IDH MAX

®

&

ELECTROMECHANICAL LOCKS

2

TABLE OF CONTENTS

IDH MAX ®

Page introduction ....................................................2

IDH MAX ®

IDH Max ® features ..........................................................2

and IDH Max ® 1300 comparison chart ............3

HM, KM, HW & KW options ............................................3

40HM IDH MAX ® specifications, how-to-order ................4

40HM IDH MAX ®

93KM IDH MAX ® functions ..............................................5

specifications........................................6

93KM IDH MAX ®

93KM IDH MAX ® how-to-order ........................................6

functions ..............................................7

40HW electrified specification ..........................................7

40HW electrified how-to-order ........................................8

Page

40HW electrified functions ..............................................8-9

8KW/9KW electrified specification ....................................10

8KW/9KW electrified how-to-order ..................................10

8KW/9KW electrified functions ........................................10

Trim variations ..................................................................11

Electrified accessories ................................................12,13

Terminology ......................................................................13

1W electric switch lock introduction ..................................14

Optional boxes ..................................................................14

1W electric switch lock how-to-order ................................14

1W electric switch locks................................................15-19

IDH MAX ® – INTRODUCTION

The IIDH MAX ® from Stanley Security Solutions offers convenience and efficiency for your electrified lock applications. Instead of installing reader devices, installing electrified strikes, installing door contacts and installing request-to-exit devices, you can now install the IDH MAX ® in cylindrical or mortise lock applications. With IDH MAX ® all of the formerly separate equipment needed to control access are self-contained in a single installation. The complexity of multiple wire runs is drastically reduced.

You can let Stanley Security Solutions show you how to MAXimize your access control system with the IDH MAX ® ! For the name and location of your local office, visit our web site at www.stanleysecuritysolutions.com. IDH MAX ® and W series locks (with the exception of the IDH Max ® 1300) are compatible with Stanley’s NT500 and B.A.S.I.S. Acess Control Systems.

IDH MAX ® – FEATURES

IDH Max

®

Features

• Includes latch and door position indicator, RQE switch.

• The 1300 option eliminates the need for a RIM (reader interface module) which is embedded behind the escutcheon

• Requires only one 4 conductor wire run

• Reduces number of components installed and visible at the door (PIR, RQE push buttons and door contacts)

• Installation time is reduced

• The RQE switch senses the inside lever/knob rotation.

• All of the door components are housed in one manufacturer's hardware

• With the elimination of components, only the lockset is visible at the door

• The reader is integrated into the lockset escutcheon

• Available in magnetic stripe and proximity readers

• Available in all popular lever/knob styles and finishes

• Operates with BEST interchangeable core as a mechanical override

• Integrates with many manufacturer's on-line EAC equipment

Mortise Features

(continued)

• Twist off lever spindle design protect internal lock parts from damage and failure.

• Oil impregnated stainless steel 3 /

4

" anti-friction latchbolt reduces door closing force and wear.

Cylindrical Features

• Non-handed levers allow for ease of installation

• Lock chassis meets the requirements as listed in the ANSI/

BHMA A156.2, standard for Series 4000 Grade 1 locks

• UL listed for GYQS Electrically controlled single point licks or latches for use on 3 hr, A label single doors (4 ' x 10 ' ) GYJB.

The listing applies for both U.S. and Canadian applications

• Request-to-exit sensor positioned inside lock trim

• The ISC (Intelligent System Controller) is embedded behind the escutcheon secured and out of site

• Request-to-exit and door contact sensors are standard in

IDH MAX cylindrical locks

Mortise Features

• Lock case meets the requirements as listed in the ANSI/

BHMA A156.13 standard for Series 1000, Grade 1

Operational and Grade 2 Security locks

• UL listed for GYQS Electrically controlled single point locks or latches for use on 3 hr, A label doors (4 ' x 10 ' ). The listing applies for bother U.S. and Canadian applications

• Door contact, request-to-exit, and latch status sensors positioned inside lock case

• The 1300 option eliminates the need for a RIM (reader interface module) which is embedded behind the escutcheon

• The door contact magnet is installed behind the strike and out of site (except when deadbolt option is ordered)

• All sensors are all standard in IDH Max mortise locks

• The heavy duty design of the mortise lock makes easy field maintenance and reduces risk of part failure

Magnetic Stripe Electronic Lock Features

• Durable material has teflon-like characteristics for increased life and wear resistance

• Variable read rate allows for easy usage

Proximity Card Reader Features

• HID and Motorola/Indala proximity cards supported

• UL listed for GYQS Electrically controlled single point locks or latches.

• Usable in all environmental/exterior applications.

1300 Option Features

• Eliminates need for small panel interface module

• Eliminates reader interface board

• Incorporates 3 modules into a single electronics board inside

IDH Max escutcheon trim

• Connects directly to ACP via 2 wire RS485 connection

I D H M A X ® & E L E C T R O

IDH MAX ®

*

& IDH MAX ® 1300 COMPARISON CHART

**

IDH MAX ®

1. Prep door for IDH MAX ®

2. Run single 4 conductor wire for IDH MAX ®

3. Install IDH MAX ®

4. Install electrified hinge

5. Mount control panel

* Operates with any control panel hardware, including B.A.S.I.S.

control panels.

IDH MAX ® 1300

1. Prep door for IDH MAX ®

2. Run single 4 conductor wire for IDH MAX ®

3. Install IDH MAX ®

1300

1300 which includes Intelligent System

4. Install electrified hinge

** Operates with B.A.S.I.S. control panels only.

HM, KM, HW & KW – OPTIONS

AL– Besides complying with a wide variety of accessibility codes and ordinances, lever handles are available with a special abrasive feature. Abrasive strip on the lever immediately identifies warnings on doors to hazardous areas for the blind.

BRK– When excessive force (approx. 300 inch lbs.) is applied to #4, #6 keyed knobs, they “breakaway” and spin freely, thus allowing entrance only by key. Simple part replacement returns lock to functional usage.

IDH– The integrated Door Hardware groups three components into one hardware package. 1. Door monitoring switch (normally closed) 2. Request-to-Exit switch (normally open) 3. Electrically controlled locking mechanism.

KNL– Knurl feature is available only on #6 knobs. The knurling is machined into the outer edge of the knob. The knurled feature can be used for blind, safety, or accessibility applications.

LL– Lead lined feature can be used to protect against X-rays. Since the majority of lead lined doors contain the lead in the surface of the door, the knob lockset provide lead lining for the holes cut in the door when preparing the door for the trim.

LM– The Lost Motion feature allows the lever handle to move 45 degrees from parallel to the horizontal plane without engaging the latchbolt assembly. When the lockset is in the locked mode, this feature makes over-torque or over-lever-age abuse more difficult to achieve.

SH– Security head provided for all exposed screws.

RQE– Cylindrical or Mortise locksets can be supplied with a request-to-exit switch. A normally open switch provides momentary switch closure when the inside lever/knob is rotated.

TAC– Grooves are machined into knobs to improve grip or to be used as a warning in hazardous areas. This option can be used for blind, safety or accessibility applications.

Thick door– Specify thickness if other than 1 3 ⁄

4

" .

TL– Tactile levers may be used in areas where improved grip is required or as a warning in hazardous or Safety First areas. Grooves are machined into the back of the hand grasp portion of the lever to improve grip and/or provide a sensory warning. This option can be used for blind, safety, or accessibility applications.

1300– Integrated BAS1300/LNL1300 reader electronics board or (ISC) Intelligent System Controller is embedded behind the escutcheon secured and out of site. Functions with B.A.S.I.S./Mercury on-line equipment only.

OMECHANICAL LOCKS

3

4

40HM IDH MAX ® – SPECIFICATIONS

MECHANICAL

Case— Heavy wrought steel, 5 7 ⁄

8

" H x 4 1 ⁄

4

" D x 1 " W steel parts are zinc dichromate plated for corrosion protection.

Faceplate— Brass or bronze, 1 to beveled 1 ⁄

8

" - 2 " .

1 ⁄

4

" x 8 " x 7 ⁄

32

" . Armored. Adjustable from flat

Strike— Brass, bronze or Stainless Steel, 4 7 ⁄

8

" x 1 1 ⁄

4

" x 3 ⁄

32

" . Fits standard door frame cut out as specified in ANSI A115.1.Correct strike automatically supplied with unit. Strike box supplied standard.

Door thickness— For doors 1 3 ⁄

4

" – 4 " thick.

Installation— Lock requires modified door prep to mount the trim. Faceplate dimensions fit standard door preparation as specified in ANSI A115.1,.

Lockset is reversible for hand of door.

Latchbolt— Stainless steel, 3 ⁄

4

" throw with anti-friction latch.

Deadbolt— Solid stainless steel, 1 " throw.

Auxiliary bolt— Stainless steel.

Die cast trim housing—Dimensions: 10

Knobs— Diameter: 2 1

3 ⁄

8

" H x 3 1 ⁄

4

" W x 1 " D sloping down to 3 ⁄

4

" .

8

" Projection on door: 2 7 ⁄

8

"

#4, #6 knobs: Material machined from brass or bronze.

Lever handle— Brass, bronze or stainless steel. (Lever #3, #14 and #15 conform to California Titles 19 and 24.)

Mounting— Knob and lever attached with hardened set screw on inside knob or inside lever.

45HM IDH MAX ® Mortise

Finish— 605-bright brass, clear coated; 606-satin brass, clear coated; 611-bright bronze, clear coated; 612-satin bronze, clear coated; 613-oxidized satin bronze, oil rubbed; 625-bright chromium plated; 626-satin chromium plated; 629-bright stainless steel; 630-satin stainless steel; 690-dark bronze.

ELECTRONIC

Maximum current draw: 1.1 Amp for 50 milliseconds

Typical current draw (hold condition): 650 milliAmps

Voltage: 10.2 to 13.2 V (DC only)

Operating Temperature: Minimum/Maximum range Inside: 70˚± 4˚F (21˚± 2˚C) Outside: -31˚F (-35˚C) to +151˚F (+66˚C)

Magnetic Stripe Card Reader:

Read Rate: 5 inches per second to 50 inches per second.

Card thickness: ISO standard .030

"

± .003 thick.

Compliance to FCC, Canadian, and European EMC requirements; for interference FCC Class A digital apparatus.

Magnetic Stripe adaptation: Trim option that can accept other manufacturers cylinder.

Proximity Reader:

ANSI/BHMA A156.25 compliant. Compatible with Motorola / Indala and HID proximity cards. ABA and Wiegand output.

Weatherproof bezel and gasket provide protection for outdoor use. (Usable in all environmental/exterior applications)

Card Read Range: 0 – 3 inches. Compliance to US FCC, Canadian FCC, and European EMC requirements

ESD Protection:15 Kilo Volt

40HM IDH MAX ®

HOW TO ORDER

45HM

Series

7

Core

Housing

DEU

Function

14

Lever/Knob

Style

MS

Trim

Style

626

Finishes

45HM–

IDH Max™

0– Keyless or less cylinder,

7– 7 pin housing

ONLY

DEL– electrically locked

DEU– electrically unlocked

NXEL– electrically locked

NEU– electrically unlocked

TDEL– electrically locked

TDEU– electrically unlocked

LEL– electrically locked

LEU– electrically unlocked

(page 5)

Levers

3– solid tube return

12– solid tube

14– curved return

15– curved angle return

16– curved no return

17– gullwing no return

Knobs

4– round

(page 11)

MS– magnetic stripe

PM– proximity

Motorola

PH– proximity

HID

MSA– other cylinder

PHA– other cylinder

PMA– other cylinder

(page 11)

605

611

613

619

626

606

612

618

625

690

**Must specify key mark and number of keys or designate L/C for less core. †See H Series catalog for details.

RH

Handing

RH

RHRB

LH

LHRB

KNL

Options†

SH – security head screws

TAC – tactile lever

Thick

Door – specify thickness if other than 1 3 /

4

"

7/8" LTC– flat lip strike

1300 – B.A.S.I.S. direct connect

(page 3)

I D H M A X ® & E L E C T R O

Function

DEL–Locked

Fail Safe

Latch

Operated by

• Outside knob/lever when power is removed from the solenoid

• Outside key

• Inside knob/lever.

Locked by

40HM IDH MAX ®

Outside Knob/Lever

Applying power to solenoid; remains locked while power is on.

Unlocked by

Removing power from solenoid

– FUNCTIONS

Inside Knob/Lever

Locked by Unlocked by

Cannot be locked Always unlocked

DEU–Unlocked

Fail Secure

Powered by 12 DC. temperature control module is not needed.

• Outside knob/lever when power is removed from the solenoid

• Outside key

• Inside knob/lever.

Removing power from solenoid

Applying power to solenoid; remains locked while power is on.

Cannot be locked Always unlocked

NXEL–Locked

Fail Safe

NXEU–Unlocked

Fail Secure

TDEL–Locked

Fail Safe

TDEU–Unlocked

Fail Secure

LEL–Locked

Fail Safe

LEU–Unlocked

Fail Secure

Powered by 12 DC. temperature control module is not needed.

• Outside knob/lever when power is removed from the solenoid

• Inside knob/lever.

Applying power to solenoid; remains locked while power is continuously applied.

Removing power from solenoid

Latchbolt is deadlocked by an auxiliary latch

Powered by 12 DC. temperature control module is not needed.

• Outside knob/lever when power is removed from the solenoid

• Inside knob/lever.

Removing power from solenoid

Applying power to solenoid; remains locked while power is continuously applied.

Latchbolt is deadlocked by an auxiliary latch

Powered by 12 DC. temperature control module is not needed.

• Outside key

• Outside knob/lever when power is removed from the solenoid.

Latchbolt is deadlocked by an auxiliary latch

Applying power to the solenoid; remains locked while power is continuously applied

Deadbolt operated by:

Outside key

Removing power from the solenoid

Deadbolt and Latchbolt retracted simultaneously by:

• Inside knob/lever

• Outside knob/lever when power is removed

Powered by 12 DC. temperature control module is not needed.

• Outside key

• Outside knob/lever when power is removed from the solenoid.

Latchbolt is deadlocked by an auxiliary latch

Removing power from the solenoid

Deadbolt operated by:

Outside key

Applying power to the solenoid; remains locked while power is continuously applied

Deadbolt and Latchbolt retracted simultaneously by:

• Inside knob/lever

• Outside knob/lever when power is removed

Powered by 12 DC. temperature control module is not needed.

• Outside knob/lever when power is removed from the solenoid

• Inside knob/lever.

Applying power to the solenoid; remains locked while power is continuously applied

Deadbolt extended by:

Inside thumb turn

Removing power from the solenoid

Deadbolt retracted by:

• Inside thumb turn

• Inside knob/lever retracts the deadbolt and latchbolt simultaneously

• Outside lever when power is removed

Powered by 12 DC. temperature control module is not needed.

• Outside knob/lever when power is applied to the solenoid

• Inside knob/lever.

Removing power from the solenoid

Deadbolt extended by:

Inside thumb turn

Applying power to the solenoid; remains locked while power is continuously applied

Deadbolt retracted by:

• Inside thumb turn

• Inside knob/lever retracts the deadbolt and latchbolt simultaneously

• Outside knob/lever when power is removed

Powered by 12 DC. temperature control module is not needed.

Cannot be locked

Cannot be locked

Cannot be locked

Cannot be locked

Cannot be locked

Cannot be locked

OMECHANICAL LOCKS

Always unlocked

Always unlocked

Always unlocked

Always unlocked

Always unlocked

Always unlocked

5

6

9KM IDH MAX ®

MECHANICAL

– SPECIFICATIONS

Materials— Internal parts are brass, zinc or corrosion-treated steel.

Chassis— 2 1 ⁄

16

" diameter to fit 2 1 ⁄

8

" diameter hole in door.

Strike— Brass or bronze, 4 7 ⁄

8

" x 1 1 ⁄

4

" x 3 ⁄

32

". Fits standard door frame cut out as specified in ANSI A115.1. Correct strike automatically supplied with unit.

Strike box supplied standard.

Backset— 2 3 ⁄

4

" standard, 3 3 ⁄

4

" and 5" available.

Door thickness— For doors 1 3 ⁄

4

" – 2 1 ⁄

4

"

Installation— Lock dimensions requires modified door prep ANSI A156.2

Series 4000, Grade 1 to mount housing.

Latchbolt— 9 ⁄

16

" throw.

Die cast trim housing— Dimensions: 10 3 ⁄

8

" H x 3 1 ⁄

4

" W x 1" D sloping down to

Knobs— Diameter: 2 1 ⁄

8

" Projection on door: 2 7 ⁄

8

"

3 ⁄

4

".

#4, #6 knobs: Material machined from brass or bronze.

Lever handle— Made from high-quality zinc alloy. Body is approximately 1 5 ⁄

8

" in diameter: Handle is approximately 4 3 ⁄

4

" in length (from center-line of chassis).

(Lever #14,15 conform to California Titles 19 and 24.)

Finish— 605-bright brass, clear coated; 606-satin brass, clear coated; 611-bright bronze, clear coated; 612-satin bronze, clear coated; 613-oxidized satin bronze, oil rubbed

625-bright chromium plated; 626-satin chromium plated; 690-dark bronze.

93KM IDH MAX ®

ELECTRONIC

Maximum current draw: 850 MilliAmps, for 50 milliseconds

Typical current draw (hold condition): 550 milliAmps

Voltage: 10.2 to 13.2 V

Operating Temperature:

Minimum/Maximum range Inside: 70˚± 4˚F (21˚± 2˚C) Outside: -31˚F (-35˚C) to +151˚F (+66˚C)

Cylindrical

Magnetic Stripe Card Reader:

Read Rate: 5 inches per second to 50 inches per second.

Card thickness: ISO standard .030" ± .003 thick. Compliance to FCC, Canadian, and European EMC requirements; for interference FCC Class A digital apparatus.

Magnetic Stripe adaptation: Trim option that can accept other manufacturers cylinder.

Proximity Reader:

ANSI/BHMA A156.25 compliant, Compatible with Motorola / Indala and HID proximity cards, ABA and Wiegand output

Weatherproof bezel and gasket provide protection for outdoor use. (Usable in all environmental/exterior applications).

Card Read Range: 0 – 3 inches. Compliance to US FCC, Canadian FCC, and European EMC requirements

ESD Protection: 15 Kilo Volt

9KM/8KM IDH MAX ® – HOW TO ORDER

93KM 7 DDEU 14 MS STK

Series Core

Housing

Function Lever*/Knob

Style

Trim*

Style

Strike

Package

Lever

93KM– 2 3 /

4

"

94KM– 3 3 /

4

"

95KM– 5"

Knob

83KM– 2 3 /

4

"

84KM– 3 3 /

4

"

85KM– 5"

0– keyless

7– 7 pin housing accepts all BEST cores

DDEU– electricallyunlocked

DDEL– electricallylocked

(page 7)

Lever

14– curved return

15– contour angle return

16– curved no return

Knob

4– round

6– tulip

(page 11)

MS– magnetic stripe

PM– proximity

Motorola

PH– proximity

HID

(page 11)

STK– 2 3 /

4

"

ANSI

S3– 4 7 /

8

"

ANSI

626

Finishes*

605 606

611 612

613 618

619 625

626 690

TL

Options

8KM:

BRK – breakaway knob

KNL – knurled knob

TAC – tactile knob

9KM:

AL – abrasive lever

LM – lost motion

TL – tactile lever

Note: specify inside (I), outside

(O), or both (B) for AL, TL,TAC,

KNL options

Both 8KM & 9KM:

SH – security head screws

3

/

4 –

3

/

4

" throw latch

1300 – Integrated BAS1300/

LNL1300 reader electronic board

(page 3)

* Handles and trim are made from a zinc alloy, and have been plated to be equivalent in appearance to the finishes listed.

IDH MAX ® & ELECTROMECHANICAL LOCKS

Function Latch

Operated by

DDEL–Locked • Rotating the inside knob/lever, OR

• Rotating the outside knob/lever—only when power is off, OR

• Turning the key in the out side knob/lever.

9KM IDH MAX ®

Outside Knob or Lever

Locked by Unlocked by

– FUNCTIONS

Inside Knob or Lever

Locked by Unlocked by

Switching off 12 volts DC Cannot be locked Always unlocked Applying 12 volts DC.

The outside knob/lever remains locked only while power is on.

Powered by 12 DC. temperature control module is not needed.

DDEU–Unlocked • Rotating the inside knob/lever, OR

• Rotating the outside knob/lever—only when power is on, OR

• Turning the key in the out side knob/lever.

Switching off 12 volts DC Applying 12 volts DC.

The outside knob/lever remains locked only while power is off.

Powered by 12 DC. temperature control module is not needed.

Cannot be locked Always unlocked

Shading indicates a ridged lever/knob in a non-energized state.

40HW ELECTRIFIED – SPECIFICATIONS

The 40HW electromechanical locks provide a way to lock or unlock a door from a remote location for safety, convenience, or security. The 8KW/9KW cylindrical and

40HW mortise locks in fail-safe or fail-secure operation. These locksets can be controlled by an individual switch, switch lock, relay, access control or other automatic control system. As expected, the 8KW/9KW and 40HW electromechanical locks exhibit the same features and meet the same specifications as our standard 8K/9K cylindrical and 40H mortise locksets.

Types:

• 12 volts AC or DC — 1.10 amps

• 24 volts AC or DC — 0.75 amps

All EU functions: Electrically Unlocked (Fail Secure)

All EL functions: Electrically Locked (Fail Safe)

Approval Listings:

• UL listed for GYQS Electrically-controlled singlepoint locks or latches.

• This product has been approved by the California State Fire Marshal (CSFM) pursuant to section 13144.1 of the California Health and Safety Code.

• Approved by the city of New York Board of Standards and Appeals under calendar number 49-88-SA. See CSFM listing No. 4136-1175:101 for allowable values and/or conditions fo use concerning material presented in this document. It is subject to re-examination,revisions and possible cancellation.

NOTE: A Temperature Control Module (TCM) may be needed when a lockset is energized for long periods of time. The TCM must be ordered separately for

"EU" functions, but is automatically included with 45HW "EL" functions.

40HW Mortise Electrically-

Operated Lockset

OMECHANICAL LOCKS

7

8

40HW ELECTRIFIED – HOW TO ORDER

45HW

Series

7

Core

Housing

NXEU

Function

12

Lever

Style

J

Trim

Style

612

Finishes

LH

Handing

45HW– lever

47HW– lever high security

45HW:

0– keyless or less cylinder,

7– 7 pin

47HW:

7– 7 pin

(accepts

5C cores only)

45HW/47HW:

DEL– single key latch, fail safe

DEU– single key latch, fail secure

WEL– double key latch, fail safe

WEU– double key latch, fail secure

TDEL– single key deadbolt, fail safe

TDEU– single key deadbolt, fail secure

TWEL– double key deadbolt, fail safe

TWEU–double key deadbolt, fail secure

Levers:

3– solid tube/ return

12– solid tube/ no return

14– curved return

15– contour/ angle return

16– curved/no return

17– gullwing no

4– round return

Knobs:

45HW:

H– 2 9 /

16

" dia.

J– wrought

M– forged

N– forged concealed cylinder

S– 3 1 /

2

" dia.

47HW:

M– forged

45HW:

605 606

611 612

613 618

619

626

47HW:

626

625

690

630

RH

RHRB

LH

LHRB

45HW only:

NXEL– keyless, latch, fail safe

NXEU– keyless, latch, fail secure

LEL– keyless, deadbolt, fail safe

LEU– keyless, deadbolt, fail secure

(pages 8–9) (page 11) (page 11)

* “N” trim not available on double keyed functions. **Must specify key mark and number of keys or designate L/C for less core.

†See H Series catalog for details.

40HW ELECTRIFIED – FUNCTIONS

Function Latch

Operated by

Outside Knob or Lever

Locked by Unlocked by

DEL–Locked

Fail Safe

• Outside knob/lever when power is removed from the solenoid

• Outside key

• Inside knob/lever.

Applying power to solenoid; remains locked while power is on.

Removing power from solenoid

RQE

Options†

AL – abrasive lever

IDH – integrated door hardware

LL – lead lined

LS – latch status

RQE – request to exit

SH – security head screws

TL – tactile lever

Thick

Door – specify thickness if other than 1

3

/

4

"

(page 3)

Inside Knob or Lever

Locked by Unlocked by

Cannot be locked Always unlocked

DEU–Unlocked

Fail Secure

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Temperature control module (TCM) included.

• Outside knob/lever when power is removed from the solenoid

• Outside key

• Inside knob/lever.

Removing power from solenoid

Applying power to solenoid; remains locked while power is on.

Cannot be locked Always unlocked

WEL–Locked

Fail Safe

WEU–Unlocked

Fail Secure

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty.

• Inside and Outside knob/lever when power is removed from the solenoid

• Inside/Outside key

Latchbolt is deadlocked by an auxiliary latch

Applying power to solenoid; remains locked while power is continuously applied.

Removing power from solenoid Applying power to the solenoid; remains locked while power is continuously applied

Removing power from the solenoid

Temperature control module (TCM) included.

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.

• Inside and Outside knob/lever when power is applied to the solenoid

• Inside/Outside key

Latchbolt is deadlocked by an auxiliary latch

Removing power from solenoid

Applying power to solenoid; remains locked while power is continuously applied

Switching off 24 volts AC/DC. Inside knob/lever remains locked only while power is off.

Applying 24 volts

AC/DC. Inside knob/lever remains unlocked only while power is on.

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.

IDH MAX ® & ELECTROMECHANICAL LOCKS

Function

TDEL–Locked

Fail Safe

TDEU–Unlocked

Fail Secure

TWEL–Locked

Fail Safe

TWEU–Unlocked

Fail Secure

NXEL–Locked

Fail Safe

NXEU–Unlocked

Fail Secure

LEL–Locked

Fail Safe

LEU–Unlocked

Fail Secure

Latch

Operated by

40HW ELECTRIFIED – FUNCTIONS (CONTINUED)

Outside Knob or Lever

Locked by Unlocked by

Inside Knob or Lever

Locked by Unlocked by

• Outside key

• Outside knob/lever when power is removed from the solenoid.

Latchbolt is deadlocked by an auxiliary latch

Applying power to solenoid; remains locked while power is continuously applied.

Deadbolt operated by:

Outside key

Removing power from solenoid

Deadbolt and latchbolt retracted simultaneously by:

• Inside knob/lever

• Outside knob/lever when power is removed.

Cannot be locked Always unlocked

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Temperature control module (TCM) included.

• Outside key

• Outside knob/lever when power is applied to the solenoid.

Latchbolt is deadlocked by an auxiliary latch

Removing power from solenoid

Deadbolt operated by:

Outside key

Applying power to solenoid; remains locked while power is continuously applied.

Deadbolt and latchbolt retracted simultaneously by:

• Inside knob/lever

• Outside knob/lever when power is removed.

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty.

Cannot be locked Always unlocked

• Outside & inside key

• Outside & Inside knob/lever when power is removed from the solenoid.

Latchbolt is deadlocked by an auxiliary latch

Applying power to solenoid; remains locked while power is continuously applied.

Deadbolt operated by:

• Outside or inside key

• Outside & Inside knob/ lever when power is removed from the solenoid

Removing power from solenoid Applying power to solenoid; remains locked while power is continuously applied.

Removing power from solenoid

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.

• Outside & inside key

• Outside & Inside knob/lever when power is applied to the solenoid.

Latchbolt is deadlocked by an auxiliary latch

Removing power from solenoid

Deadbolt operated by:

• Outside or inside key

• Outside & Inside knob/ lever when power is removed from the solenoid

Applying power to solenoid; remains unlocked while power is continuously applied.

Removing power from solenoid

Applying power to solenoid; remains locked while power is continuously applied.

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Applying voltage locks inside & outside knobs/levers simultaneously.

• Outside knob/lever when power is removed from the solenoid

• Inside knob/lever.

Latchbolt is deadlocked by an auxiliary latch

Applying power to solenoid; remains locked while power is continuously applied.

Removing power from solenoid

Cannot be locked Always unlocked

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Temperature control module (TCM) included.

• Outside knob/lever when power is removed from the solenoid

• Inside knob/lever.

Latchbolt is deadlocked by an auxiliary latch

Removing power from solenoid

Applying power to solenoid; remains locked while power is continuously applied.

Cannot be locked

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty.

• Outside knob/lever when power is removed from the solenoid

• Inside knob/lever.

Applying power to the solenoid; remains locked while power is continuously applied

Deadbolt extended by:

Inside thumb turn

Removing power from the solenoid Cannot be locked

Deadbolt retracted by:

• Inside thumb turn

• Inside knob/lever retracts the deadbolt and latchbolt simultaneously

• Outside knob/lever when power is removed

Always unlocked

Always unlocked

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty. Temperature control module (TCM) included.

• Outside knob/lever when power is applied to the solenoid

• Inside knob/lever.

Removing power from the solenoid

Deadbolt extended by:

Inside thumb turn

Applying power to the solenoid; remains locked while power is continuously applied

Deadbolt retracted by:

• Inside thumb turn

• Inside knob/lever retracts the deadbolt and latchbolt simultaneously

• Outside knob/lever when power is removed

Powered by 12 or 24 volts AC/DC & 1.10 or 0.75 amps, continuous duty.

Cannot be locked Always unlocked

ATTENTION: Locksets that secure both sides of the door are controlled by building codes and the Life Safety Code ®

.

In an emergency exit situation, failure to quickly unlock the inside lever could be hazardous or even fatal.

OMECHANICAL LOCKS

9

8KW & 9KW ELECTRIFIED LOCKS – SPECIFICATIONS

Types:

• 24 volts DC only — 0.18 amps intermittent or continuous duty.

EU: Electrically Unlocked (Fail Secure)

EL: Electrically Locked (Fail Safe)

Approval Listings:

• UL listed for GYQS Electrically-controlled singlepoint locks or latches.

• This product has been approved by the California State Fire

Marshal (CSFM) pursuant to section13144.1 of the California

Health and Safety Code.

• Approved by the city of New York Board of Standards and

Appeals under calendar number 730-89-SA. See CSFM listing No.

4136-1175:103. It is subject to re-examination, revision and possible cancellation.

93KW Cylindrical Electrically-Operated Lockset

† NOTE:

8KW/9KW Electromechanical locksets are intended for use on 1

3

/

4

" minimum thick doors. Consult your local Stanley office when installing

8KW/9KW electromechanical locksets on doors less than 1

3

/

4

" thick.

10

8KW & 9KW ELECTRIFIED LOCKS – HOW TO ORDER

93KW 7 DEU 14 K STK 626 TL

Series Core

Housing

Function Knob/Lever

Style

Trim

Style

Strike

Package

Finishes* Options

8KW:

83KW– 2 3 /

4

"

84KW– 3 3 /

4

"

85KW– 5"

9KW:

93KW– 2 3 /

4

"

94KW– 3 3 /

4

"

95KW– 5"

0– keyless

7– 7 pin housing accepts all Best cores

DEU– electricallyunlocked

DEL– electricallylocked

8KW:

4– round

6– tulip

9KW:

14– curved return

15– contour angle return

16– curved no return

C– 3" convex

D– 3 1 /

2

" convex

K– 3" convex— no ring

L– 3 1 /

2

" convex

—no ring

STK

2 3 /

4

" ANSI

S3

4 7 /

8

" ANSI

605 606

611 612

613 618

619 625

626 690

(See Below) (page 11) ( page 11)

* Handles are made from a zinc alloy, and have been plated to be equivalent in appearance to the finishes listed.

8KW only:

BRK– breakaway knob

KNL– knurled knob

TAC– tactile knob

9KW only:

AL– abrasive lever

LM– lost motion

RQE– request-to-exit

TL– tactile lever

Note: specify inside (I), outside

(O), or both (B) for AL, TL, TAC,

KNL options

8KW & 9KW:

LL– lead lined

SH– security head screws

3

/

4 – 3

/

4

" throw latch

( page 3)

8KW & 9KW ELECTRIFIED LOCKS – FUNCTIONS

Function Latch

Operated by

Outside Knob or Lever

Locked by Unlocked by

Inside Knob or Lever

Locked by Unlocked by

DEL-Locked • Rotating the inside knob/lever, OR

• Rotating the outside knob/lever—only when power is off, OR

• Turning the key in the outside knob/lever.

Applying 24 volts DC.

The outside knob/lever remains locked only while power is on.

Switching off 24 volts DC.

Locks are powered by 24 volts DC and 0.18 amps, continuous duty.

Cannot be locked.

Always unlocked.

DEU-Unlocked • Rotating the inside knob/lever, OR

• Rotating the outside knob/lever—only when power is on, OR

• Turning the key in the outside knob/lever.

Switching off 24 volts DC. Applying 24 volts DC.

The outside knob/lever remains locked only while power is off.

Locks are powered by 24 volts DC and 0.18 amps, continuous duty.

Shading indicates a ridged lever/ knob in a non-energized state.

Cannot be locked.

Always unlocked.

IDH MAX ® & ELECTROMECHANICAL LOCKS

KNOB TRIM VARIATIONS

#4 knob #6 knob

LEVER TRIM VARIATIONS

#3 lever #12 lever

MORTISE ROSE TRIM

#14 lever #15 lever

#16 lever #17 lever

CYLINDRICAL ROSE TRIM

H Rose S Rose C Rose D Rose K Rose L Rose

ESCUTCHEON TRIM VARIATIONS

J Escutcheon M Escutcheon N Escutcheon MS Escutcheon

M E C H A N I C A L L O C K S

Prox Escutcheon

11

12

ELECTRIFIED ACCESSORIES

8W599

Features

Offers exceptionally high power for its compact size

UL listed

Thermally fused

Convenient 4 point mounting provision allows rapid installation in a standard 1 /

2

" knockout

Foot-mounts for surface installation

Pre-stripped pigtails provided for quick primary connection

Secondary connection by screw terminals

Sturdy nylon bobbin construction

Cadmium plated finish

Specifications

Primary voltage: 120 VAC (Wire Leads)

Secondary voltage: 24 VAC (Screw Terminals)

Secondary VA: 40 volts-amperes

Dimensions: 2 1 /

4

" x 2 1 /

8

" x 2 15 /

16

"

To order specify: 8W599

Transformer

Function/Application

Transforms 120 volts AC to 24 volts AC. (To get 24 volts

DC, use with 8WCON, AC to DC converter.) Typically used as a power supply for electrically-operated locks.

8WCON

Features

400 Ampere surge capability

Electrically isolated base

UL recognized

Single-phase, full wave bridge

Specifications

Average forward current: 25 amps

Case: Plastic case with an electrically isolated aluminum base

Polarity: Terminal designation embossed on case: +DC output,

-DC output, AC not marked

Mounting position: Bolt down. Gain the highest heat transfer efficiency through the surface opposite the terminals. Use silicone heat sink compound on mounting surface for maximum heat transfer.

Terminals: Suitable for “fast-on” connections. Readily solderable and corrosion resistant. Soldering is recommended for applications greater than15 amperes.

Mounting torque: 20 inch-pounds maximum

Case size: 1.030 x 1.030 inches

Temperature range: -85° to 347°F (-65° to + 175°C)

To order specify: 8WCON

AC to DC Converter

Full wave bridge rectifier

Function/Application

Converts AC (alternating current) to DC (direct current) for locking circuit applications. (Typically used with

8W599 transformer.)

8WBU-1-A / 8WBU-1-N

Features

• Positive “snap” feedback

Industrial-grade switch designed for rugged control applications

Factory assembled with trimplate

Standard or narrow plate available

1 3 /

16

" dia. mushroom head—red in color

Specifications

Electrical rating: 28VDC or 115 VAC, 10A resistive, 5A inductive,

3A lamp load (see terminology on the back cover)

Switch type: SPST-NO-DB, FORM-X contacts, 25,000 cycles at

8WBU-1-A

Standard plate

8WBU-1-N

Narrow plate full load, 50,000 cycles mechanical life

Mounting hole:

5

/

8

" (.625) dia.

Function/Application

Switch dim.: 1.187 dia.x 1.528 overall length

Std. wall plate: 2

3

/

4

" x 4

1

Narrow wall plate: 1

1

/

2

"

/

2

" x 4

1

/

2

"

Normally open push-button switch provides momentary switch closure when pressed. Typically used to momentarily energize electrified locks or strikes or used as a request-to-

Material/finish: Satin stainless steel exit switch on access control systems.

Wire leads: Two 6" long 20 AWG insulated wire leads

To order specify: 8WBU-1-A standard plate 8WBU-1-N narrow plate

IDH MAX ® & ELECTROMECHANICAL LOCKS

Features

All circuitry completely sealed

Wire leads for easy installation

Through hole mounting

Usable on other manufacturer’s 12 & 24 VDC locksets

Specifications

Wire leads: 18 AWG stranded vinyl insulated wire approx. 6" in length

Voltage input: 24 volts AC/DC

Voltage output: 12 volts DC; 24 volts DC minimum at one (1) amp max. load for approx. one (1) second, then 15 to 17 VDC regulated output until input voltage is interrupted.

Output protection: Short circuit current limiting set at one (1) amp; output reverse hookup protection for internal circuitry only.

Operating temp: -4 to 158°F (-20 to 70°C)

Size: 2" x 2 1 /

8

" x 1 3 /

8

"

To order specify: 8WTCM

ELECTRIFIED ACCESSORIES

8WTCM

Temperature control module

Function/Application

A temperature control module (TCM) reduces the amount of current flow to a lockset one second after energizing, thereby lowering the temperature of the lockset trim. A TCM may be needed on an electrified mortise or electrified cylindrical lockset if energized for long periods of time. The TCM is not used with any IDH-Max function. The TCM Must Be ordered separately for DEL, WEU, NXEU functions, but is automatically included with 44H–47H DEL\, WEL,

NXEL functions.

TERMINOLOGY

Closed–A state in which a connection exists between the common terminal and another terminal on the switch. See also Open.

Common terminal–A terminal on a switch whose contact can be connected to one or more terminals on the switch.

Door monitor switch–A switch that monitors whether the door is open or closed. This switch is used to detect a forced entry, or a door that is propped open.

Inductive load–An electrical device such as a motor, relay, or solenoid. Note: this type of load can cause arcing across switch contacts and may burn the contacts. See also Resistive load and Lamp load.

Lamp load –An electrical device that produces light using a tungsten filament, such as an incandescent light bulb. Note: this type of load can cause surges of current upon contact closure. This may cause the contacts to weld together. See also

Inductive load and Resistive load.

Maintained–Remaining in a given state until the switch lever or button is actuated. Actuating the switch lever or button causes the switch to change to another maintained state.

Momentary–Remaining in a given state only as long as an external force is applied to the switch lever or button.

NC–(Normally Closed) Switch contacts that are closed as long as no external force is applied to the switch lever or button

NO–(Normally Open) Switch contacts that are open as long as no external force is applied to the switch lever or button.

Open–A state in which no connection exists between the common terminal or any other terminal on the switch.

Pole–The number of independent circuits in a switch. For example, a double-pole, single-throw switch can control two separately powered motors. See also Throw.

Resistive load–An electrical device, such as a heater, having none of the characteristics of an inductive or lamp load. This type of load is the least severe on the switch because only a small amount of arcing occurs when the switch contacts open and close. See also Inductive load and Lamp load.

RQE–Request-to-exit. A switch that allows the user to exit without setting off an alarm. The 34–37H mortise lock can be supplied with an internal request-to-exit switch. Turning the inside knob or lever actuates the switch and, when wired to an alarm system, sends a signal to disable or sound an alarm, start a timer, etc.

Throw–The number of circuits, or contacts controlled by each pole. For example, a single-pole, double-throw switch can control a motor with two contacts—a forward contact, and a reverse contact. See also Pole.

1300– Integrated BAS1300/LNL1300 reader electronics board or (ISC) Intelligent System Controller is embedded behind the escutcheon secured and out of site. Functions with B.A.S.I.S./Mercury on-line equipment only.

OMECHANICAL LOCKS

13

ELECTRIC SWITCH LOCK – INTRODUCTION

Stanley Security Solutions offers a line of electric switch locks available in various “on-off” and “momentary” keyed switch functions.

Circuitry variations are available in single, double and triple pole with varied voltage and amperage ratings. Units may be keyed into any BEST system. The BEST interchangeable core offers versatility and adaptability for new and existing electrical controls, panels, machines, etc.

Features

• Double D lock cylinder prevents slipping and turning

• Screw terminals on all switch locks (except the 1W7A1) provides ease of installation

• All switches are UL recognized or listed

Note on functionality: Switch lock keys can only be removed in the 12 o’clock position.

How to select a switch lock

1. Determine the electrical requirements for the device being controlled:

A. Voltage (for example: 115 VAC or 24 VDC)

B. Current or horsepower (for example: 6 amps or

1 /

2 horsepower)

C. Type of load

• Resistive (for example, heater elements)

• Inductive (for example, motors, large transformers)

• Lamp (for example, incandescent lights)

2. Determine the switch configuration (poles and throws) and key removal condition:

A. Poles To determine the number of poles, find how many wires from the power source need to be switched on and off by the switch lock.

B.

Throws To determine the number of throws, find how many wires to the device the switch needs to control. For example, if a switch needs two different “on” conditions (low and high speed), two throws are needed. Or if the device is simply an “on-off” type (only one wire), you need one throw.

Note: A switch throw may be left unwired and used as an “off” condition.

C. Key removal To determine the key removal condition, ask the question, “When the key is removed, should the switch be

“off”, or could the switch be either “on” or “off” ?” Although the key can only be removed in the 12 o’clock position, the switch itself may be left in two or three positions. Check each switch lock for key removal switch positions.

3. Use the information collected and find the switch lock that best meets the requirements. Refer to the following catalog pages for a description of each switch lock. If environmental conditions make it necessary that the switch lock be housed in an electrical box, see the Optional boxes (above) for the box that best suits the switch lock and your application.

OPTIONAL BOXES

14

OC1

Standard octagon center mount

3 1 /

2

" x 3 1 /

2

" x 1 5 /

8

"

OC2

Deep octagon offset mount

3 1 /

2

" x 3 1 /

2

" x 3 1 /

4

"

INT

Interior box

4" x 2 1 /

8

" x 1 7 /

8

"

SWR

Standard weather resistant box

4 5 /

8

" x 2 7 /

8

" x 2 1 /

4

"

HOW TO ORDER – 1W ELECTRIC SWITCH LOCK

1W

Series

7

Core

Housing

1W 7– 7 pin housing accepts all

Best cores

B1

Function Finishes see pages

15–19

626

605 606

611 612

613 619

622 625

626 690

SWR

Box see above

DWR

Deep weather resistant box

4 5 /

8

" x 2 7 /

8

" x 3"

IDH MAX ® & ELECTROMECHANICAL LOCKS

1W ELECTRIC SWITCH LOCKS

1W7A1

Contacts ..............................................................................................Silver or gold flash

Contact rating ..........................................................................28 VDC, 10 amps resistive

28 VDC, 3 amps inductive, lamp

125 VAC, 10.1 amps resistive

250 VAC, 10.1 amps resistive

Horsepower rating ..................................................................................125 VAC, 1 /

4

HP

Operating temperature ................................................-85°F to +257°F (-65° to +125°C)

Switch type ....................................................................SPDT (Single pole-double throw)

Switch lock action ..............................................................................Maintained (on-on)

Number of switches per assembly ............................................................................One

2 1 /

16

"

1W7A1

31

/ 32 "

1

5

/

32

"

5 /

16

"

Hole cutout

Key & switch positions

Key pos.1– Swt. pos.1

15 /

16

"

Back view

Key pos.2– Swt. pos.2

3 /

4

"

1 /

8

"

Side view

Remove key Optional boxes

DWR

INT

OC1

OC2

Key pos. 1only Swt.

1W7B1 & 1W7J1

Contact rating ........................................................................30 VDC, 15 amps, resistive

125 VDC, 0.6 amps, resistive

250 VDC, 0.3 amps, resistive

125 VAC, 15 amps, resistive

25 VAC, 5 amps, lamp

250 VAC, 15 amps, resistive

Horsepower rating ..........................................................................125–250 VAC, 1 /

2

HP

Operating temperature ....................................................................up to +176°F (+80°C)

Switch type ....................................................................SPDT (Single pole-double throw)

Switch lock action ..............................................................................Maintained (on-on)

Number of switches per assembly ........................................1W7B1: One 1W7J1: Two

1W7B1—One switch

31 /

32

"

1 5 /

32

"

Hole cutout

Key & switch positions

Back view Side view

The shaded area shows the additional 1W7J1 switch and cam length.

Remove key Optional boxes

OC1 DWR

OC2 INT

SWR (1W7B1 only)

Key pos.1– Swt. pos.1 Key pos.2– Swt. pos.2 Key pos. 1 only

Swt. pos. 1

OMECHANICAL LOCKS

1W7J1—Two switches

15

1W ELECTRIC SWITCH LOCKS

1W7B2 & 1W7J2

Contact rating .................................................................. 30 VDC, 15 amps, resistive

125 VDC, 0.6 amps, resistive

250 VDC, 0.3 amps, resistive

125 VAC, 15 amps, resistive

125 VAC, 5 amps, lamp

250 VAC, 15 amps, resistive

Horsepower rating ......................................................................125–250 VAC, 1 /

2

HP

Operating temperature ..............................................................up to +176°F (+80°C)

Switch type ..............................................................SPDT (Single pole-double throw)

Switch lock action ..........................................................................Maintained (on-on)

Number of switches per assembly ..................................1W7B2: One 1W7J2: Two 1W7B2—One switch

31 /

32

"

1 5 /

32

"

Hole cutout

Back view

The shaded area shows the additional 1W7J2 switch and cam length.

Key & switch positions

Side view

Remove key Optional boxes

OC1 DWR

OC2 INT

SWR (1W7B2 only)

Key pos.1– Swt. pos.1 Key pos. 2

(360°CCW)

Swt. pos. 2 Key pos. 1 and 2

Swt. pos. 1 and 2

1W7B3 & 1W7J3

Contact rating .................................................................. 30 VDC, 15 amps, resistive

125 VDC, 0.6 amps, resistive

250 VDC, 0.3 amps, resistive

125 VAC, 15 amps, resistive

125 VAC, 5 amps, lamp

250 VAC, 15 amps, resistive

Horsepower rating ....................................................................125–250 VAC, 1/2 HP

Operating temperature ..............................................................up to +176°F (+80°C)

Switch type ..............................................................SPDT (Single pole-double throw)

Switch lock action ........................................................................Momentary (on-on)

Number of switches per assembly ..................................1W7B3: One 1W7J3: Two

31 /

32

"

1 5 /

32

"

1W7J2—Two switches

1W7B3—One switch

16

Hole cutout

Back view

The shaded area shows the additional 1W7J3 switch and cam length.

Key & switch positions Remove key

Side view

Optional boxes

OC1 DWR

OC2 INT

SWR (1W7B3 only)

1W7J3—Two switches

Key pos.1– Swt. pos.1 Key pos.2– Swt. pos.2 Key pos.1– Swt. pos.1

IDH MAX ® & ELECTROMECHANICAL LOCKS

1W ELECTRIC SWITCH LOCKS

1W7D2

Contact rating . . . . . . . . . . . . . . . . . . . . . . . . . .110 VAC or VDC, 16 amps, resistive

220 VAC or VDC, 8 amps, resistive

Horsepower rating . . . . . . . . . . . . . . . . . . . . . . . . . . .1 HP @ 125–250 VAC or VDC

Operating temperature . . . . . . . . . . . . . . . . . . . . . . .0°F to +150°F (-18°C to +66°C)

Switch type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DPST (Double pole-single throw)

Switch lock action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maintained (off-on)

Number of switches per assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .One

7 /

8

"

1 5 /

32

"

1W7D2

Hole cutout

Limiting plate†

Key & switch positions

Side view

Remove key

Front view

Optional boxes

OC2 DWR

INT SWR

Key pos.1– Swt. pos.1 Key pos.2– Swt. pos.2 Key pos. 1 only

Swt. pos. 1 and 2†

†Installing the limiting plate limits key removal to switch position 1 or 2. The key is always removed in the vertical position (key position 1).

1W7C2

Contact rating ..............................................................110 VAC or VDC, 10 amps, lamp

220 VAC or VDC, 5 amps, resistive

Operating temperature ................................................-40°F to +220°F (-40° to +104°C)

Switch type ......................................................................SPST (Single pole-single throw)

Switch lock action ..............................................................................Maintained (off-on)

Number of switches per assembly ............................................................................One

1W7C2

Front (inside) view

Key & switch positions

Side (inside) view

Remove key Optional boxes

OC1

OC2

Key pos.1– Swt. pos.1 Key pos.2– Swt. pos.2 Key pos. 3 only

Swt. pos. 1 and 2

OMECHANICAL LOCKS

17

1W ELECTRIC SWITCH LOCKS

1W7E2

Contact rating 110 VAC, 15 amps, resistive

Horsepower rating

220 VAC, 10 amps, resistive

125–250 VAC or VDC,

3

/

4

HP; 1, 2, or 3 phase

Operating temperature ........................................................0 to +150°F (-18°C to 66°C)

Switch type ....................................................................TPDT (Triple pole-double throw)

Switch lock action ............................................Maintained Momentary (on-center off-on)

Number of switches per assembly ............................................................................One

7 /

8

"

1 5 /

32

"

Hole cutout

1W7E2

Limiting plate *

Key & switch positions

Side view Front view

Remove key Opt. box

OC2

Key pos.1

Swt. pos.1

Key pos.2

Swt. pos.2

Key pos.3

Swt. pos.3

Key pos. 1 only

Swt. pos. 1, 2, and 3*†

*Installing the limiting plate limits key removal to switch position 2, or 3. The key is always removed in the vertical position (key position 1). The limiting plate is available for 1W7E2 only.

1W7K4

Contact rating ......................................................................110 VAC, 15 amps, resistive

220 VAC, 10 amps, resistive

Horsepower rating .................................................................................. 250 VAC, 1 /

2

HP

Operating temperature ..................................................................up to +221°F (+105°C)

Switch type ..................................................................DPDT (Double pole-double throw)

Switch lock action ..............................................................Momentary (on-center off-on)

Number of switches per assembly ............................................................................One

7 /

8

"

1 5 /

32

"

Hole cutout

Key & switch positions

1W7K4

Side view

Remove key

Back view

Opt. boxes

OC2

18

Key pos.1 Swt. pos.1 Key pos 2 Swt. pos.2 Key pos.3 Swt. pos.3 Key pos. 1 only

Swt. pos. 1 only

IDH MAX ® & ELECTROMECHANICAL LOCKS

1W ELECTRIC SWITCH LOCKS

1W7L2

Contact rating ..........................................................110 VAC or VDC, 12 amps, resistive

220 VAC or VDC, 6 amps, resistive

Operating temperature ..................................................................up to +221°F (+105°C)

Switch type ....................................................................SPDT (Single pole-double throw)

Switch lock action ..............................................................................Maintained (on-on)

Number of switches per assembly ............................................................................One

7 /

8

"

1 5 /

32

"

1W7L2

Hole cutout

Limiting plate

Key & switch positions

Side view

Remove key

Front view

Optional boxes

DWR

OC2

Key pos. 1

Swt. pos. 1

Key pos. 2

Swt. pos. 2

Key pos. 3 only

Swt. pos. 1 and 2†

†Installing the limiting plate limits key removal to switch position 1 or 2. The key is always removed in the vertical position (key position 3).

1W7P4 & 1W7R4

Contact rating ..........................................................................30 VDC, 15 amps, resistive

125 VDC, 0.6 amps, resistive

250 VDC, 0.3 amps, resistive

125 VAC, 15 amps, resistive

125 VAC, 5 amps, lamp

250 VAC, 15 amps, resistive

Horsepower rating ............................................................................125–250 VAC, 1 /

2

HP

Operating temperature ....................................................................up to +176°F (+80°C)

Switch type ....................................................................SPDT (Single pole-double throw)

Switch lock action ..............................................................................Momentary (on-on)

Number of switches per assembly ........................................1W7P4: Two 1W7R4: Four

1 1 /

2

"

2 5 /

16

"

1 29 /

32

"

31 /

32

"

1W7P4—two switches

1 5 /

32

" 2 7 /

8

"

1 /

8

"

Hole cutout

Back view

The shaded area shows the additional 1W7R4 switches and cam length.

Key & switch positions

Key pos.1 Swt. pos.1 Key pos.2 Swt. pos. 2

Side view

Remove key Boxes

SWR†

INT†

DWR

†1W7P4 only

Key pos.3 Swt. pos.3

Key pos. 1 only

Swt. pos. 1 only

OMECHANICAL LOCKS

1W7R4—four switches

19

For more information on Stanley Security Solutions’ products, services, and office locations visit our web site at www.stanleysecuritysolutions.com

Product information contained in this catalog has been compiled and presented with as much care and completeness as is reasonably possible. Errors or mistakes may be present, and in many cases, reliance has been placed on information supplied by other manufacturers which may be in error or which may be subject to changes or modifications by the manufacturer without notice and without obligation. Therefore, no guarantee can be made or should be assumed or implied with regards to product information contained in this catalog.

Stanley Security Solutions, Inc.

6161 E. 75th Street Indianapolis, Indiana 46250 www.stanleysecuritysolutions.com

© 2007 Stanley Security Solutions, Inc. and Stanley Logistics

010M 707FP

BAS019

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals