Agilent Performance dc Power Supplies
speed and accuracy for test optimization
Multiple-Output:
40 W-105 W GPIB
6621A-6624A, 6627A
Fast up and down programming
Proven reliability keeps test systems running
Easy to integrate into a system
Extensive protection for DUTs
S p e c i f i c a t i o n s
(at 0 ˚ to 55 ˚ C unless otherwise specified)
40 W 40 W 80 W 80 W 105 W output output output output output
Two, three, or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses. Most of the outputs also provide dual ranges, for more current at lower voltage levels. The outputs can be connected in parallel or series to further increase the flexibility that these products offer the system designer.
Programming is done using industry standard SCPI commands.
Test system integration can be further simplified be using the
VXIPlug&Play drivers. These power supplies help reduce test time with fast up and down programming, which is enhanced by an active downprogrammer which can sink the full rated current.
Output power
Output combinations for each model
(total number of outputs)
Low-range volts, amps 0 to 7 V,
0 to 5 A
0 to 20 V,
0 to 2 A
0 to 7 V,
0 to 10 A
0 to 20 V,
0 to 4 A
0-35 V,
0-3 A
High range volts, amps 0 to 20 V, 0 to 50 V, 0 to 20 V, 0 to 50 V, —
0 to 2 A 0 to 0.8 A 0 to 4 A 0 to 2 A —
6621A (2) — 2 —
6622A (2) — — — 2
6623A (3) 1 1 1 —
6624A (4) 2 2 —
—
—
—
—
Programming accuracy
6627A (4) — 4 — —
6623A(3)
Special Order Option J03
— 2
—
— — 1
Readback accuracy
(at 25°C ±5°C)
Voltage 19 mV
+ 0.06%
50 mV
+ 0.06%
Current 50 mA 20 mA
+ 0.16% + 0.16%
Voltage 20 mV
+ 0.05%
50 mV
+ 0.05%
19 mV
+ 0.06%
100 mA
+ 0.16%
20 mV
+ 0.05%
50 mV
+ 0.06%
40 mA
+ 0.16%
50 mV
+ 0.05%
35 mV
+ 0.06%
30 mA
+ 0.16%
35 mV
+ 0.05%
+Current 10 mA
+ 0.1%
-Current 25 mA
+ 0.2%
4 mA
+ 0.1%
8 mA
+ 0.2%
20 mA
+ 0.1%
50 mA
+ 0.2%
8 mA
+ 0.1%
20 mA
+ 0.2%
6 mA
+ 0.1%
15 mA
+ 0.2%
Ripple and noise
(peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz)
Load regulation
Load cross regulation
Line regulation
Constant voltage rms peak-to-peak
500 µV
3 mV
Constant current rms 1 mA
Voltage 2 mV
Current
Voltage
1 mA
1 mV
500 µV
3 mV
1 mA
2 mV
0.5 mA
2.5 mV
500 µV
3 mV
1 mA
2 mV
2 mA
1 mV
500 µV
3 mV
1 mA
2 mV
1 mA
2.5 mV
500 µV
3 mV
1 mA
2 mV
2 mA
N/A
Current 1 mA 0.5 mA 2 mA 1 mA N/A
Voltage 0.01% 0.01% 0.01% 0.01% 0.01%
+ 1 mV + 1 mV + 1 mV + 1 mV + 1 mV
Current 0.06% 0.06% 0.06% 0.06% 0.06%
+ 1 mA + 1 mA + 1 mA + 1 mA + 1 mA
Transient response time Less than 75 µs for the output to recover to within 75 mV of nominal value following a load change within specfications
Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power
55
Agilent Performance dc Power Supplies
speed and accuracy for test optimization
Multiple-Output: 40 W-105 W GPIB
(Continued)
S p e c i f i c a t i o n s
(at 0 ˚ to 55 ˚ C unless otherwise specified)
40 W 40 W 80 W 80 W 105 W output output output output output
Supplemental Characteristics for all model numbers
dc Floating Voltage: All outputs can be floated up to ±240 Vdc from chassis ground
Remote Sensing: Up to 1 V drop per load lead. The drop in the load leads is subtracted from the voltage available for the load.
Command Processing Time: 7 ms typical with front-panel display disabled
Down Programming: Current sink limits are fixed approximately 10% higher than source limits for a given operating voltage above 2.5 V
Input Power: 550 W max., 720 VA max.
GPIB Interface Capabilities: SH1, AH1, T6,
L4, SR1, RL1, PP1, DC1, DT0.
Regulatory Compliance: Listed to UL1244; conforms to IEC 61010-1; carries the CE mark.
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.22 in x 19.6 in)
See page 103 for more details
Weight: Net, 17.4 kg (38 lb); shipping,
22.7 kg (50 lb)
Warranty Period:
One year
Supplemental Characteristics
Average programming resolution
OVP
(Non-warranted characteristics determined by design and useful in applying the product)
Voltage 6 mV 15 mV
Current
Output programming response time
(time to settle within 0.1% of full scale output, after Vset command has been processed)
25 mA
100 mV
2 ms
10 mA
250 mV
6 ms
6 mV 6 mV
20 mV (high) 20 mV (high)
10.5 mV
50 mA 50 mA
20 mA (high) 20 mA (high)
15 mA
100 mV 2 50 mV
2 ms 6 ms
175 mV
6 ms
Ordering Information
Opt 100 87 to 106 Vac, 47 to 66 Hz Input,
6.3 A (Japan only)
Opt 120 104 to 127 Vac, 47 to 63 Hz
Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A
Opt 240 209 to 250 Vac, 47 to 66 Hz, 3.0 A
Opt 750 Relay Control and DFI/RI
Opt S50 similar to option 750, however the remote inhibit does not latch
* Opt 908 Rack-mount Kit (p/n 5062-3977)
* Opt 909 Rack-mount Kit w/Handles
(p/n 5063-9221)
Opt 0L2 Extra Standard
Documentation Package
Opt 0B3 Service Manual
Opt 0B0 No documentation package
* Support rails required
Accessories
p/n 1494-0059 Rack Slide Kit
E3663A Support rails for
Agilent rack cabinets
Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power
56
Agilent Performance dc Power Supplies
speed and accuracy for test optimization
Precision Multiple-Output:
25 W-50 W GPIB
Precise V & I programming and readback
Fast up and down programming
Extensive protection for DUTs
Easy to integrate into a system
6625A, 6626A, 6628A, 6629A
S p e c i f i c a t i o n s
(at 0 ˚ to 55 ˚ C unless otherwise specified)
25 W output 50 W output
Two or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses. Dual ranges allow for more current at lower voltage levels.
The outputs can be connected in parallel or series to further increase the flexibility that these products offer the system designer. Programming is done using industry standard SCPI commands and test system integration can be further simplified be using the
VXIPlug&Play drivers. These power supplies help reduce test time with fast up and down programming, which is enhanced by the active down-programmer which can sink the full rated current.
These power supplies are very useful on the R&D bench. The accuracy of both the programming and the measurement systems allow precise control and monitoring of prototype bias power. The extensive protection features protect valuable prototypes, including very fast CV/CC crossover. The power supply can be controlled from either the front panel keypad or, for automated testing, from the GPIB.
Output power Low-range volts, amps
High range volts, amps
0 to 7 V, 0 to 15 mA 0 to 16 V, 0 to 200 mA
0 to 50 V, 0 to 500 mA 0 to 50 V, 0 to 1 A or
0 to 16 V, 0 to 2 A
Output combinations for each model
(total number of outputs)
Programming accuracy
(at 25°C ±5°C)
Readback accuracy
(at 25°C ±5°C)
6625A (2) Precision
6626A (4) Precision
6628A (2) Precision
6629A (4) Precision
Voltage
Current
Voltage
+/-Current
1 1
2 2
— 2
— 4
1.5 mV + 0.016% (low) 3 mV + 0.016% (low)
10 mV + 0.016% (high) 10 mV + 0.016% (high)
15 µA + 0.04% (low) 185 µA + 0.04% (low)
100 µA + 0.04% (high) 500 µA + 0.04% (high)
0.016% + 2 mV (low) 0.016% + 3.5 mV (low)
0.016% + 10 mV (high) 0.016% + 10 mV (high)
0.03% + 15 µA (low) 0.04% + 250 µA (low)
0.03% + 130 µA (high) 0.04% + 550 µA (high)
Ripple and noise
(peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz)
Constant voltage rms peak-to-peak
500 µV
3 mV
500 µV
3 mV
Load regulation
Load cross regulation
Line regulation
Constant current rms
Voltage
Current
Voltage
Current
Voltage
Current
0.1 mA
0.5 mV
0.005 mA
0.25 mV
0.005 mA
0.5 mV
0.005 mA
0.1 mA
0.5 mV
0.01 mA
0.25 mV
0.01 mA
0.5 mV
0.01 mA
Less than 75 µs for the output to recover to within
75 mV of nominal value following a load
Transient response time change within specfications
Supplemental Characteristics
Average programming resolution Voltage
(Non-warranted characteristics determined by design and useful in applying the product)
25-watt output 50-watt output
460 µV (low) 1 mV (low)
3.2 mV (high)
1 µA (low)
3.2 mV (high)
13 µA (low) Current
OVP
33 µA (high)
230 mV
Output programming response time 6 ms
(time to settle within 0.1% of full scale output, after Vset command has been processed)
131 µA (high)
230 mV
6 ms
Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power
57
Agilent Performance dc Power Supplies
speed and accuracy for test optimization
Precision Multiple-Output: 25 W-50 W GPIB
(Continued)
Supplemental Characteristics for all model numbers
Ordering Information
dc Floating Voltage: All outputs can be floated up to ±240 Vdc from chassis ground
Remote Sensing: Up to 10 V drop per load lead. The drop in the load leads is subtracted from the voltage available for the load.
Command Processing Time: 7 ms typical with front-panel display disabled
Input Power: 550 W max., 720 VA max.
GPIB Interface Capabilities: SH1, AH1, T6,
L4, SR1, RL1, PP1, DC1, DT0, C0, E1.
Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1.
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.22 in x 19.6 in)
See page 103 for more details
Weight: 6626A, 6629A: Net, 17.4 kg (38 lb); shipping, 22.7 kg (50 lb) 6625A, 6628A:
Net, 15.5 kg (34 lb); shipping, 20.8 kg (46 lb)
Warranty Period:
One year
Opt 100 87 to 106 Vac, 47 to 66 Hz Input,
6.3 A (Japan only)
Opt 120 104 to 127 Vac, 47 to 63 Hz
Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A
Opt 240 209 to 250 Vac, 47 to 66 Hz, 3.0 A
Opt 750 Relay Control and DFI/RI
Opt S50 Similar to option 750, however the remote inhibit does not latch
* Opt 908 Rack-mount Kit (p/n 5062-3977)
* Opt 909 Rack-mount Kit w/Handles
(p/n 5063-9221)
Opt 0L2 Extra Standard
Documentation Package
Opt 0B3 Service Manual
Opt 0B0 No documentation package
* Support rails required
Accessories
p/n 1494-0059 Rack Slide Kit
E3663AC Support rails for Agilent rack cabinets
Power Products Catalog 2002-2003 For more detailed specifications see the product manual at www.agilent.com/find/power
58
Your Requested Excerpt from the Agilent Power Products Catalog
The preceding page(s) are an excerpt from the 2002-2003 Power Products Catalog.
We hope that these pages supply the information that you currently need.
If you would like to have further information about the extensive selection of
Agilent dc power supplies, ac sources, and dc electronic loads, please visit www.agilent.com/find/power to print a copy of the complete Power Products catalog, or to request that a copy be sent to you. You will also find a lot of other useful information on this web site.
To see a copy of the user’s guide, please visit our Web site at www.agilent.com/find/manuals
By internet, phone, or fax, get assistance with all your test & measurement needs
Online assistance: www.agilent.com/find/assist
In the full Power Products Catalog, you will find that Agilent offers much more than basic power generation. If you need basic, clean, power for your lab bench, it’s there. But in each product category, we’ve also integrated the capabilities that you need for a complete power solution, including extensive measurement and analysis capabilities.
Please give us a call at your local Agilent Technologies sales office, or call a regional office listed below, for assistance in choosing or using
Agilent power products.
Keep up to date with Agilent’s Test and Measurement Email Updates
As an Email Update subscriber, you will receive periodic customized email updates that match the areas of interest that you have specified. Your update will include products and services, applications and support information, events, and promotions. Sign up today at www.agilent.com/find/emailupdates .
Check off dc power supplies, ac power sources or electronic loads on your registration form, and we will promptly let you know what’s new in power products! Our Privacy Statement at www.agilent.com/go/privacy describes our commitment to you regarding your privacy.
Phone or Fax
United States:
(tel)
1 800 829 4444
Canada:
(tel) 1 877 894 4414
(fax) (905) 282-6495
China:
(tel) 800-810-0189
(fax) 1-0800-650-0121
Europe:
(tel) (31 20) 547 2323
(fax) (31 20) 547 2390
Japan:
(tel) (81) 426 56 7832
(fax) (81) 426 56 7840
Korea:
(tel) (82-2) 2004-5004
(fax) (82-2) 2004-5115
Latin America:
(tel) (305) 269 7500
(fax) (305) 269 7599
Taiwan:
(tel) 080-004-7866
(fax) (886-2) 2545-6723
Other Asia Pacific Countries:
(tel) (65) 375-8100
(fax) (65) 836-0252
Email: [email protected]
Product specifications and descriptions in this document subject to change without notice.