DELTA ELEKTRONIKA B.V.
SM 6000 - Series
6000 W DC POWER SUPPLIES
Three phase input
Models
Voltage range
Current range
SM 15-400
SM 30-200
SM 45-140
SM 60-100
SM 70-90
SM 120-50
SM 300-20
SM 600-10
0 - 15 V
0 - 30 V
0 - 45 V
0 - 60 V
0 - 70 V
0 - 120 V
0 - 300 V
0 - 600 V
0 - 400 A
0 - 200 A
0 - 140 A
0 - 100 A
0 - 90 A
0 - 50 A
0 - 20 A
0 - 10 A
Features
•
•
•
•
cTUVus safety approval
•
EMC surpasses CE requirements:
low emission & high immunity
•
•
Low audible noise: temperature controlled fans
Functionalities
•
Master/Slave parallel and series operation with
voltage and current sharing
Excellent dynamic response to load changes
•
Protected against all overload and short circuit
conditions
Stacking is allowed, space between units
is not required
•
High power system configuration from multiple units
•
19" rack mounting or laboratory use
(feet included)
•
Remote sensing
•
Interlock
Designed for long life at full power
Available options: analog & digital Interfaces,
High Speed Programming, Digital Encoders,
Sequencer, Power Sink etc.
(ES) Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
DELTA ELEKTRONIKA BV
SM6000
SM 15-400 SM 30-200 SM 45-140 SM 60-100
Output
voltage
current
Input
AC 3 phase, 48 - 62 Hz
for use at 380 V, 400 V, 415 V
nominal line - line voltage
0 - 15 V
0 - 400 A
0 - 30 V
0 - 200 A
0 - 45 V
0 - 140 A
0 - 60 V
0 - 100 A
SM 70-90
0 - 70 V
0 - 90 A
SM 120-50 SM 300-20 SM600-10
0 - 120 V
0 - 50 A
0 - 300 V
0 - 20 A
0-600 V
0-10 A
342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V
Option P165
for use at 440 V, 480 V (USA)
(operates from 360 V, but at
derated output, 5300 W@360 V)
396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V 396 - 519 V
10.2 A
10 A
10.3 A
0.98, 0.97 0.98, 0.97 0.98, 0.97
current (400 V / 3 ph, full load)
power factor, 100%, 50% load
10 A
10.4 A
9.9 A
10 A
10 A
0.98, 0.97 0.98, 0.97 0.98, 0.97 0.98, 0.97 0.98, 0.97
15 AT
55 W
110 W
15 AT
55 W
110 W
15 AT
55 W
110 W
15 AT
55 W
110 W
15 AT
55 W
130 W
15 AT
55 W
130 W
15 AT
55 W
120 W
15 AT
55 W
130 W
87 %
89 %
90 %
89 %
89 %
89 %
89 %
89 %
CV
CV
2.5 mV
0.2 mV
5 mV
0.5 mV
5 mV
1 mV
5 mV
2 mV
5 mV
2 mV
8 mV
2 mV
15 mV
3 mV
20 mV
4 mV
CC
CC
24 mA
4 mA
12 mA
2 mA
9 mA
1.5 mA
6 mA
1 mA
5 mA
1 mA
3 mA
0.5 mA
1.2 mA
0.2 mA
1.0 mA
0.2 mA
CV
CV
0.8 mV
8 mV
1 mV
8 mV
1.5 mV
10 mV
2 mV
10 mV
2 mV
10 mV
rms
(BW=300 kHz) CC
p-p
(BW=20 MHz) CC
CC-ripple at full load
Temp. coeff., per °C
CV
CC
Stability
after 1 hr warm-up
during 8 hrs
CV
CC
tamb = 25 ± 1 °C, Vin = 400 V AC
internal voltage sensing for
CC-stab.
100 mA
300 mA
20 mA
60 mA
8 mA
25 mA
3 mA
10 mA
3 mA
10 mA
3 mV
25 mV
(20 mV @
full load)
3 mA
10 mA
5 mV
50 mV
(30 mV @
full load)
2 mA
5 mA
10 mV
100 mV
(80 mV @
full load)
2 mA
5 mA
internal fuses
standby input power (Vo=Io=0)
standby input power (Vo=Vmax)
Efficiency
400 V AC, 3 ph input, full load
Regulation
Load 0 - 100%
Line 342 - 457 V AC
(external voltage sense)
Load 0 - 100%
Line 342 - 457 V AC
(internal voltage sense,
after warm-up)
Ripple + noise
rms
(BW=300 kHz)
p-p
(BW=20 MHz)
Analog Programming
Note: for SM300-20 / SM600-10 see ISO AMP
Programming inputs
input range
accuracy
offset
temp. coeff. offset
input impedance
Monitoring outputs
output range
accuracy
offset
temp. coeff. offset
output impedance
ISO AMP Programming
optional for low volt. units up to120V (P154),
standard on SM300-20 and SM600-10.
Reference voltage
on prog. connector
+12 V output
on prog. Connector
Page 1 - 2
Page 1 -(ES)
2
Vref
TC
Vo
Imax
Ro
35.10-6
60.10-6
5.10-5
10.10-5
CV
CC
0-5V
± 0.2%
- 0.1 ... +1.3 mV (on 5V)
10 µV / °C
> 1 MOhm
0-5V
± 0.5%
0 ... +2.2 mV (on 5V)
50 µV / °C
> 1 MOhm
0-5V
0-5V
± 0.2%
± 0.5%
- 1... 0 mV (on 5V)
- 1.1 ... 0 mV (on 5V)
3 µV / °C
60 µV / °C
2 Ohm / max. 4 mA
2 Ohm / max. 4 mA
Isolated analog programming, range 0 - 5 V / 200 kOhm or 0 - 10 V / 400 kOhm.
See datasheet ISO AMP on www.DeltaPowerSupplies.com for accuracy, offset etc.
5.114 ± 15 mV (Ro = 2 Ohm, max. 4 mA)
20 ppm / °C
12 V ± 0.2 V
0.2 A
3 Ohm
SPECIFICATIONS
Rev. Sept. 2012
SPECIFICATIONS
Rev. Sept.
2012
Equipements Scientifiques SA - Département
Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380
Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
SM6000
DELTA ELEKTRONIKA BV
Status outputs
CC
- status
LIM
- status
OT
- status
PSOL
- status
ACF
- status
DCF
- status
CC - operation
CV or CC limit
Over Temperature
Power Sink Overload
AC - Fail
DC - Fail 1)
Relay Outputs
ACF
DCF
AC - Fail
DC - Fail
1
)
5 V = logic 1
5 V = logic 1
5 V = logic 1
5 V = logic 1
5 V = logic 1
5 V = logic 1
both NO and NC contact
both NO and NC contact
1
) output ± 5% beyond set point
with + 5V, 1 mA or relay contact
Remote ShutDown
contact at rear panel, see photo of rear panel on page 1-6
Interlock
AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote-ShutDown,
Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV- and CC- mode
Indicators (front panel)
Controls
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(Ro = 500 Ohm)
(front panel)
Programming speed
Standard Version
(resistive load)
Mains on/off, CV-and CC-potmeter, CV- and CC-limit-potmeter, Display-Settings button, Display-Limits button, Remote/Local, Output On/Off, Front panel Lock
SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10
Rise time (10 - 90%)
output voltage step
time, (100 % load)
time, (10 % load)
0 → 15 V
3.3 ms
1.3 ms
0 → 30 V
6.4 ms
2.5 ms
0 → 45 V
2.7 ms
1.1 ms
0 → 60 V
5.4 ms
2.2 ms
0 → 70 V
6.8 ms
2.8 ms
0 → 120 V 0 → 300 V 0 → 600 V
5.1 ms
8.5 ms
12 ms
1.9 ms
3.2 ms
4.8 ms
Fall time (90 - 10%)
output voltage step
time, (100 % load)
time, (10 % load)
15 → 0 V
3.5 ms
34 ms
30 → 0 V
6.7 ms
67 ms
45 → 0 V
2.9 ms
32 ms
60 → 0 V
5.8 ms
59 ms
70 → 0 V
7.7 ms
77 ms
120 → 0 V 300 → 0 V
4.9 ms
8.3 ms
52 ms
83 ms
Programming speed
High Speed Version
(resistive load)
600 → 0 V
12 ms
120 ms
SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10
Option P166 Option P167 Option P168 Option P169 Option P170 Option P171 Option P172 Option P270
Rise time (10 - 90%)
output voltage step
time, (100 % load)
time, (10 % load)
0 → 15 V
0.40 ms
0.38 ms
0 → 30 V
0.41 ms
0.38 ms
0 → 45 V
0.53 ms
0.16 ms
0 → 60 V
0.44 ms
0.41 ms
0 → 70 V
0.62 ms
0.40 ms
0 → 120 V 0 → 300 V 0 → 600 V
0.57 ms
1.1 ms
1.9 ms
0.19 ms
0.44 ms
0.80 ms
Fall time (90 - 10%)
output voltage step
time, (100 % load)
time, (10 % load)
15 → 0 V
0.39 ms
1.5 ms
30 → 0 V
0.41 ms
3.6 ms
45 → 0 V
0.26 ms
10 ms
60 → 0 V
0.57 ms
5.6 ms
70 → 0 V
0.50 ms
6.2 ms
120 → 0 V 300 → 0 V
0.38 ms
1.0 ms
4.2 ms
10 ms
600 → 0 V
2.2 ms
20 ms
6/20mV
28/80mV
34/80mV
34/90mV
38/100mV
30/120mV
48/150mV
35/220mV
1200 µF
800 µF
520 µF
330 µF
290 µF
73 µF
32 µF
19 µF
Ripple
@ full load
typical (rms / pp)
Output Capacitance (typical)
SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10
Recovery time
recovery within
di/dt of load step
output voltage
time, @ 50 - 100% load step
max. deviation
60 mV
5 A/µs
13 V
120 µs
320 mV
50 mV
2.5 A/µs
25 V
100 µs
260 mV
100 mV
1.8 A/µs
40 V
100 µs
380 mV
100 mV
1.3 A/µs
55 V
100 µs
250 mV
100 mV
1.7 A/µs
65 V
100 µs
280 mV
0.5 V
1 A/µs
110 V
100 µs
1V
1V
0.25 A/µs
280 V
100 µs
1.8 V
1V
0.125 A/µs
560 V
100 µs
1.8 V
Output impedance
CV, 0-1 kHz
CV, 1-100 kHz
< 0.5 mΩ
< 2.3 mΩ
< 1.2 mΩ
< 5 mΩ
< 1.7 mΩ
< 10 mΩ
< 1.5 mΩ
< 12 mΩ
< 1.8 mΩ
< 12 mΩ
< 11 mΩ
< 90 mΩ
< 34 mΩ
< 330 mΩ
< 70 mΩ
< 700 mΩ
Pulsating load
max. tolerable AC component
of load current
f > 1 kHz
f < 1 kHz
30 Arms
35 Arms
20 Arms
20 Arms
400 Apeak 200 Apeak 140 Apeak 100 Apeak
20 Arms
90 Apeak
10 Arms
50 Apeak
5 Arms
20 Apeak
2.5 Arms
10 Apeak
Insulation
input / output
creepage / clearance
input / case
output / case
3750 Vrms (1 min.)
8 mm
2500 Vrms
600 V DC (1200 V DC for SM300-20 and SM600-10)
cTUVus / EN 60950 / EN 61010
Safety
Page 1 - 3
SPECIFICATIONS
Rev.
2012
(ES)Sept.
Equipements
Rev. Sept. 2012
Page 1 - 3
Scientifiques SA - Département TestsSPECIFICATIONS
Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
DELTA ELEKTRONIKA BV
EMC
SM6000
Power Supply Standard
EN 61204-3,
Emission: residential, light industrial environment (CISPR22-Class B)
Immunity: industrial environment
Generic Emission
Generic Immunity
EN 61000-6-3, residential, light industrial environment (EN 55022 B)
EN 61000-6-2, industrial environment
− 20 to + 50 °C
derate output to 75% at 60 °C
Operating Temperature at full load
max. 95% RH, non condensing, up to 40 °C
max. 75% RH, non condensing, up to 50 °C
Humidity
− 40 to + 85 °C
Storage temperature
Output shuts down in case of insufficient cooling
Thermal protection
500 000 hrs
MTBF
SM 15-400 SM 30-200 SM 45-140 SM 60-100
Hold-Up time
Vout = 100%,
Iout = 100%
Vout = 85%,
Iout = 100%
Vout = 100%,
Iout = 50%
@ 400 V AC input
11 ms
23 ms
33 ms
11 ms
23 ms
28 ms
11 ms
23 ms
27 ms
11 ms
24 ms
28 ms
Turn on delay
after mains switch on
13 ms
23 ms
30 ms
SM 120-50 SM 300-20 SM 600-10
13 ms
24 ms
32 ms
1200 V
yes
1200V
yes
Output shuts down in case of phase loss
Series operation
max. total voltage
Master / Slave operation
600 V
yes
600 V
yes
600 V
yes
600 V
yes
Parallel operation
Normal
Master / Slave operation
600 V
yes
Voltage
Current
600 V
yes
no limit
max. 3 units
Remote sensing
max. voltage drop per load lead
2V
0 - 102%
0 - 102%
adjust range
adjust range
Front panel CV/CC-controls
resolution
knob operation
screwdriver adjustment
Lock function for CV/CC-settings
Selectable Start-up at 0V / 0A or
at last settings
analog potentiometers1)
10 turns (0.03%)
standard
optional (P001)
digital encoders
10 or 64 turns2)
standard
no
no
no
yes
yes
1)
2)
optional with digital encoders (P220) : specifications
for controls are similar to SM300-20 and SM600-10.
Meters
scale
voltage
scale
current
accuracy read output
read limit setting
(d = digit)
variable pitch depending on
operation speed
3.5 digit
3.5 digit
3.5 digit
3.5 digit
3.5 digit
3.5 digit
3.5 digit
3.5 digit
0 - 15.00 V 0 - 30.0 V 0 - 45.0 V 0 - 60.0 V 0 - 70.0 V 0 - 120.0 V 0 - 300 V
0 - 600 V
0 - 400 A
0 - 200 A 0 - 140.0 A 0 - 100.0 A 0 - 90.0 A 0 - 50.0 A 0 - 20.0 A 0 - 10.0 A
0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d 0.5% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
2% + 2 d
Stacking of units allowed, air flow is from left to right.
Mounting
Screw Terminals for cable 2.5 - 4 mm2, 3 phase + earth (no neutral required)
Input Terminals
Output Terminals
Programming connector
Cooling
audio noise level
airflow
M12 bolts
M10 bolts
M10 bolts
M10 bolts
Dimensions
behind front panel: h x w x d
front panel: h x w
M10 bolts
M8 bolts
M8 bolts
M8 bolts
15 pole D-connector at rear panel (FEMALE)
Low noise blower, fan speed adapts to temperature of internal heatsink.
ca. 56 dBA at full load, 25 °C ambient temperature, 1 m distance
ca. 62 dBA at full load, 50 °C ambient temperature, 1 m distance
From left to right
Enclosure
degree of protection
IP20
177 x 443 x 500 mm
177 x 483 mm (19", 4 U)
27 kg
Weight
Page 1 -(ES)
4
11 ms
23 ms
27 ms
200 ms
Phase loss
Page 1 - 4
12 ms
24 ms
28 ms
20 A (electronic limit)
Inrush current
Limits
SM 70-90
SPECIFICATIONS
Rev. Sept. 2012
SPECIFICATIONS
Rev. Sept.
2012
Equipements Scientifiques SA - Département
Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380
Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
SM6000
DELTA ELEKTRONIKA BV
Typical Applications
•
•
•
•
•
•
•
Solar inverter testing,
PV-Simulation
Controlled Battery (dis)charging
Plasma chambers
Lasers
Hybrid Car test systems
Driving PWM-Controlled DC motors
•
•
•
Accurate current sources
Automotive battery simulations
Aerospace and military equipment
ATE in industrial production lines
Available Options
High Speed
Programming
Increased Output
Power
Two-Quadrant
Output: Power sink
The conservatively rated unit
allows to deliver extra output
with the same reliability.
At some derating, either the maximum output
voltage or the maximum output current can be
increased by about 10%.
A 10 to 20 times higher
programming speed (down to
0.4 ms rise time at full load)
and lower output capacitance 1). Excellent for
laser applications, test systems or as current
source with low parallel capacitance as used
in plasma chambers.
Two quadrant operations
maintains the output
voltage constant
regardless the output power is positive or
negative 1). Ideal for PWM-speed
controlled DC-motors and ATE systems.
• Order Code - P069
• Order Codes:
SM 15-400 P166
SM 45-140 P168
SM 70-90 P170
SM 300-20 P172
• Order Codes:
SM 15-400 P230
SM 45-140 P232
SM 70-90 P234
SM 30-200 P167
SM 60-100 P169
SM 120-50 P171
SM 600-10 P270
-
SM 30-200 P231
SM 60-100 P233
Sequencer
High Voltage Isolation
High Input Voltage
Arbitrary Waveform generator
or standalone automation.
The sequencer is integrated
in the Ethernet controller.
A higher output isolation
allows series operation
up to 1200V. Is standard on
SM300-20 and SM600-10.
Higher input voltages
possible for operations at
line voltages of 440 V AC
and 480 V AC (for USA).
• Order Code - P157
• Order Code - P089
Software control
and Interfaces
Digital Voltage and
Current Setting
Factory installed programming
interfaces 2):
•
•
•
•
•
•
-
ISO AMP Card - isolated analog
RS232 controller
IEEE488 controller
Ethernet contr. (incl. sequencer)
PROFIBUS controller
CANBUS controller
-
P154 3)
P155
P156
P157
P277
P278
Reliable, longlife digital
encoders can be implemented at the front panel.
Includes total front panel lock (also for
CV/CC-knobs) and a coarse or fine pitch
adjustment depending on the turning speed.
Is standard on SM300-20 and SM600-10.
• Order Code - P165
Secured Voltage
and Current Setting
For a maximum security,
the CV/CC settings can
be adjusted with a
screwdriver only and are protected with a
plastic cap from accidental adjusting.
SM300-20, SM600-10 and units with
option P220 already have secured
settings.
• Order Code - P220
• Order Code - P001
Notes: 1. Download special datasheets about High Speed Progr., Power Sink and Battery Charging from www.DeltaPowerSupplies.com.
2. There is only room for one of the interfaces in a unit (P154, P155, P156, P157, P277 or P278).
3. SM300-20 and SM 600-10 standard equipped with ISO AMP, this can be replaced by P155, P156, P157, P277 or P278.
Page 1 - 5
SPECIFICATIONS
Rev. Sept. 2012
Rev.
2012
(ES)Sept.
Equipements
Page 1 - 5
Scientifiques SA - Département TestsSPECIFICATIONS
Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
DELTA ELEKTRONIKA BV
SM6000
CV= Constant Voltage
CC= Constant Current
Specifications measured at
tamb = 25 ± 5 °C and Vin = 400 V AC, 50
Hz, 3 phase, unless otherwise noted.
The information in this document is
subject to change without notice
Connections analog programming connector
InterLock
Master/
Slave
Status Relay
Programming Connectors
analog
(standard)
RS232, CANopen, PROFIBUS,
Ethernet user I/O (all optional)
Sense Block
Ethernet, IEEE488,
isolated analog (all optional)
Output Terminals
NO Line Cord
supplied
Input Connector
Safety Covers supplied for in- and output (not shown)
Feet are not mounted
but included in packing
Note: SM300-20 and SM 600-10 standard with isolated analog programming via ISO AMP on CON H (CON E is not available).
Page 1 - 6
SPECIFICATIONS
Rev. Sept. 2012
(ES) Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement