IntraChassis 9000

Ethernet Switch

User’s Manual

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Copyright Notice

All rights reserved. No part of this manual, or any associated artwork, software, product, design or design concept, may be copied, reproduced or stored, in whole or in part, in any form or by any means mechanical, electronic, optical, photocopying, recording or any other wise, including translation to another language or format, without the express written consent of Asanté Technologies, Inc.

Trademarks

Asanté Technologies and NetStacker are trademarks of Asanté Technologies, Inc. Ethernet is a registered trademark of the Xerox Corporation. A ll brand names and products are trademarks or registered trademarks of their respective holders.

FCC Information

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Operation of this equipment in a residential area is likely to cause interference, in which case, the user, at his or her own risk and expense, will be required to correct the interference.

LIMITED FIVE YEAR WARRANTY

Subject to the limitations and exclusions below, Asanté warrants to the original end user purchaser that the covered products will be free from defects in title, materials and manufacturing workmanship for a period of five years from the date of purchase. This warranty excludes fans, power supplies, non-integrated software and accessories. Asanté warrants that the fans and power supplies will be free from defects in title, materials and manufacturing workmanship for one year from date of purchase. Asanté warrants that nonintegrated software included with its products will be free from defects in title, materials, and workmanship for a period of 90 days from date of purchase, and the Company will support such software for the purpose for which it was intended for a period of 90 days from the date of purchase. This warranty expressly excludes problems arising due to compatibility with other vendors products, or future compatibility due to third party software or driver updates.

To take advantage of this warranty, you must contact Asanté for a return materials authorization (RMA) number. The RMA number must be clearly written on the outside of the returned package. Product must be sent to Asanté postage paid. In the event of a defect, Asanté will repair or replace defective product or components with new, refurbished or equivalent product or components as deemed appropriate by Asanté.

The foregoing is your sole remedy, and Asanté's only obligation, with respect to any defect or non-conformity. Asanté makes no warranty with respect to accessories (including but not limited to cables, brackets and fasteners) included with the covered product, nor to any discontinued product, i.e., product purchased more than thirty days after Asanté has removed such product from its price list or discontinued shipments of such product.

This warranty is exclusive and is limited to the original end user purchaser only. This warranty shall not apply to secondhand products or to products that have been subjected to abuse, misuse, abnormal electrical or environmental conditions, or any condition other than what can be considered normal use.

ASANTÉ MAKES NO OTHER WARRANTIES, EXPRESS, IMPLIED OR OTHERWISE, REGARDING THE

ASANTÉ PRODUCTS, EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL WARRANTIES OR

CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS-

CLAIMED. ASANTÉ’S LIABILITY ARISING FROM OR RELATING TO THE PURCHASE, USE OR INABILITY

TO USE THE PRODUCTS IS LIMITED TO A REFUND OF THE PURCHASE PRICE PAID. IN NO EVENT WILL

ASANTÉ BE LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES FOR THE

BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING ECONOMIC LOSS, DAMAGE TO PROP-

ERTY AND, TO THE EXTENT PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY, HOWEVER

CAUSED AND ON ANY THEORY OF LIABILITY (INCLUDING NEGLIGENCE). THESE LIMITATIONS SHALL

APPLY EVEN IF ASANTE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR IF THIS WAR-

RANTY IS FOUND TO FAIL OF ITS ESSENTIAL PURPOSE.

Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you.

This warranty gives you specific legal rights, and you may have other rights, which vary from jurisdiction to jurisdiction.

GLXY9.book Page iii Thursday, February 17, 2000 3:04 PM

Contents

1 Introduction ....................................................... 1-1

IntraCore Architecture Overview .................... 1-1

The Core Switching Engine ...................... 1-1

Infrastructure Connectivity ........................ 1-2

Network Management, Security, Performance, and

Control ...................................................... 1-2

The IntraCore Product Family ........................ 1-4

The IntraChassis 9000 ................................... 1-4

Modules ......................................................... 1-5

Network Management Module .................. 1-5

24-port 10/100 Switch Module .................. 1-6

2-port Gigabit Ethernet Switch Module ..... 1-6

Power Supply ........................................... 1-7

Features ......................................................... 1-8

Defaults and Specifications .......................... 1-10

LEDs ............................................................ 1-11

2 Installation and Set-up ..................................... 2-1

Installation Guidelines .................................... 2-1

Safety Information .................................... 2-1

Power Requirements ................................ 2-4

Environmental Requirements ................... 2-4

Cooling and Airflow ................................... 2-4

Installation Overview ...................................... 2-5

Rack Mounting/Desktop Placement ............... 2-5

Equipment Rack Installation of the Chassis 2-6

Free-Standing/Desktop Installation of the Chassis

2-8

Cable Guide Installation ........................... 2-8

Installing Modules .......................................... 2-9

Installing GBIC Interfaces ....................... 2-11

Page -iii

GLXY9.book Page iv Thursday, February 17, 2000 3:04 PM

Installing Second Power Supply ................... 2-11

Connecting Power ........................................ 2-11

Connecting to the Network ........................... 2-12

10/100BaseX Ports Cabling Procedures 2-12

1000BaseX Ports Cabling Procedures ... 2-13

Configuring for Management ........................ 2-13

BootP Configuration ................................ 2-14

Connecting To a Console ....................... 2-15

Management Options ................................... 2-16

Out-of-Band Management ...................... 2-16

In-Band Management ............................. 2-17

Management Interface ................................. 2-18

Accessing a Submenu ............................ 2-19

Exiting a Submenu .................................. 2-19

General Information Screen ......................... 2-19

Accessing General Information ............... 2-19

Configuration Menu ...................................... 2-20

Logging into the Configuration Menu ...... 2-20

Configuration Menu Options ................... 2-21

3 Basic Configuration ........................................... 3-1

Basic Configuration Overview ........................ 3-1

System Administration Configuration ............. 3-2

Current Settings ........................................ 3-2

Changing System Administration Info ....... 3-3

System IP Configuration ................................. 3-3

Current Settings ........................................ 3-4

Changing System IP Information .............. 3-4

Bootstrap Configuration .................................. 3-5

Loading Software Locally .......................... 3-7

Loading Software Remotely ...................... 3-7

Current Settings ........................................ 3-9

SNMP Configuration ..................................... 3-11

Page iv

GLXY9.book Page v Thursday, February 17, 2000 3:04 PM

Current Settings ...................................... 3-12

Changing Community Strings ................. 3-12

Enabling Authentication Traps ................ 3-13

Adding or Updating a Trap Receiver ...... 3-13

Deleting a Trap Receiver ........................ 3-13

Port Configuration ........................................ 3-14

Viewing Legends for Configuration Settings 3-16

Current Port Settings .............................. 3-17

Enabling or Disabling a Port ................... 3-17

Configuring Auto-negotiation .................. 3-18

Configuring a Port Manually ................... 3-19

Configuration of 1000BaseX ports ......... 3-20

Enabling or Disabling a Port ................... 3-20

Advanced Port Configuration ....................... 3-22

Advanced 10/100BaseTX Port Configuration 3-22

Current Settings ...................................... 3-22

Setting the Maximum Broadcast or Multicast Rate

3-23

Enabling or Disabling 802.3x Flow Control 3-24

Setting Port Default Priority .................... 3-24

Advanced 1000BaseX Port Configuration 3-26

Global Port Configuration ............................. 3-26

Unicast Forwarding Database Configuration 3-28

Current Settings ...................................... 3-30

Displaying the Forwarding Database ...... 3-30

Searching for a MAC Address ................ 3-36

Setting the MAC Address Age-Out Time 3-37

Image File Downloading Configuration ........ 3-37

Image Downloading Through TFTP ....... 3-38

Serial Downloading Configuration .......... 3-41

System Reset Configuration ........................ 3-44

Current Options ...................................... 3-44

Resetting the IntraChassis 9000 ............ 3-45

Scheduling a Reset ................................ 3-45

Page -v

GLXY9.book Page vi Thursday, February 17, 2000 3:04 PM

Viewing the System Log ............................... 3-46

Clearing the System Log ......................... 3-47

Viewing Current Operating Information ........ 3-48

User Interface Configuration ........................ 3-50

Current Settings ...................................... 3-50

Setting Console Idle Time-out Period ..... 3-51

Setting Telnet Idle Time-out Period ........ 3-51

Changing the Password .......................... 3-52

..................................................................... 3-52

4 Statistics ........................................................... 4-1

Viewing Statistics ........................................... 4-1

5 Advanced Management .................................... 5-1

Spanning Tree Protocol .................................. 5-1

Overview ................................................... 5-1

How It Works ............................................. 5-2

Enabling and Disabling STP ..................... 5-2

Configuring Spanning Tree Parameters ... 5-2

Current STP Settings ................................ 5-5

Spanning Tree Port Configuration ............ 5-5

Setting Port Priority and Path Cost ........... 5-6

SNMP and RMON Management .................... 5-7

RMON Management ................................. 5-7

Security .......................................................... 5-8

Enabling and Disabling Duplicated-IP Detection 5-

10

Enabling and Disabling Duplicated-IP Trap 5-10

Enabling and Disabling Station Movement Trap 5-

10

Viewing a List of Duplicated-IP Addresses 5-11

Resetting Security to Defaults ................. 5-11

VLAN Management ...................................... 5-11

Page vi

GLXY9.book Page vii Thursday, February 17, 2000 3:04 PM

VLAN Specifications for the IntraChassis 9000 5-

12

Other VLAN Features in IntraChassis 9000 5-14

Abbreviations .......................................... 5-14

Default VLAN .......................................... 5-15

Port VLAN ID .......................................... 5-15

Port Admit Frame Type .......................... 5-16

Port Ingress Filtering .............................. 5-16

VLAN Port Membership and Untagging . 5-16

6 Web Browser Management .............................. 6-1

Accessing with a Web Browser ...................... 6-1

Management Buttons ..................................... 6-2

Front Panel Button ......................................... 6-3

Genl Info (General Information) Button .......... 6-5

Statistics Button ............................................. 6-6

Port Config (Port Configuration) Button ......... 6-9

Span Tree (Spanning Tree) Button .............. 6-10

SNMP Button ............................................... 6-11

Addr (Address) Table Button ....................... 6-12

VLAN Button ................................................ 6-13

Duplicate IP Button ...................................... 6-17

Contacting Technical Support .................. A-1

MIB Object Definitions for Counters ......... B-1

App. A Technical Support .................................. A-1

App. B MIB Statistics .......................................... B-1

Page -vii

GLXY9.book Page viii Thursday, February 17, 2000 3:04 PM

Page viii

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

1

Introduction

This chapter introduces the IntraChassis 9000 architecture, then gives a description of the chassis and the various modules that can be installed in it.

There are also tables of the key features, default settings, and specifications of the IntraChassis 9000, and explanations of the different LED indicators used by the various modules.

IntraCore Architecture Overview

Asanté has developed the IntraCore™ Architecture to meet the needs of multiservice networks that support all applications and data types. The architecture is standards-based and provides

❑ multi-vendor inter operability a migration path from current systems investment protection

With the IntraCore Architecture, Asanté has found innovative ways of embracing industry standards and technology advances to create products capable of meeting real world requirements for converged, multi-service networks.

The overall design incorporates a family of tightly integrated ASICs, designed as system building blocks. These building blocks enable the rapid development of advanced networking systems that are timed to meet market requirements. The architecture ensures consistent high performance as systems scale their capacity and feature capability. This approach extends the useful life of the system and protects customer investments.

The Core Switching Engine

The Core Switching Engine is the centerpiece for all IntraCore products. Based on advanced silicon ASICs, the Core Switching Engine is a high performance, non-blocking, multi-gigabit switching fabric with scalable bandwidth capacity.

The Core Switching Engine is data format independent and can support either frame or cell based interfaces. This capability is becoming increasingly

Page 1-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Introduction important as enterprise (primarily frame-based) and service provider (primarily cell-based) networks move closer together.

Infrastructure Connectivity

The second key element of the architecture is Infrastructure Connectivity.

IntraCore specifies standards based, high performance, cost effective technologies for connectivity among devices in the network.

In the LAN –

At the network edge, Layer 2 switched 10/100/1000 Ethernet meets the requirements for high-speed connectivity of desktop computers and scalable, cost effective data transmission for trunks to the network core.

In the network core, Layer 2/3+-switched 10/100/1000 Ethernet meets the requirements for high speed, scalable, cost effective data transmission and support for all multi-service data types. High performance servers can be centrally located for added physical security.

Throughout the LAN, advanced queuing techniques combined with multiple priority levels and support for industry standard 802.1Q and 802.1p enable

Quality of Service within the network.

In the MAN/WAN –

Long haul Gigabit Ethernet, ATM, and Packet over SONET meet the requirements for all of the following:

❑ scalable, cost effective data transmission support for all multi-service data types service provider inter operability

Network Management, Security, Performance, and

Control

IntraCore includes a rich suite of features required for the effective management, security, performance and control of the network. The following table illustrates the features and standards supported as part of this section of the overall architecture.

Page 1-2

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM

IntraCore Architecture Overview

Feature

Web Browser Management

SNMP, RMON

Standard MIsS

802.1P Priority

802.1Q VLAN Tagging

802.1D – Spanning Tree

IGMP V1, V2 Snooping

RSVP Snooping

GARP Multicast Registration

Duplicate IP addr. detection

Station movement notification

IP to MAC address binding

Controlled management access

GVRP (Group VLAN Registration Protocol)

Advanced Port Configuration: Broadcast & Multicast rate limit & port priority

Policy management: IntServ

(RSVP), DiffServ, COPS

Directory services: DNS,

DHCP, LDAP

Management

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Security

Performance

Control

Supported Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Supported

Table 1-1 Summary of IntraCore’s supported features

Page 1-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

Introduction

The IntraCore Product Family

The Asanté IntraCore architecture is the basis for a family of switching system products in fixed, stackable and chassis form factors that allow customers to integrate telephony, video and data applications. Initially two systems will be offered that provide high performance, high port count Layer 2 switching.

Additional configurations will be introduced to offer advanced Layer 3 and above routing, traffic classification, advanced QoS, higher bandwidth and port capacity. All systems will be consistent in their operation and management allowing customers to seamlessly deploy any model in their network.

Edge Switches

Providing the first point of connectivity to the network are the Edge Switches.

These connect to an Enterprise switch in the network core and provide aggregation of traffic from desktop computers over high capacity trunks. The initial product introduced in the Edge Switch category is the IntraStack 8000.

The IntraStack 8000 is a stackable, high performance solution for enterprise edge applications. Each stack supports up to 192 10/100Mbps switched

Ethernet connections for cost-effective high-density connectivity in wiring closets. The system can operate as a stand-alone network or be used in combination with IntraChassis 9000 in the backbone.

Enterprise Switches

In the network core, Enterprise Switches are deployed to aggregate traffic from wiring closets and provide high-speed connectivity to network servers. Typically these switches are modular in form factor, and can be easily upgraded or reconfigured. This flexibility provides for customized configurations to meet a wide variety of requirements. The initial product introduced in this category is the IntraChassis 9000.

The IntraChassis 9000

The IntraChassis 9000 is a chassis based modular Gigabit Ethernet enterprise switch designed for either high density wiring closets or as the core of the network backbone. The system can support up to 192 10/100Mbps switched

Ethernet or 16 switched Gigabit Ethernet connections. System modules offer choice in media and connector types to best suit existing wiring infrastructure systems.

Page 1-4

GLXY9.book Page 5 Thursday, February 17, 2000 3:04 PM

Modules

Figure 1-1 IntraChassis 9000 Front Panels

Modules

The following modules can be installed in the IntraChassis 9000 chassis.

Network Management Module

This module is included with the IntraChassis 9000 chassis, and provides management for it and all other modules you install. It occupies one slot, and has a single DB-9 port for the console. The module supports Telnet and Web

Page 1-5

GLXY9.book Page 6 Thursday, February 17, 2000 3:04 PM

Introduction

Browser management via industry standard SNMP with support for MIB II,

RMON (four groups), Bridge MIB, and Asanté private MIBs.

Figure 1-2 Management Module

24-port 10/100 Switch Module

This module provides 24 ports supporting switched 100BaseTX or 10BaseT per port. Each module occupies a single slot and has either 24 RJ-45 connectors, or 2 RJ-21 connectors.

Figure 1-3 24-port 10/100 Switch Module

2-port Gigabit Ethernet Switch Module

This module provides slots for two switched Gigabit Ethernet ports. Each module occupies a single slot and has 2 GBIC interfaces, which accept Asanté or third party GBIC interfaces. The following subsections describe the possible

GBIC interfaces.

Figure 1-4 2-port Gigabit Ethernet Switch Module

1000Base SX GBIC

This module provides a GBIC interface with SC-type fiber connectors. The interface supports 62.5 and 50 micron multimode fiber media. The 62.5 micron multimode fiber can be up to 260 meters long, and the 50 micron multimode fiber can be up to 525 meters long.

Page 1-6

GLXY9.book Page 7 Thursday, February 17, 2000 3:04 PM

Modules

1000BaseLX Long Haul GBIC

This module provides a GBIC interface for SC-type fiber connectors. The interface supports 10 micron single mode fiber for distances up to 100 kilometers.

1000BaseLX GBIC

This module provides a GBIC interface for SC-type fiber connectors. The interface supports 10 micron single mode fiber for distances up to 3 kilometers.

Power Supply

One Power Supply is provided with the IntraChassis 9000. A second Power

Supply can be added to provide additional power and redundancy for the other modules.

Figure 1-5 Power Supply

Page 1-7

GLXY9.book Page 8 Thursday, February 17, 2000 3:04 PM

Introduction

Features

The following table lists the major features of the IntraChassis 9000 switch.

Feature Description

Media Flexibility

High Density

Expansion module options include 24-port 10/100 Base-TX switched Ethernet modules, 2-port Gigabit Ethernet modules with GBIC slots, and 24-port 10/100 Base-TX switched Ethernet

RJ-21 modules for compatibility with existing wiring.

Supports up to 192 10/100 switched Ethernet ports or up to 16 switched Gigabit Ethernet ports in a single chassis. This saves space in crowded equipment rooms.

ASIC-Based Architecture ASIC-based packet processing provides wire speed performance on all interfaces.

High Performance

16Gbps Backplane

The system supports current requirements for multi-service voice, video, and data applications with bandwidth to spare. The highcapacity backplane is designed so that it may be scaled up to

128Gbps, extending the useful life of the chassis.

Multiple Priority Queues The “application aware” system ensures that mission critical applications get the bandwidth and priority they need, even under heavy traffic conditions. Low latency requirements are managed by the system when network congestion occurs.

Chassis Based Form Factor

The nine slot modular chassis allows configuration flexibility and cost effective network expansion. A wide variety of switched 10/

100/1000 Ethernet interfaces are supported, with flexible media options to meet all network requirements. The IntraChassis 9000 can be configured as a high-density switch for campus wiring closets, or a high-capacity switch for Gigabit Ethernet backbones.

Configuration Flexibility and Growth

GBIC Modules for Gigabit Ethernet Media Flexibility

Expansion modules can be mixed and matched in any configuration and quantity to meet design requirements. You can add capacity only when your business requires it.

The two GBIC Gigabit Ethernet modules can be configured with any combination of 1000SX, 1000LX or 1000LX (Long Haul)

GBIC interfaces. Either Asanté or third party GBIC interfaces can be used, and the interfaces can be “hot swapped.” This means that

GBIC interfaces can be re-deployed if equipment is retired.

Page 1-8

GLXY9.book Page 9 Thursday, February 17, 2000 3:04 PM

Features

Feature (Cont.) Definition (Continued)

Reliability and Redundancy

For maximum uptime and minimum network disruption, the interface and management modules are hot-swappable. Configuration options include support for up to two load-sharing, hotswappable power supplies.

The system can be rack-mounted to save space.

Installation Options

Security

Web Based Management Built-in Web-based interface is provided for chassis management, module management, port-level control, and monitoring. The

IntraChassis 9000 can also be managed via Telnet, Console, or third party SNMP console.

VLANs

Node summary tracks MAC and IP addresses per device, for multiple devices on each port. The New Node Detection feature provides per-port security, allowing the network manager to specify which MAC is authorized on each port. Only the device with that

MAC address is allowed to connect to that specific port.

Supports up to 64 port-based VLANs (IEEE 802.1Q compliant) for security, logical network design, and the control of broadcast traffic. The 802.1Q standard specifies VLAN tagging for trunking

VLANs from switch to switch, or switch to router. Compatible with all 802.1Q equipment for easy integration into existing networks.

Multicast Control

RMON

Spanning Tree Protocol

Y2K compliance

The IntraChassis 9000 supports standards based IGMP snooping and GMRP for control of multicast traffic generated by bandwidth-hungry applications like video, ensuring maximum application and network performance.

The administrator can use a RMON probe for in-depth traffic analysis, with support for four groups of RMON.

Spanning Tree Protocol (STP) detects and eliminates data loops to prevent broadcast storms from overwhelming your network.

All IntraChassis 9000 modules are Y2K compliant.

Table 1-2 IntraChassis 9000 Features

Page 1-9

GLXY9.book Page 10 Thursday, February 17, 2000 3:04 PM

Introduction

Defaults and Specifications

The IntraChassis 9000 is shipped with the following factory default settings and specifications:

Configuration

Backplane Speed

Switching Method

Forwarding Rates:

(64 byte packets)

Buffer Size

MAC Address Table

Full-Duplex

VLAN

Spanning Tree Protocol

Flood Rate Limiting

Priority

RMON

SNMP

Console Baud Rate

Password

Power Requirements

Environmental Operating Range

Default Setting

32Gbps.

Store-and-forward

Switched 10Mbps = 14,880 pps

Switched 100Mbps = 148,810 pps

Switched 1000Mbps = 1,488,100 pps

4MB

8K

Standards based Auto-negotiation enabled

64 port based VLANs, GVRP support, 802.1Q VLAN Tagging

802.1D, enabled

Broadcast traffic

802.1Q, 8 levels mapped to 4 Queues

Groups 1-3, 9

MIB-II, Bridge MIB, RMON MIB, Asanté private MIBs

9600

Asanté

90 - 224 V, 50 - 60 Hz

Temperature: 0° - 45° C (Storage: -40° - 85° C)

Relative Humidity: 5% - 95% non-condensing

Table 1-3 Defaults and Specifications

Page 1-10

GLXY9.book Page 11 Thursday, February 17, 2000 3:04 PM

LEDs

LEDs

The following indicator lights are used on the various modules of the

IntraChassis 9000.

LED

Management Module

Power

Slot Control Center

Color and Meaning

Green - Power is on when lit

Green - upper row - For future functionality

Green - lower row - Module is installed in this slot.

Gigabit Switch (GBIC)

Power

Link

24-port 10/100 Switch

Link/Speed

Duplex/Activity

Power Module

Power

P-Fail

Fail

Green - Power is on when lit

Green - connection and link has been made.

Green - Link at 100Mbps Amber - Link at 10Mbps

Green -Full Duplex Amber - Half Duplex Blinking - Active

Green - Power is available to IntraChassis 9000

Amber - Power is not available to module

Amber - Power module is not delivering power

Table 1-4 LEDs and their meanings

Page 1-11

GLXY9.book Page 12 Thursday, February 17, 2000 3:04 PM

Introduction

Page 1-12

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

2

Installation and Set-up

This chapter explains how to install, connect, and configure the IntraChassis

9000 chassis and modules to work with your network. It also explains how to set up your IntraChassis 9000 for management, either from a console, via telnet, via SNMP, or by using a Web browser.

Installation Guidelines

The following guidelines will help you prepare to install your IntraChassis 9000 in such a way that it has the proper power supply and environment.

Safety Information

The following sections provide guidelines and procedures to help you install and use the IntraChassis 9000 safely.

Safety First

Use the following guidelines to ensure your safety and protect the equipment.

This list is not inclusive of all potentially hazardous situations that you may be exposed to as you install the switch, so be alert .

❑ Never try to lift an IntraChassis 9000 chassis by yourself; two people are required to lift these switches.

Always unplug all power cords before installing or removing a chassis or removing the chassis front panel.

❑ Keep the chassis area clear and free of dust during and after installation.

❑ Keep tools and chassis components off the floor and away from foot traffic.

❑ Avoid wearing jewelry (including rings and chains) or other items that could get caught in the chassis. Avoid wearing any loose clothing or securely fasten items such as ties, scarves, or sleeves.

❑ Install the system in compliance with the following local and national electrical codes:

Page 2-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

❑ United States—National Fire Protection Association

(NFPA 70); United States National Electrical Code

Canada—Canadian Electrical Code, Part I, CSA C22.1

Other countries—International Electrotechnical Commission (IEC) 364, Part 1 through Part 7

Important: Take the following precautions when installing the IntraChassis 9000:

Only trained and qualified personnel should be allowed to install or replace this equipment.

This equipment is to be installed and maintained by service personnel only as defined by AS/NZS 3260 Clause 1.2.14.3

Service Personnel.

Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.

Unplug the power cord before you work on a system that does not have an on/off switch.

Before installing the IntraChassis 9000, unplug the power cord.

Do not work on the system or connect or disconnect cables during periods of lightning activity.

Do not touch the power supply when the power cord is connected. Line voltages are present within the power supply when the power cord is connected.

Read the installation instructions before you connect the system to its power source.

This unit might have more than one power cord. To reduce the risk of electric shock, disconnect the two power supply cords before servicing the unit.

Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury and equipment damage.

Page 2-2

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM

Installation Guidelines

Lifting the Chassis Safely

The IntraChassis 9000 is not intended to be moved frequently. Before you install the switch, ensure that your site is properly prepared so that you can avoid moving the chassis later to accommodate power sources and network connections.

Two people are required to lift the IntraChassis 9000. Whenever you lift the chassis or any heavy object, follow these guidelines:

Never attempt to lift a chassis by yourself. The size and weight of a chassis requires two people to safely lift and move it without causing injury or damaging the equipment.

Ensure that your footing is solid, and balance the weight of the chassis between your feet.

❑ Lift the IntraChassis 9000 slowly; never move suddenly or twist your body as you lift.

❑ Keep your back straight and lift with your legs, not your back. If you must bend down to lift the chassis, bend at the knees, not at the waist, to reduce the strain on your lower back muscles.

❑ Leave all switch and power modules in place once they are properly installed.

❑ Always disconnect all external cables before lifting or moving the chassis.

Safety With Electricity

The secondary power supply is designed to be removed and replaced while the system is operating without presenting an electrical hazard or damage to the system. Before removing a redundant power supply, ensure that the other power supply is turned on.

Follow these basic guidelines when working with any electrical equipment:

Before beginning any procedures requiring access to the chassis interior, locate the emergency power-off switch for the room in which you are working.

Disconnect all power and external cables before installing or removing a chassis.

❑ Do not work alone when potentially hazardous conditions exist.

Never assume that power has been disconnected from a circuit;

Page 2-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

Installation and Set-up always check.

❑ Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

❑ Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds.

❑ Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

❑ Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

Power Requirements

The source electrical outlet should be installed near the IntraChassis 9000 and easily accessible. It must also be properly grounded.

Make sure the power source adheres to the following guidelines:

❑ Voltage range: 100 to 240 VAC

Frequency range: 60/50 Hz

❑ Maximum current: 10 A per power supply at 110 volts

Environmental Requirements

The IntraChassis 9000 must be installed in a clean, dry, dust-free area with adequate air circulation to maintain the following environmental limits:

❑ Temperature: 0° to 40° C (32° to 104° F)104°

❑ Relative Humidity: 5% to 85% non-condensing

Avoid direct sunlight, heat sources, or areas with high levels of electromagnetic interference.

Cooling and Airflow

Do not restrict air flow by covering or obstructing air vents on the sides of the chassis.

Page 2-4

GLXY9.book Page 5 Thursday, February 17, 2000 3:04 PM

Installation Overview

Installation Overview

The table below describes the steps needed to install the IntraChassis 9000. The steps that are optional are labeled “optional” and the steps that are required are labeled “required.” The sections that follow explain each step in detail.

1

(Required)

2

3

Step

(Required)

(Required)

4

(Optional)

5

(Required)

6

(Required)

7

(Required)

Action to Be Taken

Open the box and check the contents.

See the Package Contents sheet for a complete list of the items included with your IntraChassis 9000.

Install the IntraChassis 9000 chassis in an equipment rack or wall

rack, or prepare it for desktop placement. See page 2-5.

Important! When fully loaded, the IntraChassis 9000 can weigh over 100 lbs (45 Kg). Use proper lifting equipment and techniques to prevent back and other injuries.

Install the modules you have purchased for your IntraChassis 9000

and ensure each is properly seated and locked in place. See page 2-9.

Install a second power supply module and make sure it is properly

seated in the chassis. See page 2-11.

Connect the power supply or power supplies.

See page 2-11.

Connect the modules to your network cables. See page 2-12.

Configure the IntraChassis 9000 for management capabilities.

See page 2-13.

Table 2-1 Installation Overview

Rack Mounting/Desktop Placement

The IntraChassis 9000 chassis can be installed in a standard 19-inch equipment rack. It can also be placed on a stable horizontal surface with support capabilities of 150 pounds (68.2 kilograms).

Important: The equipment rack or desk on which you install your IntraChassis 9000 must be secure and stable.

Equipment racks must be fastened to the floor; desks must be resting on a flat, stable surface.

Page 2-5

GLXY9.book Page 6 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

Equipment Rack Installation of the Chassis

To install the unit in an equipment rack, use the following procedure. Refer to

Figure 2-1 below.

Safety Precautions for Rack Installation

Important! Disconnect all cables from the IntraChassis

9000 before continuing. Also, do not install the modules you have purchased until the chassis has been installed in the rack. This will reduce the weight of the chassis during rack installation.

Important! Before installing the chassis in a rack, read the

“Safety Information” section earlier in this chapter to famil-

iarize yourself with the proper site and environmental conditions. Failure to read and follow these guidelines could lead to an unsuccessful installation and possible damage to the system and components.

Important! To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

❑ This unit should be mounted at the bottom of the rack if it is the only unit in the rack.

❑ When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.

Rack Guidelines

Size

Guideline

Stability

Specification

Width; 17.75 inches (45.09 cm).

Depth: 19.25 inches (48.9 cm) to 32 inches (81.3 cm).

Rack must be bolted to the floor. Mount heavier units at the bottom of the rack, and mount the IntraChassis 9000 at the bottom of the rack if it is the only unit mounted; this will ensure that the rack does not become top-heavy. If the rack has stabilizing devices, make sure they are installed before mounting the IntraChassis 9000.

Page 2-6

GLXY9.book Page 7 Thursday, February 17, 2000 3:04 PM

Rack Mounting/Desktop Placement

Guideline

Ventilation

Clearance

Specification

Ensure that the rack is installed in a room where the temperature remains below 40 ° C ( 104° F) . Ensure also that there are no obstructions, such as other equipment or cables, blocking airflow to or from the IntraChassis 9000 vents.

In addition to providing clearance for ventilation, ensure that there is adequate clearance for servicing the modules of the IntraChassis 9000 from the front.

Figure 2-1 Mounting rack bracket on the IntraChassis 9000 chassis

1

Place the IntraChassis 9000 chassis on a flat, stable surface.

2

Locate a rack-mounting bracket (supplied) and place it over the mounting holes on one side of the unit.

3

Insert five screws (supplied) into the holes and tighten with a Phillips screwdriver. Do not use less than six screws for this mounting.

4

Repeat the two previous steps for the unit’s other side.

Page 2-7

GLXY9.book Page 8 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

5

Place the unit in the equipment rack.

Important! When fully loaded, the IntraChassis 9000 can weigh over 100 lbs. Use proper lifting equipment

and techniques, as described in “Lifting the Chassis

Safely” earlier in this chapter, to prevent back and other

injuries.

6

Secure the unit by screwing its mounting brackets to the equipment rack. Use a minimum of six {right?} screws for this purpose.

Important! Make sure the unit is supported until all the mounting screws for each bracket are secured to the equipment rack. Failure to do so could cause the unit to fall, resulting in personal injury or damage to the unit, or both.

7

Proceed to the “Cable Guide Installation” section.

Free-Standing/Desktop Installation of the Chassis

The IntraChassis 9000 chassis has four rubber feet on the bottom of the chassis that allow for free-standing installation of the unit.

For free-standing/desktop placement:

1

Attach the four rubber pads (supplied) to the bottom of each corner of the IntraChassis 9000 chassis.

2

Place the unit on a flat surface with a minimum area of

17.1” x 13.5” (434.3 mm x 342.9 mm) and support capacity of 150 lbs (68.2 kg).

3

Make sure there is enough ventilation space between the

IntraChassis 9000 and surrounding objects.

4

Proceed to “Cable Guide Installation” below.

Cable Guide Installation

Before installing any of the modules in your IntraChassis 9000, place the cable guide hook units on each side of the front panel and attach them with the screws provided. Make sure you install the guides in such a way that the hooks open upward.

Page 2-8

GLXY9.book Page 9 Thursday, February 17, 2000 3:04 PM

Installing Modules

Installing Modules

Up to eight IntraChassis modules can be installed in the IntraChassis 9000 chassis, in addition to the Management Engine module, which is pre-installed in the factory.

Before installing any modules, make sure the cable guides have been installed, as explained in the previous section of this chapter.

To install any combination of 2-port Gigabit Ethernet Switch (GBIC) modules and 24-port 10/100 Switch modules, use the following procedure.

Important: Make sure the IntraChassis 9000 chassis is properly installed in an equipment rack or resting on a flat, stable surface capable of supporting 150 pounds (68.2kg).

Also make sure the power cord for the power module is disconnected for initial installation.

1

Pull the small ejector lever on each end of the module’s face plate out, away from the face plate.

2

Align the bottom of the module with the rails on the inside of the chassis slot where you want to install the module, as

shown in Figure 2-2.

3

Slide the module into the slot until it stops, then push the module in gently until it seats with the connector.

Page 2-9

GLXY9.book Page 10 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

Advanced Systems

Galaxy 9000 GigaSwitch IntraChassis 9000

Management Engine

Power

Mode Set

2 4 6 8

IntraChassis 9000

24-port 10/100 Switch Blade

Power

2 4 6 8 10 12 14 16 18 20 22 24

1 3 5 7 9 11 13 15 17 19 21 23

Link/Speed

Duplex/Act

Link/Speed

Duplex/Act

1 3 5 7

10 12 14

16

9 11 13 15

18 20 22 24

17 19 21 23

2 4 6 8

IntraChassis 9000

24-port 10/100 Switch Blade

Power

2 4 6 8 10 12 14 16 18 20 22 24

1 3 5 7 9 11 13 15 17 19 21 23

Link/Speed

Duplex/Act

Link/Speed

Duplex/Act

1 3 5 7

2 4 6 8

IntraChassis 9000

24-port 10/100 Switch Blade

Power

2 4 6 8 10 12 14 16 18 20 22 24

Link/Speed

Duplex/Act

Link/Speed

Duplex/Act

1 3 5 7 9 11 13 15 17 19 21 23

1 3 5 7

10 12 14 16

9 11 13 15

10 12 14

16

9 11 13 15

18 20 22 24

17 19 21 23

18 20 22 24

17 19 21 23

!

Power

P-Fail

Fail

CM

Figure 2-2 Installing module and power supply

4

Press both ejector levers in, toward the module’s face plate, simultaneously. This will lock the module in place and insure proper contact of all connecting surfaces.

5

Tighten the thumbscrews at the ends of the module’s face plate, next to the ejector levers. Use a straight-bladed screwdriver, so the thumbscrews cannot be loosened by hand.

Installation of the module is complete. Repeat this procedure for each module

you have purchased, then proceed to “Connecting Power”.

Important: Modules are not to be removed from the Intra-

Chassis 9000 except by a qualified System Administrator.

Page 2-10

GLXY9.book Page 11 Thursday, February 17, 2000 3:04 PM

Installing Second Power Supply

Installing GBIC Interfaces

If you have installed modules for GBIC interfaces, install each interface itself by sliding it into the port, until the locking tabs on either side of the GBIC interface unit click into the locked position. You can then connect the SC-type fiber media.

To remove a GBIC interface, squeeze the locking tabs against the sides of the unit until they release it, then slide the interface out of the port.

Installing Second Power Supply

To install a power supply module in your IntraChassis 9000, first loosen and undo the thumbscrew holding the cover plate, then remove the plate and slide

the second power supply into the chassis from the front, as shown in Figure 2-2.

Tighten the thumbscrew to hold the power supply firmly in place.

Connecting Power

To connect power to the IntraChassis 9000, use the following procedure.

Important: Carefully review the power requirements on

page 2-4 before connecting power to the IntraChassis 9000.

1

If you have purchased a second power supply, insert it in the bay provided at the bottom of the IntraChassis 9000 chas-

sis, as shown in Figure 2-2.

2

Plug one end of the supplied power cord into the power connector on the back of the unit.

3

Plug the other end into a grounded AC outlet.

Important: If the power does not come on, refer to

Appendix A, “Troubleshooting.”

The IntraChassis 9000 is ready for connection to the network.

Page 2-11

GLXY9.book Page 12 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

Connecting to the Network

The IntraChassis 9000 unit may be connected to an Ethernet network, with the unit powered either on or off. Use the following procedure to make your network connections.

1

Connect network devices to the IntraChassis 9000, following the cable guidelines outlined below.

2

Route the cables through the cable supports at the ends of each module, to keep cables from the different modules from interfering with each other.

3

After the unit is connected to the network, it can be config-

ured for management capabilities. See “Configuring for

Management” later in this chapter.

10/100BaseX Ports Cabling Procedures

The 24 fixed ports on each 10/100 module allow for the connection of 10Base-

T or 100Base-TX network devices. The ports are compatible with IEEE 802.3 and 802.3u standards.

Important: The IntraChassis 9000 must be located within 100 meters of its attached 10Base-T or 100Base-TX devices.

Connecting To

Network Station

Repeater/Hub

Repeater/Hub’s Uplink port

Cable Required

Category 5 UTP (Unshielded Twisted-Pair) straight-through cable

(100 meters maximum) with RJ-45 connectors.

Category 5, UTP cross-over cable (100 meters maximum) with RJ-

45 connectors.

Category 5, UTP straight-through cable (100 meters maximum) with RJ-45 connectors.

Table 2-2 10/100BaseTX cabling requirements

Page 2-12

GLXY9.book Page 13 Thursday, February 17, 2000 3:04 PM

Configuring for Management

1000BaseX Ports Cabling Procedures

Cabling requirements for the 2-port Gigabit Ethernet modules depend on which type of GBIC interface has been installed. Use the following chart to determine the cabling requirements for your GBIC.

Connecting To

1000BaseSX GBIC

1000BaseLX Long

Haul GBIC

1000BaseLX GBIC

Cable Required

Cables with SC-type fiber connectors: 62.5 micron multimode fiber media up to 260 meters long, or 50 micron multimode fiber media up to 525 meters long.

Cables with SC-type fiber connectors: 10 micron single mode fiber media up to 100 kilometers long.

Cables with SC-type fiber connectors: 10 micron single mode fiber media up to 3 kilometers long.

Table 2-3 1000BaseX cabling requirements

Configuring for Management

To use the IntraChassis 9000 as a managed switch, it must be configured with an IP address. This can be accomplished in one of two ways:

❑ automatically using BootP (default)

❑ manually via the unit’s Console port

Page 2-13

GLXY9.book Page 14 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

BootP Configuration

The IntraChassis 9000 is shipped with BootP support. BootP allows the

IntraChassis 9000 to be automatically configured with an IP address when it is connected to the network and is powered on, if your network contains a BootP server configured with available, valid IP addresses. Use the following procedure to set up BootP.

Important: BootP configuration only works if the

IntraChassis 9000 does not have an IP address assigned to it.

1

Make sure your network has a BootP server configured with a valid IP address entry for the IntraChassis 9000.

2

When the IntraChassis 9000 is connected to the network and is powered on, it automatically transmits a BootP request across the network (up to 10 times) until it receives a valid IP address from the BootP server.

3

After an IP address is received, the IntraChassis 9000 can be

managed via in-band access. See Chapter 3, “Basic Configuration” for more information.

To verify that a valid IP address was received, try to ‘ping’ the IntraChassis

9000; if you can access the IntraChassis 9000, it is properly configured with an

IP address.

See “Bootstrap Configuration” in Chapter 3 for more information on using

BootP.

Page 2-14

GLXY9.book Page 15 Thursday, February 17, 2000 3:04 PM

Configuring for Management

Connecting To a Console

Use the following procedure to make the cable connection from a terminal to the console port on the Management Engine of the IntraChassis 9000.

1

Using a straight-through RS-232 cable with a 9-pin male

D-subminiature plug at one end, connect a terminal or workstation (PC or Macintosh) running a terminal emulator to the Console port on the front of the IntraChassis

9000.

2

Make sure both units are powered on.

If using a PC with a terminal emulator, make sure it is configured with the following terminal settings:

❑ Baud: 9600

❑ Data Bits: 8

❑ Parity: None

❑ Stop Bits: 1

❑ Flow Control: None

3

Once connected, the Local Management Main Menu appears on the terminal screen.

For further information on setting an IP address for configuration of a terminal, or a PC running a VT100 terminal or emulator (such as HyperTerminal,

ProComm, or ZTerm), see “System IP Configuration” in Chapter 3.

Page 2-15

GLXY9.book Page 16 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

Management Options

The IntraChassis 9000 can be managed using any of the following methods:

Method Type Description

Console

Telnet

(four sessions maximum)

HTTP Server

Out-of-band management

In-band management

In-band management

SNMP-Based Network

Management Software

In-band management

Local connection to the IntraChassis 9000 via the

Console port

Remote connection over the network to the

IntraChassis 9000 via Telnet session

Remote connection to the IntraChassis 9000 via a Web browser

Remote connection to the IntraChassis 9000 via any SNMP-based network management application

Table 2-4 Management Methods

The remaining sections of this chapter describe how to connect to the

IntraChassis 9000 using either out-of-band or in-band management.

Out-of-Band Management

Out-of-band network management allows you to configure, manage, and monitor the IntraChassis 9000 and all of the installed modules. You can perform these functions by attaching a terminal (or a terminal emulator) to the

Console port on the management engine and using the menu-driven Local

Management Interface.

Out-of-band network management is guaranteed even when the in-band

Ethernet network is down.

To access the IntraChassis 9000 Local Management Interface using out-of-band

management, first follow the procedure in “Connecting To a Console” and then

go on to the “Management Interface” section, later in this chapter.

Page 2-16

GLXY9.book Page 17 Thursday, February 17, 2000 3:04 PM

Management Options

In-Band Management

In-band network management allows you to manage, control, and monitor the

IntraChassis 9000 over the Ethernet network.

You can perform these functions by accessing the IntraChassis 9000 via any of the following methods:

❑ By connecting with a Telnet program and using the Local Manage-

ment Interface.

By connecting with any World Wide Web browser, and using the

Web Management Interface.

❑ By connecting with any SNMP-based network management application and using its interface.

To manage the IntraChassis 9000 via in-band management, use the following procedure.

1

Make sure the network to which the IntraChassis 9000 is connected is functioning.

2

Make sure the IntraChassis 9000 is configured with valid IP information.

See “Configuring for Management” earlier in this chapter.

3

Connect to the IntraChassis 9000 via Telnet, with a Web browser, or with any SNMP-based network management application.

Telnet

Use a network connection to any PC and enter the telnet command to access the IntraChassis 9000. The Main Menu of the Management Interface

will appear. Go on to the “Management Interface” section below.

Note: Almost all management screens using a Telnet connection are identical to those of the out-of-band Console

Interface. On the Main Menu, however, there will be a q option for closing the connection to the IntraChassis 9000.

Web Browser

Refer to Chapter 6, “Web Browser Management”, for information on managing

the IntraChassis 9000 with a Web browser.

Page 2-17

GLXY9.book Page 18 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

SNMP-Based Management

Refer to Chapter 5, “Advanced Management” and your SNMP Software

Manual for information on managing the IntraChassis 9000 with SNMP-based management software.

The Asanté private MIB for the IntraChassis 9000 is available from the Asanté ftp site, ftp.asante.com, or you can copy it from the Installation CD-ROM.

Access to Remote Network Monitoring (RMON) features is available only by

using an SNMP manager. See “SNMP and RMON Management” in Chapter 5

for details.

Management Interface

After you connect to the Local Management Interface using either an out-ofband Console connection or an in-band Telnet connection as described in

“Configuring for Management”, the Main Menu appears, as in Figure 2-3.

=================================================================

IntraChassis 9000 Local Management System Version 1.000

Compiled Date: May 7 1999 15:33:24

Asante Technologies, Inc.

Copyright (c) 1999 Asante Technologies, Inc.

=================================================================

Main Menu

<Cmd>

g

c

s

Command>

<Description>

General Information

Configuration

Statistics

Figure 2-3 Local Management Main menu

From the Main Menu, you can access three submenus:

General Information — 2-19

Configuration — 2-20

Statistics — 4-1

If you are using Telnet, a fourth option, for closing the connection, will also be available.

Page 2-18

GLXY9.book Page 19 Thursday, February 17, 2000 3:04 PM

General Information Screen

Accessing a Submenu

To access a submenu, type the command letter of the corresponding option

(e.g., type g for General Information).

Exiting a Submenu

To exit a submenu, type q. To exit a command line without changing the configuration setting (e.g., the “Set Password” option in the User Interface

Configuration Menu), press ctrl-c.

General Information Screen

The General Information Screen displays the current operating information of the IntraChassis 9000, such as its name, IP address, and boot information.

Note: The information displayed on this screen is read-only.

Accessing General Information

To view General Information for your IntraChassis 9000, type g in the Local

Management Main menu. A screen similar to Figure 2-4 appears.

IntraChassis 9000 General Information

System up for: 000days, 21hrs, 45mins, 45secs

Software Version

Bank 1 Image Version/Date: 1.10/Dec 7 1999 12:14:38 (Running)

Bank 2 Image Version/Date: 1.10/Dec 7 1999 11:54:14

System Information

Prom Image Ver/Date:

DRAM Size: 4MB

1.01/Sep 8 1999 15:59:14

Flash Size: 2.0MB

EEPROM Size: 32KB

Administration Information

Console Baud Rate:

System Name: Asante IntraChassis Switch

System Location: ZLabs Head Office

9600 bps

System Contact: CLB

System MAC Address, IP Address, Subnet Mask and Router

MAC Address:

IP Address:

00:00:94:8E:F3:7B

192.168.54.240

Subnet Mask:

Router:

255.255.255.0

192.168.54.2

Bootstrap Configuration

Boot Load Mode: LOCAL

Press any key to continue...

Figure 2-4 General Information Screen

Page 2-19

GLXY9.book Page 20 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

Note: For a description of each parameter on the General

Information Screen, see “Viewing Current Operating Infor-

mation” on page 3-48.

To exit the General Information Screen, press any key on your keyboard.

Configuration Menu

The Configuration Menu allows you to manage and configure the IntraChassis

9000 and each of its ports.

Logging into the Configuration Menu

1

Type c from the Local Management Interface Main Menu.

2

Enter your password at the “Enter Password” prompt, then press Return.

Important: The default password is Asante. The password is case-sensitive; enter it exactly as shown. For

information on changing the password, see “Changing the Password” in Chapter 3.

The Configuration Menu appears, as shown in Figure 2-5.

IntraChassis 9000 Configuration Menu

r

l

u

s

t

v

q

<Cmd>

a

i

b

n

p

d

f

<Description>

System Administration Configuration

System IP Configuration

Bootstrap Configuration

SNMP Configuration

Port Configuration

Unicast Forwarding Database Configuration

File Downloading Configuration

System Reset Options

System Log

User Interface Configuration

Spanning Tree Configuration

Security Management

VLAN Management

Return to previous Menu

Command>

Figure 2-5 Configuration Menu

Page 2-20

GLXY9.book Page 21 Thursday, February 17, 2000 3:04 PM

Configuration Menu

3

Type the command letter of the configuration option you need to use. For example, type a for the System Administration Configuration menu.

Configuration Menu Options

Table 2-5 on the next page describes each of the options in the Configuration

menu.

Menu Item Description

System Administration Configuration

System IP Configuration

Bootstrap Configuration

Displays and allows you to change the name, location, and contact

information for the IntraChassis 9000. See page 3-2.

Displays and allows changing the IP Address of the IntraChassis

9000. This address is for network access to the switch. See page 3-3.

Allows you to change boot bank and method for loading switch soft-

ware, or change downloading parameters. See page 3-5.

SNMP Configuration

Displays and allows you to change the SNMP (Simple Network

Management Protocol) parameters of the IntraChassis 9000; such as

read/write community strings. See page 3-11.

Port Configuration Allows you to configure manually each of the switch’s ports for speed, connection, link mode, and auto-negotiation. Also displays overall

port status. See page 3-14.

Unicast Forwarding Database Configuration

Allows you to display all of the forwarding database, or display it by port or VLAN, either with or without showing IP addresses. Also lets you search for MAC or IP addresses and lets you set the age-out time

for MAC addresses. See page 3-28.

Allows you to download an Image file for the purpose of upgrading

the IntraChassis 9000 software. See page 3-37.

Image File Downloading Configuration

System Reset Configuration

System Log

User Interface

Configuration

Allows you to reset the switch by a “warm” reboot, or arrange for an

automatic reset (up to 24 hours) in advance. See page 3-44.

Allows you to view a record of any major system events or errors that

have occurred on the IntraChassis 9000. See page 3-46

Allows you to set the idle time-out period and password when using

Console or Telnet access. See page 3-50.

Page 2-21

GLXY9.book Page 22 Thursday, February 17, 2000 3:04 PM

Installation and Set-up

Menu Item

Spanning Tree

Configuration

Security Management

VLAN Management

Return to Previous

Menu

Description

Displays and allows you to change Spanning Tree parameters, to

make sure you prevent loops in network paths. See page 5-2.

Allows you to use various features such as Duplicate IP traps, for port

security. See page 5-8.

Allows you to set up virtual networks. See page 5-11

Allows you to Exit the Configuration menu to the Local Management Interface menu.

Table 2-5 Configuration Menu Options

The first ten options for configuration are described in detail in Chapter 3,

“Basic Configuration” and the more advanced options are discussed in Chapter

5, the “Advanced Management” chapter.

Page 2-22

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

3

Basic Configuration

This chapter describes how to manage the IntraChassis 9000 using the out-ofband Console or in-band Telnet interface.

This chapter contains the following sections:

Overview

❑ System Administration Configuration

System IP Configuration

❑ Bootstrap Configuration

SNMP Configuration

❑ Port Configuration

❑ Advanced Port Configuration

❑ Global Port Configuration

Unicast Forwarding Database Configuration

❑ Image File Downloading Configuration

System Reset Configuration

❑ Viewing the System Log

Viewing Current Operating Information

❑ User Interface Configuration

Basic Configuration Overview

The IntraChassis 9000 Local Management Interface is a menu-driven application which provides management and configuration support for the

IntraChassis 9000 and each of the ports in its different modules.

The Local Management Interface can be accessed via two methods:

❑ Out-of-band connection to the Console port

❑ In-band connection via Telnet (four sessions maximum).

Page 3-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Basic Configuration

For details on accessing the Local Management Interface, see Chapter 2,

“Installation and Set-up”.

System Administration Configuration

This menu displays and allows you to change the IntraChassis 9000’s name, location, and contact information.

To access the System Administration Configuration Menu, type a in the

Configuration Menu. A screen similar to Figure 3-1 appears.

IntraChassis 9000 System Admin. Configuration Menu

System Name: Asante IntraChassis Switch

System Location: ZLabs Main Office

System Contact: CLB

<Cmd>

n

l

c

q

Command>

<Description>

Set System Name

Set System Location

Set System Contact Information

Return to Previous Menu

Figure 3-1 System Administration Configuration Menu

Current Settings

The following table describes each setting on the System Administration

Configuration Menu.

Setting

System Name

System Location

System Contact

Description

The name of the IntraChassis 9000 (up to 64 characters, including spaces).

Place where you have installed the IntraChassis 9000 (up to 64 characters, including spaces).

The name of the person or entity responsible for the IntraChassis

9000 (up to 64 characters, including spaces).

Table 3-1 System Administration settings

Page 3-2

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM

System IP Configuration

Changing System Administration Info

To change the name, location, or contact information for the IntraChassis

9000, use the following procedure.

1

Open the System Administration Configuration Menu by typing a in the Configuration Menu.

2

Type the command letter of the item to be changed in the

System Administration Configuration Menu.

3

Type the information at the prompt.

See Table 3-1 for a description of each parameter.

Note: Each parameter is limited to 64 characters, including spaces.

To cancel a selected option, press ctrl-c at the command prompt.

4

Press Return.

The IntraChassis 9000 system administration information changes take effect.

5

Type q to quit and return to the Configuration menu.

System IP Configuration

This menu displays and allows you to change the information needed to access the IntraChassis 9000 over the network via in-band management.

To access the System IP Configuration Menu, type i in the Configuration

Menu. A screen similar to Figure 3-2 appears.

Page 3-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

Basic Configuration

IntraChassis 9000 System IP Configuration Menu

System MAC Address:

System IP Address:

00:00:92:CC:BB:AA

192.168.54.240 (intrach.asante.com)

System Subnet Mask: 255.255.255.0

System Default Router: 192.168.54.2

<Cmd>

i

m

r

n

q

Command>

<Description>

Set IP Address

Set Subnet Mask

Set Default Router

Set Domain Name Server

Return to Previous Menu

Figure 3-2 System IP Configuration Menu

Important: By default, each address is set to 0.0.0.0.

Current Settings

Table 3-2 describes each setting on the System IP Configuration menu.

Setting

System IP Address

System Subnet Mask

Description

The IP (Internet Protocol) address of the IntraChassis 9000.

The filter which determines how the IntraChassis 9000 IP address is split into network and host portions.

The IP address of the default router for the IntraChassis 9000.

System Default Router

Table 3-2 System IP settings

Changing System IP Information

To change the IP address, subnet mask, or default router of the IntraChassis

9000, use the following procedure.

1

Open the System IP Configuration Menu by typing i in the

Configuration Menu.

2

Type the command letter of the option you want to change.

Page 3-4

GLXY9.book Page 5 Thursday, February 17, 2000 3:04 PM

Bootstrap Configuration

3

Type the new address at the prompt.

See Table 3-2 for a description of each address.

Important: follow the format: number.number.number.number

To cancel a change, press ctrl-c at the command prompt.

4

Press Return.

The IP setting change for the IntraChassis 9000 takes effect.

5

Type q to quit and return to the Configuration Menu.

Bootstrap Configuration

This menu displays (and allows you to change) the bootstrap parameters used for loading the software for the IntraChassis 9000 at startup, and for downloading a new version of software when one is issued.To access the

Bootstrap Configuration Menu, type b in the Configuration Menu. If the

Load Mode is set to LOCAL, a screen similar to Figure 3-3 appears.

IntraChassis 9000 Bootstrap Configuration Menu

Bank 1 Image Version/Date:

Bank 2 Image Version/Date:

Load Mode: Local

Boot Bank: 2

1.00B/May 3 1999 10:00:07 (Running)

1.00G/May 5 1999 17:32:18

<Cmd>

r

a

q

Command>

<Description>

Set Load Mode to REMOTE

Toggle Boot Bank

Return to previous menu

Figure 3-3 Local Bootstrap Configuration Menu

When the IntraChassis 9000 is powered on, it loads its software via one of two methods: locally (via its internal flash memory which is the default setting) or remotely over the network.

Important: The default Load Mode setting for the IntraChassis 9000 is Local.

Page 3-5

GLXY9.book Page 6 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Image Banks

The IntraChassis 9000 has two banks to store its runtime software. The banks are referred to as bank 1 and bank 2.

Either of these banks may be the Boot Bank, which is the bank from which the runtime code will be loaded the next time the IntraChassis 9000 is booted.

When downloading new runtime image codes, you may specify either of the two banks as the Destination Bank in which the new code will be loaded.

Page 3-6

GLXY9.book Page 7 Thursday, February 17, 2000 3:04 PM

Bootstrap Configuration

Loading Software Locally

The IntraChassis 9000 will always boot locally unless you set it to boot load remotely. It would then download the new image code and reset to load locally.

1

Open the Bootstrap Configuration Menu by typing b in the

Configuration Menu.

2

Type a in the Bootstrap Configuration Menu if you need to toggle the Boot Bank setting for the next boot. Typically, you will want to set the boot bank to be the one on which the latest version of the Image resides.

The IntraChassis 9000 is set to load software locally from its flash memory. This occurs whenever the unit is powered on or reset.

Loading Software Remotely

To set the IntraChassis 9000 to download its software over the network from a remote server, use the following procedure.

1

Open the Local Bootstrap Configuration Menu by typing b in Configuration Menu.

2

Open the Remote Bootstrap Configuration Menu by typing

r in the Local Bootstrap Configuration Menu. The menu

appears, as shown in Figure 3-4.

Page 3-7

GLXY9.book Page 8 Thursday, February 17, 2000 3:04 PM

Basic Configuration

IntraChassis 9000 Bootstrap Configuration Menu

Bank 1 Image Version/Date: 1.10J/Dec 7 1999 12:14:38 (Running)

Bank 2 Image Version/Date: 1.00G/May 5 1999 17:32:18

Load Mode: Remote

Boot Mode: TFTP only

Boot Server IP: 192.168.54.150

Boot File Name: c:\base\newcrc.ima

Retry Count: 5

Boot Bank: 1

<Cmd>

b

t

l

s

f

c

a

q

Command>

<Description>

Set Boot Mode to BOOTP-TFTP

Set Boot Mode to TFTP only

Set Load Mode to LOCAL

Set Boot Server IP Address

Set Boot File Name

Set Remote Boot Retry Count

Toggle Boot Bank

Return to Previous Menu

Figure 3-4 Remote Bootstrap Configuration Menu

Page 3-8

GLXY9.book Page 9 Thursday, February 17, 2000 3:04 PM

Bootstrap Configuration

Current Settings

Table 3-3 explains each setting on the Remote Bootstrap Configuration Menu.

Setting

Running Image Version/

Date

Load Mode

Boot Mode

Boot Server IP

Boot File Name

Retry Count

Boot Bank

Description

The version and compilation date of runtime code that is currently running on the IntraChassis 9000.

The current method for loading software for the IntraChassis

9000.

Remote — Loads the image file from a server on the network.

Local — Executes the software image file from the IntraChassis

9000’s internal flash memory (default setting; the IntraChassis

9000 automatically reverts to this setting after downloading a new software file).

The method for requesting the image file from the network. This option is available only if you have selected Remote Load Mode.

BootP-TFTP — Sets the IntraChassis 9000 to request an IP address from a BootP server AND to download the software’s image file through TFTP (Trivial File Transfer Protocol).

Important: To use this option, the IntraChassis 9000 IP address must be set to 0.0.0.0.

TFTP ONLY — Sets the IntraChassis 9000 to only download the software image file through TFTP.

Important: To use this option, the switch must already have an assigned IP address and the Load

Mode must be set to Remote.

The Internet Protocol (IP) address of the TFTP server providing the TFTP capabilities on your network. Not Available if Boot

Mode is BootP-TFTP.

The name of the file you are going to request for download. Not available if boot mode is BootP/TFTP.

Number of attempts the IntraChassis 9000 makes to download the image file if errors occur. The default is 5.

Number of the destination bank for the image file you are downloading (1 or 2).

Table 3-3 Bootstrap Settings

Page 3-9

GLXY9.book Page 10 Thursday, February 17, 2000 3:04 PM

Basic Configuration

3

Type b to set the Boot Mode to BootP-TFTP, or type t to set Boot Mode to TFTP only. If you choose BootP-TFTP mode, the options for setting the IP Address of the TFTP server and the Boot File Name become unavailable; in this case, skip Steps 4-7 and go on to Step 8.

4

Type s in the Bootstrap Configuration Menu, to select the option Set Boot Server IP Address.

5

At the prompt, type the IP address of the remote boot server which contains the switch’s software image file. Then press

Return. The Bootstrap Configuration Menu appears.

6

Type f to select the option Set Boot File Name.

7

Type the software’s file name/network path at the prompt.

8

Press Return.

Note: If you decide to use Local Load Mode rather than Remote, type l. The Local Bootstrap Configura-

tion Menu appears, as shown in Figure 3-3.

The IntraChassis 9000 is now set to download its software remotely from the network. This will occur the next time the unit is powered on or reset.

Page 3-10

GLXY9.book Page 11 Thursday, February 17, 2000 3:04 PM

SNMP Configuration

SNMP Configuration

The s option in the Configuration menu displays the SNMP (Simple Network

Management Protocol) Configuration Menu of the IntraChassis 9000, as

shown in Figure 3-5. For further details on using SNMP and RMON for

remote management of your network, see Chapter 5, "Advanced

Management".

This menu allows you to configure the unit’s read and write community strings, and enable or disable authentication traps. It also allows you to specify which of your network management stations will receive traps from the IntraChassis

9000.

IntraChassis 9000 SNMP Configuration Menu

SNMP Read Community: public

SNMP Write Community: private

Authentication Trap: Enabled

SNMP Trap Receivers:

IP Address

1. 192.168.54.150

2. 192.168.54.110

3. <EMPTY>

4. <EMPTY>

Community private

Sarah

<EMPTY>

<EMPTY>

<Cmd>

r

w

t

a

d

q

Command>

<Description>

Set SNMP Read Community

Set SNMP Write Communtiy

Toggle Trap Authentication Enable/Disable

Add/Update SNMP Trap Receiver

Delete SNMP Trap Receiver

Return to Previous Menu

Figure 3-5 SNMP Configuration menu

Page 3-11

GLXY9.book Page 12 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Current Settings

Table 3-4 describes each setting on the SNMP Configuration Menu.

Setting

SNMP Read Community

SNMP Write Community

Trap Authentication

SNMP Trap Receivers

Description

The string that defines access rights for reading SNMP data objects. The default is public.

The string that defines access rights for writing SNMP data objects. The default is private.

The status of the SNMP agent for authentication trap generation.

The default is disabled.

The IP addresses of the network management stations that can receive traps from the IntraChassis 9000.

Normally, these addresses are the same as your network management software systems’ IP addresses.

Important: A maximum of four trap receivers is allowed.

Table 3-4 SNMP Settings

Changing Community Strings

To change the IntraChassis 9000 community strings, use the following procedure.

1

Open the SNMP Configuration Menu by typing n in the

Configuration Menu.

2

Type r to change the read community string or w to change the write community string.

3

Type a new community string at the prompt.

See Table 3-4 for a description of read and write commu-

nity strings.

To cancel a selected option, press ctrl-c at the command prompt.

4

Press Return. The new string takes effect.

5

Type q to quit and return to the Configuration Menu.

Page 3-12

GLXY9.book Page 13 Thursday, February 17, 2000 3:04 PM

SNMP Configuration

Enabling Authentication Traps

The IntraChassis 9000 can be set to generate authentication traps.

Authentication traps are messages sent across the network to an SNMP network management station. They alert you when someone attempts to read or change data without the proper community string.

To set the IntraChassis 9000 to generate traps, use the following procedure.

1

Open the SNMP Configuration Menu by typing n in the

Configuration Menu.

2

Type a to toggle trap authentication to enabled.

To cancel the change, press ctrl-c at the command prompt.

3

Press Return. The new setting takes effect.

4

Type q to quit and return to the Configuration Menu.

Adding or Updating a Trap Receiver

Trap receivers are network management stations designated to receive traps from the IntraChassis 9000.

Important: The maximum number of trap receivers that can be set is four.

To add or update a trap receiver entry, use the following procedure.

1

Open the SNMP Configuration Menu by typing n in the

Configuration Menu.

2

Type a to Add a Trap Receiver. An IP prompt appears.

3

Type the new or updated IP address of the network management station you want to receive traps, then press Return.

To cancel an entry, press ctrl-c at the command prompt.

4

Type the trap receiver’s community string at the prompt for it, then press Return again.

The trap receiver entry is added or updated. Type q to return to the Configuration Menu.

Deleting a Trap Receiver

Use the following procedure to delete a trap receiver you have previously designated.

Page 3-13

GLXY9.book Page 14 Thursday, February 17, 2000 3:04 PM

Basic Configuration

1

Open the SNMP Configuration Menu by typing n in the

Configuration Menu.

2

Type d to Delete a Trap Receiver. A prompt for the entry of the trap receiver appears.

3

Enter the number of the entry you want to delete (1,2,3, or

4) and press Return.

The trap receiver is deleted from the SNMP Trap Receivers list.

Port Configuration

This menu allows you to configure manually each of the IntraChassis 9000’s ports for port speed, duplex, and auto-negotiation.

It also provides an overview of the entire IntraChassis 9000 system’s port operating status.

To access the Port Configuration Menu, type p in the Configuration Menu. A

screen similar to Figure 3-6 appears.

System Module Map

=================

Please select one of the following slots

Slot

----

1

2

3

4

5

6

7

8

9

Description (Module Type)

--------------------------------------

24 10/100BaseTX ports Module (24-100TX)

2 1000BaseX ports Module (2-GBIC)

24 10/100BaseTX ports Module (24-100TX)

2 1000BaseX ports Module (2-GBIC)

<none>

<none>

<none>

<none>

<none>

Enter Module Number (1-8)>

Figure 3-6 System module map screen

Choose the module for which you want see a port configuration menu. If, for

example, you chose slot 1, you would see a screen similar to Figure 3-7.

Page 3-14

GLXY9.book Page 15 Thursday, February 17, 2000 3:04 PM

Port Configuration

IntraChassis 9000 Basic Port Configuration MenuModule Type: (24-100TX)

Module: [1] Port: [1]

1 8 9 16 17 24

======== ======== ========

Operating Status: +------- -------- --------

Auto Negotiation: ******** ******** ********

Link Speed/Duplex: Fhhhhhhh hhhhhhhh hhhhhhhh

Port Status: Enabled

Auto-Neg: Enabled [ABCD]

Link Status: Up (24-100TX)

Link Speed: 10Mbps (Half Duplex)

<Cmd>

h

t

u

l

d

o

r

a

g

q

<Description>

Help for legends

Toggle Port Status Enable/Disable

Toggle Auto-Negotiation/Manual

Toggle 10M/100M bps Link Speed

Toggle Half/Full Duplex

Modify Auto-Negotiation Advertisement

Restart Auto-Negotiation

Advanced Port Configuration

Global Port Configuration

Return to Previous Menu

Command>

Select module Next module Prev module Select port Next port Prev port

Figure 3-7 Port Configuration Menu for 10/100BaseTX modules

Page 3-15

GLXY9.book Page 16 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Viewing Legends for Configuration Settings

To see legends explaining the symbols used for both the basic and global port

configuration menu settings, type h. A screen similar to Figure 3-8 appears.

Legends for port status: Legends for port speed & duplex:

X - Absent

- - Link down

D - Disabled by Mgmt Action d - Disabled by Security Violation

B - Blocking

S - Listening

R - Learning

+ - Forwarding

Legends for Enable/Disable State:

- - Disabled

* - Enabled f - 10 Mbps & full duplex

F - 100 Mbps & full duplex h - 10 Mbps & half duplex

H - 100 Mbps & half duplex

Legends for port priority:

(The range is from 0 to 3)

0 - priority 0 (lowest)

1 - priority 1 (lower)

2 - priority 2 (higher)

3 - priority 3 (highest)

Legends for Auto-Negotiation Advertisement:

A - 100Base-TX full duplex mode

B - 100Base-TX half duplex mode

C - 10Base-T full duplex mode

D - 10Base-T half duplex mode

Press any key to continue...

Figure 3-8 Legends for all Port Configuration menus

Page 3-16

GLXY9.book Page 17 Thursday, February 17, 2000 3:04 PM

Port Configuration

Current Port Settings

The current module and port for which statistics are displayed is shown in the

top right corner of the Port Configuration menu. Table 3-5 describes each

setting on the Port Configuration menu.

Setting

Module Number

Module Type

Port Number

Operating Status

Auto Negotiation

Link Speed/Duplex

Port Status

Link Status

Auto-Neg

Description

The number of the module of which the selected port is a member.

Code for the type of module: 24-100TX, or 2-GBIC: See

Figure 3-6 for the full names of each module type.

The number of the port for which parameters are shown.

This field displays status symbols for each of the current module’s

ports. See the legend in Figure 3-8 for details.

This field displays disabled/enabled symbols for each of the cur-

rent ports. See the legend in Figure 3-8 for details.

This field displays speed/duplex setting symbols for each of the

current ports. See the legend in Figure 3-8 for details.

Tells whether the selected port is enabled or disabled.

Tells whether the selected port’s link is up or down. ‘Up’ indicates a network device is connected to the port. ‘Down’ indicates that either a device isn’t connected or that the device is powered down.

The port’s link speed and duplex mode are in parentheses.

Tells whether auto-negotiation is enabled or disabled for the selected port, and for which modes, A, B, C, or D. See the legend

in Figure 3-8 for details.

Tells the speed and duplex mode of the port’s current link.

Link Speed

Table 3-5 Port Configuration Menu settings

Enabling or Disabling a Port

The enabling or disabling of a port is a manual operation that can be used to isolate network devices possibly causing problems on the network or to prevent unauthorized use of a port or station.

To enable or disable a port, use the following procedure.

Page 3-17

GLXY9.book Page 18 Thursday, February 17, 2000 3:04 PM

Basic Configuration

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

3

In the Basic Port Configuration Menu, use s, n, or p to select the port you want to enable or disable.

4

Type t to toggle the port’s connection to either enabled or

disabled status, as desired.

The port’s status is changed immediately, and it is reflected in the Port Status displayed near the top of the Port Configuration menu, and the Operating

Status symbol shown for the port.

Configuring Auto-negotiation

Auto-negotiation is a feature of the Fast Ethernet standard that enables two devices on a common segment to communicate their transmission speed capabilities. This feature allows the devices to determine and use their highest common speed and best communication parameters.

Important: By default, all of the ports are set to Auto-nego-

tiation, as shown in Figure 3-7.

To enable Auto-negotiation, or return to manual-setting mode, use the following procedure.

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

3

In the Basic Port Configuration Menu, use s, n, or p to select the port for which you want to set the auto-negotiation mode.

4

Type u to toggle the port’s auto-negotiation mode to

enabled or to return it to manual.

The auto-negotiation status changes immediately, and is displayed on the Auto

Negotiation line near the top of the Port Configuration menu.

Important: If you change the status of the port from Man-

ual to Enabled you must type r to restart Auto-negotiation.

Page 3-18

GLXY9.book Page 19 Thursday, February 17, 2000 3:04 PM

Port Configuration

Configuring a Port Manually

If you have changed the Auto-negotiation status of a port to Manual, as described in the previous section, you can toggle the link speed from 10Mbps to

100Mbps and back, and toggle the port from half to full duplex and back.

Toggling Port Link Speed

Use the following procedure to toggle the port’s link speed.

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

3

In the Basic Port Configuration Menu, use s, n, or p to select the port for which you want to set the link speed.

4

Type l to toggle the port’s link speed.

The link speed is changed immediately, and the change is reflected on the Link

Speed line near the top of the Port Configuration menu.

Toggling Half to Full Duplex

Half duplex mode allows transmission in two directions on the same channel, but only in one direction at a time. Full duplex mode allows transmission in two directions on the same channel at the same time.

Important: To use full duplex mode, the device to which the port is connected must support and be configured for duplex mode.

Use the following procedure to change the duplex mode setting for a port that is in Manual status.

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

3

In the Basic Port Configuration Menu, use s, n, or p to select the port for which you want to set the duplex mode.

4

Type d to toggle the port’s duplex mode.

The change in mode is reflected immediately in the Link Speed/Duplex line near the top of the Port Configuration menu.

Page 3-19

GLXY9.book Page 20 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Configuration of 1000BaseX ports

The following sections describe the configuration options in the Port

Configuration Menu for a 1000BaseX port. Since the 1000BaseX ports are always in full duplex mode, the only configuration possible is enabling and disabling the port.

To access the 1000BaseX port menu, type p in the Configuration menu, and

when you see the System Module Map, as shown in Figure 3-6, enter the

number of a module with 1000BaseX ports (such as module 2 in the map

shown in Figure 3-6). The Configuration menu for 1000BaseX ports appears,

as shown in Figure 3-9.

IntraChassis 9000 Basic Port Configuration Menu Module Type: (2-GBIC)

Module: [1]

Port

Port: [1]

1 Port 2

=========== ===========

Operating Status: SX-LinkUp (Forwarding) SX-LinkDown

Port Status: Enabled Link Status: Up [1000Mbps-Full]

<Cmd>

h

t

a

g

q

<Description>

Help for legends

Toggle Port Status Enable/Disable

Advanced Port Configuration

Global Port Configuration

Return to Previous Menu

Command>

Select module Next module Prev module Select port Next port Prev port

Figure 3-9 Port Configuration menu for 1000BaseX ports

For a description of the current settings shown in the top portion of the screen,

see “Current Port Settings” on page 3-17.

Enabling or Disabling a Port

The enabling or disabling of a port is a manual operation that can be used to isolate network devices possibly causing problems on the network.

To enable or disable a port, use the following procedure.

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

3

In the Basic Port Configuration Menu, use s, n, or p to

Page 3-20

GLXY9.book Page 21 Thursday, February 17, 2000 3:04 PM

Port Configuration select the port you want to enable or disable.

4

Type t to toggle the port’s connection to either enabled or

disabled status, as desired.

The port’s status is changed immediately, and it is reflected in the Port Status displayed near the top of the Port Configuration menu.

Page 3-21

GLXY9.book Page 22 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Advanced Port Configuration

The Advanced Port Configuration menu allows you to control the port broadcast and multicast rate, to enable or disable 802.3x flow control, and to set the default priority of the port. To access the Advanced Port Configuration menu, first access either the 10/100BaseTX or the 1000BaseX Port

Configuration menu, as described earlier in this chapter, then type a to see the

Advanced Port Configuration menu, as shown in Figure 3-10 and Figure 3-11.

Advanced 10/100BaseTX Port Configuration

The following sections explain the configuration options in the Advanced Port

Configuration menu for 10/100BaseTX ports.

IntraChassis 9000 Advanced Port Configuration Menu Module Type: (24-100TX)

Module: [1] Port: [1]

1 8 9 16 17 24

======== ======== ========

Operating Status: +------- -------- --------

Flow Ctrl: *------- -------- --------

Priority: 10001111 11111122 23333333

Max. Broadcast Rate:

Max. Multicast Rate:

802.3x Flow Control:

Port Default Priority:

N/A

N/A

Enabled

1

<Cmd>

h

r

f

i

q

<Description>

Help for legends

Set Max. Broadcast/Multicast Rate

Toggle 802.3x Flow Control Enable/Disable

Set Port Default Priority

Return to Previous Menu

Command>

Select module Next module Prev module Select port Next port Prev port

Figure 3-10 Advanced Port Configuration menu - 10/100BaseTX port

For a legend of the symbols used for the flow control and port priority table,

type h and you will see the screen displayed in Figure 3-8.

Current Settings

The settings shown in the top portion of the Advanced Port Configuration

menu are described in Table 3-6.

Page 3-22

GLXY9.book Page 23 Thursday, February 17, 2000 3:04 PM

Advanced Port Configuration

Setting

Module Number

Module Type

Operating Status

Flow Control

Priority

Max. Broadcast Rate

Max. Multicast Rate

Description

The number of the module of which the selected port is a member.

Code for the type of module: 24-100TX, 2-GBIC, or 8-100FX:

See Figure 3-6 for the full names of each module type.

This field displays status symbols for each of the current module’s

ports. See the legend in Figure 3-8 for details.

The status of flow control for the current port.When enabled, it allows you to control traffic and avoid congestion, such as when the port is receiving too much traffic for the available buffer resources.

The priority ranking for the port in regards to data transmission during periods of peak or heavy on the network. Ports with higher priority take precedence when there is traffic congestion.

The maximum number of packets per second that can be broadcast by the current port to the network

The maximum number of packets that can be multicast to all or selected ports on the network by the current port.

Table 3-6 Advanced Port Configuration menu settings

Setting the Maximum Broadcast or Multicast Rate

Use the following procedure to set a limit on how many packets may be either broadcast or multicast from the current port.

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

3

In the Basic Port Configuration Menu, type a to open the

Advanced Port Configuration menu.

4

Use s, n, or p to select the port for which you want to set the broadcast or multicast rate.

5

Type r to set the maximum broadcast or multicast rate for the selected port.

Page 3-23

GLXY9.book Page 24 Thursday, February 17, 2000 3:04 PM

Basic Configuration

6

Enter the rate for broadcast or multicast and press Return.

The new maximum rate is displayed on the Advanced Port Configuration menu.

Enabling or Disabling 802.3x Flow Control

Use the following procedure to control traffic and avoid congestion, such as when there is a shortage of buffer resources for the port. Flow control is accomplished by means of standard PAUSE control frames for each port, independent of all others. The port must be configured to operate in Full

Duplex mode. If you enable flow control on a port which is overwhelmed (runlow in the buffer resources), that port will transmit PAUSE frames; the link partner will obey the PAUSE frame. When the low-resource situation is relieved, the port sends out PAUSE frames with zero time value to un-pause the end-station. To enable flow control, first access the Port Configuration menu by typing p in the Configuration menu, then take the following steps.

1

Choose a module in the System Module Map.

2

In the Basic Port Configuration Menu, type a to open the

Advanced Port Configuration menu.

3

Use s, n, or p to select the port for which you want to enable or disable flow control.

4

Type f to toggle flow control for the selected port.

The flow control symbol for the selected port reflects its change in state, as does the 802.3x Flow Control setting.

Important: The link partner must be configured to recognize PAUSE frames when using this method of flow control.

Setting Port Default Priority

Use the following procedure to set a higher or lower priority for a port. This priority setting determines the order in which the port forwards packets. Each port is associated with a traffic class; 0 (zero) is the lowest, and the default priority level, and 1 is the highest priority level.

1

Access the Port Configuration menu by typing p in the

Configuration menu.

2

Choose a module in the System Module Map.

Page 3-24

GLXY9.book Page 25 Thursday, February 17, 2000 3:04 PM

Advanced Port Configuration

3

In the Basic Port Configuration Menu, type a to open the

Advanced Port Configuration menu.

4

Use s, n, or p to select the port for which you want to set the default priority.

5

Type i to set the priority for the selected port.

6

Enter the priority, from 0 or 1, and press Return.

The new default priority is shown on the Advanced Port Configuration menu.

Page 3-25

GLXY9.book Page 26 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Advanced 1000BaseX Port Configuration

If you are in the Basic Port Configuration menu for a 1000BaseX port and type

a the menu shown in Figure 3-11.

IntraChassis 9000 Basic Port Configuration Menu Module Type: (2-GBIC)

Module: [1]

Port: [1] Port 1 Port 2

Flow Ctrl:

Priority:

=========== ===========

SX-LinkUp (Forwarding) SX-LinkDown

1 1

Max. Broadcast Rate:

Max. Multicast Rate:

802.3x Flow Control:

Port Default Priority:

N/A

N/A

Enabled

1

<Cmd>

h

r

f

i

q

<Description>

Help for legends

Set Max. Broadcast/Multicast Rate

Toggle 802.3x Flow Control Enable/Disable

Set Port Default Priority

Return to Previous Menu

Command>

Select module Next module Prev module Select port Next port Prev port

Figure 3-11 Advanced Port Configuration menu - 1000BaseX port

To change the maximum broadcast or multicast rate, or to enable or disable flow control, or to set the default priority for a 1000BaseX port, use the

procedures in the “Advanced 10/100BaseTX Port Configuration” section.

Global Port Configuration

This menu allows you to change the configuration information for all ports simultaneously. This feature is helpful in cases where you want the same configuration for all ports in a module.

Type g in the Basic Port Configuration menu for either 10/100BaseTX or

1000BaseX ports to display the Global Port Configuration Menu, as shown in

Figure 3-12 and Figure 3-13.

Page 3-26

GLXY9.book Page 27 Thursday, February 17, 2000 3:04 PM

Global Port Configuration

IntraChassis 9000 Global Port Configuration MenuModule Type: (24-100TX)

Module: [1]

1 8 9 16 17 20

======== ======== ========

Operating Status: +------- -------- --------

Auto Negotiation: ******** ******** ********

Link Speed/Duplex: Fhhhhhhh hhhhhhhh hhhhhhhh

Flow Ctrl: *------- -------- --------

Priority: 00001111 11111122 22333333

<Cmd>

h

t

u

l

d

o

r

f

i

q

<Description>

Help for legends

Select Global Ports Status Enable/Disable

Select Global Auto-Negotiation/Manual

Select Global 10M/100M bps Link Speed

Select Global Half/Full Duplex

Modify Global Auto-Negotiation Advertisement

Set Global Max. Broadcast/Multicast Rate

Toggle Global 802.3x Flow Control Enable/Disable

Set Global Port Devault Priority

Return to Previous Menu

Command>

Select module Next module Prev module

Figure 3-12 Global Port Configuration menu - 10/100BaseTX ports

IntraChassis 9000 Global Port Configuration MenuModule Type: (2-GBIC)

Module: [1]

Port 1 Port 2

=========== ===========

Operating Status: SX-Enabled SX-Enabled

Flow Ctrl: Disabled Disabled

Priority: 1 0

<Cmd>

h

t

r

f

i

q

<Description>

Help for legends

Select Global Port Status Enable/Disable

Set Global Max. Broadcast/Multicast Rate

Toggle Global 802.3x Flow Control Enable/Disable

Set Global Port Default Priority

Return to Previous Menu

Command>

Select module Next module Prev module

Figure 3-13 Global Port Configuration menu - 1000BaseX ports

Page 3-27

GLXY9.book Page 28 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Use the procedures in the “Port Configuration” and “Advanced Port

Configuration” sections of this chapter. The same procedures are used for global

configuration, except that you do not need to choose a module and port to configure. Notice that the advanced configuration options, such as enabling or disabling flow control, are also included in the menu.

Unicast Forwarding Database Configuration

This menu allows the user to view and search for addresses in the IntraChassis

9000’s MAC Forwarding Table. It also provides options for displaying MAC addresses and IP/MAC binding by individual port or by VLAN.

The MAC Forwarding Table is a table of node addresses that the IntraChassis

9000 automatically builds by “learning,” It performs this task by monitoring the packets that pass through the IntraChassis 9000, checking the source and destination addresses, and then recording the source address information in the table.

The IntraChassis 9000 uses the information in this table to decide whether a frame should be forwarded to a particular destination port or “flooded” to all the ports other than the received port. Each entry consists of the MAC address of the device and an identifier for the port on which it was received.

Note: The MAC address table can hold a maximum of

8,192 entries.

When you type d in the Configuration menu, the Unicast Forwarding Database

Configuration menu appears, as shown in Figure 3-14.

Page 3-28

GLXY9.book Page 29 Thursday, February 17, 2000 3:04 PM

Unicast Forwarding Database Configuration

IntraChassis 9000 Unicast Forwarding Database Configuration Menu

Age-out Time: 300 sec.

MAC Address Count: 33

IP Address Count: 21

<Cmd>

a

p

v

m

i

t

q

<Description>

Display All Forwarding Database With/Without IP

Display Forwarding Database By Port With/Without IP

Display Forwarding Database by VLAN With/Without IP

Search for MAC Address

Search for IP Address

Set Age-Out Time

Return to Previous Menu

Command>

Figure 3-14 Unicast Forwarding Configuration menu

Page 3-29

GLXY9.book Page 30 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Current Settings

Table 3-7 explains each setting on the Forwarding Database Configuration

Menu.

Setting

Age-out Time

MAC Address Count

IP Address Count

Description

The number of seconds that addresses are retained in the table.

The default is 300 seconds. The range is from 10 to 1,000,000.

The number of entries currently in the MAC Address Table.

The number of entries in the MAC Address Table that contain a corresponding IP address.

Table 3-7 Forwarding Database Configuration menu settings

Displaying the Forwarding Database

You can display the Forwarding Database MAC address table with or without

IP addresses. Use the following procedure to view the table.

1

Open the Unicast Forwarding Database Configuration

Menu by typing d in the Configuration Menu.

2

Type either a, p, or v , depending on the range of MAC addresses you want to view.

Type a to display the MAC address table with the MAC addresses of all ports on the IntraChassis 9000.

Type p to specify a port, then see the MAC addresses for that port only.

Type v to specify a VLAN, then see the MAC addresses for the member ports of that VLAN only.

3

At the prompt which appears, type y to see IP addresses in the display or type n to see the display without IP addresses, then press Return. The selected display appears, as shown

in Figure 3-15.

Page 3-30

GLXY9.book Page 31 Thursday, February 17, 2000 3:04 PM

Unicast Forwarding Database Configuration

Notes: The Age field in the MAC address tables indicates the amount of time remaining before an entry ages out.

The Type field refers to the type of entry for the MAC address of a device; the setting may be static, S (set by management, and will not age out), or dynamic, D (learned by the switch, and will be aged out) or multiple, M (associated with multiple IP addresses, as in the case of a router), or I

(management module’s MAC address).

The Self entry represents the IntraChassis 9000 MAC address and IP address.

The Pri field refers to the priority setting for the port.

Entry Type: (D = Dynamic, S = Static, I = Self)

+------+----+----+-----------------+-----+---+

|Module|Port|Type| MAC Address | Age |Pri|

+------+----+----+-----------------+-----+---+

1

1

1

1

6

6

6

6

D

D

D

D

00:00:94:10:80:1D

00:E0:52:01:44:46

00:00:94:A2:DE:56

00:00:94:7A:CF:48

159

147

300

9

0

0

0

0

1

1

1

1

1

--

1

1

6

--

6

6

6

6

6

6

D

I

D

D

D

D

D

D

00:00:94:92:F1:A8

00:00:94:8E:F2:CC

00:00:94:5D:E0:41

00:00:94:5D:E1:9E

08:00:20:80:5E:9C

00:00:94:5D:E2:15

00:00:94:5D:E2:8D

00:00:94:10:E3:12

300

--

285

234

270

300

276

246

0

0

0

0

0

0

0

0

1

1

1

1

6 D 08:00:20:72:A0:1C 81 0

6 D 00:00:94:7B:02:C0 291 0

6 D 00:00:94:75:34:DE 3 0

6 D 00:00:94:75:31:DB 21 0

1

1

6 D 00:A0:CC:2C:60:CB 144 0

6 D 00:00:94:9A:2F:1C 150 0

1 6 D 00:00:94:75:2F:CF 297 0

Press Next, Previous, or Quit

Figure 3-15 Unicast Forwarding Database, all ports, without IP displayed

The first screen of the MAC address display for all ports shows the entries for devices connected to the ports of the first module; if you scroll through the database, you can see the entries for each port of each module. For example, some MAC addresses for devices connected to port 6 of module 1 are shown in

Figure 3-15.

Page 3-31

GLXY9.book Page 32 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Entry Type [T]: (D = Dynamic, S = Static, M = Multiple, I = Self)

+-+-+-+-----------------+----------------+

|M|P|T| MAC Address | IP |

+-+-+-+-----------------+----------------+

1 6 D 00:00:94:10:80:1D 199.35.192.185

1 6 D 00:E0:52:01:44:46 199.35.192.189

1 6 D 00:00:94:A2:DE:56 199.35.192.181

1 6 D 00:00:94:7A:CF:48 199.35.192.188

1 6 D 00:00:94:92:F1:A8 199.35.192.182

- - I 00:00:94:8E:F2:CC 199.35.192.187

1 6 D 00:00:94:5D:E0:41 199.35.192.183

1 6 D 00:00:94:5D:E1:9E 199.35.192.186

1 6 D 08:00:20:80:5E:9C 199.35.192.184

1 6 D 00:00:94:5D:E2:15 199.35.192.195

1 6 D 00:00:94:5D:E2:8D 199.35.192.199

1 6 D 00:00:94:10:E3:12 199.35.192.191

1 6 D 08:00:20:72:A0:1C 199.35.192.198

1 6 D 00:00:94:7B:02:C0 199.35.192.192

1 6 D 00:00:94:75:34:DE 199.35.192.197

1 6 D 00:00:94:75:31:DB 199.35.192.193

1 6 D 00:A0:CC:2C:60:CB 199.35.192.196

1 6 D 00:00:94:9A:2F:1C 199.35.192.194

1 6 D 00:00:94:75:2F:CF 199.35.192.175

Press Next, Previous, or Quit

Figure 3-16 Unicast Forwarding Database, all ports, with IP displayed

The Unicast Forwarding Database display does not show the age or priority of

the devices, as you can see in Figure 3-16.

Page 3-32

GLXY9.book Page 33 Thursday, February 17, 2000 3:04 PM

Unicast Forwarding Database Configuration

Module: [1] Port: [6]

Entry Type: (D = Dynamic, S = Static,I = Self)

+----+-----------------+-----+---+

|Type| MAC Address | Age |Pri|

+----+-----------------+-----+---+

D 00:00:94:10:80:1D 159 0

D 00:E0:52:01:44:46 147 0

D 00:00:94:A2:DE:56 300 0

D 00:00:94:7A:CF:48 9 0

D 00:00:94:92:F1:A8 300 0

D 00:00:94:8E:F2:CC 0 0

D 00:00:94:5D:E0:41 285 0

D 00:00:94:5D:E1:9E 234 0

D 08:00:20:80:5E:9C 270 0

D 00:00:94:5D:E2:15 300 0

D 00:00:94:5D:E2:8D 276 0

I 00:00:94:10:E3:12 -0

D 08:00:20:72:A0:1C 81 0

D 00:00:94:7B:02:C0 291 0

D 00:00:94:75:34:DE 3 0

D 00:00:94:75:31:DB 21 0

D 00:A0:CC:2C:60:CB 144 0

D 00:00:94:9A:2F:1C 150 0

D 00:00:94:75:2F:CF 297 0

Press Next, Previous, or Quit

Figure 3-17 Unicast Forwarding Database for a port, without IP displayed

The Unicast Forwarding Database display for a single port shows only the

entries for the devices connected to the selected port, as you can see in Figure 3-

17.

Page 3-33

GLXY9.book Page 34 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Module: [1] Port: [6]

Entry Type [T]: (D = Dynamic, S = Static, M = Multiple, I = Self)

+-+-+-+-----------------+----------------+

|M|P|T| MAC Address | IP |

+-+-+-+-----------------+----------------+

1 6 D 00:00:94:10:80:1D 199.35.192.185

1 6 D 00:E0:52:01:44:46 199.35.192.189

1 6 D 00:00:94:A2:DE:56 199.35.192.181

1 6 D 00:00:94:7A:CF:48 199.35.192.188

1 6 D 00:00:94:92:F1:A8 199.35.192.182

- - I 00:00:94:8E:F2:CC 199.35.192.187

1 6 D 00:00:94:5D:E0:41 199.35.192.183

1 6 D 00:00:94:5D:E1:9E 199.35.192.186

1 6 D 08:00:20:80:5E:9C 199.35.192.184

1 6 D 00:00:94:5D:E2:15 199.35.192.195

1 6 D 00:00:94:5D:E2:8D 199.35.192.199

1 6 D 00:00:94:10:E3:12 199.35.192.191

1 6 D 08:00:20:72:A0:1C 199.35.192.198

1 6 D 00:00:94:7B:02:C0 199.35.192.192

1 6 D 00:00:94:75:34:DE 199.35.192.197

1 6 D 00:00:94:75:31:DB 199.35.192.193

1 6 D 00:A0:CC:2C:60:CB 199.35.192.196

1 6 D 00:00:94:9A:2F:1C 199.35.192.194

1 6 D 00:00:94:75:2F:CF 199.35.192.175

Press Next, Previous, or Quit

Figure 3-18 Unicast Forwarding Database for a port, with IP displayed

The Unicast Forwarding Database display does not show the age or priority of

the devices, as you can see in Figure 3-18.

Page 3-34

GLXY9.book Page 35 Thursday, February 17, 2000 3:04 PM

Unicast Forwarding Database Configuration

VLAN ID: [1]

Entry Type: (D = Dynamic, S = Static, I = Self)

+------+----+----+-----------------+-----+---+

|Module|Port|Type| MAC Address | Age |Pri|

+------+----+----+-----------------+-----+---+

1 6 D 00:00:94:10:80:1D 159 0

1

1

6

6

D

D

00:E0:52:01:44:46

00:00:94:A2:DE:56

147

300

0

0

1

1

--

1

1

1

1

6

6

--

6

6

6

6

D

D

I

D

D

D

D

00:00:94:7A:CF:48

00:00:94:92:F1:A8

00:00:94:8E:F2:CC

00:00:94:5D:E0:41

00:00:94:5D:E1:9E

08:00:20:80:5E:9C

00:00:94:5D:E2:15

9

300

--

285

234

270

300

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

6

6

6

6

6

6

6

6

D

D

D

D

D

D

D

D

00:00:94:5D:E2:8D

00:00:94:10:E3:12

08:00:20:72:A0:1C

00:00:94:7B:02:C0

00:00:94:75:34:DE

00:00:94:75:31:DB

00:A0:CC:2C:60:CB

00:00:94:9A:2F:1C

276

246

81

291

3

21

144

150

0

0

0

0

0

0

0

0

1 6 D 00:00:94:75:2F:CF 297 0

Press Next, Previous, or Quit

Figure 3-19 Unicast Forwarding Database for a VLAN, without IP displayed

The display for a single VLAN shows only the entries for devices connected to

the member ports of the selected VLAN, as seen in Figure 3-19.

Page 3-35

GLXY9.book Page 36 Thursday, February 17, 2000 3:04 PM

Basic Configuration

VLAN ID: [1]

Entry Type [T]: (D = Dynamic, S = Static, M = Multiple, I = Self)

+-+-+-+-----------------+----------------+

|M|P|T| MAC Address | IP |

+-+-+-+-----------------+----------------+

1 6 D 00:00:94:10:80:1D 199.35.192.185

1 6 D 00:E0:52:01:44:46 199.35.192.189

1 6 D 00:00:94:A2:DE:56 199.35.192.181

1 6 D 00:00:94:7A:CF:48 199.35.192.188

1 6 D 00:00:94:92:F1:A8 199.35.192.182

- - I 00:00:94:8E:F2:CC 199.35.192.187

1 6 D 00:00:94:5D:E0:41 199.35.192.183

1 6 D 00:00:94:5D:E1:9E 199.35.192.186

1 6 D 08:00:20:80:5E:9C 199.35.192.184

1 6 D 00:00:94:5D:E2:15 199.35.192.195

1 6 D 00:00:94:5D:E2:8D 199.35.192.199

1 6 D 00:00:94:10:E3:12 199.35.192.191

1 6 D 08:00:20:72:A0:1C 199.35.192.198

1 6 D 00:00:94:7B:02:C0 199.35.192.192

1 6 D 00:00:94:75:34:DE 199.35.192.197

1 6 D 00:00:94:75:31:DB 199.35.192.193

1 6 D 00:A0:CC:2C:60:CB 199.35.192.196

1 6 D 00:00:94:9A:2F:1C 199.35.192.194

1 6 D 00:00:94:75:2F:CF 199.35.192.175

Press Next, Previous, or Quit

Figure 3-20 Unicast Forwarding Database for a VLAN, with IP displayed

The VLAN display does not show the age or priority of the devices, as you can

see in Figure 3-20.

Searching for a MAC Address

The MAC address table can be searched by MAC address or by IP address. To search the MAC address table for a specific MAC or IP address, use the following procedure.

1

Access the Unicast Forwarding Database Configuration

Menu by typing d in the Configuration menu.

2

Type m to search for a MAC address.

Type i to search for an IP address.

3

Type the MAC or IP address at the prompt.

4

Press return.

The address, if located is displayed, with its associated information, as shown in

Figure 3-21. If the address is not located, a message appears, stating this.

Page 3-36

GLXY9.book Page 37 Thursday, February 17, 2000 3:04 PM

Image File Downloading Configuration

The MAC Address Search Summary

==============================

Module:

Port:

1

6

Type:

Age:

Dynamic

200

Priority: 0

MAC Address: 00:00:94:11:12:13

IP Address: 192.203.54.111

press any key to continue...

Figure 3-21 MAC Address Search summary

The summary screen tells the location of the MAC or IP address; the module, port, and the Domain Name. Configuration information, such as the priority, type, and age are also displayed.

Setting the MAC Address Age-Out Time

This option sets the Age-Out Time for the MAC Forwarding Table.

The Age-Out Time is the number of seconds that addresses remain in the table after being learned by the IntraChassis 9000. The default is 300 seconds.

Use the following procedure to set the MAC address Age-Out Time.

1

Access the Unicast Forwarding Database Configuration

Menu by typing d in the Configuration menu.

2

Type t to set the MAC Address Age-Out Time.

3

Enter the new Age-Out time (in seconds) at the prompt.

4

Press Return.

The MAC Address Age-Out Time is changed and is displayed at the top of the

Unicast Forwarding Database Configuration menu.

Image File Downloading Configuration

You can upgrade your IntraChassis 9000 system easily, using either TFTP or

X/Y/Z modem protocol and the Image File Downloading option of the

Configuration menu.

Page 3-37

GLXY9.book Page 38 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Type f in the configuration menu to see the Image File Downloading

Configuration menu, as shown in Figure 3-22.

IntraChassis 9000 Image File Downloading Configuration Menu

<Cmd>

t

x

q

Command>

<Description>

TFTP Image File Downloading Configuration

X/Y/ZMODEM Image File Downloading Configuration

Return to Previous Menu

Figure 3-22 Image File Downloading Configuration menu

This menu lets you select the downloading protocol. Type t to download the image file via TFTP, and type x to download using the X/Y/Z modem protocol.

The two subsections that follow describe downloading by each of the two protocols.

When Asanté issues a new version of software for the IntraChassis 9000, you can obtain it from the Asanté World Wide Web site or by contacting Asanté

Technical Support (see Appendix A, "Technical Support" for details).

Image Downloading Through TFTP

To download a new image file in-band through TFTP, type t in the Image

Download Configuration Menu (option g in Configuration Menu). A screen

similar to Figure 3-23 appears.

Page 3-38

GLXY9.book Page 39 Thursday, February 17, 2000 3:04 PM

Image File Downloading Configuration

IntraChassis 9000 TFTP File Downloading Menu

Bank 1 Image Version/Date

Bank 2 Image Version/Date

1.00T/May 07 1999 11:34:46

1.00U/Jul 29 1999 15:55:34 (Running)

File Type:

Server IP:

File Name:

Retry Count: 5

Destination Bank: 1

Image

192.203.52.211

c:\base\main\gxrt.ima

<Cmd>

s

f

d

b

r

a

q

Command>

<Description>

Set Server IP Address

Set File Name

Download Image File to Destination Bank

Download and Reboot from the Image File

Set Retry count

Toggle Destination Bank

Return to Previous Menu

Figure 3-23 TFTP Image Downloading menu

Current Settings

Table 3-8 describes each setting on the TFTP Image Downloading menu.

Setting

Bank 1 Image Version/

Date

Bank 2 Image Version/

Date

Server IP

File Name

Retry Count

Destination Bank

Description

The version number and compilation date of runtime code that is stored in memory Bank 1 on the IntraChassis 9000.

The version number and compilation date of runtime code that is stored in memory Bank 2 on the IntraChassis 9000. The (Running) designation indicates that the runtime code is currently running on this Bank. The same as the image file in the boot bank.

IP address of network server containing software image file.

The software image file’s name and network path.

Number of attempts the switch will make to download image file.

Number of the memory bank where the image file will download.

Table 3-8 TFTP Image Download menu settings

Page 3-39

GLXY9.book Page 40 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Performing a Software Upgrade at Runtime

The software image file must be downloaded from a server on your network that is running a TFTP server application.

Important: Make sure the IntraChassis 9000 is configured

with an IP address (see “Changing System IP Information”

earlier in this chapter for details).

Use the following procedure to upgrade the IntraChassis 9000 software via

TFTP.

1

Access the TFTP Image File Downloading Configuration menu by typing t in the Image File Downloading Configuration menu.

2

Type s to set the image server IP address.

3

At the prompt, enter the IP address of the server containing the image file, then press Return.

4

Type f to set the image file name.

5

At the prompt, enter the image file’s name and path, then press Return.

6

Type r to set the retry count.

7

At the prompt, enter the number of attempts the IntraChassis 9000 will make to download the image file, then press

Return.

8

Select the Destination Image Bank by using the a option. In a typical situation, you will want to select the Bank on which the software is not currently running, as shown in

Figure 3-23.

9

Type d to download the image file to the destination bank

(this option allows you to change the boot bank at a later time and use the Reset menu to schedule a reset, at which time the new software will be run).

OR

Type b to download the image file and reset the switch (this option immediately boots the IntraChassis 9000 with the new version of software).

Page 3-40

GLXY9.book Page 41 Thursday, February 17, 2000 3:04 PM

Image File Downloading Configuration

10

Type q to return to the Image File Downloading menu.

Serial Downloading Configuration

The X/Y/Z Modem Image file Downloading Configuration option lets you download a new software image file for the IntraChassis 9000 without interrupting the current operation.

To download a new image through the IntraChassis 9000 management module’s serial (console) port, type x in the Image File Download

Configuration Menu. The X/Y/Z Modem Image File Downloading menu

appears, as shown in Figure 3-24.

IntraChassis 9000 X/Y/ZMODEM Image File Downloading Menu

Bank 1 Image Version/Date

Bank 2 Image Version/Date

1.00T/May 07 1999 11:34:46

1.00U/Jul 29 1999 15:55:34 (Running)

Download Protocol: ZMODEM

Current Baud Rate: 9600 bps

Destination Bank: 1

<Cmd>

x

y

z

c

d

b

a

q

Command>

<Description>

Set download protocol to XMODEM

Set download protocol to YMODEM

Set download protocol to ZMODEM

Change Baud Rate Setting

Download Image File

Download and Boot Image File

Toggle Destination Bank

Return to Previous Menu

Figure 3-24 X/Y/Z Modem Image File Downloading menu

Current Settings

Table 3-9 describes the settings shown in the X/Y/Z Modem Image File

Downloading menu.

Page 3-41

GLXY9.book Page 42 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Setting

Bank 1 Image Version/

Date

Bank 2 Image Version/

Date

Download Protocol

Current Baud Rate

Destination Bank

Description

The version number and compilation date of runtime code that is stored in memory Bank 1 on the IntraChassis 9000.

The version number and compilation date of runtime code that is stored in memory Bank 2 on the IntraChassis 9000.The (Running) designation indicates that the runtime code is currently running on this Bank. The same as the image file in the boot bank.

Current setting of the IntraChassis 9000’s serial download protocol.

Transmission rate for the IntraChassis 9000’s serial port.

Number of the memory bank where the image file will download.

Table 3-9 X/Y/Z Modem Image File Downloading settings

Performing a Software Upgrade

Use the following procedure to upgrade the IntraChassis 9000 software through its serial (console) port.

1

In the Image File Download Configuration menu, type x to open the X/Y/Z Modem Image File Downloading menu.

2

Type x, y, or z to select the corresponding modem protocol.

Note: For information about these protocols, see the manual for your communications software.

3

Type c to select the console baud rate. The Baud Rate Set-

ting menu appears, as shown in Figure 3-25. The maximum

baud rate currently supported is 57,600 bps.

Page 3-42

GLXY9.book Page 43 Thursday, February 17, 2000 3:04 PM

Image File Downloading Configuration

Current Baud Rate: 9600 bps

Please select one from the following baud rate settings, or press any other key to quit:

WARNING: The user must use the same baud rate setting of the terminal after he/she confirms to change the baud rate setting of the console in order to work correctly.

<Cmd>

a

b

c

d

e

f

g

Choice>

<Description>

Set Baud Rate to 1200 bps

Set Baud Rate to 2400 bps

Set Baud Rate to 4800 bps

Set Baud Rate to 9600 bps

Set Baud Rate to 19200 bps

Set Baud Rate to 38400 bps

Set Baud Rate to 57600 bps

Figure 3-25 Baud Rate menu

4

Select one of the options in the above screen to select the required baud rate and confirm it by typing y.

5

Type a to select the Destination Bank.

6

Use any serial communications software like Procomm Plus,

HyperTerminal, ZTerm, etc., to download the image file.

Follow the instruction manual of the serial communications software for file transfer instructions.

Note: The terminal on which serial communications software is running must have the same baud rate as the

IntraChassis 9000 management module console. The connection from the terminal to the switch Console port must be an RS232C straight-through cable.

7

Type d to download to the selected destination bank or b to download and reset.

8

Type q to return to the previous menu after performing a successful download.

Note: The baud rate default for Console management is

9600 bps. If you select a baud rate for the console port other than 9600 bps, the screen will display garbage data until the connected terminal is set to the same baud rate as the console.

Page 3-43

GLXY9.book Page 44 Thursday, February 17, 2000 3:04 PM

Basic Configuration

System Reset Configuration

The System Reset Configuration Menu allows you to reset the IntraChassis

9000 by performing a “warm” reboot. It also allows you to schedule a reset up to 24 hours in advance.

To reset the IntraChassis 9000, type r in the Configuration Menu. A screen

similar to Figure 3-26 appears.

IntraChassis 9000 System Reset Configuration Menu

Reset Status:

Reset Type:

Reset Countdown:

Stop

Normal

1 sec.

<Cmd>

s

c

r

d

i

q

Command>

<Description>

Schedule Reset Time

Cancel Reset

Reset System

Reset Switch to Factory Default

Reset Switch to Factory Default except IP and Bootstrap

Return to Previous Menu

Figure 3-26 System Reset Configuration menu

Current Options

Table 3-10 describes the settings shown in the Reset Configuration menu.

Option

Schedule Reset Time

Cancel Reset

Reset Switch

Reset Switch to Factory

Default

Reset Switch to Factory

Default except IP &

Bootstrap

Description

Number of seconds until the scheduled reset.

Stops the scheduled reset.

Resets the IntraChassis 9000 immediately.

Resets the IntraChassis 9000 to the original factory settings.

Resets the IntraChassis 9000 to the original factory settings without modifying the IP and Bootstrap configuration.

Table 3-10 Reset Configuration options

Page 3-44

GLXY9.book Page 45 Thursday, February 17, 2000 3:04 PM

System Reset Configuration

Resetting the IntraChassis 9000

To reset the IntraChassis 9000, use the following procedure.

1

Open the Reset Menu by typing r in the Configuration

Menu.

2

Type r to reset the IntraChassis 9000.

Note: Typing d will reset the IntraChassis 9000 to the factory default. Typing i will reset the IntraChassis 9000 to the factory default without affecting its IP and Bootstrap configuration.

3

Type y to confirm the reset,

OR type n to cancel the reset.

Note: During the scheduled reset operation, you can see the reset countdown increment by refreshing the screen.

Scheduling a Reset

You can schedule the IntraChassis 9000 to automatically perform a reset from one second up to 24 hours (86,400 seconds) in advance.

To schedule a reset, use the following procedure.

1

Open the Reset Menu by typing r in the Configuration

Menu.

2

Type s to schedule a reset time (within the specified range).

3

Enter the number of seconds the IntraChassis 9000 will wait before it automatically resets.

Important: The maximum number of seconds that can be entered is 86,400 (24 hours).

4

Press Return.

The IntraChassis 9000 will reset automatically after the number of seconds you specified.

Page 3-45

GLXY9.book Page 46 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Viewing the System Log

The IntraChassis 9000 System Log records and displays any major system events on the switch, such as fatal errors, plugging in or removing a module, etc.

To view the system log, use the following procedure.

1

Type l in the Configuration menu. the System Log menu

appears, as shown in Figure 3-27.

IntraChassis 9000 System Log Menu

<Cmd> <Description>

l Display System Log

c

q

Clear System Log

Return to previous menu

Command>

Figure 3-27 System Log menu

2

Type d to display the current system log, as shown in

Figure 3-28.

IntraChassis 9000 System Log Summary

====================================================================

No. D: H: M: S Event

1. 000:00:00:00 Reset NVDB sections to factory default

2. 000:00:00:07 Spanning Tree Task Disabled

3. 000:00:32:53 Spanning Tree Task Enabled

4. 000:00:33:45 Spanning Tree Task Disabled

5. 000:00:41:11 Spanning Tree Task Enabled

6. 000:00:00:00 Reset NVDB section 0 to factory default

7. 000:00:32:51 Spanning Tree Task Disabled

8. 000:00:33:08 Spanning Tree Task Enabled

Quit Next Page

Figure 3-28 System Log Display

The system log displays any major system events that have occurred on the IntraChassis 9000. If no major events have occurred, “System up” messages are displayed.

Note: The system Log holds a maximum of 64 entries.

3

Press any key to display the next page of System Log information.

Page 3-46

GLXY9.book Page 47 Thursday, February 17, 2000 3:04 PM

Viewing the System Log

Clearing the System Log

Use the following procedure to clear all entries from the current System Log.

1

Open the System Log menu by typing l in the Configuration menu.

2

Type c to clear the current System Log.

New entries will begin to accrue as events occur.

Page 3-47

GLXY9.book Page 48 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Viewing Current Operating Information

The IntraChassis 9000 switch’s current operating information can be viewed by accessing the General Information screen within the switch’s Local

Management Interface.

To view the current operating information of the switch:

1

Access the IntraChassis 9000 Local Management Interface.

Note: See Chapter 2, "Installation and Set-up" for instructions on how to connect to the Local Management Interface.

2

Type g in the Local Management Interface Main Menu. A

screen similar to Figure 3-29 appears.

IntraChassis 9000 General Information

System up for: 000days, 21hrs, 45mins, 45secs

Software Version

Bank 1 Image Version/Date: 1.10/Dec 7 1999 12:14:38 (Running)

Bank 2 Image Version/Date: 1.10/Dec 7 1999 11:54:14

System Information

Prom Image Ver/Date:

DRAM Size: 4MB

1.01/Sep 8 1999 15:59:14

Flash Size: 2.0MB

EEPROM Size: 32KB

Administration Information

Console Baud Rate:

System Name: Asante IntraStack Switch

System Location: ZLabs Head Office

9600 bps

System Contact: CLB

System MAC Address, IP Address, Subnet Mask and Router

MAC Address:

IP Address:

00:00:94:8E:F3:7B

192.168.54.240

Subnet Mask:

Router:

255.255.255.0

192.168.54.2

Bootstrap Configuration

Boot Load Mode: LOCAL

Press any key to continue...

Figure 3-29 General Information Screen

Table 3-11 describes each parameter in the General Information screen. To exit

the screen, press any key.

Page 3-48

GLXY9.book Page 49 Thursday, February 17, 2000 3:04 PM

Viewing Current Operating Information

Setting

System Up Time

Bank 1 Image Version/

Date

Bank 2 Image Version/

Date

Prom Image Vers/Date

DRAM Size

EEPROM Size

Flash Size

Console Baud Rate

System Name

System Location

System Contact

MAC Address

IP Address

Subnet Mask

Router

Boot Load Mode

Description

The amount of time the system has been running since last reset or power on.

The version and compilation date of the runtime code that is stored in Bank 1. (Running) indicates code is currently active.

The version and compilation date of the runtime code that is stored in Bank 2.

The version and compilation date of {{what?}}.

The size in megabytes (MB) of the unit’s Dynamic Random

Access Memory.

The size in megabytes (MB) of the unit’s EEPROM.

The size, in MB, of the switch’s flash memory, or non-volatile

RAM.

The current rate which data transfers to the console from the

IntraChassis 9000.

The name assigned to the IntraStack for network purposes.

The physical location of the IntraStack.

Person responsible for configuration of the unit.

The hardware address of the IntraChassis 9000; this address cannot be changed

The unit’s IP (Internet Protocol) address.

The IP subnet mask for the IntraChassis 9000.

The IP address of the default gateway router to which the switch belongs.

The current method in use for loading the switch’s software.

Table 3-11 General Information settings

Page 3-49

GLXY9.book Page 50 Thursday, February 17, 2000 3:04 PM

Basic Configuration

User Interface Configuration

The User Interface Configuration option lets you set the idle time-out periods for both the Console and Telnet user interfaces, and also lets you change the password used for logging in to the configuration menu. Typing u in the

Configuration menu displays the User Interface Configuration menu, as shown

in Figure 3-30.

IntraChassis 9000 User Interface Configuration menu

Console UI Idle Time Out

Telnet UI Idle Time Out

5 min

5 min

Telnet Session Status:

Session Status

1 Active

2

3

4

Inactive

Inactive

Inactive

<Cmnd>

c

t

p

q

Command>

Source IP

192.203.54.240

<none>

<none>

<none>

<Description>

Set Console UI Time Out

Set Telnet UI Time Out

Change Administrator Password

Return to previous menu

Figure 3-30 User Interface Configuration menu

Current Settings

Table 3-12 describes the settings in the UI Time-out Configuration Menu.

Setting Description

Console UI Idle Timeout

Duration of time the Console will remain idle before returning to the main menu.

Telnet UI Idle Time-out Duration of time the console will remain idle before closing the

Telnet connection.

Inactive or Active, depending on whether session is in progress.

Telnet Session Status

Telnet Session Source IP The IP address of the device being used for Telnet Management.

Table 3-12 UI Time-out Settings

Page 3-50

GLXY9.book Page 51 Thursday, February 17, 2000 3:04 PM

User Interface Configuration

Setting Console Idle Time-out Period

Use the following procedure to set the Console Idle Time-out.

1

Type c in the User Interface Configuration Menu.

A prompt for the number of minutes is displayed.

2

Enter the Idle Time-out in minutes at the prompt.

Note: The default time-out is 5 minutes. Range for time-out is 0-60 minutes (0 indicates no time-out).

To exit without making any changes, press ctrl-c.

3

Press Return.

The change of the Console Idle Time-out period is reflected in the User

Interface Configuration menu.

Setting Telnet Idle Time-out Period

Use the following procedure to change the Telnet Time-out.

1

Type t in the User Interface Configuration Menu.

A prompt for the number of minutes is displayed.

2

Enter the Idle Time-out in minutes at the prompt.

Note: The default time-out is 5 minutes. Range for time-out is 1-60. To exit without changes, press ctrl-c.

3

Press Return.

The change of the Telnet Idle Time-out period is reflected in the User Interface

Configuration menu.

After you have configured the desired time-outs, type q to return to the previous menu.

Page 3-51

GLXY9.book Page 52 Thursday, February 17, 2000 3:04 PM

Basic Configuration

Changing the Password

Use this option to change the password that the user must enter to log in to the configuration menu when using either the console or the Web server interface.

Important: The factory default password is Asante. The password is case-sensitive.

To change the current Local Management Interface or Web-based Interface password, use the following procedure.

1

Type p in the User Interface Configuration Menu.

2

Type the password you have been using at the prompt.

3

Type a new password at the “Enter Current Password” prompt.

Important: The password is case-sensitive. The password can be up to a maximum of 20 characters in length. The password characters can be any ASCII code.

4

Press Return.

5

Type the new password again at the confirmation password prompt.

To cancel the change in password, type ctrl-c.

6

Press Return.

The password change takes effect.

7

Type q to return to the Configuration menu.

You will now need to enter the new password each time you log in to the

Configuration menu.

Page 3-52

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

4

Statistics

This chapter describes how to access the statistics for any module in the Galaxy

9000, and how to change your view of those statistics and the counters displayed in it.

Viewing Statistics

Viewing statistics on a regular basis allows you to evaluate your network’s performance. You can view current statistics for the IntraChassis 9000 on a perport basis by accessing the Statistics Menu in the Local Management Interface.

To view statistics use the following procedure.

1

Access the IntraChassis 9000 Local Management Interface, as explained in Chapter 2, “Installation and Set-up”.

2

Type s in the Local Management Interface Main menu. The

System Module Map is displayed, as shown in Figure 4-1.

System Module Map

=================

Please select one of the following slots

Slot Description (Module Type)

---- -------------------------------

1 24 10/100BaseTX ports Module (24-100TX)

2 <none>

3 1000BaseX ports Module (2-GBIC)

4 <none>

5 24 10/100BaseTX ports Module (24-100TX)

6 <none>

7 <none>

8 <none>

Enter Module Number (1-8)>

Figure 4-1 Systems Module Map

3

Select the module for which you want to see statistics. The

Port Statistics Counters screen is displayed, as shown in

Figure 4-2.

Page 4-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Statistics

IntraChassis 9000 Port Statistics Counters Module: 2 Port: 1

Elapsed Time Since Up: 000:00:00:55

<Counter Name> <Total> <Avg./s> <Counter Name> <Total> <Avg./s>

Total RX Pkts

Dropped Pkts

Good Multicast

Oversize Pkts

1474

185

6

0

26

3

0

0

Total RX Bytes 116246 2113

Good Broadcast 57

Undersize Pkts 0

CRC/Align Errors 0

1

0

0

64-Byte Pkts

128-255 Pkts

512-1023 Pkts

283

12

0

5

0

0

65-127 Pkts

256-511 Pkts

1174

5

1024-1518 Pkts 0

21

0

0

<Cmd> <Description> <Cmd> <Description> <Cmd> <Description> r since reset x next module n next port t stop refresh q quit v g prev module select module p s prev port select port

Command>

Figure 4-2 Port Statistics Counters since system up

4

Use the s command to select a port for which you want to see the counters, or use n and p to find the port.

5

Use the g command to select a different module (group) in which you want to select a port, or use x and v to find the module.

6

Type t to stop the periodic updating of the counters, so you can record what they are at that time.

7

Type r to see a display of the same counters, but accrued

since the last reset of the counters as shown in Figure 4-3.

Page 4-2

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM

Viewing Statistics

IntraChassis 9000 Port Statistics Counters Module: 2 Port: 1

Elapsed Time Since Reset: 000:00:00:55

<Counter Name> <Total> <Avg./s> <Counter Name> <Total> <Avg./s>

Total RX Pkts

Dropped Pkts

Good Multicast

Oversize Pkts

1474

185

6

0

26

3

0

0

Total RX Bytes 116246 2113

Good Broadcast 57

Undersize Pkts 0

CRC/Align Errors 0

1

0

0

64-Byte Pkts

128-255 Pkts

512-1023 Pkts

283

12

0

5

0

0

65-127 Pkts

256-511 Pkts

1174

5

1024-1518 Pkts 0

21

0

0

<Cmd> <Description> <Cmd> <Description> <Cmd> <Description> u since system up x next module n next port t stop refresh q quit v g prev module select module p s prev port select port

Command>

Figure 4-3 Port Statistics Counters since reset

8

Type r to in the “since reset” screen reset the statistics counters so you can see them accrue again from zero.

9

Type q to quit either statistics screen and return to the Local

Management System Main Menu.

For definitions of the counters, see Appendix B, "MIB Statistics".

Page 4-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

Statistics

Page 4-4

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

5

Advanced Management

This chapter describes advanced topics for SNMP and RMON management of the IntraChassis 9000, Multicast Traffic Management, and configuration of

Spanning Tree Protocol parameters.

Spanning Tree Protocol

The Spanning Tree Protocol (STP) is a part of the IEEE 802.1D standard that provides for redundancy in a bridged LAN by allowing multiple links between points in the LAN.

Without the use of STP, multiple links in a bridged network will result in bridging loops, which allow excess broadcast traffic which can bring down an entire network.

Overview

The spanning tree protocol reduces a network with multiple, redundant connections to one in which all points are connected (the protocol spans the network), but in which there is only one path between any two points (the paths are branched, as in a tree).

For example, in a large network with multiple paths, the same message will get broadcast over the network through multiple paths, resulting in a great amount of extra network traffic, and possibly, network downtime. This “closed path” or

“bridged loop” among the networks can also start an unending packet-passing process.

Important: To explain STP more effectively, the IntraChassis 9000 is described as a bridge for this section of the manual.

Page 5-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Advanced Management

How It Works

All bridges on the network communicate with each other using special packets called Bridge Protocol Data Units (BPDUs). The information exchanged in the

BPDUs enables bridges on the network to:

❑ Elect a single bridge to be the Root Bridge.

❑ Calculate the shortest path from each bridge to the root.

❑ Select a Designated Bridge on each segment which lies closest to the root, and will forward traffic to the root.

❑ Select a port on each bridge to forward traffic to the root.

Select the ports on each bridge which will forward traffic, and place the redundant ports in blocking state.

Enabling and Disabling STP

The IntraChassis 9000 is shipped with Spanning Tree enabled on all ports. It can be manually enabled or disabled following the instructions below

To enable or disable STP on your IntraChassis 9000, use the following procedure.

1

Type c to open the Configuration Menu.

2

Open the Spanning Tree Configuration Menu by typing s

in the Configuration Menu. See Figure 5-1.

3

Type t to toggle STP to enabled or disabled.

4

If you select disabled, you are prompted to confirm the change.

The STP status is changed. The status is displayed near the top of the Spanning Tree Configuration menu.

Configuring Spanning Tree Parameters

To view the Spanning Tree Configuration menu, as shown in Figure 5-1, type s

in the Configuration menu.

Page 5-2

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM

Spanning Tree Protocol

IntraChassis 9000 Spanning Tree Configuration Menu

STP Status:

Bridge ID:

Enabled

8000 0000948EF37B

Designated Root: 0001 00503EA8B000

Root Port: Module: 3 Port: 8

Root Path Cost: 110

Hello Time: 2 Sec.

Maximum Age: 20 Sec

Forward Delay: 15 Sec.

Bridge Hello Time: 2 Sec.

Bridge Maximum Age: 20 Sec.

Bridge Forward Delay: 15 Sec.

<Cmd>

t

i

h

a

d

p

q

<Description>

Toggle STP Enable/Disable

Set Bridge Priority

Set Bridge Hello Time

Set Bridge Maximum Age

Set Bridge Forward Delay

Spanning Tree Port Configuration

Return to Previous Menu

Command>

Figure 5-1 Spanning Tree Configuration menu

Spanning Tree Parameters

The operation of the Spanning Tree Algorithm is governed by several parameters. You should only attempt to set these parameters if you have experience with the 802.1D specification.

Bridge Priority

Setting the Bridge Priority to a low value will make it more likely that the current bridge will become the root bridge. If the current bridge is located physically near the center of your network, you may wish to decrease the Bridge

Priority from its default value of 0x8000. If the current bridge is near the edge of your network, it is best to leave the value of the Bridge Priority at its default.

Hello Time

This is the time period between BPDUs transmitted by each bridge.

Maximum Age

Each bridge should receive regular configuration BPDUs from the direction of the root bridge. If the Maximum Age timer expires before the bridge receives

Page 5-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

Advanced Management another BPDU, it assumes that a change in the topology has occurred and begins recalculating the spanning tree.

Forward Delay

The Forward Delay parameter regulates the delay before each port begins transmitting traffic after a recalculation of the spanning tree. If a port begins forwarding traffic too soon, the network can be adversely affected. The permitted range of the Forward Delay is 4 to 30 seconds.

Note: The Hello Time, Maximum Age, and Forward Delay are constrained by the following formula:

(Hello Time + 1) <= Maximum Age <= 2 x (Forward Delay -1)

In general, reducing the values of these timers will make the spanning tree react faster in the case of changes in the topology, but may cause temporary loops as the tree stabilizes in a new configuration. Lengthening the timers will make the tree react more slowly to changes in configuration but will make an unintended reconfiguration less likely. All of the bridges in the tree must agree on the values of these timers, so each bridge uses the ones advertised by the root.

Port Priority

If two ports are connected to the same segment, the manager can affect the probability that either one will be chosen for inclusion in the tree by changing this value.

Page 5-4

GLXY9.book Page 5 Thursday, February 17, 2000 3:04 PM

Spanning Tree Protocol

Current STP Settings

The following settings are displayed in the Spanning Tree Port Configuration

menu screen, as shown in Figure 5-2.

Setting

STP Status

Bridge ID

Designated Root

Root Port

Root Path Cost

Hello Time

Maximum Age

Forward Delay

Bridge Hello Time

Bridge Maximum Age

Bridge Forward Delay

Description

Whether spanning tree protocol is currently enabled or disabled.

The Bridge Identifier of this bridge. The first part of the Bridge ID is the Bridge Priority. (If the Bridge ID is shown as 8000

000094EE5080, the 8000 is the Bridge Priority. The remainder is the MAC address of this bridge, which cannot be changed.).

The Bridge Identifier of the bridge that is currently the root bridge for the spanning tree.

The port this bridge will use to forward traffic to the root. If this bridge is the root, the root port will be 0.

The cost as calculated by the spanning tree for messages to reach the root. If this bridge is the root, the cost will be 0.

The value of the timer currently being used by the bridge.

The value of the maximum age timer currently being used.

The value of the forward delay timer currently being used.

The value that will be used by the spanning tree if this bridge becomes the root bridge.

The value that will be used by the spanning tree if this bridge becomes the root bridge.

The value that will be used by the spanning tree if this bridge becomes the root bridge.

Spanning Tree Port Configuration

To set the Port Priority and Port Path Cost values for STP, access the Spanning

Tree Port Configuration menu shown in Figure 5-2 by typing p in the Spanning

Tree Configuration menu.

Page 5-5

GLXY9.book Page 6 Thursday, February 17, 2000 3:04 PM

Advanced Management

IntraChassis 9000 Spanning Tree Port Config. Menu Module Type: (24-

100TX)

Module: [1]

Port: [1]

Port Speed:

Port Status:

Port State:

100 Mbps

Enabled

Forwarding

Port MAC Address: 00:00:93:8F:E3:7C

Port Priority: 0x80

Port Path Cost: 10

<Cmd>

i

c

q

<Description>

Set Port Priority

Set Port Path Cost

Return to Previous Menu

Command>

Figure 5-2 Spanning Tree Port Configuration menu

Setting Port Priority and Path Cost

Use the following procedure to set the STP Port Priority and Path Cost values.

The port priority is a Bridge Spanning Tree parameter that ranks each port.

When 2 or more ports have the same path cost, the STP selects the path with the highest priority (lowest numerical value). By changing the priority of a port, you can make it more or less likely to become the root port. The default value is

128, and the range is 0-255.

Port path cost is the Bridge Spanning Tree parameter that assigns a cost factor to the port. The lower the assigned port path cost, the more likely the port is to be accessed. The default value is a result of the equation path cost = 1000/LAN speed (in Mbps)

Thus, for 10Mbps ports, the assigned default port path cost is 100, for

100Mbps ports the default port path cost is 10, and for 1000Mbps ports, the assigned default port path cost is 1. The range is 1-65,535.

1

Access the Spanning Tree Port Configuration menu by typing p in the Spanning Tree Configuration menu.

2

Use the m, x, and v commands to select the module with the port you want to configure.

3

Use the s, n, and p commands to select the port you want to

Page 5-6

GLXY9.book Page 7 Thursday, February 17, 2000 3:04 PM

SNMP and RMON Management configure.

4

Type i to set the Port Priority.

Type c to set the Port Path Cost.

5

Enter a value for the setting you are making.

6

Press Return.

The new Port Priority or Port Path Cost is displayed in the Spanning Tree Port

Configuration menu.

SNMP and RMON Management

The SNMP (Simple Network Management Protocol) may be used to manage the IntraChassis 9000. The SNMP agent supports database objects that are defined in the following management information bases (MIBs):

❑ MIB II (RFC 1213)

❑ Bridge MIB (RFC 1493)

❑ RMON (RFC 1757) 4 groups - Ethernet Statistics, Ethernet History,

Alarm, and Events (See next section for details)

Private IntraChassis 9000 MIB

Any SNMP-based network management application can be used to manage the

IntraChassis 9000. Refer to your SNMP software manual for information on management of switches.

For details on console-based SNMP settings, see “SNMP Configuration” in

Chapter 3.

RMON Management

Remote Network Monitoring allows the network manager to gather data on the network’s traffic for future retrieval. RMON is an Internet Standard defined in

RFC1757.

Using RMON, a network monitor (also called a probe) listens to traffic on the network and gathers statistics which may be retrieved later by a network management station using the Simple Network Management Protocol (SNMP) as described in the previous section. The four groups of RMON that are supported by the IntraChassis 9000 are described in the following sub-sections.

Page 5-7

GLXY9.book Page 8 Thursday, February 17, 2000 3:04 PM

Advanced Management

Ethernet Statistics Group

This group contains statistics measured on each port of the IntraChassis 9000.

These are cumulative counters which start at zero each time the IntraChassis

9000 is reset. The Statistics Group is automatically implemented by the

IntraChassis 9000.

Ethernet History Group

This group records periodic statistical samples from ports on the IntraChassis

9000 and stores them for later retrieval. A network manager can use the data to analyze how network traffic has varied over a period of time.

Alarm Group

This group takes periodic statistical samples from variables in the IntraChassis

9000 and compares them to previously configured thresholds. If the monitored variable crosses a threshold, an event is generated.

Event Group

This group controls the generation and notification of events from the

IntraChassis 9000. The Alarm and Event groups together allow the network manager to configure RMON so that if a particular statistic such as the number of bad frames goes higher than a certain level, the IntraChassis 9000 will send a trap to its configured trap receivers, notifying the manager of the event. For

information on configuring trap receivers, see “SNMP Configuration” in

Chapter 3.

The IntraChassis 9000 switches provide control of the RMON groups only through SNMP. Please see the documentation for your SNMP management application for information.

For more information about RMON, please see RFC1757, “Remote Network

Monitoring Management Information Base”, available from the FTP site listed in Appendix A.

Security

There are three security options you can use on ports of the IntraChassis 9000.

These are duplicated IP detection/trapping, station movement trapping, and new node trapping.

Page 5-8

GLXY9.book Page 9 Thursday, February 17, 2000 3:04 PM

Security

You can designate a device as a trap receiver as explained in "Adding or

Updating a Trap Receiver" in the "SNMP Configuration" section of Chapter 3.

This receiver device will get the following information from the specified traps.

Trap

Information shown:

Duplicated IP

MAC addresses of both stations using

IP address; number of port(s) on switch

Station Movement

Station’s MAC address and

IP address (if available); number of port

New Node

Intruder’s MAC address and IP address (if available); number of port

Table 5-1 Security Traps

The following subsections describe each of the three security options in detail.

Duplicated IP Detection/Trap

These two security measures allow you to set up detection and the sending of a trap (alert) for the use of a single IP address by two stations. If you enable

Duplicated IP detection, the switch starts monitoring the broadcast ARP

(Address Resolution Protocol) traffic from all of its ports, to detect duplicated

IP address conditions. If you enable detection and the sending of a trap, then the designated trap receiver will get an alert each time a duplicated IP address is used on the system.

Note: In order to send Duplicated IP traps, Duplicated IP detection must be enabled.

Page 5-9

GLXY9.book Page 10 Thursday, February 17, 2000 3:04 PM

Advanced Management

Station Movement Trap

This security measure ensures that when any end station is moved from one switch port to another, an alert (Station Movement Trap) will be sent to the designated trap receiver. The information displayed in the alert is listed in

Table 5-1. The station movement is detected when the station’s MAC address

(already learned by the switch) appears on a different switchboard.

New Node Detection Trap

This security measure ensures that when any new device is connected to the secured port, an alert (New Node Detection Trap) will be sent to the designated

trap receiver. The information shown in the alert is listed in Table 5-1. The new

device is detected when it is connected and its MAC address is recognized as one not present in the current table.

Once a device has been connected and has generated traffic on the network, the trap will not be re-sent. If the switch ages out the MAC address of a connected device from its forwarding database, new traffic from that device will result in a

New Node trap being sent. The default age-out time is 300 seconds. You may reduce the number of traps sent by lengthening the age-out time, as explained

in "Setting the MAC Address Age-Out Time" in Chapter 3.

Enabling and Disabling Duplicated-IP Detection

To enable or disable detection of duplicated IP addresses, access the Security

Management menu by typing t in the Configuration menu. Then type d to toggle Duplicated-IP detection from enabled to disabled, or disabled to enabled. By default, Duplicated-IP detection is enabled.

Enabling and Disabling Duplicated-IP Trap

To enable or disable the sending of a trap when a Duplicated-IP is detected, first enable Duplicated-IP detection as explained in the previous section. Then type i in the Security Management menu to toggle Duplicated-IP Trap from enabled to disabled, or disabled to enabled. By default, Duplicated-IP Trap is enabled.

Enabling and Disabling Station Movement Trap

To enable or disable detection of the movement of a station on the IntraChassis

9000, access the Security Management menu by typing t in the Configuration menu. Then type s to toggle the Station Movement Trap from enabled to disabled, or disabled to enabled. By default, the Station Movement Trap is disabled.

Page 5-10

GLXY9.book Page 11 Thursday, February 17, 2000 3:04 PM

VLAN Management

Enabling and Disabling New Node Detection Trap

To enable or disable detection of a new node on the system, access the Security

Management menu by typing t in the Configuration menu. Then type n to toggle New Node detection from enabled to disabled, or disabled to enabled.

By default, New Node detection is disabled {right?}.

Viewing a List of Duplicated-IP Addresses

To see a list of duplicated IP addresses that have been detected at the

IntraChassis 9000, type l in the Security Management menu. A screen appears,

similar to Figure 5-3.

Duplicated-IP List

+--------------+-----------------+-+-+-----------------+-+-+

| IP Address | Owner MAC |M|P| Spoofer MAC |M|P|

+--------------+-----------------+-+-+-----------------+-+-+

192.203.54.222 00:00:94:00:00:01 1 1 00:00:94:00:00:02 1 2

192.203.54.223 00:00:94:00:00:04 1 3 00:00:94:00:00:02 1 2

192.203.54.224 00:00:94:00:00:05 1 4 00:00:94:00:00:02 1 2

Press <q> to Quit, or, press any key to continue...

Figure 5-3 List of Duplicated-IP Addresses

Resetting Security to Defaults

To reset the security measures on the IntraChassis 9000 to the factory defaults, access the Security Management menu by typing t in the Configuration menu.

Then type r to reset all of the security configurations that have been changed back to the factory-set defaults. These defaults and their meanings are discussed in the sections on each security measure, earlier in this chapter.

VLAN Management

A virtual LAN, or VLAN, is a logical segmentation/grouping that allows stations/users to communicate as if they were physically connected to a single

LAN, independent of physical configuration of the network. Though a VLAN

Page 5-11

GLXY9.book Page 12 Thursday, February 17, 2000 3:04 PM

Advanced Management group presents to the user a picture of connection to a single LAN, it is different from a LAN in the sense that it localizes the broadcast, multicast, and flooded traffic to parts of LAN segments, rather than to the whole LAN. In essence, a

VLAN segment/group can be considered the Layer-2 broadcast segment equivalent of a Layer-3 network.

The real need for VLANs in traditional Layer-2 bridges and switches arises from their use of a basic flooding mechanism which results in unnecessary flooding traffic (broadcast, multicast, and unknown destination traffic) that causes clogging and band-width wastage in a LAN. As today’s networks expand rapidly, the Layer-2 flooding problem can become a bottleneck.

The present-day technology provides various means of controlling these flooding traffic problems, which mainly include deployment of Layer-3 devices that provide broadcast firewalls. Other methods include IP multicast control, customized packet filtering, etc. It is evident that these solutions press the requirement for Layer-3 routers. As all of us know, more and more deployment of legacy routers increases the latency of traffic forwarding and eventually degrades network performance. Also, the cost of maintenance increases and configuration becomes more complex with more Layer-3 devices.

In contrast, VLAN technology offers a simple and efficient solution that enhances the network performance, bandwidth utilization, and more importantly, network security, by localizing the broadcast, multicast, and unicast flooding traffic.

Port based VLANs provide one of the many VLAN approaches that solve the problem of unnecessary flooding. They allow ports to be grouped in VLAN segments, so as to limit the transmission of incoming broadcast, multicast, and unknown destination address frames in a VLAN segment to only those ports that are grouped in that segment. This grouping produces selective flooding, rather than flooding to all ports in the system. This, in turn, greatly reduces the unnecessary flooding traffic in a network.

Other VLAN approaches include MAC-based VLANs and policy-based

VLANs. The present version of the IntraChassis 9000 supports port-based

VLANs in compliance with IEEE P802.1Q/Draft 8 standards. The following sections of the chapter describe the concepts and details needed to configure and manage VLANs on Intrachassis switches.

VLAN Specifications for the IntraChassis 9000

The present IntraChassis 9000 supports the following IEE P802.1Q features:

Page 5-12

GLXY9.book Page 13 Thursday, February 17, 2000 3:04 PM

VLAN Management

❑ Up to 64 Manually Configurable VLANs

❑ Default VLAN

❑ VLAN creation and deletion

❑ VLAN port member addition and deletion

VLAN untagged set addition and deletion

❑ Configurable VID range: 2 - 4094

Port VID configurable range: 1 - 4094

❑ Port Ingress Filtering

Port Admit Frame Type

❑ Independent VLAN learning (IVL)

Shared VLAN learning (SVL)

❑ GVRP for dynamic VLAN learning (to be supported; later versions)

Single STP (Spanning Tree Protocol) spanning multiple VLANs

❑ SNMP based VLAN management

Page 5-13

GLXY9.book Page 14 Thursday, February 17, 2000 3:04 PM

Advanced Management

Other VLAN Features in IntraChassis 9000

❑ VLAN management security

VLAN MAC address insertion and removal

❑ Console UI management of VLANs

Web interface management of VLANs

The subsections following the Abbreviations below describe these features and how each is configured.

Abbreviations

The following abbreviations are used throughout this chapter.

GARP:

GVRP

General Attribute Registration Protocol

GARP VLAN Registration Protocol

MGMT:

PVID:

Management.

A tagged port’s VLAN ID. Range is 1…4094.

STP: Spanning tree protocol.

Tagged Frame: Frame with 802.1Q VLAN Tag header.

Untagged Frame: Frame either without 802.1Q VLAN Tag header, or with this header and with VID = 0.

VID: VLAN ID in the range of 1…4095.

Note: The terms “groups” and “segments” are both used to represent VLAN segments in the system. They are numbered from 1 to 64. VLAN Groups

The IntraChassis 9000 supports 64 manually configurable VLAN Groups. A

VLAN group is uniquely identified by a 12-bit (1-4095) VLAN ID (VID). No two VLAN Groups can have the same VID if they reside on the same switch.

Each VLAN group has a portmap that specifies the port members of the VLAN and a set of untagged ports, which specifies the port members of the VLAN group that transmit only VLAN untagged frames. The untagged set can be a subset of the portmap, or it can be the same as the portmap, but it cannot have ports that are not part of the portmap. If a port is in the VLAN portmap and not in the VLAN untagged set, then the port transmits tagged frames only. A

VLAN group can be shared with other VLAN groups for MAC address learning purposes.

Page 5-14

GLXY9.book Page 15 Thursday, February 17, 2000 3:04 PM

VLAN Management

The management operations allowed on a VLAN group are:

❑ Creation

❑ Deletion

❑ Name configuration.

VID Change configuration.

❑ Adding and deleting port members

Adding and deleting untagged sets

❑ Sharing and unsharing VLANs

Inserting and removing MAC addresses

❑ Toggling Management Access

Default VLAN

As per IEEP802.1Q specifications, the only VLAN that exists by default in the

IntraChassis 9000 is the default VLAN, with VID = 1, and all ports as its members. Also, all ports belong to the default VLAN’s untagged set. The following table summarizes the Default VLAN configuration in the

IntraChassis 9000.

Default VLAN Information

Name: Default VLAN

VID: 1

Port Members: All ports

Untagged Set: All Ports

Port PVID: 1 for all Ports

Management Access: Enabled

Operations Allowed for Default VLAN

Creation/Deletion: Not allowed

Set VLAN Name: Allowed

Change VID: Not allowed

Port member Addition/Deletion: Allowed

Untagged member Addition/Deletion: Allowed

MAC address Insertion/Removal: Allowed

Toggle Management Access: Allowed

Share/Unshare VLAN: Allowed

Table 5-2 Default VLAN information and operations

Port VLAN ID

Port VLAN ID or PVID is used for VLAN classification of incoming untagged frames and has meaning only when a port is configured to receive both untagged and tagged frames. The untagged frames get classified to the VLAN represented by the PVID of the ingress port and the tagged frames get classified to the VLAN represented by the VID carried in the tag header of the received

Page 5-15

GLXY9.book Page 16 Thursday, February 17, 2000 3:04 PM

Advanced Management frame. Ports should have a non-zero VID associated with them. By default, the

PVID of all ports is 1, in compliance with IEE P802.1Q specifications. The allowed PVID range is 1-4094. The PVID of 4095 is assigned to ports that are

configured to receive only 802.1Q tagged frames. See the “Port Admit Frame

Type” section for details.

Port Admit Frame Type

All ports are set by default to receive both 802.1Q VLAN tagged frames and untagged frames. According to IEEE P802.1Q, a port should be configurable to admit only 802.1Q VLAN tagged frames. Untagged frames are filtered unconditionally on the ports that are set to admit only 802.1Q tagged frames; the source MAC addresses of the incoming untagged frames are not learned either. When a port is set to receive only 802.1Q tagged frames, it’s PVID has no meaning, and is therefore assigned the value of 4095. Incoming tagged frames are classified to the VLAN represented by the VID in the tag header of

the frame. See the “Port Ingress Filtering” section for more information about

forwarding and filtering of received tagged frames.

This feature is helpful in setting up Intra Switch Link (ISL) configuration.

{need more information}

Port Ingress Filtering

This feature controls the learning and filtering behavior of the ports for which there are incoming untagged and tagged frames. If a port’s ingress filtering is disabled, the learning of incoming source addresses and the forwarding of untagged and tagged frames happens in the switch regardless of whether the ingress port is a member of the incoming frame’s VLAN classification or not.

But when ingress filtering is enabled, incoming untagged and tagged frames are filtered unconditionally, as long as the ingress port is not a member of the frame’s VLAN classification. There is also no learning of the source address.

This feature is helpful in setting up Intra Switch Link (ISL) configuration.

{{need more information}}

VLAN Port Membership and Untagging

Port members can be added to and deleted from a VLAN Group. This operation is mainly useful in defining the configuration discussed in the {cf

IVL/SVL} section. When you add a port member to a VLAN, it is added to the untagged set by default; this means the frames sent out on this port will be untagged. To change the egress frame type, the port has to be deleted from the

Page 5-16

GLXY9.book Page 17 Thursday, February 17, 2000 3:04 PM

VLAN Management

VLAN untagged set. Deleting a port from the untagged set means that the port is still a member of this VLAN, but it can transmit tagged frames only. Ports can be added to the untagged set of a VLAN group. When added to the untagged set, the port is added to the VLAN’s port member set also. So in essence, a port in a VLAN can transmit either tagged or untagged frames, depending on its association with the VLAN’s untagged set. No port can transmit both tagged and untagged frames on the same VLAN.

Page 5-17

GLXY9.book Page 18 Thursday, February 17, 2000 3:04 PM

Advanced Management

Page 5-18

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

6

Web Browser Management

This chapter tells how to manage the IntraChassis 9000 by means of a Web browser, using Web pages to monitor and configure the switch.

Accessing with a Web Browser

This section explains how to access the HTTP server and view the management features it offers. To use Web browser management, the IntraChassis must be configured with an IP address. See “Configuring for Management” in Chapter

2 for instructions.

1

Locate a computer with a functioning World Wide Web browser and open the browser.

2

Type the Switch IP address at the URL prompt.

3

Enter user name IntraChassis and a password. The default password is Asante.

4

Press Return. The Switch Web Browser Management Over-

view Page appears, as shown in Figure 6-1.

Note: The browser pages shown in this chapter are typical of those used for the IntraChassis and settings are given only as examples. The user must configure the

IntraChassis with parameters that are specific to the user’s application and site requirements.

Page 6-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Figure 6-1 Web Browser Overview Page

The Switch Web Browser Overview Page contains a sidebar with nine management option buttons, and a view of the IntraChassis front panel that displays real-time IntraChassis 9000 operating information.

Management Buttons

The left sidebar frame buttons provide the following options:

Front Panel

❑ Genl Info (General Information)

Statistics

❑ Port Config (Port Configuration)

Span Tree (Spanning Tree Protocol Configuration)

Page 6-2

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM

Front Panel Button

❑ SNMP (Simple Network Management Protocol)

❑ Addr Table (IP/MAC Address Table)

❑ VLAN (Virtual LAN Configuration)

❑ Duplicate IP (Duplicate IP Trap Log)

The following sections describe and explain the pages that are displayed when you click each of the buttons.

Front Panel Button

This button opens (or refreshes) the IntraChassis Web Browser Management

Page. This is the top-level or opening page. It contains the following elements.

Front Panel display

The front panel graphic displays the image of the connected switch, its LED panel, and the active data ports.

The front panel LED display simulates the IntraChassis in real-time operating mode. It approximates all switch activity as it occurs.

Page 6-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Port Selector Feature

If you point the cursor to a port connector and click the mouse, a port-specific page is displayed, which shows the selected port’s configuration and traffic statistics.

Page 6-4

Figure 6-2 Port configuration and statistics page

GLXY9.book Page 5 Thursday, February 17, 2000 3:04 PM

Genl Info (General Information) Button

Genl Info (General Information) Button

This button opens the IntraChassis’s General Information page. The page has

seven sub-levels, as shown in Figure 6-3. The General Information fields are

described fully in "Viewing Current Operating Information" in Chapter 3.

Figure 6-3 General Information page

The first two sub-levels, Software Version and Administrative Information, are displayed on the opening page. To view the other sub-levels, click the links for them at the top of the General Information page.

Page 6-5

GLXY9.book Page 6 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Statistics Button

This button opens the Statistics page, which presents a graphical image of the

IntraChassis statistics, as shown in Figure 6-4. On this page, the user can view

system statistics since the last system reset. See "Viewing Statistics" in Chapter 4

for a description of the statistics counters.

Figure 6-4 Statistics - Bar Chart

The following features allow you to modify the statics bar chart.

Up-Down Arrows – The left-most up and down arrows let you scroll the screen up to view the counter graph, when the counters have run off the screen due to the system having been up for a long time.

❑ Right-Left Arrows - These arrows beneath the Bar Chart let you view the statistics for different ports on the same module (if the Port radio button is selected) or ports in different modules (if the Module radio button is selected).

❑ Since Up Button – Brings up a graph of the total packets/bytes switched on the ports since the switch was last reset or powered on.

❑ Rate Button – Displays the rate of the packets or bytes per port.

❑ Since Rst – Displays the packets/bytes switched since the management counters were last reset or cleared.

Page 6-6

GLXY9.book Page 7 Thursday, February 17, 2000 3:04 PM

Statistics Button

❑ Reset – Clears the counters for future samplings.

❑ Counters – Displays the statistical counters of the associated view,

since up or since reset, a shown in Figure 6-6 and Figure 6-7.

Note: You may also view a summary of the frames per port by placing the cursor on the desired bar. A box with the statistics appears, as shown in

To see either a line graph or a table display of the system’s statistics, click on a bar, then choose the option you want from the pop-up menu at the top of the

Statistics page, and click Apply. {{right?}}

In Figure 6-5 the Received Frames statistics for a single port are displayed in a

line graph.

Figure 6-5 Line Chart of received frames for a port

In Figure 6-6, a summary of the counters for a port is displayed in table format.

Page 6-7

GLXY9.book Page 8 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Figure 6-6 Summary of counters for a port

In Figure 6-7 the counters for a port are displayed in bar graph form.

Page 6-8

Figure 6-7 Bar Graph of counters for a port

GLXY9.book Page 9 Thursday, February 17, 2000 3:04 PM

Port Config (Port Configuration) Button

Port Config (Port Configuration) Button

This button opens the Port Configuration page, which provides a comprehensive overview of the status of each port on the IntraChassis, as shown

in Figure 6-8. The configuration page for any individual port can be accessed by

single clicking on the associated blue number in the right or left hand margin.

Figure 6-8 Port Configuration table

To view the Port Configuration table for the ports of a different module, click

on the module number link at the top of the table. For example in Figure 6-8,

you could see the table for the ports in Module 2 by clicking on the Module 2 link at the top of the table.

Page 6-9

GLXY9.book Page 10 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Span Tree (Spanning Tree) Button

This button opens the Spanning Tree Protocol (STP) Configuration page,

which shows the STP Configuration of the IntraChassis, as shown in Figure 6-

9. STP configuration is explained in Chapter 5, Advanced Management. Click

the STP Port Configuration button to display the STP Configuration settings for each port.

Figure 6-9 Spanning Tree Configuration page

Important: Do NOT configure any STP parameters unless you have knowledge of and experience with the IEEE

802.1d specification.

Page 6-10

GLXY9.book Page 11 Thursday, February 17, 2000 3:04 PM

SNMP Button

SNMP Button

This button displays the SNMP (Simple Network Management Protocol) page,

as shown in Figure 6-10. See “SNMP Configuration” in Chapter 3 for an

explanation of SNMP settings.

Figure 6-10 SNMP Configuration page

Page 6-11

GLXY9.book Page 12 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Addr (Address) Table Button

The Addr Table button opens the MAC and IP Address Table page, which

displays two tables, as shown in Figure 6-11. The top table displays the counts

of IP and MAC addresses for each port. The lower table displays IP and MAC addresses for either a particular port, or All ports. The display for all ports is

shown in Figure 6-11. The activity status (Entry) and VLAN segment (VSEG)

are also displayed for each device.

Figure 6-11 IP and MAC Address Table page

To see the MAC and IP addresses, the activity status, and the VLAN segment for the devices connected to a particular port, click the port’s number in the top table. Use the Search boxes to search for either an IP or MAC address on the

IntraChassis.

Page 6-12

GLXY9.book Page 13 Thursday, February 17, 2000 3:04 PM

VLAN Button

VLAN Button

This button opens the VLAN Port Selection page, as shown in Figure 6-12. The

page shows the modules of the IntraChassis 9000. There is also a panel indicating the current Port VLAN ID and its settings. For information on

VLANs, see Chapter 5.

Figure 6-12 VLAN Port Selection page

To see the PVID and settings for a port, click on the connector for it in the module simulation. To see the options for VLAN Group Configuration, {{Do

What?}}.

Page 6-13

GLXY9.book Page 14 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Figure 6-13 VLAN Group Configuration options

To add or delete MAC addresses for devices connected to the IntraChassis

9000, click the Add/Del MAC Addr button in the VLAN Group

Configuration dialog box. The dialog box shown in Figure 6-14 appears.

Figure 6-14 Add/Delete MAC Address dialog box

When you have added or deleted the MAC address, the VLAN Group

Configuration page is displayed again.

Page 6-14

GLXY9.book Page 15 Thursday, February 17, 2000 3:04 PM

VLAN Button

To create or modify the basic attributes of a VLAN group, click the button for the option in the VLAN Group Configuration dialog box. {{right?}} The VLAN

Attributes dialog box is displayed, as shown in Figure 6-15.

Figure 6-15 VLAN Attributes dialog box

Enter or change the basic attributes, then click OK.

To see advanced management options for the current VLAN {{do what?}}

The Advanced VLAN Management dialog box is displayed, as shown in

Figure 6-16.

Page 6-15

GLXY9.book Page 16 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Figure 6-16 Advanced VLAN Management dialog box

Select the port you want to manage, and click the appropriate radio button to move the port, or to add or delete members from it.

Page 6-16

GLXY9.book Page 17 Thursday, February 17, 2000 3:04 PM

Duplicate IP Button

Duplicate IP Button

This button lights up if a duplicate IP number has been detected on the system.

If you click the button, it opens the Duplicate IP Trap Log page, which, if the trap is enabled, displays a record of duplicate IP Addresses detected. The Log shows the MAC address of the device that is the original or rightful owner of the IP address, and the MAC address of the spoofer device that is using a copy of the IP address.

Figure 6-17 Duplicate IP Trap Log page

For more information on enabling the Duplicate IP trap, see "Enabling and

Disabling Duplicated-IP Trap" in Chapter 5.

Page 6-17

GLXY9.book Page 18 Thursday, February 17, 2000 3:04 PM

Web Browser Management

Page 6-18

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

A

Technical Support

Contacting Technical Support

To contact Asanté Technical Support:

Telephone

Fax

Fax-Back

E-mail

(800) 622-7464

(801) 566-3787

(800) 741-8607 [email protected]

World Wide Web Site http://www.asante.com

FTP site for RMON information <ftp://ftp.isi.edu/in-notes/rfc1757.txt>

Technical Support Hours

6:00 a.m. to 5:00 p.m. Pacific Standard Time USA, Monday - Friday.

Page A-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

GLXY9.book Page 1 Thursday, February 17, 2000 3:04 PM

B

MIB Statistics

MIB Object Definitions for Counters

The following MIB objects are those for which counters are displayed in the

Statistics Counters screens shown in both the console and Web interface. The definitions and references are quoted from RFC 1516.

Readable Frames

"This object is the number of frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std,

4.4.2.1) and for which the FCSError and CollisionEvent signals are not asserted.

This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableFrames

Readable Octets

"This object is the number of octets contained in valid frames that have been received on this port. This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame

(i.e., including FCS octets but excluding framing bits and dribble bits).

This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableOctets

FCS Errors

"This counter is incremented by one for each frame received on this port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).

The approximate minimum time for rollover of this counter is 80 hours."

Page B-1

GLXY9.book Page 2 Thursday, February 17, 2000 3:04 PM

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aFrameCheckSequenceErrors

Alignment Errors

"This counter is incremented by one for each frame received on this port with the FCSError and FramingError signals asserted and CollisionEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1). If rptrMonitorPortAlignmentErrors is incremented then the rptrMonitorPortFCSErrors Counter shall not be incremented for the same frame.

The approximate minimum time for rollover of this counter is 80 hours."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aAlignmentErrors

Frame Too Longs

"This counter is incremented by one for each frame received on this port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3

Std). If rptrMonitorPortFrameTooLongs is incremented then neither the rptrMonitorPortAlignmentErrors nor the rptrMonitorPortFCSErrors counter shall be incremented for the frame.

The approximate minimum time for rollover of this counter is 61 days."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aFramesTooLong

Short Events

"This counter is incremented by one for each CarrierEvent on this port with

ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine.

Note: shortEvents may indicate externally generated noise hits which will cause the repeater to transmit Runts to its other ports, or propagate a collision

(which may be late) back to the transmitting DTE and damaged frames to the rest of the network.

Implementors may wish to consider selecting the ShortEventMaxTime towards the lower end of the allowed tolerance range to accommodate bit

GLXY9.book Page 3 Thursday, February 17, 2000 3:04 PM losses suffered through physical channel devices not budgeted for within this standard.

The approximate minimum time for rollover of this counter is 16 hours."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aShortEvents

Runts

"This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than

ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than

ShortEventMaxTime and the CollisionEvent signal is deasserted.

ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times.

An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt.

ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine.

Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of collision fragments may exceed ValidPacketMinTime.

The approximate minimum time for rollover of this counter is 16 hours."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts

Collisions

"This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on this port is also asserted.

The approximate minimum time for rollover of this counter is 16 hours."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aCollisions

Late Events

"This counter is incremented by one for each CarrierEvent on this port in which the CollIn(X) variable transitions to the value SQE (Ref: 9.6.6.2, IEEE

Page B-3

GLXY9.book Page 4 Thursday, February 17, 2000 3:04 PM

802.3 Std) while the ActivityDuration is greater than the LateEventThreshold.

Such a CarrierEvent is counted twice, as both a collision and as a lateEvent.

The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the

LateEventThreshold and ValidPacketMinTime threshold.

The approximate minimum time for rollover of this counter is 81 hours."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aLateEvents

Very Long Events

"This counter is incremented by one for each CarrierEvent on this port whose

ActivityDuration is greater than the MAU Jabber Lockup Protection timer

TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).

Other counters may be incremented as appropriate." Reference: IEEE 802.3

Rptr Mgt, 19.2.6.2, aVeryLongEvents

D.R. Mismatches

"This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency.

The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing.

When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented, at the implementor's discretion.

Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard."

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aDataRateMismatches

Auto Partitions

"This counter is incremented by one for each time the repeater has automatically partitioned this port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here."

Page B-4

GLXY9.book Page 5 Thursday, February 17, 2000 3:04 PM

Reference: IEEE 802.3 Rptr Mgt, 19.2.6.2, aAutoPartitions

Total Errors

"The total number of errors which have occurred on this port. This counter is the summation of the values of other error counters (for the same port), namely: rptrMonitorPortFCSErrors, rptrMonitorPortAlignmentErrors, rptrMonitorPortFrameTooLongs, rptrMonitorPortShortEvents, rptrMonitorPortLateEvents, rptrMonitorPortVeryLongEvents, and rptrMonitorPortDataRateMismatches.

This counter is redundant in the sense that it is the summation of information already available through other objects. However, it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters."

Page B-5