Delta | 16 SM600 | User manual | SM6000 - Se ries - Equipements Scientifiques
Add to my manuals6 Pages
The Delta 16 SM600 6000W DC power supply offers precise voltage and current control with a wide range of features for demanding applications. Its three-phase input and high power capabilities make it suitable for industrial and laboratory settings. With master/slave parallel and series operation, it provides flexible system configurations for increased power or redundancy. The SM600 ensures excellent dynamic response to load changes and protects against overload and short circuit conditions, ensuring reliable operation.
advertisement
▼
Scroll to page 2
of 6
DELTA ELEKTRONIKA B.V. SM 6000 - Series 6000 W DC POWER SUPPLIES Three phase input Models Voltage range Current range SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 0 - 15 V 0 - 30 V 0 - 45 V 0 - 60 V 0 - 70 V 0 - 120 V 0 - 300 V 0 - 600 V 0 - 400 A 0 - 200 A 0 - 140 A 0 - 100 A 0 - 90 A 0 - 50 A 0 - 20 A 0 - 10 A Features • • • • cTUVus safety approval • EMC surpasses CE requirements: low emission & high immunity • • Low audible noise: temperature controlled fans Functionalities • Master/Slave parallel and series operation with voltage and current sharing Excellent dynamic response to load changes • Protected against all overload and short circuit conditions Stacking is allowed, space between units is not required • High power system configuration from multiple units • 19" rack mounting or laboratory use (feet included) • Remote sensing • Interlock Designed for long life at full power Available options: analog & digital Interfaces, High Speed Programming, Digital Encoders, Sequencer, Power Sink etc. (ES) Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com DELTA ELEKTRONIKA BV SM6000 SM 15-400 SM 30-200 SM 45-140 SM 60-100 Output voltage current Input AC 3 phase, 48 - 62 Hz for use at 380 V, 400 V, 415 V nominal line - line voltage 0 - 15 V 0 - 400 A 0 - 30 V 0 - 200 A 0 - 45 V 0 - 140 A 0 - 60 V 0 - 100 A SM 70-90 0 - 70 V 0 - 90 A SM 120-50 SM 300-20 SM600-10 0 - 120 V 0 - 50 A 0 - 300 V 0 - 20 A 0-600 V 0-10 A 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V Option P165 for use at 440 V, 480 V (USA) (operates from 360 V, but at derated output, 5300 W@360 V) 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 10.2 A 10 A 10.3 A 0.98, 0.97 0.98, 0.97 0.98, 0.97 current (400 V / 3 ph, full load) power factor, 100%, 50% load 10 A 10.4 A 9.9 A 10 A 10 A 0.98, 0.97 0.98, 0.97 0.98, 0.97 0.98, 0.97 0.98, 0.97 15 AT 55 W 110 W 15 AT 55 W 110 W 15 AT 55 W 110 W 15 AT 55 W 110 W 15 AT 55 W 130 W 15 AT 55 W 130 W 15 AT 55 W 120 W 15 AT 55 W 130 W 87 % 89 % 90 % 89 % 89 % 89 % 89 % 89 % CV CV 2.5 mV 0.2 mV 5 mV 0.5 mV 5 mV 1 mV 5 mV 2 mV 5 mV 2 mV 8 mV 2 mV 15 mV 3 mV 20 mV 4 mV CC CC 24 mA 4 mA 12 mA 2 mA 9 mA 1.5 mA 6 mA 1 mA 5 mA 1 mA 3 mA 0.5 mA 1.2 mA 0.2 mA 1.0 mA 0.2 mA CV CV 0.8 mV 8 mV 1 mV 8 mV 1.5 mV 10 mV 2 mV 10 mV 2 mV 10 mV rms (BW=300 kHz) CC p-p (BW=20 MHz) CC CC-ripple at full load Temp. coeff., per °C CV CC Stability after 1 hr warm-up during 8 hrs CV CC tamb = 25 ± 1 °C, Vin = 400 V AC internal voltage sensing for CC-stab. 100 mA 300 mA 20 mA 60 mA 8 mA 25 mA 3 mA 10 mA 3 mA 10 mA 3 mV 25 mV (20 mV @ full load) 3 mA 10 mA 5 mV 50 mV (30 mV @ full load) 2 mA 5 mA 10 mV 100 mV (80 mV @ full load) 2 mA 5 mA internal fuses standby input power (Vo=Io=0) standby input power (Vo=Vmax) Efficiency 400 V AC, 3 ph input, full load Regulation Load 0 - 100% Line 342 - 457 V AC (external voltage sense) Load 0 - 100% Line 342 - 457 V AC (internal voltage sense, after warm-up) Ripple + noise rms (BW=300 kHz) p-p (BW=20 MHz) Analog Programming Note: for SM300-20 / SM600-10 see ISO AMP Programming inputs input range accuracy offset temp. coeff. offset input impedance Monitoring outputs output range accuracy offset temp. coeff. offset output impedance ISO AMP Programming optional for low volt. units up to120V (P154), standard on SM300-20 and SM600-10. Reference voltage on prog. connector +12 V output on prog. Connector Page 1 - 2 Page 1 -(ES) 2 Vref TC Vo Imax Ro 35.10-6 60.10-6 5.10-5 10.10-5 CV CC 0-5V ± 0.2% - 0.1 ... +1.3 mV (on 5V) 10 µV / °C > 1 MOhm 0-5V ± 0.5% 0 ... +2.2 mV (on 5V) 50 µV / °C > 1 MOhm 0-5V 0-5V ± 0.2% ± 0.5% - 1... 0 mV (on 5V) - 1.1 ... 0 mV (on 5V) 3 µV / °C 60 µV / °C 2 Ohm / max. 4 mA 2 Ohm / max. 4 mA Isolated analog programming, range 0 - 5 V / 200 kOhm or 0 - 10 V / 400 kOhm. See datasheet ISO AMP on www.DeltaPowerSupplies.com for accuracy, offset etc. 5.114 ± 15 mV (Ro = 2 Ohm, max. 4 mA) 20 ppm / °C 12 V ± 0.2 V 0.2 A 3 Ohm SPECIFICATIONS Rev. Sept. 2012 SPECIFICATIONS Rev. Sept. 2012 Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com SM6000 DELTA ELEKTRONIKA BV Status outputs CC - status LIM - status OT - status PSOL - status ACF - status DCF - status CC - operation CV or CC limit Over Temperature Power Sink Overload AC - Fail DC - Fail 1) Relay Outputs ACF DCF AC - Fail DC - Fail 1 ) 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 5 V = logic 1 both NO and NC contact both NO and NC contact 1 ) output ± 5% beyond set point with + 5V, 1 mA or relay contact Remote ShutDown contact at rear panel, see photo of rear panel on page 1-6 Interlock AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote-ShutDown, Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV- and CC- mode Indicators (front panel) Controls (Ro = 500 Ohm) (Ro = 500 Ohm) (Ro = 500 Ohm) (Ro = 500 Ohm) (Ro = 500 Ohm) (Ro = 500 Ohm) (front panel) Programming speed Standard Version (resistive load) Mains on/off, CV-and CC-potmeter, CV- and CC-limit-potmeter, Display-Settings button, Display-Limits button, Remote/Local, Output On/Off, Front panel Lock SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 Rise time (10 - 90%) output voltage step time, (100 % load) time, (10 % load) 0 → 15 V 3.3 ms 1.3 ms 0 → 30 V 6.4 ms 2.5 ms 0 → 45 V 2.7 ms 1.1 ms 0 → 60 V 5.4 ms 2.2 ms 0 → 70 V 6.8 ms 2.8 ms 0 → 120 V 0 → 300 V 0 → 600 V 5.1 ms 8.5 ms 12 ms 1.9 ms 3.2 ms 4.8 ms Fall time (90 - 10%) output voltage step time, (100 % load) time, (10 % load) 15 → 0 V 3.5 ms 34 ms 30 → 0 V 6.7 ms 67 ms 45 → 0 V 2.9 ms 32 ms 60 → 0 V 5.8 ms 59 ms 70 → 0 V 7.7 ms 77 ms 120 → 0 V 300 → 0 V 4.9 ms 8.3 ms 52 ms 83 ms Programming speed High Speed Version (resistive load) 600 → 0 V 12 ms 120 ms SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 Option P166 Option P167 Option P168 Option P169 Option P170 Option P171 Option P172 Option P270 Rise time (10 - 90%) output voltage step time, (100 % load) time, (10 % load) 0 → 15 V 0.40 ms 0.38 ms 0 → 30 V 0.41 ms 0.38 ms 0 → 45 V 0.53 ms 0.16 ms 0 → 60 V 0.44 ms 0.41 ms 0 → 70 V 0.62 ms 0.40 ms 0 → 120 V 0 → 300 V 0 → 600 V 0.57 ms 1.1 ms 1.9 ms 0.19 ms 0.44 ms 0.80 ms Fall time (90 - 10%) output voltage step time, (100 % load) time, (10 % load) 15 → 0 V 0.39 ms 1.5 ms 30 → 0 V 0.41 ms 3.6 ms 45 → 0 V 0.26 ms 10 ms 60 → 0 V 0.57 ms 5.6 ms 70 → 0 V 0.50 ms 6.2 ms 120 → 0 V 300 → 0 V 0.38 ms 1.0 ms 4.2 ms 10 ms 600 → 0 V 2.2 ms 20 ms 6/20mV 28/80mV 34/80mV 34/90mV 38/100mV 30/120mV 48/150mV 35/220mV 1200 µF 800 µF 520 µF 330 µF 290 µF 73 µF 32 µF 19 µF Ripple @ full load typical (rms / pp) Output Capacitance (typical) SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10 Recovery time recovery within di/dt of load step output voltage time, @ 50 - 100% load step max. deviation 60 mV 5 A/µs 13 V 120 µs 320 mV 50 mV 2.5 A/µs 25 V 100 µs 260 mV 100 mV 1.8 A/µs 40 V 100 µs 380 mV 100 mV 1.3 A/µs 55 V 100 µs 250 mV 100 mV 1.7 A/µs 65 V 100 µs 280 mV 0.5 V 1 A/µs 110 V 100 µs 1V 1V 0.25 A/µs 280 V 100 µs 1.8 V 1V 0.125 A/µs 560 V 100 µs 1.8 V Output impedance CV, 0-1 kHz CV, 1-100 kHz < 0.5 mΩ < 2.3 mΩ < 1.2 mΩ < 5 mΩ < 1.7 mΩ < 10 mΩ < 1.5 mΩ < 12 mΩ < 1.8 mΩ < 12 mΩ < 11 mΩ < 90 mΩ < 34 mΩ < 330 mΩ < 70 mΩ < 700 mΩ Pulsating load max. tolerable AC component of load current f > 1 kHz f < 1 kHz 30 Arms 35 Arms 20 Arms 20 Arms 400 Apeak 200 Apeak 140 Apeak 100 Apeak 20 Arms 90 Apeak 10 Arms 50 Apeak 5 Arms 20 Apeak 2.5 Arms 10 Apeak Insulation input / output creepage / clearance input / case output / case 3750 Vrms (1 min.) 8 mm 2500 Vrms 600 V DC (1200 V DC for SM300-20 and SM600-10) cTUVus / EN 60950 / EN 61010 Safety Page 1 - 3 SPECIFICATIONS Rev. 2012 (ES)Sept. Equipements Rev. Sept. 2012 Page 1 - 3 Scientifiques SA - Département TestsSPECIFICATIONS Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com DELTA ELEKTRONIKA BV EMC SM6000 Power Supply Standard EN 61204-3, Emission: residential, light industrial environment (CISPR22-Class B) Immunity: industrial environment Generic Emission Generic Immunity EN 61000-6-3, residential, light industrial environment (EN 55022 B) EN 61000-6-2, industrial environment − 20 to + 50 °C derate output to 75% at 60 °C Operating Temperature at full load max. 95% RH, non condensing, up to 40 °C max. 75% RH, non condensing, up to 50 °C Humidity − 40 to + 85 °C Storage temperature Output shuts down in case of insufficient cooling Thermal protection 500 000 hrs MTBF SM 15-400 SM 30-200 SM 45-140 SM 60-100 Hold-Up time Vout = 100%, Iout = 100% Vout = 85%, Iout = 100% Vout = 100%, Iout = 50% @ 400 V AC input 11 ms 23 ms 33 ms 11 ms 23 ms 28 ms 11 ms 23 ms 27 ms 11 ms 24 ms 28 ms Turn on delay after mains switch on 13 ms 23 ms 30 ms SM 120-50 SM 300-20 SM 600-10 13 ms 24 ms 32 ms 1200 V yes 1200V yes Output shuts down in case of phase loss Series operation max. total voltage Master / Slave operation 600 V yes 600 V yes 600 V yes 600 V yes Parallel operation Normal Master / Slave operation 600 V yes Voltage Current 600 V yes no limit max. 3 units Remote sensing max. voltage drop per load lead 2V 0 - 102% 0 - 102% adjust range adjust range Front panel CV/CC-controls resolution knob operation screwdriver adjustment Lock function for CV/CC-settings Selectable Start-up at 0V / 0A or at last settings analog potentiometers1) 10 turns (0.03%) standard optional (P001) digital encoders 10 or 64 turns2) standard no no no yes yes 1) 2) optional with digital encoders (P220) : specifications for controls are similar to SM300-20 and SM600-10. Meters scale voltage scale current accuracy read output read limit setting (d = digit) variable pitch depending on operation speed 3.5 digit 3.5 digit 3.5 digit 3.5 digit 3.5 digit 3.5 digit 3.5 digit 3.5 digit 0 - 15.00 V 0 - 30.0 V 0 - 45.0 V 0 - 60.0 V 0 - 70.0 V 0 - 120.0 V 0 - 300 V 0 - 600 V 0 - 400 A 0 - 200 A 0 - 140.0 A 0 - 100.0 A 0 - 90.0 A 0 - 50.0 A 0 - 20.0 A 0 - 10.0 A 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 2% + 2 d 2% + 2 d 2% + 2 d 2% + 2 d 2% + 2 d 2% + 2 d 2% + 2 d 2% + 2 d Stacking of units allowed, air flow is from left to right. Mounting Screw Terminals for cable 2.5 - 4 mm2, 3 phase + earth (no neutral required) Input Terminals Output Terminals Programming connector Cooling audio noise level airflow M12 bolts M10 bolts M10 bolts M10 bolts Dimensions behind front panel: h x w x d front panel: h x w M10 bolts M8 bolts M8 bolts M8 bolts 15 pole D-connector at rear panel (FEMALE) Low noise blower, fan speed adapts to temperature of internal heatsink. ca. 56 dBA at full load, 25 °C ambient temperature, 1 m distance ca. 62 dBA at full load, 50 °C ambient temperature, 1 m distance From left to right Enclosure degree of protection IP20 177 x 443 x 500 mm 177 x 483 mm (19", 4 U) 27 kg Weight Page 1 -(ES) 4 11 ms 23 ms 27 ms 200 ms Phase loss Page 1 - 4 12 ms 24 ms 28 ms 20 A (electronic limit) Inrush current Limits SM 70-90 SPECIFICATIONS Rev. Sept. 2012 SPECIFICATIONS Rev. Sept. 2012 Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com SM6000 DELTA ELEKTRONIKA BV Typical Applications • • • • • • • Solar inverter testing, PV-Simulation Controlled Battery (dis)charging Plasma chambers Lasers Hybrid Car test systems Driving PWM-Controlled DC motors • • • Accurate current sources Automotive battery simulations Aerospace and military equipment ATE in industrial production lines Available Options High Speed Programming Increased Output Power Two-Quadrant Output: Power sink The conservatively rated unit allows to deliver extra output with the same reliability. At some derating, either the maximum output voltage or the maximum output current can be increased by about 10%. A 10 to 20 times higher programming speed (down to 0.4 ms rise time at full load) and lower output capacitance 1). Excellent for laser applications, test systems or as current source with low parallel capacitance as used in plasma chambers. Two quadrant operations maintains the output voltage constant regardless the output power is positive or negative 1). Ideal for PWM-speed controlled DC-motors and ATE systems. • Order Code - P069 • Order Codes: SM 15-400 P166 SM 45-140 P168 SM 70-90 P170 SM 300-20 P172 • Order Codes: SM 15-400 P230 SM 45-140 P232 SM 70-90 P234 SM 30-200 P167 SM 60-100 P169 SM 120-50 P171 SM 600-10 P270 - SM 30-200 P231 SM 60-100 P233 Sequencer High Voltage Isolation High Input Voltage Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. A higher output isolation allows series operation up to 1200V. Is standard on SM300-20 and SM600-10. Higher input voltages possible for operations at line voltages of 440 V AC and 480 V AC (for USA). • Order Code - P157 • Order Code - P089 Software control and Interfaces Digital Voltage and Current Setting Factory installed programming interfaces 2): • • • • • • - ISO AMP Card - isolated analog RS232 controller IEEE488 controller Ethernet contr. (incl. sequencer) PROFIBUS controller CANBUS controller - P154 3) P155 P156 P157 P277 P278 Reliable, longlife digital encoders can be implemented at the front panel. Includes total front panel lock (also for CV/CC-knobs) and a coarse or fine pitch adjustment depending on the turning speed. Is standard on SM300-20 and SM600-10. • Order Code - P165 Secured Voltage and Current Setting For a maximum security, the CV/CC settings can be adjusted with a screwdriver only and are protected with a plastic cap from accidental adjusting. SM300-20, SM600-10 and units with option P220 already have secured settings. • Order Code - P220 • Order Code - P001 Notes: 1. Download special datasheets about High Speed Progr., Power Sink and Battery Charging from www.DeltaPowerSupplies.com. 2. There is only room for one of the interfaces in a unit (P154, P155, P156, P157, P277 or P278). 3. SM300-20 and SM 600-10 standard equipped with ISO AMP, this can be replaced by P155, P156, P157, P277 or P278. Page 1 - 5 SPECIFICATIONS Rev. Sept. 2012 Rev. 2012 (ES)Sept. Equipements Page 1 - 5 Scientifiques SA - Département TestsSPECIFICATIONS Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com DELTA ELEKTRONIKA BV SM6000 CV= Constant Voltage CC= Constant Current Specifications measured at tamb = 25 ± 5 °C and Vin = 400 V AC, 50 Hz, 3 phase, unless otherwise noted. The information in this document is subject to change without notice Connections analog programming connector InterLock Master/ Slave Status Relay Programming Connectors analog (standard) RS232, CANopen, PROFIBUS, Ethernet user I/O (all optional) Sense Block Ethernet, IEEE488, isolated analog (all optional) Output Terminals NO Line Cord supplied Input Connector Safety Covers supplied for in- and output (not shown) Feet are not mounted but included in packing Note: SM300-20 and SM 600-10 standard with isolated analog programming via ISO AMP on CON H (CON E is not available). Page 1 - 6 SPECIFICATIONS Rev. Sept. 2012 (ES) Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project