Crestron MMK-12L manual

Add to my manuals

advertisement

Crestron MMK-12L manual | Manualzz
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
Installation Guide
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
Contents
Mud Mount Kits: MMK-12L & WMKM-12L
1
Description................................................................................................................................. 1
Setup .......................................................................................................................................... 2
Supplied Hardware ...................................................................................................... 2
Installation ................................................................................................................... 4
Resources................................................................................................................................. 12
Industry Compliance ................................................................................................. 12
Reference Documents................................................................................................ 12
Further Inquiries ........................................................................................................ 12
Future Updates .......................................................................................................... 12
Return and Warranty Policies .................................................................................................. 13
Merchandise Returns / Repair Service ...................................................................... 13
CRESTRON Limited Warranty................................................................................. 13
All brand names, product names and trademarks are the property of their respective owners.
©2009 Crestron Electronics, Inc.
Installation Guide – DOC. 6359A
Contents • i
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
Mud Mount Kits:
MMK-12L & WMKM-12L
Description
Mud Mount Kits are the preferred mounting options for the Crestron Isys® TPS-12L,
TPS-12G-QM-L wall mount touchpanels, and the Isys i/O TPMC-12L wall mount
touchpanel media center when the cutout made in the drywall for touchpanel
installation is too large. These kits provide support for additional plastering that can
be applied to hide large irregularities in the touchpanel cutout.
NOTE: If mounting into a material other than drywall (for example, wood lectern,
concrete or rock) use the cutout template, available in the post-construction kit
WMKM-12L. For concrete and rock mounting material, allow for proper ventilation
before mounting the touchpanel.
There are two Mud Mount Kits. The MMK-12L is a pre-construction accessory. Preconstruction refers to framed walls prior to hanging drywall. This accessory must be
used with either the Pre-Construction Mount Kit (PMK-12L) or Wall Mount Back
Box Kit (BB-12L).
The WMKM-12L is a post-construction kit. Post-construction refers to framed walls
with drywall hung. This accessory is designed with a mounting plate so that it can be
placed anywhere on a wall without the support of a stud.
NOTE: If necessary, consult the latest revision of the TPS-12L/15L/17L Operations
Guide (Doc. 6355), TPS-12G/15G/17G-QM-L Operations Guide (Doc. 6356), and
TPMC-12L Operations Guide (Doc. 6686) for a complete list of mounting options.
These documents are available from the Crestron website
(www.crestron.com/manuals).
Installation Guide – DOC. 6359A
Mud Mount Kits: MMK-12L & WMKM-12L • 1
Mud Mount Kits
Crestron MMK-12L & WMKM-12L
Setup
Supplied Hardware
The MMK-12L consists of three parts. These parts produce an assembly that attaches
to the BB-12L or PMK-12L. The WMKM-12L consists of five parts, three of which
make up the MMK-12L, as well as a mounting plate and a cutout template set.
The mounting plate provides the necessary support for post-construction
applications. Two overlay cutout templates (4007385) are supplied. One is in the
shape of the required opening; the other is similar to a frame, with the inner area of
the frame the shape of the required opening. Separate the wall cutout templates along
the perforated lines to create the two templates. (Refer to the illustration on pages 3
and 4.) Use the template that is most convenient.
Supplied Hardware for the MMK-12L and WMKM-12L
DESCRIPTION
Metal, Plate, Mud Ring
PART NUMBER
QUANTITY
2013002
1
Metal Plate, Adjustment
2004825
2
Hardware, Metal, Push-On Fasteners
2004121
4
Metal, Plate, Mounting
(WMKM-12L only)
2012963
1
Overlay, Template, Wall Cutout
(WMKM-12L only)
4007385
1
The dimensions of the MMK-12L and WMKM-12L are shown below and on the
next page.
Dimensional Drawing – Mud Ring Plate
12.33 in
(31.31 cm)
2.26 in
(5.73 cm)
14.24 in
(36.16 cm)
2 • Mud Mount Kits: MMK-12L & WMKM-12L
Installation Guide – DOC. 6359A
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
Dimensional Drawing – Adjustment Plate
0.38 in
(0.95 cm)
0.38 in
(0.95 cm)
5.90 in
(14.99 cm)
Dimensional Drawing – Mounting Plate
13.63 in
(34.61 cm)
0.06 in
(0.15 cm)
11.99 in
(30.45 cm)
Drywall Cutout Template and Dimensions (supplied with WMKM-12L only), 1 of 2
2 5/16 in
(58 mm)
1/8 in
(3 mm)
12 7/8 in
(327 mm)
10 3/4 in
(274 mm)
6 1/4 in
(158 mm)
11 1/4 in
(286 mm)
11.00 in
(279 mm)
1 1/16 in
(27 mm)
Installation Guide – DOC. 6359A
.188 TYP
Mud Mount Kits: MMK-12L & WMKM-12L • 3
Mud Mount Kits
Crestron MMK-12L & WMKM-12L
Drywall Cutout Template and Dimensions (supplied with WMKM-12L only), 2 of 2
2 5/16 in
(58 mm)
1/8 in
(3 mm)
13 5/8 in
(346 mm)
12 7/8 in
(327 mm)
10 3/4 in
(274 mm)
6 1/4 in
(158 mm)
12.00 in
(305 mm)
11 1/4 in
(286 mm)
11.00 in
(279 mm)
.188 TYP
1 1/16 in
(27 mm)
Installation
This section provides an installation procedure for each Mud Mount Kit. The
“MMK-12L Procedure” starts below and the “WMKM-12L Procedure” starts on
page 7. Be sure to review each procedure before starting.
MMK-12L Procedure
This section provides the necessary steps for the assembly of the MMK-12L with
either the BB-12L or PMK-12L. It is assumed that the BB-12L or PMK-12L has
been secured to the stud according to the instructions in the latest revisions of their
Installation Guides (Doc. 6357 and Doc. 6358 respectively). It is also assumed that
drywall is in place and a cutout is made in the drywall along the inside of the
mounting plate for touchpanel installation.
Complete the steps in the order provided. The only tools or materials required and
not supplied are four standard drywall screws, #2 Phillips screwdriver, a level and
tools/material to apply drywall joint compound.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity
above and below the touchpanel for heat dissipation.
NOTE: The illustrations in this procedure show the installation of the MMK-12L
with the PMK-12L. Even though the illustrations only show the PMK-12L, the
procedure is identical for the BB-12L.
4 • Mud Mount Kits: MMK-12L & WMKM-12L
Installation Guide – DOC. 6359A
Crestron MMK-12L & WMKM-12L
1.
Mud Mount Kits
Pass an adjustment plate through the opening and align its two center holes
with the top two pins on the PMK-12L (or BB-12L). Verify that the pins on
the adjustment plate are not between (facing) the adjustment plate and the
PMK-12L (or BB-12L). Refer to the illustration below for visual guidance.
Secure Adjustment Plates to PMK-12L (or BB-12L)
2.
Slide a push-on fastener over each pin of the PMK-12L (or BB-12L) to
loosely secure the adjustment plate and the mounting plate. Do not push the
push-on fasteners all the way down onto the pins. Slide them on enough to
keep the adjustment plate and mounting plate as one adjustment/mounting
plate assembly.
3.
Use the second adjustment plate and repeat steps 1 and 2 using the lower
two PMK-12L (or BB-12L) pins.
NOTE: When installing into the PMK-12L, verify that the 18 AWG bus wire
securing the cables for the touchpanel remains attached.
4.
Installation Guide – DOC. 6359A
Insert the symmetrical mud ring plate into the opening, as shown in the
illustration on the following page.
Mud Mount Kits: MMK-12L & WMKM-12L • 5
Mud Mount Kits
Crestron MMK-12L & WMKM-12L
Insert and Secure Mud Ring Plate into PMK-12L (or BB-12L)
5.
When the mud ring plate is in position, bend the top two flanges of the plate
upward and the bottom two flanges downward.
•
If mounting into the PMK-12L, bend the flanges approximately
90 degrees.
•
If mounting into the BB-12L, bend the flanges back as far as they can
go.
6.
Use four standard drywall screws (length should not exceed drywall
thickness by more than 1/2 inch) to secure the mud ring plate to the rest of
the assembly. The screws pass through the clearance holes in the PMK-12L
(or BB-12L) and are secured in the extruded holes of the adjustment plates.
7.
Verify that the mud ring plate is level.
NOTE: Do not over tighten screws. Doing so may over-dimple or rip the mud ring
plate.
8.
Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that
they slightly dimple into the holes in the mud ring plate.
9.
Apply drywall joint compound as needed to finish the cutout. Avoid
covering the eight tapped mounting holes.
10. Run the necessary cables for the touchpanel and secure them behind the
drywall.
11. When dry, the touchpanel can be installed using the eight tapped holes in
the PMK-12L (or BB-12L). Refer to the latest revision of the
6 • Mud Mount Kits: MMK-12L & WMKM-12L
Installation Guide – DOC. 6359A
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
TPS-12L/15L/17L Operations Guide (Doc. 6355),
TPS-12G/15G/17G-QM-L Operations Guide (Doc. 6356), or TPMC-12L
Operations Guide (Doc. 6686) for installation instructions. Refer also to the
comprehensive illustration seen below.
TPS-12L Mounting Using MMK-12L – Exploded View
PUSH-ON FASTENER (4)
(2004121)
ADJUSTMENT PLATE (2)
(2004825)
PMK-12L
MUD RING PLATE
(2013005)
TPS-12L
TOUCHPANEL
(Bezel Removed)
DRYWALL
MOUNTING SCREW (8)
#06-32 X 1-1/2”
(2007254)
(Bezel)
NOTE: MOUNTING SCREWS
SUPPLIED WITH TOUCHPANEL.
WMKM-12L Procedure
This section provides the necessary steps for the assembly and installation of the
WMKM-12L into a wall. Review the procedure and complete the steps in the order
provided. The only tools or materials required and not supplied are a drywall saw or
equivalent, a level, four standard drywall screws, #2 Phillips screwdriver and
tools/material to apply drywall joint compound.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity
above and below the touchpanel for heat dissipation.
1.
Installation Guide – DOC. 6359A
Insert the two pins on one adjustment plate into the top two outer holes on
the mounting plate, as shown in the illustration on the following page.
Mud Mount Kits: MMK-12L & WMKM-12L • 7
Mud Mount Kits
Crestron MMK-12L & WMKM-12L
Create the Adjustment/Mounting Plate Assembly
2.
Slide a push-on fastener over each pin on the adjustment plate to loosely
secure the adjustment plate and the mounting plate. Do not push the
push-on fasteners all the way down onto the pins. Slide them on enough to
keep the adjustment plate and mounting plate as one adjustment/mounting
plate assembly.
3.
Use the second adjustment plate and repeat steps 1 and 2 using the lower
two holes of the mounting plate.
4.
Locate an area on the wall that is free of miscellaneous wiring and studs.
5.
Make a small hole near the middle of the designated site; verify that the
location is suitable.
NOTE: Make the cutout as clean and level as possible. The mounting plate allows
for only minor leveling adjustments.
6.
Use the drywall saw or equivalent and the provided drywall cutout template
to produce an accurate and level cutout in the drywall.
7.
Insert the symmetrical mud ring plate into the opening, as shown in the
illustration on the following page.
8 • Mud Mount Kits: MMK-12L & WMKM-12L
Installation Guide – DOC. 6359A
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
Insert Mud Ring Plate into Opening
8.
Carefully pass the adjustment/mounting plate assembly through the opening
and rest the assembly against the interior surface of the drywall. Verify that
the adjustment plates are between the mounting plate and the drywall.
9.
When the adjustment/mounting plate assembly is in position, bend the top
two flanges of the mud ring upward (approximately 90 degrees) and the
bottom two flanges downward (approximately 90 degrees). Refer to the
illustration on the following page.
NOTE: Adjustment/mounting plate assembly will have slight play; this is normal. It
allows for minor adjustments to the entire assembly during installation.
Installation Guide – DOC. 6359A
Mud Mount Kits: MMK-12L & WMKM-12L • 9
Mud Mount Kits
Crestron MMK-12L & WMKM-12L
Bend Flanges
10. Use four standard drywall screws (length should not exceed drywall
thickness by more than 1/2 inch) to secure the plate to the
adjustment/mounting plate assembly. The screws pass through the clearance
holes in the mud ring plate and are secured in the extruded holes of the
adjustment plates.
11. Verify that the plate is level before tightening.
NOTE: Do not over tighten screws. Doing so may damage the plate.
12. Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that
they slightly dimple into the holes in the mud ring plate.
13. Run the necessary cables for the touchpanel and secure them behind the
drywall.
14. Apply drywall joint compound as needed to finish the cutout. Avoid
covering the eight tapped mounting holes.
10 • Mud Mount Kits: MMK-12L & WMKM-12L
Installation Guide – DOC. 6359A
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
15. When the joint compound is dry, the touchpanel can be installed using the
eight tapped holes in the mounting plate. Refer to the latest revision of the
TPS-12L/15L/17L Operations Guide (Doc. 6355),
TPS-12G/15G/17G-QM-L Operations Guide (Doc. 6356), or TPMC-12L
Operations Guide (Doc. 6686) for installation instructions. Refer also to the
comprehensive illustration below.
TPS-12L Mounting Using WMKM-12L – Exploded View
PUSH-ON FASTENER (4)
(2004121)
ADJUSTMENT PLATE (2)
(2004825)
MOUNTING PLATE
(2012963)
DRYWALL
MUD RING PLATE
(2013005)
TPS-12L TOUCHPANEL
(Bezel Removed)
(Bezel)
Installation Guide – DOC. 6359A
MOUNTING SCREW (8)
#06-32 X 1-1/2”
(2007254)
NOTE: MOUNTING
SCREWS SUPPLIED
WITH TOUCHPANEL
Mud Mount Kits: MMK-12L & WMKM-12L • 11
Mud Mount Kits
Crestron MMK-12L & WMKM-12L
Resources
Industry Compliance
As of the date of manufacture, the MMK-12L and WMKM-12L have been tested
and found to comply with specifications for CE marking.
Reference Documents
The latest version of all documents mentioned within the guide can be obtained from
the Crestron website (www.crestron.com/manuals). This link will provide a list of
product manuals arranged in alphabetical order by model number.
List of Related Reference Documents
DOCUMENT TITLE
BB-12L Wall Mount Back Box
PMK-12L Pre-Construction Mounting Kit
TPMC-12L Isys i/O™ Wall Mount Touchpanel Media Center
TPS-12G/15G/17G-QM-L Isys® G-Series Wall Mount Touchpanels
TPS-12L/15L/17L Isys® Wall Mount Touchpanels
Further Inquiries
If you cannot locate specific information or have questions after reviewing this
guide, please take advantage of Crestron's award winning customer service team by
calling Crestron at 1-888-CRESTRON [1-888-273-7876].
You can also log onto the online help section of the Crestron website
(www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time
users will need to establish a user account to fully benefit from all available features.
Future Updates
As Crestron improves functions, adds new features and extends the capabilities of
the MMK-12L or WMKM-12L, additional information may be made available as
manual updates. These updates are solely electronic and serve as intermediary
supplements prior to the release of a complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its
relevance. Updates are identified as an “Addendum” in the Download column.
12 • Mud Mount Kits: MMK-12L & WMKM-12L
Installation Guide – DOC. 6359A
Crestron MMK-12L & WMKM-12L
Mud Mount Kits
Return and Warranty Policies
Merchandise Returns / Repair Service
1.
No merchandise may be returned for credit, exchange or service without prior authorization
from CRESTRON. To obtain warranty service for CRESTRON products, contact an
authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying
the nature of the problem, name and phone number of contact person, RMA number and
return address.
2.
Products may be returned for credit, exchange or service with a CRESTRON Return
Merchandise Authorization (RMA) number. Authorized returns must be shipped freight
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its
sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any
products returned with an RMA.
3.
Return freight charges following repair of items under warranty shall be paid by CRESTRON,
shipping by standard ground carrier. In the event repairs are found to be non-warranty, return
freight costs shall be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials
and workmanship under normal use for a period of three (3) years from the date of purchase from
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical
parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and
overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if
any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any
application other than that for which it was intended or if it has been subjected to misuse, accidental
damage, modification or improper installation procedures. Furthermore, this warranty does not cover any
product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages
inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a
third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the
unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or
implied, nor authorizes any other party to offer any warranty, including any implied warranties of
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are
limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark
of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation.
Installation Guide – DOC. 6359A
Mud Mount Kits: MMK-12L & WMKM-12L • 13
Crestron Electronics, Inc.
15 Volvo Drive Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
Installation Guide – DOC. 6359A
(2013442)
03.09
Specifications subject to
change without notice.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement