. 15˚C D.B. -5: w D.B. 21:, W.B. 15: D.B. 28˚C D.B. -20:, W.B. -20: D.B. 17˚C 21 3. Guaranteed voltage 198~264V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM Model name Page 22 Indoor unit PSA-RP100GA PSA-RP125GA PSA-RP140GA Btu/h PUHZ-RP100YHA2 34,100 PUHZ-RP125YHA2 42,700 PUHZ-RP140YHA2 47,800 kW 10.0(4.9-11.4) 12.4(5.5-14.0) 13.8(5.5-15.3) kW 2.99 4.12 4.91 3.34 3.01 2.81 Outdoor unit Cooling Capacity Total input EER Energy label class A B C Btu/h 0.81 38,200 0.75 47,800 0.74 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.0-18.0) kW 3.28 4.11 4.97 3.41 3.41 3.22 B B C - - - SHF Heating Capacity Total input COP Energy label class Booster heater Power supply kW Phase [ Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A 16 Air flow (Low-High) CMM 24-31 26-33 27-35 CFM 850-1060 920-1165 955-1240 External pressure Pa dB(A) 44-49 46-51 Sound level (Low-High) 0 External finish Dimension White Munsell 0.70Y 8.59/0.97 W : mm 600 D : mm 350 H : mm 1900 W : inch 23-5/8 D : inch 13-3/4 H : inch 74-13/16 Weight Unit drain pipeO.D. Outdoor unit kg 51 51 53 lbs 112 112 117 mm 20 inch 13/16 Air flow CMM 100 3,530 Sound level at cooling CFM dB(A) 49 Sound level at heating dB(A) 51 External finish Dimension 50 52 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm 330+30 H : mm 1350 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: 53-1/8 kg 135 130 lbs 298 287 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F) Heating Indoor : D.B. 20: (68˚F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 47-52 Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F) Outdoor : D.B. 7: (45˚F) W.B. 6: (43˚F) Indoor Outdoor D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C D.B. 19˚C, W.B. 15˚C D.B. -5˚C w D.B. 21˚C, W.B. 15˚C D.B. 28˚C D.B. -20˚C, W.B. -20˚C D.B. 17˚C 22 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data based on indicated voltage Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz w If optional Air protect guide installed. D.B.-15: OCS05A-1.qxp 06.5.15 0:50 PM 3 Page 23 OUTLINES AND DIMENSIONS Unit : mm INDOOR UNIT PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA PLA-RP100AA2 PLA-RP125AA2 PLA-RP140AA2 Ceiling hole 860 - 910 20 - 45 20 - 45 159 20 - 45 810 Suspension bolt pitch Fresh air intake 16 197 {125 Burring hole pitch 120 _ 158 20 - 45 3 - {2.8 Burring hole 120_ 159 C 89 Detail drawing of fresh air intake 98 192 {150 159 840 {100 (Cut out hole) Suspension bolt M10 or W3/8 1 Ceiling surface Feeding hole (Drain pump) 286 374 60 860 - 910 Ceiling hole Terminal block 840 14 - {2.8 Burring hole Suspension bolt pitch 605 Branch duct hole 350 {175 167 155 159 130 70_ 100 90 100 100 90 Branch duct hole (Cut out hole) Drain pipe VP-25connection (O.D.{32) High efficiency filter & Fresh air intake casement (option) 17 +50 B 30 190 135 Ceiling surface 17 Control wire entry Power line entry Suspension bolt lower edge +5 0 105 50 - 70 170 140 A 2 577 Air intake hole Air intake grille Grille Drain hole M A M Emergency operation switch (cooling) 950 Emergency operation switch (heating) Auto vane 577 Air intake hole (WIRELESS PANEL) 411 Air outlet hole A DEFROST/STAND BY lamp M Receiver 77 Operation lamp M 51 411 Air outlet hole 950 Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size 1 LIQUID SIDE 2 GAS SIDE RP35, 50 RP60 RP71 RP100, 125, 140 [6.35 [6.35 — — [9.52 [9.52 [9.52 [9.52 [12.7 — — — [15.88 [15.88 [15.88 [15.88 — — — [19.05 Models A B C PLA-RP60,71AA 241 258 80 PLA-RP100,125,140AA2 281 298 84 PLA-RP35,50AA Factory flare nut attachment to the heat-exchanger. 23 Vane motor 77 51 Branch duct hole OCS05A-1.qxp 06.5.15 0:50 PM Page 24 Unit : mm PEAD-RP35EA2 PEAD-RP50EA PEAD-RP60EA Model A RP35,50 772 RP60 B 305 1012 280 w Setting at shipment F G R410A Outdoor unit : 6.35 w R410A Outdoor unit : 12.7 w R407C Outdoor unit : 9.52 R407C Outdoor unit : 15.88 Outdoor unit (SUZ) : 6.35 15.88 290 1070 1044 R407C Outdoor unit : 9.52 w C D E - 830 804 Service space:500 or more 50~150 29 Refrigerant piping flare connection (liquid [ F copper tube):HP Refrigerant piping flare connection (gas [G copper tube):LP Drain R1(External thread) Electrical parts box Drain Pump (Option) Set Drain Pipe (Option) ... Flexible joint VP-25(I.D. [32) Filter 55 Access door 81 C B 81 197 450 Lifting bolt hole (14×22) C 13 13 30 277 45 80 85 282 288 256 176 Air inlet E 6 40 24 10 179 227 2 35 1 243 109 3.5 21 10 10- [3 (RP35,50) 12- [3 (RP60) D 30 61 4 In case of rear inlet 81 A 44 75 640 30 B 10 18 56 355 365~465 159 1 2 3 4 5 6 7 10- [3 (RP35,50) 12- [3 (RP60) A 10 450 5 7 3.5 Air outlet 3 Keep duct-work length 850mm or more. Be sure to apply the air filter near the air inlet grille. In case of bottom inlet 10- [3 (RP35,50) 12- [3 (RP60) Air outlet 10 7 40 15 176 256 10 3.5 81 C B 81 A Air inlet PEAD-RP71EA PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA Service space:500 or more Air inlet 375 Lifting bolt hole (14x22) 12-[3 44 E 75 D 243 6 5 7 Air outlet 4 C A 13 307 45 122 113 1 81 80 2 35 53 B 365~465 323 308 30 10 680 C 197 450 169 20 30 12-[3 A 81 81 210 7 140 6 282 5 3.5 30 4 40 3 Refrigerant piping flare connection (liquid [9.52 copper tube):HP Refrigerant piping flare connection (gas [F copper tube):LP Drain R1 (External thread) Electrical parts box Drain Pump (Option) Set Drain Pipe (Option) ... Flexible joint VP25(I.D.[32) Filter 319 261 181 2 3.5 1 55 Access door 3 Keep duct-work length 850mm or more. Be sure to apply the air filter near the air inlet grille. 24 B 81 10 F A B C D E Model 15.88 RP71 1012 280 290 1070 1044 RP100,125 1252 360 370 1310 1284 R410A Outdoor unit : 15.88 w RP140 1552 460 470 1610 1584 R407C outdoor unit : 19.05 w Setting at shipment 10 50~150 29 450 13 30 OCS05A-1.qxp 06.5.15 0:50 PM Page 25 Unit : mm PEAD-RP60GA PEAD-RP71GA PEAD-RP100GA Model A B C D E RP60 1125 1090 1050 1012 7 RP71 1125 1090 1050 1012 7 F G H Outdoor unit(SUZ) : 6.35 Other outdoor unit : 9.52 w 840 8 9.52 840 8 RP100 1365 1330 1290 1252 9 1080 10 9.52 w Setting at shipment 25 J 15.88 15.88 R410A Outdoor unit : 15.88 w R407C Outdoor unit : 19.05 360 405 420 495 Sleeve w1 [90 MITSUBISHI ELECTRIC 150 or more m r.SLI m Through hole [90~[100 205 245 70 21 R52.5 Liquid pipe Gas pipe 990 705 Air outlet 80 715 Air intake 400 12-Louvers(manual) 340 Air intake ëOñ Å@ÇeÇqÇnÇmÇs 449 581 ÅrÇoÇoÅqÅ@ 700 (Flexible hose total length800) ÅrÇoÇoÅqÅ@ 395 Auto vane 280 Air intake 225 40 86 54 70 35 MITSUBISHI ELECTRIC mr.SLIm 190 160 235 ON STAND COOL HEAT OFF BY 233 153 (Right side piping installation) Terminal block for power supply (Heater (PKH-P35, 50GALH only)) Terminal block to outdoor unit Service panel (Power supply access) — [9.52 — [6.35 [9.52 [12.7 P35, 50 RP35, 50 INDOOR UNIT PKA-RP35GAL PKA-RP50GAL [15.88 [15.88 : Factory flare nut attachment to the heat - exchanger. GAS SIDE LIQUID SIDE Knock out hole for right piping Refrigerant pipe.Drain pipe. Wiring hole Less than 15 Knock out hole for under piping Refrigerant piping.Drain pipe. Wiring hole 235 60 Right side Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size ëOñ Å@ÇeÇqÇnÇmÇs Front view(to open the grille) Filter grip 50 Lower side (Left side piping installation) Unit drain pipe O.D.20 35 272 310 322 230 190 130 0 35 55 80 (Necessary clearance for Unit installation) Less than 130 Right side 60 340 w1 Sleeves are available on the market. w2 This size shows the lower end of through hole. Right-rear piping hole R52.5 Unit center Installation plate balance point hole Knock out hole for right-rear piping 5 Model 35, 50 2. Knock out hole for left-rear piping 300 R5 Left-rear piping hole 49-[5hole for tapping screw 245 HEAT 95 Details of installation plate 190 230 210 14-[14hole for bolts 5 STAND COOL BY 150 50 or more 135 2. R5 ON OFF 75 32 20 0 35 0 26 170 190 30 or more 180 or more 260 Allowing clearances Front view 320 345 53 79 Knock out hole for left piping Refrigerant pipe.Drain pipe.Wiring hole. 495 Front view 80 Left side 425 198 Air intake 60 280 06.5.15 0:50 PM 31 245 70 21 OCS05A-1.qxp Page 26 Unit : mm OCS05A-1.qxp 06.5.15 0:50 PM Page 27 Unit : mm PKA-RP60FAL PKA-RP71FAL Display section 62.5 Top 45 235 235 45 235 45 Defrosting Initial heating lamp 13 235 Power lamp Front Right side 1400 Left side Emergency switch(Heat) Emergency switch(Cool) Receiving section 235 Knock out hole for right piping Refrigerant pipe. Drain pipe 340 A 197 1090 Air intake Terminal block for indoor/outdoor connecting line 15 Terminal block for heater (PKH only) Liquid pipe Knock out hole for left piping C Gas pipe 25 Drain hose for left-hand side piping 58 42 Bolt Drain hose O.D.20 Drain hose 1110 183 55 (Gas pipe) 107 120 111 (Liquid pipe) Lower side Liquid pipe [9.52(3/8F) Gas pipe [15.88(5/8F) Auto vanes 1120 240 552 Air outlet 552 Air outlet Louvers (manual) Under panel Removable at left-hand side piping Knock out hole for under-piping B Refrigerant pipe. Drain pipe Unit center 990 245 455 Knock out hole for wiring 91 225 240 180 12-ø6 hole for tapping screw 280 314 610 90 Rear piping opening Range for left rear piping opening 27 C 30 100 B 37 74 39 98 32 39 37 74 4 32-ø12 hole for bolt 30 60 184 30 66-ø6 hole for tapping screw A 30 37 65 on left-hand side Drainage range on right-hand side 100 4 39 18 285 19 10 30 80 29 280 Wall fixture 10 91=(910) 900 18 Drainage range OCS05A-1.qxp 06.5.15 0:50 PM Page 28 Unit : mm PKA-RP100FAL Top 62.5 Display section 45 235 45 235 45 235 235 45 13 235 Receiving section Emergency switch(Heat) Emergency switch(Cool) Defrosting Initial heating lamp Power lamp Front Left side Knock out hole for right piping Right side 1680 235 1370 Air intake 340 197 A Knock out hole for left piping C Terminal block for indoor/outdoor connecting line 15 Terminal block for heater (PKH only) Liquid pipe Gas pipe 25 Drain hose O.D.20 Drain hose Drain hose for left-hand side piping 58 42 Bolt 1110 Drain hose 183 Lower side 1400 55 (Gas pipe) 102 120 111 (Liquid pipe) 240 694 Air outlet Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size RP100 P100 694 Air outlet LIQUID SIDE [9.52 [9.52 [15.88 [19.05 [19.05 : Factory flare nut attachment to the heat-exchanger. GAS SIDE Louvers (manual) B Under panel (Removable at left-hand side piping) Auto vane Knock out hole for under-piping Refrigerant pipe. Drain pipe Unit center 1270 Knock out hole for wiring Drainage range 91 on right-hand side 60 295 225 Range for left rear piping opening 240 180 280 750 30 41-ø12 hole for bolt 314 90 Rear piping opening Range for left rear piping opening 12-ø6 hole for tapping screw 28 A 30 B C 30 100 Drainage range on left-hand side 285 19 37 74 39 98 32 39 13 91=(1183) 900 37 74 4 18 37 65 18 184 30 84-ø6 hole for tapping screw 245 595 10 30 80 29 280 Wall fixture 100 4 39 Unit out line OCS05A-1.qxp 06.5.15 0:50 PM Page 29 Unit : mm INDOOR UNIT PCA-RP50GA NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 140 70 320 150 80 17 6 933 (suspension bolt pitch) 85 983 15 81 76 7 226 2 157 Electrical box 180 210 70 904 182 1000 gas 241 (Drainage) 254 506 680 56 Air outlet liquid 201 Air intake 161 90 918 5 1 4 38 131 161 46 175 1 8 38 79 Ceiling 6~7 42 32 Electrical box [Front view] 179 3 2 1 2 3 4 5 6 7 8 Use the current nuts meeting the pipe size of the outdoor unit. 86 138 171 263 352 525 Drainage pipe connection (26mm I.D.) Drainage pipe connection (for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection (gas pipe side/flared connection) Refrigerant-pipe connection (liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for left drain pipe arrangement Knock out hole for wiring arrangement Available pipe size RP50 P50 5 LIQUID SIDE [6.35 928 [9.52 4 GAS SIDE When electrical box is pulled down [9.52 [12.7 [15.88 [15.88 : Factory flare nut attachment to the heat-exchanger. 29 OCS05A-1.qxp 06.5.15 0:50 PM Page 30 Unit : mm PCA-RP60GA PCA-RP71GA NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 140 70 320 150 80 17 6 1240 (suspension bolt pitch) 85 1290 Electrical box 15 2 226 210 180 81 76 7 157 70 1214 182 (liquid) 1310 201 (5/8F gas) 241 (Drainage) 254 506 680 56 Air outlet Air intake 161 90 1228 38 131 161 525 1 4 46 175 1 Ceiling 5 8 3879 32 [ Front view ] 6~7 42 179 3 Electrical box 2 1 2 3 4 5 6 7 8 Drainage pipe connection (26mm I.D.) Drainage pipe connection (for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection (gas pipe side/flared connection) Refrigerant-pipe connection (liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for left drain pipe arrangement Knock out hole for wiring arrangement Use the current nuts meeting the pipe size of the outdoor unit. 86 138 171 263 416 1235 Available pipe size RP60 RP71,P60,P71 5 LIQUID SIDE [6.35 [9.52 [9.52 4 GAS SIDE When electrical box is pulled down [15.88 [15.88 : Factory flare nut attachment to the heat-exchanger. 30 OCS05A-2.qxp 06.5.15 0:52 PM Page 31 Unit : mm PCA-RP100GA NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 140 70 320 150 80 18 6 1240 (suspension bolt pitch) 87 70 16 2 229 217 270 81 96 7 207 Electrical box 1214 182 (3/8F liquid) 1310 198 (5/8F, 3/4F gas) 245 (Drainage) 254 506 680 56 Air outlet Air intake 161 90 1228 Ceiling 8 5 1 4 6~7 38 192 45 42 236 38 140 1 93 [ Front view ] 160 239 3 Electrical box 2 525 86 138 171 263 1 2 3 4 5 6 7 8 Drainage pipe connection (26mm I.D.) Drainage pipe connection (for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection (gas pipe side/flared connection) Refrigerant-pipe connection (liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for left drain pipe arrangement Knock out hole for wiring arrangement Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size RP100 P100 5 LIQUID SIDE 687 1235 [9.52 [9.52 [15.88 [19.05 [19.05 4 GAS SIDE When electrical box is pulled down :Factory flare nut attachment to the heat-exchanger. 31 OCS05A-2.qxp 06.5.15 0:52 PM Page 32 Unit : mm PCA-RP125GA PCA-RP140GA NOTES: 1. Use M10 or W3/8 screws for anchor bolt. 2. When optional drain lift-up mechanism is installed, always provide upward piping for refrigerant piping. 140 70 320 150 80 18 6 1547(suspension bolt pitch) 87 70 16 229 2 217 270 81 96 7 207 Electrical box 1524 182 (3/8F liquid) 1620 198 (5/8F, 3/4F gas) 245 (Drainage) 254 506 680 56 Air outlet Air intake 161 90 1535 [ Front view ] Ceiling 8 5 1 4 192 236 Drainage pipe connection (26mm I.D.) Drainage pipe connection (for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection (gas pipe side/flared connection) Refrigerant-pipe connection (liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for left drain pipe arrangement Knock out hole for wiring arrangement 6~7 38 45 42 160 38 140 1 93 Electrical box 239 3 2 1 2 3 4 5 6 7 8 525 687 1545 When electrical box is pulled down 86 138 171 263 Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size RP125,140 P125,140 5 LIQUID SIDE [9.52 [9.52 4 GAS SIDE [15.88 [19.05 [19.05 :Factory flare nut attachment to the heat-exchanger. 32 <Air intake> 1098 1136 986 <Air outlet> bolt pitch> 75 21 110 <gas> <liquid> 175 Suspension bolt 75 80 70 Filter element for the exchange model:PAC-SG38KF-E (12pcs.) 360 handle 3 or more 100 <Flexible hose(accessory)> 650 289 <Suspension bolt pitch> 320 495 <Filter contour dimension> Filter (3-pieces) Inspection port (pipe sensor) <Air outlet> 1 243 1 Rear wall Adjustable part 85 45 1136 Ceiling 176 105 140 18 318 2 4 or more 100 366 6 8 7 0 90˚ Terminal block box [2 22 [ 20 9 130 250 Less than Allowing clearances 480 (122 ) Refrigerant-pipe connection(gas pipe side/flared connection : 5/8F) Refrigerant-pipe connection(liquid pipe side/flared connection : 3/8F) Flexible hose(accessory) Drainage pipe connection(26mm I.D.) Knock out hole for behind refrigerant-piping arrangement Knock out hole for upper refrigerant-pipe arrangement Knock out hole for wiring arrangement : 2- [ 27 Terminal block(indoor/outdoor connecting line) Terminal block(remote controller) Knock out hole (duct for fresh air intake): 2- [ 200 Option parts:duct flange( [ 200). model: PAC-SF28OF-E(1 pc.) 43 1 2 3 4 5 6 7 8 9 75 1224 1180 <Suspension NOTES. 1.Use M10 or W3/8 screw for anchor bolt. The half bottom of FAN CASING can be separated. Electrical box 102 110 258 254 295 197 <Air intake> 70~90 13 2 15 650 280 16 288 120 165 90 Less than 210 38 130 300 5 Less than Terminal block box 500 33 or more PCA-RP71HA 2~3 06.5.15 0:52 PM (Gap to ceiling) OCS05A-2.qxp Page 33 Unit : mm Use the current nuts meeting the pipe size of the outdoor unit. NOTES. 1.Use M10 or W3/8 screw for anchor bolt. The half bottom of FAN CASING can be separated. <Air intake> 1482 1520 outlet> 75 21 1 GAS SIDE 2 LIQUID SIDE Available pipe size <Suspension bolt pitch> 1370 <Air 1564 Suspension bolt 80 650 289 70 <Suspension bolt pitch> 320 495 [ 19.05 [ 15.88 [ 9.52 RP125 or more 85 140 2 4 Rear wall 298 176 105 Adjustable part 3 1 18 45 1520 Ceiling 246 6 440 (122) 7 440 or more 100 9 [2 22 0 [20 250 Less than Allowing clearances Terminal block box 8 : Factory flare nut attachment to the heat-exchanger Filter element for the exchange model:PAC-SG38KF-E (12pcs.) 360 handle 100 <Flexible hose(accessory)> 75 <Filter contour dimension> Filter (4-pieces) Inspection port (pipe sensor) 75 1608 197 <liquid> 1 243 Electrical box 43 110 102 110 258 254 295 175 <Air outlet> <Air intake> 70~90 13 120 90 <gas> 280 16 288 210 38 2 650 165 Refrigerant-pipe connection(gas pipe side/flared connection : 5/8F, 3/4F) Refrigerant-pipe connection(liquid pipe side/flared connection : 3/8F) Flexible hose(accessory) Drainage pipe connection(26mm I.D.) Knock out hole for behind refrigerant-piping arrangement Knock out hole for upper refrigerant-pipe arrangement Knock out hole for wiring arrangement : 2- [ 27 Terminal block(indoor/outdoor connecting line) Terminal block(remote controller) Knock out hole (duct for fresh air intake) : 2- [ 200 Option parts:duct flange( [ 200). model: PAC-SF28OF-E(1 pc.) 300 1 2 3 4 5 6 7 8 9 Less than 130 Terminal block box 15 Less than 130 90˚ 5 500 34 or more PCA-RP125HA 2~3 06.5.15 0:52 PM (Gap to ceiling) OCS05A-2.qxp Page 34 Unit : mm 10 10 38 controller Front side Knock out hole for refrigerant and drainage. 90 60 oval (Provided on both sides) 235 70 600 71 250 270 180 130 Metal fixture against overturning 530 520 260 240 370 340 125 132 15 111 Knock out hole for branch duct 100 130 130 38 20 10 827 30 130 50 260 Knock out hole for under-piping(120 70 oval) Terminal block for heater power supply 22 (Only PSH-P•GAH) Terminal block for indoor/outdoor connection. Knock out hole for bottom fixing 95 50 Knock out hole for wiring.[27 (Provided on both sides) Front side Rear side A 105 Knock out hole for under-piping Drain pipe Gas pipe [15.88(5/8F) Liquid pipe [ 9.52(3/8F) Knock out hole for piping and wiring (140 80 oval) 47 95 Electrical parts box 277 461 20 20 160 218 VIEW "A" 100 240 115 40 1900 175 123 714 766 608 216 90 767 143 55 Rear side 110 35 590 40 186 66 100 or more Front 1,000 or more 1. Service access allows for insertion of screw driver. 2. Adjustable 100 or more 06.5.15 0:52 PM 480 INDOOR UNIT PSA-RP71GA 1 2 300 or more 5 or more OCS05A-2.qxp Page 35 Unit : mm controller Knock out hole for refrigerant and drainage. 90 60 oval (Provided on both sides) 315 70 600 71 330 350 260 130 Metal fixture against overturning 530 520 260 240 370 340 125 130 130 10 10 38 38 Front side 100 15 111 Knock out hole for branch duct 130 50 260 20 132 40 1900 240 Knock out hole for 95 under-piping(120 70 oval) Knock out hole for wiring.[27 (Provided on both sides) A 20 461 Front side Rear side 105 [15.88(5/8F) [19.05(3/4F) Gas pipe Drain pipe [9.52(3/8F) Liquid pipe Knock out hole for piping and wiring (140 80 oval) 47 95 [ 9.52 — [ 19.05 [ 9.52 [ 15.88 [ 19.05 40 261 66 100 or more Front 1,000 or more 1. Service access allows for insertion of screw driver. 2. Adjustable 100 or more RP100,125,140 P100,125,140 : Factry flare nut attachment to the heat-exchanger GAS SIDE LIQUID SIDE Available pipe size Use the current nuts meeting the pipe size of the outdoor unit. Knock out hole for under-piping Electrical parts box 277 120 20 218 VIEW "A" Knock out hole for bottom fixing Terminal block for indoor/outdoor connection. Terminal block for heater power supply (Only PSH-P•GAH) 22 50 120 Rear side 115 10 827 30 255 123 714 766 608 216 140 767 201 77 110 36 590 06.5.15 0:52 PM 480 PSA-RP100GA PSA-RP125GA PSA-RP140GA 1 2 300 or more 5 or more OCS05A-2.qxp Page 36 Unit : mm 06.5.15 0:52 PM Page 37 Unit : mm OUTDOOR UNIT PUHZ-RP35VHA2 PUHZ-RP50VHA2 400 [33 drain hole 347.5 365 300 Air intake [33 drain hole 330 155 152 43.6 Air intake 45.4 40 18 23 32.5 4-10 o 21 oval hole (M10 foundation bolt) Service panel Service panel for charge plug Air discharge Handle for moving 150 Connection for gas pipe 90 10 155 300 43 35 600 Connection for liquid pipe 183 69 287.5 Service port Installation bolt pitch: 500 800 1. FOUNDATION BOLTS 2. PIPING-WIRING DIRECTION Please secure the unit firmly Piping and wiring connection can with 4 foundation (M10) bolts. be made from the rear direction only. (Bolts, washer and nut must be purchased locally.) Free space around the outdoor unit (basic example) 3. ATTACHING THE CONDUIT 100 mm In order to attach the conduit, it is necessary to fix the metal plate with 2 screws to the back panel. Procure the metal plate and make screw holes locally. It is recommended to use the metal plate shown below. Align the metal plate to the marks on the unit and attach it. <Foundation bolt height> w1 re r mo mo m 100 18 or below 100 mm or more as long as no obstacle is placed on the rear and light-and-left sides of the unit. Basically open FOUNDATION or m ore w1 w2 w The position and the size of conduit hole depend on the conduit to be used. re 500 mm o or m 350 mm 40 20 or m ore 2 sides should be open in the right, left and rear side. Minimum installation space for outdoor unit 80 w Conduit hole 60 OCS05A-2.qxp w 1 In the place where short cycle tends to occur, cooling and heating capacity and power consumption might get lowered 10%. Air outlet guide (optional PAC-SG58SG) will help them improve. w 2 If air discharges to the wall, the surface might get stained. Holes for metal plate fixing screw w The size of hole depends on the screw to be used. 37 OCS05A-2.qxp 06.5.15 0:52 PM Page 38 Unit : mm Ov Ov er 10 mm er 50 0m m F R E E Ov er 10 Ov er mm 10 0m m PUHZ-RP60VHA2 PUHZ-RP71VHA2 38 mm m FREE m 0m Ov er 1 10 Service space Over Front piping hole (Knock-Out) 92 [92 Front trunking hole 40 (Knock-Out) 65 45 Power supply wiring hole (2-[27Knock-Out) 19 92 75 Right piping hole (Knock-Out) 55 [92 Air intake Less than 500 40 Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally.) 65 92 [92 40 Handle for moving Handle for moving Rear piping hole (Knock-Out) Rear trunking hole (Knock-Out) Side Air Intake Rear Air Intake Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. 4 PIPING-WIRING DIRECTIONS Power supply wiring hole (2-[27Knock-Out) FOUNDATION <Foundation bolt height> 45 Right trunking hole (Knock-Out) Power supply wiring hole (2-[27Knock-Out) 500 Over Handle for moving Piping Knock-Out Hole Details 55 27 150 Dimensions of space needed for service access are shown in the below diagram. 1 • • • Refrigerant GAS pipe connction (FLARE)[15.88 (5/8F) 2 • • • Refrigerant LIQUID pipe connection (FLARE)[ 9.52 (3/8F) w1 • • • Indication of STOP VALVE connection location. m 0m 5 er 1 Ov Example of Notes er1 Ov 000 0m er 1 Ov 63 73 30 The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. 23 27 92 Over Over 3 FOUNDATION BOLTS 175 322 145 Air Discharge Installation Feet 600 Rear Air Intake 66 175 2-U Shaped notched holes (Foundation Bolt M10) Handle for moving 30 220 145 145 Earth terminal 950 42 Side Air Intake 1350 2 SERVICE SPACE Drain hole (5-[33) 71 2 1 Handle for moving Service panel Terminal connection Left • • • Power supply wiring Right • • Indoor/Outdoor wiring 2-12o36 Oval holes (Foundation Bolt M10) 71 635 371 417 1 FREE SPACE (Around the unit) 73 63 23 73 63 23 55 27 330 30 23 219 19 45 56 370 53 28 Front piping cover RP·YHA2 RP·VHA2 A 930 1,076 Rear piping cover Bottom piping hole (Knock-Out) w1 443 39 81 PUHZ-RP100VHA2 PUHZ-RP125VHA2 PUHZ-RP140VHA2 PUHZ-RP100YHA2 PUHZ-RP125YHA2 PUHZ-RP140YHA2 A 06.5.15 0:52 PM w1 447 OCS05A-2.qxp Page 39 Unit : mm OCS05A-2.qxp 06.5.15 0:52 PM Page 40 Unit : mm WIRED REMOTE CONTROLLER 120 130 19 40 06.5.15 0:52 PM Page 41 Unit : mm WIRELESS REMOTE CONTROLLER 58 159.3 55 19 OCS05A-2.qxp 41 OCS05A-2.qxp 06.5.15 0:52 PM Page 42 WIRING DIAGRAM 4 PLA-RP35AA [LEGEND] SYMBOL P.B I.B FUSE ZNR BCR CN2L CN32 CN41 CN51 LED1 LED2 LED3 X1 X4 SW1 SW2 SWE C PLA-RP50AA NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE(T6.3AL250V) VARISTOR FAN CONTROL ELEMENT CONNECTOR(LOSSNAY) CONNECTOR(REMOTE SWITCH) CONNECTOR(HA TERMINAL-A) CONNECTOR(CENTRALLY CONTROL) POWER SUPPLY(I.B) POWER SUPPLY(I.B) TRANSMISSION(INDOOR-OUTDOOR) RELAY(DRAIN PUMP) RELAY(FAN MOTOR) SWITCH(MODEL SELECTION) See table 1 SWITCH(CAPACITY CORD) See table 2 CONNECTOR(EMERGENCY OPERATION) CAPACITOR(FAN MOTOR) PLA-RP60AA SYMBOL MF MV H2 DP DS TB2 PLA-RP71AA NAME SYMBOL FAN MOTOR W.B VANE MOTOR RU DEW PREVENTION HEATER BZ DRAIN-UP MACHINE LED1 DRAIN SENSOR LED2 TERMINAL BLOCK SW1 (INDOOR UNIT POWER(OPTION)) SW2 TERMINAL BLOCK (INDOOR/ OUTDOOR CONNECTING LINE) TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE) ROOM TEMP.THERMISTOR (0˚C/15kΩ,25˚C/5.4kΩ DETECT) PIPE TEMP.THERMISTOR/LIQUID (0˚C/15kΩ,25˚C/5.4kΩ DETECT) COND./EVA. TEMP. THERMISTOR (0˚C/15kΩ,25˚C/5.4kΩ DETECT) WIRED REMOTE CONTROLLER BOARD TB4 TB5, TB6 TH1 TH2 TH5 R.B NAME WIRELESS REMOTE CONTROLLER BOARD RECEIVING UNIT BUZZER LED(RUN INDICATOR) LED(HOT ADJUST) SWITCH(HEATING ON/OFF) SWITCH(COOLING ON/OFF) GRILLE MV MV MV MV 5 5 5 5 H2 5 MF 3 2 1 DC 13.1V 2 1 1 2 3 6 7 4 8 9 5 10 1 2 3 CNSK P.B (RED) CN2S (WHT) TB4 YLW S1 ORN S2 ORN S3 BRN TO OUTDOOR UNIT 5 1 2 3 DP FAN 1 3 5 (WHT) X4 X1 BRN ORN BLK WHT YLW ORN RED WHT D.U.M 1 3 D.HEATER 1 3 1 3 CNC(RED) CNP POWER (BLU) CNDK (RED) X4 1 3 VANE CND POWER INDOOR/OUTDOOR CN6V (ORN) CN2D COMMUNICATION (GRN) (WHT) CN3C (BLU) CN51 CN41 CN2L 1 3 POWER 1 2 FUSE BCR YLW YLW X1 ZNR CN32 SWE SW2 SW1 ON OFF LED3 LED2 HEATER D.SENSOR CN24 CN31 (YLW) (WHT) DS Refer to tables 1 and 2. BLU BLU 1 2 3 LED1 INTAKE LIQUID PIPE REMOCON CN20 CN21 CN29 CN22 WIRELESS (RED) (WHT) (BLK) (BLU) CN90 1 2 1 2 1 2 1 2 (WHT) TH1 2 1 W.B BZ 9 SW1 SW2 RU R.B 1 2 TB6 TB2 RED BLU GRN/YLW 1 (Fig.1) TH3 NOTES: 1.Symbols used in wiring diagram above are, : Connector, : Terminal (block). 2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3). 3.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 4.This dlagram shows the wiring of Indoor and Outdoor connecting wires (specification of 230V), adopting superimposed system of power and signal. I.B 1 3 1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1. 2 ; For power supply system of this unit, refer to the caution label located near this diagram. Table 1 Table 2 SW1 MODELS Service board PLA-RP. AA LED1 TB5 TRANSMISSION WIRES DC12V TH2 LED2 CNB 1 2 3 4 5 ON OFF MODELS SW2 Service board PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 ON OFF ON OFF ON OFF ON OFF 42 L N YLW TB4S1 ORN S2 ORN S3 BRN YLW ORN I.B YLW YLW RED WHT BLK C 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT Please set the voltage using the remote controller. For the setting method. please refer to the indoor unit Installation Manual. OCS05A-2.qxp 06.5.15 0:52 PM Page 43 PLA-RP100AA2 PLA-RP125AA2 PLA-RP140AA2 [LEGEND] SYMBOL P.B FUSE ZNR IPM I.B CN2L CN32 CN41 CN51 LED1 LED2 LED3 X1 SW1 SW2 SWE MF NAME INDOOR POWER BOARD FUSE(T5AL250V) VARISTOR POWER MODULE INDOOR CONTROLLER BOARD CONNECTOR(LOSSNAY) CONNECTOR(REMOTE SWITCH) CONNECTOR(HA TERMINAL-A) CONNECTOR(CENTRALLY CONTROL) POWER SUPPLY(I.B) POWER SUPPLY(I.B) TRANSMISSION(INDOOR-OUTDOOR) RELAY(DRAIN PUMP) SWITCH(MODEL SELECTION)wSee table 1 SWITCH(CAPACITY CORD)wSee table 2 CONNECTOR(EMERGENCY OPERATION) FAN MOTOR SYMBOL MV H2 DP DS TB2 TB4 NAME SYMBOL VANE MOTOR W.B DEW PREVENTION HEATER RU DRAIN-UP MACHINE BZ DRAIN SENSOR LED1 TERMINAL BLOCK (Indoor unit Power (option)) LED2 TERMINAL BLOCK SW1 (INDOOR/OUTDOOR CONNECTING LINE) SW2 TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE) REACTOR ROOM TEMP.THERMISTOR (0:/15k",25:/5.4k" DETECT) PIPE TEMP.THERMISTOR/LIQUID (0:/15k",25:/5.4k" DETECT) COND./EVA. TEMP. THERMISTOR (0:/15k",25:/5.4k" DETECT) WIRED REMOTE CONTROLLER BOARD TB5, TB6 DCL TH1 TH2 TH5 R.B NAME WIRELESS REMOTE CONTROLLER BOARD RECEIVING UNIT BUZZER LED(RUN INDICATOR) LED(HOT ADJUST) SWITCH(HEATING ON/OFF) SWITCH(COOLING ON/OFF) 5 MF BLK WHT RED 3 2 1 5 3 1 IPM CN2S (WHT) 2 1 P.B POSITION DETECTION SENSOR INPUT CN3 (WHT) CN4 (WHT) FUSE TRANS ZNR RECTIFIER 3 FAN 2 CN2 1 (GRN) CN01 (BLK) 5 3 1 CN03 (BLU) DCL YLW TB4 YLW S1 ORN S2 ORN S3 BRN YLW ORN CN02 2 1 (GRN) 1 3 5 FAN 1 2 3 CN33 (GRN) D.U.M 1 3 CNP (BLU) X1 D.HEATER 1 3 CNC (RED) X1 J42 J41 Refer to tables 1 and 2. 1 2 3 DS PLA-RP100AA2 PLA-RP125AA2 LED1 SW1 SW2 1 2 3 4 5 1 2 3 4 5 ON OFF R.B 1 2 TB6 w1 (Fig.1) CN01 (BLK) Please set the voltage using the remote controller. For the setting method. please refer to the indoor unit Installation Manual. P.B 5 3 1 TB2 YLW ORN 1 3 ON OFF 43 INDOOR/OUTDOOR COMMUNICATION CN3C (BLU) Manufacture/Service 1 2 3 4 5 ON OFF RED BLU GRN/YLW L N YLW TB4S1 ORN S2 ORN BRN S3 I.B PLA-RP140AA2 RU TB5 w1 ; When work to supply power separately to indoor and outdoor unit was applied, refer to Fig1. w2 ; For power supply system of this unit, refer to the caution label located near this diagram. ON OFF LED2 CNB : Connector, : NOTES: 1.Symbols used in wiring diagram above are, Terminal (block). 2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3). 3.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 4.This dlagram shows the wiring of indoor and outdoor connecting wires. (specification of 230V), adopting superimposed system of power and signal. 1 2 3 4 5 BZ TRANSMISSION WIRES DC12V (Table 2) SW2 (CAPACITY CORD) SW2 MODELS Manufacture/Service MODELS H2 W.B INTAKE LIQUID PIPE REMOCON CN20 CN21 CN29 CN22 WIRELESS (RED) (WHT) (BLK) (BLU) CN90 1 2 1 2 1 2 1 2 (WHT) 2 1 5 GRILLE 9 TH1 5 1 2 3 6 7 4 8 9 5 10 CN41 CN2L wBe sure to turn off the source power TH2 and then disconnect fan motor connector. (Failure to do so will cause trouble in Fan motor) TH5 (Table 1) SW1 (MODEL SELECTION) SW1 Manufacture/Service 5 5 CND INDOOR/OUTDOOR POWER CN6V (ORN) COMMUNICATION CN2D (GRN) CN3C (WHT) 5 (BLU) CN32 BLU BLU SWE SW2 ON OFF 5 1 2 VANE 1 3 POWER 1 3 CN51 LED3 LED2 LED1 SW1 Pair No. D.SENSOR CN31 (WHT) MV MV MV MV BLK WHT BRN ORN ORN YLW YLW YLW I.B GRILLE YLW YLW PNK WHT BLK DP TO OUTDOOR UNIT POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT OCS05A-2.qxp 06.5.15 0:52 PM Page 44 PEAD-RP35EA2 PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA2 PEAD-RP125EA PEAD-RP140EA SYMBOL I.B. FUSE ZNR CN2L CN24 CN32 CN41 CN51 CN90 LED1 LED2 LED3 SW1 NAME SYMBOL INDOOR CONTROLLER BOARD SW2 FUSE(T6.3AL250V) SWE VARISTOR X1 CONNECTOR(LOSSNAY) X4 X5 CONNECTOR(HEATER) CONNECTOR(REMOTE SWITCH) X6 CONNECTOR(HA TERMINAL-A) P.B. CONNECTOR(CENTRALLY CONTROL) DRAIN PUMP CONNECTOR(WIRELESS) DP POWER SUPPLY(I.B.) DS POWER SUPPLY(REMOTE CONTROLLER) C TRANSMISSION(INDOOR•OUTDOOR) MF SWITCH(MODEL SELECTION) NAME SYMBOL SWITCH(CAPACITY CORD) TB4 SWITCH(EMERGENCY OPERATION) RELAY(DRAIN PUMP) TB5 RELAY(FAN MOTOR) TH1 RELAY(FAN MOTOR) RELAY(FAN MOTOR) TH2 INDOOR POWER BOARD (OPTIONAL PARTS) TH5 DRAIN PUMP DRAIN SENSOR CAPACITOR(FAN MOTOR) FAN MOTOR NAME TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE) TERMINAL BLOCK(REMOTE CONTROLLER) INTAKE AIR TEMP. THERMISTOR (0: /15t,25:/5.4t DETECT) PIPE TEMP. THERMISTOR/LIQUID (0: /15t,25:/5.4t DETECT) COND./EVA. TEMP. THERMISTOR (0: /15t,25:/5.4t DETECT) INSIDE SECTION OF CONTROL BOX DS TH1 TH2 TH5 1 B B L L U U 3 CN31 1 2 1 2 CN22 (BLU) CN20 (RED) I.B. 1 2 1 2 3 1 2 3 4 5 6 7 8 9 1 2 3 4 1 2 12 3 4 5 1 2 3 CN21 CN29 (WHT) (BLK) CN31 (WHT) CN90 (WHT) CN41 (WHT) CN24 (YLW) CN51 (WHT) CN32 (WHT) 1 2 1 2 SW1 CN2L (RED) SW2 SWE ON OFF LED1 LED2 LED3 WHT BLK 2 1 X1 (BLU) CN3C ZNR W3B1 H L T K O3Y 1 R L N W W B H L T K TO MA-REMOTE CONTROLLER DC8.7-13V W H T 2 1 B L K 3 2 1 wA X4 X1 FUSE (ORN) CND O3B 1 R R N N TB5 BL U B 2 L 1 U X4 X5 X6 X5 CN2D (WHT) CN2S (WHT) (RED) CNDK P.B. 3 1 (BLU) CNP (WHT) FAN W P P B H N N L T K K K <PEAD-RP35•50•60EA, 35EA2> External static pressure 30Pa <PEAD-RP71•100•125•140EA, 100EA2> External static pressure 70Pa DP <PEAD-RP35•50•60EA, 35EA2> External static pressure 70Pa 1 CNSK (RED) X6 7 5 3 1 Optional parts 1 2 3 4 5 6 Optional parts 1 2 3 4 5 6 (RED) 1 2 3 4 5 6 (RED) (WHT) TB4 S3 S2 S1 TO OUTDOOR UNIT BRN ORN YLW MF C MF C MODELS SW1 SW2 Model selection Capacity cord switch switch 12345 ON 35EA(2) OFF 12345 ON 50EA OFF 12345 ON 60EA OFF 12345 12345 ON ON 71EA OFF OFF 12345 ON 100EA(2) OFF 12345 ON 125EA OFF 12345 ON 140EA OFF <PEAD-RP71•100•125•140EA, 100EA2> External static pressure 130Pa <wA> (IN CASE OF CONNECT THE REPLACEMENT WIRING) L N 1 2 1 2 TO CND S1 S2 S3 1 2 POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT TO CN3C NOTE 1.SINCE THE OUTDOOR SIDE ELECTRIC WIRING MAY CHANGE BE SURE TO CHECK THE OUTDOOR UNIT ELECTRIC WIRING FOR SERVICING. 2.INDOOR AND OUTDOOR CONNECTING WIRES ARE MADE WITH POLARITIES, MAKE WIRING MATCHING TERMINAL NUMBERS(S1,S2,S3). 3.SYMBOLS USED IN WIRING DIAGRAM ABOVE ARE, : CONNECTOR, : TERMINAL. 4.THE WIRING BETWEEN MA-REMOTE CONTROLLER AND TB5 IS INCLUDED IN THE PACKAGE. 44 OCS05A-2.qxp 06.5.15 0:52 PM Page 45 PEAD-RP60GA SYMBOL I.B. FUSE ZNR CN2L CN24 CN32 CN41 CN51 CN90 LED1 LED2 LED3 PEAD-RP71GA PEAD-RP100GA NAME NAME SYMBOL INDOOR CONTROLLER BOARD SW1 SWITCH(MODEL SELECTION) FUSE(T6.3AL250V) SW2 SWITCH(CAPACITY CORD) VARISTOR SWE SWITCH(EMERGENCY OPERATION) CONNECTOR(LOSSNAY) X1 RELAY(DRAIN PUMP) X4 RELAY(FAN MOTOR) CONNECTOR(HEATER) CONNECTOR(REMOTE SWITCH) X5 RELAY(FAN MOTOR) CONNECTOR(HA TERMINAL-A) X6 RELAY(FAN MOTOR) CONNECTOR(CENTRALLY CONTROL) P.B. INDOOR POWER BOARD C CAPACITOR(FAN MOTOR) CONNECTOR(WIRELESS) POWER SUPPLY(I.B.) MF FAN MOTOR POWER SUPPLY(REMOTE CONTROLLER) TB4 TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE) TRANSMISSION(INDOOR•OUTDOOR) NAME SYMBOL TERMINAL BLOCK(REMOTE CONTROLLER) TB5 TH1 INTAKE AIR TEMP.THERMISTOR (0: /15t,25:/5.4t DETECT) TH2 PIPE TEMP. THERMISTOR/LIQUID (0: /15t,25:/5.4t DETECT) TH5 COND./EVA. TEMP. THERMISTOR (0: /15t,25:/5.4t DETECT) INSIDE SECTION OF CONTROL BOX TH1 TH2 TH5 1 2 1 2 1 2 1 2 CN22 (BLU) CN20 (RED) CN21 (WHT) CN29 (BLK) B B L L U U I.B. 1 2 3 1 2 3 4 5 6 7 8 9 1 2 3 4 CN90 (WHT) CN41 (WHT) CN31 (WHT) 1 2 CN24 (YLW) 1 2 3 4 5 1 2 3 CN51 (WHT) CN32 (WHT) 1 2 SW1 CN2L (RED) SW2 SWE ON LED1 LED2 LED3 OFF X1 2 1 WHT BLK (BLU) CN3C O3B1 R R N N ZNR TO MA-REMOTE CONTROLLER DC8.7-13V (ORN) CND W3B1 H L T K O3Y1 R L N W W H T wA 2 1 B L K 3 2 1 U B L U 2 1 X1 FUSE W B H L T K TB5 BL X4 X5 X6 X5 CN2D (WHT) CN2S (WHT) (RED) CNDK 3 1 (BLU) CNP X4 X6 7 5 3 1 B B O L L R U K G CNSK (RED) 1 2 3 4 5 6 1 TO OUTDOOR UNIT (WHT) MF C THE REPLACEMENT WIRING) L N 1 2 1 2 TO CND S1 S2 S3 1 2 TO CN3C POWER SUPPLY ~(1PHASE) 230V 50Hz MODELS SW1 SW2 Model selection Capacity cord switch switch 12345 ON OFF 60GA 12345 12345 TO OUTDOOR UNIT 230V 240V BLU 5Pa 10Pa 20Pa WHT 35Pa 50Pa 60Pa RED 50Pa 70Pa 75Pa (FACTORY SHIPMENT) BRN ORN YLW <wA> (IN CASE OF CONNECT *External static pressure CONNECTOR COLOR 220V * P.B. TB4 S3 S2 S1 (WHT) FAN G Y Y B R L L L Y W W K 71GA ON OFF ON OFF 12345 ON OFF 100GA NOTE 1.SINCE THE OUTDOOR SIDE ELECTRIC WIRING MAY CHANGE BE SURE TO CHECK THE OUTDOOR UNIT ELECTRIC WIRING FOR SERVICING. 2.INDOOR AND OUTDOOR CONNECTING WIRES ARE MADE WITH POLARITIES, MAKE WIRING MATCHING TERMINAL NUMBERS(S1,S2,S3). 3.SYMBOLS USED IN WIRING DIAGRAM ABOVE ARE, : CONNECTOR, : TERMINAL. 4.THE WIRING BETWEEN MA-REMOTE CONTROLLER AND TB5 IS INCLUDED IN THE PACKAGE. 45 06.5.15 0:52 PM PKA-RP35GAL Page 46 PKA-RP50GAL P.B CNDK (RED) CN2S (WHT) 1 2 DC13.1V 3 MF w1 (Fig.1) 1 2 TB2 TB4 YLW S1 S2 ORN S3 ORN BRN 1 2 3 BLK WHT POWER POWER 1 2 1 3 VANE CNDK 1 3 CND 1 3 CN6V INDOOR/OUTDOOR (GRN) (RED) (ORN) POWER CN2D(WHT) COMMUNICATION CN3C(BLU) X4 BCR ZNR X4 CN41 CN2L CN51 CN32 TO OUTDOOR UNIT I.B 6 FUSE FAN 1 3 5 (WHT) YLW ORN I.B RED WHT RED WHT BLK C RED BLU GRN/YLW MV POWER SUPPLY ~(1PHASE) 230V 50Hz L N YLW TB4S1 ORN S2 ORN S3 BRN YLW ORN OCS05A-2.qxp 1 3 TO OUTDOOR UNIT 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) 9 WIRELESS CN90 (WHT) LED3 LED2 LED1 SW2 SWE ON OFF SW1 INTAKE CN20 (RED) LIQUID PIPE CN21 CN29 (WHT) (BLK) 1 2 1 2 1 2 CNB BZ REMOCON CN22 (BLU) RU RECEIVER LED1 LED2 SW2 SW1 1 2 W.B Refer to tables 1 and 2 for service PCB. R.B 2 1 TH2 TH1 TH5 TRANSMISSION WIRES DC12V 1 TB6 2 TB5 PKH-P35,50GALH models only 1 2 H1 YLW YLW I.B HEATER CN24 (YLW) 6 RED 88H 1 GRY 6 5 RED SW1 Service board 1 2 3 4 5 SYMBOL P.B I.B FUSE ZNR CN2L CN32 CN41 CN51 SW1 SW2 SWE X4 BCR LED1 LED2 LED3 ON OFF FS1 FS2 26H 88H RED WHT 1 2 RED 5 TB2 L 3 RED N BLU GRN/YLW MODELS PKA-RP35GAL PKH-P35GALH NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE (T6.3AL250V) VARISTOR CONNECTOR <LOSSNAY> CONNECTOR <REMOTE SWITCH> CONNECTOR <HA TERMINAL-A> CONNECTOR <CENTRALLY CONTROL> SWITCH <MODEL SELECTION>wSee Table 1. SWITCH <CAPACITY CODE>wSee Table 2. SWITCH <EMERGENCY OPERATION> RELAY <FAN MOTOR> FAN CONTROL ELEMENT POWER SUPPLY <I.B> POWER SUPPLY <R.B> TRANSMISSION <INDOOR-OUTDOOR> Please set the voltage using the remote controller. For the setting method,please refer to the indoor unit Installation Manual. POWER SUPPLY ~(1PHASE) 230V 50Hz SW2 Service board MODELS Service board 1 2 3 4 5 1 2 3 4 5 SYMBOL C MF MV TB2 TB4 TB5,TB6 TH1 TH2 TH5 ON OFF PKA-RP50GAL PKH-P50GALH NAME CAPACITOR <FAN MOTOR> FAN MOTOR VANE MOTOR TERMINAL BLOCK (HEATER) wPKH-P.GALH models only or option for PKA-RP.GAL models. TERMINAL BLOCK <INDOOR/ OUTDOOR CONNECTING LINE> TERMINAL BLOCK <REMOTE CONTROLLER TRANSMISSION LINE> <OPTION> ROOM TEMP.THERMISTOR <0:/ 15k", 25:/ 5.4k" DETECT> PIPE TEMP.THERMISTOR/ LIQUID <0:/ 15k", 25:/ 5.4k" DETECT> COND./ EVA.TEMP.THERMISTOR <0:/ 15k", 25:/ 5.4k" DETECT> SYMBOL W.B RU BZ LED1 LED2 SW1 SW2 R.B HEATER FS1 FS2 H1 26H 88H ON OFF NAME WIRELESS REMOTE CONTROLLER BOARD RECEIVING UNIT BUZZER LED <RUN INDICATOR> LED <HOT ADJUST> SWITCH (HEATING ON/ OFF> SWITCH (COOLING ON/ OFF> WIRED REMOTE CONTROLLER BOARD THERMAL FUSE <104:10A> THERMAL FUSE <84:10A> HEATER HEATER THERMAL SWITCH HEATER CONTACTOR NOTES: 1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 2. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1, S2, S3). 3. Make sure that the main power supply of the booster heater is independent. 4. Symbols used in wiring diagram above are, : Connector, : Terminal (block). w1. When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig 1. w2. For power supply system of this unit, refer to the caution label located near this diagram. 46 Page 47 PKA-RP60FAL SYMBOL P.B I.B FUSE ZNR CN2L CN32 CN41 CN51 SW1 SW2 SWE X4 BCR LED1 LED2 LED3 PKA-RP71FAL SYMBOL C MF MV TB2 NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE(T6.3AL250V) VARISTOR CONNECTOR(LOSSNAY) CONNECTOR(REMOTE SWITCH) CONNECTOR(HA TERMINAL-A) CONNECTOR(CENTRALLY CONTROL) SWITCH (MODEL SELECTION) wSee Table 1. SWITCH (CAPACITY CODE) wSee Table 2. SWITCH(EMERGENCY OPERATION) RELAY(FAN MOTOR) FAN CONTROL ELEMENT POWER SUPPLY(I.B) POWER SUPPLY(R.B) TRANSMISSION(INDOOR-OUTDOOR) NAME CAPACITOR(FAN MOTOR) FAN MOTOR VANE MOTOR TERMINAL BLOCK (HEATER) wPKH-P.FALH models only or option for PKA-RP.FAL models. TERMINAL BLOCK(INDOOR/OUTDOOR CONNECTING LINE) TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE )(OPTION) ROOM TEMP.THERMISTOR (0;/15k', 25;/5.4k' DETECT) PIPE TEMP.THERMISTOR/LIQUID (0;/15k', 25;/5.4k' DETECT) COND./EVA.TEMP.THERMISTOR (0;/15k', 25;/5.4k' DETECT) TB4 TB5 TH1 TH2 TH5 P.B CNDK (RED) 1 2 TB4 YLW S1 S2 ORN S3 ORN BRN 1 2 3 FAN 1 3 5 X4 BCR POWER POWER 1 2 1 3 VANE CNDK 1 3 CND 1 3 CN6V INDOOR/OUTDOOR (GRN) (RED) (ORN) POWER CN2D(WHT) COMMUNICATION CN3C(BLU) ZNR X4 CN41 CN2L CN51 CN32 NAME WIRELESS REMOTE CONTROLLER BOARD RECEIVING UNIT BUZZER LED(RUN INDICATOR ) LED(HOT ADJUST) SWITCH(HEATING ON/OFF) SWITCH(COOLING ON/OFF) WIREDREMOTE CONTROLLER BOARD(OPTION) TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE) HEATER FS1,2 THERMAL FUSE(117; 10A:60,71FALH/ 117; 16A:100FALH) HEATER H1 26H HEATER THERMAL SWITCH 88H HEATER CONTACTOR w1 (Fig.1) TB2 RED BLU GRN/YLW TO OUTDOOR UNIT I.B 6 FUSE (WHT) BLK WHT RED WHT RED WHT BLK C I.B SYMBOL W.B RU BZ LED1 LED2 SW1 SW2 R.B TB6 Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual CN2S (WHT) 1 2 DC13.1V 3 MF PKA-RP100FAL 1 3 MV L N POWER SUPPLY (1PHASE) 230V 50Hz YLW TB4S1 ORN S2 ORN S3 BRN YLW ORN 06.5.15 0:52 PM YLW ORN OCS05A-2.qxp TO OUTDOOR UNIT 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) 9 WIRELESS CN90 (WHT) LED3 LED2 LED1 SWE ON OFF SW2 SW1 INTAKE LIQUID PIPE CN20 CN21 CN29 (RED) (WHT) (BLK) 1 2 1 2 1 2 CNB BZ REMOCON CN22 (BLU) RU RECEIVER LED1 LED2 SW2 SW1 1 2 W.B Refer to tables 1 and 2 for service PCB. R.B 2 1 TH2 TH1 Table 1 SW1 Service board 1 2 3 4 5 ON OFF Service board MODELS 1 2 3 4 5 PKA-RP60FAL PKH-P60FALH HEATER PKA-RP71FAL ON OFF PKH-P71FALH YLW YLW RED 1 1 2 3 4 5 MODELS PKA-RP100FAL ON OFF PKH-P100FALH Service board 1 2 3 4 5 ON OFF P100FALH models only FS1 88H SW2 Service board MODELS H1 CN24 1 2 (YLW) 6 1 TB6 2 TRANSMISSION WIRES DC12V TB5 Table 2 PKH-P60 I.B TH5 6 GRY 5 RED FS2 26H 88H RED WHT 1 2 RED 5 TB2 L 3 RED N BLU GRN/YLW NOTES: 1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 2. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1, S2, S3). 3. Make sure that the main power supply of the booster heater is independent. 4. Symbols used in wiring diagram above are, : Connector, : Terminal (block). w1. When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig 1. w2. For power supply system of this unit, refer to the caution label located near this diagram. 47 POWER SUPPLY (1PHASE) 230V 50Hz OCS05A-2.qxp 06.5.15 0:52 PM Page 48 PCA-RP50GA PCA-RP60GA PCA-RP71GA PCA-RP100GA PCA-RP125GA PCA-RP140GA NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE (T6.3AL250V) VARISTOR CONNECTOR(LOSSNAY) CONNECTOR(REMOTE SWITCH) CONNECTOR(HA TERMINAL-A) CONNECTOR(CENTRALLY CONTROL) SWITCH (MODEL SELECTION) WSee Table 1. SWITCH (CAPACITY CODE) WSee Table 2. SWITCH(EMERGENCY OPERATION) RELAY(DRAIN PUMP) RELAY(FAN MOTOR) FAN CONTROL ELEMENT POWER SUPPLY(I.B) POWER SUPPLY(R.B) TRANSMISSION(INDOOR-OUTDOOR) CAPACITOR(FAN MOTOR) SYMBOL MF MV DP DS TB2 TB4 TB5,TB6 TH1 TH2 TH5 R.B P.B CNDK (RED) C BRN ORN YLW ORN RED WHT RED WHT BLK FUSE D.U.M 1 3 POWER 1 3 POWER 1 3 1 2 1 3 VANE CND CNDK CNP 6 INDOOR/OUTDOOR (CN6V) POWER (ORN) (RED) (BLU) CN2D(WHT) COMMUNICATION GRN CN3C(BLU) X4 X1 CN41 CN2L WIRELESS ZNR CN90 CN51 CN32 (WHT) X4 X1 LED3 LED2 LED1 D.SENSOR INTAKE LIQUID PIPE CN31 CN20 CN21 CN29 (WHT) (RED) (WHT) (BLK) SW1 1 2 1 2 1 2 BLK BLK 1 2 3 Refer to tables 1 and 2 for service PCB. REMOCON CN22 (BLU) TB4 S1 S2 S3 MV MV 9 100~140 TYPE 5 5 MV CNB Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual. RU RECEIVER LED1 LED2 SW2 SW1 W.B 2 1 TO OUTDOOR UNIT 50~71 TYPE 6 6 6 BZ 1 2 BLU BLU SW2 BLK BLK BCR SWE ON OFF YLW ORN ORN BRN DP FAN 1 3 5 (WHT) THERMAL FUSE(98;10A:50GAH/117;16A:100GAH 110;16A:60,71,125,140GAH) HEATER HEATER THERMAL SWITCH HEATER CONTACTOR 1 2 (OPTION) 1 2 3 I.B H1 26H 88H NAME WIRELESS REMOTE CONTROLLER BOARD(OPTION) RECEIVING UNIT BUZZER LED(RUN INDICATOR) LED(HOT ADJUST) SWITCH(HEATING ON/OFF) SWITCH(COOLING ON/OFF) CN2S (WHT) 1 2 DC13.1V 3 MF SYMBOL W.B RU BZ LED1 LED2 SW1 SW2 HEATER FS1,2 NAME FAN MOTOR VANE MOTOR DRAIN-UP MACHINE (OPTION) DRAIN SENSOR (OPTION) TERMINAL BLOCK (HEATER) WPCH-P.GAH models only or option for PCA RP.GA models. TERMINAL BLOCK(INDOOR/OUTDOOR CONNECTING LINE) TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE ) ROOM TEMP.THERMISTOR (0;/15k', 25;/5.4k' DETECT) PIPE TEMP.THERMISTOR/LIQUID (0;/15k', 25;/5.4k' DETECT) COND./EVA.TEMP.THERMISTOR (0;/15k', 25;/5.4k' DETECT) WIRED REMOTE CONTROLLER BOARD BLK WHT SYMBOL P.B I.B FUSE ZNR CN2L CN32 CN41 CN51 SW1 SW2 SWE X1 X4 BCR LED1 LED2 LED3 C TRANSMISSION WIRES DC12V 1 2 1 2 WWhen installing optional TB5 drain-up machine disconnect R.B the CN31 jumper connector 1 2 and replace it with the CN31 TB6 TH2 TH1 TH5 DRAIN SENSOR drain sensor (DS). [Servicing] (WHT) 1 2 3 When installing drain-up Fasten terminal of the terminal board "TB4"equips lock system. machine (Optional part). To remove the fastened terminal, pull it while pressing the protruding DS portion (locking lever) of the terminal. The fastened terminal protruding portion should face upward. H1 FS1 FS2 88H RED WHT 1 2 RED 5 W1 (Fig.1) TB2 L 3 RED N BLU POWER SUPPLY ~(1PHASE) 230V 50Hz GRN/YLW W1. When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig 1. W2. For power supply system of this unit, refer to the caution label located near this diagram. 1 2 HEATER CN24 (YLW) I.B YLW YLW I.B RED 6 6 1 GRY 5 RED 88H Table 2 SW2 Table 1 MODELS PCA-RP.GA PCH-P.GAH SW1 Service board 1 2 3 4 5 ON OFF MODELS Service board PCA-RP50GA PCH-P50GAH 1 2 3 4 5 PCA-RP60GA PCH-P60GAH 1 2 3 4 5 PCA-RP71GA PCH-P71GAH 1 2 3 4 5 MODELS Service board PCA-RP100GA 1 2 3 4 5 PCA-RP125GA 1 2 3 4 5 PCA-RP140GA 1 2 3 4 5 ON OFF PCH-P100GAH ON OFF PCH-P125GAH ON OFF PCH-P140GAH TB2 RED BLU GRN/YLW ON OFF ON OFF 26H 1 3 L N YLW TB4S1 ORN S2 ORN S3 BRN YLW ORN PCH-P50~P140GAH models only POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) NOTES: 1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 2. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1, S2, S3). 3. Make sure that the main power supply of the booster heater is independent. 4. Symbols used in wiring diagram above are, : Connector, : Terminal (block). ON OFF 48 OCS05A-2.qxp 06.5.15 0:52 PM PCA-RP71HA Page 49 PCA-RP125HA [ LEGEND ] SYMBOL P. B I. B FUSE ZNR CN2L CN32 CN41 CN51 LED1 LED2 LED3 X1 X4 X5 X6 SW1 SW2 NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE (T6.3AL250V) VARISTOR CONNECTOR (LOSSNAY) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROLL) POWER SUPPLY (I. B) POWER SUPPLY (R. B) TRANSMISSION(INDOOR-OUTDOOR) RELAY (DEW PREVENTION HEATER) RELAY(FAN MOTOR) RELAY(FAN MOTOR) RELAY(FAN MOTOR) SWITCH (MODEL SELECTION) See Table 1. SWITCH (CAPACITY CODE) See Table 2. SYMBOL MF1, MF2 C1, C2 H2 TB2 NAME FAN MOTOR CAPACITOR(FAN MOTOR) DEW PREVENTION HEATER TERMINAL BLOCK(INDOOR UNIT POWER (OPTION)) TB4 TERMINAL BLOCK(INDOOR/OUTDOOR TB5,TB6 CONNECTING LINE) TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE) ROOM TEMP.THERMISTOR (0˚C/15kΩ, 25˚C/5.4kΩ DETECT) TH1 TH2 PIPE TEMP.THERMISTOR/LIQUID (0˚C/15kΩ, 25˚C/5.4kΩ DETECT) TH5 COND./ EVA.TEMP.THERMISTOR (0˚C/15kΩ, 25˚C/5.4kΩ DETECT) R. B WIRED REMOTE CONTROLLER BOARD SWITCH (EMERGENCY OPERATION) SWE For PCA-RP125HA 1 1 I.B FAN 1 3 5 7 (WHT) DC13.1V TB4 S1 S2 S3 YLW ORN ORN BRN FUSE CN41 ZNR LED3 LED2 LED1 INTAKE LIQUID CN20 CN21 (RED) (WHT) 1 2 1 2 BLK BLK 1 2 WHT WHT Refer to tables 1 and 2 for service PCB. PIPE REMOCON CN29 CN22 (BLK) (BLU) BLU BLU SW1 1 2 1 2 1 3 TH2 TH5 TH1 ON OFF YLW ORN ORN CN2L I.B YLW ORN CN51 CN32 ON OFF Table 1 SW1 Service board 1 2 3 4 5 w1 (Fig.1) D.HEATER 1 3 ROWER 1 3 ROWER 1 3 1 2 1 3 CNC CNDK CND ROWER INDOOR/OUTDOOR COMMUNICATION (RED) (RED) (ORN) CN2D(WHT) CN3C(BLU) X6 X5 X4 SW2 TO OUTDOOR UNIT RED BLU GRN/YLW X6 X5 X4 SWE Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual. 1 2 BLK WHT H2 1 2 3 YLW ORN BRN C2 GRY CN2S (WHT) (RED) YLW YLW ORN C1 RED P.B CNDK RED WHT 6 5 4 3 2 1 BLK BLU YLW WHT 6 5 4 3 2 1 BLK BLU YLW WHT ORN RED BLK BLU YLW WHT MF2 ORN RED BLK BLU YLW WHT MF1 1 3 BRN PCA-RP71HA TB5 2 TRANSMISSION WIRES DC12V 1 SW2 MODELS Service board Service board 1 2 3 4 5 1 2 3 4 5 ON PCA-RP125HA ON OFF OFF NOTES: 1.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3). 3.Symbols used in wiring diagram above are, : Connector, : Terminal (block). 1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1. 2 ; For power supply system of this unit, refer to the caution label located near this diagram. 49 POWER SUPPLY ~(1PHASE) 230V 50Hz TB4 S1 S2 S3 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) Table 2 MODELS TB2 L N R.B 1 TB6 2 TO OUTDOOR UNIT OCS05A-2.qxp 06.5.15 0:52 PM PSA-RP71GA SYMBOL P.B I.B FUSE ZNR CN2L CN32 CN41 CN51 LED1 LED2 LED3 Page 50 PSA-RP100GA NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE (T6.3AL250V) VARISTOR CONNECTOR (LOSSNAY) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROL) POWER SUPPLY (I.B) POWER SUPPLY (R.B) TRANSMISSION (INDOOR-OUTDOOR) SYMBOL I.B SW1 SW2 SWE X2 X4 X5 X6 R.B TB6 HEATER FS1,2 H 26H 88H PSA-RP125GA NAME SWITCH (MODEL SELECTION) See Table 1. SWITCH (CAPACITY CODE) See Table 2. SWITCH (EMERGENCY OPERATION) RELAY (LOUVER) RELAY (FAN MOTOR) RELAY (FAN MOTOR) RELAY (FAN MOTOR) WIRED REMOTE CONTROLLER BOARD TERMINAL BLOCK (REMOTE CONTROLLER TRANSMISSION LINE) THERMAL FUSE (110˚C16A) HEATER HEATER THERMAL SWITCH HEATER CONTACTOR PSA-RP140GA SYMBOL C MF ML NAME CAPACITOR (FAN MOTOR) FAN MOTOR LOUVER MOTOR TB2 TERMINAL BLOCK (HEATER) PSH-P.GAH models only or option for PSA-RP.GA models. TB4 TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE) TH1 ROOM TEMP.THERMISTOR (0˚C/15kΩ, 25˚C/5.4kΩ DETECT) TH2 PIPE TEMP.THERMISTOR/LIQUID (0˚C/15kΩ, 25˚C/5.4kΩ DETECT) TH5 COND./EVA.TEMP.THERMISTOR (0˚C/15kΩ, 25˚C/5.4kΩ DETECT) INDOOR UNIT TB4 YLW S1 P.B CNSK (RED) CN2S (WHT) 2 1 ORN S2 3 2 1 DC13.1V S3 Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual. TO OUTDOOR UNIT TB2 1 (Fig.1) ORN MF RED BLU GRY/YLW ML C 2 1 2 1 2 1 X2 X6 X5 X4 LED3 LED2 LED1 SW2 SWE ON SW1 OFF CN24 TH2 Refer to tables 1 and 2 for service PCB. R.B 2 1 I.B YLW YLW 1 TB6 TH5 88H 6YLW FS2 6 5 RED 26H RED FS1 RED WHT H 1 2 TB4 S1 S2 S3 I.B POWER SUPPLY ~(1PHASE) 230V 50Hz 1 3 1 3 TO OUTDOOR UNIT POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) BLU 2 HEATER CN24 (YLW) RED BLU LIQUID WIRELESS CN21 CN90 (WHT) (WHT) INTAKE CN20 REMOCON 2 (RED) CN22 (BLU) 1 PIPE CN29 (BLK) CN2L CN41 CN32 1 TH1 PSH -P.GAH models only 1 3 INDOOR/OUTDOOR COMMUNICATION CN3C (BLU) BRN ORN X6 X5 X4 CN51 ZNR 1 2 POWER CN2D (WHT) YLW ORN X2 POWER 1 3 CND (ORN) L N BRN ORN POWER 1 3 CNDK (RED) BLK WHT RED WHT LOUVER 1 3 CNL (YLW) YLW ORN YLW YLW FAN 1 3 5 7 (WHT) I.B FUSE BLK BLU YLW WHT RED BLU TRANSMISSION WIRES DC12V RED 5 88H TB2 3 RED L BLU N GRN/YLW POWER SUPPLY ~(1 PHASE) 230V 50Hz Table 1 SW2 Service board 1 2 3 4 5 PSA-RP.GA ON PSH-P.GAH OFF MODELS Table 2 SW2 Service board 1 2 3 4 5 PSA-RP71GA ON PSH-P71GAH OFF MODELS PSA-RP100GA PSH-P100GAH 1 2 3 4 5 PSA-RP125GA PSH-P125GAH 1 2 3 4 5 PSA-RP140GA PSH-P140GAH 1 2 3 4 5 1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1. 2 ; For power supply system of this unit, refer to the caution label located near this diagram. [NOTES] 1.Symbols used in wiring diagram above are, : Connector, : Terminal (block). 2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3). 3.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 4.This diagram shows the wiring of Indoor and Outdoor connecting wires (specification of 230V), adopting superimposed system of power and signal. ON OFF ON OFF ON OFF 50 06.5.15 0:52 PM Page 51 PUHZ-RP35VHA2 PUHZ-RP50VHA2 Symbols used in wiring diagram above are, SYMBOL TB1 MC MF1 21S4 63H SV TH3, TH33 TH4 TH6 TH7 TH8 LEV(A),LEV(B) ACL P.B. R/S U/V/W IPM CB1~CB3 :Connector, NAME Terminal Block<Power Supply, Indoor/Outdoor> Motor for Compressor Fan Motors Solenoid Valve (Four-Way Valve) High Pressure Switch Solenoid Valve (Bypass Valve) Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Radiator Panel> Electronic Expansion Valve Reactor Power Circuit Board Connection Terminal<L/N-Phase> Connection Terminal<U/V/W-Phase> Inverter Main Smoothing Capacitor PUHZ-RP60VHA2 PUHZ-RP71VHA2 :Terminal(block) SYMBOL N.F. LI/LO NI/NO E 52C C.B. SW1 SW4 SW5 SW6 SW7 SW8 SW9 SW10 LED1,LED2 F1~4 NAME Noise Filter Circuit Board Connection Terminal<L-Phase> Connection Terminal<N-Phase> Connection Terminal<Ground> 52C Relay Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant Address> Switch<Test Operation> Switch<Function Switch> Switch<Model Select> Switch<Function Setup> Switch Switch Switch<Model Select> Light Emitting Diodes <Operation Inspection Indicators> Fuse<T6.3AL250V> SYMBOL SWP CN31 SS CNM CNMNT NAME Switch<Pump Down> Connector<Emergency Operation> Connector<Connection for Option> Connector<A-Control Service Inspection Kit> Connector <Connected to Optional M-NET Adapter Board> Connector CNVMNT <Connected to Optional M-NET Adapter Board> Connector CNDM < Connected for Option (Contact Input)> X51,X52,X55 Reray TH7 TH6 12 TH33 (YLW) 1234 TH7/6 (RED) TH3 TH4 LEV-A LEV-B SW11 SW1 LED2 SW7 3 CN52C (RED) 12 A CNS (WHT) 3 2 1 12 34 F1 CNAC (WHT) F4 21S4 1 (GRN) 3 21S4 SV2 1 (BLU) 3 3 SS 1 (WHT) SV ACL LO NO N.F. S W CN3 (WHT) CN2 (WHT) CB2 CB3 3 1 CB1 CNAC2 (RED) TH8 21 V 3 12 CN4 (WHT) U R CN5 (RED) 1 I PM 21 PFC 52C CN52C (BLK) 7 6 54 3 2 1 RED w2 U BLK WHT P.B. 1 2 MC W V CNAC1 (WHT) w1 MODEL SELECT ON OFF 1 2 3 4 5 6 50V ON OFF 60V ON OFF ON OFF 1 2 3 4 5 6 1 2 TB1 ON OFF 1 2 3 4 5 6 71V (RED) CN5 1 2 ON OFF L 1 2 ON OFF 1 2 3 4 5 6 N S1 S2 S3 NO FUSE BREAKER 1 2 POWER SUPPLY ~/N 230V 50Hz w2 RP60/71V only INDOOR UNIT M-NET ADAPTER SYMBOL TB7 CN5 CND CN2M SW1 SW11 NAME Terminal Block<M-net connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting : 1st digit> SYMBOL SW12 LED1 LED2 LED3 LED4 LED5 NAME Switch<Address setting : 2nd digit> LED<Power Supply : DC5V> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Recelving> LED<Power Supply : DC12V> 51 NI ON OFF SW10 E 35V SW6 LI MODEL S TB7 M-NET X51 X52 F3 X55 F2 B 1 2 LED1 12 CN2M (WHT) wh 1 CN51 (WHT) 12345 CN4 (WHT) 21 CNDM (WHT) 1 CN2 (WHT) 1234567 LED5 SW10 CN31 TRANS CNDC (PNK) M-NET SUBSTRATE SW9 SW6 SW5 SW1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CNM (WHT) LED4 123 63H (YLW) F5 SW4 SWP SW8 MF1 123456 123 12345 LEV-B CNVMNT CNMNT (RED) (WHT) (WHT) SW12 LED3 w1 123456 LEV-A (WHT) 12 12 TH3 TH4 (WHT) (WHT) LED1 CNF1 (WHT) LED2 4567 1 1 CND (WHT) TH33 C.B. 12345 CN5 (WHT) When M-NET adaptor is connected 3 OCS05A-2.qxp 123 PUHZ-RP100VHA2 PUHZ-RP125VHA2 Symbols used in wiring diagram above are, SYMBOL TB1 MC MF1,MF2 21S4 SV 63H TH3 TH4 TH6 TH7 TH8 TH33 LEV-A,B DCL 52C RS ACTM CB Page 52 :Connector, NAME Terminal Block<Power Supply, Indoor/Outdoor > Motor for Compressor Fan Motors Solenoid Valve (Four-Way Valve) Solenoid Valve (Bypass Valve) High Pressure Switch Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Heat Sink> Thermistor<Outdoor Pipe> Electronic Expansion Valve Reactor 52C Relay Rush Current Protect Resistor Active Filter Module Main Smoothing Capacitor PUHZ-RP140VHA2 :Terminal(block) SYMBOL P.B. TABU/V/W TABS/T TABP1/P2/P TABN1/N2/N DS2,3 IPM N.F. LI/LO NI/NO EI C.B. F1~4 SW1 NAME Power Circuit Board Connection Terminal<U/V/W-Phase> Connection Terminal<L/N-Phase> Connection Terminal<DC Voltage> Connection Terminal<DC Voltage> Diode Bridge Power Module Noise Filter Circuit Board Connection Lead<L-Phase> Connection Lead<N-Phase> Connection Terminal<Ground> Controller Circuit Board Fuse<T6.3AL250V> Switch<Forced Defrost, Defect History Record Reset, Refrigerant Address> Switch<Test Operation> Switch<Function Switch> Switch<Model Select> SW4 SW5 SW6 TH33 TH7 TH6 TH3 TH4 LEV-A LEV-B 123456 123456 C.B. SYMBOL SW7 SW8 SW9 SW10 SWP CN31 LED1,LED2 SS CNM CNMNT CNVMNT CNDM NAME Switch<Function Setup> Switch Switch Switch<Model Select> Switch<Pump Down> Connector<Emergency Operation> Light Emitting Diodes <Operation Inspection Indicators> Connector<Connection for Option> Connector<A-Control Service Inspection Kit> Connector<Connected to Optional M-NET Adapter Board> Connector<Connected to Optional M-NET Adapter Board> Connector< Connected for Option (Contact Input)> When M-NET adaptor is connected SW11 SW1 LED2 3 SW7 SW9 SW6 CN31 F1 F4 3 52C 21S4 1 (GRN) 3 1 (BLK) 3 21S4 CNDM (WHT) 123 12345 TB7 A B S M-NET X51 CNAC (WHT) X52 F3 12 34 X53 F2 21 123 w1 CN51 (WHT) CN4 (WHT) X55 1 CN2 (WHT) 1234567 M-NET SUBSTRATE LED1 CNM (WHT) LED4 12 CN2M LED5 (WHT) 1 2 3 4 5 6 7 8 9 10 111213 14 TRANS CNDC (PNK) CNS (WHT) 3 2 1 LEV-B CNVMNT CNMNT (RED) (WHT) (WHT) SW10 63H (YLW) (WHT) MF2 F5 LEV-A (WHT) TH3 TH4 (WHT) (WHT) 12345 SW12 LED3 w1 123 SW1 TH7/6 (RED) 12 SW4 SWP SW8 SW5 TH33 (YLW) 12 LED1 4 5 6 7 CNF2 MF1 1234 LED2 1 (WHT) 12 1 4 5 6 7 CNF1 3 1 CND (WHT) 06.5.15 0:52 PM 12345 CN5 (WHT) OCS05A-2.qxp SV2 1 (BLU) 3 SS 1 (WHT) SV P.B. ~ + ~ N.F. DS3 TABS - ~ + ~ LO NO 1 2 CN5 (RED) NI EI - DS2 TABP1 (WHT) CNAC1 3 1 LI RED U V TABW 12 + TABV 12 (RED) CNAC2 3 1 TABN1 TABN2 BLK 12 TABP CB + TABU TABP2 CN3 (WHT) CN5 (RED) CN4 (WHT) TABN IPM WHT 1234567 + CN2 (WHT) - CNDC 1 3 (PNK) 123456 TH8 TABT CNAF (WHT) W MC TB1 L DCL N S1 S2 S3 L2 L1 RS 123456 + P - N1 N2 I ACTM SW6 ON 100V OFF NO FUSE BREAKER SW10 ON OFF 1 2 3 4 5 6 INDOOR UNIT ON 125V OFF 1 2 ON OFF 1 2 3 4 5 6 POWER SUPPLY ~/N 230V 50Hz ON 140V OFF NAME Terminal Block<M-net connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting : 1st digit> Switch<Address setting : 2nd digit> LED<Power Supply : DC5V> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Recelving> LED<Power Supply : DC12V> 52 1 2 ON OFF 1 2 3 4 5 6 M-NET ADAPTER SYMBOL TB7 CN5 CND CN2M SW1 SW11 SW12 LED1 LED2 LED3 LED4 LED5 w1MODEL SELECT MODEL 52C 1 2 OCS05A-2.qxp 06.5.15 0:52 PM Page 53 PUHZ-RP100YHA2 SYMBOL TB1 TB2 MC MF1,MF2 21S4 SV 63H TH3 TH4 TH6 TH7 TH33 LEV ACL1~ACL4 CB1,CB2 CK RS P.B. TB-U/V/W TB-L1/L2/L3 TB-P2 TB-C1 TB-N1 CT1, CT2 PUHZ-RP125YHA2 NAME Terminal Block(Power Supply ) Terminal Block(Indoor/Outdoor ) Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) Solenoid Valve (Bypass Valve) High Pressure Switch Thermistor(Outdoor Pipe) Thermistor(Discharge) Thermistor(Outdoor 2-Phase Pipe) Thermistor(Outdoor) Thermistor(Outdoor Pipe) Linear Expansion Valve Reactor Main Smoothing Capacitor Capacitor Rush Current Protect Resistor Power Circuit Board Connection Terminal(U/V/W-Phase) Connection Terminal(L1/L2/L3-Power Supply) Connection Terminal Connection Terminal Connection Terminal Current Trans SYMBOL N.F. LI1/LI2/LI3/NI LO1/LO2/LO3/NO GD1 CONV.B L1-A1/IN L1-A2/OU L2-A2/OU L3-A2/OU N-IN CK-OU C.B. F1,F2 F3,F4 SW1 SW4 SW5 SW6 SW7 SW8 SW9 SW10 SWP PUHZ-RP140YHA2 NAME Noise Filter Circuit Board Connection Terminal(L1/L2/L3/N-Power Supply) Connection Terminal(L1/L2/L3/N-Power Supply) Connection Terminal(Ground) Converter Circuit Board Connection Terminal(L1-Power Supply) Connection Terminal(L1-Power Supply) Connection Terminal(L2-Power Supply) Connection Terminal(L3-Power Supply) Connection Terminal Connection Terminal Controller Circuit Board FUSE(T6.3AL250V) FUSE(T6.3AL250V) Switch(Forced Defrost, Defect History Record Reset, Refrigerant Adress) Switch(Test Operation) Switch(Function Switch) Switch(Model Select) Switch(Function Switch) Switch(Function Switch) Switch(Function Switch) Switch(Model Select) Switch(Pump Down) SYMBOL CN31 21S4 SV2 SS LEV-A/LEV-B 63H TH3 TH4 TH7/6 TH33 CNF1/CNF2 LED1/LED2 CNM CNVMNT CNMNT CN3S CNDM CN51 NAME Connector(Emergency Operation) Connector(Four-Way Valve) Connector(Bypass Valve) Connector Connection for Option) Connector(LEV) Connector(High Pressure Switch) Connector(Thermistor) Connector(Thermistor) Connector(Thermistor) Connector(Thermistor) Connector(Fan Motor Operation) LED(Operatiion Inspection Indicators) Connector(A-Control Service Inspection Kit) Connector(Connect to Optional M-NET Adapter Board) Connector(Connect to Optional M-NET Adapter Board) Connector( Connection for Option) Connector( Connection for Option) Connector( Connection for Option) M-NET ADAPTER Terminal Block(M-NET connection ) Connector(Transmission) Connector(Power Supply) Connector(M-NET communication) Switch(Status of communication) Switch(Address setting: 1st digit) Symbols used in wiring diagram above are, SW12 LED1 LED2 LED3 LED4 LED5 : Connector, Switch(Address setting. 2nd digit ) LED(Power Supply: DC5V) LED(Connection to Outdoor Unit) LED(Transmission: Sending) LED(Transmission: Receiving) LED(Power Supply: DC12V) : Terminal(block) 63H TH4 SV2 1 (BLU) 3 12345 CN5 (WHT) SV (w1 MODEL SELECT) SW6 MODELS P.B. CT2 + TB-W BLK W TB-V WHT V 12 12 CN5 CN4 (RED) (WHT) + WHT TB-L1 RED 140Y ON OFF 1 2 3 4 5 6 1 2 1 2 3 4 5 6 ON OFF 1 2 TB-C1 TB-N1 CB1 CB2 CK CNAC1 1 (WHT) L1-A1 S3 N.F. 1 2 ON OFF 123 CN7 (WHT) TB-P2 S2 NO FUSE BREAKER 1 2 3 4 5 6 L3-OU BLK TB-L2 ON OFF RS TB2 S1 INDOOR UNIT - TB-L3 125Y CNCT 1 2 (RED) 3 SW10 ON OFF U RED TB-U CT1 MC ON OFF 1 3 CNAC2 (RED) L1-A2 1234567 CN2 (WHT) 100Y CK-OU 123 CN7 (WHT) CND (WHT) M-NET L2-A2 21S4 3 TB7 A B S SS 1 (WHT) L1-OU 3 21S4 1 (GRN) N-IN BLK F4 123 L2-OU F1 CNS (WHT) 3 2 1 w1 CONV.B. L1-IN F3 CNAC (WHT) 12 34 X55 F2 SW12 LED3 LED4 LED1 CNDC (PNK) CN4 (WHT) 21 LED2 L3-A2 1 CN2 (WHT) 1234567 SW11 SW1 12 CN2M LED5 (WHT) CN31 X51 TRANS SW9 SW7 w1 SW10 1 2 3 4 5 6 7 8 9 10 11121314 CNM SW6 123456 123 12345 LEV-B CNVMNT CNMNT (RED) (WHT) (WHT) 3 F5 123456 LEV-A (WHT) SW1 4 5 6 7 CNF2 (WHT) 12 12 TH3 TH4 (WHT) (WHT) LED1 1 1234 TH7/6 (RED) M-NET ADAPTER (OPTION) X52 MF2 12 TH33 (YLW) LED2 4 5 6 7 CNF1 1 2 3 (WHT) CN3N 63H (YLW) 3 1 1 MF1 LEV LEV C.B. CN51 CNDM CN3S (WHT) (WHT) (WHT) 12345 123 123 TH3 SW4 SWP SW8 SW5 TH33 TH7 TH6 BLU TB7 CN5 CND CN2M SW1 SW11 ACL1 TB1 L1 RED LI1 LO1 RED L2 WHT LI2 LO2 WHT L3 BLK LI3 LO3 BLK NI NO ACL2 POWER SUPPLY 3N~ 400V 50Hz ACL3 N BLU GD1 GD2 53 CNDC 1 (PNK) 3 3 1 CNL (BLU) BLU ACL4 OCS05A-2.qxp 5 06.5.15 0:52 PM Page 54 REFRIGERANT SYSTEM DIAGRAM 5-1. INDOOR UNIT PLA-RP·AA(2) PCA-RP·GA PKA-RP·GAL PKA-RP·FAL PEAD-RP·EA(2) PEAD-RP·GA PCA-RP·HA PSA-RP·GA Strainer(#50) Heat exchanger Refrigerant GAS pipe connection (Flare) Thermistor TH5 (Cond./Eva. temperature) Refrigerant flow in cooling Refrigerant flow in heating Refrigerant LIQUID pipe connection (Flare) Distributor with strainer(#50) Thermistor TH1 (Room temperature) Thermistor TH2 Pipe temperature (Liquid) Strainer(#50) 54 OCS05A-2.qxp 06.5.15 0:52 PM Page 55 5-2. OUTDOOR UNIT PUHZ-RP35VHA2 PUHZ-RP50VHA2 Heat exchanger Stop valve (with service port) Refrigerant GAS pipe connection(1/2F) Thermistor TH6 (Outdoor 2-phase pipe) Charge plug Solenoid valve (Four-way valve) Thermistor TH7 (Outdoor) Strainer #50 Thermistor TH3 (Outdoor pipe) Muffler Distributor High pressure switch 63H Thermistor TH4 (Discharge) Strainer #100 Thermistor TH33 (Outdoor pipe) Muffler Linear expansion valve B Compressor Power receiver Linear expansion valve A Stop valve Refrigerant LIQUID pipe connection(1/4F) Strainer #100 PUHZ-RP60VHA2 PUHZ-RP71VHA2 Heat exchanger Ball valve Refrigerant GAS pipe connection(5/8F) Strainer #50 Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor 2-phase pipe) 4-way valve Oil separator Bypass valve Charge plug (Low pressure) Charge plug (High pressure) Capillary tube O.D.4.0OI.D.2.4OL500 Capillary tube O.D.2.5OI.D.0.6OL1000 Thermistor TH3 (Outdoor pipe) Distributor High pressure switch 63H Strainer #100 Thermistor TH4 (Discharge) Strainer #100 Stop valve (with service port) Refrigerant LIQUID pipe connection(3/8F) Strainer #100 Power receiver Linear expansion valve B Thermistor TH33 (Outdoor pipe) Muffler Compressor Linear expansion valve A Strainer #100 Refrigerant flow in cooling Refrigerant flow in heating 55 OCS05A-2.qxp 06.5.15 0:52 PM Page 56 PUHZ-RP100VHA2 PUHZ-RP125VHA2 PUHZ-RP140VHA2 PUHZ-RP100YHA2 PUHZ-RP125YHA2 PUHZ-RP140YHA2 Heat exchanger Refrigerant GAS pipe connection(5/8F) Ball valve Strainer #50 Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor 2-phase pipe) Solenoid valve (Four-way valve) Charge plug (High pressure) Thermistor TH3 (Outdoor pipe) Muffler Charge plug (Low pressure) Distributor High pressure switch 63H Strainer #100 Thermistor TH4 (Discharge) Strainer #100 Thermistor TH33 (Outdoor pipe) Linear expansion valve B Stop valve (with service port) Refrigerant LIQUID pipe connection(3/8F) Strainer #100 Power receiver Strainer #100 Compressor Linear expansion valve A Restrictor valve Strainer #100 Strainer #100 Replace filter Solenoid valve (Bypass valve) Refrigerant flow in cooling Refrigerant flow in heating 56 OCS05A-2.qxp 06.5.15 0:52 PM 6 Page 57 PERFORMANCE CURVES FOR THE COMBINATION OF OUTDOOR UNIT PUHZ-RP•VHA2, PUHZ-RP100~140YHA2 Cooling capacity 1.4 Cooling capacity ratio Indoor intake air wet-bulb temperature <W.B. :> 1.2 22 1.0 20 18 0.8 0.6 16 -5 0 5 10 15 20 25 30 35 40 46 Outdoor intake air dry-bulb temperature <D.B. :> Cooling input 22 20 18 16 Cooling input ratio 1.2 1.0 0.8 0.6 Indoor intake air wet-bulb temperature <W.B. :> 0.4 -5 0 5 10 15 20 25 30 35 40 Outdoor intake air dry-bulb temperature <D.B. :> Note : This diagrams show the case where the operation frequency of a compressor is fixed. 57 46 OCS05A-2.qxp 06.5.15 0:53 PM Page 58 Heating capacity Indoor intake air dry-bulb temperature <D.B. :> Outdoor intake air wet-bulb temperature <W.B. :> Heating input Indoor intake air dry-bulb temperature <D.B. :> Outdoor intake air wet-bulb temperature <W.B. :> Note : This diagrams show the case where the operation frequency of a compressor is fixed. 58 OCS05A-2.qxp 06.5.15 0:53 PM 7 Page 59 CORRECTION FACTORS PUHZ-RP·VHA2, PUHZ-RP100~140YHA2 Cooling capacity correction factors Outdoor unit Refrigerant piping length (one way) 30m 40m 50m 55m 5m 10m 20m PUHZ-RP35VHA2 1.00 0.992 0.976 0.962 0.949 0.936 PUHZ-RP50VHA2 1.00 0.985 0.957 0.931 0.908 PUHZ-RP60VHA2 1.00 0.992 0.976 0.962 PUHZ-RP71VHA2 1.00 0.988 0.966 1.00 0.985 1.00 1.00 PUHZ-RP100VHA2 PUHZ-RP100YHA2 PUHZ-RP125VHA2 PUHZ-RP125YHA2 PUHZ-RP140VHA2 PUHZ-RP140YHA2 60m 70m 80m 0.930 — — — 0.886 0.876 — — — 0.949 0.936 0.930 — — — 0.946 0.929 0.913 0.905 — — — 0.957 0.931 0.908 0.886 0.876 0.865 0.846 0.829 0.981 0.946 0.914 0.885 0.858 0.845 0.834 0.812 0.792 0.976 0.931 0.893 0.858 0.827 0.813 0.800 0.775 0.753 60m 70m 80m Heating capacity correction factors 5m 10m 20m Refrigerant piping length (one way) 30m 40m 50m 55m PUHZ-RP35VHA2 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — PUHZ-RP50VHA2 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — PUHZ-RP60VHA2 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — PUHZ-RP71VHA2 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — 1.00 0.997 0.991 0.985 0.979 0.973 0.970 0.967 0.961 0.955 1.00 0.997 0.991 0.985 0.979 0.973 0.970 0.967 0.961 0.955 1.00 0.997 0.991 0.985 0.979 0.973 0.970 0.967 0.961 0.955 Outdoor unit PUHZ-RP100VHA2 PUHZ-RP100YHA2 PUHZ-RP125VHA2 PUHZ-RP125YHA2 PUHZ-RP140VHA2 PUHZ-RP140YHA2 59 OCS05A-2.qxp 06.5.15 0:53 PM 8 Page 60 APPLICABLE EXTENSION PIPE FOR EACH MODEL 8-1. PIPE LENGTH 8-1-1. 1:1 SYSTEM Pipe length <Table 1> Maximum pipe length Liquid pipe (mm) Gas pipe (mm) OD Thickness OD Thickness RP35•50 [6.35 t0.8 [9.52 [12.7 t0.8 t0.8 Standard size 30m w1 50m [30m] [30m] 10m [10m] RP60•71 [15.88 t1.0 w2 30m [30m] [12.7 t0.8 10m [10m] 30m [30m] [9.52 t0.8 [15.88 t1.0 w2 30m [20m] Standard size 50m [30m] Standard size 50m w3 [30m] 30m [20m] RP100~140 [19.05 t1.0 [12.7 t0.8 [19.05 [15.88 t1.0 t1.0 <Marks in the table> : It can be used. : Cooling capacity is lowered. : Additional refrigerant charge is required when the pipe length exceeds 10m. 50m [30m] 50m [20m] The maximum pipe length Charge-less pipe length 50m [30m] 30m [20m] 50m [20m] w1. Maximum pipe length is RP50, it becomes 10m. w2. Change the SW8-1 on the outdoor controller circuit board from OFF to ON. w3. The maximum length is 75m in case of new pipes. 8-1-2. TWIN AND TRIPLE SYSTEM (1) TWIN SYSTEM (2) TRIPLE SYSTEM <Table 2> Maximum pipe length <Table 3> Maximum pipe length RP71(RP35o2) Main pipe (mm) [A] Liquid pipe Gas pipe Liquid pipe [6.35 Gas pipe [12.7 [6.35 [12.7 Branch pipe Liquid pipe [9.52 (mm) Gas pipe [15.88 [B, C] Liquid pipe [12.7 Gas pipe RP100(RP50o2) [9.52 [9.52 [15.88 [15.88 Standard size Standard size 50m 50m w [30m] [30m] 50m [30m] [9.52 [19.05 [12.7 [19.05 50m [30m] 50m [20m] 50m [30m] 50m [20m] 50m [30m] RP125(RP60o2) • RP140(RP71o2) [9.52 [15.88 Standard size 50m w [30m] [9.52 [19.05 [12.7 [19.05 50m [30m] 50m [20m] RP140(RP50o3) Main pipe (mm) [A] ø9.52 ø9.52 ø15.88 ø19.05 Gas pipe Liquid pipe ø6.35 Standard size 50m w 50m Gas pipe ø12.7 [30m] [30m] Liquid pipe Branch pipe Liquid pipe ø9.52 (mm) Gas pipe ø15.88 [B, C, D] Liquid pipe ø12.7 50m [30m] 50m [20m] 50m [20m] Gas pipe ø19.05 [19.05 w The maximum length is 75m in case of new pipes. w The maximum length is 75m in case of new pipes. Indoor unit side Indoor unit side Indoor unit Indoor unit Indoor unit Indoor unit B h B h 50m [30m] ø12.7 ø19.05 C C D Indoor unit Distribution pipe Outdoor unit H H Outdoor unit Distribution pipe Outdoor unit side Outdoor unit side A A <TRIPLE SYSTEM> Total length A + B + C + D RP140: 75 m <TWIN SYSTEM> Total length A + B + C RP71 : 50 m RP100-140: 75 m 60 OCS05A-3.qxp 06.5.15 0:54 PM Page 61 8-2. ADJUSTING THE AMOUNT OF REFRIGERANT • Check additional refrigerant charging amount referring to table 5.6 when liquid pipe is one size larger than standard diameter. <Table 5> Required additional charge when the pipe size is larger than the standard diameter (1:1 SYSTEM) Liquid pipe dia Refrigerant amount to be added 35,50 [9.52 60 g per 1 m 60,71 [12.7 100 g per 1 m 100~140 [12.7 100 g per 1 m <Table 6> Required additional charge when the pipe size is larger than the standard diameter (TWIN/TRIPLE SYSTEM) Capacity When the extension pipe length (main piping + branch piping) exceed 20 m 71~140 Additional refrigerant amount W(g) = (100 o L1) + (60 o L2) + (30 o L3) - 2000 If the calculation produces a negative number ( W [ 0), additional charging is not necessary. L1: [12.7 liquid pipe length (m) L2: [9.52 liquid pipe length (m) L3: [6.35 liquid pipe length (m) <Table 7> Additional refrigerant charging amount for pipe of standard diameter Type Outdoor unit 1:1 PUHZ-RP35,50VHA2 system PUHZ-RP71VHA2 PUHZ-RP100~140 Type Outdoor unit Twin Triple PUHZ-RP71VHA2 system PUHZ-RP100~140 Permitted pipe length 50m or less Amount of unit filling refrigerant (kg) Additional refrigerant charging amount for pipe length exceeding 30 m (kg) 31 — 40m 41 — 50m 51 — 60m 61 — 70m 71 — 75m 2.5kg 0.2kg 0.4kg 3.5kg 0.6kg 1.2kg 75m or less 5.0kg 0.6kg 1.2kg Permitted pipe length Amount of unit filling refrigerant (kg) 50m or less 3.5kg 0.6kg 1.2kg 75m or less 5.0kg 0.6kg 1.2kg 61 1.8kg 2.4kg Additional refrigerant charging amount for pipe length exceeding 30 m (kg) — 31 40m 41 — 50m 51 — 60m 61 — 70m 71 — 75m 1.8kg 2.4kg OCS05A-3.qxp 06.5.15 0:54 PM Page 62 8-3. CAPACITY CORRECTION CURVES Cooling and heating capacity is lowered according to pipe length. Capacity can be obtained by referring to the capacity curves below. When the diameter of gas pipe is one size smaller than standard diameter, cooling capacity is lowered comparing to the standard diameter. The lowered capacity can be obtained by referring to capacity curves for gas pipe which is one size smaller than standard size. Corrected pipe length (m) = actual pipe length (m) + number of bends x 0.3 (m) [Sample calculation] Indoor unit RP60 o 2 units (Twin system) Outdoor unit RP125 o 1 ■ Condition Using existing pipes. • Outdoor unit side Liquid pipe [12.7 / Gas pipe [19.05 pipe length (A) 20m • Indoor unit side Liquid pipe [9.52 / Gas pipe [15.88 pipe length (B) 20m + (C) 15m 1) Farthest piping length 20m + 15m = 35m Number of bends : 10 2) Corrected piping length 35m + 0.3 o 10 = 38m 3) Capacity correction Outdoor unit side’s gas pipe [19.05 Standard [15.88 → 1 size up Refer to 1Capacity curves <Standard size> 4) Capacity Cooling capacity = Standard cooling capacity o 0.89 Heating capacity = Standard heating capacity o 0.98 1 Capacity curves for PUHZ-RP • HA2 model <Standard size> Cooling 100 Heating 95 Heating RP35, 50, 60, 71, 100, 125 and 140 models (Up to 55m for RP35, 50, 60, 71 models) Capacity ratio [%] Cooling RP35, 60 models Cooling RP71 model 90 85 Cooling RP50, 100 models 80 Cooling RP125 model 75 Cooling RP140 model Note: The permitted pipe length is up to 55m for RP35, 50, 60, 71 model. The permitted pipe length is up to 80m for RP100 ~ 140 model. 70 5 10 15 20 25 30 35 40 45 50 55 Corrected pipe length [m] 62 60 65 70 75 80 OCS05A-3.qxp 06.5.15 0:54 PM Page 63 2 Capacity curve for PUHZ-RP35, 50 models <When gas pipe is one size smaller than standard size> Cooling 100 Heating Heating RP35, RP50 ([9.52) Capacity ratio [%] 95 90 Cooling RP50 ([9.52) 85 Cooling RP35 ([9.52) 80 5 10 15 20 25 30 35 Corrected pipe length [m] 3 Capacity curve for PUHZ-RP60, 71 models <When gas pipe is one size smaller than standard size> 100 Heating RP60, RP71 ([12.7) Capacity ratio [%] 95 90 85 80 Cooling RP60,RP71 ([12.7) 5 10 15 20 25 30 35 Corrected pipe length [m] 4 When gas pipe is one size larger than standard size for PUHZ-RP100, 125 and 140. 1 Capacity can be obtained by referring to capacity curves of standard size. 63 OCS05A-3.qxp 9 06.5.15 0:54 PM Page 64 AIR FLOW DATA 9-1. OUTLET AIR SPEED AND COVERAGE RANGE Air flow Air speed Coverage range m3/min. m/sec. m PLA-RP35AA 14 2.8 4.0 Air flow Air speed Coverage range m3/min m/sec m Air flow Air speed Coverage range m3/min Air flow m3/min Air speed m/sec Coverage range m (ft) Air flow m3/min Air speed m/sec Coverage range m (ft) Air flow Air speed Coverage range m/sec m PLA-RP50AA 18 3.6 5.2 PLA-RP60AA 18 3.6 5.2 PLA-RP71AA 20 4.0 5.7 PLA-RP125AA2 30 6.6 8.9 PLA-RP140AA2 30 6.6 8.9 PCA-RP50GA PCA-RP60GA PCA-RP71GA PCA-RP100GA PCA-RP125GA PCA-RP140GA 34 34 18 13 25 18 4.4 4.4 3.8 3.7 4.1 3.8 15.2 15.2 10.4 8.8 12.6 10.4 PCA-RP71HA PCA-RP125HA 38 19 4.2 2.9 7.9 13.2 PKA-RP35GAL PKA-RP50GAL 12 12 5.3 5.3 10(32.8) 10(32.8) PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL 20 20 28 4.9 4.9 5.4 12.4(40.7) 12.4(40.7) 15.3(50.2) m3/min m/sec m PLA-RP100AA2 28 4.9 7.4 PSA-RP71GA 18 2.6 8.3 PSA-RP100GA 31 4.5 14.3 PSA-RP125GA 33 4.8 15.2 PSA-RP140GA 35 4.9 16.1 The air coverage range is the value up to the position where the air speed is 0.25m/sec. when air is blown out horizontally from the unit at the Hi notch position. The coverage range should be used only as a general guideline since it varies according to the size of the room and the furniture inside the room. 64 OCS05A-3.qxp 06.5.15 0:54 PM Page 65 9-2. PLA-RP·AA(2) 9-2-1. FRESH AIR INTAKE AMOUNT 65 OCS05A-3.qxp 06.5.15 0:54 PM Page 66 66 OCS05A-3.qxp 06.5.15 0:54 PM Page 67 9-2-2. BRANCH DUCT (Installation at site) 67 OCS05A-3.qxp 06.5.15 0:54 PM Page 68 Branch duct air flow rate/static pressure characteristics PLA-RP35AA 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct 2-way air flow (horizontal vane) Rectangular duct 2-way air flow (horizontal vane) Round duct 68 OCS05A-3.qxp 06.5.15 0:54 PM Page 69 PLA-RP50AA PLA-RP60AA 4-way air flow (horizontal vane) Rectangular duct 4-way air flow (horizontal vane) Round duct 3-way air flow (horizontal vane) Rectangular duct 3-way air flow (horizontal vane) Round duct 2-way air flow (horizontal vane) Rectangular duct 2-way air flow (horizontal vane) Round duct 69 OCS05A-3.qxp 06.5.15 0:54 PM Page 70 PLA-RP71AA 4-way air flow (horizontal vane) Round duct Static pressure [Pa] 30 20 High 10 Low 0 1 2 3 4 5 6 Static pressure [Pa] 4-way air flow (horizontal vane) Rectangular duct 30 20 High 10 Low 0 1 2 3 Air flow rate [m3/min] 3-way air flow (horizontal vane) Rectangular duct 6 60 50 Static pressure [Pa] Static pressure [Pa] 5 3-way air flow (horizontal vane) Round duct 60 40 High 30 20 Low 10 50 40 1 2 3 4 5 6 7 8 9 High 30 20 Low 10 0 0 1 2 3 4 Air flow rate [m /min] 2-way air flow (horizontal vane) Rectangular duct 5 6 7 2-way air flow (horizontal vane) Round duct 100 100 90 90 80 Static pressure [Pa] 80 70 60 High 50 40 Low 30 20 10 70 60 50 High 40 Low 30 20 10 0 1 2 3 4 5 6 7 8 9 10 8 Air flow rate [m3/min] 3 Static pressure [Pa] 4 Air flow rate [m3/min] 11 0 Air flow rate [m3/min] 1 2 3 4 5 6 Air flow rate [m3/min] 70 7 9 OCS05A-3.qxp 06.5.15 0:54 PM Page 71 PLA-RP100AA2 4-way air flow (horizontal vane) Round duct 50 Static pressure [Pa] Static pressure [Pa] 4-way air flow (horizontal vane) Rectangular duct 40 30 High 20 Low 10 0 1 2 3 4 5 6 7 8 9 50 40 30 High 20 Low 10 0 10 1 2 3 4 5 Air flow rate [m /min] 3 3-way air flow (horizontal vane) Rectangular duct 8 9 10 100 90 90 Static pressure [Pa] Static pressure [Pa] 7 3-way air flow (horizontal vane) Round duct 100 80 70 60 High 50 40 30 Low 20 10 80 70 60 50 High 40 30 Low 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 0 14 1 Air flow rate [m3/min] 110 100 100 90 90 Static pressure 120 110 80 High 60 50 Low 40 30 50 4 5 6 7 8 9 10 11 12 13 14 15 7 8 9 10 11 12 13 14 High 40 Low 30 10 3 6 60 10 2 5 70 20 1 4 80 20 0 3 2-way air flow (horizontal vane) Round duct 120 70 2 Air flow rate [m3/min] 2-way air flow (horizontal vane) Rectangular duct Static pressure [Pa] 6 Air flow rate [m3/min] 0 16 1 Air flow rate [m /min] 3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Air flow rate [m3/min] 71 16 OCS05A-3.qxp 06.5.15 0:54 PM Page 72 PLA-RP125AA2 PLA-RP140AA2 4-way air flow (horizontal vane) Round duct 50 50 40 30 High 20 Low 10 0 1 2 3 4 5 6 7 8 9 10 Static pressure [Pa] Static pressure [Pa] 4-way air flow (horizontal vane) Rectangular duct 40 30 High 20 10 Low 0 1 2 3 4 5 100 100 90 90 80 70 60 High 40 Low 20 10 0 9 10 80 70 60 50 High 40 30 Low 20 10 1 2 3 4 5 6 7 8 9 10 11 12 13 0 14 1 2 3 4 5 6 Air flow rate [m /min] 3 2-way air flow (horizontal vane) Rectangular duct 120 110 110 100 100 90 80 70 High 50 40 Low 30 8 9 10 11 12 13 14 2-way air flow (horizontal vane) Round duct 120 60 7 Air flow rate [m3/min] Static pressure[Pa] Static pressure [Pa] 8 3-way air flow (horizontal vane) Round duct Static pressure [Pa] Static pressure [Pa] 3-way air flow (horizontal vane) Rectangular duct 30 7 Air flow rate [m /min] Air flow rate [m /min] 50 6 3 3 20 10 90 80 70 60 50 High 40 Low 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 16 1 Air flow rate [m3/min] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Air flow rate [m3/min] 72 16 OCS05A-3.qxp 06.5.15 0:54 PM Page 73 9-2. PEAD-RP·EA, EA2, GA 9-2-1. FAN PERFORMANCE AND CORRECTED AIR FLOW PEAD-RP35EA2 PEAD-RP50EA Fan Performance <30Pa> Corrected Air Flow 120 100 Correction factor External static pressure (Pa) (1Pa 0.1mmAq) 140 80 60 40 20 Cooling 1.0 0.9 0.8 8 6 8 10 10 12 14 16 18 20 Air Flow (CMM) Fan Performance <70Pa> 160 12 14 16 18 Air flow (CMM) 20 22 12 14 16 18 Air flow (CMM) 20 22 Heating 1.3 140 Correction factor External static pressure (Pa) (1Pa 0.1mmAq) 1.1 Capacity input 120 100 80 60 40 1.2 1.1 1.0 0.9 0.8 8 10 20 8 10 12 14 16 18 20 22 Air Flow (CMM) Fan Performance <30Pa> 120 Correction factor 100 80 60 40 20 8 140 External static pressure (Pa) (1Pa 0.1mmAq) Corrected Air Flow 1.1 Capacity input Cooling 1.0 0.9 0.8 12 14 16 18 20 22 Air flow (CMM) 10 12 14 16 18 20 22 24 Air Flow (CMM) 24 26 Heating Fan Performance <70Pa> 1.3 Correction factor External static pressure (Pa) (1Pa 0.1mmAq) PEAD-RP60EA 120 100 80 60 40 1.2 1.1 1.0 0.9 0.8 12 14 16 18 20 22 24 Air flow (CMM) 20 10 12 14 16 18 20 22 24 26 Air Flow (CMM) 73 26 OCS05A-3.qxp 06.5.15 0:54 PM Page 74 PEAD-RP71EA Fan performance <70Pa> Fan performance <130Pa> Recommended range External static pressure (Pa) (1Pa = 0.1mmAq) Recommended range External static pressure (Pa) (1Pa = 0.1mmAq) 200 180 160 140 Hi Lo 120 100 80 60 40 20 180 160 140 120 Hi Lo 100 80 60 40 20 12 16 20 24 28 32 12 16 20 24 28 32 A i r fl ow (C MM) A i r fl o w (C M M ) Corrected Air Flow Capacity Input Cooling 1.1 1.2 Correction factor Correction factor Heating 1.3 1.0 0.9 0.8 12 16 20 24 28 1.1 1.0 0.9 32 Air flow (CMM) 0.8 12 16 20 24 28 32 Air flow (CMM) PEAD-RP100EA2 PEAD-RP125EA Fan performance <70Pa> Fan performance <130Pa> Recommended range 220 External static pressure (Pa) (1Pa = 0.1mmAq) External static pressure (Pa) (1Pa = 0.1mmAq) Recommended range 200 180 160 140 120 100 Hi 80 60 Lo 40 20 220 200 180 160 140 120 100 32 34 36 38 40 42 44 46 48 60 40 32 34 36 38 40 42 44 46 A i r fl ow (C MM) Heating Corrected Air Flow 1.2 Correction factor Capacity Input Cooling Correction factor 1.1 1.0 0.9 34 36 Lo 20 A i r fl o w (C M M ) 0.8 32 Hi 80 38 40 42 44 46 1.1 1.0 0.9 0.8 48 32 Air flow (CMM) 34 36 38 40 42 44 Air flow (CMM) 74 46 48 06.5.15 0:54 PM Page 75 PEAD-RP140EA Fan performance <70Pa> Recommended range External static pressure (Pa) 220 (1Pa = 0.1mmAq) External static pressure (Pa) Recommended range 200 180 160 140 120 100 80 60 40 Hi Lo 200 (1Pa = 0.1mmAq) Fan performance <130Pa> 180 160 140 120 100 80 Hi 60 Lo 40 20 20 36 38 40 42 44 46 48 50 52 36 38 40 42 44 46 48 50 A i r fl o w (C M M) A i r fl ow (C MM ) Heating Corrected Air Flow Correction factor 1.1 1.0 0.9 0.8 36 1.2 Capacity Input Cooling Correction factor OCS05A-3.qxp 38 40 42 44 46 48 50 52 1.1 1.0 0.9 0.8 36 38 40 42 44 46 Air flow (CMM) Air flow (CMM) 75 48 50 52 OCS05A-3.qxp 06.5.15 0:54 PM Page 76 PEAD-RP60GA PEAD-RP71GA 76 OCS05A-3.qxp 06.5.15 0:54 PM Page 77 PEAD-RP100GA 77 OCS05A-3.qxp 10 06.5.15 0:54 PM Page 78 NOISE CRITERION CURVES NOTCH SPL(dB) High 31 Medium1 29 Medium2 28 Low 27 PLA-RP35AA LINE PLA-RP50AA PLA-RP60AA 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 10 250 500 1000 2000 4000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 8000 63 125 250 BAND CENTER FREQUENCIES, Hz LINE 1000 2000 4000 NOTCH SPL(dB) High 41 Medium1 39 Medium2 36 Low 33 PLA-RP100AA2 90 8000 LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 125 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 10 63 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 500 BAND CENTER FREQUENCIES, Hz NOTCH SPL(dB) High 34 Medium1 32 Medium2 30 Low 28 PLA-RP71AA 20 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 20 NOTCH SPL(dB) High 33 Medium1 31 Medium2 29 Low 28 250 500 1000 2000 4000 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 BAND CENTER FREQUENCIES, Hz 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 78 4000 8000 OCS05A-3.qxp 06.5.15 0:54 PM Page 79 NOTCH SPL(dB) 45 High 43 Medium1 40 Medium2 37 Low PLA-RP125AA2 LINE PLA-RP140AA2 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NOTCH SPL(dB) 45 High 43 Medium1 40 Medium2 37 Low APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 63 125 250 BAND CENTER FREQUENCIES, Hz 500 1000 2000 BAND CENTER FREQUENCIES, Hz UNIT CEILING 1.5m MICROPHONE 79 4000 8000 Page 80 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa PEAD-RP35EA2 PEAD-RP50EA 70 PEAD-RP35EA2 PEAD-RP50EA (External static pressure 30Pa) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa 06.5.15 0:54 PM High Low 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 70 High Low NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 8000 63 (External static pressure 30Pa) High Low NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 250 500 PEAD-RP60EA 60 0 125 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa PEAD-RP60EA 70 (External static pressure 70Pa) 60 OCTAVE BAND CENTER FREQUENCIES (Hz) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa OCS05A-3.qxp 8000 70 High Low 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 OCTAVE BAND CENTER FREQUENCIES (Hz) (External static pressure 70Pa) 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) 80 8000 OCS05A-3.qxp 06.5.15 0:55 PM Page 81 81 OCS05A-3.qxp 06.5.15 0:55 PM PKA-RP35GAL PKA-RP50GAL Page 82 NOTCH SPL(dB) High 43 Medium1 41 38 Medium2 Low 36 LINE PKA-RP60FAL PKA-RP71FAL 90 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 OCTAVE BAND SOUND PRESSURE LEVEL, dB(0dB=0.0002 µ bar) 70 10 63 125 250 500 1000 2000 4000 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE 20 NC-20 10 8000 63 125 250 500 PKA-RP100FAL WALL 1m MICROPHONE 2000 4000 8000 NOTCH SPL(dB) High 46 Low 41 LINE 90 UNIT 1m 1000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz OCTAVE BAND SOUND PRESSURE LEVEL, dB(0dB=0.0002 µ bar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0dB=0.0002 µbar) LINE 90 80 20 NOTCH SPL(dB) High 45 Low 39 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 82 4000 8000 06.5.15 0:55 PM Page 83 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) PCA-RP50GA NOTCH SPL(dB) 42 High 40 Medium1 38 Medium2 37 Low PCA-RP60GA PCA-RP71GA LINE 90 90 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCS05A-3.qxp NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 NC-20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 250 500 1000 2000 4000 63 8000 125 PCA-RP100GA NOTCH SPL(dB) High 45 Medium1 43 Medium2 41 Low 40 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 500 1000 2000 2000 4000 8000 4000 NOTCH SPL(dB) High 46 Medium1 45 Medium2 43 Low 41 LINE NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 250 1000 70 NC-20 10 125 500 PCA-RP125GA LINE 90 63 250 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) NC-20 10 10 20 LINE 70 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NOTCH SPL(dB) High 43 Medium1 41 Medium2 39 Low 37 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 8000 63 BAND CENTER FREQUENCIES, Hz 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 83 4000 8000 OCS05A-3.qxp 06.5.15 0:55 PM PCA-RP140GA Page 84 NOTCH SPL(dB) High 48 Medium1 46 Medium2 44 Low 42 LINE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 80 ceiling 1m 70 NC-70 1m unit about 1.4m 60 NC-60 MICROPHONE 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz NOTCH SPL(dB) High 38 Low 34 LINE PCA-RP125HA 90 90 80 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR PCA-RP71HA 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 LINE 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NOTCH SPL(dB) High 50 Low 44 NC-20 APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE NC-20 10 10 63 125 250 500 1000 2000 4000 63 8000 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz 84 4000 8000 06.5.15 0:55 PM Page 85 OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR PSA-RP71GA NOTCH SPL(dB) 45 High 40 Low PSA-RP100GA LINE 90 90 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE HERESHOLD OF REARING FOR CONTINUOUS NOISE LINE NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE HERESHOLD OF REARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 63 BAND CENTER FREQUENCIES, Hz PSA-RP125GA NOTCH SPL(dB) High 51 Low 46 LINE 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE HERESHOLD OF REARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR NOTCH SPL(dB) High 49 Low 44 70 NC-20 10 20 OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR OCS05A-3.qxp 4000 8000 BAND CENTER FREQUENCIES, Hz 85 4000 8000 OCS05A-3.qxp 06.5.15 0:55 PM PSA-RP140GA Page 86 NOTCH SPL(dB) High 52 Low 47 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE HERESHOLD OF REARING FOR CONTINUOUS NOISE NC-20 10 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz MICROPHONE 1m 1m unit floor 86 OCS05A-3.qxp 06.5.15 0:55 PM Page 87 MICROPHONE 1m UNIT 1.5m GROUND PUHZ-RP35VHA2 PUHZ-RP50VHA2 MODE SPL(dB) COOLING 44 HEATING 46 PUHZ-RP60VHA2 PUHZ-RP71VHA2 LINE 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 BAND CENTER FREQUENCIES, Hz PUHZ-RP100VHA2 PUHZ-RP100YHA2 MODE SPL(dB) COOLING 49 HEATING 51 500 1000 2000 4000 8000 MODE SPL(dB) COOLING 50 HEATING 52 LINE 90 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 250 PUHZ-RP125VHA2 PUHZ-RP140VHA2 PUHZ-RP125YHA2 PUHZ-RP140YHA2 LINE 80 10 125 NC-20 BAND CENTER FREQUENCIES, Hz 90 20 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 90 MODE SPL(dB) COOLING 47 HEATING 48 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 BAND CENTER FREQUENCIES, Hz 87 8000 OCS05A-3.qxp 11 06.5.15 0:55 PM Page 88 OPTIONAL PARTS 11-1. INDOOR UNIT Part Name Model Name Remote sensor Remote operation adapter Multiple remote controller adapter PAC-SE41TS-E PAC-SF40RM-E Remote on/off adapter Power supply terminal kit L/N/Earth L/N Multi-functional casement High-efficiency filter element (PAC-SG03TM-E is needed.) Grille + Wireless remote controller Grille + Wired remote controller Space panel Air outlet shutter plate (20 set, 2pcs/set) Wireless remote controller + Wireless Adapter Drain lift up mechanism High-efficiency filter Duct flange for fresh air Oil mist filter element (12pcs) Decoration cover (Front + Suspending bracket cover) Wired remote controller (with terminal bed) Drain lift up mechanism Motor (for high external static pressure) Drain lift up mechanism Insulation kit Applicable model PAC-SA88HA-E (1pc.) All models PAC-725AD (10pcs.) PAC-SE55RA-E PAC-SG96HR-E All models except PCA-RP·HA and PEAD-RP·GA PAC-SG97HR-E PCA-RP·HA PEAD-RP·GA PAC-SG03TM-E PAC-SG01KF PLP-6AALM PLP-6AAMD PAC-SG04AS-E PAC-SG06SP-E PLA-RP·AA PLA-RP·AA2 PAR-SL99B-E PAC-SH20DM-E PAC-SH21DM-E PAC-SH22DM-E PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E PAC-SF28OF-E PAC-SG38KF-E PAC-SF81KC-E PAC-SF82KC-E PAR-21MAAT-E PCA-RP·GA PCA-RP50,60GA PCA-RP71GA PCA-RP100,125,140GA PCA-RP50GA PCA-RP60,71,100GA PCA-RP125,140GA PCA-RP·HA PAC-SE90DM-E PAC-SK003MT-F PAC-KE03DM-F PAC-SK010DK 88 PCA-RP71HA PCA-RP125HA PKA-RP·GAL PKA-RP·FAL PKA-RP·FAL PEAD-RP125,140EA PEAD-RP100EA2 PEAD-RP·EA,EA2 PEAD-RP·GA OCS05A-3.qxp 06.5.15 0:55 PM Page 89 11-2. OUTDOOR UNIT Part Name Model Name Applicable model M-NET adapter PAC-SF80MA-E All models A-control service tool PAC-SK52ST Drain socket PAC-SG61DS-E PUHZ-RP35-140 Air outlet guide PAC-SG58SG-E PUHZ-RP35, 50 (RP100,125,140 needs two piece.) PAC-SG59SG-E PUHZ-RP60-140 Air protect guide PAC-SG56AG-E PUHZ-RP35, 50 PAC-SH63AG-E PUHZ-RP60-140 PAC-SG63DP-E PUHZ-RP35, 50 PAC-SG64DP-E PUHZ-RP60-140 Drain pan Filter dryer ( [6.35) PAC-SG81DR-E PUHZ-RP35, 50 Distribution pipe ( [9.52) (Twin) PAC-SG82DR-E MSDD-50SR-E PUHZ-RP60-140 PUHZ-RP100-140 (Triple) MSDT-111R-E PUHZ-RP140 Joint pipe (Unit Extension pipe) ( [6.35 [9.52) PAC-SG72RJ-E PUHZ-RP35, 50 ( [9.52 [12.7) PAC-SG73RJ-E PUHZ-RP35, 50 PAC-SG75RJ-E PUHZ-RP60-140 ( [15.88 [19.05) 89 OCS05A-3.qxp 06.5.15 0:55 PM Page 90 TM HEAD OFFICE : TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN CCopyright 2006 MITSUBISHI ELECTRIC ENGINEERING CO., LTD. Distributed in May 2006 No.OCS05 REVISED EDITION-A PDF 8 Distributed in Feb. 2006 No.OCS05 PDF 8 Made in Japan. New publication, effective May 2006. Specifications subject to change without notice.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement