Agilent Performance dc Power Supplies

speed and accuracy for test optimization

Multiple-Output:

40 W-105 W GPIB

6621A-6624A, 6627A

Fast up and down programming

Proven reliability keeps test systems running

Easy to integrate into a system

Extensive protection for DUTs

S p e c i f i c a t i o n s

(at 0 ˚ to 55 ˚ C unless otherwise specified)

40 W 40 W 80 W 80 W 105 W output output output output output

Two, three, or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses. Most of the outputs also provide dual ranges, for more current at lower voltage levels. The outputs can be connected in parallel or series to further increase the flexibility that these products offer the system designer.

Programming is done using industry standard SCPI commands.

Test system integration can be further simplified be using the

VXIPlug&Play drivers. These power supplies help reduce test time with fast up and down programming, which is enhanced by an active downprogrammer which can sink the full rated current.

Output power

Output combinations for each model

(total number of outputs)

Low-range volts, amps 0 to 7 V,

0 to 5 A

0 to 20 V,

0 to 2 A

0 to 7 V,

0 to 10 A

0 to 20 V,

0 to 4 A

0-35 V,

0-3 A

High range volts, amps 0 to 20 V, 0 to 50 V, 0 to 20 V, 0 to 50 V, —

0 to 2 A 0 to 0.8 A 0 to 4 A 0 to 2 A —

6621A (2) — 2 —

6622A (2) — — — 2

6623A (3) 1 1 1 —

6624A (4) 2 2 —

Programming accuracy

6627A (4) — 4 — —

6623A(3)

Special Order Option J03

— 2

— — 1

Readback accuracy

(at 25°C ±5°C)

Voltage 19 mV

+ 0.06%

50 mV

+ 0.06%

Current 50 mA 20 mA

+ 0.16% + 0.16%

Voltage 20 mV

+ 0.05%

50 mV

+ 0.05%

19 mV

+ 0.06%

100 mA

+ 0.16%

20 mV

+ 0.05%

50 mV

+ 0.06%

40 mA

+ 0.16%

50 mV

+ 0.05%

35 mV

+ 0.06%

30 mA

+ 0.16%

35 mV

+ 0.05%

+Current 10 mA

+ 0.1%

-Current 25 mA

+ 0.2%

4 mA

+ 0.1%

8 mA

+ 0.2%

20 mA

+ 0.1%

50 mA

+ 0.2%

8 mA

+ 0.1%

20 mA

+ 0.2%

6 mA

+ 0.1%

15 mA

+ 0.2%

Ripple and noise

(peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz)

Load regulation

Load cross regulation

Line regulation

Constant voltage rms peak-to-peak

500 µV

3 mV

Constant current rms 1 mA

Voltage 2 mV

Current

Voltage

1 mA

1 mV

500 µV

3 mV

1 mA

2 mV

0.5 mA

2.5 mV

500 µV

3 mV

1 mA

2 mV

2 mA

1 mV

500 µV

3 mV

1 mA

2 mV

1 mA

2.5 mV

500 µV

3 mV

1 mA

2 mV

2 mA

N/A

Current 1 mA 0.5 mA 2 mA 1 mA N/A

Voltage 0.01% 0.01% 0.01% 0.01% 0.01%

+ 1 mV + 1 mV + 1 mV + 1 mV + 1 mV

Current 0.06% 0.06% 0.06% 0.06% 0.06%

+ 1 mA + 1 mA + 1 mA + 1 mA + 1 mA

Transient response time Less than 75 µs for the output to recover to within 75 mV of nominal value following a load change within specfications

Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power

55

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

Multiple-Output: 40 W-105 W GPIB

(Continued)

S p e c i f i c a t i o n s

(at 0 ˚ to 55 ˚ C unless otherwise specified)

40 W 40 W 80 W 80 W 105 W output output output output output

Supplemental Characteristics for all model numbers

dc Floating Voltage: All outputs can be floated up to ±240 Vdc from chassis ground

Remote Sensing: Up to 1 V drop per load lead. The drop in the load leads is subtracted from the voltage available for the load.

Command Processing Time: 7 ms typical with front-panel display disabled

Down Programming: Current sink limits are fixed approximately 10% higher than source limits for a given operating voltage above 2.5 V

Input Power: 550 W max., 720 VA max.

GPIB Interface Capabilities: SH1, AH1, T6,

L4, SR1, RL1, PP1, DC1, DT0.

Regulatory Compliance: Listed to UL1244; conforms to IEC 61010-1; carries the CE mark.

Size: 425.5 mm W x 132.6 mm H x

497.8 mm D (16.75 in x 5.22 in x 19.6 in)

See page 103 for more details

Weight: Net, 17.4 kg (38 lb); shipping,

22.7 kg (50 lb)

Warranty Period:

One year

Supplemental Characteristics

Average programming resolution

OVP

(Non-warranted characteristics determined by design and useful in applying the product)

Voltage 6 mV 15 mV

Current

Output programming response time

(time to settle within 0.1% of full scale output, after Vset command has been processed)

25 mA

100 mV

2 ms

10 mA

250 mV

6 ms

6 mV 6 mV

20 mV (high) 20 mV (high)

10.5 mV

50 mA 50 mA

20 mA (high) 20 mA (high)

15 mA

100 mV 2 50 mV

2 ms 6 ms

175 mV

6 ms

Ordering Information

Opt 100 87 to 106 Vac, 47 to 66 Hz Input,

6.3 A (Japan only)

Opt 120 104 to 127 Vac, 47 to 63 Hz

Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A

Opt 240 209 to 250 Vac, 47 to 66 Hz, 3.0 A

Opt 750 Relay Control and DFI/RI

Opt S50 similar to option 750, however the remote inhibit does not latch

* Opt 908 Rack-mount Kit (p/n 5062-3977)

* Opt 909 Rack-mount Kit w/Handles

(p/n 5063-9221)

Opt 0L2 Extra Standard

Documentation Package

Opt 0B3 Service Manual

Opt 0B0 No documentation package

* Support rails required

Accessories

p/n 1494-0059 Rack Slide Kit

E3663A Support rails for

Agilent rack cabinets

Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power

56

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

Precision Multiple-Output:

25 W-50 W GPIB

Precise V & I programming and readback

Fast up and down programming

Extensive protection for DUTs

Easy to integrate into a system

6625A, 6626A, 6628A, 6629A

S p e c i f i c a t i o n s

(at 0 ˚ to 55 ˚ C unless otherwise specified)

25 W output 50 W output

Two or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses. Dual ranges allow for more current at lower voltage levels.

The outputs can be connected in parallel or series to further increase the flexibility that these products offer the system designer. Programming is done using industry standard SCPI commands and test system integration can be further simplified be using the

VXIPlug&Play drivers. These power supplies help reduce test time with fast up and down programming, which is enhanced by the active down-programmer which can sink the full rated current.

These power supplies are very useful on the R&D bench. The accuracy of both the programming and the measurement systems allow precise control and monitoring of prototype bias power. The extensive protection features protect valuable prototypes, including very fast CV/CC crossover. The power supply can be controlled from either the front panel keypad or, for automated testing, from the GPIB.

Output power Low-range volts, amps

High range volts, amps

0 to 7 V, 0 to 15 mA 0 to 16 V, 0 to 200 mA

0 to 50 V, 0 to 500 mA 0 to 50 V, 0 to 1 A or

0 to 16 V, 0 to 2 A

Output combinations for each model

(total number of outputs)

Programming accuracy

(at 25°C ±5°C)

Readback accuracy

(at 25°C ±5°C)

6625A (2) Precision

6626A (4) Precision

6628A (2) Precision

6629A (4) Precision

Voltage

Current

Voltage

+/-Current

1 1

2 2

— 2

— 4

1.5 mV + 0.016% (low) 3 mV + 0.016% (low)

10 mV + 0.016% (high) 10 mV + 0.016% (high)

15 µA + 0.04% (low) 185 µA + 0.04% (low)

100 µA + 0.04% (high) 500 µA + 0.04% (high)

0.016% + 2 mV (low) 0.016% + 3.5 mV (low)

0.016% + 10 mV (high) 0.016% + 10 mV (high)

0.03% + 15 µA (low) 0.04% + 250 µA (low)

0.03% + 130 µA (high) 0.04% + 550 µA (high)

Ripple and noise

(peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz)

Constant voltage rms peak-to-peak

500 µV

3 mV

500 µV

3 mV

Load regulation

Load cross regulation

Line regulation

Constant current rms

Voltage

Current

Voltage

Current

Voltage

Current

0.1 mA

0.5 mV

0.005 mA

0.25 mV

0.005 mA

0.5 mV

0.005 mA

0.1 mA

0.5 mV

0.01 mA

0.25 mV

0.01 mA

0.5 mV

0.01 mA

Less than 75 µs for the output to recover to within

75 mV of nominal value following a load

Transient response time change within specfications

Supplemental Characteristics

Average programming resolution Voltage

(Non-warranted characteristics determined by design and useful in applying the product)

25-watt output 50-watt output

460 µV (low) 1 mV (low)

3.2 mV (high)

1 µA (low)

3.2 mV (high)

13 µA (low) Current

OVP

33 µA (high)

230 mV

Output programming response time 6 ms

(time to settle within 0.1% of full scale output, after Vset command has been processed)

131 µA (high)

230 mV

6 ms

Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power

57

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

Precision Multiple-Output: 25 W-50 W GPIB

(Continued)

Supplemental Characteristics for all model numbers

Ordering Information

dc Floating Voltage: All outputs can be floated up to ±240 Vdc from chassis ground

Remote Sensing: Up to 10 V drop per load lead. The drop in the load leads is subtracted from the voltage available for the load.

Command Processing Time: 7 ms typical with front-panel display disabled

Input Power: 550 W max., 720 VA max.

GPIB Interface Capabilities: SH1, AH1, T6,

L4, SR1, RL1, PP1, DC1, DT0, C0, E1.

Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1.

Size: 425.5 mm W x 132.6 mm H x

497.8 mm D (16.75 in x 5.22 in x 19.6 in)

See page 103 for more details

Weight: 6626A, 6629A: Net, 17.4 kg (38 lb); shipping, 22.7 kg (50 lb) 6625A, 6628A:

Net, 15.5 kg (34 lb); shipping, 20.8 kg (46 lb)

Warranty Period:

One year

Opt 100 87 to 106 Vac, 47 to 66 Hz Input,

6.3 A (Japan only)

Opt 120 104 to 127 Vac, 47 to 63 Hz

Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A

Opt 240 209 to 250 Vac, 47 to 66 Hz, 3.0 A

Opt 750 Relay Control and DFI/RI

Opt S50 Similar to option 750, however the remote inhibit does not latch

* Opt 908 Rack-mount Kit (p/n 5062-3977)

* Opt 909 Rack-mount Kit w/Handles

(p/n 5063-9221)

Opt 0L2 Extra Standard

Documentation Package

Opt 0B3 Service Manual

Opt 0B0 No documentation package

* Support rails required

Accessories

p/n 1494-0059 Rack Slide Kit

E3663AC Support rails for Agilent rack cabinets

Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power

58

Your Requested Excerpt from the Agilent Power Products Catalog

The preceding page(s) are an excerpt from the 2002-2003 Power Products Catalog.

We hope that these pages supply the information that you currently need.

If you would like to have further information about the extensive selection of

Agilent dc power supplies, ac sources, and dc electronic loads, please visit www.agilent.com/find/power to print a copy of the complete Power Products catalog, or to request that a copy be sent to you. You will also find a lot of other useful information on this web site.

To see a copy of the user’s guide, please visit our Web site at www.agilent.com/find/manuals

By internet, phone, or fax, get assistance with all your test & measurement needs

Online assistance: www.agilent.com/find/assist

In the full Power Products Catalog, you will find that Agilent offers much more than basic power generation. If you need basic, clean, power for your lab bench, it’s there. But in each product category, we’ve also integrated the capabilities that you need for a complete power solution, including extensive measurement and analysis capabilities.

Please give us a call at your local Agilent Technologies sales office, or call a regional office listed below, for assistance in choosing or using

Agilent power products.

Keep up to date with Agilent’s Test and Measurement Email Updates

As an Email Update subscriber, you will receive periodic customized email updates that match the areas of interest that you have specified. Your update will include products and services, applications and support information, events, and promotions. Sign up today at www.agilent.com/find/emailupdates .

Check off dc power supplies, ac power sources or electronic loads on your registration form, and we will promptly let you know what’s new in power products! Our Privacy Statement at www.agilent.com/go/privacy describes our commitment to you regarding your privacy.

Phone or Fax

United States:

(tel)

1 800 829 4444

Canada:

(tel) 1 877 894 4414

(fax) (905) 282-6495

China:

(tel) 800-810-0189

(fax) 1-0800-650-0121

Europe:

(tel) (31 20) 547 2323

(fax) (31 20) 547 2390

Japan:

(tel) (81) 426 56 7832

(fax) (81) 426 56 7840

Korea:

(tel) (82-2) 2004-5004

(fax) (82-2) 2004-5115

Latin America:

(tel) (305) 269 7500

(fax) (305) 269 7599

Taiwan:

(tel) 080-004-7866

(fax) (886-2) 2545-6723

Other Asia Pacific Countries:

(tel) (65) 375-8100

(fax) (65) 836-0252

Email: [email protected]

Product specifications and descriptions in this document subject to change without notice.

Agilent Technologies

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement