Setting of S90-ML…B01
Position the sensor and reflector aligned on opposite sides.
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power
on and off points of the yellow LED (OUT) and then mount the sensor in
the middle of the points defined.
Reduce sensitivity if very small objects have to be detected. Repeat
procedure reducing progressively the sensitivity in orde to improve
aligngment.
S90-ML SERIES
M4; 4mm deep
15
41.4
INSTRUCTION MANUAL
CONTROLS
8.8
OUTPUT LED (S90-ML…B01/C01/F01)
The yellow LED on indicates that the N.O.(normally open) output status
is closed.
POWER ON LED (S90-ML…B01/C01/F01/G00)
The green LED indicates that the sensor is operating and the laser is
active.
16.8
OUTPUT LED (S90-PL...B01/C01/F01)
POWER ON LED (S90-PL...G00)
TRIMMER
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S90-ML…B01/C01/F01
N.C. OUTPUT
(WHITE)
0 V-
2
1
3
4
1
3
4
(WHITE)
(BLUE)
Setting:
Operating mode:
Operating temperature:
Storage temperature:
Electrical protection:
Operating distance (typical values):
(BROWN)
N.O. OUTPUT
(BLACK)
TEST + 2
0 V-
Power supply:
Ripple:
Consumption
(output current excluded):
Outputs:
Ouput current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
+ 10 … 30 Vdc
S90-ML…G00
+ 10 … 30 Vdc
(BROWN)
NOT USED
(BLACK)
14.65
mm
TECHNICAL DATA
Emission type:
(BLUE)
M12
POWER ON LED (S90-PL...B01/C01/F01)
TRIMMER (S90-ML …B01/C01/F01)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
The sensor can be positioned by means of the housing’s holes using
two screws (M4x25 or longer, 1.5 Nm maximum tightening torque) with
washers.
Various orientable fixing brackets to ease the sensor positioning are
available (please refer to the accessories listed in the general
catalogue).
The
operating
distance
is
measured from the front surface
of the sensor optics.
The M12 connector can be
oriented at four different positions
rotating the block of 0°, 90°, 180°
or 270°.
16.9
5.1
26.7
50
16.9
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
Setting of S90-ML…F01/G00
Position the sensors aligned on opposite sides.
Turn the sensitivity trimmer to maximum: moving the sensor both
vertically and horizontally, determine the power on and off points of the
yellow LED (OUT) and then mount the sensor in the middle of the points
defined so that the yellow LED remains off.
If necessary, reduce sensitivity using the trimmer, in order to detect very
small targets. In order to improve alignment, repeat the procedure
detailed above whilst progressively reducing the sensitivity.
Setting of S90-ML…C01
Adjust the sentivity trimmer to minimum: the yellow
A
C
LED is off.
B
Position the target to detect in front of the sensor.
MAX
Turn the sensitivity trimmer clockwise until the yellow MIN
LED turns ON (Target detected state, pos.A).
Remove the target, the yellow LED turns OFF.
Turn the sensitivity trimmer clockwise until the yellow LED turns ON
(Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected.
Turn the trimmer to the intermediate position C, between the two
positions A and B.
TEST FUNCTION (S90-ML…G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and
verify that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted.
The inputs activating voltage range is 10 … 30 Vdc, with respect to 0 V
input (blue wire pin 3).
Connect the TEST+ input to 0 V if not used.
10 … 30 Vdc limit values
2 Vpp max.
35 mA max.
N.O. and N.C.; PNP or NPN; 30 Vdc max. (short-circuit protection) (mod. B01/C01/F01)
100 mA max.
2V
250 s (mod. B01/C01); 333 s (F01)
2 kHz (mod. B01/C01); 1.5 kHz (F01)
OUTPUT LED (YELLOW) (mod. B01/C01/F01)
POWER ON LED (GREEN) (mod. B01/C01/F01/G00)
senstivity trimmer (mod. B01/C01/F01)
LIGHT mode on N.O. output / DARK mode on N.C. output (mod.C01)
DARK mode on N.O. output / LIGHT mode on N.C. output (mod.B01/F01)
-10 … 50 °C
-25 … 70 °C
Class 2, double insulation
B01: 0.1…20 m on R2
C01: 0…60 cm
F01/G00: 0…60 m
RED LASER: Class 1 EN 60825-1 (1994) (mod.B01/C01/G00)
Class II CDRH 21 CFR PART 1040.10 (mod.B01/C01/G00)
Max. power  1 mW; Pulse = 4.2 S (mod.B01/C01); 5 S (mod.G00);
 = 630…680 nm; Frequency =33.5 kHz (mod.B01/C01); 10 kHz (mod.G00)
according to EN 60947-5-2
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
ZAMA
window in PMMA, lenses in glass and polycarbonate
IP67 (TYPE 1 ENCLOSURE)
M12 4-pole connector
77 g.
DECLARATION OF CONFORMITY
We DATALOGIC AUTOMATION declare under our sole responsibility
that these products are conform to the 2004/108/CE and successive
amendments.
WARRANTY
DATALOGIC AUTOMATION warrants its products to be free from
defects.
DATALOGIC AUTOMATION will repair or replace, free of charge, any
product found to be defective during the warranty period of 36 months
from the manufacturing date.
This warranty does not cover damage or liability deriving from the
improper application of DATALOGIC AUTOMATION products.
DATALOGIC AUTOMATION
Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
Tel: +39 051 6765611 - Fax: +39 051 6759324
www.automation.datalogic.com e-mail:info.automation.it@datalogic.com
DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and
improvements without prior notification.
Datalogic and the Datalogic logo are registered trademarks of Datalogic
S.p.A. in many countries, including the U.S.A. and the E.U.
826002061 Rev.C
© Copyright Datalogic 2003-2009