advertisement
Service Manual
No-Frost
Combi-Refrigerator
Models:
ERF-366N, 366A
ERF-396N, 396A
ERF-416N, 416A
DAEWOO ELECTRONICS
MANUFACTURING ESPAÑA, S.A.
Downloaded from Fridge-Manual.com Manuals
. CONTENTS
1. SPECIFICATIONS
2. EXTERNAL DRAWINGS
3. REAL VIEW
4. MACHINE ROOM VIEW
5. REFRIGERANT CYCLE
6. TEMPERATURES DIAGRAM
7. WIRING DIAGRAMS
8. PCB CIRCUIT DIAGRAMS
9. COMPONENTS DISASSEMBLY PICTURES
10. DOOR POSITION CHANGE PROCESS
11. EXPLODE DRAWING
12. PARTS LIST
13. PCB CONTROL FUNCTION
Downloaded from Fridge-Manual.com Manuals
1
1. SPECIFICATIONS
Model name
Division
Refrigerant type
Refrigerant Q´ty
Blowing agent
Cooling system
Defrost system
Compressor
Rated voltage
Rated input (A)
Lamp rated input (W)
Gross capacity
(liter)
Freezer
Refrigerator
Total
External dimension
(m m )
Height
Width
Depth *
Energy class
Freezing capacity(kg/24h)
Star rating
Climate class
Net weight (kg)
366N 366A 396N 396A 416N 416A
Semi A Full A Semi A Full A Semi A Full A
R-134A
100 grs
C-PENTANE
Fan cooling system
Automatic start & Automatic stop system
Sanyo CBE-140L5Z
AC220~240V / 50Hz
0.42A
15
94
218
312
1765
600
642
94
218
312
1765
600
642
94
252
346
1896
600
642
94
252
346
1896
600
642
109
252
361
1985
600
642
109
252
361
1985
600
642
A
5
* *** * *** * *** * *** * *** * ***
N N N N N N
70 70 74 74 76 76
REMARKS:
* Depth exception handle
* Division: Semi A = Semi automatic
Full A = Full automatic
1.2. Types of the approved safety standars
Downloaded from Fridge-Manual.com Manuals
2
2. EXTERNAL DRAWINGS
2.1. ERF-366A, 396A, 416A
1.
2.
3.
4.
5.
6.
Shelves ( ERF-366 A : 2EA )
( ERF-396 A : 3EA )
( ERF-416 A : 3EA )
Multi duct
Shelf of low temp compartment
Door of low temp compartment
Low temp compartment
Cover vegetable
7.
8.
Knob humidity
Vegetable case "L"
9.
Vegetable case "R"
10.
Case f "D"
11.
Case icing ( In "case f d" )
12.
Case f "B" ( 2EA)
Case f "C" ( ERF-416 A : 2EA)
13.
Case f "A"
14.
Cover dairy
15.
Dairy pocket
16.
Pocket "R"
17.
Bottle pocket
18.
Guide bottle pocket
19.
Multi pocket
20.
Adjustable foot
2.2. ERF-366N, 396N, 416N 1. Shelves ( ERF-366 N : 2EA )
( ERF-396 N : 3EA )
( ERF-416 N : 3EA )
2. Knob control
3. Multi duct
4. Shelf of low temp compartment
5. Low temp compartment
6. Door of low temp compartment
7. Cover vegetable
8. Knob humidity
9. Vegetable case "L"
10. Vegetable case "R"
11. Case f "D"
12. Case icing ( In "case f d" )
13. Case f "B" (2EA)
Case f "C" ( ERF-416 N : 2EA)
14. Case f "A"
15. Cover dairy
16. Dairy pocket
17. Pocket "R"
18. Bottle pocket
19. Guide bottle pocket
20. Multi pocket
21. Adjustable foot
Downloaded from Fridge-Manual.com Manuals
3
3. REAL VIEW
Downloaded from Fridge-Manual.com Manuals
4
4. MACHINE ROOM VIEW
Downloaded from Fridge-Manual.com Manuals
5
SCREW MACHINE
5. REFRIGERANT CYCLE
CAPILLARY TUBE
Downloaded from Fridge-Manual.com Manuals
6
6. TEMPERATURES DIAGRAM
Refrigerator
SUPER
HIGH
MID
LOW
VAC
: 0 ºC
: 1 ºC
: 3 ºC
: 5 ºC
: 6 ºC
Low temp compartment : 3 ºC
Vegetables compartment: 0 ºC~5 ºC
Freezer:
SUPER
HIGH
MID
LOW
VAC
: -23 ºC
: -22 ºC
: -20 ºC
: -18 ºC
: -16 ºC
Downloaded from Fridge-Manual.com Manuals
7
7. WIRING DIAGRAMS
7.1- ERF-XX6A
Downloaded from Fridge-Manual.com Manuals
8
7.2- ERF-XX6N
Downloaded from Fridge-Manual.com Manuals
9
8. PCB CIRCUIT DIAGRAMS
8.1- ERF-XX6A
Downloaded from Fridge-Manual.com Manuals
10
8.2- ERF-XX6N
Downloaded from Fridge-Manual.com Manuals
11
9. COMPONENTS DISASSEMBLY PICTURES
1- FRONT PCB (FULL AUTOMATIC TYPE)
- Input a cutter sleeve between
Window FCP and Panel F control.
Important: Input carefully cutter in the area that picture shows (down right).
- Lift Window FCP up.
* Remark: Input cutter deeply and carefully in order to lift up easily and avoid paint damages and scratches.
- Unscrew Panel F Control.
Downloaded from Fridge-Manual.com Manuals
12
- Unscrew the two fixing screws of
F-PCB as.
2- SWITCH DOOR
- Force switch door to the left side and input a thin driver in the rigth part as picture shows.
After this operation, lift switch up.
* Remark: Input driver carefully in order to lift up easily and avoid paint damages and scratches.
- move switch to left side.
- Take out switch and disconnect housing.
Downloaded from Fridge-Manual.com Manuals
13
3- M-PCB
- Unscrew the two fixing screws of cover PCB box.
- Disconnect all housings connectors from M-pcb, and force plastic locker of pcb box in order to take out the pcb.
* Remark: In ERF-xx6N models forced defrost button is located in M-PCB, so pcb box cover must be disassembled
4- RELAY BOX COVER
- Press relay box cover stopper sleeve with a minus driver like picture shows.
Downloaded from Fridge-Manual.com Manuals
14
5- MULTI DUCT
- Take out window r pulling the top part sleeve.
- Unscrew all fixing screws
- To disassemble V-PCB force left plastic stopper and lift pcb up.
- To disassemble R-sensor lift it up from the wires carefully.
Downloaded from Fridge-Manual.com Manuals
15
6- LOUVERS:
- Unscrew the two fixing screw for disassembly louver A and B
TO DIASEMBLE IT IS
NECESSARY A STAR
DRIVER WITH A
MINIMAL LENGHT OF
10 CM
- Disconnect fan motor housing
- Unscrew the fixing screw in order to disassemble Louver A.
Downloaded from Fridge-Manual.com Manuals
16
- When louvers are disassembled is very important check Knob F louver position.
Default position is M
L POSITION
L POSITION H POSITION
7-CHANGE DOOR OPEN SIDE
- Unscrew cover T hinge
- Before changing door open side, disconnect door housing connector.
Follow next sheets instructions to change door open side
Downloaded from Fridge-Manual.com Manuals
17
10. DOOR POSITION CHANGE PROCESS
STEP 1 : Remove door Follow to remove
1. Remove“ COV ER HINGE” and “
HINGE T”
2. Remove“ R” door.
3. Remove “ HINGE M”
4. Remove“ F” door
5. Remove“COV ER BRACKET”
6. Remove“ HINGE U”
STEP 2 : Change door handle
7. Reverse the position of“ COV ER
BU SHING”
8. Move “ R DOOR HANDLE” to “ F
DOOR”
9. Reverse the position of“ CAP DR
BU SHING”
10. Move “ F DOOR HANDLE” to “
R DOOR”
Downloaded from Fridge-Manual.com Manuals
18
Downloaded from Fridge-Manual.com Manuals
19
11. Attach the“ HINGE U” on the left.
12. Attach the“ F DOOR”
13. Reverse the position of “ HINGE
M” and
“ CAP SCREW HOLE”
1. Attach the“ R DOOR”
15. Attach the“ HINGE T” on the left of cabinet after assem bling to“R DOOR”
16. Reverse the position of “ COV ER
HINGE ” and “ COV ER CAB HARNESS”
11. EXPLODE DRAWING
Downloaded from Fridge-Manual.com Manuals
20
Downloaded from Fridge-Manual.com Manuals
21
12. PARTS LIST
NO PART NAME
1 SHELF GLAS AS
2 COVER GLAS C/C AS
3 CASE CHILD
4 DOOR CHILLED CASE
5 COVER VEGTB CASE
6 KNOB HUMIDITY
7
CASE VEGETABLE *L
CASE VEGETABLE *R
8 CASE ICING
9 CASE F D
CASE F B AS
10
CASE F C AS
11 CASE F A AS
12 V-PCB AS
13 KNOB R CONTROL
14 COVER MULTI DUCT
15 COVER MULTI DUCT
14 COVER MULTI DUCT
15 COVER MULTI DUCT
16 INSU MULTI DUCT
16 INSU MULTI DUCT
17 SOCKET LAMP AS
18 LAMP
19 WINDOW R
20 DECO M/DUCT COVER
21 SENSOR R AS
22 COVER *T HINGE
23 HINGE *T AS
24 SPECIAL BOLT C
25 COVER CAB HARNESS
26 ASSY CAB URT
27 SWITCH DOOR
28 BOX PCB
29 M-PCB AS
30 COVER PCB BOX
31 PIPE WI-CON AS
32 COVER HRNS*R
COVER HRNS*L
33 COVER BUSH
34 WINDOW FCP B
35 WINDOW FCP A
36 PANEL *F CONTROL
Downloaded from Fridge-Manual.com Manuals
3017839400
3011497900
3011181400
3011760500
3011497700
3013410800
3011181900
3011182000
3011163200
3011181800
3011184900
3011185000
3011184800
30143C6260
3013410900
3011495700
3011495600
3011495900
3011495800
3013353800
3013353900
3017903900
3013600700
3015510100
3011633200
3012731800
DMS1494310
DMS1494320
3012922600
3016004900
DMS1477510
DMS1477520
-
-
-
3011755200
3011762900
3010545300
DMS0545310
30143C6060
30143C7060
3011477600
DMS1477610
3014434500
3011477100
DMS1477110
3011477200
DMS1477210
3011498200
DMS1498210
3015510000
3015509900
3014234000
DMS4234010
PART CODE
MODEL
REMARK
366N 366A 396N 396A 416N 416A
2 2 3 3 3 3
11
1
1
1
1
1
1
1
1
-
1
1
1
-
-
-
1
-
1
1
-
1
1
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
-
-
1
1
-
-
1
1
1
1
1
-
-
11
1
1
1
1
1
1
1
1
1
1
1
1
-
-
-
-
1
-
-
-
1
1
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
1
1
-
1
1
1
1
-
-
11
1
1
-
1
1
1
1
1
-
1
1
-
1
1
-
-
-
1
1
2
1
1
-
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
-
-
1
1
-
-
1
1
1
1
1
1
-
11
1
1
-
1
1
1
1
1
1
1
1
-
1
-
1
-
-
-
-
2
1
1
-
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
1
1
-
1
1
1
1
1
-
1
1
1
1
1
1
1
1
-
-
1
1
-
-
1
1
1
1
1
-
1
-
-
1
1
2
1
1
-
1
1
2
1
1
1
1
1
1
1 NANO SILVER
1 NANO SILVER
1
2
1 NANO SILVER
1 NANO SILVER
1
-
-
-
-
1
BLUE MILKY
2 BLUE MILKY
1 BLUE MILKY
1
-
1
1
-
1
1
-
-
1
-
1
1
1
1 BLUE MILKY
1 BLUE
1
1
1
1
1
1 SNOW WHITE
1 03 SILVER
1
11 11
1 1 SNOW WHITE
1
-
1
-
03 SILVER
-
1
1 WHITE
1 03 SILVER
1
-
1 03 SILVER
1 SNOW WHITE
1 03 SILVER
1 SNOW WHITE
1
1 03 SILVER
1 SNOW WHITE
1 03 SILVER
1 SNOW WHITE
1 03 SILVER
1 SNOW WHITE
-
1
1 03 SILVER
1 SNOW WHITE
22
NO PART NAME
37 BUTTON F-CP
38 F-PCB AS
39 GASKET R DOOR AS
40 HANDLE R
3016304300
30143C6160
3012306600
3012306800
3012640000
DMS2640010
3011495200 41 COVER HNDL SCREW
42 SPECIAL SCREW
43 ASSY R DR A/S 366A SW
ASSY R DR A/S 366A SV
ASSY R DR A/S 366N SW
ASSY R DR A/S 366N SV
DMS1495210
3016033600
DMS0060000
DMS0060010
DMS0060100
DMS0060110
ASSY R DR A/S 396A 416A SW DMS0061000
ASSY R DR A/S 396A 416A SV DMS0061010
ASSY R DR A/S 396N 416N SW DMS0061100
ASSY R DR A/S 396N 416N SV DMS0061110
44 CAP DR BUSHING 3010967400
45 COVER DAIRY POCKET
46 POCKET DAIRY
47 POCKET R
48 GUIDE BOTTLE POCKET
DMS0967420
3011495000
3019025000
3019025200
3012523800
49 POCKET BOTL AS
50 POCKET MULTI AS
51 CAP HANDLE
3019026100
3019026200
52 HANDLE F
3010910000
DMS0910030
3012639800
DMS2639810
DMS0062000 53 ASSY F DR A/S 366 396 SW
ASSY F DR A/S 366 396 SV
ASSY F DR A/S 416 SW
DMS0062010
DMS0062100
ASSY F DR A/S 416 SV
54 GASKET F DOOR AS
55 CAP SCREW
56 CAP SCREW HOLE
57 COVER CAB BRACKET
58 HINGE *M
59 HINGE *U
60 FOOT ADJUSTING AS
61 BRACKET FAN MOTOR
62 MOTOR FAN AS
63 LOUVER F B
63 LOUVER F B
64 LOUVER F A
64 LOUVER F A
65 BUSHING FAN MOTOR
66 FAN
67 KNOB F LOUVER
68 EVAPORATOR AS
69 HEATER D AS
70 CAP DRAIN HOSE
DMS0062110
3012306500
3012306700
3010920200
DMS0920220
3010920300
3011494900
DMS1494910
3012908002
DMS2908201
3012101800
3010615600
3011804710
3018918900
3018919000
3018918700
3018918800
3010701800
3011801410
3013410700
3017045600
3012807651
3010919700
PART CODE
1
1
4
4
1
1
1
1
-
1
1
1
1
1
-
1
-
-
-
1
1
4
4
-
-
1
1
1
2
1
1
1
1
1
2
1
-
1
-
1
1
1
1
1
-
1
-
1
1
1
4
4
1
1
1
1
-
1
1
1
1
1
1
1
-
-
-
-
-
4
4
-
1
1
1
1
2
1
1
1
1
1
2
1
-
1
-
1
1
1
1
1
-
1
-
1
1
1
4
4
1
1
1
1
-
1
1
1
1
1
-
1
1
1
-
-
-
4
4
-
-
1
1
1
2
1
1
1
1
1
2
1
-
1
-
1
1
1
1
1
-
1
-
1
MODEL
REMARK
366N 366A 396N 396A 416N 416A
1
1
4
1
-
-
-
1
1
4
1
-
1
1
1
1
4
-
1
-
-
1
1
4
-
1
1
1
1
1
4
-
1
-
-
-
1
1
1
1 03 SILVER
1 SNOW WHITE
4 03 SILVER
1
1
4
4
1
1
1
1
-
1
1
1
1
1
-
1
-
-
1
-
-
4
4
1
-
1
1
1
2
1
1
1
1
1
2
1
-
1
-
1
1
1
1
1
-
1
-
1
1
1
4
4
-
1
1
-
1
1
1
1
1
1
1
1
-
-
-
-
-
4
4
-
1
1
1
1
2
1
1
1
1
-
2
1
1
-
1
1
1
1
1
1
1
1
1
-
4 SNOW WHITE
4
GRIP S-WHITE
GRIP SILVER
GRIP S-WHITE
GRIP SILVER
1 GRIP S-WHITE
1 GRIP SILVER
GRIP S-WHITE
GRIP SILVER
1 SNOW WHITE. SUBSTITUTE DMS0918301
1 03 SILVER
1 BLUE MILKY
1
1
1 BLUE MILKY
1 BLUE MILKY
1 BLUE MILKY
4 SNOW WHITE
4 03 SILVER
1 03 SILVER
1 SNOW WHITE
GRIP S-WHITE
GRIP SILVER
1 GRIP S-WHITE
1 GRIP SILVER
-
1
1 SNOW WHITE
1 03 SILVER
1
1 SNOW WHITE
1
1
1
2
1
1
1
1
-
2
1
1
-
1
1 03 SILVER
1
23
Downloaded from Fridge-Manual.com Manuals
NO PART NAME
71 CASE VAPORY
72 FIXTURE COMP
73 DRYER ASSY
74 COMPRESSOR
75 ABSORBER COMP
76 SCREW MACHINE
77 SPECIAL WASHER
78 PIPE CHARGE
79 HARNESS EARTH
80 BASE COMP
81 SPECIAL SCREW A
82 CAPACITOR RUN
83 SPECIAL WASHER R/C
84 SPECIAL NUT R/C
85 RELAY BOX
86 CLAMP CORD A
87 CLAMP CORD B
88 SWITCH P RELAY OL
89 SWITCH P RELAY PTC
90 HARNESS RELAY
91 COVER MECH HOUSING
92 SCREW TAPPING
93 CORD POWER AS
94 LOUVER F C
PART CODE
3011162700
3012005300
3016802203
DMS0A00100
3010103400
DMS1B00100
DMS1B00200
3014418211
3012735220
-
3016004300
DMS6402129
DMS6006510
DMS6006410
DMS0527900
DMS1200100
DMS1200200
DMS1A00100
DMS1C00100
3012731901
3011454100
7112401011
3011343340
3018920700
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
MODEL
366N 366A 396N 396A 416N 416A
1 1 1 1 1 1
1
4
2
1
1
1
1
4
2
1
1
1
1
4
2
1
1
1
1
4
2
1
1
1
1
4
2
1
1
1
1
4
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
REMARK
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1 COMMON
1
Downloaded from Fridge-Manual.com Manuals
24
13. PCB CONTROL FUNCTION
13.1. ERF-XXXA
NO
1.
FUNCTION CONTENTS
DISPLAY
1) VAC STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 1 TIME.
2) LOW STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 2 TIMES.
3) MID STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 3 TIMES.
4) HIGH STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 4 TIMES.
5) SUPER STEP LED ON: WHEN TEMP CONTROL S/W IS PRESSED 5 TIMES.
6) ERROR LED DISPLAY (ON MAIN PCB)
?FUNCTION DISPLAY
- D1 ERROR : LED is off & on one time.
- D2 ERROR : LED is off & on two times.
- R1 ERROR : LED is on & off one time.
- RT ERROR : LED is on & off two times.
- EP ERROR : LED is on & off continually
- DR ERROR : LED is on continually
- FORCED DEFROST OF CONDITION: HIGH, LOW led Lamps are on
- SHORT CIRCUIT OF CONDITION: SUPER, MIDDLE, VAC led Lamps are on
25
Downloaded from Fridge-Manual.com Manuals
2.
TEMPERATURE
ADJUSTMENT
&
CONTROL
1) TEMP. CONTROL SWITCH
1.1- TEMP. CONTROL
When TEMP CONTROL button is pressed, the led lamps MIDLE - HIGH -
SUPER - VAC -LOW - MIDDLE will be on in sequence.
TEMPERATURE will be set if the button doesn’t get pressed again within 5 sec
1.2- FORCED DEFROST: will be start when this button pushed for over 5 seconds continuously.
1.3- SHORT CIRCUIT OPERATION: will be started and stopped when this button pushed over 30 times.
2) TEMPERATURE CONTROL
2.1- COMP will be controlled by the on/off condition of each mode.
2.2- STEP DIFF of ROOM R : Vac/Low - 1.75 deg, Low/Middle - 0.7deg,
Mid/High - 1.05deg, High/Super - 1.4 deg
2.3- OFF point of ROOM R in MID position: -0.5°C
2.4- ON/OFF DIFF of ROOM R: 3ºC
4.95¡ É
3.2¡ É
2.5¡É
1.45¡É
0.05 ¡ É O N - í
1.95 ¡É
0.2¡ É
-0.5¡É
-1.55¡ É
OFF - í
-2.95¡É
3.
VACATION
3) FORCED DEFROST
3.1- Defrost mode will be Started independent of the cycle.
3.2- The flow is same as the general defrost mode flow.
4) SHORT CIRCUIT OPERATION
4.1 - COMP & FAN will be on independent of the operation condition.
4.2- The time limit of SHORT CIRCUIT OPERATION: 60 hrs
- Press TEMP. CONTROL SWITCH and make VAC led lamp on.
ON POINT: 4.95°C
OFF POINT: 1.95°C
26
Downloaded from Fridge-Manual.com Manuals
4.
5.
Determination of
DEFROST
6.
SUPER
DEFROST
MODE
- Press TEMP. CONTROL button and make SUPER led lamp on.
ON POINT: 0.05°C
OFF POINT: -2.95°C
1) Starting condition of Defrost Mode
1.1- When accumulated running time of comp. Is 8, 10, 12, 18, 30hrs.
1.2- After Checking the condition ‘1.1’ if total time ( COMP on time + COMP off time) is more than 24, 36, 48, 72hrs, then defrost mode starts immediately.
RT-SENSOR
RT 29°C Up
Accumulated running time of
Door Open
8HR
COMP
Door Close
18HR
Total running time of COMP
Door Open
24HR
Door Close
36HR
20<RT< 28°C
15<RT< 19°C
RT 14°C Down
12HR
8HR
8HR
30HR
12HR
10HR
48HR
24HR
24HR
72HR
36HR
36HR
1) General Defrost Mode
1.1- Start: By determination of defrost
1.2- Process: General operation - Heater on – Pause (6min) - General operation
-Heater defrosts: When the temperature at D-sensor is over 10°C, heater turns off.
-Limit time: 80 min (30 min on D SENSOR ERROR)
2) Forced Defrost Mode
2.1- Start: by press TEMP. CONTROL button for 5 seconds continuously.
2.2- Process: same as General Defrost Mode
-Heater is supposed to be on Initial 30 seconds. (for TEST)
2.3- Display : led lamps ‘LOW’ ‘HIGH’ is on.
7.
8.
INITIAL
DEFROST
PREVENTION
OF COMP.
RESTART
1) When power is on, if the temperature at the D-sensor is under 3.5°C, then General
Defrost Mode starts.
2) When initial defrost mode starts, heater will be on directly and defrost mode will be started.
COMP. doesn’t work after COMP. turns off even though R-sensor is on condition. (This is to protect comp.)
1) General operation : The COMP can’t be on within 6 min.
2) Operation of LOW RT : The COMP can’t be on within 40 min.
Downloaded from Fridge-Manual.com Manuals
27
- ERROR DISPLAY
- When error happens, it is displayed on led lamp.(Main PCB LED 1)
1) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT)
1.1- DISPLAY : On & off one time while LED is on.
1.2- CONTROL : Controlled by the condition of RT
(Unit : min)
RT-S TEMP RT-S ERROR 19ºC Down 20ºC Up
9.
ERROR
DISPLAY
&
CONTROL
10.
SHORT CIRCUIT
TEST
COMP. Operating TIME (ON / OFF) 20 / 30 15 / 35 22 / 28
1.3- CANCEL : when R-SENSOR is working normally.
2) D1 ERROR (It happens when D-SENSOR is OPEN or SHORT)
2.1- DISPLAY : On & off one time while LED is off.
2.2- CONTROL : Return to the limit defrost time of Defrost (30 min)
3) D2 ERROR (It happens when heater is off by time - 80 min).
3.1- DISPLAY : On & off two times while LED is off.
3.2- CONTROL : Return to next limit defrost time (80 min)
4) RT ERROR (It happens when RT-SENSOR is OPEN or SHORT)
4.1- DISPLAY : On & off two times while LED is on.
4.2- CONTROL : The system is normally operating but the controlling by RT-
SENSOR doesn’t work.
4.3- CANCEL : when RT-SENSOR is working normally.
5) DR ERROR
5.1- Display : LED is on continuously
5.2- Control : Deletion of function related door switch sensing
5.3- If door switch (open & close) is sensed, the error is terminated automatically
1) START : by pressing REF.TEMP. CONTROL button 30 times continuously.
2) CANCEL : by pressing TEMP CONTROL button 30 times continuously.
Cf. the system generally operates after the limit t ime 60 hrs. passes.
3) DISPLAY : LED lamps are SUPER, MIDDLE, VAC on
4) CONTROL : COMP & FAN will be on independent of the operating condition.
(There is no defrost mode on this test.)
11.
FUNCTION
OF
TIME REDUCTION
1) HOW TO REDUCE: (There is no FAST KEY on PCB for MP.)
1 min : Click FAST KEY one time
30 min : If you press FAST KEY continuously, you can reduce 30 minutes on each second.
2) Practical Use : Can be applied to reduce needless time on test.
EX) function of stop for 6 min
28
Downloaded from Fridge-Manual.com Manuals
12. POWER ON / OFF
1) START : Press POWER button
2) CANCELATION : Press POWER button again
3) DISPLAY
- START : All LED lamps are off and power is off.(COMP, Heater, Lamp of Room)
- CANCEL : Return to the last condition(dial)
13.
MEMORY SAVING
ON POWER
FAILURE
-After power failure or momentary power failure happens, if power is back on, the mode will be returned on last condition.
14. EEPROM CLEAR
-Make EEPROM clear r ight before shipping (set the initial mode)
-How to clear : press REF.TEMP. button 5 time with pressing POWER button.
15.
FUNCTION
OF
LOW ROOM
TEMPERATURE
1) Condition of LOW RT TEMP :
1.1- LOW RT A : RT SENSOR < 14ºC
1.2- LOW RT B : 15ºC > RT-S < 19ºC
2) Control
2.1- When Comp. is on, R-SENSOR HTR is off.
When it passes 6 min after COMP. is off, R-SENSOR HTR is on until COMP is on.
2.2- COMP. Can’t be on within 40 min. after COMP. is off.
2.3- When it is not the Mode of LOW ROOM TEMP. or RT-SENSOR is on
ERROR(open or short), R-SENSOR HTR is off.
- LOW RT TEMP A Condition
- R-SENSOR Operating Temperature 1ºC up
- LOW RT TEMP B Condition
R-SENSOR Operating Temperature
Downloaded from Fridge-Manual.com Manuals
29
1) R-SENSOR OFF POINT can be adjusted by changing the input voltage of MICOM 26 pin.
2) The default of input voltage is 0V.
3) The changed OFF POINT is base OFF POINT + OFF POINT of input voltage.
16.
R-SENSOR
OFF POINT
ADJUSTING
OPTION
4) The change of R-SENSOR OFF POINT depend on the input voltage of MICOM
MICOM
0 1.0 1.5 2.0 2.5 3.7
Input (V)
OFF
POINT
Variation
(ºC)
-0.5ºC
(DEF)
1.0ºC down
2.0ºC down
3.0ºC down
1.0ºC
up
2.0ºC up
5.0
3.0ºC up
R26, R27
Resistan ce
(kOhms)
Jumper adoption
R27 : 40
R26 : 10
R27:23.3
R26:10
R27:15
R26:10
R27:10
R26:10
R27:3.5
R26:10
R27:10
R26:DEL
5) APPLICATION (MAIN PCB)
5.1- GENERAL: MICOM 26 port - 0V
5.2- DELETE J2 (CHANGING R OFF POINT 1DEG UP) : MICOM 26 port – 2.5V
LOW COOLING
OPTION
- R-SENSOR OFF POINT ADJUSTMENT (1 DEG. DOWN)
- J1 DELETION on LOW COOLING OPTION
Default resistance (31.4 Kohms) + 1.5 kohms = 32.9 Kohms
Operating on condition that R-SENSOR OFF point goes down 1ºC.
30
Downloaded from Fridge-Manual.com Manuals
13.2. ERF-XXXN
NO FUNCTION
1.
CONTENTS
DISPLAY
- Temperature control of Refrigerator
Maximum angle clockwise : Temperature setting for SUPER
Maximum angle counter-clockwise : Temperature setting for VACATION
Maximum rotation : 280±10°
Minimum Step Difference : 0.7 deg/28°
Total step Difference : 6.3 deg
ERROR LED DISPLAY (ON MAIN PCB)
DISPLAY ¦++Ù LED +ÔÀ-ã-ó
?FUNCTION DISPLAY
- D1 ERROR : LED is off & on one time.
- D2 ERROR : LED is off & on two times.
- R1 ERROR : LED is on & off one time.
- RT ERROR : LED is on & off two times.
- DR ERROR : LED is on continually
- Buzzer sounds if any button of M-PCB(SW2) is pushed.
- FORCED DEFROST OF CONDITION : Button of M-PCB(SW2) is pushed 1 time.
31
Downloaded from Fridge-Manual.com Manuals
1) TEMPERATURE ADJUSTMENT
1.1- TEMPERATURE ADJUSTMENT
TEMP CONTROL DIAL is rotated VAC , LOW, MIDDLE, HIGH, SUPER.
TEMPERATURE will be set if the Dial doesn’t get rotated again within 5 sec
1.2- FORCED DEFROST : Button of M-PCB(SW2) is pushed 1 time.
1.3- SHORT CIRCUIT OPERATION : Button of M-PCB(SW2) is pushed 2 times.
2 )TEMPERATURE CONTROL
2.1- COMP will be controlled by the on/off point of R-Sensor at each mode.
2.2- STEP DIFF of ROOM R : 1.4 deg
2.3- Middle OFF point of ROOM R : -0.15°C
2.4- ON/OFF DIFF of ROOM R : 3 deg
2.
TEMPERATURE
ADJUSTMENT
&
CONTROL
5.65¡ É
4.25¡É
2.85¡É
1.45¡É
0.05 ¡ É O N - í
2.65 ¡É
1.25¡ É
-0.15¡É
-1.55¡ É
OFF - í
-2.95¡É
3 )FORCED DEFROST
3.1- Defrost mode will be Started independent of the cycle.
3.2- The flow is same as the general defrost mode flow.
4 )SHORT CIRCUIT OPERATION
4.1- COMP & FAN will be on independent of the operation condition.
4.2-The time limit of SHORT CIRCUIT OPERATION: 60 hrs
3.
VACATION
- Rotate TEMP. CONTROL Dial and make Vacation Location.
ON POINT: 5.65°C
OFF POINT: 2.65°C
32
Downloaded from Fridge-Manual.com Manuals
4. SUPER
5.
DETERMINATION
OF
DEFROST
- Rotate TEMP. CONTROL Dial and make Super Location
ON POINT: 0.05°C
OFF POINT: -2.95°C
- Starting condition of Defrost Mode
- When accumulated running time of comp. is 8, 10, 12, 18, 30hrs.
- After Checking the condition ‘2.1’ if total time(COMP on time + COMP off time) is more than 24, 48, 36, 72hrs, then defrost mode starts immediately.
RT-SENSOR
RT 29°C Up
Accumulated running time of
Door Open
8HR
COMP
Door Close
18HR
Total running time of COMP
Door Open
24HR
Door Close
36HR
20<RT< 28°C
15<RT< 19°C
RT 14°C Down
12HR
8HR
8HR
30HR
12HR
10HR
48HR
24HR
24HR
72HR
36HR
36HR
6.
DEFROST
MODE
1) General Defrost Mode
1.1- Start : By determination of defrost
1.2- Process : General operation - Heater on - Pause (6min) - General operation
-Heater defrost : When the temperature at D-sensor is over 10°C, heater turns off.
-Limit time : 80 min (30 min on D sensor error)
2) Forced Defrost Mode
2.1 Start : Button of M -PCB(SW2) is pushed 1 Time.
2.2 Process : same as General Defrost Mode
-Heater is supposed to be on Initial 30 seconds. (for TEST)
7.
8.
INITIAL
DEFROST
PREVENTION
OF COMP.
RESTART
1) When power is on, if the temperature at the D-sensor is under 3.5°C, then General
Defrost Mode starts.
2) When initial defrost mode starts, heater will be on directly and defrost mode will be started.
COMP. doesn’t work after COMP. turns off even though R-sensor is on condition. (This is to protect comp.)
1) General operation : The COMP can’t be on within 6 min.
2) Operation of LOW RT : The COMP can’t be on within 40 min.
Downloaded from Fridge-Manual.com Manuals
33
9.
ERROR
DISPLAY
&
CONTROL
10.
SHORT CIRCUIT
TEST
* ERROR DISPLAY a. When error happens, it is displayed on led lamp.(Main PCB LED 1)
1) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT)
1.1- DISPLAY : On & off one time while LED is on.
1.2- CONTROL : Controlled by the condition of RT
(Unit : min)
RT-S TEMP RT-S ERROR 19ºC Down 20ºC Up
COMP. Operating TIME (ON / OFF) 20 / 30 15 / 35 22 / 28
1.3- CANCEL : when R-SENSOR is working normally.
2) D1 ERROR (It happens when D-SENSOR is OPEN or SHORT)
2.1- DISPLAY : On & off one time while LED is off.
2.2- CONTROL : Return to the limit defrost time of Defrost (30 min)
3) D2 ERROR (It happens when heater is off by time ? 80 min).
3.1- DISPLAY : On & off two times while LED is off.
3.2- CONTROL : Return to next limit defrost time (80 min)
4) RT ERROR (It happens when RT-SENSOR is OPEN or SHORT)
4.1- DISPLAY : On & off two times while LED is on.
4.2- CONTROL : The system is normally operating but the controlling by RT-
SENSOR doesn’t work.
4.3- CANCEL : when RT-SENSOR is working normally.
5) DR ERROR
5.1- Display : LED is on continuously
5.2- Control : Deletion of function related door switch sensing
5.3- If door switch(open & close) is sensed, the error is terminated automatically.
1) START : Button of M-PCB(SW2) is pushed 2 times and SW1 6 times .
2) CANCEL : Button of M-PCB(SW2) is pushed 1 time.
Cf. the system generally operates after the limit time 60 hrs. passes.
3) CONTROL : COMP & FAN will be on independent of the operating condition.
(There is no defrost mode on this test.)
11.
FUNCTION
OF
TIME
REDUCTION
1) HOW TO REDUCE: (There is no FAST KEY on PCB for MP.)
1 min : Click FAST KEY on e time
30 min : If you press FAST KEY continuously, you can reduce 30 minutes on each second.
2) Practical Use : Can be applied to reduce needless time on test.
EX) function of stop for 6 min
34
Downloaded from Fridge-Manual.com Manuals
15.
FUNCTION
OF
LOW ROOM
TEMPERATURE
1) Condition of LOW RT TEMP :
1.1- LOW RT A : RT SENSOR <14ºC
1.2- LOW RT B : 15ºC > RT-S < 19ºC
2) Control
2.1- When Comp. is on, R-SENSOR HTR is off.
When it passes 6 min after COMP. is off, R-SENSOR HTR is on until COMP is on.
2.2- COMP. can’t be on within 40 min. after COMP. is off.
2.3- When it is not the Mode of LOW ROOM TEMP. or RT-SENSOR is on
ERROR(open or short), R-SENSOR HTR is off.
- LOW RT TEMP A Condition
R-SENSOR Operating Temperature 1ºC up
- LOW RT TEMP B Condition
R-SENSOR Operating Temperature
16. 1) R-Sensor OFF Point can be adjusted by changing the input voltage of Micom 26 pin.
2) The default of input voltage is 0V.
3) The changed OFF Point is base OFF POINT + OFF POINT of input voltage.
R-SENSOR
OFF POINT
ADJUSTING
OPTION
4) The change of R-SENSOR OFF POINT depend on the input voltage of MICOM
MICOM
0 1.0 1.5 2.0 2.5 3.7
Input (V)
OFF
POINT
Variation
(ºC)
R26, R27
Resistan ce
(KOhms)
-0.15ºC
(DEF)
Jumper adoption
1.0
Down
R27 : 40
R26 : 10
2.0
Down
R27:23.3
R26:10
3.0
Down
R27:15
R26:10
1.0
Up
R27:10
R26:10
2.0
Up
R27:3.5
R26:10
5.0
3.0
Up
R27:10
R26:DEL
35
Downloaded from Fridge-Manual.com Manuals
5) APPLICATION (MAIN PCB)
5.1- GENERAL: MICOM 26 port - 0V
5.2- DELETE J2 (CHANGING R OFF POINT 1DEG UP) : MICOM 26 port – 2.5V
LOW COOLING b.
OPTION a. R-SENSOR OFF POINT ADJUSTMENT (1 DEG. DOWN)
J1 DELETION on LOW COOLING OPTION
Default resistance (31.4 KOhms) + 1.5 KOhms = 32.9 KOhms
Operating on condition that R-SENSOR OFF point goes down 1ºC.
Downloaded from Fridge-Manual.com Manuals
36
DAEWOO ELECTRONICS MANUFACTURING ESPAÑA S.A
Polígono industrial de Júndiz
C/Zurrupitieta 27, 01015 Vitoria, Spain
Tel: 00 34 945292292
Fax:00 34 945290965
Downloaded from Fridge-Manual.com Manuals