- Home
- Home security & automation
- Security device components
- Campbell Scientific
- Vaisala HMP35A and HMP35D Operating
- Owner's manual
Campbell Scientific Vaisala and HMP35D Vaisala HMP35A and HMP35D Operating Operating Manual
Add to My manualsadvertisement
◉
Touch to zoom
Operating Manuel instructions d'utilisation Bedienungsanleitung Kaytt6ohje HMP 35A & HMP 350 Humidity and temperature probes Sondes de mesure de temperature et d'humidite Mel"Ssonden fur Feuchte und Temperatur Kosteus- ja lamp6tila- mittapaat Doc. no. HMP35A-OO217-2.1 ~+} VftlSftLft SENSORSYSTEMS Weak more often, depending on the conditions of use and desired accuracy. A one-point calibration may be performed for the probes during actual measurement by adjusting the trimmer potentiometer marked "DRY" in the probe shaft. The field calibration can be performed against a calibrated Vaisala humidity meter. For a highaccuracy two-point calibration use a Vaisala HMK 11 calibrator and saturated salt solutions as described in the HMK 11 Operating Manual. The calibration is first done for the dry end and then for the wet end by adjusting trimmer potentiometers marked "DRY" and "WET". The potentiometers are located under a protective plug in the probe handle, see Figure 3. (Note: the minimum output signal of 0.002 V corresponds to a relative humidity Replacing of 0.2 %RH.) the H-sensor Detach the damaged sensor and replace it with a new one. Handle the sensor with care. Calibrate the probe, preferably using two-point calibration, before taking it into use. Chemical tolerances of the H-sensor Long-term exposure of the sensor to certain chemicals and gases may shorten sensor life and change its properties. The following list give suggested maximum ambient concentrations for some typical chemicals: 1. Organic solvents 2 Aggressive chemicals (e.g. strong acids such as S02' H2SO4' H2S, HCI, C12, etc.) acids 3, 4. Bases 1000...10000 ppm (typ.) 1...10 ppm (typ.) 100...1000 ppm (typ.) 10000...100000 ppm (typ. Detailed information on allowed concentrations is available on request from your Vaisala representative. 2 4. HMK 5. HMP 00 SPARE PARTS AND ACCESSORIES 11 calibrator Radiation shield HMP 35A HUMICAP@ H-sensor Temperature sensor Pt 100 (1/3 DIN 43760B) Membrane filter Sintered filter 37 ~m Sintered filter 216 ~m Plastic grid 0062 10429 2787 6685 6686 6597 HMP 35D HUMICAP@ H-sensor Temperature sensor Pt 100 (1/3 DIN 437608) Membrane filter, chromium-plated Sintered filter 37 ~m Sintered filter 216 ~m 0062 10429 16126 6685 6686 TECHNICAL SPECIFICATIONS 35A & HMP 35D Measurement range Output signal range 0 ...100 0.002 ...1 %RH VDC (equals 0.2 ...1 Accuracy % RH) at +20 °C (including nonlinearity and hysteresis) .against factory :t %RH :t2 %RH (0 ., 90 %RH) :t3 %RH (90 .100%RH) references .against field references 3 Temperature dependence Typical long-term stability Response time (at 20 °C, 90 % response) Settling time Sensor Temperature sensor Supply voltage Current consumption Operating temperature Protection class Weight Accessories :to.04 %RH/oC better than 1 % RH per year 15 s with membrane filter 1 s HUMICAP@ H-sensor (part no. 0062) Pt 100 (1/3 DIN 43760B, four-wire connection) 7...35VDC $:4 mA -40 ...+60 °C IP 55 (NEMA 3S) IP 65 (NEMA 4) * 180g radiation shield HMP 35A Sensor protection .standard .optional Housing material Cable length membrane filter (part no. 2787) plastic grid (part no. 6597) sintered filter 37 ~m (part no. 6685) sintered filter 216 ~m (part no. 6686) ASS plastic 1600 mm HMP 35D E.M.I. protection Sensor protection .standard IEC 801-3 standard, membrane filter, chromium-plated 2787) level 2 (part no. Sensor protection .optional sintered (part no. sintered (part no. Housing material chromium-plated plastic 3500 mm Cable length (* For details, Information filter 37 ~m 6685) fi1ter 216 ~m 6686) ASS consult your Vaisala representative. and specifications in this manual subject to change withough prior notice. Copyright Vaisala Oy, 1991. HUMICAP@ is a registered trademark of Vaisala. 5 HMP 35A Fig. 3 Fig. 3 Bild 3 Kuva 3 Electrical connections Connexions electriques Elektrische Anschlu~e Sahk6iset liitannat r Fig. 1 Fig. 1 Bild 1 Kuva 1 Dimensions, H M P 35A & H M P 35D Dimensions, H M P 35A & H M P 35D Mar5e, HMP 35A & HMP 35D Mitat, HMP 35A & HMP 35D Cable length Longueur du cable Lange des Kabels Kaapelin pituus HMP 35A 1600 mm HMP 350 3500 mm ,~ HMP 35D Fig. 4 Fig. 4 Bild 4 Kuva 4 Electrical connections Connexions electriques Elektrische AnschlOBe Sahk6iset liitannat -(, "'-'~~~"~""~.' - SHIELC
advertisement
Related manuals
advertisement